Patient-specific breath-hold reproducibility in thoracic and abdominal radiotherapy: comparison of auditory and visual biofeedback.
Analyze & explore related research in Conceptio
Connect this record directly into your research workflow or AI agent. Explore citations across open repositories, query full text, and export structured proof bundles.
Patient-specific breath-hold reproducibility in thoracic and abdominal radiotherapy: comparison of auditory and visual biofeedback - PMC Skip to main content An official website of the United States government Here's how you know Here's how you know Search Log in Primary site navigation Search Log in Search PMC Full-Text Archive Search in PMC Journal List User Guide As a library, NLM provides access to scientific literature. Inclusion in an NLM database does not imply endorsement of, or agreement with, the contents by NLM or the National Institutes of Health. Learn more: PMC Disclaimer | PMC Copyright Notice Jpn J Radiol . 2026 Feb 25;44(6):1125–1133. doi: 10.1007/s11604-026-01948-0 Patient-specific breath-hold reproducibility in thoracic and abdominal radiotherapy: comparison of auditory and visual biofeedback Masahide Saito 1, ✉ , Naoki Sano 1 , Ryota Tozuka 1 , Hikaru Nemoto 1 , Koji Ueda 1 , Takafumi Komiyama 1 , Kan Marino 1 , Hiroshi Onishi 1 Author information Article notes Copyright and License information 1 Department of Therapeutic Radiology, University of Yamanashi, 1110 Shimokato, Chuo, Yamanashi 409-3898 Japan ✉ Corresponding author. Received 2025 Sep 15; Accepted 2026 Jan 4; Issue date 2026. © The Author(s) 2026 Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ . PMC Copyright notice PMCID: PMC13222199 PMID: 41739291 Abstract Background and purpose This study aimed to compare patient-specific reproducibility and comfort of breath-holding using auditory and visual biofeedback guidance in a respiratory monitoring system. Materials and methods A respiratory monitoring device that tracks abdominal and chest wall motion was used to provide auditory and visual feedback. Forty patients with thoracic or abdominal tumors underwent three computed tomography scans under each guidance method. Breath-hold reproducibility was assessed by measuring the distance between an anatomical landmark and the tumor. Patient preferences for the guidance method were also recorded. Results Both guidance methods demonstrated good breath-hold reproducibility. The mean displacement of the landmark-tumor distance was 1.26 ± 0.82 mm with visual guidance and 1.32 ± 0.72 mm with auditory guidance, with no statistically significant difference. No correlation was found between the two methods in individual patients. While 22 patients preferred visual guidance, 12 preferred auditory guidance, and 6 had no preference, the preferred method did not always correspond to improved reproducibility. Conclusion Regarding the reproducibility of breath-holding, both auditory and visual guidance methods demonstrated high precision. However, no significant differences were observed between the two approaches, and patient preference did not appear to affect reproducibility. Keywords: Respiratory motion management, Audio-visual feedback, Breath-hold, Reproducibility Introduction In radiotherapy, precise management of each respiratory motion reduces the internal target volume and improves the therapeutic efficacy for abdominal and thoracic organs influenced by respiratory motion. Implementing this technique to reduce the internal target volume results in a smaller radiation field and decreased exposure to surrounding normal tissues. Consequently, this may lead to a reduction in treatment-related adverse events and potentially allow for dose intensification without compromising tumor control [ 1 , 2 ]. Several respiratory control techniques have been developed, including breath-holding [ 3 , 4 ], respiratory gating [ 5 – 7 ], and beam tracking [ 8 , 9 ]. Although breath-holding requires individualized patient training and specialized equipment, it remains a widely adopted technique [ 10 , 11 ]. Deep inspiration breath-hold (DIBH) has gained attention in recent years for its potential to reduce cardiac radiation dose during left breast cancer irradiation [ 12 ]. Breath-hold irradiation, while effective in mitigating the impact of respiratory motion during radiotherapy, places a considerable burden on clinical staff due to the additional time required for patient coaching, repeated verification of breath-hold reproducibility, and potential workflow disruption [ 13 ]. Notably, a subset of