Positioning of EDI Catheter In Premature Infants
Nasogastric (NG) and orogastric (OG) feeding tubes have a high incidence of malpositioning, occurring in up to 59% of preterm infants (Lopes 2019). Ideally, the tip of the feeding tube (including the orifices) should be located within the body of the stomach. Malpositioning of the feeding tube can be classified as (i) being "too far out" where the tip of the catheter is located in the esophagus above the gastro-esophageal junction, potentially resulting in reflux, aspiration, apnea or (ii) being inserted "too far in" where the tip is located in the pylorus or the duodenum, leading to malabsorption of nutrients, diarrhea, and poor weight gain. Feeding tubes can also be found "curled up" inside the stomach (Quandt 2009) as much as 35% of the time. As well, one cannot ignore the risk of perforation, where the incidence has been reported to be 1.1% in extremely low birth weight (ELBW) infants (\<1000g) (n = 7/646) (Thanhaeuser M, 2019); of note: perforations occurred on the third day of life (range days 2-14) not during initial feeding tube placement. In 2008, a modified feeding tube was introduced to the market (Maquet Critical Care AB), which contains sensors placed in its wall, 13 mm above the feeding orifices, used for measuring the electrical activity of the diaphragm (Edi) during spontaneous breathing. The Edi signal is then used to neurally control mechanical ventilation, or for neural monitoring of the breathing pattern (Sinderby 1999; Beck 2016). The so-called "Edi catheter" comes with the manufacturer's recommended insertion measurements and verification window. In the Servo-I, the insertion distance is provided by a formula on the catheter packaging. In the Servo-U and Servo-n, the calculation for predicted insertion is provided by a tool in the ventilator. There is no available, published data upon which the manufacturer's recommendations were based. It is possible that obtaining appropriate positioning of the Edi catheter - based on a pattern of electrica
Conceptio Open Archive
Analyze & explore related research in Conceptio
Connect this record directly into your research workflow or AI agent. Explore citations across open repositories, query full text, and export structured proof bundles.
This document is indexed with metadata only: full text is not available in the archive for this record. Open the official source ↗
Related documents
- Comparison of Different Methods of Nasogastric Tube Insertion in Anesthetized and Intubated Patients#910501
- Comparison of Digital Intubation (Two-finger) and Video Laryngoscopy#1045135
- Esophageal and Gastric Registry and Biorepository#893685
- Nasogastric Tube After Laparoscopic Heller-Dor Myotomy#828547
- Percutaneous Endoscopic Gastrostomy (PEG) tube placement: indications, management, complications, outcomes, and care applied to endoscopy unit patients in a tertiary care hospital.#1121141
Record · ID 1172830
Retrieved via Conceptio: every document is proof-bundled with source, license, and retrieval metadata.
Retrieved via Conceptio: every document is proof-bundled with source, license, and retrieval metadata.
Bring this data into your agent: Connect via MCP or API · 20 free credits to start · no card required
Read the Docs → · View CLI source on GitHub · Conceptio Open Knowledge Archive
Read the Docs → · View CLI source on GitHub · Conceptio Open Knowledge Archive