Conceptio › Archive › NCBI PubMed Central
NCBI PubMed Central open access

Evaluating the VOCORDER device for early disease detection through breath analysis: study protocol for a two-phase clinical study.

Kontopidou F et al. · ncbi_pmc
NCBI PubMed Central · Papers
Open Source ↗Direct PDF ↓
machine-learning-systems
Conceptio Open Archive

Analyze & explore related research in Conceptio

Connect this record directly into your research workflow or AI agent. Explore citations across open repositories, query full text, and export structured proof bundles.

Evaluating the VOCORDER device for early disease detection through breath analysis: study protocol for a two-phase clinical study - PMC Skip to main content An official website of the United States government Here's how you know Here's how you know Search Log in Primary site navigation Search Log in Search PMC Full-Text Archive Search in PMC Journal List User Guide As a library, NLM provides access to scientific literature. Inclusion in an NLM database does not imply endorsement of, or agreement with, the contents by NLM or the National Institutes of Health. Learn more: PMC Disclaimer | PMC Copyright Notice BMJ Open . 2026 Jun 3;16(6):e108562. doi: 10.1136/bmjopen-2025-108562 Evaluating the VOCORDER device for early disease detection through breath analysis: study protocol for a two-phase clinical study Flora Kontopidou 1, 0 , Stefan James Swift 2 , Christos Kokkotis 3, 0 , Serafeim Moustakidis 3, 0 , Ioannis Kavouras 4 , Anastasia Nefeli Vidaki 5, 0 , Sophia Brebou 1 , Vasileios Zavvos 6 , Angeliki Panagiotou 6 , Christos Iatrou 6 , Dimitrios Grosomanidis 7 , Zoe Zacharouli 1, 0 , Stamatios Giannoukos 2, ✉, 0 Author information Article notes Copyright and License information 1 Mitera Hospital, Athens, Greece 2 Department of Chemistry and Applied Biosciences, ETH, Zürich, Switzerland 3 AIDEAS OÜ, Tallinn, Estonia 4 National Technical University of Athens, Zografou, Greece 5 Vrije Universiteit Brussel, Brussel, Belgium 6 Center for Nephrology, Mitera Hospital, Athens, Greece 7 4th Breast Surgery Department, HYGEIA Hospital, Athens, Greece Supplemental material This content has been supplied by the author(s). It has not been vetted by BMJ Publishing Group Limited (BMJ) and may not have been peer-reviewed. Any opinions or recommendations discussed are solely those of the author(s) and are not endorsed by BMJ. BMJ disclaims all liability and responsibility arising from any reliance placed on the content. Where the content includes any translated material, BMJ does not warrant the accuracy and reliability of the translations (including but not limited to local regulations, clinical guidelines, terminology, drug names and drug dosages), and is not responsible for any error and/or omissions arising from translation and adaptation or otherwise. None declared. ✉ Dr Stamatios Giannoukos; stamatios.giannoukos@org.chem.ethz.ch 0 FK, CK, SM, ANV, ZZ and SG contributed equally. Received 2025 Jul 28; Accepted 2026 May 21; Collection date 2026. Copyright © Author(s) (or their employer(s)) 2026. Re-use permitted under CC BY-NC. No commercial re-use. See rights and permissions. Published by BMJ Group. This is an open access article distributed in accordance with the Creative Commons Attribution Non Commercial (CC BY-NC 4.0) license, which permits others to distribute, remix, adapt, build upon this work non-commercially, and license their derivative works on different terms, provided the original work is properly cited, appropriate credit is given, any changes made indicated, and the use is non-commercial. See: https://creativecommons.org/licenses/by-nc/4.0/ . PMC Copyright notice PMCID: PMC13239615  PMID: 42236089 Abstract Introduction The survival rate of patients with life-threatening diseases primarily depends on the speed of diagnosis. Too often, diseases are detected only after symptoms appear, which usually occurs at later stages of a disease when available treatments may be less effective. Current detection techniques primarily depend on identifying metabolites in biofluids such as blood and urine. The analysis of these fluids is typically performed in laboratories, resulting in lengthy waiting times for patients to receive their results. In severe cases, invasive biopsies and radiative methods are used to diagnose conditions such as cancer. These biopsies can cause distress for patients who are already experiencing significant emotional or physical stress, while imaging techniques involving ionising radiation may pose additional health risks. Additionally, these methods can be costly. In recent years, exhaled breath has become a biofluid matrix of interest for disease detection, allowing for the identification of volatile organic compounds (VOCs) or VOC profiles associated with specific conditions. To improve early disease detection through breath analysis, the VOCORDER project aims to develop a device that provides a fast, simple, user-friendly and cost-effective method for continuous health monitoring to identify diseases in their early stages before symptoms appear. Methods and analyses A literature review was initially conducted to identify five reference diseases of interest (lung cancer, stomach/colon cancer, breast cancer and kidney insufficiency) and previously reported VOC profiles associated with these diseases. In this trial, the project team from the MITERA Hospital will select patients, and the hospital staff will conduct personal interviews with these subjects. Each participant will also complete a questionnaire for the acquisition of demographic and medical history data, after being informed in detail about the purposes of the questionnaire and signing a consent form. The study protocol consists of two phases. Phase 1 is a baseline study designed to detect and identify breath biomarkers for the early diagnosis of the diseases mentioned above using gas chromatography-mass spectrometry (GC-MS) and secondary electrospray ionisation high-resolution mass spectrometry (SESI-HR-MS). Prescreening will select 120 healthy controls and 175 patients for the baseline phase of the clinical trial, for which breath samples will be collected in 1 L Supel-Inert Multi-Layer Foil gas sampling bags. New biomarkers and VOC profiles will be extracted from these data, and further statistical analysis will allow for artificial intelligence (AI) models to be produced and tested. For phase 2 (validation phase), 120 healthy controls and 100 patients will be selected. Breath samples will again be collected in 1 L gas sampling bags for analyses with GC-MS and SESI-HR-MS. The VOCORDER device will also be used, and its functioning with the newly developed AI models will be evaluated. Ethics and dissemination This clinical study has been approved by the scientific council at the MITERA hospital in Athens, Greece (#513/2024). The outcomes will be disseminated through peer-reviewed journal publications and presentations at scientific conferences. Trial registration number NCT06711939 . Keywords: Clinical Trial, Methods, Biochemistry, Breast tumours Strengths and limitations of this study. The development of the VOCORDER device will offer a non-invasive online breath analysis technique in the clinical setting. The instrumentation used for offline analysis during the baseline and validation phases includes gas chromatography-mass spectrometry (GC-MS) and secondary electrospray ionisation high-resolution mass spectrometry (SESI-HR-MS). The SESI-HR-MS offers high resolution with minimal fragmentation (softer than ESI) and is user-friendly. However, this technique is semi-quantitative. The GC-MS provides orthogonal separation of sample molecules based on retention time and mass-to-charge ratio (m/z), enabling compound identification using reference spectral libraries. In the baseline phase, the use of reference methods (GC-MS and SESI-HR-MS) may enable the identification of novel breath biomarkers associated with the diseases under investigation. The study will not use the same cohort of patients for the baseline and validation phases due to the elapsed time between these sampling periods. Patients may either be cured, have progressed to a new stage of the disease, or may no longer be available for sampling. Introduction Each year, millions of premature deaths worldwide result from a lack of early disease diagnosis 1 for conditions including heart disease, sepsis, Alzheimer’s, chronic obstructive pulmonary disease, diabetes and cancers. 1 , 3 While treatments are available for these diseases to extend and improve a patient’s life, early detection is vital for increasing the survival rate. 2 4 Unfortunately, symptoms often appear in the more advanced stages of a disease, 3 5 when treatment success rates are significantly lower. 6 7 Modern diagnostic methods are costly and time-consuming and must be performed in specialised laboratories. 8 , 10 They cannot be repeated frequently within short time intervals, and this applies to both invasive and non-invasive tests. Moreover, a significant number of these methods, particularly in the context of preventive care, remain inaccessible to the general population. 11 , 13 Therefore, it is essential to develop accurate, non-invasive diagnostic tools that can be routinely used in the clinical setting to improve patient survival rates. The onset of disease disrupts the body’s biochemistry and metabolic processes, leading to the production of metabolites that are excreted in biofluids such as urine, sweat and breath. 114 , 21 These metabolic changes can occur even before symptoms appear, providing a basis for early disease detection. 114 16 22 , 25 Volatile organic compounds (VOCs), a subset of these metabolites, pass from the bloodstream into the lungs via the alveoli and are exhaled in breath. 2 26 Analysing these VOCs using gas-phase analytical techniques can reveal biomarkers linked to specific metabolic processes, offering insights into the presence and progression of disease. 