patients demonstrates difficulty maintaining consistent breath-hold levels under visual guidance alone, thereby compromising treatment precision. To overcome these limitations, our group previously developed a simplified respiratory monitoring system (Abches, APEX Medical Inc., Tokyo, Japan), which utilizes dual-point motion detection on the chest and abdominal walls [ 14 ]. This system allows patients to regulate their respiratory phase autonomously using either visual or auditory biofeedback during computed tomography (CT) simulation and treatment sessions. In an earlier pilot study [ 15 ], we introduced an auditory-guided version of the system (Audio-Abches) and conducted a preliminary comparison between visual and auditory biofeedback modalities. However, that study was limited by a small sample size and possible confounding effects due to the fixed intervention sequence (e.g., auditory always followed by visual), which may have introduced learning or fatigue biases. Accordingly, the present study was undertaken to address these methodological limitations and to conduct a more comprehensive evaluation of breath-hold reproducibility and patient comfort under both visual and auditory biofeedback guidance using the updated Abches system. Methods and materials Study design This study was approved by the institutional review board of the University of Yamanashi (approval number: 2969). Forty patients with thoracic or abdominal tumors participated. Each patient underwent three CT scans using both guidance methods. To assess breath-hold reproducibility, the distance between an anatomical landmark and the tumor position was measured. Additionally, patients were asked which guidance method they preferred for comfortable breath-holding. Patient characteristics are summarized in Table 1 . Table 1. Patient characteristics Characteristic Group A (Visual ⇒ Audio) Group B (Audio ⇒ Visual) N 20 20 Age [median (range)] 67 (54–85) 74 (65–88) Sex [male/female] 13/7 17/3 Treatment site (Inhalation) Lung: 10 (8 upper; 2 lower) Lung: 18 (3 upper; 6 middle; 11 lower) Treatment site (Exhalation) Liver: 3 Pancreas: 3 Lymph node: 3 Kidney: 1 Lymph node: 2 Performance status [median (range)] 90 (80–100) 90 (80–100) Open in a new tab As illustrated in Fig. 1 , this retrospective study included 40 patients who underwent breath-hold irradiation. The patients were divided into two cohorts according to the treatment period and the sequence of feedback modalities. Group A consisted of 20 consecutive patients treated in 2009, and Group B consisted of 20 consecutive patients treated in 2022. In Group A, patients first received breath-hold training using visual feedback, followed by CT image acquisition under the same visual feedback conditions. Subsequently, the same patients underwent breath-hold training with audio feedback, and a second CT scan was obtained using audio feedback guidance. In contrast, Group B followed the reverse order: patients initially received BH training with audio feedback and underwent CT acquisition under audio feedback conditions, after which breath-hold training and CT acquisition were repeated using visual feedback guidance. Thus, all 40 patients underwent CT simulations under both feedback modalities, enabling intra-patient comparison of visual versus audio feedback. Fig. 1. Open in a new tab Flowchart of this study. Forty patients underwent breath-hold CT with both visual and audio feedback in different sequences to compare guidance It should be noted that the two groups differed in both the study period and technical environment. Group A patients were treated in 2009 using an early-generation breath-hold monitoring system, whereas Group B patients were treated in 2022 with an upgraded system and refined protocols. Therefore, potential differences in imaging resolution, system performance, and operator experience were anticipated. To account for these temporal and technical variations, comparative analyses were performed within each group (visual vs. audio feedback) and between groups (Group A vs. Group B) to evaluate the reproducibility and accuracy of breath-hold guidance and to assess the impact of system evolution over the 13-year interval. Details of auditory and visual feedback system The Abches system is a self-respiratory control device that utilizes visual cues for guidance. It consists of a main unit, an indicator panel, and two fulcrums placed on the patient’s chest or abdomen (shown in Fig. 2 ). A pointer connected to the indicator panel moves in tandem with the fulcrums during respiration. In