Conceptio › Archive › EUR-Lex
EUR-Lex public full text Public Domain

Commission Decision (EU) 2026/2404 of 29 October 2026 amending Decision (EU) 2021/2147 as regards the approval of civil aviation security equipment with EU Stamp marking

European Union · 2026 · Publications Office of the European Union
EUR-Lex · Legal · License: Public Domain · 2026
Open Source ↗
decisioneu-law
Conceptio Open Archive

Analyze & explore related research in Conceptio

Connect this record directly into your research workflow or AI agent. Explore citations across open repositories, query full text, and export structured proof bundles.

L_202602404EN.000101.fmx.xml Official Journal of the European Union EN L series 2026/2404 3.11.2026 COMMISSION DECISION (EU) 2026/2404 of 29 October 2026 amending Decision (EU) 2021/2147 as regards the approval of civil aviation security equipment with ‘EU Stamp’ marking (Text with EEA relevance) THE EUROPEAN COMMISSION, Having regard to the Treaty on the Functioning of the European Union, Having regard to Regulation (EC) No 300/2008 of the European Parliament and the Council of 11 March 2008 on common rules in the field of civil aviation security and repealing Regulation (EC) No 2320/2002 ( 1 ) , and in particular Article 4(3) thereof, Whereas: (1) The detailed measures for the implementation of the common basic standards referred to in Article 4(3) of Regulation (EC) No 300/2008 include procedures for approval and use of civil aviation security equipment. (2) Commission Implementing Regulation (EU) 2015/1998 ( 2 ) establishes a harmonised regime of approval for the installation of civil aviation security equipment. (3) Steps taken to ensure that civil aviation security equipment meets the required performance standards have been harmonised to ensure the best implementation of the common basic standards in aviation security. (4) The Commission acknowledges the common evaluation process of the European Civil Aviation Conference as a mandatory pre-condition for the approval of civil aviation security equipment. The Commission grants a temporary ‘EU Stamp pending’ marking status to equipment confirmed by the common evaluation process only after it has received the Level 2 reports. (5) Security equipment approved at national level by derogation from the harmonised regime of approval should not automatically receive the ‘EU Stamp’ marking. The Commission may grant a temporary ‘EU Stamp pending’ marking status to equipment approved at national level only after it has received the test reports. (6) The Commission should adopt a decision to grant an ‘EU Stamp’ marking to equipment that has received a temporary ‘EU Stamp pending’ marking status. (7) Commission Decision (EU) 2021/2147 ( 3 ) establishes a consolidated list of approved civil aviation security equipment with ‘EU Stamp’ marking status to equipment confirmed by the common evaluation process of the European Civil Aviation Conference, for the purpose of installation and use throughout the Union. (8) Since its adoption, several new configurations of civil aviation security equipment have successfully undergone the common evaluation process of the European Civil Aviation Conference, and the relevant Level 2 reports have been submitted to the Commission that has granted the ‘EU Stamp pending’ marking status thereto. (9) The Annex to Decision (EU) 2021/2147 should therefore be amended by adding the new configurations of civil aviation security equipment to which an ‘EU Stamp pending’ marking status was granted. As the number of configurations to be added are deemed to significantly modify the existing Annex, it is more appropriate to replace that Annex. (10) The Commission should maintain a consolidated Union database listing equipment allowed for installation and use throughout the Union, HAS ADOPTED THIS DECISION: Article 1 In Decision (EU) 2021/2147, the Annex is replaced by the text in the Annex to this Decision. The ‘Union database on supply chain security – security equipment’ shall be updated accordingly. Article 2 This Decision shall enter into force on the twentieth day following that of its publication in the Official Journal of the European Union . Done at Brussels, 29 October 2026. For the Commission The President Ursula VON DER LEYEN ( 1 ) OJ L 97, 9.4.2008, p. 72 , ELI: http://data.europa.eu/eli/reg/2008/300/oj . ( 2 ) Commission Implementing Regulation (EU) 2015/1998 of 5 November 2015 laying down detailed measures for the implementation of the common basic standards on aviation security ( OJ L 299, 14.11.2015, p. 1 , ELI: http://data.europa.eu/eli/reg_impl/2015/1998/oj ). ( 3 ) Commission Decision (EU) 2021/2147 of 3 December 2021 on the approval of civil aviation security equipment with ‘EU stamp’ marking ( OJ L 433, 6.12.2021, p. 25 , ELI: http://data.europa.eu/eli/dec/2021/2147/oj ). ANNEX ANNEX List of approved civil aviation security equipment with “EU Stamp” marking 1. WALK-THROUGH METAL DETECTION (WTMD) EQUIPMENT WTMD equipment that has passed the location indication test can be used in combination with Shoe Metal Detection equipment and are indicated with (SMD). For the evaluation of WTMD equipment (Standard 1 and Standard 2), there is no requirement for a maximum Non-Threat Alarm Rate. Unique identifier Manufacturer Designation Detailed configuration Standard Status Hardware Detection algorithm System software Auxiliary hardware Concept of operations WTMD000001 CEIA 02PN10K-EVO 02PN10K/PZ-EVO V2.00x Control Unit Board SCD73 Antenna: SS65 PV 1010, IS = EU-STD-2 n/a n/a FI060K0098v1103xUK (Quick guide) 2.1 (SMD) EU Stamp WTMD000002 CEIA HI-PE PLUS HIPEPLUS/PZ Antenna: SS65 LXDA2000 n/a n/a FI060K0108v2300 2.1 (SMD) EU Stamp WTMD000003 Rapiscan Metor 6E Electronics, p/n 23106448 Antenna: Coil Set1, p/n 23109437, Coil Set2, p/n 23109438 Software, Detection Core, Metor 6E p/n 101021459, v1.00, EU2 n/a n/a CONOPS, ECAC CEP, Metor 6E, “Quick Guide”, p/n D01499, v1 2 EU Stamp WTMD000004 Nuctech MD2000 1.0 Antenna: MBP1-2.13 MBP2-2.13 08.00.06.00 n/a n/a V1.0 / 01-2020 2 EU Stamp WTMD000005 CEIA PMD3 Plus PMD3Plus/PZ Antenna: SS65 LXDA2000 (EU-STD-2) n/a n/a FI060K0108v2310 2.1 (SMD) EU Stamp WTMD000006 CEIA 02PN20 02PN20/PZ Antenna: SS65 LXDA2000 (EU-STD-2) n/a n/a FI060K0108v2320 2.1 (SMD) EU Stamp WTMD000007 Garrett PD 6500i 2340510 and 2340720; Antenna: 223320x and 223335x ECAC / SE = 162 n/a n/a 1532010 2.1 EU Stamp WTMD000008 Rapiscan Metor 900M Electronics, p/n 23113530; Antenna: RX Coils, p/n 101017805, TX Coils, p/n 101017806 V 1.3.1, EU2 HD, Sensitivity 100 n/a n/a V1.0, p/n D05693 2 (SMD) EU Stamp WTMD000009 CEIA 02PN20 Elliptic 02PN20/EZ Antenna: NN76 LXDA2000 (EU-STD-2) n/a n/a FI060K0108v2400 2.1 (SMD) EU Stamp WTMD000010 CEIA PMD2 PLUS Elliptic PMD2PLUS/EZ Antenna: NN76 LXDA2000 (EU-STD-2) n/a n/a FI060K0108v2400 2.1 (SMD) EU Stamp WTMD000011 Garrett Paragon Paragon; Antenna: Panel A 223750x and Panel B 223760x ECAC (DSP Ver K) n/a n/a 1557900 2.1 (SMD) EU Stamp 2. HAND-HELD METAL DETECTION (HHMD) EQUIPMENT Left intentionally blank 3. X-RAY EQUIPMENT Left intentionally blank 4. EXPLOSIVE DETECTION SYSTEM (EDS) EQUIPMENT 4.1 EDS for hold baggage Any full tests started prior to 1 January 2016 did not test the configuration for shielding capacity. The term “tray” can include totes, tubs, bins etc. Any configurations meeting the standard 3.1 for EDS are automatically considered as having achieved EDS Standard 3. Unique identifier Manufacturer Designation Detailed configuration Standard Status Hardware Detection algorithm System software Auxiliary hardware Concept of operations EDSHB00002 Smiths Detection XRD 3500 Varian MCS-7074A X-Ray Tube CANBERRA Germanium Detector Library “ECAC” – Nr 8.2.2.2 n/a On belt n/a 3 EU Stamp EDSHB00003 Reveal Imaging Technologies CT80DR CT80DR 4.2.14 5.3.0.123 On belt n/a 3 EU Stamp EDSHB00005 Smiths Detection CTX 9400 DSi CTX 9400 Inspection: GInsp_2.3.0 ECACa Reconstruction: Recon_2.0.2 n/a On belt n/a 3 EU Stamp EDSHB00006 Leidos eXaminer XLB 10-70500-01 06.17 00.45 On belt n/a 3 EU Stamp EDSHB00007 Smiths Detection CTX 5800 CTX 5800 Inspection: 5800 ECAC SB CB 2.17.7 Reconstruction: 3.1.2 n/a On belt n/a 3 EU Stamp EDSHB00008 Leidos eXaminer SX 10-64987-01 5.11 01.01 On belt n/a 3 EU Stamp EDSHB00010 Leidos eXaminer 3DX-ES 1000-11700-00 112.3 8.2 On belt n/a 3 EU Stamp EDSHB00014 Smiths Detection CTX 9800 DSi CTX 9800 High-Speed Configuration Inspection: 9800 ECAC HS CB 2.18.1 Reconstruction: 3.3.0 n/a On belt n/a 3 EU Stamp EDSHB00015 Smiths Detection CTX 5500 DS CTX 5500 Inspection: p 17_0_0 Reconstruction: trecon 3.0.0 n/a On belt n/a 3 EU Stamp EDSHB00016 Leidos eXaminer 3DX Part no: 200001 112.3 8.2 On belt n/a 3 EU Stamp EDSHB00017 Nuctech XT2080 XT2080 DPC 1.1 EDS 1.1 n/a On belt n/a 3 EU Stamp EDSHB00018 Smiths Detection HI-SCAN 10080 XCT HS 10080 XCT 07-05-00 n/a On belt n/a 3 EU Stamp EDSHB00019 Leidos eXaminer 3DX Part no: 200001 112.3 7.1 On belt n/a 3 EU Stamp EDSHB00020 Leidos eXaminer XLB 10-70500-01 06.17 04 On belt n/a 3 EU Stamp EDSHB00021 Smiths Detection CTX 5800 CTX 5800 with Checkerboard Inspection: 5800 ECAC SB CB 2.18.6 Reconstruction: 5800 CB 4.0.1 n/a On belt n/a 3 EU Stamp EDSHB00022 Smiths Detection CTX 9800 DSi CTX 9800 High-Speed with Checkerboard Inspection: 9800 ECAC HS CB 2.18.6 Reconstruction: 9800 CB 4.0.1 n/a On belt n/a 3 EU Stamp EDSHB00023 Rapiscan RTT110 RTT110 1.0.22 8.13 On belt n/a 3 EU Stamp EDSHB00024 Smiths Detection HI-SCAN 10080 XCT HS 10080 XCT 07-20-09 n/a On belt n/a 3 EU Stamp EDSHB00025 Leidos eXaminer 3DX eXaminer 3DX 112.5 10.1 On belt n/a 3 EU Stamp EDSHB00026 Leidos eXaminer 3DX-ES 200001 112.5 10.1 On belt n/a 3 EU Stamp EDSHB00027 Leidos eXaminer SX 10-64987-01 5.14 06 On belt n/a 3 EU Stamp EDSHB00028 Leidos MV3D 1000-10001-D1 7.6.2 L200 1.0 On belt n/a 3 EU Stamp EDSHB00029 Leidos MV3D 1000-10001-D1 7.6.2 S200 1.0 On belt n/a 3 EU Stamp EDSHB00030 Smiths Detection CTX 5800 CTX 5800 with Checkerboard Inspection: 5800 ECAC SB CB 2.18.13 Reconstruction: 5800 CB 4.0.1 SC n/a On belt n/a 3 EU Stamp EDSHB00031 Smiths Detection CTX 5800 CTX 5800 with Checkerboard Inspection: 5800 ECDMD SB CB 2.18.13 Reconstruction: 5800 CB 4.0.1 SC n/a On belt n/a 3 EU Stamp EDSHB00033 Rapiscan RTT110 RTT110 1.0.24 8.13 On belt n/a 3 EU Stamp EDSHB00034 Reveal Imaging Technologies CT-120 CT-120 5.20.3.3 n/a On belt P/N 81080 Revision3 Draft 3 EU Stamp EDSHB00035 Reveal Imaging Technologies CT-120 CT-120 5.20.3.5 n/a On belt P/N 81080 Revision3 Draft 3 EU Stamp EDSHB00036 Smiths Detection CTX 9800 DSi CTX 9800 High-Speed with Checkerboard Inspection: 9800 ECAC HS CB 2.18.17 Reconstruction: 9800 CB HS 4.0.1 SC n/a On belt n/a 3 EU Stamp EDSHB00037 Smiths Detection CTX 9800 DSi CTX 9800 High-Speed with Checkerboard Modified 605577-1, per DW 1365.2 Inspection: 9800 ECDMD HS CB 2.18.18 Reconstruction: 9800 CB HS 4.0.1 SC n/a On belt n/a 3 EU Stamp EDSHB00039 Leidos MV3D 1000-10001-D1 8.0.3 S200 n/a On belt n/a 3 EU Stamp EDSHB00040 Smiths Detection HI-SCAN 10080 XCT HS 10080 XCT 08-27-16 n/a Tray: Crisplant Material n°: CrisBag® V5 SBT 507B595.XXX, Art. n°: 7308972 n/a 3 EU Stamp EDSHB00041 Smiths Detection HI-SCAN 10080 XCT HS 10080 XCT 08-27-16 n/a Tray: Crisplant Material n°: CrisBag® V5 LBT 507B596.XXX, Art. n°: 7308974 n/a 3 EU Stamp EDSHB00042 Smiths Detection HI-SCAN 10080 XCT HS 10080 XCT 08-27-16 n/a Tray: FRAPORT Material n°: M020745 n/a 3 EU Stamp EDSHB00043 Smiths Detection HI-SCAN 10080 XCT HS 10080 XCT 08-27-16 n/a Tray: Vanderlande Material n°: 011505-393-00001 n/a 3 EU Stamp EDSHB00044 Smiths Detection HI-SCAN 10080 XCT HS 10080 XCT 08-27-16 n/a Tray: Vanderlande Material n°: 011505-890-00001 n/a 3 EU Stamp EDSHB00045 Leidos eXaminer XLB 10-70500-01 06.27 04 Tray: Crisplant – CrisBag® V5 SBT, Art. N°: 7308972 n/a 3 EU Stamp EDSHB00046 Nuctech XT2080AD XT2080AD DHV 1.0 OIS V2.0.004 Algorithm V3.1.18 OIS V2.0.008 Algorithm V3.1.18 n/a On belt V1.2 3 EU Stamp EDSHB00047 Smiths Detection CTX 9800 DSi MD Checkerboard HS Configuration