Conceptio › Archive › ClinicalTrials.gov
ClinicalTrials.gov public full text Public Domain

EnSeal Efficacy and Bursting Pressure in Human Vessels

University of Illinois at Chicago · 2011
ClinicalTrials.gov · Datasets · License: Public Domain · 2011
Open Source ↗
na
In this study the investigators will include adult patients who are not part of a vulnerable patient population. Inclusion criteria include patients who will be undergoing resection of part of their colon that will require dividing the IMA. The investigators will use the resected surgical specimens for our project. The investigators will use the EnSeal on all major vessels in our procedure. The investigators will use the EnSeal 5 mm round head model. Due to the nature of the project, we will apply for IRB approval prior to beginning our research. The investigators plan to include 60 total patients in the study, 30 at the University of Illinois and 30 at Lutheran General Hospital. Prior to resection, the investigators will use a sterile caliper to take an in-vivo measurement of the IMA and IMV. Immediately after resection, the investigators will remove the sealed proximal end of the IMA and the 3 cm distal to it from the surgical specimen. The investigators will similarly prepare the IMV. The investigators will inspect our vessels for any iatrogenic traumatic tears. If the vessels are suitable, the investigators will then gentle apply manual traction to remove any blood or clots within the lumen. The investigators will measure the outer diameter of the vessels using a digital caliper. If there are small branches, the investigators will tie them off with suture. The unsealed end will then be attached to the burst pressure tester with suture and it will be tested for the bursting pressure. The device measures pressure continuously as it infuses the segment with normal saline at a steady rate (50 ml/hr). A leak will be determined by a decrease in intra-luminal pressure of 100 mm Hg or a visible leak. A failure to seal the vessels will be determined by a bursting pressure of less than 100 mm Hg. It should be noted that each section would only be pressure-tested once. All of our data will be collected on the enclosed data sheet we have created for use in this protocol. T
Conceptio Open Archive

Analyze & explore related research in Conceptio

Connect this record directly into your research workflow or AI agent. Explore citations across open repositories, query full text, and export structured proof bundles.

This document is indexed with metadata only: full text is not available in the archive for this record. Open the official source ↗

Related documents

Record · ID 1444185
Retrieved via Conceptio: every document is proof-bundled with source, license, and retrieval metadata.
Bring this data into your agent: Connect via MCP or API · 20 free credits to start · no card required
Read the Docs → · View CLI source on GitHub · Conceptio Open Knowledge Archive