Conceptio › Archive › ClinicalTrials.gov
ClinicalTrials.gov public full text Public Domain

Levobupivacaine and Lidocaine for Paravertebral Block Causes Greater Hemodynamic Oscillations Than Levobupivacaine

University Hospital Dubrava · 2013
ClinicalTrials.gov · Datasets · License: Public Domain · 2013
Open Source ↗
hypotension
The purpose and the goal of this paper is to show whether the application of a combination of two local anesthetics, as opposed to the application of one local anesthetic at paravertebral block changes the hemodynamic variable. It is therefore a prospective randomized double- blind study, where we do a clinical trial in patients ASA(American Society of Anesthesiologists) 1 and 2 statuses between 18 and 80 years of age, using the ultrasound in plane technology.Upon arrival of patients in the unit for preparation procedures for anesthesia we set the ECG(electrocardiograph), noninvasive blood pressure, oxygen saturation, and arterial cannula in the radial artery After sterile washing of the dorsal surface, paravertebral space was identified with ultrasound using 8 Hz(hertz) linear transducer probe then needle position was confirmed with neurostimulation at the level of 2.0 - 5.0 mA(milliampere). When muscle contraction persisted at 0.4mA(milliampere), the anesthetic was applied in levels of Th 2, Th3, and Th 4 (7,0 milliliters per level). We applied the 0.5 % levobupivacaine and 2 % lidocaine, 7,0 milliliters of mixture per level in one group, while only 0.5 % levobupivacaine also 7,0 milliliters. by level in the second one. After that, the invasive hemodynamic monitoring was placed on patients and the induction with 1 % propofol 2-2.5 mg/kg.and Vecuronium 0,08 mg/kg. was performed with the application of supraglottic airway gel of appropriate size. The maintenance of anesthesia and sedation will be conducted with Propofol 1 % continuously ( 25-150 mcg / kg / min.)The measurements will be taken every 5 minutes during the first hour of the application of paravertebral block, then every 15 minutes during the second hour and if the operation takes more than two hours, the measurements are performed every 30 minutes. Postoperatively, invasive hemodynamic monitoring will be removed in post-anesthesia recovery room together with the arterial cannula and the patient will be s
Conceptio Open Archive

Analyze & explore related research in Conceptio

Connect this record directly into your research workflow or AI agent. Explore citations across open repositories, query full text, and export structured proof bundles.

This document is indexed with metadata only: full text is not available in the archive for this record. Open the official source ↗

Related documents

Record · ID 1172209
Retrieved via Conceptio: every document is proof-bundled with source, license, and retrieval metadata.
Bring this data into your agent: Connect via MCP or API · 20 free credits to start · no card required
Read the Docs → · View CLI source on GitHub · Conceptio Open Knowledge Archive