Inspection: 9800 ECDMD HS CB 3.0.5 Recon Prep: LibPrep 9800 HS CB DMA 6.0.0 Reconstruction: LibRecon 9800 HS CB DMA 6.0.2 n/a Tray: Beumer / Crisplant 7308972 n/a 3 EU Stamp EDSHB00048 Smiths Detection CTX 9800 DSi MD Checkerboard HS Configuration Inspection: 9800 ECDMD HS CB 3.0.5 Recon Prep: LibPrep 9800 HS CB DMA 6.0.0 Reconstruction: LibRecon 9800 HS CB DMA 6.0.2 n/a Tray: Vanderlande long 011531-727-00001 n/a 3 EU Stamp EDSHB00049 Smiths Detection CTX 9800 DSi MD Checkerboard HS Configuration Inspection: 9800 ECDMD HS CB 3.0.5 Recon Prep: LibPrep 9800 HS CB DMA 6.0.0 Reconstruction: LibRecon 9800 HS CB DMA 6.0.2 n/a On belt n/a 3 EU Stamp EDSHB00050 Leidos MV3D 1000-10001-D1 8.4.6 L200 n/a Tray: Vanderlande SBT, Item No 011505-890-00001 n/a 3 EU Stamp EDSHB00051 Nuctech XT2100 XT2100 DHV 1.0 OIS V2.0.004 Algorithm V3.1.22 OIS V2.0.008 Algorithm V3.1.22 OIS V2.0.004 Algorithm V3.1.23 OIS V2.0.008 Algorithm V3.1.23 n/a On belt CONOPS: V1.2 3 EU Stamp EDSHB00052 Smiths Detection CTX 9800 DSi MD Checkerboard HS Configuration Inspection: 9800 ECDMD HS CB 3.0.5 Reconstruction: LibRecon 9800 HS CB DMA 8.0.0 Recon Post: Postproc SC 8.0.0 n/a On belt n/a 3 EU Stamp EDSHB00053 Smiths Detection CTX 9800 DSi MD Checkerboard HS Configuration Inspection: 9800 ECAC HS CB 3.0.5 Reconstruction: LibRecon 9800 HS CB DMA 8.0.0 Recon Post: Postproc SC 8.0.0 n/a On belt n/a 3 EU Stamp EDSHB00054 Smiths Detection CTX 9800 DSi MD Checkerboard HS Configuration Inspection: 9800 ECDMD HS CB 3.0.5 Reconstruction: LibRecon 9800 HS CB DMA 8.0.0 Recon Post: Postproc SC TUB 8.0.0 n/a Tray: Beumer / Crisplant 400B767 n/a 3 EU Stamp EDSHB00055 Smiths Detection HI-SCAN 10080 XCT HS 10080 XCT 08-28-19 n/a Trays: Crisplant CrisBag NG Tray V3 part n°: 400B767 and 419B629 n/a 3 EU Stamp EDSHB00056 SureScan x1000 x1000 – HiSpeed (Stationary Gantry) 4.0.0 n/a On belt x1000B-i1310-A01 – x1000 Scanner Operations Manual, x1000B-i1310-B00 – x1000 Scanner Operations Manual 3 EU Stamp EDSHB00057 Reveal Imaging Technologies CT-120 CT-120 5.20.3.11 n/a On belt P/N 81080 Revision3 Draft 3 EU Stamp EDSHB00058 Reveal Imaging Technologies CT-120 CT-120 5.20.3.12 n/a On belt P/N 81080 Revision3 Draft 3 EU Stamp EDSHB00059 Reveal Imaging Technologies CT-120 CT-120 5.20.3.13 n/a On belt P/N 81080 Revision3 Draft 3 EU Stamp EDSHB00060 Smiths Detection CTX 9800 DSi MD Checkerboard HS Configuration Inspection: 9800 ECAC HS CB 3.0.5 Reconstruction: LibRecon 9800 HS CB DMA 8.0.2 Recon Post: Postproc SC 8.0.0 n/a On belt n/a 3 EU Stamp EDSHB00061 Smiths Detection CTX 9800 DSi MD Checkerboard HS Configuration Inspection: 9800 ECDMD HS CB 3.0.5 Reconstruction: LibRecon 9800 HS CB DMA 8.0.2 Recon Post: Postproc SC 8.0.0 n/a On belt n/a 3 EU Stamp EDSHB00062 Leidos MV3D 1000-10001-D1 8.5.2 L200 n/a Tray: Crisplant CrisBag V5 SBT, Art. No 7308972 n/a 3 EU Stamp EDSHB00064 Smiths Detection CTX 5800 CTX 5800 Inspection: 5800 ECAC SB EDM 3.0.16 Reconstruction: 9.1.1 Recon Post: 9.1.1 n/a On belt n/a 3 EU Stamp EDSHB00065 Leidos MV3D 1000-10001-D1 8.5.4 L200 n/a Tray: Fraport AG, Art. N°M020745 n/a 3 EU Stamp EDSHB00066 Nuctech XT2100HS XT2100HS DHV 1.0 XT2100HS DHV 1.1 OIS V2.0.008 Algorithm V3.1.26 n/a On belt XT2100HS CONOPS v4.0 3 EU Stamp EDSHB00067 Smiths Detection CTX 9800 Dsi (0.5 m/s configuration) 1003589-02 Inspection: 9800 ECAC UHS EDM 3.0.18 Reconstruction: 9.2.0 Recon Post: 9.2.0 n/a On belt n/a 3 EU Stamp EDSHB00068 SureScan x1000 (0.5 m/s configuration) x1000 – HiSpeed.5 (Stationary Gantry) 4.6.0 n/a On belt x1000B-i1310-A01 – x1000 Scanner Operations Manual, x1000B-i1310-B00 – x1000 Scanner Operations Manual 3.1 EU Stamp EDSHB00069 Leidos MV3D 1000-10001-D1 8.9.6 L200 n/a Tray: Crisplant CrisBag V5 LBT, Art. No 7308974 n/a 3 EU Stamp EDSHB00070 Leidos MV3D 1000-10001-D2 8.9.4 N200 n/a On belt n/a 3 EU Stamp EDSHB00071 Smiths Detection HI-SCAN 10080 XCT HS 10080 XCT 09-21-09 n/a Tray: BigBear BBF11012 n/a 3 EU Stamp EDSHB00072 Nuctech XT2100HS XT2100HS DHV 1.0 XT2100HS DHV 1.1 Algorithm V3.1.27 n/a Tray: Beumer CrisBag V5 SBT Art No 7308972; Vanderlande tote No 011505-393-00001 XT2100HS CONOPS v4.0 3 EU Stamp EDSHB00073 Nuctech XT2100HS XT2100HS DHV 1.0 Algorithm V3.1.32 n/a Tray: AENA.MAD-01 XT2100HS_CONOPS_v3.5_20181115 3 EU Stamp EDSHB00074 Nuctech XT2100HS XT2100HS DHV 1.0 XT2100HS DHV 1.1 V3.1.28.2 n/a On belt XT2100HS CONOPS v4.0 3.1 EU Stamp EDSHB00075 Nuctech XT2100-R XT2100-R DHV 1.0 Algorithm V3.1.27 n/a Tray: Beumer CrisBag® tote No 843139000, Vanderlande tote No 011505-393-00001 V1.0 3 EU Stamp EDSHB00076 Leidos MV3D 1000-10001-D1 9.0.4 S100 n/a On belt n/a 3 EU Stamp EDSHB00077 Leidos MV3D 1000-10001-D1 9.0.4 S200 n/a Tray: Crisplant CrisBag® V3 SBT, Art. No 400B767 n/a 3 EU Stamp EDSHB00078 Leidos MV3D 1000-10001-D1 9.0.5 S100 n/a On belt n/a 3 EU Stamp EDSHB00079 Leidos MV3D 1000-10001-D1 9.1.2 L200 n/a Tray: Vanderlande, Item No. 001036-241-00002; Tray Vanderlande Ref: 001036-103-00001 Rev B01; Tray Vanderlande Ref: 001036-103-00001 Rev C01 n/a 3 EU Stamp EDSHB00080 Smiths Detection HI-SCAN 10080 XCT HS 10080 XCT 09-21-09 n/a On belt n/a 3 EU Stamp EDSHB00081 Smiths Detection HI-SCAN 10080 XCT HS 10080 XCT 09-47-17 n/a On belt n/a 3.1 EU Stamp EDSHB00082 Smiths Detection CTX 9800 Dsi (0.5 m/s configuration) 1003589-03 Inspection: 9800 ECAC UHS EDM 3.1.17 Reconstruction: 9.2.0 Recon Post: 9.2.0 n/a On belt n/a 3 EU Stamp EDSHB00083 Smiths Detection CTX 9800 Dsi (0.5 m/s configuration) 1003589-03 Inspection: 9800 ECAC UHS EDM 3.2.0 Reconstruction: 9.2.0 Recon Post: 9.2.0 n/a On belt n/a 3 EU Stamp EDSHB00084 Smiths Detection CTX 9800 Dsi (0.5 m/s configuration) 1003589-03 Inspection: 9800 ECAC UHS EDM 3.2.1 Reconstruction: 9.2.0 Recon Post: 9.2.0 n/a On belt n/a 3 EU Stamp EDSHB00085 Smiths Detection CTX 9800 Dsi (0.3 m/s configuration) CTX 9800 DSi (0.3 m/s configuration) Inspection: ECAC HS EDM 3.1.4 Reconstruction: 9.2.0 Recon Post: 9.3.3 n/a On belt n/a 3 EU Stamp EDSHB00086 SureScan x1000 (0.5 m/s configuration) x1000 – HiSpeed.5 (Stationary Gantry); (200000009900B ASSY, TOP LEVEL) 4.6.1 n/a On belt x1000B-i1310-C00 – x1000 Scanner Operations Manual 3.1 EU Stamp EDSHB00087 Smiths Detection CTX 9800 Dsi (0.5 m/s configuration) CTX 9800 Dsi (0.5 m/s configuration) Inspection: 9800 ECAC UHS EDM 3.1.17 Reconstruction: 9.2.0 Recon Post: 9.3.6 n/a Tray Vanderlande Ref: 001036-241-00002; Tray Vanderlande Ref: 001036-103-00001 Rev B01; Tray Vanderlande Ref: 001036-103-00001 Rev C01 n/a 3 EU Stamp EDSHB00088 Smiths Detection HI-SCAN 10080 XCT HS 10080 XCT 09-21-09 n/a Tray Vanderlande Ref: 001036-241-00002; Tray Vanderlande Ref: 001036-103-00001 Rev B01; Tray Vanderlande Ref: 001036-103-00001 Rev C01 n/a 3 EU Stamp EDSHB00089 Smiths Detection CTX 9800 DSi MD Checkerboard HS Configuration Inspection: 9800 ECDMD HS CB 3.0.5 Reconstruction: LibRecon 9800 HS CB DMA 8.0.2 Recon Post: Postproc SC TUB 8.0.0 n/a Tray: Beumer / Crisplant 400B767 n/a 3 EU Stamp EDSHB00090 Leidos MV3D 1000-10001-D1 9.7.5 L100 n/a On belt n/a 3.1 EU Stamp EDSHB00091 Smiths Detection CTX 9800 Dsi (0.5 m/s configuration) CTX 9800 DSi Comet x-ray tube (0.5 m/s configuration) Inspection: 9800 ECDMD UHS EDM 3.6.0 Reconstruction: 9.2.0 Recon Post: 9.2.0 n/a On belt n/a 3.1 EU Stamp EDSHB00092 Rapiscan RTT110 RTT110 1.0.47 8.14 Bigbear Tray (ref: BBF11012) n/a 3 EU Stamp EDSHB00093 Nuctech XT2100HS XT2100HS DHV 1.0 XT2100HS DHV 1.1 Algorithm V3.1.30 n/a On belt CONOPS XT2100HS v4.0 3.1 EU Stamp EDSHB00094 Nuctech XT2100HS XT2100HS DHV 1.0 XT2100HS DHV 1.1 Algorithm V3.1.31 n/a On belt CONOPS XT2100HS v4.0 3.1 EU Stamp EDSHB00095 Nuctech XT2100HS DHV 1.1 Algorithm v3.1.36 n/a Daifuku (P/N BTSP0007001C) CONOPS XT2100HS v4.0 3.1 EU Stamp EDSHB00096 Rapiscan RTT110 RTT110 1.4.04 8.14 On belt n/a 3.1 EU Stamp EDSHB00097 Nuctech XT2100HS DHV 1.1 Algorithm V3.1.39 n/a Vanderlande (P/N 011505-706-00001) CONOPS XT2100HS V4.0 3.1 EU Stamp EDSHB00099 Smiths Detection HI-SCAN 10080 XCT HS 10080 XCT 09-63-09 n/a Tray: AENA.MAD-001 On belt n/a 3.1 EU Stamp EDSHB00100 Smiths Detection CTX 9800 DSi (0.5 m/s configuration) CTX 9800 DSi Comet x-ray tube (0.5 m/s configuration) Inspection: 9800 ECDMD UHS EDM 3.6.2 Reconstruction: 9.2.0 Recon Post: 9.2.0 n/a On belt n/a 3.1 EU Stamp EDSHB00101 Nuctech XT2100HS XT2100HS DHV 1.0 XT2100HS DHV 1.1 Algorithm v3.1.37 n/a Beumer CrisBag V5 SBT Art No 7308972; Vanderlande Tote 850 (P/N 011505-393-00001); Tray Vanderlande Ref: 001036-241-00002; Tray Vanderlande Ref: 001036-103-00001 Rev B01; Tray Vanderlande Ref: 001036-103-00001 Rev C01 CONOPS XT2100HS V 4 .0 3.1 EU Stamp EDSHB00102 Nuctech XT2100HS DHV 1.1 V3.1.40 n/a Beumer CrisBag V3 SB art.no.419B629.XXX CONOPS XT2100HS V4.0 3.1 EU Stamp EDSHB00103 Rapiscan RTT110 RTT110 EDS v1.0.50 8.14 On belt Daifuku Logan BTSP0007001A BigBear BBF11012 n/a 3 EU Stamp EDSHB00104 Leidos MV3D 1000-10001-D2 10.1.2 H100 n/a On belt n/a 3.1 EU Stamp EDSHB00105 Rapiscan RTT110 RTT110 EDS 1.0.64 8.14 Tray: Beumer Crisbag V5 SBT No 7308972 n/a 3 EU Stamp EDSHB00106 SureScan x1000 (0.5 m/s configuration) x1000 – HiSpeed.5 (Stationary Gantry) 5.5.0.0 n/a Tray: Vanderlande No 001036-103-00001 x1000B-i1310-C01 3 EU Stamp EDSHB00107 SureScan x1000 (0.5 m/s configuration) x1000 – HiSpeed.5 (Stationary Gantry) 5.5.0.1 n/a Tray: Vanderlande No 001036-103-00001 x1000B-i1310-C01 3.1 EU Stamp EDSHB00108 SureScan x1000 (0.5 m/s configuration) x1000 – HiSpeed.5 (Stationary Gantry) 5.5.0.1 n/a Tray: CrisBag® V5 SBT 507B595.XXX x1000B-i1310-C01 3 EU Stamp EDSHB00109 Nuctech WooKong H WooKong H DHV 2.0 V3.1.47 n/a On belt V2.0 (30-11-2020) 3 EU Stamp EDSHB00110 Nuctech WooKong H DHV 2.0 WooKong H DHV 2.0 V3.1.49 n/a On belt V2.0 (30-11-2020) 3.1 EU Stamp EDSHB00111 Rapiscan RTT110 RTT110 EDS 1.0.64 8.14 Tray: Vanderlande OBT Tote No 001036-278-00001 n/a 3 EU Stamp EDSHB00112 Rapiscan RTT110 RTT110 1.0.67 8.14 On belt; HKIA Utility tray Rapiscan P/N 101038931; Rapiscan Standard Utility tray P/N 101049996 Utz Bekon tray 3-122. 7000.xxxx; TTP 238/959 tray Rapiscan P/N 101038932; Daifuku Logan tray BTSP0007001A; Big Bear tray BBF11012 Beumer Crisbag V5 SBT No 7308972 RTT ECAC ConOps V1.0 8 Sept 2020 3 EU Stamp EDSHB00113 Nuctech XT2100HS XT2100HS DHV 1.1 v3.1.57 n/a Tray: Siemens (80 2002 514) XT2100HS v3.5a 3.1 EU Stamp EDSHB00114 Nuctech XT2100HS XT2100HS DHV 1.1 v3.1.56 n/a Tray: AENA.SPC-01 Tray: Congost-FT-80401 XT2100HS v3.5a 3.1 EU Stamp EDSHB00115 SureScan x1000 (0.5 m/s configuration) x1000 – HiSpeed.5 (Stationary Gantry) 5.6.0.1 n/a On belt; Tray Beumer OOG 2600 x 900 P/N 40002507913 x1000-i1310-D00 3 EU Stamp EDSHB00116 SureScan x1000 (0.5 m/s configuration) x1000 – HiSpeed.5 (Stationary Gantry) 5.6.0.2 n/a On belt x1000-i1310-D00 3.1 EU Stamp EDSHB00117 Smiths Detection HI-SCAN 10080 XCT HS 10080 XCT 09-63-09 n/a Beumer CrisBag NG Tray V3 (P/N 419B629); Beumer CrisBag V5 LBT (P/N 507B596) n/a 3 EU Stamp EDSHB00118 Nuctech XT2100HS XT2100HS DHV 1.1 v3.1.51 n/a On belt XT2100HS CONOPS v4.0 3.1 EU Stamp EDSHB00119 Smiths Detection HI-SCAN 10080 XCT HS 10080 XCT 10-33-00 n/a Tray: Beumer CrisBag NG Tray V3 (P/N 419B629); Tray: Beumer CrisBag V5 LBT (P/N 507B596); Tray: Vanderlande Wanne Leipzig n/a 3.1 EU Stamp EDSHB00120 Smiths Detection HI-SCAN 10080 XCT HS 10080 XCT 10-32-00 n/a Tray: AENA.MAD-001; Tray: Vanderlande Ref: 001036-241-00002; Tray: Vanderlande Ref: 001036-103-00001 Rev B01; Tray: Vanderlande Ref: 001036-103-00001 Rev C01; On belt n/a 3.1 EU Stamp EDSHB00121 Nuctech WooKong H WooKong H DHV 2.1 V3.1.60 n/a Tray Vanderlande Ref: 001036-241-00002; Tray Vanderlande Ref: 001036-103-00001 Rev B01; Tray Vanderlande Ref: 001036-103-00001 Rev C01 V3.0 3.1 EU Stamp EDSHB00122 Nuctech WooKong H WooKong H DHV 2.1 V3.1.61 n/a Tray: Vanderlande OBT (P/N: 001036-278-00001) V3.0 3.1 EU Stamp EDSHB00123 Nuctech WooKong H WooKong H DHV 2.1 V3.1.62 n/a On belt V3.0 3.1 EU Stamp EDSHB00124 Nuctech XT2100HS XT2100HS DHV 3.0 V3.1.58 n/a On belt XT2100HS CONOPS v4.0 3.1 EU Stamp EDSHB00125 Nuctech XT2100L XT2100L DHV 1.0 V3.1.58 n/a On