visual feedback mode, a mirror positioned near the patient’s head allows them to observe their respiratory motion (bottom left image of Fig. 2 ). On the other hand, in audio feedback mode, the Abches device is connected to a PC and speakers via a LAN cable, and the respiratory waveform is processed to provide auditory guidance through three distinct sound levels (bottom right image of Fig. 2 ). The waveform is segmented into three amplitude-based regions, each associated with a specific cue: S L (sound emitted when below the breath-holding range), S B (within the breath-holding range), and S H (above the breath-holding range). These sounds had different pitches (SL: slow pitch, SB: fast pitch, SH: a constant high-pitched sound), allowing patients to recognize them intuitively. Further information on the device is provided in previous reports, including its applications in DIBH for left-sided breast cancer and respiratory gating techniques with conventional linac system for chest and abdominal organs [ 14 , 16 , 17 ]. When adapting to these technologies, after performing patient setup as described above, connect the Abches device to the LAN cable and manage the respiratory waveform on the PC. Fig. 2. Open in a new tab Appearance of the Abches system (top image). Respiratory signals—i.e., movements of the abdomen and chest—are detected via two mechanical fulcrums. The system supports two feedback modes: (1) visual feedback and (2) auditory feedback. In mode (1), the patient uses a mirror to visually monitor the indicator value and align their breathing accordingly (bottom left image). In mode (2), the Abches device is connected to a PC and speakers via a LAN cable, and the respiratory waveform is processed to provide auditory guidance through three distinct sound levels (bottom right image). The waveform is segmented into three amplitude-based regions, each associated with a specific cue: S L (sound emitted when below the breath-holding range), S B (within the breath-holding range), and S H (above the breath-holding range) Imaging and evaluation CT scanning for Group A was performed using the HiSpeed DXi (GE Medical Systems, Milwaukee, WI, USA) with a 2 mm slice thickness and the following parameters: 120 kV, 200 mA, 1 s per helical rotation, a pitch of 1.5, and a 38 cm field of view covering the entire thorax or abdomen (512 × 512 pixels). Group B was scanned under the same conditions using the Aquilion LB (Canon Medical Systems, Japan). The average scan time was approximately 10–15 s per scan, with each patient required to hold their breath only once during CT acquisition. The reproducibility of breath-holding under audio and visual guidance was assessed by measuring the distance from an anatomical landmark to the tumor across three repeated CT images for each method. Figure 3 shows three repeated CT scans of a representative case. The magnitude of displacement in each dimension (lateral, vertical, and longitudinal) as well as the three-dimensional vector were evaluated. After CT acquisition, patients were asked to indicate their preferred guidance method (i.e., visual or audio) for comfortable breath-holding. This survey employed a three-choice format, requiring participants to select one of the following options: auditory preference, visual preference, or either is acceptable. The correlation between the two guidance methods was also analyzed. Fig. 3. Open in a new tab Three repeated CT images of a typical case are shown. From left to right, axial, sagittal, and coronal views are presented. In the axial view, the red arrow indicates the distance from an anatomical landmark to the tumor, while in the sagittal and coronal views, the red point denotes the same anatomical landmark relative to the tumor For statistical analysis, the normality of each dataset was assessed using the Shapiro–Wilk test. If the data followed a normal distribution, the Student’s t-test was applied; otherwise, the Wilcoxon test was used. Consequently, comparisons between the Audio and Visual groups were conducted using the Wilcoxon test, whereas comparisons between Group A and Group B were analyzed using the Student’s t-test. In addition, comparisons among the three groups based on patient preference (Audio, Visual, or Either) were performed using the Kruskal–Wallis test. A significance level of α = 0.05 was adopted for all statistical tests. All statistical analyses were conducted using JMP Pro version 18 (SAS Institute, Cary, NC, USA). Results Figure 4 presents the breath-hold reproducibility in each direction