ClinicalTrials.gov
public full text
Public Domain
Fluoroscopic, Contact Force and Local Impedance With Ultra-high Density Mapping Guided Radiofrequency Ablation Comparison for cavoTricuspid Isthmus dependenT Atrial fluttER: the FLUTTER Study
Catheter ablation is a first-line treatment for patients with cavotricuspid isthmus (CTI) dependent atrial flutter (AFL; also known as typical AFL), a common arrhythmia. This is done using radiofrequency (RF) catheters and single-procedure success is approximately 95%. Ablation is often done using one of three methods: 1. fluoroscopically, using X-rays to guide the operator to visualise catheter position within the heart. This method involves the most radiation exposure to patient and operator. Ablation is generally performed for a set time-period (eg. 30-60secs) to ensure each ablation lesion is successful. 2. using a 3-dimensional mapping system which allows the catheters to be magnetically located and visualised on a monitor without X-rays, and using "contact force" (CF) sensing catheters. This requires minimal X-ray use, and by ensuring a minimum degree of force between catheter tip and the heart before applying RF for a set time-period (eg. 30 seconds), operators can be more confident of successful lesions. 3. using an ultra-high density mapping system which uses magnetic tracking as above, but allows higher resolution visualisation of the cardiac electrical system with potential for improving procedure success; this has not yet been formally evaluated for AFL. Catheters using this method use "local impedance" (LI) instead of CF. This is a direct measure of heart tissue impedance with real-time changes during ablation. A minimum drop or plateau in the LI value during ablation allows confidence of lesion success, without the need to ablate for a pre-defined time-period. This could potentially reduce ablation time and subsequent complications, but has also not yet been formally compared to the above for this indication. This prospective randomised study aims to compare these three standard of care procedures to determine if differences in ablation metrics, efficacy and safety exist.
Conceptio Open Archive
Analyze & explore related research in Conceptio
Connect this record directly into your research workflow or AI agent. Explore citations across open repositories, query full text, and export structured proof bundles.
This document is indexed with metadata only: full text is not available in the archive for this record. Open the official source ↗
Related documents
- Ablation Index in Standard vs. High Power Radiofrequency Ablation for Typical Atrial Flutter: A Randomized Study (AITAF)#827671
- Noninvasive Cardiac Radioablation for Ventricular Tachycardia Refractory to Medication and Catheter Ablation#834339
- Real-Time Intracardiac Echocardiography for Ventricular Arrhythmia Ablation#802167
- Safety and Efficacy of Catheter Ablation of Idiopathic Ventricular Arrhythmias Arising From Cardiac Outflow Tracts#1093568
- Feasibility Study of the FARAPULSE™ Cardiac Ablation System Plus in the Treatment of Persistent Atrial Fibrillation(PersAFOne II)#836873
Record · ID 1088344
Retrieved via Conceptio: every document is proof-bundled with source, license, and retrieval metadata.
Retrieved via Conceptio: every document is proof-bundled with source, license, and retrieval metadata.
Bring this data into your agent: Connect via MCP or API · 20 free credits to start · no card required
Read the Docs → · View CLI source on GitHub · Conceptio Open Knowledge Archive
Read the Docs → · View CLI source on GitHub · Conceptio Open Knowledge Archive