belt XT2100L v1.0 3.1 EU Stamp EDSHB00127 SureScan x1000 (0.5 m/s configuration) x1000 – HiSpeed.5 (Stationary Gantry) 200000009900B 5.8.0.2; 5.8.0.5 n/a Beumer OOG 2600 x 900 (P/N 40002507913) x1000-i1310- D00 3.1 EU Stamp EDSHB00128 SureScan x1000 (0.5 m/s configuration) x1000 – HiSpeed.5 (Stationary Gantry) 200000009900B 5.8.0.5 n/a Beumer CrisBag V5 SBT (P/N 507B595.XXX) x1000-i1310-D00 3.1 EU Stamp EDSHB00129 Nuctech XT2100HS XT2100HS DHV 1.1 v3.1.38 n/a AENA.MAD-01 XT2100HS_CONOPS_v3.5_20181115 3.1 EU Stamp EDSHB00131 Leidos MV3D 1000-10001-D2 10.1.2 H100 n/a Tray: Leidos 1600mm (0190-40545-00); Tray: Big Bear BBF11012 (0190-40703-00) n/a 3 EU Stamp EDSHB00132 Smiths Detection HI-SCAN 10080 XCT HS 10080 XCT 10-34-00 n/a Tray: Siemens Logistics S-Tray, No 80.2002.514-00, Rev. G and H.;Tray: Beumer CrisBag 5 SBT Antistatic (P/N 7325131); Tray: Beumer CrisBag 5 LBT Antistatic (P/N 7325132) n/a 3.1 EU Stamp EDSHB00133 Smiths Detection HI-SCAN 10080 XCT HS 10080 XCT 10-40-00 n/a Tray: On belt; Tray Vanderlande Ref: 001036-241-00002; Tray Vanderlande Ref: 001036-103-00001 Rev B01; Tray Vanderlande Ref: 001036-103-00001 Rev C01; Tray: AENA.MAD-001; Tray: Beumer CrisBag NG Tray V3 n/a 3.1 EU Stamp EDSHB00134 Analogic SeleCT 10-79611-02 12.02.30 n/a n/a 16-120373 3.1 EU Stamp EDSHB00135 Analogic SeleCT 10-79611-02 12.02.34 n/a BigBear P/N BBF11012; Beumer CrisBag OBTL. Article No 10468579; Beumer CrisBag 5 SBT Article No 7308972 16-120373 3.1 EU Stamp EDSHB00136 Smiths Detection SDX 10080 SCT SDX 10080 SCT; SDX 10080 SCT LS 60-10-00 n/a On belt n/a 3.1 EU Stamp EDSHB00137 Nuctech WooKong G DHV 1.0 V3.1.68 n/a On belt V1.0 3.1 EU Stamp 4.2 EDS for cabin baggage The concept of operations applied for EDS for cabin bags equipment depends on the standard achieved. Standard C1 : screening requires the divestment of electronics and liquids, aerosols and gels (LAGs). Standard C2 : allows screening of baggage containing portable computers and other large electrical items. Standard C3 : allows screening of baggage containing portable computers and other large electrical items and LAGs. Standard C4 : same concept of operations as Standard C3. Unique identifier Manufacturer Designation Detailed configuration Standard Status Hardware Detection algorithm System software Auxiliary hardware Concept of operations EDSCB00001 Smiths Detection HI-SCAN 6040aTiX 6040aTiX 09-12-23 n/a Schoeller Allibert tray 2A021 (P/N 11112352) 95595885 (2016/09/26) C1 EU Stamp EDSCB00002 SureScan Detect 1000 Detect 1000 (P/N1000A100001) DETECT 1000S (P/N 200-0143-00) 200.3.0 n/a MacDonald Humfrey tray: (P/N 12043-SLT) CONOPS 1 SRT C2 EU Stamp EDSCB00003 SureScan Detect 1000 Detect 1000 (P/N1000A100001) DETECT 1000S (P/N 200-0143-00) 200.3.0 n/a Daifuku tray: SSL01_XA001_NH CONOPS 1 SRT C2 EU Stamp EDSCB00004 Leidos ClearScan 1000-10001-CS EDS_1.2.5 n/a Herbert tray: 91280AS 8100-26282-OM C2 EU Stamp EDSCB00005 Leidos ClearScan 1000-10001-CS EDS_1.2.5 n/a MacDonald Humfrey tray: (P/N 12043-SLT) 8100-26282-OM C2 EU Stamp EDSCB00006 Leidos ClearScan 1000-10001-CS EDS_1.2.5 n/a Daifuku tray (P/N SSL01_XA001_NH); Daifuku tray (P/N SSL01_XA001_NH_B); Daifuku tray (P/N SSL01_XA001_NH_C) 8100-26282-OM C2 EU Stamp EDSCB00007 Smiths Detection HI-SCAN 6040-2is HR 6040-2is HR 09-15-17 n/a Schoeller Allibert tray 2A021 (P/N 11112352) 95595885 (2016/09/26) C1 EU Stamp EDSCB00008 Smiths Detection HI-SCAN 6040-2is HR 6040-2is HR 09-15-17 n/a Herbert Tray 91280AS (P/N 34460688) 95595885 (2016/09/26) C1 EU Stamp EDSCB00009 Smiths Detection HI-SCAN 6040-2is HR 6040-2is HR 09-15-20 n/a Schoeller Allibert tray 2A021 (P/N 11112352) 95595885 (2016/09/26) C1 EU Stamp EDSCB00010 Smiths Detection HI-SCAN 6040-2is HR 6040-2is HR 09-15-19 n/a Herbert Tray 91280AS (P/N 34460688) 95595885 (2016/09/26) C1 EU Stamp EDSCB00011 Smiths Detection HI-SCAN 6040aTiX 6040aTiX 09-15-12 n/a Schoeller Allibert tray 2A021 (P/N 11112352) 95595885 (2016/09/26) C1 EU Stamp EDSCB00012 Smiths Detection HI-SCAN 6040aTiX 6040aTiX 09-15-13 n/a Schoeller Allibert tray 2A021 (P/N 11112352) 95595885 (2016/09/26) C1 EU Stamp EDSCB00013 Smiths Detection HI-SCAN 6040aTiX 6040aTiX 09-16-23 n/a Herbert Tray 91280AS (P/N 34460688) 95595885 (2016/09/26) C2 EU Stamp EDSCB00014 Smiths Detection HI-SCAN 6040aTiX 6040aTiX 09-16-23 n/a Schoeller Allibert tray 2A021 (P/N 11112352) 95595885 (2016/09/26) C2 EU Stamp EDSCB00015 Smiths Detection HI-SCAN 6040aTiX 6040aTiX 09-15-12 n/a Herbert Tray 91280AS (P/N 34460688) 95595885 (2016/09/26) C1 EU Stamp EDSCB00016 Smiths Detection HI-SCAN 6040aTiX 6040aTiX 09-15-13 n/a Herbert Tray 91280AS (P/N 34460688) 95595885 (2016/09/26) C1 EU Stamp EDSCB00017 Smiths Detection HI-SCAN 7555aTiX 7555aTiX 09-15-14 n/a Herbert Tray 91280AS (P/N 34460688) 95595885 (2016/09/26) C1 EU Stamp EDSCB00018 Smiths Detection HI-SCAN 7555aTiX 7555aTiX 09-15-14 n/a Schoeller Allibert tray 2A021 (P/N 11112352) 95595885 (2016/09/26) C1 EU Stamp EDSCB00019 Smiths Detection HI-SCAN 7555aTiX 7555aTiX 09-15-16 n/a Schoeller Allibert tray 2A021 (P/N 11112352) 95595885 (2016/09/26) C1 EU Stamp EDSCB00020 Smiths Detection HI-SCAN 7555aTiX 7555aTiX 09-16-26 n/a Schoeller Allibert tray 2A021 (P/N 11112352) 95595885 (2016/09/26) C2 EU Stamp EDSCB00021 Smiths Detection HI-SCAN 7555aTiX 7555aTiX 09-17-16 n/a Herbert Tray 91280AS (P/N 34460688) 95595885 (2016/09/26) C1 EU Stamp EDSCB00022 Smiths Detection HI-SCAN 7555aTiX 7555aTiX 09-17-26 n/a Herbert Tray 91280AS (P/N 34460688) 95595885 (2016/09/26) C2 EU Stamp EDSCB00023 Smiths Detection XDi XDi XDi-CBS-C-v1.0 n/a MacDonald Humfrey Tray (P/N 34460689) 2.13 C1 EU Stamp EDSCB00024 Analogic ConneCT n/a 9.04 n/a Daifuku tray (P/N 21-06027-01) 16-01519 Rev.00-2016 C2 EU Stamp EDSCB00025 Smiths Detection HI-SCAN 6040-2is HR 6040-2is HR 09-15-20 n/a Smiths Detection Tray (P/N 34486990); Smiths Detection tray 2 (P/N 34482148); Smiths Detection tray 2 (P/N 34506084) 95595885 (2016/09/26) C1 EU Stamp EDSCB00026 Smiths Detection HI-SCAN 6040aTiX 6040aTiX 09-16-23 n/a Smiths Detection Tray (P/N 34486990); Smiths Detection tray 2 (P/N 34482148); Smiths Detection tray 2 (P/N 34506084) 95595885 (2016/09/26) C2 EU Stamp EDSCB00027 SureScan Detect 1000 Detect 1000 (P/N1000A100001) DETECT 1000S (P/N 200-0143-00) 201.1.1 n/a MacDonald Humfrey tray (P/N 12043-SLT) Detect 1000 user guide Revision 3.0 C2 EU Stamp EDSCB00028 SureScan Detect 1000 Detect 1000 (P/N1000A100001) DETECT 1000S (P/N 200-0143-00) 201.1.1 n/a Daifuku tray: SSL01_XA001_NH Detect 1000 user guide Revision 3.0 C2 EU Stamp EDSCB00029 Leidos ClearScan 1000-10001-CS EDS_1.4.14 n/a Herbert tray: 91280AS 8100-26282-OM LAGs may be screened with a limit of the max vol of individual LAG containers not to exceed 100 ml C3 EU Stamp EDSCB00030 Leidos ClearScan 1000-10001-CS EDS_1.4.15 n/a Daifuku tray (P/N SSL01_XA001_NH); Daifuku tray (P/N SSL01_XA001_NH_B); Daifuku tray (P/N SSL01_XA001_NH_C) 8100-26282-OM LAGs may be screened with a limit of the max vol of individual LAG containers not to exceed 100 ml C3 EU Stamp EDSCB00031 Leidos ClearScan 1000-10001-CS EDS_1.4.18 n/a MacDonald Humfrey tray (P/N 12043-SLT) 8100-26282-OM LAGs may be screened with a limit of the max vol of individual LAG containers not to exceed 100 ml C3 EU Stamp EDSCB00032 Nuctech Kylin DHV 1.0 v3.5.7 n/a Vanderlande Scannojet Tray v4 P10128 revA v1.0 C1 EU Stamp EDSCB00033 Nuctech Kylin DHV 1.0 v3.5.9 n/a Vanderlande Scannojet Tray v4 P10128 revA v1.0 C1 EU Stamp EDSCB00034 Analogic ConneCT ConneCT 9.07 n/a Daifuku tray (P/N 21-06027-01) 16-01519 Rev.00-2016 C2 EU Stamp EDSCB00035 Gilardoni FEP ME 640 AMX 37548400-001 3AUE0294-005 n/a Gilardoni Tray (P/N 55203181) 37640500-001 37640500-004 C1 EU Stamp EDSCB00036 Smiths Detection HI-SCAN 6040 CTiX 6040 CTiX; 6040 CTiX Model S 20-10-00 n/a MacDonald Humfrey tray (P/N 34460689) 95596016 (2017/09/26) C2 EU Stamp EDSCB00037 Smiths Detection HI-SCAN 6040aTiX 6040aTiX 09-18-13 n/a MacDonald Humfrey tray (P/N 34460689) 95595885 (2016/09/26) C1 EU Stamp EDSCB00038 Smiths Detection HI-SCAN 6040aTiX 6040aTiX 09-18-24 n/a MacDonald Humfrey tray (P/N 34460689) 95595885 (2016/09/26) C2 EU Stamp EDSCB00039 Rapiscan 920CT n/a 9.04 n/a Daifuku tray (P/N 21-06027-01) 101014944 Rev 2 C2 EU Stamp EDSCB00040 Rapiscan 920CT n/a 9.07 n/a Daifuku tray (P/N 21-06027-01) 101014944 Rev 2 C2 EU Stamp EDSCB00041 Smiths Detection HI-SCAN 6040 CTiX 6040 CTiX; 6040 CTiX Model S 20-14-00 n/a Daifuku tray (P/N SSL01_XA003_NH); Daifuku tray (P/N SSL01_XA004_NH) 95596016 (2017/09/26) C1 EU Stamp EDSCB00042 Smiths Detection HI-SCAN 6040 CTiX 6040 CTiX; 6040 CTiX Model S 20-14-00 n/a Smiths Detection tray (P/N 34486990); Smiths Detection tray 2 (P/N 34482148); Smiths Detection tray 2 (P/N 34506084) 95596016 (2017/09/26) C1 EU Stamp EDSCB00043 Smiths Detection HI-SCAN 6040 CTiX 6040 CTiX; 6040 CTiX Model S 20-20-00 n/a MacDonald Humfrey tray (P/N 34460689) 95596016 (2017/09/26) C2 EU Stamp EDSCB00044 Smiths Detection HI-SCAN 6040 CTiX 6040 CTiX; 6040 CTiX Model S 20-20-00 n/a Daifuku tray (P/N SSL01_XA003_NH); Daifuku tray (P/N SSL01_XA004_NH) 95596016 (2017/09/26) C1 EU Stamp EDSCB00045 Smiths Detection HI-SCAN 6040 CTiX 6040 CTiX; 6040 CTiX Model S 20-20-00 n/a Smiths Detection tray (P/N 34486990); Smiths Detection tray 2 (P/N 34482148); Smiths Detection tray 2 (P/N 34506084) 95596016 (2017/09/26) C1 EU Stamp EDSCB00046 SureScan Detect 1000 Detect 1000 (P/N1000A100001) DETECT 1000S (P/N 200-0143-00) 314.0.1 n/a MacDonald Humfrey tray: (P/N 12043-SLT) Detect 1000 user guide Revision 3.0 LAGs may be screened with a limit of the max vol of individual LAG containers not to exceed 100 ml C3 EU Stamp EDSCB00047 SureScan Detect 1000 Detect 1000 (P/N1000A100001) DETECT 1000S (P/N 200-0143-00) 314.0.1 n/a Daifuku tray: SSL01_XA001_NH Detect 1000 user guide Revision 3.0 LAGs may be screened with a limit of the max vol of individual LAG containers not to exceed 100 ml C3 EU Stamp EDSCB00048 SureScan Detect 1000 Detect 1000 (P/N1000A100001) DETECT 1000S (P/N 200-0143-00) 205.0.0 n/a Daifuku tray: SSL01_XA001_NH Detect 1000 user guide Revision 3.0 C2 EU Stamp EDSCB00049 SureScan Detect 1000 Detect 1000 (P/N1000A100001) DETECT 1000S (P/N 200-0143-00) 205.0.0 n/a MacDonald Humfrey tray: (P/N 12043-SLT) Detect 1000 user guide Revision 3.0 C2 EU Stamp EDSCB00050 Nuctech CX6040D CX6040D Eda V1.0.0 n/a Nuctech NUC680 tray (P/N v1) CONOPS CX6040D V1.0 C1 EU Stamp EDSCB00051 Nuctech CX6040D CX6040D Eda V1.0.0 n/a Vanderlande Scannojet tray v4 P10128 RevA CONOPS CX6040D V1.0 C1 EU Stamp EDSCB00052 Smiths Detection HI-SCAN 6040 CTiX 6040 CTiX; 6040 CTiX Model S 20-27-00 n/a MacDonald Humfrey tray (P/N 34460689) 95596016 (2017/09/26) LAGs may be screened with a limit of the max vol of individual LAG containers not to exceed 100 ml C3 EU Stamp EDSCB00053 Smiths Detection HI-SCAN 6040 CTiX 6040 CTiX; 6040 CTiX Model S 20-27-00 n/a Smiths Detection tray P/N 34486990); Smiths Detection tray 2 (P/N 34482148) Smiths Detection tray 2 (P/N 34506084) 95596016 (2017/09/26) LAGs may be screened with a limit of the max vol of individual LAG containers not to exceed 100 ml C3 EU Stamp EDSCB00054 Smiths Detection HI-SCAN 6040aTiX 6040aTiX 09-19-23 n/a Vanderlande Scannojet tray (P/N 10128 / 095527-727) 95596016 C1 EU Stamp EDSCB00055 Analogic ConneCT ConneCT 9.07 n/a Herbert tray (P/N 42112482) 16-01519 Rev.03-2018 C2 EU Stamp EDSCB00056 Analogic ConneCT ConneCT 9.11 n/a Vanderlande tray (P/N 095527-727) 16-01519 Rev.03-2018 C2 EU Stamp EDSCB00057 Leidos ClearScan 1000-10001-CS EDS_1.4.25 n/a MacDonald Humfrey tray: (P/N 12043-SLT) 8100-26282-OM LAGs may be screened with a limit of the max vol of individual LAG containers not to exceed 100 ml C3 EU Stamp EDSCB00058 Leidos ClearScan 1000-10001-CS EDS_1.4.25 n/a Daifuku tray (P/N SSL01_XA001_NH); Daifuku tray (P/N SSL01_XA001_NH_B); Daifuku tray (P/N SSL01_XA001_NH_C) 8100-26282-OM C3 EU Stamp EDSCB00059 Nuctech Kylin Ti DHV 1.0 v3.6.10 n/a Nuctech NUC680 tray (P/N v1) Kylin Ti v1.0 Kylin Ti CONOPS v3.0 LAGs may be