and the 3D vector for all 40 patients, with Group A shown in blue and Group B in orange. Correlation coefficients were also calculated (Group A: blue text, Group B: orange text, all patients: black text), revealing no correlation between audio and visual guidance (R 2 < 0.1). Table 2 summarizes the mean and range of breath-hold reproducibility for both guidance methods and the results of intergroup comparisons using the Wilcoxon test. For visual guidance, the median [IQR] deviations were 0.54 [0.35–0.79] mm vertically, 0.46 [0.21–0.73] mm laterally, and 0.94 [0.00–0.94] mm longitudinally, with a 3D vector deviation of 1.13 [0.60–1.77] mm. For audio guidance, the corresponding median [IQR] values were 0.48 [0.35–0.79] mm, 0.44 [0.33–0.70] mm, 0.94 [0.00–0.94] mm, and 1.13 [0.60–1.77] mm, respectively. Overall, both methods demonstrated high reproducibility, with average deviations less than 1 mm in each direction and less than 1.5 mm in the 3D vector. The range of variations was comparable between the two methods, and no statistically significant differences were observed in any direction or in the 3D vector (p > 0.05). In addition, although the Kruskal–Wallis test showed no significant differences among the patient-preference subgroups, a modest trend was observed in which the visual-preference group tended to show slightly smaller median deviations than the audio-preference group across most axes. Fig. 4. Open in a new tab Breath-hold reproducibility in each direction (lateral, vertical, longitudinal) and the 3D vector for all 40 patients. Group A and Group B are represented in blue and orange, respectively. Correlation coefficients are indicated by colored text: blue for Group A, orange for Group B, and black for all patients Table 2. Comparison of breath-hold reproducibility between visual and audio feedback using Kruskal–Wallis test and Wilcoxon-test Visual feedback P-value† Audio feedback P-value* (Visual vs. Audio feedback) Patient preference Patient preference All (n = 40) Visual (n = 22) Audio (n = 12) Either (n = 6) All (n = 40) Visual (n = 22) Audio (n = 12) Either (n = 6) P-value† Vertical [mm] Mean ± SD 0.61 ± 0.39 0.67 ± 0.39 0.58 ± 0.42 0.44 ± 0.19 0.2791 0.61 ± 0.46 0.58 ± 0.52 0.59 ± 0.31 0.75 ± 0.47 0.5064 0.9317 Median [IQR] 0.54[0.35–0.79] 0.54[0.41–0.84] 0.57[0.22–0.85] 0.45[0.36–0.55] – 0.48[0.35–0.79] 0.46[0.30–0.76] 0.54[0.40–0.73] 0.60[0.52–0.85] – – Lateral [mm] Mean ± SD 0.55 ± 0.53 0.60 ± 0.65 0.52 ± 0.37 0.41 ± 0.20 0.6037 0.53 ± 0.50 0.56 ± 0.64 0.50 ± 0.23 0.50 ± 0.24 0.8710 0.5654 Median [IQR] 0.46[0.21–0.73] 0.46[0.24–0.69] 0.56[0.26–0.80] 0.40[0.23–0.54] – 0.44[0.33–0.70] 0.44[0.31–0.65] 0.50[0.35–0.70] 0.35[0.33–0.63] – – Longitudinal[mm] Mean ± SD 0.73 ± 0.78 0.68 ± 0.85 0.67 ± 0.78 1.06 ± 0.26 0.2382 0.75 ± 0.75 0.74 ± 0.68 1.00 ± 0.88 0.31 ± 0.44 0.1765 0.9465 Median [IQR] 0.94[0.00–0.94] 0.0[0.00–0.94] 0.24[0.00–1.18] 0.94[0.94–0.94] – 0.94[0.00–0.94] 0.94[0.00–0.94] 0.94[0.00–1.70] 0.00[0.00–0.71] – – 3D vector [mm] Mean ± SD 1.32 ± 0.72 1.40 ± 0.78 1.21 ± 0.72 1.25 ± 0.23 0.8980 1.26 ± 0.82 1.24 ± 0.89 1.37 ± 0.80 1.10 ± 0.43 0.6962 0.5257 Median [IQR] 1.13[0.60–1.77] 1.14[0.89–1.94] 1.19[0.72–1.57] 1.20[1.14–1.29] – 1.13[0.60–1.77] 1.08[0.49–1.82] 1.22[0.76–2.02] 1.06[0.71–1.43] – – Open in a new tab † , p-values by using Kruskal–Wallis test between 3 groups of patient preference, *: p-values by using Wilcoxon test between 2 groups of all patients for visual and audio feedback Table 3 presents the comparison between Group A and Group B, conducted using the Student’s t-test with 95% confidence intervals. For visual guidance, Group B tended to show smaller deviations in all directions compared with Group A, with a significant difference observed in the 3D vector (mean ± SD: 1.62 ± 0.82 mm vs. 1.02 ± 0.42 mm; 95% CI [0.17, 0.86]; p = 0.007).Similarly, under audio guidance, Group B also exhibited smaller deviations, with a significant difference confirmed in the longitudinal direction (mean ± SD: 1.06 ± 0.78 mm vs. 0.45 ± 0.58 mm; 95% CI [0.16, 1.07]; p = 0.009). Table 3. Comparison of breath-hold reproducibility and patient preference between Group A and Group B using Student’s t-test (*: significance) Group A (Visual ⇒ Audio) (n = 20) Group B (Audio ⇒ Visual) (n = 20) 95% confidence interval P-value (Group A vs. Group B) Visual guidance Vertical [mm] 0.72 ± 0.46 0.49 ± 0.25 [− 0.01, 0.47] 0.0610 Lateral [mm] 0.68 ± 0.69 0.42 ± 0.25 [− 0.09, 0.59] 0.1385 Longitudinal[mm] 0.91 ± 0.89 0.55 ± 0.60 [− 0.14, 0.86] 0.1544 3D vector [mm] 1.62 ± 0.82 1.02 ± 0.42 [0.17, 