The Efficacy and Safety Evaluation of 5G Tele-PCI Using R-OneTM
Patients with coronary artery disease requiring PCI treatment were enrolled in the study. All patients underwent PCI with the robotic R-OneTM System (R-One Vascular Robotics, Cathbot). The system was designed for coronary PCI and consists of 2 major components: the command unit and a bedside robot. The command unit is a radiation-shielded, mobile workstation that was positioned in the corner of the catheterization laboratory. The interventional cardiologist sits at the command unit and remotely performs the PCI using the console joysticks. Commands from the control console are delivered as electrical signals along a communication cable that runs from the control console to the robotic drive, on which a sterile cassette is placed. The cassette, which is loaded with the robot and connected to the guiding catheters, imposes axial and rotational forces on the intracoronary devices. Fluoro-scopic, electrocardiographic, and hemodynamic images are "slaved" to the duplicate monitors inside the cockpit, enabling visualization from a closer distance. After completion of diagnostic angiography, the guiding catheter was positioned at the ostium of the coronary artery and connected to the disposable cassette on the robotic drive. The guidewire was loaded into the cassette before starting the robotic-enhanced PCI. The treatment plan is decided by the doctor according to the patients' situation. All intracoronary devices were to be manipulated exclusively by the robotic system, with bailout to manual conversion when needed. The primary endpoints were clinical procedural success and device technical success. The necessary sample size for testing the endpoint of clinical and technical procedural success was calculated on the basis of the target value. The statistical analysis results show that the lower limit of the 95% confidence interval of the clinical success rate and the technical success rate of the operation is greater than 90% of the target value, and the invalid hypothes
Conceptio Open Archive
Analyze & explore related research in Conceptio
Connect this record directly into your research workflow or AI agent. Explore citations across open repositories, query full text, and export structured proof bundles.
This document is indexed with metadata only: full text is not available in the archive for this record. Open the official source ↗
Related documents
- Comparative Study of the Effectiveness of Three Access Routes for Implanting an Electronic Intracardiac Device#1046708
- Teknik Pemeriksaan Percutaneous Coronary Intervention (PCI) pada Kasus Stenosis Right Coronary Artery (RCA): Percutaneous Coronary Intervention (PCI) Examination Technique in Right Coronary Artery (RCA) Stenosis Cases#268963
- Teknik Pemeriksaan Percutaneous Coronary Intervention (PCI) pada Kasus Stenosis Right Coronary Artery (RCA): Percutaneous Coronary Intervention (PCI) Examination Technique in Right Coronary Artery (RCA) Stenosis Cases#268857
- Clinical Evaluation of the CADenceTM System in Detection of Coronary Artery Diseases#994405
- SHIELD II Clinical Investigation#917431
Record · ID 1031479
Retrieved via Conceptio: every document is proof-bundled with source, license, and retrieval metadata.
Retrieved via Conceptio: every document is proof-bundled with source, license, and retrieval metadata.
Bring this data into your agent: Connect via MCP or API · 20 free credits to start · no card required
Read the Docs → · View CLI source on GitHub · Conceptio Open Knowledge Archive
Read the Docs → · View CLI source on GitHub · Conceptio Open Knowledge Archive