screened with a limit of the max vol of individual LAG containers not to exceed 100 ml C3 EU Stamp EDSCB00060 Rapiscan 620DV n/a 4.517 n/a MacDonald Humfrey tray (P/N 101005244) D00370 Rev.1 C1 EU Stamp EDSCB00061 Rapiscan 920CT n/a 9.07 n/a Herbert tray (P/N 42112482) 101014944 Rev 2 C2 EU Stamp EDSCB00062 Rapiscan 920CT n/a 9.11 n/a Vanderlande tray (P/N 095527-727) 101014944 Rev 2 C2 EU Stamp EDSCB00063 Smiths Detection HI-SCAN 6040 CTiX 6040 CTiX; 6040 CTiX Model S 20-31-00 n/a Smiths Detection tray (P/N 34486990) 95596016 Rev. 1 (2017/09/26) LAGs may be screened with a limit of the max vol of individual LAG containers not to exceed 100 ml C3 EU Stamp EDSCB00064 Smiths Detection HI-SCAN 6040 CTiX 6040 CTiX; 6040 CTiX Model S 20-30-00 n/a MacDonald Humfrey tray (P/N 34460689) 95596016 Rev. 1 (2017/09/26) LAGs may be screened with a limit of the max vol of individual LAG containers not to exceed 100 ml C3 EU Stamp EDSCB00065 Smiths Detection HI-SCAN 6040 CTiX 6040 CTiX; 6040 CTiX Model S 20-30-00 n/a Daifuku tray (P/N SSL01_XA003_NH); Daifuku tray (P/N SSL01_XA004_NH) 95596016 Rev. 1 (2017/09/26) LAGs may be screened with a limit of the max vol of individual LAG containers not to exceed 100 ml C3 EU Stamp EDSCB00066 Smiths Detection HI-SCAN 6040 CTiX 6040 CTiX; 6040 CTiX Model S 20-30-00 n/a Smiths Detection tray (P/N 34486990) 95596016 Rev. 1 (2017/09/26) LAGs may be screened with a limit of the max vol of individual LAG containers not to exceed 100 ml C3 EU Stamp EDSCB00067 Smiths Detection HI-SCAN 6040 CTiX 6040 CTiX; 6040 CTiX Model S 20-31-00 n/a Daifuku tray (P/N SSL01_XA003_NH); Daifuku tray (P/N SSL01_XA004_NH) 95596016 Rev. 1 (2017/09/26) LAGs may be screened with a limit of the max vol of individual LAG containers not to exceed 100 ml C3 EU Stamp EDSCB00068 Smiths Detection HI-SCAN 6040 CTiX 6040 CTiX; 6040 CTiX Model S 20-31-00 n/a MacDonald Humfrey tray (P/N 34460689) 95596016 Rev. 1 (2017/09/26) LAGs may be screened with a limit of the max vol of individual LAG containers not to exceed 100 ml C3 EU Stamp EDSCB00069 Smiths Detection HI-SCAN 6040-2is HR 6040-2is HR 09-19-19 n/a Vanderlande tray (P/N P10128 / 095527-727) 95596016 (2017/09/26) C1 EU Stamp EDSCB00070 Smiths Detection HI-SCAN 6040aTiX 6040aTiX 09-15-13 n/a Smiths Detection tray (P/N 34486990); Smiths Detection tray 2 (P/N 34482148); Smiths Detection tray 2 (P/N 34506084) 95595885 (2016/09/26) C1 EU Stamp EDSCB00071 Analogic ConneCT ConneCT 9.15.01 n/a Vanderlande tray (P/N 095527-727) 16-01519 Rev.03-2018 C2 EU Stamp EDSCB00072 Analogic ConneCT ConneCT 9.15.01 n/a Herbert tray (P/N 42112482) 16-01519 Rev.03-2018 C2 EU Stamp EDSCB00073 Analogic ConneCT ConneCT 9.15.01 n/a MacDonald Humfrey tray (P/N 12043-SLT) 16-01519 Rev.03-2018 C2 EU Stamp EDSCB00074 Analogic ConneCT ConneCT 9.17.02 n/a Herbert tray (P/N 42112482) 16-01519 Rev.03-2018 LAGs may be screened with a limit of the max vol of individual LAG containers not to exceed 100 ml C3 EU Stamp EDSCB00075 Analogic ConneCT ConneCT 9.17.02 n/a MacDonald Humfrey tray (P/N 12043-SLT) 16-01519 Rev.03-2018 LAGs may be screened with a limit of the max vol of individual LAG containers not to exceed 100 ml C3 EU Stamp EDSCB00076 Analogic ConneCT ConneCT v9.17.01 n/a Vanderlande tray (P/N 095527-727) 16-01519 Rev.03-2018 LAGs may be screened with a limit of the max vol of individual LAG containers not to exceed 100 ml C3 EU Stamp EDSCB00077 Nuctech Kylin MV DHV 1.0 v7.0.3 n/a Vanderlande Scannojet Tray v4 P10128 revA EDSCB and LEDS V2.0 C2 EU Stamp EDSCB00078 Nuctech Kylin MV DHV 1.0 v7.0.3 n/a Nuctech NUC680 tray (P/N v1) EDSCB and LEDS V2.0 C2 EU Stamp EDSCB00079 Nuctech Kylin Ti DHV 1.0 v3.6.10 n/a Vanderlande Scannojet Tray v4 P10128 revA Kylin Ti v1.0 Kylin Ti CONOPS v3.0 LAGs may be screened with a limit of the max vol of individual LAG containers not to exceed 100 ml C3 EU Stamp EDSCB00080 Rapiscan 920CT n/a 9.15.01 n/a Herbert tray (P/N 42112482) 101014944 Rev 2 C2 EU Stamp EDSCB00081 Rapiscan 920CT n/a 9.15.01 n/a Vanderlande tray (P/N 095527-727) 101014944 Rev 2 C2 EU Stamp EDSCB00082 Rapiscan 920CT n/a 9.15.01 n/a MacDonald Humfrey tray (P/N 12043-SLT) 101014944 Rev 2 C2 EU Stamp EDSCB00083 Rapiscan 920CT n/a 9.17.02 n/a Herbert tray (P/N 42112482) 101014944 Rev 2 LAGs may be screened with a limit of the max vol of individual LAG containers not to exceed 100 ml C3 EU Stamp EDSCB00084 Rapiscan 920CT n/a 9.17.02 n/a MacDonald Humfrey tray (P/N 12043-SLT) 101014944 Rev 2 LAGs may be screened with a limit of the max vol of individual LAG containers not to exceed 100 ml C3 EU Stamp EDSCB00085 Rapiscan 920CT n/a 9.17.01 n/a Vanderlande tray (P/N 095527-727) 101014944 Rev 2 LAGs may be screened with a limit of the max vol of individual LAG containers not to exceed 100 ml C3 EU Stamp EDSCB00086 Smiths Detection HI-SCAN 6040aTiX 6040aTiX 09-70-23 n/a Vanderlande Scannojet tray (P/N P10128 / 095527-727) 95596016 C2 EU Stamp EDSCB00087 SureScan Detect 1000 Detect 1000 (P/N1000A100001) DETECT 1000S (P/N 200-0143-00) 326.0.0 n/a Tray: VanDerLande Bandeja Scannojet Mfg. No 1000D1000v4.0 LAGs may be screened with a limit of the max vol of individual LAG containers not to exceed 100 ml C3 EU Stamp EDSCB00088 Smiths Detection HI-SCAN 6040 CTiX 6040 CTiX; 6040 CTiX Model S 20-30-00 n/a Smiths Detection tray 2 (P/N 34482148); Smiths Detection tray 2 (P/N 34506084) Vanderlande (P10128 / 095527-727) 95596016 Rev.1 (2017/09/26) LAGs may be screened with a limit of the max vol of individual LAG containers not to exceed 100 ml C2 and C3 EU Stamp EDSCB00089 Analogic ConneCT ConneCT 9.19.04 n/a Herbert (P/N 42112482) MacDonald Humfrey (P/N 12043-SLT) Vanderlande (P/N 095527-727) 16-01519-rev03-2018 LAGs may be screened with a limit of the max vol of individual LAG containers not to exceed 100 ml C3 EU Stamp EDSCB00090 Rapiscan 920CT n/a 9.19.04 n/a Herbert tray (P/N 42112482) MacDonald Humfrey tray (P/N 12043-SLT) Vanderlande tray (P/N 095527-727) 101014944 Rev 2 LAGs may be screened with a limit of the max vol of individual LAG containers not to exceed 100 ml C3 EU Stamp EDSCB00091 Smiths Detection HI-SCAN 6040 CTiX 6040 CTiX; 6040 CTiX Model S 20-36-00 n/a Smiths tray (P/N 34486990) Mac Donald Humfrey (P/N34460689) Daifuku (P/N SSL01_XA003_NH); Daifuku tray (P/N SSL01_XA004_NH) 95596016 LAGs may be screened with a limit of the max vol of individual LAG containers not to exceed 100 ml C3 EU Stamp EDSCB00092 Smiths Detection HI-SCAN 6040 CTiX 6040 CTiX; 6040 CTiX Model S 20-41-00 n/a Smiths (P/N 34486990) Mac Donald Humfrey (P/N34460689) Daifuku (P/N SSL01_XA003_NH); Daifuku tray (P/N SSL01_XA004_NH) 95596016 LAGs may be screened with a limit of the max vol of individual LAG containers not to exceed 100 ml C3 EU Stamp EDSCB00093 SureScan Detect 1000 Detect 1000 (P/N1000A100001) DETECT 1000S (P/N 200-0143-00) 326.0.0 n/a OneTray Tray (P/N OT_VAS007) OneTray (P/N OT-VAS013) OneTray (P/N OT-VAS015) OneTray (P/N OT-VAS016) IDSS_REP-077_Detect1000_ConOps_Rev0 LAGs may be screened with a limit of the max vol of individual LAG containers not to exceed 100 ml C3 EU Stamp EDSCB00094 Nuctech CX7555D CX7555D.A03N EDA 1.0.2 n/a Nuctech NUC680 tray (P/N v3); Vanderlande Scannojet tray 95527-727 (P10128 revA); MacDonald Humfrey tray (12043-SLT) CONOPS_CX7555D_EDSCB_V1.0_20190716 C1 EU Stamp EDSCB00095 Leidos ClearScan HS 1000-10001-CSU EDS-1.4.33 n/a Vanderlande (P/N 095527-727) 8100-34802 OM LAGs may be screened with a limit of the max vol of individual LAG containers not to exceed 100 ml C3 EU Stamp EDSCB00096 Leidos ClearScan HS 1000-10001-CSU EDS-1.4.41 n/a MacDonald Humfrey tray (P/N 12043-SLT) 8100-34802 OM LAGs may be screened with a limit of the max vol of individual LAG containers not to exceed 100 ml C3 EU Stamp EDSCB00097 Leidos ClearScan HS 1000-10001-CSU EDS-1.4.42 n/a Daifuku tray (P/N SSL01_XA001_NH); Daifuku tray (P/N SSL01_XA001_NH_B); Daifuku tray (P/N SSL01_XA001_NH_C) 8100-34802 OM LAGs may be screened with a limit of the max vol of individual LAG containers not to exceed 100 ml C3 EU Stamp EDSCB00098 SureScan Detect 1000 Detect 1000 (P/N1000A100001) DETECT 1000S (P/N 200-0143-00) 329.0.0 n/a Herbert tray (P/N 91280AS) Mfg. No 1000D1000v4.0 LAGs may be screened with a limit of the max vol of individual LAG containers not to exceed 100 ml C3 EU Stamp EDSCB00099 SureScan Detect 1000 Detect 1000 332.1.0 n/a Cassioli tray (P/N S030012FPLT) WO tray (P/N W-280819-000) IDSS_REP-077_Detect1000_ConOps_Rev0 LAGs may be screened with a limit of the max vol of individual LAG containers not to exceed 100 ml C3 EU Stamp EDSCB00100 Nuctech Kylin Ti Kylin Ti DHV 1.0 v3.6.12 n/a Nuctech NUC680 tray (P/N v3) Kylin Ti CONOPS v1.2 Kylin Ti CONOPS v3.0 LAGs may be screened with a limit of the max vol of individual LAG containers not to exceed 100 ml C3 EU Stamp EDSCB00101 Nuctech Kylin Ti Kylin Ti DHV 1.0 v3.6.13 n/a Cassioli tray (P/N S030008FPLT) Kylin Ti CONOPS v1.2 Kylin Ti CONOPS v3.0 LAGs may be screened with a limit of the max vol of individual LAG containers not to exceed 100 ml C3 EU Stamp EDSCB00102 Smiths Detection HI-SCAN 6040-2is HR 6040-2is HR 09-15-20 n/a Smiths Detection tray 3 (P/N 34493797); Smiths Detection tray 3 (P/N 34495373) Smiths Detection tray 3 (P/N 34496512) 95596016 rev. 02 (2020/03/01) C1 EU Stamp EDSCB00103 Analogic ConneCT ConneCT v9.23.05 n/a Herbert tray (P/N 101019470) 16-01519 Rev.03-2018 LAGs may be screened with a limit of the max vol of individual LAG containers not to exceed 100 ml C3 EU Stamp EDSCB00104 Analogic ConneCT ConneCT v9.21.09 n/a Vanderlande tray (P/N 095527-727) 16-01519 Rev.03-2018 C3 EU Stamp EDSCB00105 Analogic ConneCT ConneCT v9.23.04 n/a MacDonald Humfrey (P/N 12043-SLT) 16-01519 Rev.03-2018 LAGs may be screened with a limit of the max vol of individual LAG containers not to exceed 100 ml C3 EU Stamp EDSCB00106 Nuctech Kylin Ti DHV 2.0 V3.6.23 n/a Alfyma tray (P/N RDBA18-PART-000-B) Vanderlande Scannojet tray (P/N 095527-727 / P10128 revA) MacDonald Humfrey tray (P/N 12043-SLT) Kylin Ti – CONOPS v1.2 (2019/07/03) Kylin Ti CONOPS v3.0 LAGs may be screened with a limit of the max vol of individual LAG containers not to exceed 100 ml C3 EU Stamp EDSCB00107 Rapiscan 920CT 920CT v9.23.05 n/a Herbert tray (P/N 101019470) 101014944 Rev 2 LAGs may be screened with a limit of the max vol of individual LAG containers not to exceed 100 ml C3 EU Stamp EDSCB00108 Rapiscan 920CT 920CT v9.21.09 n/a Vanderlande tray (P/N 095527-727) 101014944 Rev 2 LAGs may be screened with a limit of the max vol of individual LAG containers not to exceed 100 ml C3 EU Stamp EDSCB00109 Rapiscan 920CT 920CT v9.23.04 n/a MacDonald Humfrey (P/N 12043-SLT) 101014944 Rev 2 LAGs may be screened with a limit of the max vol of individual LAG containers not to exceed 100 ml C3 EU Stamp EDSCB00110 Smiths Detection HI-SCAN 6040 CTiX 6040 CTiX; CTiX Model S 20-50-00 n/a OneTray tray (P/N OT_VAS013) Cassioli tray (P/N S030012FPLT) Smiths Detection tray 3 (P/N 34496512) Smiths Detection tray 3 (P/N 34493797) Smiths Detection tray 3 (P/N 34495373) 95596016 rev.02 (2020/03/01) LAGs may be screened with a limit of the max vol of individual LAG containers not to exceed 100 ml C3 EU Stamp EDSCB00111 Smiths Detection HI-SCAN 7555aTiX 7555aTiX 09-71-27 n/a Smiths Detection tray (P/N 34486990) 95596016 (2017/09/26) C2 EU Stamp EDSCB00112 Rapiscan 920DX 920DX 1.22 n/a Herbert tray (P/N 42112482); Vanderlande tray (P/N 095527-727); MacDonald Humfrey tray (P/N 101005244) D05150 rev1, 920DX ConOps EDSCB C1 C1 EU Stamp EDSCB00113 Rapiscan 920DX 920DX 1.23 n/a Herbert tray (P/N 42112482); Vanderlande tray (P/N 095527-727) D05150 rev1, 920DX ConOps EDSCB C1 C1 EU Stamp EDSCB00114 Rapiscan 920DX 920DX 1.25 n/a MacDonald Humfrey tray (P/N 101005244) D05150 rev1, 920DX ConOps EDSCB C1 C1 EU Stamp EDSCB00115 Nuctech Kylin MV DHV 1.0 v7.0.5 n/a NUC680 tray (P/N v3) EDSCB and LEDS V2.0 C2 EU Stamp EDSCB00116 Nuctech CX6040D CX6040D Eda V1.0.0 n/a OneTray (P/N VAS021); MacDonald Humfrey tray (12043-SLT); NUC680 tray (P/N