Continuous Monitoring of Right Ventricular Function, Based on the Correlation Between the C-X Segment of the Central Venous Pressure Curve, and the Echocardiographic Evaluation of Right Ventricular Systolic Function
Close analysis of right ventricular function is still not done by all clinicians, even though it is indispensable; notably in cardiovascular ICUs. Right ventricular dysfunction is responsible for increased morbidity and marks a turning point in the patient's prognosis. It is difficult to analyse, and is principally assessed using echocardiography and by measuring the peak of the S' wave with pulsed Doppler and by measuring the tricuspid annular plane systolic excursion (TAPSE) in the TM mode. New studies have shown the interest of using 2D strain as a marker of systolic and diastolic function of the right ventricle. Finally, the use of 3D ultrasound seems to be more reliable than cardiac MRI for fine analysis of the right ventricle, even though it is rarely used in routine practice. Study of the right ventricle using ultrasonography alone requires experienced and available operators for closely repeated evaluations making it possible to detect right ventricle dysfunction quickly. US monitoring of left and right heart function is done systematically and repeatedly during post-operative care following heart surgery. This US evaluation could be optimized by finding a way to monitor the right ventricle continuously. From a physiological point of view, we know about the tight relationship between the aspect of the central venous pressure curve and more precisely the C-X segment (tricuspid bulging into the atrium and start of contraction of the right ventricle) and right ventricular function. We wish to analyse this segment, combined with a US evaluation, and to look for a possible correlation so as to allow continuous, easy-to-interpret monitoring of right ventricular systolic function. This will be facilitated by the systematic presence of a central venous catheter in every patient undergoing heart surgery, thus allowing central venous pressure to be monitored. To this end, we wish to collect different data from patients in the cardiovascular ICU, especially the
Conceptio Open Archive
Analyze & explore related research in Conceptio
Connect this record directly into your research workflow or AI agent. Explore citations across open repositories, query full text, and export structured proof bundles.
This document is indexed with metadata only: full text is not available in the archive for this record. Open the official source ↗
Related documents
- Comparison of Carotid Peak Systolic Velocity Variation With Aortic Peak Systolic Velocity Variation in Pediatric Non-Cardiac Surgery#897038
- Role of Echocardiography and Ultrasound Indices in Resuscitation of Septic Shock Patients#1058047
- Value of Cardiac Output Monitoring by Supra-sternal Doppler/Echocardiography in Intensive Care Unit#864535
- Ventripoint Single Ventricle Study#894121
- AI-based Echocardiographic Quantification in Heart Failure#1174019
Record · ID 1124921
Retrieved via Conceptio: every document is proof-bundled with source, license, and retrieval metadata.
Retrieved via Conceptio: every document is proof-bundled with source, license, and retrieval metadata.
Bring this data into your agent: Connect via MCP or API · 20 free credits to start · no card required
Read the Docs → · View CLI source on GitHub · Conceptio Open Knowledge Archive
Read the Docs → · View CLI source on GitHub · Conceptio Open Knowledge Archive