3 10 14 25 26 Human exhaled breath is a complex sample containing thousands of VOCs within a matrix of oxygen, nitrogen, carbon dioxide and water. 727 , 32 In recent years, this biological fluid has become the focus of an emerging field of analytical research known as breath metabolomics. 27 33 Breath sampling can be performed non-intrusively 814 16 27 29 34 , 37 on patients and exhibits a chemical complexity that enables the potential identification of unique VOC signatures among individuals. 3 14 21 31 37 Within these VOC profiles, certain VOCs have been reported as biomarkers for specific diseases, and their detection may indicate the presence of a disease in an individual. 7 8 26 29 30 38 Several studies have effectively investigated breath analysis using advanced mass spectrometric techniques to assess emitted VOCs in the gas phase. These techniques, including selected ion flow tube mass spectrometry (SIFT-MS), 39 , 46 proton transfer reaction MS, 47 , 51 secondary electrospray ionisation high-resolution MS (SESI-HR-MS) 52 , 59 and gas chromatography-MS (GC-MS), 60 , 67 offer highly sensitive and accurate detection capabilities. Their potential to provide detailed molecular insights makes them valuable tools for breath analysis, with ongoing advancements (lower limits of detection and quantification, fast response times) further improving their efficiency and applicability for a variety of research and clinical purposes. Other techniques have also been exploited and tested for use in breath analysis. E-sensors, 68 69 for example, can detect species such as CO, NO, ethanol and ammonia. 1 7 They are made up of a series of sensors which mimic human olfactory systems 1 3 37 and are size and cost-effective 1 3 14 22 37 70 although they exhibit low sensitivities 7 and lack physical and chemical control, resulting in reproducibility issues. 3 16 Wearable sensors and optical methods have also been used in breath analysis research. 7 22 29 37 While breath analysis holds significant promise for non-invasive early disease detection, the complexity of VOC profiles arising from metabolic and environmental variability presents challenges for accurate interpretation. 71 , 75 Several factors influence an individual’s VOC profile, including both endogenous factors (such as underlying genetic conditions) and exogenous sources (such as exposure to air pollution, smoking and alcohol). 7 26 27 As a result, the quality and accuracy of data for disease detection through breath analysis remain challenging. Thus, identifying VOC profiles and patterns provides a more robust approach to disease detection in breath analysis, rather than relying solely on the presence of individual biomarker species. This project aims to develop a user-friendly breath analysis tool for regular health monitoring in various settings. The goal is to create a device that seamlessly integrates into the healthcare system for routine use, demonstrating effectiveness and accuracy in clinical environments. An ideal breath analysis device would offer a quick, simple, affordable, reliable and precise method for ongoing assessments, with the capability to detect diseases at their earliest stages, even before symptoms arise, through the use of artificial intelligence (AI). Such a device could significantly improve patient survival rates, reduce emotional stress on families and lower costs for government-funded healthcare services. To achieve this vision, the European Union-funded VOCORDER project is advancing a new breath analysis technology called ‘VOCORDER’. This system employs a laser-based approach to analyse breath, simultaneously detecting small quantities of gases at specific concentrations, enabling accurate and early disease identification. The study is a single-centre clinical trial conducted in two phases. Phase 1 is a baseline study focused on detecting and identifying breath biomarkers for the early diagnosis of lung, stomach, colon and breast cancers and kidney insufficiency. This phase uses SESI-HR-MS and GC-MS to analyse breath samples from 120 healthy participants and 175 patients (at least 35 per disease group). Phase 2 aims to validate the newly developed portable breath analyser in a cohort of 120 healthy controls and 100 patients with the aforementioned diseases. Breath samples will also be collected in 1 L gas sampling bags at MITERA Hospital in Athens, Greece, and will be analysed in the breath analysis laboratory at ETH Zürich in Switzerland, using SESI-HR-MS. This manuscript outlines the clinical trial protocol for developing and validating the VOCORDER device, designed for continuous health monitoring and early disease detection. It also describes the methods used to identify new biomarker species and aims to expand the library of breath-associated biomarkers linked to the selected diseases focused on in this work. Hypothesis and objectives Hypothesis It is hypothesised that exhaled breath VOCs and their concentrations will show patterns that can be correlated to specific diseases under certain conditions compared with healthy controls. We aim to develop, test and validate an analyser that enables in situ concentration measurement of VOCs in separate breath samples from participants, featuring a user-friendly and intuitive interface. Primary objectives The primary objectives are to develop and validate a user-friendly breath analysis device (VOCORDER) for lifelong health monitoring and predictive medicine. The project aims to ensure that the device is easily integrated into daily life, minimises false positives and meets clinical standards. It includes validating the device’s accuracy in distinguishing between patient VOC profiles and those of healthy individuals, correlating breath VOCs with electronic medical records, benchmarking against established methods and exploring links between breath-detected gases and specific diseases. Methods and analysis The VOCORDER project is a single-centre, observational study aimed at deciphering correlations between VOC profiles from a human breath matrix and the presence of a specific illness, with the goal of engineering a new method for disease identification and early detection through breath analysis. The project comprises a consortium of 12 contributing partners, including Mitera Hospital, Alpes Lasers SA, Eidgenössische Materialprüfungs- und Forschungsanstalt (EMPA), UAB Metis Baltic, Neuraltech IKE, Vrije Universiteit Brussel, EULAMBIA Advanced Technologies, Cailabs, Argos Messtechnik, AiDEAS OU, Institute of Communications and Computer Systems (Athens, Greece) and ETH Zürich (Switzerland). Study design The clinical trial is divided into two phases: the baseline (October 2024–May 2025) and validation (May–December 2026) and will take place at Mitera Hospital in Athens, Greece. Patients and healthy controls will be selected and enrolled through a prescreening process that includes a questionnaire and a personal interview. The staff at Mitera will enter the information from participant questionnaires and interviews into electronic records. Breath samples will be collected and stored in 1 L Supel-Inert Multi-Layer Foil gas sampling bags. These samples will then be analysed offline using GC-MS and SESI-HR-MS during both the baseline and validation phases and with the newly developed VOCORDER device introduced in the validation phase. The baseline phase will be used to identify the optimal operating parameters of the VOCORDER device in preparation for the validation phase. Using the selected diseases as the foundation for the statistical models, we will identify correlations in the breath matrix and new biomarkers for these diseases. The selection of these diseases was based on a literature review conducted by consortium members at ETH Zürich. AI algorithms will be developed using electronic medical records and mass spectral data obtained from offline analyses. The resulting AI models will then be used in the validation phase to assess the performance of the VOCORDER device. By using the gold-standard reference methods of GC-MS and SESI-HR-MS, the baseline phase presents significant opportunities to explore and identify new breath biomarker species potentially linked to a specific disease in its early stages. It also facilitates the testing of prototype AI models in preparation for the validation phase, during which the VOCORDER device will be assessed alongside the gold-standard techniques. Figure 1 provides a general overview of the study design. Figure 1. Overview of the study protocol for the VOCORDER clinical trial. AI, artificial intelligence; ATH, Athens; GC-MS, gas chromatography-mass spectrometry; SESI-HR-MS, secondary electrospray ionisation high-resolution mass spectrometry; ZRH, Zurich. Open in a new tab Regular reports on ethics risk monitoring will be provided during project meetings. The formulation and distribution of an ethics questionnaire internally to the partners involved in the technical advancement is under consideration to ensure alignment with the ethical requirements. The internal ethics committee will be responsible for addressing any questions raised by the project partners at all times and cooperating with the respective representatives of legal and ethical matters defined by each entity. VOCORDER will assess its outcomes at all phases of the project implementation against these requirements to ensure comprehensive coverage. Sampling Sampling will take place at MITERA Hospital in Athens, Greece, which has been operating for over 45 years. MITERA is a private hospital that offers general, paediatric and maternity/gynaecological clinics. It is the leading healthcare centre in Greece, specialising in paediatric medicine, although it provides care for individuals of all ages. The hospital staff and the research team will conduct sampling at MITERA Hospital. For the healthy control cohort, a minimum of 120 participants will be involved in both the baseline and validation phases. A breath sample will be collected from each participant on the sampling day at the same time. The same control group is expected to be involved in both the baseline and validation phases of the study. For the patient cohort, 175 patients will participate in the baseline phase and 100 patients will participate in the validation phase. This represents 35 and 20 patients for each disease during the respective phases of the study. A breath sample will be collected from each subject on different days, although they will be taken at the same time of day. The patients in the baseline and validation phases will predominantly consist of different individuals. This is due to the time elapsed between these two sampling stages (approximately 1 to 2 years). Patients may either be cured, progress to a different stage of the disease or become unavailable for sampling. Both patients and healthy controls will provide breath samples in 1 L gas sampling bags, filling them up to 80% capacity. GC-MS (Agilent Technology, Santa Clara, California, USA) and SESI-HR-MS (Fossil Ion Technology, SL, Q Exactive Orbitrap, Thermo Fisher Scientific) equipment represent the analytical gold standard reference methods for VOC identification and quantification available for this study and have been widely utilised in breath analysis studies. 