v5) CONOPS_CX6040D_V1.0_EDSCB C1 EU Stamp EDSCB00117 Nuctech Kylin Ti DHV 2.0 V3.6.25 n/a NUC680 tray (P/N v3) Kylin Ti CONOPS v1.2; Kylin Ti CONOPS v3.0 LAGs may be screened with a limit of the max vol of individual LAG containers not to exceed 100 ml C3 EU Stamp EDSCB00118 Nuctech Kylin Ti DHV 2.0 V3.6.27 n/a Cassioli tray (P/N S030008FPLT) Kylin Ti CONOPS v1.2; Kylin Ti CONOPS v3.0 LAGs may be screened with a limit of the max vol of individual LAG containers not to exceed 100 ml C3 EU Stamp EDSCB00119 Smiths Detection HI-SCAN 6040 DV 6040DV 30-00-25 n/a Vanderlande tray (P/N 10128 / 095527-727); Smiths Detection tray 3 (SD3, P/N 34495373); Smiths Detection tray 3 (P/N 34493797); Smiths Detection tray 3 (P/N 34496512) 95596016 rev. 02 (2020/03/01) C1 EU Stamp EDSCB00120 Smiths Detection HI-SCAN 6040 DV 6040DV 30-00-38 n/a Smiths Detection tray 2 (SD2, P/N 34482148); Smiths Detection tray 2 (P/N 34506084); Smiths Detection tray 3 (SD3, P/N 34495373); Smiths Detection tray 3 (P/N 34493797); Smiths Detection tray 3 (P/N 34496512) 95596016 rev. 02 (2020/03/01) C1 EU Stamp EDSCB00121 Nuctech CX6040D CX6040D Eda V1.0.4 n/a Cassioli tray (P/N S030008FPLT); NUC680 tray (P/N V2); NUC680 tray (P/N V3) CONOPS CX6040D V1.0 C1 EU Stamp EDSCB00122 Smiths Detection HI-SCAN 7555 DV 7555 DV 30-10-16 n/a Smiths Detection tray 2 (SD2, P/N 34482148); Smiths Detection tray 2 (P/N 34506084); Smiths Detection tray 3 (SD3, P/N 34495373); Smiths Detection tray 3 (P/N 34493797); Smiths Detection tray 3 (P/N 34496512) 95596016 C1 EU Stamp EDSCB00123 Smiths Detection HI-SCAN 7555 DV 7555 DV 30-10-17 n/a Smiths Detection tray 2 (P/N 34482148); Smiths Detection tray 2 (P/N 34506084); Smiths Detection tray 3 (P/N 34495373); Smiths Detection tray 3 (P/N 34493797); Smiths Detection tray 3 (P/N 34496512); Schoeller Allibert tray 2A021(P/N 11112352) 95596016 C1 EU Stamp EDSCB00124 Nuctech Kylin Ti DHV 1.0 v3.6.8 n/a Nuctech NUC680 tray (P/N v1); Vanderlande Scannojet tray (P/N 095527- 727 / P10128 revA) Kylin Ti CONOPS v3.0 C2 EU Stamp EDSCB00125 Nuctech AX6040 A01N EDA 3.0.2 n/a NUC680 V3 v 1.0 C2 EU Stamp EDSCB00126 Nuctech AX6040 A01N EDA 3.0.7 n/a NUC680 V5 v 1.0 C2 EU Stamp EDSCB00127 SSTLabs E3S 690 E3S 690 1.4.2 n/a EV tray SSQP-06-027 Rev No 4 LAGs may be screened with a limit of the max vol of individual LAG containers not to exceed 100 ml C3 EU Stamp EDSCB00128 Smiths Detection HI-SCAN 6040 CTiX 6040 CTiX; 6040 CTiX Model S 20-71-00 n/a Cassioli tray (P/N S030012FPLT); OneTray tray (P/N OT_VAS013); Smiths Detection tray 3 (P/N 34496512); Smiths Detection tray 3 (P/N 34493797); Smiths Detection tray 3 (P/N 34495373) 95596016 – LAGs may be screened with a limit of the max vol of individual LAG containers not to exceed 2000 ml C3 EU Stamp EDSCB00129 Nuctech Kylin Ti DHV 2.0 V3.6.30 n/a NUC680 tray (P/N v5); OneTray (P/N VAS013) Kylin Ti CONOPS v1.2; Kylin Ti CONOPS v3.0 LAGs may be screened with a limit of the max vol of individual LAG containers not to exceed 100 ml C3 EU Stamp EDSCB00130 Leidos PX 640 DV 37548400-001 3AUE0294-005 n/a Leidos tray (P/N AX0190-42132-00) 37640500-004 C1 EU Stamp EDSCB00131 Leidos ClearScan HS AX1000-10001-CSU 1.4.60 n/a Cassioli (P/N: S030012FPLT) AX8100-34802-OM – LAGs may be screened with a limit of the max vol of individual LAG containers not to exceed 100 ml C3 EU Stamp 5. THREAT IMAGE PROJECTION (TIP) Left intentionally blank 6. EXPLOSIVE TRACE DETECTION (ETD) EQUIPMENT For the performance of ETD equipment, two sampling methods have been considered during the evaluation: — (H) means the equipment has passed the tests with hand swabbing; — (W) means the equipment has passed the tests with wand swabbing. For the performance of ETD equipment, two fields of use have been considered during the evaluations: — (P) means the equipment has passed the tests for the screening of passengers, persons other than passengers, items carried, cabin baggage and hold baggage; — (C) means the equipment has passed the tests for the screening of cargo and mail, in-flight supplies, airport supplies and air carrier materials loaded in the aircraft hold. For the detection capability of ETD equipment, the following indication is used: — (G1) means the ETD equipment that has achieved the chemicals detection standard G1, in addition to the previously achieved explosives detection standard. Unique identifier Manufacturer Designation Detailed configuration Standard Status Hardware Detection algorithm System software Auxiliary hardware Concept of operations ETD0000001 Smiths Detection IONSCAN 500DT 4816800 AE Rev L n/a Swab: Part Number 6822254-A Wand: P/N 6820512 6824395 (operator manual) (H) / (W) (P) / (C) EU Stamp ETD0000002 Smiths Detection IONSCAN 600 4824000 IS600 Exp ECAC-1 final ECAC E (24727-1) ECAC E (24766-1) ECAC E (24766A-1) n/a Swab: P/N 6824768-01; P/N 1824019-A IONSCAN 600 Quick Start Guide, Part Number 6824007 (H) (P) / (C) EU Stamp ETD0000003 Bruker Optics DE-tector P/N 1824953 Library B_EXEU_EXPL15 (P/N 1836524) n/a Swab: Sample Collector (P/N 8702660) Sample Collector (P/N 8702660-E) Sampling wand: 8702515 2014-06-17/Rev. 1.00 (P/N 1829977) 2016-02-01/Rev. 1.01 (P/N 1829977) (H) / (W) (P) EU Stamp ETD0000004 Bruker Optics DE-tector P/N 1824953 Library B_EXEU_EXPL16 (P/N 1836522) n/a Swab: Sample Collector (P/N 8702660) Sample Collector (P/N 8702660-E) Sampling wand: 8702515 2014-06-17/Rev. 1.00 (P/N 1829977) 2016-02-01/Rev. 1.01 (P/N 1829977) (H) / (W) (P) / (C) EU Stamp ETD0000005 Bruker Optics DE-tector P/N 1824953 Library B_EXEU_MIXD01 (P/N 1836519) n/a Swab: Sample Collector (P/N 8702660) Sample Collector (P/N 8702660-E) Sampling wand: 8702515 2014-06-17/Rev. 1.00 (P/N 1829977) 2016-02-01/Rev. 1.01 (P/N 1829977) (H) / (W) (P) EU Stamp ETD0000006 Leidos QS-B220 Mfr. P/N QS-B220-010 10011377 (System Software 1.1.8) 23176 (P/N 42300086) n/a Swab: Sample traps (P/N 42200191) Sampling wand – 10011279 42400030 (Quick Start Guide) 42400028 (User Manual) (H) / (W) (P) EU Stamp ETD0000007 Leidos QS-B220 Mfr. P/N QS-B220-011 10011377 (System Software 1.1.8) 23448 (P/N 42300099) n/a Swab: Sample traps (P/N 42200191) Sampling wand – 10011279 42400030 (Quick Start Guide) 42400028 (User Manual) (H) / (W) (P) / (C) EU Stamp ETD0000008 Leidos QS-B220 Mfr. P/N QS-B220-012 10011377 (System Software 1.1.8) 23445 (P/N 42300098) n/a Swab: Sample traps (P/N 42200191) Sampling wand – 10011279 42400030 (Quick Start Guide) 42400028 (User Manual) (H) / (W) (P) EU Stamp ETD0000009 Leidos QS-B220 Mfr. P/N QS-B220-013 10011377 (System Software 1.1.8) 23444 (P/N 42300097) n/a Swab: Sample traps (P/N 42200191) Sampling wand – 10011279 42400030 (Quick Start Guide) 42400028 (User Manual) (H) / (W) (P) / (C) EU Stamp ETD0000010 Leidos QS-B220 Mfr. P/N QS-B220-014 10011334 (System Software 1.2.0) 23445 (P/N 42300098) n/a Swab: Sample traps (P/N 42200191) Sampling wand – 10011279 42400030 (Quick Start Guide) 42400028 (User Manual) (H) / (W) (P) EU Stamp ETD0000011 Rapiscan ITEMISER 4DX P0007018-015-CEP C10.06.11-CEP n/a Swab: M0002057 Hand Wand: M0001240 MA100026-01 / MA100026-02; MA100091 Rev 0C (H) / (W) (P) EU Stamp ETD0000012 Rapiscan ITEMISER 4DX P0007018-015-CEP C10.06.14-CEP n/a Swab: M0002057 Hand Wand: M0001240 MA100026-01 / MA100026-02; MA100091 Rev 0C (H) / (W) (P) / (C) EU Stamp ETD0000013 Smiths Detection IONSCAN 600 4824000 IS600 Exp ECAC-1 final n/a Swab: P/N 6824768-01; P/N 1824019-A Operational Manual, Rev. A, May 2015, Part Number 6824005ROW (H) / (W) (P) / (C) EU Stamp ETD0000014 Rapiscan ITEMISER DX P0007018-014-CEP 8.89e13CEP n/a Swab: M0001964-100 MA100034-01 / MA100034-02; MA100034-02 Rev E (H) (P) / (C) EU Stamp ETD0000015 Bruker Optics RoadRunner P/N 1860000 B_RR00_EXPL14 n/a Swab: Sample Collector M (P/N 1842394) 2016-02-16/Rev. 1.00 (P/N 1842342) (H) (P) EU Stamp ETD0000016 Nuctech TR2000DB-A C 1.00 15.10.31.64 n/a Swab: BZOA0403000-I-02 Portable swab baker: BZOA0800000-02 7.10 (W) (P) / (C) EU Stamp ETD0000017 Smiths Detection IONSCAN 600 4824000E-101-2 4824000E-101P-2 ECAC E (24758-1) ECAC E (24758-2) ECAC E (24758-4) ECAC E (24758A-1) ECAC E (24758A-2) ECAC E (24758A-4) n/a Swab: P/N 6824768-01; P/N 1824019-A Sampling Wand (Optional): P/N 3824750-1; P/N 3824750-2 6824005ROW revision C, January 2016 6824005ROW revision D, IONSCAN 600 Quick Start Guide, P/N 6824007 (H) / (W) (P) / (C) EU Stamp ETD0000019 Nuctech TR2000DB-A C 1.00 16.8.2.64 n/a Swab: BZOA0403000-I-02 Portable swab baker: BZOA0800000-02 7.10 (W) (P) EU Stamp ETD0000020 Nuctech TR2000DB-A C 1.00 16.8.2.64: Library E11.A04.1611 Library E11.A08.1611 n/a Swab: BZOA0403000-I-02 Portable swab baker: BZOA0800000-02 7.10 (H) (P) EU Stamp ETD0000021 Nuctech TR2000DB-A NIL2.0 D17.3.16.66 (Library E11.B01.1707) n/a Swab: -04A Portable swab baker: BZOA0800000-02 v17.06 (H) (P) / (C) EU Stamp ETD0000022 Rapiscan ITEMISER 4DX P0007018-015-CEP C10.06.23-CEP n/a Swab: M0002057 MA100091 rev0A; MA100091 Rev 0C (H) (P) / (C) EU Stamp ETD0000023 Leidos QS-B220HT Mfr. P/N QS-B220-017 10011465 25088 (P/N 42300098) 1.4 (P/N 42300085) Swab: Sample traps P/N 42200191 Sampling wand P/N 10011451; Sampling wand: P/N 10011279 42400049 (Quick Start Guide) 42400048 (User Manual) (H) / (W) (P) / (C) EU Stamp ETD0000024 Bruker Optics DE-tector P/N 1824953 Library B_EXEU_EXPL19 n/a Swab: Sample Collector (P/N 8702660) Sample Collector (P/N 8702660-E) 2016-02-01/Rev. 1.01 (P/N 1829977) 2016-02-01/Rev. 1.01 (P/N 1829977) (H) (P) EU Stamp ETD0000025 Bruker Optics DE-tector P/N 1824953 Library B_EXEU_EXPL22 n/a Swab: Sample Collector (P/N 8702660) Sample Collector (P/N 8702660-E) Sampling wand: 8702515 2016-02-01/Rev. 1.01 (P/N 1829977) 2016-02-01/Rev. 1.01 (P/N 1829977) (H) / (W) (P) EU Stamp ETD0000026 Nuctech TR2000DB-A NIL2.0 D17.3.16.66 (Library E11.B02.1712) (Library E11.B05.1712) (Library E11.B06.1712) n/a Swab: -04A Portable swab baker: BZOA0403000-I-02 v17.06 (H) (P) / (C) EU Stamp ETD0000027 Rapiscan ITEMISER DX P0007018-014-CEP 8.89e14CEP n/a Swab: M0001964-100 Wand: M1000541 MA100034-02 Revision E (W) (P) / (C) EU Stamp ETD0000028 Bruker Optics DE-tector Flex P/N 1880000 Library B_EXFL_EXPL10 n/a Swab: Sample Collector (P/N 8702660-E) 2018-09-28 / Rev. 1.02 (P/N 1859473) (H) (P) EU Stamp ETD0000029 1st Detect TRACER 1000 00-10001-01; 00-10001-03; 00-10001-04 5.2.25 7.17.0.185 11.0 Swab: P/N #88-10002-03; P/N #88-10002-05; P/N #88-10002-06; P/N #88-10002-07 Revision 36, 3/20/2023 (H) (P) / (C) EU Stamp ETD0000030 1st Detect TRACER 1000 00-10001-01; 00-10001-03; 00-10001-04 5.2.31 7.17.0.185 11.0 Swab: P/N #88-10002-03; P/N #88-10002-05; P/N #88-10002-06; P/N #88-10002-07 Revision 36, 3/20/2023 (H) (P) EU Stamp ETD0000031 Nuctech TR2000DC Detector CIL4.0 Firmware C1.2.0 D18.9.26 (Library E11.C01.1903) (Library E11.C01.1910) (Library E11.C07.1910) n/a Swab type -04A, or type -05A. Optional Swab Baker Type-02E 19.03 (H) (P) / (C) EU Stamp ETD0000032 Bruker Optics DE-tector Flex P/N 1880000 B_EXFL_EXPL11 n/a Swab: sample collector (P/N 8702660-E) 2019-08-27/Rev. 1.03, P/N 1859473 (H) (P) EU Stamp ETD0000033 Bruker Optics DE-tector Flex P/N 1880000 B_EXFL_EXPL11 n/a Swab: sample collector (P/N 8702660-E) Wand: P/N 8702515 2019-08-27/Rev. 1.03, P/N 1859473 (W) (P) / (C) EU Stamp ETD0000034 Rapiscan ITEMISER DX P0007018-014-CEP 8.89e16CEP n/a Swab: M0001964-100 MA100034-02 Rev E (H) (P) / (C) EU Stamp ETD0000035 Rapiscan ITEMISER DX P0007018-014-CEP 8.89e16CEP n/a Swab: M0001964-100 Wand M1000541 MA100034-02 Rev E (W) (P) / (C) EU Stamp ETD0000036 Nuctech TR2000DC Detector CIL4.0 Firmware C1.2.0 D18.9.26 (Library E11.C01.1903) (Library E11.C01.1910) (Library E11.C07.1910) n/a Swab type -04A, or type -05A. Optional Swab Baker Type-02E 20.02 (H) (P) / (C) EU Stamp ETD0000037 Smiths Detection IONSCAN 600 4824000E-101 4824000E-101P ECAC E (24758-1) ECAC E (24758A-1) ECAC E (24758-2) ECAC E (24758A-2) ECAC E (24758-4) ECAC E (24758A-4) n/a Swab: P/N 6824768-01; P/N 1824019-A Sampling Wand (Optional): P/N 3824750-1; P/N 3824750-2; 6824005 (Operator Manual) 6824007 (Quick Start