0.86] 0.0072* Audio guidance Vertical [mm] 0.53 ± 0.39 0.69 ± 0.51 [− 0.46, 0.13] 0.2726 Lateral [mm] 0.59 ± 0.68 0.47 ± 0.18 [− 0.21, 0.44] 0.4757 Longitudinal[mm] 1.06 ± 0.78 0.45 ± 0.58 [0.16, 1.07] 0.0092* 3D vector [mm] 1.45 ± 0.94 1.07 ± 0.62 [− 0.14, 0.90] 0.1489 Which is favor? Visual: 13 Visual: 9 Audio: 6 Audio: 6 Both: 1 Both: 5 – Open in a new tab Although other directions did not reach statistical significance, most showed confidence intervals favoring Group B, suggesting a consistent trend toward improved reproducibility. These intergroup differences, however, may have been influenced by differences in treatment year (2009 vs. 2022) and equipment, rather than by methodological factors alone. Regarding patient preference between the two breath-hold methods, visual guidance was favored by more patients in both Group A and Group B. In total, 22 patients favored visual, 12 preferred audio, and 6 reported no preference. Discussion Respiratory motion arises from an integrated neurophysiological loop involving brainstem rhythm-generating circuits [ 18 ] and cortical networks that mediate volitional modulation of breathing [ 19 ]. Sensory feedback from pulmonary and thoracic mechanoreceptors is rapidly processed at the cortical level, as evidenced by respiratory-related evoked potentials detected with high-density EEG [ 20 ]. Furthermore, respiration interacts dynamically with large-scale cortical oscillatory networks in a phase-dependent manner [ 21 ], and interoceptive processing shapes individual variability in respiratory control [ 22 ]. Within this neurophysiological framework, visual biofeedback has been shown to enhance breath-hold consistency during radiotherapy [ 23 ]. Visual cues typically provide continuous, actively monitored information that facilitates moment-to-moment self-adjustment, whereas auditory guidance tends to be intermittent and passively received, potentially engaging a distinct breath-hold control mechanism [ 24 ]. Given the potential variability in individual patients’ aptitude for different feedback modalities, a respiratory indicator system that incorporates both approaches in a complementary manner is likely to offer greater clinical utility. In this context, the Abches system is a uniquely capable device, as it already integrates both functions within a single platform. In our previous study, we reported that there was no correlation between auditory and visual guidance in terms of breath-hold reproducibility on a per-patient basis, suggesting that the optimal guidance method should be determined individually [ 15 ]. However, a major limitation of that study was the fixed order in which the guidance methods were applied. In the present study, we addressed this limitation by including a new cohort in which the order of guidance was reversed, thereby enabling a more balanced comparison. The results were largely consistent with those of the previous study, further reinforcing the reliability of our earlier findings. The utility of audio-visual biofeedback in respiratory-gated radiotherapy has been explored in several previous studies [ 23 , 25 ]. George et al. investigated the effects of combined audio-visual feedback on respiratory-gated treatment and demonstrated that it effectively reduced intra-gating respiratory motion, as measured by the standard deviation of respiratory signals within the gating window [ 23 ]. Venkat et al. compared two types of visual feedback displays—a bar model and a wave model—and found that the wave display achieved over 50% and 70% reductions in displacement and period variability, respectively, compared with free breathing [ 25 ]. Similarly, Nakajima et al. assessed visual and audio-visual feedback using the Abches system in healthy volunteers and reported that both feedback modes improved respiratory stability compared with no feedback; however, direct comparisons between audio and visual guidance were not performed [ 26 ]. While these studies demonstrated the value of biofeedback for respiratory control, most focused on free-breathing or respiratory-gated treatments rather than voluntary breath-hold. Differences in study design, feedback methods, and monitoring systems also make direct comparison difficult. The present study extends previous work by directly comparing auditory and visual guidance during breath-hold in a clinical setting. Our current study revealed no significant differences of breath-hold reproducibility between preferences of guidance methods. In this study, 55% of patients (22/40) preferred visual guidance, 