52 , 67 In the baseline phase, these mass spectrometric techniques will be employed to analyse the samples. During the validation phase, the samples will also be processed using the newly developed VOCORDER device. The sample and data analysts will be blinded to the participant’s group status (healthy controls or patients). Participants and eligibility criteria Healthy controls A minimum of 240 healthy control participants will be recruited for both the baseline phase (120 participants) and the validation phase (120 participants) of the study. Participants will be selected from both genders (as assigned at birth), must be over 18 years old, and must not currently suffer from any of the diseases under investigation in this study. Healthy controls must also be available to participate in both phases of the clinical trial, provided they remain healthy throughout the study. Patients 55 patients will be recruited for each disease, totalling 275 patients, across both genders (as assigned at birth) and aged 18 years or older. A total of 175 patients will be required for the baseline phase and 100 patients for the validation phase. Subjects will be selected based on the following inclusion and exclusion criteria. Inclusion criteria The criteria for inclusion for both phases are as follows: Patients must be over 18 years old. Patients should be able to communicate and understand the information given by the staff at Mitera Hospital. Participants must suffer from only one of the conditions selected for investigation in this study. The disease must be detected as soon as possible; no treatment can be started for the patient yet (essential). There must be no other severe acute or chronic disease that could affect the measurements (desirable). Patients will be selected in collaboration with the clinicians responsible for the treatment and/or hospitalisation of patients with the diseases under investigation. Further disease-specific requirements for enrolling patients in the study are outlined below. For patients with cancer, the type of cancer must be determined based on histopathological data and specific result indicators. The disease stage must also be established through haematological and radiological examinations. For kidney insufficiency, proof of chronic kidney disease is required, including the establishment of the disease stage as indicated by the case fatality rates, along with any evidence of haemodialysis treatment. This medical evidence must be available for successful enrolment. Exclusion criteria The exclusion criteria for both phases include: The lack of signed consent. The inability to cooperate with project staff under any circumstances. Failure to adhere to the necessary instructions and requirements of the sampling procedure. Inability to provide the necessary breath sample. Currently undergoing any form of treatment or intervention (such as a specific diet or surgery) between breath sample acquisitions. Description of the collected data The factors associated with the incidence of disease represent a complex area. An extensive evaluation of factors for various health conditions reveals an intricate interplay among genetic predisposition, environmental exposures, lifestyle choices and underlying health issues. The questionnaire developed for the VOCORDER project aims to identify potential factors that may influence the outcomes of analysing the five diseases of interest in patients. A summary of these risk factors is displayed in table 1 . The risk factors may be either endogenous to the individual, such as their genetic makeup, or exogenous, concerning exposure to toxic substances. By identifying the risk factors associated with each patient, the presence of certain VOCs in breath may be clarified, enhancing the data quality assurance of the VOC profiles linked to specific diseases. Table 1. Summary table of potential factors that may influence the pattern of breath samples for the five diseases studied in the VOCORDER clinical trial. Disease Exposure factors Biological factors Lung cancer Smoking Radon Asbestos Air pollution Metals Occupational exposure Family history Gastric/colon cancer Diet Smoking Helicobacter pylori Family history Breast cancer Hormone therapy Alcohol consumption Obesity Physical inactivity Early menarche Late menopause Gene mutations (eg, in the BRCA1 and BRCA2 gene) Reproductive history (breastfeeding, age at first childbirth) Kidney insufficiency Chronic use of onsteroidal Anti-Inflammatory Drugs (NSAIDs) Contrast dyes Diabetes Hypertension Family history Age Ethnicity Open in a new tab NSAIDs, Nonsteroidal Anti-Inflammatory Drugs. As part of the prescreening process, a comprehensive questionnaire will collect demographic and general health information from participants. This questionnaire will include inquiries about a patient’s geographical location, marital status, occupation, education level, income, race and ethnicity, gender and age. It will also cover their medical history, comorbidities, physical activity levels, diet, alcohol consumption, smoking habits, height, weight, body mass index (BMI) and mental health. Additionally, it will gather information on hospitalisations, surgeries, medication use, and the presence of infections or chronic diseases. Furthermore, questions regarding occupational exposure, stress levels, sleep patterns, genetic predispositions, and other lifestyle and environmental influences will be included. These inquiries will explore a patient’s risk factors, and the responses will be integrated into statistical models during the data analysis stage. The collected responses will also help explain and identify specific VOC patterns exhibited by a subject and assist in pinpointing which endogenous and metabolic processes lead to a particular VOC profile for a specific disease. Recruitment and screening procedure The recruitment process is as follows: The attending physician, based on predefined criteria, determines whether the patient is eligible to participate in the study and provides them with initial information. If the patient agrees to participate, the study team takes over, offering a detailed explanation and obtaining written informed consent ( online supplemental appendix 1 ). This is followed by an interview and data collection. The healthy controls will consist of either hospital staff or patients at the Mitera Hospital who have been admitted under different circumstances. For the baseline phase, 120 healthy controls and 175 patients are needed. In the validation phase, 120 healthy controls and 100 new patients will be recruited, respectively. Both the healthy controls and the patients considered for this study will complete a comprehensive questionnaire. This questionnaire will collect information on medical history (hospitalisations, surgeries, medications, infections, chronic diseases, comorbidities, physical activity, dietary habits, alcohol consumption, smoking habits, BMI, height and weight) as well as demographic data (ethnicity, gender, age, marital status, occupation, education level). Additionally, questions regarding lifestyle, environmental exposure, genetic predispositions and psychological factors will also be included ( table 2 ). The study aims to recruit an equal number of male and female participants. Age, sex, BMI and smoking status will be recorded for all participants via the study questionnaire and included as covariates in all statistical models. Propensity-score-based sensitivity analyses will be used to assess the robustness of VOC-disease associations to any residual demographic imbalance between groups. Table 2. Type of collected data from healthy individuals and patients enrolled in the study. Type of collected data Healthy individuals Patients Demographics X X Factors which influence an individual’s VOC profile Lifestyle X X Comorbidities X X Drugs X X Family medical history X X Other substances X X Previous hospitalisation X X Current hospitalisation X Screening examination tests (haematological test, X-ray, endoscopy, mammogram) X X Indicators related to the study diseases X X Open in a new tab VOC, volatile organic compound. Outcomes Primary outcomes To evaluate the effectiveness of the VOCORDER device in the clinical setting and to encourage further research into breath analysis. Secondary outcomes To determine and describe the operational features of the new VOCORDER technology for breath analysis and health monitoring in a clinical setting. To evaluate the results, performance and data quality of the VOCORDER device and compare these results with comparable data from the reference methods, GC-MS and SESI-HR-MS. To investigate the correlations and statistical significance of noteworthy VOC markers or profiles in subjects with known pre-existing diseases, aiming to identify the significant biomarkers associated with the selected diseases in this study. To evaluate the potential use of the VOCORDER device for early disease detection from the human breath matrix, allowing for critical early patient diagnosis of disease by identifying correlations of VOC biomarkers with important medical parameters. Instrumentation Secondary electrospray ionisation high-resolution mass spectrometry The SESI-HR-MS technique was specifically developed for use in breath analysis studies and has been extensively used in previous research investigating the human exhalome. 