Does Increasing the Compression Pause From 3 to 5 Seconds in Mechanical Compression Devices Increase Ventilation Success Rate and Return of Spontaneous Circulation?
To give chest compressions during cardiopulmonary resuscitation (CPR), mechanical chest compression devices can be used. During synchronous 30:2 CPR, the standard setting on these devices leave an automated 3-second chest compression pause after 30 compressions to facilitate caregivers in providing two ventilations. With this standard setting, research has shown that in less than half of ventilation pauses during CPR, those two ventilations are given. Increasing the ventilation pause duration to 5 seconds instead of 3 seconds is also an option following current guideline recommendations, and aligns with measured ventilation pause duration in manual CPR. Increasing pause duration to 5 seconds could result in an increased ventilation success rate. This multicenter randomized controlled trial will randomize LUCAS® mechanical compression devices to a standard setting of 3- or 5-second compression pauses. The main outcome will be the percentage of ventilation pauses in which two ventilations are successfully given. Secondary outcomes include the restoration of spontaneous circulation (ROSC), and the difference in (neurologically intact) survival. No study has been performed to evaluate this effect yet.
Conceptio Open Archive
Analyze & explore related research in Conceptio
Connect this record directly into your research workflow or AI agent. Explore citations across open repositories, query full text, and export structured proof bundles.
This document is indexed with metadata only: full text is not available in the archive for this record. Open the official source ↗
Related documents
- Continuous Compressions With Asynchronous Ventilations Using I-gel Device Versus 30:2 Approach During Simulated OHCA#868240
- Effects on Respiratory Patterns and Patient-ventilator Synchrony Using Pressure Support Ventilation#883282
- The Accuracy of Combined Parasternal Intercostal Muscle Thickening Fraction and Diaphragmatic Excursion in Predicting Failure of Libration From Mechanical Ventilation#855185
- A Study of Early Robotic Ablation by Substrate Elimination of Ventricular Tachycardia#867731
- The PneumoRator Study#896536
Record · ID 1101571
Retrieved via Conceptio: every document is proof-bundled with source, license, and retrieval metadata.
Retrieved via Conceptio: every document is proof-bundled with source, license, and retrieval metadata.
Bring this data into your agent: Connect via MCP or API · 20 free credits to start · no card required
Read the Docs → · View CLI source on GitHub · Conceptio Open Knowledge Archive
Read the Docs → · View CLI source on GitHub · Conceptio Open Knowledge Archive