30% (12/40) preferred auditory guidance, and 15% (6/40) reported no preference. As there was no significant difference in breath-hold reproducibility between the visual and auditory methods, visual coaching appears to be the most appropriate option for approximately 70% of patients. However, considering that patients with visual impairments and roughly 30% of all participants preferred auditory feedback, allowing patient-specific selection may facilitate better continuity and adherence to breath-hold radiotherapy. Although the geometric differences observed in this study are small and, based on prior SBRT simulation and phantom studies, are expected to translate into only modest changes—typically ≤ 1% per millimeter in volume-based target dose metrics—across most clinical scenarios [ 27 – 29 ]. However, regions with very steep dose gradients, such as PTV–OAR interfaces, can still exhibit voxel-level dose differences on the order of 1–2 Gy per millimeter of displacement. Accordingly, even submillimeter to millimeter-scale uncertainties should be managed carefully when high-gradient regions are adjacent to critical organs. Recent systematic reviews have also highlighted the considerable inter-patient variation in breath-hold stability and reproducibility, particularly in upper abdominal radiotherapy. Farrugia et al. summarized data from 41 studies and reported a median cranio-caudal inter-fraction reproducibility of 0.6 mm in exhale breath-hold and greater variability in DIBH [ 30 ]. Our findings were largely consistent with these results. However, they noted that no single technique emerged as clearly superior, as the reported confidence intervals overlapped and the study methodologies differed in breath-hold definitions, imaging modalities, surrogate markers, and analysis criteria [ 30 ]. Although audio guidance was more frequently preferred by patients, preference did not consistently correlate with improved breath-hold reproducibility. Guidance selection based on post-CT image analysis yielded slightly better reproducibility than patient preference (mean difference < 0.5 mm per axis). While the magnitude of this difference is small and unlikely to have a major clinical impact in most conventional settings, it highlights the potential importance of objective evaluation using CT images over subjective preference when selecting guidance modes. As emphasized in AAPM TG-76, patient engagement and training are essential for effective respiratory management [ 31 ]. Accordingly, we advocate for a patient-centered approach, wherein the guidance modality is tailored based on both imaging feedback and individual patient characteristics. There are several limitations to the present study. First, there were notable differences between the 2009 and 2022 cohorts, with the latter demonstrating improved accuracy (Table 3 ). Several clearly identifiable technological advancements likely contributed to this improvement. One factor was the enhancement of CT image quality: the Hi Speed DX/i used in 2009 employed a single–detector-row system, whereas the Canon Aquilion LB used in 2022 had a 16-detector-row configuration, enabling more precise respiratory positional measurements. In addition, improvements in the operability of the Abches control software, along with nearly a decade of accumulated staff experience with Abches-based breath-hold techniques, may have further contributed to the superior performance observed in the 2022 cohort. Second, the study included a mix of inhalation and exhalation breath-hold techniques, with inhalation cases being predominant. For example, Kimura et al. reported that the end-expiration phase was more stable than the end-inspiration phase with respect to breath-hold reproducibility [ 32 ]. Therefore, further investigation focusing on exhalation breath-holds with a larger sample size is warranted. Third, regarding the auditory–visual system evaluated in this study, the optimal approach must be tailored to each patient, and therefore it does not inherently improve efficiency. Nonetheless, our findings show that both techniques can achieve acceptable breath-hold accuracy. Accordingly, for patients who cannot use one modality (e.g., those who are totally blind or have hearing impairment), the other can serve as a practical alternative. Devices that incorporate both modalities remain limited, and we believe that this dual functionality offers meaningful clinical benefit. Conclusion Regarding the reproducibility of breath-holding, both auditory and visual guidance methods demonstrated high precision. However, no significant differences were observed between the two approaches, and patient preference did not appear to affect reproducibility. Funding Open Access funding provided by University of Yamanashi Footnotes Publisher’s Note Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations. References 1. Kraus KM, Simonetto C, Kundrat P, et al. Potential morbidity reduction for lung stereotactic body radiation therapy using respiratory gating. Cancers (Basel). 