52 , 59 Its main advantages include being non-invasive, operating in real time and producing high-resolution full-scan spectra, reaching up to approximately 1000 Da. This allows for the potential identification of new specific biomarkers of disease. 76 , 78 In the study detailed here, the breath sample is stored in a gas sampling bag that connects to the SESI-HR-MS inlet. This setup allows the sample to flow through a heated capillary into the ionisation chamber. A high voltage is applied to a 0.1% formic acid aqueous solution, creating an ionising electrospray. The stability of this electrospray is continuously monitored using a nano-ammeter to ensure a consistent signal during the analysis. The mass spectrometer is calibrated at least weekly in both ionisation modes, which is essential for preserving the system’s high sensitivity and selectivity. Furthermore, the stability of the system is evaluated with gas standards of breath VOCs, such as acetone, and a labelled compound (butyric acid-d 7 ), to detect any deviations on a daily basis. Specifically, our lab monitors the stability of the SESI-HR-MS system three times daily during the last 2 years using a gas standard of butyric acid-d 7 . In addition, a microquantity of acetone-d6 standard is introduced in the bags as an internal standard. In the ionisation chamber, ion-molecule reactions occur between electrospray droplets and sample VOC, resulting in the VOC becoming charged and detectable by an Orbitrap detector. In the positive mode, the dominant ion produced is the MH + ion (proton transfer species), while in negative mode, the (M-H, M minus H ) - ion (hydride transfer species) prevails. However, sufficient ionisation energy is necessary to produce these ionised species. However, selected ions from the Orbitrap may undergo collision-induced dissociation through tandem MS (MS 2 ) analysis, enhancing specificity and accuracy in compound identification, including the ability to measure isomers separately. The molecular formula of a species can be determined using high mass accuracy and resolution (to five decimal places of m/z ) as well as isotopic abundance ratios. The limits of detection can reach down to sub-ppt levels. The heated capillary and ionisation chamber for sample injection prevent the loss of VOC to the walls of the transfer line through condensation, particularly for species with higher molecular masses, which are common in biologically significant and disease-specific metabolites found in breath. The larger the identified metabolite, the more likely it is that the single specific compound will be unique to the prevalence of a particular disease. The SESI-HR-MS can measure up to 1000 Da (with a resolution of 140 000), potentially enabling the discovery of new metabolites related to the diseases of interest. Additionally, the heated system eliminates any delays in responses to concentrations. For the breath samples collected during the VOCORDER clinical trial described in this publication, the mass range used for spectral analysis is 50–500 m/z . The instrument has a resolution of 140 000 with an automatic gain control target of 5×10 6 ; a maximum injection time of 200 ms; a sheath gas flow rate of 15 a.u. (arbitrary unit); an auxiliary gas flow rate of 2 a.u.; an electrospray voltage of 3.5 kV; a capillary temperature of 250°C; an S-lens RF amplitude of 50.0; and measurements taken in both positive and negative modes. Gas chromatography-mass spectrometry The breath samples will also be analysed using a GC-MS system to validate and enhance the VOC analysis of the SESI-HR-MS technique. GC-MS is an orthogonal technique and a standard reference method previously employed in breath analysis research. For the offline analysis of samples from this clinical trial, a handheld pump (ACTI-VOC low-flow pump kit, Markes International Ltd, UK) will be used to transfer breath VOCs from the gas sampling bag to preconditioned hydrophobic stainless-steel tubes (Markes International, UK). These tubes are sealed and stored in the refrigerator until they are transported to the laboratory for analysis. A standard thermal desorption system will be used to extract the VOCs from the samples into the GC-MS system (Agilent GC-7890B coupled to an Agilent MSD-5977B, Agilent Technology, Santa Clara, California, USA). Calibration methods for offline techniques Calibration methods for SESI-HR-MS and GC-MS rely on external gas standards for quantification. Three calibration systems are used to generate trace VOC gas standards across a wide concentration range (ppt–ppm). The first is a commercial gas cylinder-based system that mixes VOC standards with humidified air to simulate breath, with concentrations controlled by nitrogen dilution. The second, an in-house system at ETH Zürich, injects liquid standards into evaporation chambers, applying Henry’s Law to calculate gas concentrations before mixing with humidified nitrogen. The third system modifies a commercial permeation tube unit (OVG-4, Owlstone Medical Ltd, UK) to adjust VOC concentrations via nitrogen flows. These methods offer flexibility but require careful handling to minimise artefacts from VOC interactions. The VOCORDER device The VOCORDER device is based on IR measurements using a self-mixing quantum cascade laser mid-IR array-based analyser capable of measuring VOCs at concentrations ranging from 10 to 100 ppb. It offers a resolution of approximately ±1 ppb and a limit of detection of 1 ppb. By using the National Institute of Standards and Technology mass spectral library as a reference, the device can identify and quantify VOCs. Data analysis procedure Based on a literature review, we will investigate lung, gastric, colon and breast cancer and kidney insufficiency. According to our literature search, a subject’s breath profile changes depending on the incidence of disease, which is qualitatively summarised in table 3 . The selection of biomarkers was also adapted to the detection capabilities of the developed technology. Different diseases may lead to varying concentrations of the selected exhaled breath VOC and, subsequently, different profiles. Therefore, these compounds will be used to test the VOCORDER device within the clinical environment, and the selection of biomarkers to be measured was also adapted to the technical capabilities of the LASER methodology. Table 3. Summary of VOC biomarker profiles from breath for five selected diseases to be investigated as part of the VOCORDER clinical trial. Lung cancer Gastric/colon cancer Breast cancer Kidney insufficiency Acetone X X X Ammonia X Ethanol X X Ethylene X X X Isoprene X X X X Methanol X X Open in a new tab VOC, volatile organic compound. With this prior knowledge, a statistical analysis of the GC-MS and SESI-HR-MS breath sample spectral data will be conducted alongside clinical data obtained from questionnaires and personal interviews with patients. Utilising the diseases of interest and the previous understanding of VOCs associated with these conditions ( table 3 ), AI techniques will differentiate between sample categories based on the participants’ health status. AI techniques, including semi-supervised, supervised and unsupervised learning methods, will draw on established machine learning approaches from the existing literature to support the exploration of statistical dependencies and correlations among breath matrices, spectral patterns, disease parameters and potential new biomarkers identified during the baseline phase. Techniques may include advanced classification methods such as decision trees and more complex models like Convolutional Neural Networks. XAI technologies will also be employed to improve model interpretability and enhance the overall accuracy of the statistical analyses. The prespecified AI training pipeline will be structured as follows. For each disease group, binary classifiers will be developed independently (disease vs healthy controls), with a secondary multi-class ensemble explored using a one-vs-rest strategy. This staged approach constrains model complexity relative to the available sample size. Feature selection will be based on literature-supported biomarker relevance combined with univariate statistical filtering (Mann-Whitney U test with Benjamini-Hochberg false discovery rate correction, q<0.05), applied exclusively to training data within each cross-validation fold to prevent data leakage. A stratified fivefold nested cross-validation scheme will be employed, with the outer loop providing an unbiased estimate of generalisation performance and the inner loop used for hyperparameter optimisation. An additional independent hold-out set (20% of each cohort) will be withheld prior to any analysis and used solely as the final performance benchmark. AI training and validation safeguards are built into the pipeline at multiple levels. First, nested cross-validation (five outer folds, three inner folds) ensures strict separation between model selection and performance estimation, preventing data leakage. Second, the adversarial deconfounding architecture structurally penalises retention of demographic information in the learnt representation, providing a formal guard against confound-driven bias. Third, all trained models, hyperparameter