ClinicalTrials.gov
public full text
Public Domain
FEA, Biomechanical and Clinical Study of R.O. Peritrochanteric Fractures With PFLP vs Cephalomedullary Nail.
Hip fractures are the second most common fracture regardless of age, while at the same time its incidence is on the rise and it is expected to keep increasing in the future. In addition, hip fractures oppose a serious problem for both patients and clinicians, as they are associated with high rates of morbidity, reduced quality of life, impeded independent functionality and higher institutionalization rates. Several osteosynthesis techniques have been proposed for surgical correction of hip fractures which can be grouped into 3 main categories: a) Dynamic Hip Screw (DHS) extramedullary systems, b) Proximal femoral nail N \[PN\] PFNA\], γ-nail \[GN\] or other implants) and (c) Dynamic Condylar Screw, Angled blade plates, Proximal Femur Locking Plate (PFLP). This study will compare the use of anatomical proximal femur locking plates ( PeriLock, Smith\& Nephew) with an intramedullary nailing system, one of the most common and literature supported implants for the reduction of reverse oblique intertrochanteric fractures, classified as A31- 1,3 according to AO. The study will include Biomechanical testing and finite element analysis of the implants in an experimental setup using artificial bones performed at the Laboratory of Technology and Strength of Materials of the Department of Mechanical Engineering and Aeronautics of the University of Patras. and a pilot, prospective, randomized clinical study in a sample of 30 patients divided into 2 groups, where comparison of perioperative and intraoperative data will be accessed. The purpose of this study is to evaluate the efficacy and mechanical stability as wells as the clinical and radiological parameters as well as quality-of-life indicators in patients with reverse oblique hip fractures The primary goal of to investigate whether there are statistically significant differences in the main radiological parameters (cut-out, misalignment of the femoral head, loss of alignment, defective posture, non-union), while The second
Conceptio Open Archive
Analyze & explore related research in Conceptio
Connect this record directly into your research workflow or AI agent. Explore citations across open repositories, query full text, and export structured proof bundles.
This document is indexed with metadata only: full text is not available in the archive for this record. Open the official source ↗
Related documents
- Undisplaced Femoral Neck Fractures 2 Hansson Pins or 3 Pins Interlocked in Plate (Pinloc) Using RSA#912184
- Fitmore Versus CLS Stem in Total Hip Arthroplasty. Bilateral One-stage Operations#901592
- Comparison of Gamma Nail Versus Dynamic Hip Screw for the Treatment of Unstable Intertrochanteric Fractures#1059872
- Evaluation of the Proximal Femoral Nail Antirotation With Cement Augmentation in Osteoporotic Femoral Neck Fractures#827744
- Effect of Periprosthetic Fracture on Hip Function After Femoral Neck-preserving Total Hip Arthroplasty#874827
Record · ID 1096721
Retrieved via Conceptio: every document is proof-bundled with source, license, and retrieval metadata.
Retrieved via Conceptio: every document is proof-bundled with source, license, and retrieval metadata.
Bring this data into your agent: Connect via MCP or API · 20 free credits to start · no card required
Read the Docs → · View CLI source on GitHub · Conceptio Open Knowledge Archive
Read the Docs → · View CLI source on GitHub · Conceptio Open Knowledge Archive