Guide) (H) / (W) (P) / (C) EU Stamp ETD0000038 Bruker Optics RoadRunner P/N 1860001 B_RR00_EXPL15 n/a Swab: Sample Collector M (P/N 1842394); Test Marker RR (P/N 1867612); Sampling Wand (P/N 8702515) 2020-10-14 / Rev. 1.01 P/N 1870101 (H) / (W) (P) / (C) EU Stamp ETD0000039 Rapiscan ITEMISER DX P00007018-014-CEP 8.89e18CEP n/a Swab: M0001964-100 Wand: M1000541 MA100034-02 rev E (H) / (W) (P) / (C) EU Stamp ETD0000040 Nuctech TR2000DC Detector CIL4.0 Firmware C1.2.0 D18.9.26 (Library E11.C01.2110) n/a Thumbprint Wand Swab type -04A, or type -05A. Optional Swab Baker Type-02E V21.07 (W) (P) / (C) EU Stamp ETD0000041 Nuctech TR2000DC Detector CIL4.0 Firmware C1.2.0 D18.9.26: (Library E11.C02.2206) (Library E11.C04.2206) (Library E11.C05.2206) n/a Thumbprint Wand Swab type -04A, or type -05A. Optional Swab Baker Type-02E V21.07 (H) / (W) (P) / (C) EU Stamp ETD0000043 Rapiscan ITEMISER 5X P0007018-018-CEP 5X-3.0.9-CEP n/a Swab: M0001964-100; Wand M1000541 D05259 (W) (P) / (C) EU Stamp ETD0000045 Nuctech TR3000DE Detector CIL4.1; Firmware D2.0.0 D18.9.26 (Library E11.C01.2308) n/a Thumbprint Wand; Swab Type-04A; Optional Swab Baker Type-02E V23.02 (H) / (W) (P) / (C) EU Stamp ETD0000046 Smiths Detection IONSCAN 600 4824000E-101; 4824000E-101P ECAC E (24758-4) n/a Swab: P/N 24757-1; Wand: P/N 26616-1 6824005-EN-F IONSCAN 600 Operators Manual 20200519 24926-5-Master Configuration Items List ECAC (H) / (W) (P) / (C) EU Stamp ETD0000047 Rapiscan ITEMISER 5X P0007018-018-CEP 5X-3.1.3-CEP n/a Swab: M0001964-100 D05259 (H) (P) / (C) EU Stamp ETD0000048 Rapiscan ITEMISER 5X P0007018-018-CEP 5X-3.1.4-CEP n/a Wand: M1000541; Swab: M0001964-100 D05259 (H) / (W) (P) / (C) EU Stamp ETD0000050 Rapiscan ITEMISER 5X P0007018-018-CEP 5X-3.1.5-CEP n/a Wand: M1000541; Swab: M0001964-100 D05259 (H) / (W) (P) / (C) EU Stamp ETD0000051 1st Detect Tracer 1000 00-10001-04 5.3.32; 5.3.25 11.0 Sampling Swab: P/N 88-10002-05; Sampling Swab P/N 88-10002-06 Revision 36, 3/20/2023 (H) (P) / (C) (G1) EU Stamp ETD0000052 Leidos QS-B220HT 10011465 25106; 25107 1.4.8. Sampling Swab: P/N 42200191 Sampling Wand: P/N 10011279; Sampling Wand: P/N 10011451 Quick Start Guide:42400049; User Manual: 42400048 (H) / (W) (P) / (C) (G1) EU Stamp ETD0000053 Rapiscan Itemiser 5X P0007018-018-CEP 5X-3.1.6-CEP n/a Swab: M0001964-100; Sampling Wand: M1000541 D07165 (H) / (W) (P) / (C) (G1) EU Stamp ETD0000054 Rapiscan ITEMISER 4DX P0007018-015-CEP 4DX-30-CEP n/a Sampling Swab: M0002057; Sampling Wand: M0001240 MA100026-02 (H) / (W) (P) / (C) (G1) EU Stamp ETD0000055 Nuctech TR3000DE Detector CIL4.1; Firmware D2.0.0 D18.9.26 (Explosive library E11.C01.2308, Chemical library G01.E01.2501) n/a Swab-04A; Wand: Thumbprint Wand; Swab Baker-02E V23.02 (H) / (W) (P) / (C) (G1) EU Stamp ETD0000056 Nuctech TR2000DC Detector CIL4.0; Firmware C1.2.0 D18.9.26 (Explosive library E11.C04.2206, Chemical library G01.C01.2501) n/a Wand: Thumbprint Wand; Swab 04A V21.07 (H) / (W) (P) / (C) (G1) EU Stamp ETD0000057 Smiths Detection IONSCAN 600 4824000E-101; 4824000E-101-P 24758-5; 24758A-5 n/a Swab: P/N 1824019-A (multipack P/N 24757-1); Wand: P/N 26616-1; P/N 3824750-1; P/N 3824750-2 Operator Manual 6824005; Quick Start Guide: 6824007 (H) / (W) (P) / (C) (G1) EU Stamp ETD0000058 Smiths Detection IONSCAN 600 4824000E-101; 4824000E-101-P 24758-6 n/a Swab: P/N 40393-1 (multipack P/N 40391-1) Operator Manual 6824005; Quick Start Guide: 6824007 (H) (C) EU Stamp ETD0000059 Smiths Detection IONSCAN 600 4824000E-101 4824000E-101P ECAC E (24758-4); ECAC E (24758A-4) n/a Swab: P/N 1824019-A Wand: P/N 26616-1 6824005 (Operator Manual); 6824007 (Quick Start Guide) (W) (P) / (C) EU Stamp ETD0000060 Rapiscan ITEMISER 4DX P0007018-015-CEP 4DX-40-CEP n/a Sampling Swab: M0002057 MA100026-02 (H) (P) / (C) (G1) EU Stamp ETD0000061 Bruker Optics DE-tector flex P/N 1880000 Library B_EXFL_EXPL11_C08 n/a Swab: Sample Collector P/N8702660-E; Sampling Wand: P/N 8702515 Version 2026-01-30 /Rev. 1.05 (P/N 1859473) (H) / (W) (P) / (C) (G1) EU Stamp ETD0000062 1st Detect TRACER 1000 00-10001-04 5.3.32 11.0 Sampling wand: P/N 00-10008-01; Sampling Swab: P/N 88-10002-06 Revision 38 (W) (P) / (C) (G1) EU Stamp 7. LIQUID EXPLOSIVE DETECTION SYSTEM (LEDS) EQUIPMENT On the basis of the concept of operations provided by the manufacturer, the LEDS performance was tested for a given type of operations: — (A) means the LEDS screens individual containers and requires containers to be opened for sampling; — (B) means the LEDS screens individual containers with no requirement for containers to be opened; — (C) means the LEDS screens multiple containers with no requirement for containers to be opened. When type A, B or C equipment is used, LAG containers must be removed from cabin baggage and screened separately. — (D) means the LEDS screens LAG containers with no requirement for containers to be opened (original seal remains intact); — (D+) means the LEDS is additionally capable to screen LAG containers with complex electronics (e.g. laptops) present in cabin baggage. When type D or D+ equipment is used, LAG containers do not need to be removed from cabin baggage. Unique identifier Manufacturer Designation Detailed configuration Standard Status Hardware Detection algorithm System software Auxiliary hardware Concept of operations LEDS000001 Kromek Identifier BLS-1003 n/a CMP_SOF_0800 Rev 4 n/a n/a MAL-OPS-0851 2 (B) EU Stamp LEDS000002 Nuctech LS1516BA DHV 1.0 AV 3.1.0.9 V1.2.026.140 n/a 2010-06-01 CONOPS-V1-C 2 (B) EU Stamp LEDS000003 Smiths Detection HI-SCAN 6040aTiX n/a 05-92-30 n/a n/a 95592934, 10/08/2010 2 (C) EU Stamp LEDS000004 Smiths Detection HI-SCAN 7555aTiX HI-SCAN 7555aTiX 91460001 05-93-30 n/a n/a 95592934, 10/08/2010 2 (C) EU Stamp LEDS000005 Veriteque USA, Inc SwabTek LETK Test strip batch 200710 n/a n/a n/a July 2010 2 (A) EU Stamp LEDS000006 Smiths Detection HI-SCAN 6040aTiX HI-SCAN 6040aTiX 91290001 06-31-07 n/a n/a 95592934, 10/08/2010 2 (C) EU Stamp LEDS000007 Smiths Detection HI-SCAN 6040aTiX HI-SCAN 6040aTiX 91290001 06-31-35 n/a n/a 95592934, 10/08/2010 2 (C) EU Stamp LEDS000008 Agilent Technologies Insight100 INS100-v1.0 INS100-27 Rev. 1.0, 1 Sep 2011 Insight.exe (2.0.0.1) Insight100.exe (2.2.1.0) Spectrograph: Q22244 CCD: DR-324B-FI INS100-26 Rev. 1.0, 7 Sep 2011 3 (B) EU Stamp LEDS000009 Agilent Technologies Insight100 INS100-v1.0 INS100-27 Rev. 1.1, 1 Oct 2011 Insight100.exe (2.1.0.0) Insight100.exe (2.2.1.0) Spectrograph: Q22244 CCD: DR-324B-FI INS100-26 Rev. 1.0, 7 Sep 2011 2 (B) EU Stamp LEDS000010 Optosecurity OptoScreener on Smiths 6040i Smiths 6040i 6.0 n/a OS-3000 D500-10001 2 (C) EU Stamp LEDS000011 Smiths Detection HI-SCAN 7555aTiX HI-SCAN 7555aTiX 91460001 06-41-38 n/a n/a 95592934, 20/09/2011 2 (C) EU Stamp LEDS000012 Reveal Imaging Technologies CT-800 CT-800 4.3.0.2 n/a n/a CT-800 User Guide (P/N 81032) 2 (D) EU Stamp LEDS000013 Emisens EMILI EMILI 2 Database 7.1 ECAC_Retest_Jan2012_v3.ini n/a n/a Emili2_ConOP_03; Rev. 2.0 July 2011 2 (B) EU Stamp LEDS000014 Emisens EMILI EMILI 2 Database 7.3 ECAC_Retest_Jan2012_v3.ini n/a n/a Emili2_ConOP_03; Rev. 2.0 July 2011 2 (B) EU Stamp LEDS000015 Gilardoni FEP ME 640 05141092 n/a 3AUE0217 OptoScreener OS3000 System 5.8; Software: 5.8.0.42386 5.8.6.53192 Acquisition module 6.0; Liquid detection module 6.3 37300500-005 2 (C) EU Stamp LEDS000016 Gilardoni FEP ME 640 AMX 05141082 n/a 3AUE0183 OptoScreener OS3000 System 5.8; Software: 5.8.0.42386 5.8.6.53192 Acquisition module 6.0; Liquid detection module 6.3 37300500-005 2 (C) EU Stamp LEDS000017 Rapiscan 620 DV 620DV 3.280 n/a Rapiscan Tray (P/N 42106376 92106913 rev 1 2 (C) EU Stamp LEDS000018 Smiths Detection HI-SCAN 6040aTiX HI-SCAN 6040aTiX 91290001 06-60-30 n/a Schoeller Allibert tray 2A021 95593780, 30/03/2012 2 (C) EU Stamp LEDS000019 Battelle LS10 LS10 (635109J5000-10) v1.3.14.1026 n/a Firmware v1.24 LS10 Operator Manual (635109J0040) 2 (B) EU Stamp LEDS000020 Battelle LS10 LS10 (635109J5000-10) v1.3.20.1045 n/a Firmware v1.24 LS10 Operator Manual (635109J0040) 2 (B) EU Stamp LEDS000021 Analogic COBRA AN6980 Config 4.192 (261) n/a n/a 1-64812 2 (D) / (D+) EU Stamp LEDS000022 Analogic COBRA AN6980 Config 4.193 (261) n/a n/a 1-64812 2 (D) / (D+) EU Stamp LEDS000023 CEIA EMA-3 EMA-3 PV EMA3 3540, PVCT EMAO 2100 n/a n/a FI200K0015v1116UK 3 (B) EU Stamp LEDS000024 FLIR PaxPoint V2 n/a Beta 1.00 n/a n/a 20.08.2010 with one additional page concerning specific sampling for type A tests 3 (A) EU Stamp LEDS000025 Thermo Fisher Scientific TruScreen 580-1281 n/a V2.1.0/Build 9119/Conf BLSM-A1-T03E n/a n/a Brochure TSCBR02 with one additional page 3 (A) EU Stamp LEDS000026 Kromek Identifier BLS-1006 SPF-TEC-1207 7.4.0.0 n/a BOM-OPS-1006 CON-OPS-0866 Rev3 2 (B) EU Stamp LEDS000027 Smiths Detection HI-SCAN 6040i 91520001 06-82-37 n/a TIM (Threat Inquest Module) 95594060 2 (C) EU Stamp LEDS000028 Smiths Detection HI-SCAN 6046si 91150001 06-82-38 n/a TIM (Threat Inquest Module) 95594060 2 (C) EU Stamp LEDS000029 Smiths Detection HI-SCAN 7555aTiX HI-SCAN 7555aTiX 91460001 06-31-36 n/a n/a 95592934, 20/09/2011 2 (C) EU Stamp LEDS000030 Agilent Technologies Insight100 INS100-v1.0 Measurement Software: 1.9.0 n/a n/a INS100-25-EN Revision 2.5 3 (B) EU Stamp LEDS000031 FLIR FIDO X3C X3 (PNO.: FH-65-A) Measurement Software: Beta 1.00 Build 319 n/a n/a FIDO X3C Administrator Manual 1.00 Rev A (June 2013) 2 (A) EU Stamp LEDS000032 Kromek Identifier BLS-1006 SPF-TEC-1207 7.5.0.10 n/a BOM-OPS-1006 CON-OPS-0866 Rev3 3 (B) EU Stamp LEDS000033 Kromek Identifier BLS-1006 SPF-TEC-1207 7.5.0.9 n/a BOM-OPS-1006 CON-OPS-0866 Rev3 3 (B) EU Stamp LEDS000034 Kromek Identifier BLS-1006 SPF-TEC-1207 7.5.0.8 n/a BOM-OPS-1006 CON-OPS-0866 Rev3 2 (B) EU Stamp LEDS000035 Smiths Detection HI-SCAN 6040aTiX HI-SCAN 6040aTiX 91290001 06-60-32 n/a Schoeller Allibert tray 2A021 95593780, 30/03/2012 2 (C) EU Stamp LEDS000036 Agilent Technologies Insight100 INS100-v1.0 Measurement Software: 1.9.0 n/a n/a INS 100-25-EN Rev. 2.5 INS100-24-EN Rev. 1.1 3 (A) EU Stamp LEDS000037 Leidos ACX6.4-MV (3 view) with Optosecurity XMS® 1000-MVACX-03 REV:C0 V 6.7 n/a HP Z620 (OS-3000, 5.12) 8500-10118-00 REV:A1 2 (C) EU Stamp LEDS000038 Nuctech RT1003 3.0 1.0.9.6 n/a n/a 7.1.1 2 (B) EU Stamp LEDS000039 Optosecurity OptoScreener on Smiths 6040i Smiths 6040i V 6.0 n/a HP Z620 (OS3000 – 5.33) D500-10001 2 (C) EU Stamp LEDS000040 Optosecurity OptoScreener on Smiths 6040i Smiths 6040i V 6.0 n/a HP Z620 (OS3000 – 6.8.1) D500-10001 2 (C) EU Stamp LEDS000041 Optosecurity OptoScreener on Smiths 6046si Smiths 6046si V 6.5 n/a HP Z620 / OS3000 D500-10001 2 (C) EU Stamp LEDS000042 Smiths Detection HI-SCAN 6040aTiX HI-SCAN 6040aTiX 91290001 07-60-30 n/a Schoeller Allibert tray 2A021 95593780, 30/03/2012 2 (C) EU Stamp LEDS000043 Battelle LS10 LS10 (635109J5000-10) v1.3.32.1613 v1.3.40.1614 n/a Firmware v1.24 LS10 Operator Manual (635109J0040) 3 (B) EU Stamp LEDS000044 Emisens EMILI EMILI TS Measurement Software: ecac_std_v5.1.ini ecac_std_v5.2.ini ecac_std_v5.3.ini n/a n/a EMILI TS Conops 0513 2 (B) EU Stamp LEDS000045 Nuctech LS1516BA DHV 1.0 AV 3.2.1.11 AV 3.2.1.12 V1.2.036.188 n/a 2010-06-01 V1-C 3 (B) EU Stamp LEDS000046 Osaka University NuLEDS 1.0 Nu-1.0 Nu-1.0 n/a No tray Nu-1.0 2013-11-06 2 (B) EU Stamp LEDS000047 Smiths Detection HI-SCAN 6040-2is HR HI-SCAN 6040-2is HR 90140002 08-12-30 n/a n/a 95584650, 15/09/2013 2 (C) EU Stamp LEDS000048 Smiths Detection HI-SCAN 6040-2is HR HI-SCAN 6040-2is HR 90140002 08-12-35 n/a n/a 95584650, 15/09/2013 2 (C) EU Stamp LEDS000049 Smiths Detection HI-SCAN 6040aTiX HI-SCAN 6040aTiX 91290001 06-31-37 n/a Herbert Tray 91280AS 95594586, 22/11/2013 2 (C) EU Stamp LEDS000050 Smith’s Detection HI-SCAN 6040aTiX HI-SCAN 6040aTiX 91290001 06-31-37 n/a MacDonald Humfrey Tray 95594586, 22/11/2013 2 (C) EU Stamp LEDS000051 Smiths Detection HI-SCAN 7555aTiX HI-SCAN 7555aTiX 91460001 06-31-38 n/a Herbert Tray 91280AS 95594585, 22/11/2013 2 (C) EU Stamp LEDS000053 CEIA EMA-3 EMA-3 PV EMA3 3550, PVCT EMAO 2100, AL3 n/a n/a