Accuracy of Point-of-Care Measurement With the RapidPoint 500 Blood Gas Analyser
ICU patients are at high risk of ionic or metabolic disturbances during the course of their critical illness. Some of these disturbances might be life-threatening and require rapid response from physicians. Point-of-Care determination of electrolytes, glucose, hemoglobin and hematocrit ensures early detection (within 1 minute) of abnormal values and allows rapid and appropriate therapy. This technology has largely improved the quality of care in ICU. However, the accuracy of the measurement of those parameters had to be close enough to the reference method, usually perfomed in the central lab but time consuming. Recently, a novel generation of blood gas analyser has been released. Among them, the RapidPoint 500 is mounted with a 28-day cartridge which provides automatic calibrations and quality controls several times a day. Such a technology dramatically decreases the need for labs technical interventions. To date, there is no data reporting the accuracy of this device. Therefore, the investigators' aim is to compare the accuracy of the RapidPoint 500 with a reference measurement performed at the central laboratory (Beckman\&Coulter AU5800 for electrolytes and Beckman\&Coulter DXH for hemoglobin).
Conceptio Open Archive
Analyze & explore related research in Conceptio
Connect this record directly into your research workflow or AI agent. Explore citations across open repositories, query full text, and export structured proof bundles.
This document is indexed with metadata only: full text is not available in the archive for this record. Open the official source ↗
Related documents
- Comparative Study of GlySure Continuous Intra-vascular Glucose Monitoring and Intermittent Monitoring in Medical ICU#1101536
- Clinical Study of the Intravenous Blood Glucose System in Hospitalized Adult Elective or Non-Emergent Surgery and Medical/Surgical Intensive Care Unit Patients#847828
- Multicenter Evaluation of a New Strip-Based Blood Glucose System for Point-of-Care Testing in Critical and Non-Critical Care Settings#333048
- Evaluating System Accuracy of Blood Glucose Monitoring Systems for Self-testing in Managing Diabetes Mellitus#850607
- Comparison of Blood Glucose Measurement Values#1280218
Record · ID 1397088
Retrieved via Conceptio: every document is proof-bundled with source, license, and retrieval metadata.
Retrieved via Conceptio: every document is proof-bundled with source, license, and retrieval metadata.
Bring this data into your agent: Connect via MCP or API · 20 free credits to start · no card required
Read the Docs → · View CLI source on GitHub · Conceptio Open Knowledge Archive
Read the Docs → · View CLI source on GitHub · Conceptio Open Knowledge Archive