2021. 10.3390/cancers13205092. [ DOI ] [ PMC free article ] [ PubMed ] [ Google Scholar ] 2. Shao K, Chen W, Xu Y, et al. Application of respiratory motion management technology for patients with lung cancer treated with stereotactic body radiotherapy (Review). Oncol Lett. 2025;30(3):415. [ DOI ] [ PMC free article ] [ PubMed ] [ Google Scholar ] 3. Wong JW, Sharpe MB, Jaffray DA, et al. The use of active breathing control (ABC) to reduce margin for breathing motion. Int J Radiat Oncol Biol Phys. 1999;44(4):911–9. [ DOI ] [ PubMed ] [ Google Scholar ] 4. Hanley J, Debois MM, Mah D, et al. Deep inspiration breath-hold teqnique for lung tumors: the potential value of target immobilization and reduced lung density in dose escalation. Int J Radiat Oncol Biol Phys. 1999;45(3):65. [ DOI ] [ PubMed ] [ Google Scholar ] 5. Shen S, Duan J, Fiveash JB, et al. Validation of target volume and position in respiratory gated CT planning and treatment. Med Phys. 2003;30(12):3196–205. [ DOI ] [ PubMed ] [ Google Scholar ] 6. Shirato H, Shimizu S, Kunieda T, et al. Physical aspects of a real-time tumor-tracking system for gated radiotherapy. Int J Radiat Oncol Biol Phys. 2000;48(4):1187–95. [ DOI ] [ PubMed ] [ Google Scholar ] 7. Ehrbar S, Braga Kaser S, Chamberlain M, et al. MR-guided beam gating: residual motion, gating efficiency and dose reconstruction for stereotactic treatments of the liver and lung. Radiother Oncol. 2022;174:101–8. [ DOI ] [ PubMed ] [ Google Scholar ] 8. Keall PJ, Joshi S, Vedam SS, et al. Four-dimensional radiotherapy planning for DMLC-based respiratory motion tracking. Med Phys. 2005;32(4):942–51. [ DOI ] [ PubMed ] [ Google Scholar ] 9. Nuyttens JJ, Prevost JB, Praag J, et al. Lung tumor tracking during stereotactic radiotherapy treatment with the CyberKnife: marker placement and early results. Acta Oncol. 2006;45(7):961–5. [ DOI ] [ PubMed ] [ Google Scholar ] 10. Saito M, Ozawa S, Komiyama T, et al. A Japanese national survey on IMRT/SBRT in 2023 by the JASTRO high-precision external beam radiotherapy group. J Radiat Res. 2025;66(3):234–52. [ DOI ] [ PMC free article ] [ PubMed ] [ Google Scholar ] 11. Ball HJ, Santanam L, Senan S, et al. Results from the AAPM Task Group 324 respiratory motion management in radiation oncology survey. J Appl Clin Med Phys. 2022;23(11):e13810. [ DOI ] [ PMC free article ] [ PubMed ] [ Google Scholar ] 12. Gaal S, Kahan Z, Paczona V, et al. Deep-inspirational breath-hold (DIBH) technique in left-sided breast cancer: various aspects of clinical utility. Radiat Oncol. 2021;16(1):89. [ DOI ] [ PMC free article ] [ PubMed ] [ Google Scholar ] 13. Tohyama N, Okamoto H, Shimomura K, et al. A national survey on the medical physics workload of external beam radiotherapy in Japandagger. J Radiat Res. 2023;64(6):911–25. [ DOI ] [ PMC free article ] [ PubMed ] [ Google Scholar ] 14. Onishi H, Kawakami H, Marino K, et al. A simple respiratory indicator for irradiation during voluntary breath holding: a one-touch device without electronic materials. Radiology. 2010;255(3):917–23. [ DOI ] [ PubMed ] [ Google Scholar ] 15. Sano N, Saito M, Onishi H, et al. Audio-visual biofeedback for respiratory motion management: comparison of the reproducibility of breath-holding between visual and audio guidance. J Mod Phys. 2018;09(13):2286–94. [ Google Scholar ] 16. Saito M, Kajihara D, Suzuki H, et al. Reproducibility of deep inspiration breath-hold technique for left-side breast cancer with respiratory monitoring device, Abches. J Appl Clin Med Phys. 2022. 10.1002/acm2.13529. [ DOI ] [ PMC free article ] [ PubMed ] [ Google Scholar ] 17. Saito M, Sano N, Ueda K, et al. Technical Note: Evaluation of the latency and the beam characteristics of a respiratory gating system using an Elekta linear accelerator and a respiratory indicator device, Abches. Med Phys. 2018;45(1):74–80. [ DOI ] [ PubMed ] [ Google Scholar ] 18. Feldman JL, Del Negro CA. Looking for inspiration: new perspectives on respiratory rhythm. Nat Rev Neurosci. 