ClinicalTrials.gov
public full text
Public Domain
Factors in Accuracy Studies Influencing Measured CGM Performance.
Primary objective is to assess the impact of different reference glucose measurement methods on the measured performance of a CGM system, aiming at further standardization for the assessment of CGM systems. Secondary objective is to describe the relationship between glucose concentration of venous, capillary and arterialized-venous measurement samples. Study design: Open-label trial. Study population: Nineteen patients with type 1 diabetes aged 18 years and older will be included. Intervention: The study will use the Dexcom G5 Mobile CGM. The participant will visit the clinical research center (CRC) twice during a 6 day period. These visits will have a duration of 8 hours. Blood will be drawn for the determination of glucose concentrations using venous, arterialized-venous and capillary sampling techniques. The patient will receive his usual breakfast and an increased insulin bolus will be administered to correct the breakfast glucose excursion with the aim of inducing a period of minor hypoglycemia. Blood sampling will continue until the end of the admission. The sensor will be worn until the end of the second 8-hour CRC session, which will be planned on day 6 or earlier depending on patient preference. The sensor will be removed and their sensor and blood glucose meter data downloaded from the devices. In the case of sensor failure before the first CRC session, patients will be instructed to insert a new sensor per the manufacturer's instruction and to notify study staff of the event. In case of failure of the sensor after the first CRC session but before the second CRC session, patients will return to the CRC for sensor removal and for data download.
Conceptio Open Archive
Analyze & explore related research in Conceptio
Connect this record directly into your research workflow or AI agent. Explore citations across open repositories, query full text, and export structured proof bundles.
This document is indexed with metadata only: full text is not available in the archive for this record. Open the official source ↗
Related documents
- Accuracy of Two CGM Systems Tested Simultaneously in Ambulatory Patients With Type 1 Diabetes#842654
- Modal Day Analysis of Self Monitoring Blood Glucose Versus Continuous Glucose Monitoring#1126988
- Measuring and Monitoring Blood Glucose Levels Utilizing Non-invasive Blood Glucose Monitoring Device#869116
- Continuous Glucose Monitoring (CGM) in Subjects With Type 2 Diabetes#806393
- Effect of CGM on Glucose Control in Non-insulin-treated Patients With Type 2 Diabetes Mellitus#906162
Record · ID 1173035
Retrieved via Conceptio: every document is proof-bundled with source, license, and retrieval metadata.
Retrieved via Conceptio: every document is proof-bundled with source, license, and retrieval metadata.
Bring this data into your agent: Connect via MCP or API · 20 free credits to start · no card required
Read the Docs → · View CLI source on GitHub · Conceptio Open Knowledge Archive
Read the Docs → · View CLI source on GitHub · Conceptio Open Knowledge Archive