Conceptio › Archive › NIST
NIST public full text Public Domain

NIST SP 1800-30: Securing Telehealth Remote Patient Monitoring Ecosystem

Jennifer Cawthra (NIST); Nakia Grayson (NIST); Ronald Pulivarti (NIST); Bronwyn Hodges (MITRE); Jason Kuruvilla (MITRE); Kevin Littlefield (MITRE); Julie Snyder (MITRE); Sue Wang (MITRE); Ryan Williams (MITRE); Kangmin Zheng (MITRE) · National Institute of Standards and Technology (NIST)
NIST · Standards · License: Public Domain
Open Source ↗
nist
Conceptio Open Archive

Analyze & explore related research in Conceptio

Connect this record directly into your research workflow or AI agent. Explore citations across open repositories, query full text, and export structured proof bundles.

NIST SPECIAL PUBLICATION 1800-30

Securing Telehealth Remote Patient Monitoring Ecosystem Includes Executive Summary (A); Approach, Architecture, and Security Characteristics (B); and How-To Guides (C)

Jennifer Cawthra* Nakia Grayson Ronald Pulivarti Bronwyn Hodges Jason Kuruvilla* Kevin Littlefield Julie Snyder Sue Wang Ryan Williams* Kangmin Zheng *Former employee; all work for this publication done while at employer. FINAL This publication is available free of charge from https://doi.org/10.6028/NIST.SP.1800-30 The second draft of this publication is available free of charge from: https://www.nccoe.nist.gov/sites/default/files/legacy-files/rpm-nist-sp1800-30-2nd-draft.pdf

NIST SPECIAL PUBLICATION 1800-30

Securing Telehealth Remote Patient Monitoring Ecosystem Includes Executive Summary (A); Approach, Architecture, and Security Characteristics (B); and How-To Guides (C) Jennifer Cawthra* Nakia Grayson Ronald Pulivarti National Cybersecurity Center of Excellence National Institute of Standards and Technology Bronwyn Hodges Jason Kuruvilla* Kevin Littlefield Julie Snyder Sue Wang Ryan Williams* Kangmin Zheng The MITRE Corporation McLean, Virginia *Former employee; all work for this publication done while at employer. FINAL February 2022

U.S. Department of Commerce Gina M. Raimondo, Secretary

National Institute of Standards and Technology

James K. Olthoff, Performing the non-exclusive functions and duties of the Under Secretary of Commerce for Standards and Technology & Director, National Institute of Standards and Technology

NIST SPECIAL PUBLICATION 1800-30A

Securing Telehealth Remote Patient Monitoring Ecosystem Volume A: Executive Summary

Jennifer Cawthra* Nakia Grayson Ronald Pulivarti

National Cybersecurity Center of Excellence National Institute of Standards and Technology

Bronwyn Hodges Jason Kuruvilla* Kevin Littlefield Sue Wang Ryan Williams* Kangmin Zheng

The MITRE Corporation McLean, Virginia *Former employee; all work for this publication done while at employer.

February 2022 FINAL This publication is available free of charge from https://doi.org/10.6028/NIST.SP.1800-30 The second draft of this publication is available free of charge from: https://www.nccoe.nist.gov/sites/default/files/legacy-files/rpm-nist-sp1800-30-2nd-draft.pdf

Executive Summary

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

Increasingly, healthcare delivery organizations (HDOs) are relying on telehealth and remote patient monitoring (RPM) capabilities to treat patients at home. RPM is convenient and cost-effective, and its adoption rate has increased since the onset of the COVID-19 pandemic. Without adequate privacy and cybersecurity measures, however, unauthorized individuals may expose sensitive data or disrupt patient monitoring services. In collaboration with industry partners, the National Cybersecurity Center of Excellence (NCCoE) built a laboratory environment to demonstrate how HDOs can implement cybersecurity and privacy controls to enhance telehealth RPM resiliency.

CHALLENGE Telehealth RPM solutions deploy components across multiple infrastructure domains that are maintained uniquely. When HDOs deploy RPM solutions, those solutions implement architectures that distribute components across the HDO, telehealth platform providers, and patient homes. Each of these respective environments is managed by different groups of people, often with different sets of resources and technical capabilities. Risks are distributed across the solution architecture, and the methods by which one may mitigate those risks vary in complexity. While HDOs do not have the ability to manage and deploy privacy and cybersecurity controls unilaterally, they retain the responsibility to ensure that appropriate controls and risk mitigation are applied. This practice guide can help your organization:  Identify risks associated with the solution architecture 

Apply the NIST Privacy Framework to broaden understanding of risk

Assure that HDOs partner with appropriate telehealth platform providers to extend privacy and cybersecurity control deployment, management, and efficacy

Consider future technologies that augment data communications safeguards

SOLUTION Technology solutions alone may not be sufficient to maintain privacy and security controls on external environments. This practice guide notes the involvement of people, process, and technology as necessary to implement a holistic risk mitigation strategy. When developing this practice guide, the NCCoE team applied risk assessment approaches to determine where risks may occur and used assessment processes to identify applicable controls. The NCCoE collaborated with healthcare, technology, and telehealth partners to build a distributed RPM solution. The RPM solution implemented controls that safeguard the HDO environment and documented approaches that the telehealth platform provider addresses. Telehealth platform providers assure that RPM components are isolated within the patient home environment. The telehealth platform provider assures end-to-end data security between the patient and the HDO.