configurations and random seeds will be archived in a versioned GitHub repository (DOI-registered via Zenodo) to ensure full reproducibility. Fourth, SHAP (SHapley Additive exPlanations) values will be computed for each prediction to provide clinician-interpretable feature attribution and support regulatory auditability. All preprocessing steps—including imputation, scaling and feature selection—will be fitted exclusively on training folds and applied to test folds without exception. Class imbalance between disease patients and healthy controls will be addressed using class-weighted loss functions and stratified sampling during training. Model performance will be reported using the full confusion matrix, AUC-ROC, balanced accuracy, sensitivity, specificity, positive predictive value, negative predictive value and calibration curves. SHAP values will be computed for all models to identify the VOC features driving classification decisions and to provide clinical interpretability. Sample size calculation The sample size calculation was based on the objective of diagnosing each disease using binary machine learning classifiers (disease vs healthy controls). A specificity and sensitivity of over 90% are required to differentiate between healthy controls and each specific disease of interest. Using a one-proportion z-test, it was determined that at least 35 subjects would be necessary per disease group in the baseline phase and 20 in the validation phase, resulting in a 95% confidence level (±10%). The 10% error margin exceeds the standard 5% typically used in clinical trials but was maintained within the VOCORDER clinical trial due to the exploratory, first-in-device nature of the study, consistent with precedent in breath biomarker protocol studies of comparable cohort size. The analytical strategy proceeds from binary disease-specific classifiers to a secondary multiclass ensemble, constraining model complexity relative to sample size. To mitigate overfitting risk, nested cross-validation, an independent hold-out set, regularisation and SHAP-based dimensionality reduction will be employed, as described in the Data Analysis Procedure. Multiple hypothesis testing across VOC features will be controlled using the Benjamini-Hochberg false discovery rate correction. A total of 240 healthy participants are required across both phases. The primary power calculation pertains to binary (disease vs healthy control) comparisons, which represent the fundamental inferential unit of this study. Multiclass discrimination across all five disease categories will be conducted as a secondary, exploratory analysis. To control the familywise error rate across multiple disease comparisons, Benjamini-Hochberg false discovery rate correction will be applied. Each pairwise classifier retains the statistical power established by the binary calculation, since the one-vs-rest decomposition preserves the effective sample size per comparison. The healthy participant cohort needed to be significantly larger than the patient subjects to account for natural discrepancies observed in some diseases, such as the higher incidence of breast cancer among women compared with men. Consequently, 240 healthy participants were required. This consideration is crucial for developing unbiased machine learning AI techniques. Ethics and dissemination Participation in the VOCORDER clinical trial is entirely voluntary. A comprehensive information sheet outlining the procedures, risks and objectives of the project, along with a trained physician providing a verbal explanation to participants in Greek (a language spoken by all participants), will be available. Individual participants must provide consent, and a consent form will be signed. For those who are illiterate, non-written consent will be obtained and independently witnessed. The data collected from the questionnaires and personal interviews will be compiled by the MITERA research team and uploaded onto a secure network, with access restricted solely to the VOCORDER project research team. Patient data will also be anonymised. Data scrubbing may be permitted once the request has been evaluated and there is no hindrance to achieving the project aims. Patient and public involvement Patients were not involved in the design of this clinical study. However, they will contribute to dissemination activities concerning the acceptance of the VOCORDER device and study outcomes, particularly through communication materials tailored to patients and the general public (questionnaires). The project results will be published in open-access journals, presented at national and international conferences and communicated to the public and other relevant stakeholders via the communication channels of all investigators and project partners. All results derived from the study will be accessible, in line with the European Union and the State Secretariat for Education, Research and Innovation open access policy. If an external scientist wishes to access the GC-MS and SESI-HR-MS breath data, there are straightforward options to do so (for example, setting up a guest account at ETH that provides VPN access). Such access will be granted on reasonable request. Data statement The data will be collected and managed by the MITEPA project team and stored in a computerised working folder within the hospital. This folder is only accessible to the MITERA project team. Patient-related data will then be anonymised and entered into a specially developed database shared with authorised partners. The database will also include results from both methodologies. The protection of patients’ personal data will be ensured in accordance with Greek legislation, the relevant European General Data Protection Regulation and MITERA hospital regulations. Data availability The original data generated by the study will be accessible in a curated data archive at ETH Zurich ( https://www.research-collection.ethz.ch ), the so-called ‘green way’ for open access. Discussion The accuracy of VOCORDER technology is fundamentally determined by the spectral information obtained during the baseline and validation phases of the clinical trials analysing breath samples. The study’s advantages include (a) it is a prospective study and (b) the diagnosis of the diseases under investigation occurs before the initiation of treatment. Regarding the limitations, the small sample size is a factor; however, all reference studies also involve a small number of patients. Samples will be collected in 1 L Supel-Inert Multi-Layer Foil gas sampling bags, based on previous studies 79 , 81 as well as preliminary tests conducted in-house observing the change in VOC concentrations over 1 week, which showed reduced occurrence of positive or negative artefacts (often problematic in offline sampling techniques). Despite the effectiveness of the sampling bags for storing breath samples and the fact that offline breath samples are analysed as soon as possible, the analyses are nonetheless still conducted offline, and the formation of potential artefacts must be taken into account. One potential source of artefacts that may be concerning is the pressure changes that occur during the transportation of samples. The 1 L sampling bags are transported from Greece to Zürich (approximately a 3-hour flight). Future quality assurance efforts should focus on determining whether the mix of VOCs in a breath sample could be affected by these pressure changes over the course of a flight. One potential method to investigate this is to directly measure a participant’s breath online in addition to collecting a breath sample in a 1 L gas sampling bag. However, the analytical instruments would have needed to be available at the clinical trial site, which they were not. This test would however help demonstrate how the breath matrix and the presence of specific biological metabolites of interest could change in response to external stimuli. Furthermore, while gas sampling bags are a strong option for storing breath samples and conducting offline chemical analyses, the loss of specific VOC species is unavoidable, particularly for the larger, more specific biomarker metabolite molecules. To avoid potential artefacts, the future directions of this work will consider online analyses. Online analyses have been used in several prior breath studies, 82 , 89 although the logistics of the VOCORDER clinical trial made it impractical on this occasion. To further enhance the study, incorporating an additional analysis method that enables online real-time measurements of VOCs in the gas phase and serves as a quantitative technique would be beneficial. SIFT-MS has been used in prior breath analysis studies, 39 , 46 sampling both online and offline specimens. A notable advantage of SIFT-MS is its ability to separately quantify isomers by switching between different reagent ions, which exhibit unique ion-molecule reactions. 90 For both online and offline measurement techniques used for breath analysis, another potential source of error may arise from environmental artefacts. 2627 91 , 93 VOC concentrations in the breath can be altered in situ, depending on a participant’s lifestyle or exposure to external sources of VOCs (eg, air pollution). 10 26 27 93 Breath VOC concentrations may also shift based on a subject’s medication, use of cosmetics, level of physical exercise and circadian rhythm. 