FI200K0015v1122 2 (B) EU Stamp LEDS000054 CEIA EMA-3 EMA-3 PVCT EMAO 2100, PVEX EMAX 5311 n/a EMA-EXTP-EXA-MS FI200K0015v1209 3 (A) EU Stamp LEDS000055 Nuctech RT1003 3.0 Measurement Software: 1.0.9.12 n/a n/a 7.1.1 3 (B) EU Stamp LEDS000056 Nuctech XT2080 X-Ray CT CH-II 1.2 LEDS 1.7 n/a n/a V1.1 2 (D) / (D+) EU Stamp LEDS000057 Gilardoni FEP ME 640 37493500-000 3AUE0263-002 3AUE0217 n/a 37493700-003 2 (C) EU Stamp LEDS000058 Gilardoni FEP ME 640 AMX 37548400-000 3AUE0263-002 3AUE0183-002 n/a 37548500-001 2 (C) EU Stamp LEDS000059 One Resonance Sensors MobiLab® BLS MobiLab® BLS Measurement Software: 2.01B YM BLS 1402 n/a n/a MobiLab®BLS-Configuration A, February 5th, 2014 2 (B) EU Stamp LEDS000060 Agilent Technologies Insight100 INS100-v1.0 Measurement Software: 1.9.0 Auxiliary Measurement Software: 1.2.0, Grav200.exe (1.0) Grav-kit-v1.0 INS100-35-EN Revision 1.0 3 (B) EU Stamp LEDS000061 Nuctech LS1516BA DHV 1.0 AV 3.2.2.0 AV 3.2.2.1 V1.2.036.200 n/a 2010-06-01 V1-C 3 (B) EU Stamp LEDS000062 Nuctech LS1516BA DHV 1.0 AV 3.2.2.0 AV 3.2.2.1 V1.2.036.200 n/a 2013-11-06 V2-B 2 (C) EU Stamp LEDS000063 CEIA EMA-3 EMA-3 PV EMA33550, PVCT EMAO 2100, AL4 n/a n/a FI200K0015v1122 3 (B) EU Stamp LEDS000064 Smiths Detection HI-SCAN 6040-2is HR HI-SCAN 6040-2is HR 90140002 08-13-30 n/a n/a 95584650, 15/09/2013 2 (C) EU Stamp LEDS000065 Smiths Detection HI-SCAN 6040-2is HR HI-SCAN 6040-2is HR 90140002 08-14-40 n/a n/a 95584650, 15/09/2013 3 (C) EU Stamp LEDS000066 Gilardoni FEP ME 640 37493500-000 3AUE0263-002 3AUE0217-001 n/a 37493700-003 2 (C) EU Stamp LEDS000067 Nuctech RT1003E 2.0 1.1.2 n/a n/a 3.1 3 (B) EU Stamp LEDS000068 Rapiscan 620 DV 620DV 3.280 n/a MacDonald Humfrey Tray (42112481) Herbert Tray (P/N 42112482) 92106913 rev 2 2 (C) EU Stamp LEDS000069 Smiths Detection HI-SCAN 6040aTiX HI-SCAN 6040aTiX 91290001 08-51-33 n/a CQRTS ST-14 Tray 95595576, 18/03/2015 2 (C) EU Stamp LEDS000070 Gilardoni FEP ME 640 37493500-001 3AUE0263-003 3AUE0217-001 n/a 37620800-001 2 (C) EU Stamp LEDS000071 Gilardoni FEP ME 640 AMX 37548400-001 3AUE0263-003 3AUE0183-002 n/a 37620900-001 2 (C) EU Stamp LEDS000072 Smiths Detection HI-SCAN 6040aTiX HI-SCAN 6040aTiX 91290001 08-51-33 n/a CQRTS ST-15 Tray 95595576, 18/03/2015 2 (C) EU Stamp LEDS000073 Emisens EMILI 3 EMILI 3 Measurement Software: ecac_std_v6.1.ini n/a n/a EMILI 3 Conops 1214 (Rev. 1 March 2015) 2 (B) EU Stamp LEDS000074 Emisens EMILI 3 EMILI 3 Measurement Software: ecac_std_v6.13.ini ecac_std_v6.14.ini n/a n/a EMILI 3 Conops 1214 (Rev. 1 March 2015) 3 (B) EU Stamp LEDS000075 Agilent Technologies Insight200M Cobalt P/N 071-T008-201 SORS Detection Software: SORS DLL Measurement software (1.9.0) Metal Detection Software: Gravi200.exe (1.0) Gravi200.exe (1.1) Gravi200.DLL (1.1) n/a n/a INS200M – 25 – EN Revision 1.1 3 (B) EU Stamp LEDS000076 Agilent Technologies Insight200M Cobalt P/N 071-T008-201 SORS Detection Software: SORS DLL Measurement software (1.9.0) Metal Detection Software: Gravi200.exe (1.0) n/a n/a INS200M – 24 – EN Revision 1.0 used with INS200M – 25 – EN Revision 1.1 3 (A) EU Stamp LEDS000077 Veriteque USA, Inc SwabTek LETK Test strip 082015V2 n/a n/a n/a LETK082015 v2.0 LETK072016 v3.0 2 (A) EU Stamp LEDS000078 Leidos ClearScan 1000-10001-CS Rev 01 EDS-1.1.1 n/a Scarabee Long Tray 8100-26903-00 2 (D) / (D+) EU Stamp LEDS000079 Leidos ClearScan 1000-10001-CS Rev 01 EDS-1.1.1 n/a Herbert Tray 8100-26903-00 2 (D) / (D+) EU Stamp LEDS000080 Battelle LS10 LS10 (635109J5000-10) v2.3.40.1705 n/a Firmware v1.24 LS10 Operator Manual (635109J0040) 3 (B) EU Stamp LEDS000081 Battelle LS10 LS10 (635109J5000-10) v2.2.14.001 n/a Firmware v1.24 LS10 Operator Manual (635109J0040) 2 (B) EU Stamp LEDS000082 Gilardoni FEP ME 640 AMX 37548400-001 3AUE0263-004 3AUE0183-002 Gilardoni Tray 10461200 37637700-001 rev 002 2 (C) EU Stamp LEDS000083 Kumahira Co. Ltd. LSR-M1 1.0 1.0 n/a No tray 2015/09/26 v1.0 2 (B) EU Stamp LEDS000084 Smiths Detection HI-SCAN 6040-2is HR HI-SCAN 6040-2is HR 90140002 09-12-30 n/a Herbert Tray 91280AS 95594585, 24/11/2015 2 (C) EU Stamp LEDS000085 Smiths Detection HI-SCAN 6040aTiX HI-SCAN 6040aTiX 91290001 08-90-30 n/a Schoeller Allibert tray 2A021 95593780, 30/03/2012 2 (C) EU Stamp LEDS000086 Smiths Detection HI-SCAN 6040aTiX HI-SCAN 6040aTiX 91290001 08-90-31 09-12-23 n/a Schoeller Allibert tray 2A021 95593780, 30/03/2012 3 (C) EU Stamp LEDS000087 Nuctech RT1003EB 2.0 1.1.3 n/a n/a 2.1 3 (B) EU Stamp LEDS000088 Nuctech RT1003EB 2.0 1.1.3 n/a n/a 2.1 3 (A) EU Stamp LEDS000089 Smiths Detection HI-SCAN 7555aTiX HI-SCAN 7555aTiX 91460001 09-12-26 n/a Schoeller Allibert Tray 2A021 95593780, 30/03/2012 3 (C) EU Stamp LEDS000090 DetectaChem SEEKERe 2.5.1 13.1.0 n/a n/a SEEKERe User Manual (R1.10) 2 (A) EU Stamp LEDS000091 DetectaChem SEEKERe 2.5.1 13.2.2 n/a n/a SEEKERe User Manual (R1.10) 2 (A) EU Stamp LEDS000092 DetectaChem SEEKERe 2.5.1 13.3.0 n/a n/a SEEKERe User Manual (R1.10) 2 (A) EU Stamp LEDS000093 Kumahira Co. Ltd. LSR-M2 1.00 1.00 1.00 NIR.DB.ECAC.1.0.0.0 1.00 3 (B) EU Stamp LEDS000094 Smiths Detection HI-SCAN 6040-2is HR HI-SCAN 6040-2is HR 90140002 09-15-19 n/a Herbert Tray 91280AS (P/N 34460688) 95595885 (2016/09/26) 2 (C) EU Stamp LEDS000095 Smiths Detection HI-SCAN 6040-2is HR HI-SCAN 6040-2is HR 90140002 09-15-20 n/a Schoeller Allibert tray 2A021 (P/N 11112352) 95595885 (2016/09/26) 2 (C) EU Stamp LEDS000096 Smiths Detection HI-SCAN 6040-2is HR HI-SCAN 6040-2is HR 90140002 09-15-18 n/a Herbert Tray 91280AS (P/N 34460688) 95595885 (2016/09/26) 2 (C) EU Stamp LEDS000097 Smiths Detection HI-SCAN 6040aTiX 6040aTiX 08-90-31 n/a Schoeller Allibert tray 2A021 (P/N 11112352) 95595885 (2016/09/26) 3 (C) EU Stamp LEDS000098 Smiths Detection HI-SCAN 6040aTiX 6040aTiX 09-15-13 n/a Schoeller Allibert tray 2A021 (P/N 11112352) 95595885 (2016/09/26) 3 (C) EU Stamp LEDS000099 Smiths Detection HI-SCAN 6040aTiX 6040aTiX 09-16-23 n/a Herbert Tray 91280AS (P/N 34460688) 95595885 (2016/09/26) 3 (C) EU Stamp LEDS000100 Smiths Detection HI-SCAN 6040aTiX 6040aTiX 08-90-31 n/a Herbert Tray 91280AS (P/N 34460688) 95595885 (2016/09/26) 3 (C) EU Stamp LEDS000101 Smiths Detection HI-SCAN 6040aTiX 6040aTiX 09-15-13 n/a Herbert Tray 91280AS (P/N 34460688) 95594585 (22/11/2013) 3 (C) EU Stamp LEDS000102 Smiths Detection HI-SCAN 6040aTiX 6040aTiX 09-16-23 n/a Schoeller Allibert tray 2A021 (P/N 11112352) 95595885 (2016/09/26) 3 (C) EU Stamp LEDS000103 Smiths Detection HI-SCAN 7555aTiX HI-SCAN 7555aTiX 91460001 09-15-16 n/a Schoeller Allibert tray 2A021 (P/N 11112352) 95595885 (2016/09/26) 3 (C) EU Stamp LEDS000104 Smiths Detection HI-SCAN 7555aTiX HI-SCAN 7555aTiX 91460001 09-15-25 n/a Herbert tray 91280AS (P/N 34460688) 95595885 (2016/09/26) 3 (C) EU Stamp LEDS000105 Smiths Detection HI-SCAN 7555aTiX HI-SCAN 7555aTiX 91460001 09-15-25 n/a Schoeller Allibert tray 2A021 (P/N 11112352) 95595885 (2016/09/26) 3 (C) EU Stamp LEDS000106 Smiths Detection HI-SCAN 7555aTiX HI-SCAN 7555aTiX 91460001 09-16-26 n/a Schoeller Allibert tray 2A021 (P/N 11112352) 95595885 (2016/09/26) 3 (C) EU Stamp LEDS000107 Smiths Detection HI-SCAN 7555aTiX HI-SCAN 7555aTiX 91460001 09-17-16 n/a Herbert tray 91280AS (P/N 34460688) 95595885 (2016/09/26) 3 (C) EU Stamp LEDS000108 Smiths Detection HI-SCAN 7555aTiX HI-SCAN 7555aTiX 91460001 09-17-26 n/a Herbert tray 91280AS (P/N 34460688) 95595885 (2016/09/26) 3 (C) EU Stamp LEDS000109 Kumahira Co. Ltd. LSR-M2 1.01 1.00 1.01 NIR.DB.ECAC.1.0.0.0 CONOP v1.00 3 (B) EU Stamp LEDS000110 Nuctech RT1003EB 2.0 1.1.3 n/a n/a 2.2 3 (B) EU Stamp LEDS000111 Nuctech RT1003EB 2.0 1.1.3 n/a n/a 2.2 3 (A) EU Stamp LEDS000112 Smiths Detection HI-SCAN 6040-2is HR HI-SCAN 6040-2is HR 90140002 09-15-20 n/a Smiths Detection Tray (P/N 34486990) Smiths Detection tray 2 (P/N 34482148) 95595885 (2016/09/26) 2 (C) EU Stamp LEDS000113 Smiths Detection HI-SCAN 6040aTiX 6040aTiX 09-16-23 n/a Smiths Detection Tray (P/N 34486990) Smiths Detection tray 2 (P/N 34482148) 95595885 (2016/09/26) 3 (C) EU Stamp LEDS000114 Smiths Detection HI-SCAN 6040aTiX 6040aTiX 09-18-13 n/a MacDonald Humfrey Tray (P/N 34460689) 95595885 (2016/09/26) 3 (C) EU Stamp LEDS000115 Smiths Detection HI-SCAN 6040aTiX 6040aTiX 09-18-24 n/a MacDonald Humfrey Tray (P/N 34460689) 95595885 (2016/09/26) 3 (C) EU Stamp LEDS000116 Kumahira Co. Ltd. LSR-M2 1.01 1.00 1.02 NIR.DB.ECAC.1.0.0.0 CONOP v1.01 (24/04/2018) 3 (B) EU Stamp LEDS000117 Nuctech CX6040D CX6040D.B05N Lida V1.0.1 n/a LTray V1.0 CONOPS CX6040D V1.0 (2017-12-01) 2 (C) EU Stamp LEDS000118 Kumahira Co. Ltd. LSR-M2 1.01 1.00 1.03 NIR.DB.ECAC.1.0.0.0 CONOP v1.01 (24/04/2018) 3 (B) EU Stamp LEDS000120 Smiths Detection HI-SCAN 6040aTiX 6040aTiX 08-90-31 n/a Smiths Detection tray (P/N 34486990) Smiths Detection tray 2 (P/N 34482148) 95595885 (2016/09/26) 3 (C) EU Stamp LEDS000121 Smiths Detection HI-SCAN 6040-2is HR HI-SCAN 6040-2is HR 90140002 09-19-19 n/a Vanderlande tray (P/N P10128 / 095527-727) Vanderlande inlay (P/N P13715 / 095535-212) 95596016 (2017/09/26) 2 (C) EU Stamp LEDS000122 Smiths Detection HI-SCAN 6040aTiX 6040aTiX 09-15-13 n/a Smiths Detection tray (P/N 34486990) Smiths Detection tray 2 (P/N 34482148) 95595885 (2016/09/26) 3 (C) EU Stamp LEDS000123 Smiths Detection HI-SCAN 6040aTiX 6040aTiX 09-19-23 n/a Vanderlande Scannojet tray (P/N P10128 / 095527-727) 95595885 (2016/09/26) 3 (C) EU Stamp LEDS000124 Smiths Detection HI-SCAN 6040aTiX 6040aTiX 09-70-23 n/a Vanderlande Scannojet tray (P/N P10128 / 095527-727) 95596016 3 (C) EU Stamp LEDS000125 Kumahira Co. Ltd. LSR-M2 1.01 1.01 V 2.00 V 2.01 V 2.10 V 2.20 V 2.30 NIR. DB. ECAC 1.0.0.0 No tray v1.02 3 (B) EU Stamp LEDS000126 Kumahira Co. Ltd. LSR-M2 1.01 1.01 V 2.00 V 2.01 V 2.10 V 2.20 V 2.30 NIR. DB. ECAC 1.0.0.0 No tray v1.02 3 (A) EU Stamp LEDS000127 Smiths Detection HI-SCAN 7555aTiX HI-SCAN 7555aTiX 91460001 09-16-26 n/a Smiths Detection Tray (P/N 34486990) Smiths Detection tray 2 (P/N 34482148) 95596016 (2017/09/26) 2 (C) EU Stamp LEDS000128 X-Ray Center XRC 60-40DV n/a 108.1.117.187.21 n/a tray: Elder engineering (P/N 42106376) Foam (Polyformes, P/N 256412) Bolts (RS components, P/N 12234438) MCIL Rev.1 2 (C) EU Stamp LEDS000129 X-Ray Center XRC 60-40DV n/a 108.1.117.187.25 n/a tray: Elder engineering (P/N 42106376) Foam (Polyformes, P/N 256412) Bolts (RS components, P/N 12234438) MCIL Rev.1 2 (C) EU Stamp LEDS000130 X-Ray Center XRC 60-40DV n/a 108.1.117.187.35 n/a tray: Elder engineering (P/N 42106376) Foam (Polyformes, P/N 256412) Bolts (RS components, P/N 12234438) MCIL Rev.1 3 (C) EU Stamp LEDS000131 Veriteque USA, Inc SwabTek LETK Test strip batch BL 315250 n/a n/a n/a LTD 29 November 2018 v2.0 3 (A) EU Stamp LEDS000132 Nuctech CX 7555D CX7555D.A03N Lida V1.0.2 n/a Tray: LTray V1.0 CONOPS_CX7555D_LEDS_V 1.0_20190716 2 (C) EU Stamp LEDS000134 Rapiscan 620 DV n/a 3.500; 3.520 n/a Vanderlande Scannojet tray (P/N P10128 / 095527-727) 92106913, Rev 2 2 (C) EU Stamp LEDS000135 Agilent Technologies Insight200M Agilent G6913A with Cobalt internal P/N 071-T008-201 SORS Detection Software: SORS DLL Measurement software (1.9.0) Metal Detection Software: Gravi200.exe (1.0) Gravi200.exe (1.1) Gravi200.DLL (1.1) n/a n/a Type B PLRM-CUD22 Insight200M CONOPS Rev 2.0 3 (B) EU Stamp LEDS000136 Agilent Technologies Insight200M Agilent G6913A with Cobalt internal P/N 071-T008-201 SORS Detection Software: SORS DLL Measurement software (1.9.0) Metal Detection Software: Gravi200.exe (1.0) n/a n/a Type A PLRM-CUD21 Insight200M CONOPS Rev 2.0 3 (A) EU Stamp LEDS000137 Smiths Detection HI-SCAN 6040aTiX 6040aTiX 09-16-23 n/a Smiths Detection tray 3 (P/N 34495374, with Safety-Walk + RFID-Tag + Liquidinlay) 95596016 rev. 02 (2020/03/01) 2 (C) EU Stamp LEDS000138 Smiths Detection HI-SCAN 7555aTiX 7555aTiX 09-71-27 n/a Smiths Detection Tray (P/N 34486990) 95596016 (2017/09/26) 2 (C) EU Stamp LEDS000139 Smiths Detection HI-SCAN 6040-2is HR HI-SCAN 6040-2is HR 90140002 09-15-20 n/a Smiths Detection tray 3 (P/N 34495374, with Safety-Walk + RFID-Tag + Liquidinlay) 95596016 rev. 02 (2020/03/01) 3 (C) EU Stamp LEDS000140 CEIA