ClinicalTrials.gov
public full text
Public Domain
Central Vein Stenosis Due to Dialysis Catheter Insertion in Subclavian Compared to Jugular Vein
Central vein stenosis (CVS) is a well-known complication of central venous catheterization, especially after insertion of temporary hemodialysis catheters (tHDC). Incidence and prevalence differ between studies, and exact figures are hard to tell since proper venographies seldom are performed unless the patient is symptomatic. Most tHDC are placed in the jugular or femoral veins as catheters in the subclavian veins have been shown to result in CVS to a greater degree. However, some studies are equivocal and there are several advantages with the subclavian vein such as a lower risk for infectious and thrombotic complications, longer durability (thereby avoiding placement of a new catheter with repeated tissue trauma), increased comfort during insertion and use, less effect on blood flow if the patient moves the head, easier to mobilize. The studies on CVS incidence originate from the 1990s when ultrasound-guided insertions were unheard of and polyurethane catheters were prevalent. The investigators believe that there is less tissue trauma when using ultrasound guidance in real-time. Furthermore, CVS is less common when silicone catheters are used instead of polyurethane catheters. To avoid unnecessary vascular trauma and patient suffering, any pre-existing CVS should ideally be detected before cannulation attempts. A CT scan of the chest with IV contrast is preferred, but this exposes the patient to ionized radiation, is time-consuming and (although debated) may cause contrast-induced nephropathy. A brief ultrasound examination to verify central venous patency would be useful provided it is shown to have an adequate sensitivity for stenosis detection.
Conceptio Open Archive
Analyze & explore related research in Conceptio
Connect this record directly into your research workflow or AI agent. Explore citations across open repositories, query full text, and export structured proof bundles.
This document is indexed with metadata only: full text is not available in the archive for this record. Open the official source ↗
Related documents
- Immediate Complications According to Ultrasound-guided Central Venous Catheters Insertion Site: a Non-inferiority Randomized Clinical Trial#1093296
- Long-versus Short-Axis Ultrasound Guidance for Subclavian Vein Cannulation#1075364
- Reducing Hemodialysis Catheter Use in Prevalent Hemodialysis Patients#845214
- Dialysis Catheter Placement in Patients With Thoracic Central Venous Occlusion#914329
- Verification of the Correct Insertion of a Central Venous Catheter#862666
Record · ID 1029859
Retrieved via Conceptio: every document is proof-bundled with source, license, and retrieval metadata.
Retrieved via Conceptio: every document is proof-bundled with source, license, and retrieval metadata.
Bring this data into your agent: Connect via MCP or API · 20 free credits to start · no card required
Read the Docs → · View CLI source on GitHub · Conceptio Open Knowledge Archive
Read the Docs → · View CLI source on GitHub · Conceptio Open Knowledge Archive