2006;7(3):232–42. [ DOI ] [ PMC free article ] [ PubMed ] [ Google Scholar ] 19. Herrero JL, Khuvis S, Yeagle E, et al. Breathing above the brain stem: volitional control and attentional modulation in humans. J Neurophysiol. 2018;119(1):145–59. [ DOI ] [ PMC free article ] [ PubMed ] [ Google Scholar ] 20. von Leupoldt A, Keil A, Davenport PW. Respiratory-related evoked potential measurements using high-density electroencephalography. Clin Neurophysiol. 2011;122(4):815–8. [ DOI ] [ PMC free article ] [ PubMed ] [ Google Scholar ] 21. Zelano C, Jiang H, Zhou G, et al. Nasal respiration entrains human limbic oscillations and modulates cognitive function. J Neurosci. 2016;36(49):12448–67. [ DOI ] [ PMC free article ] [ PubMed ] [ Google Scholar ] 22. Paulus MP, Stein MB. Interoception in anxiety and depression. Brain Struct Funct. 2010;214(5–6):451–63. [ DOI ] [ PMC free article ] [ PubMed ] [ Google Scholar ] 23. George R, Chung TD, Vedam SS, et al. Audio-visual biofeedback for respiratory-gated radiotherapy: impact of audio instruction and audio-visual biofeedback on respiratory-gated radiotherapy. Int J Radiat Oncol Biol Phys. 2006;65(3):924–33. [ DOI ] [ PubMed ] [ Google Scholar ] 24. Sabourin M, Rioux S. Effects of active and passive EMG biofeedback training on performance of motor and cognitive tasks. Percept Mot Skills. 1979;49(3):831–5. [ DOI ] [ PubMed ] [ Google Scholar ] 25. Venkat RB, Sawant A, Suh Y, et al. Development and preliminary evaluation of a prototype audiovisual biofeedback device incorporating a patient-specific guiding waveform. Phys Med Biol. 2008;53(11):N197-208. [ DOI ] [ PubMed ] [ Google Scholar ] 26. Nakajima Y, Kadoya N, Kanai T, et al. Comparison of visual biofeedback system with a guiding waveform and abdomen-chest motion self-control system for respiratory motion management. J Radiat Res. 2016. 10.1093/jrr/rrv106. [ DOI ] [ PMC free article ] [ PubMed ] [ Google Scholar ] 27. Han B, Wu B, Hu F, et al. Simulation of dosimetric consequences of intrafraction variation of tumor drift in lung cancer stereotactic body radiotherapy. Front Oncol. 2022;12:1010411. [ DOI ] [ PMC free article ] [ PubMed ] [ Google Scholar ] 28. Shang H, Pu Y, Wang Y. Robust optimization of SBRT planning for patients with early stage non-small cell lung cancer. Technol Cancer Res Treat. 2020;19:1533033820916505. [ DOI ] [ PMC free article ] [ PubMed ] [ Google Scholar ] 29. Saito M, Suzuki H, Sano N, et al. Evaluation of the target dose coverage of stereotactic body radiotherapy for lung cancer using helical tomotherapy: a dynamic phantom study. Rep Pract Oncol Radiother. 2020;25(2):200–5. [ DOI ] [ PMC free article ] [ PubMed ] [ Google Scholar ] 30. Farrugia B, Brown K, Knight K, et al. A systematic review of tumour position reproducibility and stability in breath-hold for radiation therapy of the upper abdomen. Phys Imaging Radiat Oncol. 2025;34:100751. [ DOI ] [ PMC free article ] [ PubMed ] [ Google Scholar ] 31. Keall PJ, Mageras GS, Balter JM, et al. The management of respiratory motion in radiation oncology report of AAPM task group 76. Med Phys. 2006;33(10):3874–900. [ DOI ] [ PubMed ] [ Google Scholar ] 32. Kimura T, Hirokawa Y, Murakami Y, et al. Reproducibility of organ position using voluntary breath-hold method with spirometer for extracranial stereotactic radiotherapy. Int J Radiat Oncol Biol Phys. 2004;60(4):1307–13. [ DOI ] [ PubMed ] [ Google Scholar ] Articles from Japanese Journal of Radiology are provided here courtesy of Springer ACTIONS View on publisher site PDF (2.2 MB) Cite Collections Permalink RESOURCES Similar articles Cited by other articles Links to NCBI Databases Follow NCBI NCBI on X (formerly known as Twitter) NCBI on Facebook NCBI on LinkedIn NCBI on GitHub NCBI RSS feed Connect with NLM NLM on X (formerly known as Twitter) NLM on Facebook NLM on YouTube National Library of Medicine 8600 Rockville Pike Bethesda, MD 20894 Web Policies FOIA HHS Vulnerability Disclosure Help Accessibility Careers NLM NIH HHS USA.gov Back to Top
Related documents
- NBTXR3 and Radiation Therapy in Treating Patients With Locally Advanced SCC of the Oral Cavity or Oropharynx#828410
- Effects of Different Flow Anesthesia on Atelectasis#1059622
- Monitoring of Lung Sounds of Patients With Pneumonia#1060473
- Lung Ventilation During Cardiopulmonary Resuscitation#866056
- Role of Lung Ultrasound Imaging in the Comparison of Two Mechanical Ventilation Strategies During Laparotomy#916823
Retrieved via Conceptio: every document is proof-bundled with source, license, and retrieval metadata.
Read the Docs → · View CLI source on GitHub · Conceptio Open Knowledge Archive