94 , 97 Consequently, accurately measuring a VOC profile and correlating it with disease incidence becomes increasingly challenging. The spectra and data obtained from the GC-MS and SESI-HR-MS, along with the medical data from questionnaires and personal interviews, will be input into statistical AI models. Five reference diseases (based on a literature review conducted by our group) have been used as a foundation for the investigation ( table 1 ) into the correlations between VOC matrix profiles of patients with specific disease incidences. These models developed during the baseline phase will be used for the newly developed VOCORDER device to enable early disease detection using the discovered VOC profile patterns. The use of unsupervised AI models for statistical analysis of breath samples has previously been investigated as a method for detecting cancer from breath, employing principal component analysis. Maiti et al 22 used a laser-free broadband mid-infrared Fourier-transform spectroscopy technique to analyse breath samples for metabolite VOCs from patients with prostate, bladder and kidney cancers. However, they report that further work is required. Aslam et al 98 also explored unsupervised methods to assess the possibility of diagnosing gastric cancer in the early stages of disease, demonstrating an overall accuracy of 97.3% in early diagnosis. Another study that exploited unsupervised AI models is that of Alkhalifah et al . 99 Similar to our work, the authors acquired GC-MS data from participants’ breath samples. These authors employed a data clustering technique to identify similarities in the spectra from the samples. Semi-supervised and supervised AI machine learning approaches have previously been used for the detection of SARS-CoV-2 (COVID-19). 100 Additionally, work by Shi et al 101 successfully developed a deep transfer learning method to identify lung cancer incidence by detecting nodules in patients’ lungs. Supervised AI machine learning techniques were applied in a study to detect leukaemia biomarkers from breath 102 and for lung cancer detection. 103 In all these prior works, the potential of AI methods for early disease detection has been demonstrated. However, the research community has identified a need for further study before these techniques can become standard in medical practice. Supplementary material online supplemental file 1 bmjopen-16-6-s001.pdf (215.3KB, pdf) DOI: 10.1136/bmjopen-2025-108562 Acknowledgements The authors extend their sincere thanks to the entire project consortium: Mitera Hospital, Alpes Lasers SA, EMPA, UAB Metis Baltic, Neuraltech IKE, Vrije Universiteit Brussel, EULAMBIA Advanced Technologies, Cailabs, Argos Messtechnik, AiDEAS OU, ICCS and ETH Zürich. Special acknowledgments to the personnel of Mitera Hospital for their support and facilitation of breath sample collection. Footnotes Funding: The research leading to this review paper has received funding from the VOCORDER project, which is co-funded by the European Union under grant agreement 101115442 and the State Secretariat for Education, Research and Innovation (SERI), REF-1131-52304/SBFI-Nr.23.00369. Prepublication history and additional supplemental material for this paper are available online. To view these files, please visit the journal online ( https://doi.org/10.1136/bmjopen-2025-108562 ). Provenance and peer review: Not commissioned; externally peer reviewed. Patient consent for publication: Not applicable. Patient and public involvement: Patients and/or the public were not involved in the design, or conduct, or reporting, or dissemination plans of this research. References 1. Maiti KS. Non-Invasive Disease Specific Biomarker Detection Using Infrared Spectroscopy: A Review. Molecules. 2023;28:2320. doi: 10.3390/molecules28052320. [ DOI ] [ PMC free article ] [ PubMed ] [ Google Scholar ] 2. Maiti KS, Roy S, Lampe R, et al. Detection of disease-specific volatile organic compounds using infrared spectroscopy. International Workshop on Advanced Infrared Technology & Applications; 2021. p. 15. Available. [ DOI ] [ Google Scholar ] 3. Maiti KS. Analysis of volatile metabolites using vibrational spectroscopy. International Workshop on Advanced Infrared Technology and Applications; 2023. p. 46. Available. [ DOI ] [ Google Scholar ] 4. Crosby D, Bhatia S, Brindle KM, et al. Early detection of cancer. Science. 2022;375:eaay9040. doi: 10.1126/science.aay9040. [ DOI ] [ PubMed ] [ Google Scholar ] 5. Maiti KS, Apolonski A. Monitoring the Reaction of the Body State to Antibiotic Treatment against Helicobacter pylori via Infrared Spectroscopy: A Case Study. Molecules. 2021;26:3474. doi: 10.3390/molecules26113474. [ DOI ] [ PMC free article ] [ PubMed ] [ Google Scholar ] 6. DeKosky S. Early intervention is key to successful management of Alzheimer disease. Alzheimer Dis Assoc Disord. 2003;17 Suppl 4:S99–104. doi: 10.1097/00002093-200307004-00004. [ DOI ] [ PubMed ] [ Google Scholar ] 7. Wojtas J, Bielecki Z, Stacewicz T, et al. Ultrasensitive laser spectroscopy for breath analysis. Opto-Electronics Review. 2012;20:26–39. doi: 10.2478/s11772-012-0011-4. [ DOI ] [ Google Scholar ] 8. Roy S, Hauer J, Maiti KS. Development of non-invasive diagnosis based on FTIR spectroscopy. Vib Spectrosc. 2024;134:103724. doi: 10.1016/j.vibspec.2024.103724. [ DOI ] [ Google Scholar ] 9. Newman-Toker DE, McDonald KM, Meltzer DO. How much diagnostic safety can we afford, and how should we decide? A health economics perspective. BMJ Qual Saf. 2013;22 Suppl 2:ii11–20. doi: 10.1136/bmjqs-2012-001616. [ DOI ] [ PMC free article ] [ PubMed ] [ Google Scholar ] 10. Haick H, Broza YY, Mochalski P, et al. Assessment, origin, and implementation of breath volatile cancer markers. Chem Soc Rev. 2014;43:1423–49. doi: 10.1039/c3cs60329f. [ DOI ] [ PMC free article ] [ PubMed ] [ Google Scholar ] 11. Marrocco A, Krouse HJ. Obstacles to preventive care for individuals with disability: Implications for nurse practitioners. J Am Assoc Nurse Pract. 2017;29:282–93. doi: 10.1002/2327-6924.12449. [ DOI ] [ PubMed ] [ Google Scholar ] 12. Merten JW, Pomeranz JL, King JL, et al. Barriers to cancer screening for people with disabilities: a literature review. Disabil Health J. 2015;8:9–16. doi: 10.1016/j.dhjo.2014.06.004. [ DOI ] [ PubMed ] [ Google Scholar ] 13. Le Bonniec A, Sun S, Andrin A, et al. Barriers and Facilitators to Participation in Health Screening: an Umbrella Review Across Conditions. Prev Sci. 2022;23:1115–42. doi: 10.1007/s11121-022-01388-y. [ DOI ] [ PubMed ] [ Google Scholar ] 14. Feddahi N, Hartmann L, Felderhoff-Müser U, et al. Neonatal Exhaled Breath Sampling for Infrared Spectroscopy: Biomarker Analysis. ACS Omega. 2024;9:30625–35. doi: 10.1021/acsomega.4c02635. [ DOI ] [ PMC free article ] [ PubMed ] [ Google Scholar ] 15. Metzler DE. Elsevier; 2003. Biochemistry (2 volume set): the chemical reactions of living cells. [ Google Scholar ] 16. Maiti KS, Lewton M, Fill E, et al. Human beings as islands of stability: Monitoring body states using breath profiles. Sci Rep. 2019;9:16167. doi: 10.1038/s41598-019-51417-0. [ DOI ] [ PMC free article ] [ PubMed ] [ Google Scholar ] 17. Huber M, Kepesidis KV, Voronina L, et al. Stability of person-specific blood-based infrared molecular fingerprints opens up prospects for health monitoring. Nat Commun. 2021;12:1511. doi: 10.1038/s41467-021-21668-5. [ DOI ] [ PMC free article ] [ PubMed ] [ Google Scholar ] 18. Shirasu M, Touhara K. The scent of disease: volatile organic compounds of the human body related to disease and disorder. J Biochem. 2011;150:257–66. doi: 10.1093/jb/mvr090. [ DOI ] [ PubMed ] [ Google Scholar ] 19. Drabińska N, Flynn C, Ratcliffe N, et al. A literature survey of all volatiles from healthy human breath and bodily fluids: the human volatilome. J Breath Res. 2021;15:034001. doi: 10.1088/1752-7163/abf1d0. [ DOI ] [ PubMed ] [ Google Scholar ] 20. Mi K, Jiang Y, Chen J, et al. Construction and Analysis of Human Diseases and Metabolites Network. Front Bioeng Biotechnol. 2020;8:398. doi: 10.3389/fbioe.2020.00398. [ DOI ] [ PMC free article ] [ PubMed ] [ Google Scholar ] 21. Apolonski A, Roy S, Lampe R, et al. Molecular identification of bio-fluids in gas phase using infrared spectroscopy. Appl Opt. 2020;59:E36–41. doi: 10.1364/AO.388362. [ DOI ] [ PubMed ] [ Google Scholar ] 22. Maiti KS, Fill E, Strittmatter F, et al. Towards reliable diagnostics of prostate cancer via breath. Sci Rep. 2021;11:18381. doi: 10.1038/s41598-021-96845-z. [ DOI ] [ PMC free article ] [ PubMed ] [ Google Scholar ] 23. Maiti KS, Fill E, Strittmatter F, et al. Standard operating procedure to reveal prostate cancer specific volatile organic molecules by infrared spectroscopy. Spectrochim Acta A Mol Biomol Spectrosc. 2024;304:123266. doi: 10.1016/j.saa.2023.123266. [ DOI ] [ PubMed ] [ Google Scholar ] 24. Gowda GAN, Zhang S, Gu H, et al. Metabolomics-based methods for early disease diagnostics. Expert Rev Mol Diagn. 2008;8:617–33. doi: 10.1586/14737159.8.5.617. [ DOI ] [ PMC free article ] [ PubMed ] [ Google Scholar ] 25. Amal H, Haick H. In: Advanced nanomaterials for inexpensive gas microsensors: synthesis, integration and applications. Llobet E, editor. Elsevier; 2020. Point of care breath analysis systems; pp. 315–34. Available. [ DOI ] [ Google Scholar ] 26. Sharma A, Kumar R, Varadwaj P. Smelling the Disease: Diagnostic Potential of Breath Analysis. Mol Diagn Ther. 2023;27:321–47. doi: 10.1007/s40291-023-00640-7. [ DOI ] [ PMC free article ] [ PubMed ] [ Google Scholar ] 27. Lawal O, Ahmed WM, Nijsen TME, et al. Exhaled breath analysis: a review of “breath-taking” methods for off-line analysis. Metabolomics (Los Angel) 2017;13:110. doi: 10.1007/s11306-017-1241-8. [ DOI ] [ PMC free article ] [ PubMed ] [ Google Scholar ] 28. Lourenço C, Turner C. Breath analysis in disease diagnosis: methodological considerations and applications. Metabolites. 2014;4:465–98. doi: 10.3390/metabo4020465. [ DOI ] [ PMC free article ] [ PubMed ] [ Google Scholar ] 29. Ates HC, Dincer C. Wearable breath analysis. Nat Rev Bioeng . 2023;1:80–2. doi: 10.1038/s44222-022-00011-7. [ DOI ] [ Google Scholar ] 30. Gelin MF, Blokhin AP, Ostrozhenkova E, et al. Theory helps experiment to reveal VOCs in human breath. Spectrochim Acta A Mol Biomol Spectrosc. 