Evaluation of a Novel Portable Capnograph (MARIE) in Adult Postoperative Patients
Postoperative respiratory complications are common and sometimes hard to detect early. Desaturation is a late sign of reduced minute ventilation, especially if the patient is on supplemental oxygen, and measurement of arterial or endtidal CO2 will rapidly detect a reduction in minute ventilation. Capnography offers a non-invasive and continuous measure of end-tidal expiratory pressure of carbon dioxide (EtCO2). Capnography is not a standard in postoperative care but rather quite rare. In the present study we evaluate a novel portable capnography device, MARIE, in postoperative patients. 1. The primary outcome is to describe the correlation of end-tidal CO₂ (EtCO₂) measurements between MARIETM (Oxlantics Medical) and Philips Intelli Vue X3 Microstream. 2. Secondary outcomes include 1. Correlation between PaCO₂ and EtCO₂ measured by MARIE and Philips Intelli Vue X3 Microstream, respectively. 2. Time trajectories of PaCO₂ and EtCO₂ measured using MARIE and Philips Intelli Vue X3 Microstream, respectively 3. The overall agreement between the EtCO2 measured by MARIE and Philips Intelli Vue X3 Microstream and PaCO2 4. Respiratory rate measured by MARIE compared to manual counting and Philips Intelli Vue X3. 5. Comparison of oxygen flow by MARIE and the rotameter. 6. Comfort as reported by patient. 7. Usability as reported by nurse. 8. Reasons for premature termination of MARIE 9. Registration of technical problems, for example unexpected shut downs and blockage by mucus. MARIE will be applied immediately after tracheal extubation after surgery. CO2 values from MARIE will be compared to EtCO2 and PaCO2 derived from capnography equipment routinely used in the hospital and blood gas analysis, at set intervals in the postoperative ward. Respiratory rate will be compared to our standard care monitors, ie Philips Intelli Vue X3, alongside manual counting. Rate of oxygen delivery, when applicable, will also be compared to the rotameter.
Conceptio Open Archive
Analyze & explore related research in Conceptio
Connect this record directly into your research workflow or AI agent. Explore citations across open repositories, query full text, and export structured proof bundles.
This document is indexed with metadata only: full text is not available in the archive for this record. Open the official source ↗
Related documents
- Trending Ability of End-Tidal Capnography to Reflect Arterial Carbon Dioxide Changes in One-Lung Ventilation#1292467
- A Comparison of the Detection of Hypoventilation During Deep Sedation Utilizing Nasal End Title CO@ Versus Transcutaneous CO2 Measurement Techniques#1321152
- Extracorporeal CO2 Removal in Hypercapnic Patients#1152880
- Validation of a System Using Aerosol Glycerine to Detect and Localize Intraoperatively Pulmonary Air Leaks#1197248
- Evaluation of a Non-invasive Cardiac Output Monitoring System.#865490
Record · ID 1322330
Retrieved via Conceptio: every document is proof-bundled with source, license, and retrieval metadata.
Retrieved via Conceptio: every document is proof-bundled with source, license, and retrieval metadata.
Bring this data into your agent: Connect via MCP or API · 20 free credits to start · no card required
Read the Docs → · View CLI source on GitHub · Conceptio Open Knowledge Archive
Read the Docs → · View CLI source on GitHub · Conceptio Open Knowledge Archive