ClinicalTrials.gov
public full text
Public Domain
Clinical Evaluation of an Alarm Activated Detection System to Enable Early Intervention of Emerging Respiratory Decline With the Linshom Medical Continuous Predictive Respiratory Sensor (CPRS)
Investigators will enroll 493 patients who will undergo non-cardiac surgery, receive supplemental oxygen via face mask or nasal cannula, and will be on continuous pulse oximetry monitor in the Post Anesthesia Care Unit (PACU). Research personnel will screen and select subjects for this study. The CRA will ensure that each subject meets the enrollment criteria, and the informed consent is properly executed. Upon arrival at the PACU, each subject will be fitted with a supplemental oxygen mask or nasal cannula containing the Linshom sensor, which will be connected to Linshom Cyber G-15 monitor for data collection. A pulse oximeter will be applied to the hand (non-NIBP arm), which will be connected to a hospital monitor (SOC). The Linshom G-15 monitor will collect data every 100 milliseconds. The Linshom CPRM will automatically initiate baseline data capture. The CRA will begin recording any clinical interventions (e.g., medications and stimulation upon detection of changes in patient's condition) that are performed by the PACU staff, paying close attention to time at which those interventions occurred. Data collection will be performed throughout the subject's entire PACU stay. After data collection, the Linshom engineers will retrieve the data from all monitors and time-sync all data collected from each patient (Linshom CPRM and pulse oximetry). Manually recorded data regarding the time points at which clinical interventions were provided by the PACU staff will also be reviewed and those time points will be noted as RDEs. The Linshom CPRM system monitors the distinct metric of RDE occurrence. Throughout a given patient's stay, nurses will be provided with two distinct cues (each cue comprised of an auditory and visual component), 1 from CPRM, 1 from SoC, alerting them to a patient's respiratory state. In addition, clinical staff will have access to a summary metrics of critical parameters and RDE occurrences on the Linshom monitor (total RDE count, time since last RD
Conceptio Open Archive
Analyze & explore related research in Conceptio
Connect this record directly into your research workflow or AI agent. Explore citations across open repositories, query full text, and export structured proof bundles.
This document is indexed with metadata only: full text is not available in the archive for this record. Open the official source ↗
Related documents
- Added value of routine pulse oximetry use within Integrated Management of Childhood Illness guidelines in primary care in West Africa: insight from AIRE#284357
- Non Contact Measurement of Vital Signs#858982
- The Role of the Device Operating Under the Continuous Positive Airway Pressure in the Recovery Process of Cochlea#908797
- The Association of CPAP Compliance Study#843445
- Study of Monitoring Exhaled NO in Symptomatic Asthmatic Adults and Children During Anti-inflammatory Treatment#1245058
Record · ID 1430113
Retrieved via Conceptio: every document is proof-bundled with source, license, and retrieval metadata.
Retrieved via Conceptio: every document is proof-bundled with source, license, and retrieval metadata.
Bring this data into your agent: Connect via MCP or API · 20 free credits to start · no card required
Read the Docs → · View CLI source on GitHub · Conceptio Open Knowledge Archive
Read the Docs → · View CLI source on GitHub · Conceptio Open Knowledge Archive