EMA-4 EMA-4 ALG1 n/a n/a FI200K048v1000hUK 3 (B) EU Stamp LEDS000141 Smiths Detection HI-SCAN 6040 DV 6040 DV 30-00-18 n/a Smiths Detection tray 2 (P/N 34482148) Smiths Detection tray 3 (P/N 34495374, with Safety-Walk + RFID-Tag + Liquidinlay) 95596016 rev. 02 (2020/03/01) 2 (C) EU Stamp LEDS000142 Rapiscan 920DX 920DX 1.9 n/a Herbert tray (P/N 42112482) D05354 3 (C) EU Stamp LEDS000143 Rapiscan 920DX 920DX 2.01 n/a Vanderlande tray (P/N 095527-727) D05354 3 (C) EU Stamp LEDS000144 Rapiscan 920DX 920DX 2.02 n/a MacDonald Humfrey tray (P/N 101005244) D05354 3 (C) EU Stamp LEDS000145 Smiths Detection HI-SCAN 6040 DV 6040 DV 30-00-29 n/a Vanderlande Scannojet (P/N 10128 /095527-727) 95596016 rev. 02 (2020/03/01) 2 (C) EU Stamp LEDS000146 Veriteque USA, Inc SwabTek LETK LTD Gen 2 n/a n/a n/a LTD Gen 2 v1.1 3 (A) EU Stamp LEDS000147 Nuctech Kylin MV DHV 1.0 7.1.3 n/a Nuc680 Tray (P/N v3) Nuc680 Tray (P/N v5) EDSCB and LEDS V2.0 3 (C) EU Stamp LEDS000148 Nuctech CX6040D CX6040D.B07N Lida V1.0.4 n/a STL-Tray V1.0; L-Tray V1.0 CONOPS_CX6040D_V1.0_LEDS 2 (C) EU Stamp LEDS000149 Nuctech CX6040D CX6040D.B07N Lida V1.0.5 n/a STL-Tray V1.0; L-Tray V1.0 CONOPS_CX6040D_V1.0_LEDS 3 (C) EU Stamp LEDS000150 CEIA S.p.A EMA-4 EMA-4 ALG11; ALG12; ALG13 n/a n/a FI200K0048v1001hUK 3 (B) EU Stamp LEDS000151 Kumahira Co. Ltd. LSR-M3 1.00 1.00 n/a n/a ConOps_LSR-M3v1.01 2 (B) EU Stamp LEDS000152 Nuctech RT1003EB 3.0 2.0 n/a n/a RT1003EB CONOPS V3.0 3 (A) EU Stamp LEDS000153 Kumahira Co. Ltd. LSR-M2-CSE 1.01 1.11; 1.12 1.00 n/a LSR-M2-CSE Ver2.1 3 (B) EU Stamp LEDS000154 Kumahira Co. Ltd. LSR-M3 1.00; 1.10; 1.11; 1.12 1.01 n/a ConOps_LSR-M3v1.01 3 (B) EU Stamp LEDS000155 Leidos PX 640 37493500-001 3AUE0263-003 n/a n/a 37620800-001 2 (C) EU Stamp LEDS000156 Leidos PX 640 DV 37548400-001 3AUE0263-003 n/a n/a 37620900-001 2 (C) EU Stamp LEDS000157 Agilent Technologies Insight300M G6930A SORS: 1.1.0.25 Gravimetric: 1.0.0.13 Item Screenability:10.00.00 Model DB: 10.0.1 Metal DB: 10.02.00 Insight exe: 4.5.1870 Agilent Service: 1.9.0.8 n/a G6930-90002 A.01 3 (B) EU Stamp LEDS000158 Agilent Technologies Insight300M G6930A SORS: 1.1.0.25 Gravimetric: 1.0.0.13 Item Screenability:10.00.00 Model DB: 10.0.1 Metal DB: 10.02.00 Insight exe: 4.5.1870 Agilent Service: 1.9.0.8 Vial holder: G6923-52009 Vials: 5188-5392 G6930-90000 A.02 3 (A) EU Stamp 8. METHODS OF SCREENING USING NEW TECHNOLOGIES Left intentionally blank 9. EXPLOSIVE DETECTION DOGS Left intentionally blank 10. METAL DETECTION EQUIPMENT (MDE) Field of use: Cargo Unique identifier Manufacturer Designation Detailed configuration Standard Status Hardware Detection algorithm System software Auxiliary hardware Concept of operations MDE0000001 CEIA EMIS 8075 EMIS_8075_002 EMIS STD with configurations GOODS 1 and GOODS 2 SCD V5.800 ALM V5.720 n/a FI210K0010v1000 Yes EU Stamp MDE0000002 CEIA EMIS 130160 EMIS_130160_002 EMIS STD with configurations GOODS 1 and GOODS 2 SCD V5.800 ALM V5.720 n/a FI210K0008v1000 Yes EU Stamp MDE0000003 CEIA EMIS 130200 EMIS_130200_002 EMIS STD with configurations GOODS 1 and GOODS 2 SCD V5.800 ALM V5.720 n/a FI210K0008v1000 Yes EU Stamp 11. SECURITY SCANNERS On the basis of the concept of operations provided by the manufacturer, the security scanner performance was tested for a given type of operations: — (A) means a security scanner with automatic threat detection and indication of the location of detected objects on a stick figure. Unique identifier Manufacturer Designation Detailed configuration Standard Status Hardware Detection algorithm System software Auxiliary hardware Concept of operations SSC0000005 Smiths Detection eqo Configuration document Z7115020 Version 2.0 001-085 BI-01-08-F-000-00 n/a V1.7 2 (A) EU Stamp SSC0000006 Smiths Detection eqo Configuration document Z7115022 Version 1.0 001-082 BI-01-08-F-000-00 n/a V1.7 2.1 (A) EU Stamp SSC0000007 Smiths Detection eqo Configuration document Z7115023 Version 1.0 001-084 BI-01-08-F-000-00 n/a V1.7 2 (A) EU Stamp SSC0000009 Leidos ProVision 2 (PV-2) 1600-20982-00 E4.10.19 E4.15.19 SS2.1 n/a 8500-22184-00 2 (A) EU Stamp SSC0000011 Rohde & Schwarz R&S® QPS100 1.20 1.43 1.43 n/a 1.40 2 (A) EU Stamp SSC0000012 Rohde & Schwarz R&S® QPS200 2.10 2.12 2.12 n/a 2.10 2 (A) EU Stamp SSC0000015 Rohde & Schwarz R&S® QPS100 1.20 1.43 1.43.2 n/a 1.40 2 (A) EU Stamp SSC0000018 Rohde & Schwarz R&S® QPS200 2.10 2.12 2.12.2 n/a 2.10 2 (A) EU Stamp SSC0000024 Rohde & Schwarz R&S® QPS200 2.10 2.62 2.62 / 2.62 W n/a 2.10 2.1 (A) EU Stamp SSC0000027 Nuctech MW1000AA 1.0 2.1.0.5 2.1.0.177 n/a 1.6 2 (A) EU Stamp SSC0000029 Rohde & Schwarz R&S® QPS100 1.20 1.62 1.62 / 1.62 W n/a 1.40 2.1 (A) EU Stamp SSC0000031 Rohde & Schwarz R&S® QPS200 2.10 2.61 2.61 / 2.61 W n/a 2.10 2.1 (A) EU Stamp SSC0000037 Rohde & Schwarz R&S® QPS100 1.20 1.62 3.0.1 / 3.0.1 W n/a 1.40 2 (A) EU Stamp SSC0000039 Rohde & Schwarz R&S® QPS200 2.10 2.61 3.0.1 / 3.0.1 W n/a 2.10 2.1 (A) EU Stamp SSC0000040 Rohde & Schwarz R&S® QPS200 2.10 2.62 3.0.1 / 3.0.1 W n/a 2.10 2.1 (A) EU Stamp SSC0000042 Rohde & Schwarz R&S® QPS201 3.10 3.11 3.11 n/a 3.00 2.1 (A) EU Stamp SSC0000044 Rohde & Schwarz R&S® QPS201 3.30 3.31 3.31 n/a 3.00 2.1 (A) EU Stamp SSC0000045 Rohde & Schwarz R&S® QPS201 3.30 3.32 3.32 n/a 3.00 2.1 (A) EU Stamp SSC0000049 Rohde & Schwarz R&S® QPS100 1.20 1.62 3.0.2 / 3.0.2 W 3.1.1 / 3.1.1 W n/a 1.40 2.1 (A) EU Stamp SSC0000051 Rohde & Schwarz R&S® QPS200 2.10 2.61 3.0.2 / 3.0.2 W 3.1.1 / 3.1.1 W n/a 2.10 2.1 (A) EU Stamp SSC0000052 Rohde & Schwarz R&S® QPS200 2.10 2.62 3.0.2 / 3.0.2 W 3.1.1 / 3.1.1 W n/a 2.10 2.1 (A) EU Stamp SSC0000054 Rohde & Schwarz R&S® QPS201 3.30 3.32 3.0.2 / 3.0.2 W 3.1.1 / 3.1.1 W n/a 3.00 2.1 (A) EU Stamp SSC0000055 Leidos ProVision 2 (PV-2) 1600-20982-00 E4.55.50 SS5.1.43 SS8.1.50 SS8.3.40 n/a 8500-22184-00 2 (A) EU Stamp SSC0000059 Rohde & Schwarz R&S® QPS201 3.30 3.36 3.36 3.1.1 / 3.1.1 W n/a 3.00 2.1 (A) EU Stamp SSC0000066 Smiths Detection eqo 11129800 91470001 001-112 BI-01-09-H-000-00 BI-01-09-H-245-00 BI-01-09-L-000-03 BI-01-09-G-000-05 n/a V1.7 2.1 (A) EU Stamp SSC0000068 Rohde & Schwarz R&S® QPS201 3.30 3.40 3.40 n/a 3.00 2.1 (A) EU Stamp SSC0000069 Rohde & Schwarz R&S® QPS201 3.30 3.42 3.42 n/a 3.00 2.1 (A) EU Stamp SSC0000070 Rohde & Schwarz R&S® QPS201 3.30 3.44 3.44 3.1.1 / 3.1.1 W n/a 3.00 2.1 (A) EU Stamp SSC0000072 Leidos ProVision 2 (PV-2) 1600-20982-00 E4.90.50 SS5.1.43 SS8.1.50 SS8.3.40 n/a 8500-22184-00 Rev. A0 2 (A) EU Stamp SSC0000073 Leidos ProVision 2 (PV-2) 1600-20982-00 E4.95.50 SS5.1.43 SS8.1.50 SS8.3.40 n/a 8500-22184-00 Rev. A0 2 (A) EU Stamp SSC0000075 Nuctech MW1000AA 1.0 3.7.1 2.1.3 4.1.2 5.0.1 n/a 1.10 (Nov 2018 & Aug 2021) 1.11 (Jan 2018 & Aug 2021) 1.12 2.1 (A) EU Stamp SSC0000076 Leidos ProVision 2 (PV-2) 1600-20982-00 E4.108.50 SS5.1.43 SS8.1.50 SS8.3.40 n/a 8500-22184-00 Rev. A0 2.1 (A) EU Stamp SSC0000077 Leidos ProVision 2 (PV-2) 1600-20982-00 E4.110.50 SS5.1.43 SS8.1.50 SS8.3.40 n/a 8500-22184-00 Rev. A0 2.1 (A) EU Stamp SSC0000079 Rohde & Schwarz R&S® QPS201 3.50 3.60 3.60 W 3.1.1 / 3.1.1 W n/a 1178.5450.02-03.00 2.1 (A) EU Stamp SSC0000081 Rohde & Schwarz R&S® QPS201 3.50 3.62 3.62 n/a 1178.5450.02-03.00 2.1 (A) EU Stamp SSC0000082 Rohde & Schwarz R&S® QPS201 3.50 3.64 3.64 3.1.1 / 3.1.1 W n/a 1178.5450.02-03.00 2.1 (A) EU Stamp SSC0000083 CEIA JANUS 1.001 DS.1006 JUI.1005 n/a FT060K0171v1010 2.1 (A) EU Stamp SSC0000084 Rohde & Schwarz R&S®QPS201 3.30 3.62 3.62 n/a 1178.5450.02-03.00 2.1 (A) EU Stamp SSC0000085 Rohde & Schwarz R&S®QPS201 3.30 3.64 3.64 n/a 1178.5450.02-03.00 2.1 (A) EU Stamp SSC0000086 Rohde & Schwarz R&S®QPS201 3.50 3.65 3.64 3.1.1 / 3.1.1 W n/a 1178.5450.02-03.00 2.1 (A) EU Stamp SSC0000087 Rohde & Schwarz QPS 201 3.50 3.42 3.64 n/a 1178.5450.02-03.00 2.1 (A) EU Stamp SSC0000088 Leidos Provision 3 (PV-3) AX1000-1004-PV E10.10.50 SS10.1.0 n/a 8500-34794-00 Rev A0 2.1 (A) EU Stamp SSC0000089 CEIA JANUS 1.001 C1DA.1008 JUI.1005 n/a FT060K0170v1020 2.1 (A) EU Stamp SSC0000090 Leidos Provision 3 (PV-3) AX1000-1004-PV E10.20.50; E10.30.50 SS10.1.0 n/a 8500-34794-00 Rev A0 2.1 (A) EU Stamp SSC0000091 Nuctech MW2000AA 1.0 2.0.2 1.0.5 n/a 1.0 2.1 (A) EU Stamp SSC0000092 Shenmutek ES7; ES7-S 1.0 2.0.2 1.0.5 n/a 1.0 2.1 (A) EU Stamp SSC0000093 Rohde & Schwarz R&S®QPS201 3.30 3.74 3.64 n/a 1178.5450.02-03.00 2.1 (A) EU Stamp SSC0000094 Rohde & Schwarz R&S®QPS201 3.50 3.74 3.64 n/a 1178.5450.02-03.00 2.1 (A) EU Stamp SSC0000095 CEIA JANUS 1.001 C2DA.1008 C2DA.1009 C2DA.1010 JUI.1005 n/a FT060k0171v1030 2.1 (A) EU Stamp SSC0000096 Rohde & Schwarz R&SQPS201 3.30 3.76 3.64 n/a 1178.5450.02-03.00 2.1 (A) EU Stamp SSC0000097 Rohde & Schwarz R&SQPS201 3.50 3.76 3.64 n/a 1178.5450.02-03.00 2.1 (A) EU Stamp SSC0000098 CEIA S.p.A JANUS 1.001 C2DA.1011.0001 JUI.1006 n/a FT060K0171v1040 2.1 (A) EU Stamp SSC0000099 Leidos ProVision 2 (PV-2) 1600-20982-00 E4.130.50 SS8.1.50 SS8.3.40 n/a 8500-22184-00 2.1 (A) EU Stamp SSC0000100 Leidos Provision 3 (PV-3) 1000-10005-PV E10.40.50 SS20.1.0 PV3 n/a 8500-34794-00 Rev. A1 2.1 (A) EU Stamp SSC0000101 CEIA S.p.A JANUS 1.001 C2DA.1011.0002; C2DA.1011.0003 JUI.1006 n/a FT060K0171v1040 2.1 (A) EU Stamp SSC0000102 Rohde & Schwarz QPS Walk2000 4.10 3.29.3 3.18 n/a 1179.0445.02 – 04 2.1 (A) EU Stamp SSC0000103 Nuctech MW2000AA 1.0 2.1.2 1.0.5 n/a 1.0 2.1 (A) EU Stamp SSC0000104 Nuctech MW2000AA 1.0 2.1.3 1.0.5 n/a 1.0 2.1 (A) EU Stamp SSC0000105 Shenmutek ES7; ES7-S 1.0 2.1.2 1.0.5 n/a 1.0 2.1 (A) EU Stamp SSC0000106 Shenmutek ES7; ES7-S 1.0 2.1.3 1.0.5 n/a 1.0 2.1 (A) EU Stamp SSC0000107 CEIA JANUS 1.001 C1DA.1011.0001; C1DA.1011.0002; C1DA.1011.0003 JUI.1006 n/a FT060K0170v1040 2.1 (A) EU Stamp SSC0000108 Rohde & Schwarz R&S®QPS201 3.70 5.74 3.65 n/a 1178.5450.02–04.00 2.1 (A) EU Stamp SSC0000109 Rohde & Schwarz QPS Walk2000 (P2) 5.10 3.86.5 – Option A; 3.86.5 – Option B; 3.86.8 – Default 3.2 n/a 1179.7885.02-01 2.1 (A) EU Stamp SSC0000110 HANGZHOU RAYIN TECHNOLOGY ISD- SMW1701S- C/PS V1.0 2.0.2 V2.1 n/a 1.0 2.1 (A) EU Stamp 12. SHOE SCANNER EQUIPMENT 12.1 Shoe Metal Detection (SMD) equipment No entry. 12.2 Shoe Explosive Detection (SED) equipment No entry. 13. AUTOMATED PROHIBITED ITEMS DETECTION (APID) SOFTWARE The “ Manufacturer” column refers to the original developer of the APID detection software. Where the developer of the software differs from the equipment manufacturer, the latter is indicated as OEM (Original Equipment Manufacturer). Unique identifier Manufacturer Designation Detailed configuration Standard Status Hardware Detection algorithm System software Auxiliary hardware Concept of operations APID000001 SeeTrue (OEM: Analogic/ Rapiscan) ConneCT/ 920CT ConneCT; 920CT SeeTrue APIDS 41.11.0 n/a Vanderlande tray (P/N 095527-727) Leidos/MacDonald Humfrey tray (P/N 12043-SLT); Rapiscan/Herbert tray (P/N 101019470) Rapiscan 920CT – APIDS Test ConOps V1.1 Jan 17 2023 1 EU Stamp APID000002 Smiths Detection HI-SCAN 6040 CTiX 6040 CTiX; 6040 CTiX Model S 20-72-11 n/a Smiths Detection tray 2 (P/N 34482148); Smiths Detection tray 2 (P/N 34506084); Smiths Detection tray 3 (P/N 34496512); Smiths Detection tray 3 (P/N 34493797); Smiths Detection tray 3 (P/N 34495373); MacDonald Humfrey tray (P/N 34460689) 95596016 1 EU Stamp APID000003 Smiths Detection HI-SCAN 6040 CTiX 6040 CTiX; 6040 CTiX Model S 20-78-41 n/a Smiths Detection tray 2 (P/N 34482148); Smiths Detection tray 2 (P/N 34506084); Smiths Detection tray 3 (P/N 34496512); Smiths Detection tray 3 (P/N 34493797); Smiths Detection tray 3 (P/N 34495373); MacDonald Humfrey tray (P/N 34460689) 95596016 1 EU Stamp 14. EXPLOSIVE VAPOUR DETECTION (EVD) equipment No entry. ELI: http://data.europa.eu/eli/dec/2026/2404/oj ISSN 1977-0677 (electronic edition)

Related documents

Record · ID 1533138 · SHA-256 0272b17c5585bc52
Retrieved via Conceptio: every document is proof-bundled with source, license, and retrieval metadata.
Bring this data into your agent: Connect via MCP or API · 20 free credits to start · no card required
Read the Docs → · View CLI source on GitHub · Conceptio Open Knowledge Archive