2021;258:119785. doi: 10.1016/j.saa.2021.119785. [ DOI ] [ PubMed ] [ Google Scholar ] 31. Mathew TL, Pownraj P, Abdulla S, et al. Technologies for Clinical Diagnosis Using Expired Human Breath Analysis. Diagnostics (Basel) 2015;5:27–60. doi: 10.3390/diagnostics5010027. [ DOI ] [ PMC free article ] [ PubMed ] [ Google Scholar ] 32. Gouma P, Stanacevic M. Selective Nanosensor Array Microsystem For Exhaled Breath Analysis. Procedia Eng. 2011;25:1557–60. doi: 10.1016/j.proeng.2011.12.385. [ DOI ] [ PubMed ] [ Google Scholar ] 33. Beale DJ, Jones OAH, Karpe AV, et al. A Review of Analytical Techniques and Their Application in Disease Diagnosis in Breathomics and Salivaomics Research. Int J Mol Sci. 2016;18:24. doi: 10.3390/ijms18010024. [ DOI ] [ PMC free article ] [ PubMed ] [ Google Scholar ] 34. Fuchs P, Loeseken C, Schubert JK, et al. Breath gas aldehydes as biomarkers of lung cancer. Int J Cancer. 2010;126:2663–70. doi: 10.1002/ijc.24970. [ DOI ] [ PubMed ] [ Google Scholar ] 35. Miekisch W, Schubert JK, Noeldge-Schomburg GFE. Diagnostic potential of breath analysis—focus on volatile organic compounds. Clinica Chimica Acta . 2004;347:25–39. doi: 10.1016/j.cccn.2004.04.023. [ DOI ] [ PubMed ] [ Google Scholar ] 36. Vaks VL, Domracheva EG, Sobakinskaya EA, et al. Exhaled breath analysis: physical methods, instruments, and medical diagnostics. Phys-Usp. 2014;57:684–701. doi: 10.3367/UFNe.0184.201407d.0739. [ DOI ] [ Google Scholar ] 37. Roy S, Maiti KS. Baseline correction for the infrared spectra of exhaled breath. Spectrochim Acta A Mol Biomol Spectrosc. 2024;318:124473. doi: 10.1016/j.saa.2024.124473. [ DOI ] [ PubMed ] [ Google Scholar ] 38. Maiti KS, Lewton M, Fill E, et al. Sensitive spectroscopic breath analysis by water condensation. J Breath Res. 2018;12:046003. doi: 10.1088/1752-7163/aad207. [ DOI ] [ PubMed ] [ Google Scholar ] 39. Spaněl P, Smith D. Progress in SIFT-MS: breath analysis and other applications. Mass Spectrom Rev. 2011;30:236–67. doi: 10.1002/mas.20303. [ DOI ] [ PubMed ] [ Google Scholar ] 40. Smith D, Španěl P, Demarais N, et al. Recent developments and applications of selected ion flow tube mass spectrometry (SIFT-MS) Mass Spectrom Rev. 2025;44:101–34. doi: 10.1002/mas.21835. [ DOI ] [ PMC free article ] [ PubMed ] [ Google Scholar ] 41. Španěl P, Smith D. Quantification of volatile metabolites in exhaled breath by selected ion flow tube mass spectrometry, SIFT-MS. Clin Mass Spectrom. 2020;16:18–24. doi: 10.1016/j.clinms.2020.02.001. [ DOI ] [ PMC free article ] [ PubMed ] [ Google Scholar ] 42. Senthilmohan ST, Milligan DB, McEwan MJ, et al. Quantitative analysis of trace gases of breath during exercise using the new SIFT-MS technique. Redox Rep. 2000;5:151–3. doi: 10.1179/135100000101535537. [ DOI ] [ PubMed ] [ Google Scholar ] 43. Belluomo I, Whitlock SE, Myridakis A, et al. Combining Thermal Desorption with Selected Ion Flow Tube Mass Spectrometry for Analyses of Breath Volatile Organic Compounds. Anal Chem. 2024;96:1397–401. doi: 10.1021/acs.analchem.3c04286. [ DOI ] [ PMC free article ] [ PubMed ] [ Google Scholar ] 44. Belluomo I, Boshier PR, Myridakis A, et al. Selected ion flow tube mass spectrometry for targeted analysis of volatile organic compounds in human breath. Nat Protoc. 2021;16:3419–38. doi: 10.1038/s41596-021-00542-0. [ DOI ] [ PubMed ] [ Google Scholar ] 45. Španěl P, Spesyvyi A, Smith D. Electrostatic Switching and Selection of H3O+, NO+, and O2+• Reagent Ions for Selected Ion Flow-Drift Tube Mass Spectrometric Analyses of Air and Breath. Anal Chem. 2019;91:5380–8. doi: 10.1021/acs.analchem.9b00530. [ DOI ] [ PubMed ] [ Google Scholar ] 46. Dryahina K, Smith D, Bortlík M, et al. Pentane and other volatile organic compounds, including carboxylic acids, in the exhaled breath of patients with Crohn’s disease and ulcerative colitis. J Breath Res. 2017;12:016002. doi: 10.1088/1752-7163/aa8468. [ DOI ] [ PubMed ] [ Google Scholar ] 47. Schwarz K, Filipiak W, Amann A. Determining concentration patterns of volatile compounds in exhaled breath by PTR-MS. J Breath Res. 2009;3:027002. doi: 10.1088/1752-7155/3/2/027002. [ DOI ] [ PubMed ] [ Google Scholar ] 48. Schwoebel H, Schubert R, Sklorz M, et al. Phase-resolved real-time breath analysis during exercise by means of smart processing of PTR-MS data. Anal Bioanal Chem. 2011;401:2079–91. doi: 10.1007/s00216-011-5173-2. [ DOI ] [ PubMed ] [ Google Scholar ] 49. Moser B, Bodrogi F, Eibl G, et al. Mass spectrometric profile of exhaled breath--field study by PTR-MS. Respir Physiol Neurobiol. 2005;145:295–300. doi: 10.1016/j.resp.2004.02.002. [ DOI ] [ PubMed ] [ Google Scholar ] 50. Pleil JD, Hansel A, Beauchamp J. Advances in proton transfer reaction mass spectrometry (PTR-MS): applications in exhaled breath analysis, food science, and atmospheric chemistry. J Breath Res. 2019;13:039002. doi: 10.1088/1752-7163/ab21a7. [ DOI ] [ PMC free article ] [ PubMed ] [ Google Scholar ] 51. Herbig J, Müller M, Schallhart S, et al. On-line breath analysis with PTR-TOF. J Breath Res. 2009;3:027004. doi: 10.1088/1752-7155/3/2/027004. [ DOI ] [ PubMed ] [ Google Scholar ] 52. Singh KD, Tancev G, Decrue F, et al. Standardization procedures for real-time breath analysis by secondary electrospray ionization high-resolution mass spectrometry. Anal Bioanal Chem. 2019;411:4883–98. doi: 10.1007/s00216-019-01764-8. [ DOI ] [ PMC free article ] [ PubMed ] [ Google Scholar ] 53. Martínez-Lozano P, Zingaro L, Finiguerra A, et al. Secondary electrospray ionization-mass spectrometry: breath study on a control group. J Breath Res. 2011;5:016002. doi: 10.1088/1752-7155/5/1/016002. [ DOI ] [ PubMed ] [ Google Scholar ] 54. Singh KD, Del Miguel GV, Gaugg MT, et al. Translating secondary electrospray ionization-high-resolution mass spectrometry to the clinical environment. J Breath Res. 2018;12:027113. doi: 10.1088/1752-7163/aa9ee3. [ DOI ] [ PubMed ] [ Google Scholar ] 55. Gaugg MT, Gomez DG, Barrios-Collado C, et al. Expanding metabolite coverage of real-time breath analysis by coupling a universal secondary electrospray ionization source and high resolution mass spectrometry--a pilot study on tobacco smokers. J Breath Res. 2016;10:016010. doi: 10.1088/1752-7155/10/1/016010. [ DOI ] [ PubMed ] [ Google Scholar ] 56. Zhu J, Bean HD, Jiménez-Díaz J, et al. Secondary electrospray ionization-mass spectrometry (SESI-MS) breathprinting of multiple bacterial lung pathogens, a mouse model study. J Appl Physiol (1985) 2013;114:1544–9. doi: 10.1152/japplphysiol.00099.2013. [ DOI ] [ PMC free article ] [ PubMed ] [ Google Scholar ] 57. Blanco FG, Vidal-de-Miguel G. Breath Analysis by Secondary Electro-Spray Ionization - Mass Spectrometry to Interrogate Biologically Significant Metabolites Non-Invasively. Crit Rev Anal Chem. 2023;53:825–37. doi: 10.1080/10408347.2021.1981226. [ DOI ] [ PubMed ] [ Google Scholar ] 58. Berchtold C, Meier L, Steinhoff R, et al. A new strategy based on real-time secondary electrospray ionization and high-resolution mass spectrometry to discriminate endogenous and exogenous compounds in exhaled breath. Metabolomics (Los Angel) 2014;10:291–301. doi: 10.1007/s11306-013-0568-z. [ DOI ] [ Google Scholar ] 59. García-Gómez D, Gaisl T, Bregy L, et al. Real-Time Quantification of Amino Acids in the Exhalome by Secondary Electrospray Ionization-Mass Spectrometry: A Proof-of-Principle Study. Clin Chem. 2016;62:1230–7. doi: 10.1373/clinchem.2016.256909. [ DOI ] [ PubMed ] [ Google Scholar ] 60. Lamote K, Brinkman P, Vandermeersch L, et al. Breath analysis by gas chromatography-mass spectrometry and electronic nose to screen for pleural mesothelioma: a cross-sectional case-control study. Oncotarget. 2017;8:91593–602. doi: 10.18632/oncotarget.21335. [ DOI ] [ PMC free article ] [ PubMed ] [ Google Scholar ] 61. Saidi T, Zaim O, Moufid M, et al. Exhaled breath analysis using electronic nose and gas chromatography–mass spectrometry for non-invasive diagnosis of chronic kidney disease, diabetes mellitus and healthy subjects. Sens Actuators B Chem. 2018;257:178–88. doi: 10.1016/j.snb.2017.10.178. [ DOI ] [ Google Scholar ] 62. Wang XR, Cassells J, Berna AZ. Stability control for breath analysis using GC-MS. J Chromatogr B Analyt Technol Biomed Life Sc. 2018;1097–1098:27–34. doi: 10.1016/j.jchromb.2018.08.024. [ DOI ] [ PMC free article ] [ PubMed ] [ Google Scholar ] 63. Beccaria M, Bobak C, Maitshotlo B, et al. Exhaled human breath analysis in active pulmonary tuberculosis diagnostics by comprehensive gas chromatography-mass spectrometry and chemometric techniques. J Breath Res. 2019;13:016005. doi: 10.1088/1752-7163/aae80e. [ DOI ] [ PMC free article ] [ PubMed ] [ Google Scholar ] 64. Ibrahim W, Cordell RL, Wilde MJ, et al. Diagnosis of COVID-19 by exhaled breath analysis using gas chromatography–mass spectrometry. ERJ Open Res. 2021;7:00139–2021. doi: 10.1183/23120541.00139-2021. [ DOI ] [ PMC free article ] [ PubMed ] [ Google Scholar ] 65. Deng C, Zhang J, Yu X, et al. Determination of acetone in human breath by gas chromatography–mass spectrometry and solid-phase microextraction with on-fiber derivatization. J Chromatogr B Analyt Technol Biomed Life Sci. 2004;810:269–75. doi: 10.1016/j.jchromb.2004.08.013. [ DOI ] [ PubMed ] [ Google Scholar ] 66. Gashimova E, Osipova A, Temerdashev A, et al. Exhaled breath analysis using GC-MS and an electronic nose for lung cancer diagnostics. Anal Methods. 2021;13:4793–804. doi: 10.1039/d1ay01163d. [ DOI ] [ PubMed ] [ Google Scholar ] 67. Buszewski B, Ulanowska A, Ligor T, et al. Analysis of exhaled breath from smokers, passive smokers and non-smokers by solid-phase microextraction gas chromatography/mass spectrometry. Biomed Chromatogr. 2009;23:551–6. doi: 10.1002/bmc.1141. [ DOI ] [ PubMed ] [ Google Scholar ] 68. Karakaya D, Ulucan O, Turkan M. Electronic Nose and Its Applications: A Survey. Int J Autom Comput. 