Conceptio › Archive › ClinicalTrials.gov
ClinicalTrials.gov public full text Public Domain

Insulation Failure in St. Jude Riata Leads

Hartford Hospital · 2013
ClinicalTrials.gov · Datasets · License: Public Domain · 2013
Open Source ↗
A recent study evaluated the Manufacturer and User Facility Device Experience (MAUDE) database, which contains reports of adverse events involving medical devices6,9. The FDA updates the database every two months. A total of 107 Riata leads with reported inside-out insulation breaks were found, of which 105 were available for analysis. The average age of the leads was 62.1+/-18.6 months. A total of 226 insulation defects were found with 143 inside-out insulation abrasions. Twenty-eight of the 105 leads (26.7%) had inside-out insulation defects underneath one or more of the high voltage-shocking coil. Of these, 23 were 8F and five were 7F Riata ST leads. Exposed cables or conductors were present in 32 leads and six leads had melted cables, presumably due to one or more high voltage shocks. 22 of the 43 leads assessed (51.2%) also had abraded ETFE cable coating exposing the conductor. Noise and other sensing issues were the most common signs of failure. Seven leads were found to have externalized cables and five exhibited electrical abnormalities. 31 patients (29.5%) experienced inappropriate shocks of which 41% had abraded cables. A critical decision facing physicians is how to screen and manage patients who are found to have externalized cables. Externalized cables on fluoroscopy may precede any electrical abnormalities. Also noise may not be detected on all ICD models. A recent case report suggested that changes in lead parameters might be transient and may be missed. The lead may function normally as the high-voltage and pace-sense cables are covered with ETFE, which serves as the second insulating barrier. As this is a very thin layer (0.0015 inches) the reliability of this to withstand a high-energy shock is unknown. This may lead to failure of appropriate therapy for life threatening arrhythmias. The aim of this study is to screen patients with ICD leads that potentially could have multiple different failure mechanisms, including inside-out insulation breaks,
Conceptio Open Archive

Analyze & explore related research in Conceptio

Connect this record directly into your research workflow or AI agent. Explore citations across open repositories, query full text, and export structured proof bundles.

This document is indexed with metadata only: full text is not available in the archive for this record. Open the official source ↗

Related documents

Record · ID 1150780
Retrieved via Conceptio: every document is proof-bundled with source, license, and retrieval metadata.
Bring this data into your agent: Connect via MCP or API · 20 free credits to start · no card required
Read the Docs → · View CLI source on GitHub · Conceptio Open Knowledge Archive