2020;17:179–209. doi: 10.1007/s11633-019-1212-9. [ DOI ] [ Google Scholar ] 69. Ye Z, Liu Y, Li Q. Recent Progress in Smart Electronic Nose Technologies Enabled with Machine Learning Methods. Sensors (Basel) 2021;21:7620. doi: 10.3390/s21227620. [ DOI ] [ PMC free article ] [ PubMed ] [ Google Scholar ] 70. Apolonski A, Maiti KS. Towards a standard operating procedure for revealing hidden volatile organic compounds in breath: the Fourier-transform IR spectroscopy case. Appl Opt. 2021;60:4217–24. doi: 10.1364/AO.421994. [ DOI ] [ PubMed ] [ Google Scholar ] 71. Salman D, Ibrahim W, Kanabar A, et al. The variability of volatile organic compounds in the indoor air of clinical environments. J Breath Res. 2021;16:016005. doi: 10.1088/1752-7163/ac3565. [ DOI ] [ PubMed ] [ Google Scholar ] 72. Gaude E, Nakhleh MK, Patassini S, et al. Targeted breath analysis: exogenous volatile organic compounds (EVOC) as metabolic pathway-specific probes. J Breath Res. 2019;13:032001. doi: 10.1088/1752-7163/ab1789. [ DOI ] [ PubMed ] [ Google Scholar ] 73. Trefz P, Schmidt M, Oertel P, et al. Continuous real time breath gas monitoring in the clinical environment by proton-transfer-reaction-time-of-flight-mass spectrometry. Anal Chem. 2013;85:10321–9. doi: 10.1021/ac402298v. [ DOI ] [ PubMed ] [ Google Scholar ] 74. Bajo-Fernández M, Souza-Silva ÉA, Barbas C, et al. GC-MS-based metabolomics of volatile organic compounds in exhaled breath: applications in health and disease. A review. Front Mol Biosci . 2023;10:1295955. doi: 10.3389/fmolb.2023.1295955. [ DOI ] [ PMC free article ] [ PubMed ] [ Google Scholar ] 75. Walsh CM, Fadel MG, Jamel SH, et al. Breath Testing in the Surgical Setting: Applications, Challenges, and Future Perspectives. Eur Surg Res. 2023;64:315–22. doi: 10.1159/000531504. [ DOI ] [ PMC free article ] [ PubMed ] [ Google Scholar ] 76. Zeng J, Christen A, Dev Singh K, et al. Comparison of Plasma Ionization- and Secondary Electrospray Ionization- High-resolution Mass Spectrometry for Real-time Breath Analysis. Chimia (Aarau) 2022;76:127–32. doi: 10.2533/chimia.2022.127. [ DOI ] [ PubMed ] [ Google Scholar ] 77. Kaeslin J, Wüthrich C, Giannoukos S, et al. How Soft Is Secondary Electrospray Ionization? J Am Soc Mass Spectrom. 2022;33:1967–74. doi: 10.1021/jasms.2c00201. [ DOI ] [ PubMed ] [ Google Scholar ] 78. Käser T, Giannoukos S, Zenobi R. Challenges in the identification and quantitation in on-line breath analysis. J Breath Res. 2025;19:036002. doi: 10.1088/1752-7163/adc9da. [ DOI ] [ PubMed ] [ Google Scholar ] 79. Hooghiem JJD, de Vries M, Been HA, et al. LISA: a lightweight stratospheric air sampler. Atmos Meas Tech. 2018;11:6785–801. doi: 10.5194/amt-11-6785-2018. [ DOI ] [ Google Scholar ] 80. Abruzzi RC, Bonetti B, Pires MJR, et al. Artifacts in the analysis and assessment of low-cost containers for sampling and storing greenhouse gases. Quim Nova. 2018;42:84–94. doi: 10.21577/0100-4042.20170299. [ DOI ] [ Google Scholar ] 81. Menoud M, van der Veen C, Lowry D, et al. New contributions of measurements in Europe to the global inventory of the stable isotopic composition of methane. Earth Syst Sci Data. 2022;14:4365–86. doi: 10.5194/essd-14-4365-2022. [ DOI ] [ Google Scholar ] 82. Zambrana Tevar F, Herrero A, Vidal-de-Miguel G, et al. On-line breath analysis of volatile organic compounds as a method for colorectal cancer detection. JCO. 2012;30:1570. doi: 10.1200/jco.2012.30.15_suppl.1570. [ DOI ] [ Google Scholar ] 83. Bruderer T, Gaisl T, Gaugg MT, et al. On-Line Analysis of Exhaled Breath. Chem Rev. 2019;119:10803–28. doi: 10.1021/acs.chemrev.9b00005. [ DOI ] [ PubMed ] [ Google Scholar ] 84. Kononov A, Korotetsky B, Jahatspanian I, et al. Online breath analysis using metal oxide semiconductor sensors (electronic nose) for diagnosis of lung cancer. J Breath Res. 2019;14:016004. doi: 10.1088/1752-7163/ab433d. [ DOI ] [ PubMed ] [ Google Scholar ] 85. Wang Y, Jiang J, Hua L, et al. High-Pressure Photon Ionization Source for TOFMS and Its Application for Online Breath Analysis. Anal Chem. 2016;88:9047–55. doi: 10.1021/acs.analchem.6b01707. [ DOI ] [ PubMed ] [ Google Scholar ] 86. López-Lorente CI, Awchi M, Sinues P, et al. Real-time pharmacokinetics via online analysis of exhaled breath. J Pharm Biomed Anal. 2021;205:114311. doi: 10.1016/j.jpba.2021.114311. [ DOI ] [ PubMed ] [ Google Scholar ] 87. Weber R, Streckenbach B, Welti L, et al. Online breath analysis with SESI/HRMS for metabolic signatures in children with allergic asthma. Front Mol Biosci. 2023;10:1154536. doi: 10.3389/fmolb.2023.1154536. [ DOI ] [ PMC free article ] [ PubMed ] [ Google Scholar ] 88. Kalidoss R, Umapathy S. A comparison of online and offline measurement of exhaled breath for diabetes pre-screening by graphene-based sensor; from powder processing to clinical monitoring prototype. J Breath Res. 2019;13:036008. doi: 10.1088/1752-7163/ab09ae. [ DOI ] [ PubMed ] [ Google Scholar ] 89. Weber R, Haas N, Baghdasaryan A, et al. Volatile organic compound breath signatures of children with cystic fibrosis by real-time SESI-HRMS. ERJ Open Res. 2020;6:00171-2019. doi: 10.1183/23120541.00171-2019. [ DOI ] [ PMC free article ] [ PubMed ] [ Google Scholar ] 90. Swift SJ, Dryahina K, Lehnert A-S, et al. Accurate selected ion flow tube mass spectrometry quantification of ethylene oxide contamination in the presence of acetaldehyde. Anal Methods. 2023;15:6435–43. doi: 10.1039/D3AY01036H. [ DOI ] [ PubMed ] [ Google Scholar ] 91. Martin AN, Farquar GR, Jones AD, et al. Human breath analysis: methods for sample collection and reduction of localized background effects. Anal Bioanal Chem. 2010;396:739–50. doi: 10.1007/s00216-009-3217-7. [ DOI ] [ PubMed ] [ Google Scholar ] 92. Pleil JD, Stiegel MA, Risby TH. Clinical breath analysis: discriminating between human endogenous compounds and exogenous (environmental) chemical confounders. J Breath Res. 2013;7:017107. doi: 10.1088/1752-7155/7/1/017107. [ DOI ] [ PubMed ] [ Google Scholar ] 93. Filipiak W, Ruzsanyi V, Mochalski P, et al. Dependence of exhaled breath composition on exogenous factors, smoking habits and exposure to air pollutants. J Breath Res. 2012;6:036008. doi: 10.1088/1752-7155/6/3/036008. [ DOI ] [ PMC free article ] [ PubMed ] [ Google Scholar ] 94. Henderson B, Lopes Batista G, Bertinetto CG, et al. Exhaled Breath Reflects Prolonged Exercise and Statin Use during a Field Campaign. Metabolites. 2021;11:192. doi: 10.3390/metabo11040192. [ DOI ] [ PMC free article ] [ PubMed ] [ Google Scholar ] 95. Liotino V, Dragonieri S, Quaranta VN, et al. Influence of circadian rhythm on exhaled breath profiling by electronic nose. J Biol Regul Homeost Agents. 2018;32:1261–5. [ PubMed ] [ Google Scholar ] 96. Wilkinson M, Maidstone R, Loudon A, et al. Circadian rhythm of exhaled biomarkers in health and asthma. Eur Respir J. 2019;54:1901068. doi: 10.1183/13993003.01068-2019. [ DOI ] [ PMC free article ] [ PubMed ] [ Google Scholar ] 97. Sasiene ZJ, LeBrun ES, Schaller E, et al. Real-time breath analysis towards a healthy human breath profile. J Breath Res. 2024;18:026003. doi: 10.1088/1752-7163/ad1cf1. [ DOI ] [ PubMed ] [ Google Scholar ] 98. Aslam MA, Xue C, Chen Y, et al. Breath analysis based early gastric cancer classification from deep stacked sparse autoencoder neural network. Sci Rep. 2021;11:4014. doi: 10.1038/s41598-021-83184-2. [ DOI ] [ PMC free article ] [ PubMed ] [ Google Scholar ] 99. Alkhalifah Y, Phillips I, Soltoggio A, et al. VOCCluster: Untargeted Metabolomics Feature Clustering Approach for Clinical Breath Gas Chromatography/Mass Spectrometry Data. Anal Chem. 2020;92:2937–45. doi: 10.1021/acs.analchem.9b03084. [ DOI ] [ PubMed ] [ Google Scholar ] 100. Khattar A, Ouadri SMK. A semi-supervised domain adaptation approach for diagnosing SARS-CoV-2 and its variants of concern (VOC). 2021 9th International Conference on Reliability, Infocom Technologies and Optimization (Trends and Future Directions) (ICRITO); Noida, India. 2021. pp. 1–9. Available. [ DOI ] [ Google Scholar ] 101. Shi F, Chen B, Cao Q, et al. Semi-Supervised Deep Transfer Learning for Benign-Malignant Diagnosis of Pulmonary Nodules in Chest CT Images. IEEE Trans Med Imaging. 2022;41:771–81. doi: 10.1109/TMI.2021.3123572. [ DOI ] [ PubMed ] [ Google Scholar ] 102. Begum S, Chakraborty D, Sarkar R. Identifying cancer biomarkers from leukemia data using feature selection and supervised learning. 2016 IEEE First International Conference on Control, Measurement and Instrumentation (CMI); Kolkata, India. 2016. pp. 249–53. Available. [ DOI ] [ Google Scholar ] 103. Zou Y, Wang Y, Jiang Z, et al. Breath profile as composite biomarkers for lung cancer diagnosis. Lung Cancer (Auckl) 2021;154:206–13. doi: 10.1016/j.lungcan.2021.01.020. [ DOI ] [ PubMed ] [ Google Scholar ] BMJ Open. 2026 Jun 3. Review Process File Copyright and License information PMC Copyright notice bmjopen-2025-108562.reviewer_comments.pdf (326.9KB, pdf) Open in a new tab Associated Data This section collects any data citations, data availability statements, or supplementary materials included in this article. Supplementary Materials online supplemental file 1 bmjopen-16-6-s001.pdf (215.3KB, pdf) DOI: 10.1136/bmjopen-2025-108562 Data Availability Statement The original data generated by the study will be accessible in a curated data archive at ETH Zurich ( https://www.research-collection.ethz.ch ), the so-called ‘green way’ for open access. Articles from BMJ Open are provided here courtesy of BMJ Publishing Group ACTIONS View on publisher site PDF (1.4 MB) Cite Collections Permalink RESOURCES Similar articles Cited by other articles Links to NCBI Databases Follow NCBI NCBI on X (formerly known as Twitter) NCBI on Facebook NCBI on LinkedIn NCBI on GitHub NCBI RSS feed Connect with NLM NLM on X (formerly known as Twitter) NLM on Facebook NLM on YouTube National Library of Medicine 8600 Rockville Pike Bethesda, MD 20894 Web Policies FOIA HHS Vulnerability Disclosure Help Accessibility Careers NLM NIH HHS USA.gov Back to Top

Related documents

Record · ID 265385 · SHA-256 6ea9d4d2487c1db3
Retrieved via Conceptio: every document is proof-bundled with source, license, and retrieval metadata.
Bring this data into your agent: Connect via MCP or API · 20 free credits to start · no card required
Read the Docs → · View CLI source on GitHub · Conceptio Open Knowledge Archive