NIST SP 1800-30A: Securing Telehealth Remote Patient Monitoring Ecosystem

1

The following is a list of the project’s collaborators: Collaborator

Security Capability or Component Telehealth platform provider, cloud-hosted solution, provides rolebased user access control and data security, performs asset management for the provisioned devices, transmits health information to the platform and connects patients and physicians. Provides identity management, authentication, and access control by using Cisco Firepower, Umbrella, and Stealthwatch.

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

Provides subject matter expertise. Provides anomalies and events and security continuous monitoring by using LogRhythm XDR and LogRhythm NetworkXDR. Provides subject matter expertise. Provides subject matter expertise. Provides identity management, authentication, and access control by leveraging blockchain technology to manage valid endpoints. Provides data-in-transit protection using a layer 2 over layer 3 solution. Risk assessment controls that provide on-premises centralized vulnerability management with multiple scanners, vulnerability prioritization, and risk scores. Provides subject matter expertise. Telehealth platform provider, cloud-hosted solution, provides rolebased user access control and data security, performs asset management for the provisioned devices, transmits health information to the platform, and connects patients and physicians. While the NCCoE used a suite of commercial products to address this challenge, this guide does not endorse these particular products, nor does it guarantee compliance with any regulatory initiatives. Your organization’s information security experts should identify the products that will best integrate with your existing tools and Information Technology (IT) system infrastructure. Your organization can adopt this solution or one that adheres to these guidelines in whole, or you can use this guide as a starting point for tailoring and implementing parts of a solution.

HOW TO USE THIS GUIDE Depending on your role in your organization, you might use this guide in different ways: Business decision makers, including chief information security and technology officers, can use this part of the guide, NIST SP 1800-30a: Executive Summary, to understand the drivers for the guide, the

NIST SP 1800-30A: Securing Telehealth Remote Patient Monitoring Ecosystem

2

cybersecurity challenge we address, our approach to solving this challenge, and how the solution could benefit your organization. Technology, security, and privacy program managers who are concerned with how to identify, understand, assess, and mitigate risk can use NIST SP 1800-30b: Approach, Architecture, and Security Characteristics, which describes what we built and why, including the risk analysis performed and the security/privacy control mappings.

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

IT professionals who want to implement an approach like this can make use of NIST SP 1800-30c: HowTo Guides, which provide specific product installation, configuration, and integration instructions for building the example implementation, allowing you to replicate all or parts of this project.

SHARE YOUR FEEDBACK You can view or download the guide at https://www.nccoe.nist.gov/projects/use-cases/healthit/telehealth. Help the NCCoE make this guide better by sharing your thoughts with us as you read the guide. If you adopt this solution for your own organization, please share your experience and advice with us. We recognize that technical solutions alone will not fully enable the benefits of our solution, so we encourage organizations to share lessons learned and best practices for transforming the processes associated with implementing this guide. To provide comments or to learn more by arranging a demonstration of this example implementation, contact the NCCoE at hit_nccoe@nist.gov.

COLLABORATORS Collaborators participating in this project submitted their capabilities in response to an open call in the Federal Register for all sources of relevant security capabilities from academia and industry (vendors and integrators). Those respondents with relevant capabilities or product components signed a Cooperative Research and Development Agreement (CRADA) to collaborate with NIST in a consortium to build this example solution. Certain commercial entities, equipment, products, or materials may be identified by name or company logo or other insignia in order to acknowledge their participation in this collaboration or to describe an experimental procedure or concept adequately. Such identification is not intended to imply special status or relationship with NIST or recommendation or endorsement by NIST or NCCoE; neither is it intended to imply that the entities, equipment, products, or materials are necessarily the best available for the purpose.

NIST SP 1800-30A: Securing Telehealth Remote Patient Monitoring Ecosystem

3

NIST SPECIAL PUBLICATION 1800-30B

Securing Telehealth Remote Patient Monitoring Ecosystem Volume B: Approach, Architecture, and Security Characteristics

Jennifer Cawthra* Nakia Grayson Ronald Pulivarti

National Cybersecurity Center of Excellence National Institute of Standards and Technology

Bronwyn Hodges Jason Kuruvilla* Kevin Littlefield Julie Snyder Sue Wang Ryan Williams* Kangmin Zheng

The MITRE Corporation McLean, Virginia *Former employee; all work for this publication done while at employer.

February 2022 FINAL This publication is available free of charge from https://doi.org/10.6028/NIST.SP.1800-30 The second draft of this publication is available free of charge from: https://www.nccoe.nist.gov/sites/default/files/legacy-files/rpm-nist-sp1800-30-2nd-draft.pdf

DISCLAIMER

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

Certain commercial entities, equipment, products, or materials may be identified by name or company logo or other insignia in order to acknowledge their participation in this collaboration or to describe an experimental procedure or concept adequately. Such identification is not intended to imply special status or relationship with NIST or recommendation or endorsement by NIST or NCCoE; neither is it intended to imply that the entities, equipment, products, or materials are necessarily the best available for the purpose.

National Institute of Standards and Technology Special Publication 1800-30B, Natl. Inst. Stand. Technol. Spec. Publ. 1800-30B, 202 pages, (February 2022), CODEN: NSPUE2

FEEDBACK As a private-public partnership, we are always seeking feedback on our practice guides. We are particularly interested in seeing how businesses apply NCCoE reference designs in the real world. If you have implemented the reference design, or have questions about applying it in your environment, please email us at hit_nccoe@nist.gov. All comments are subject to release under the Freedom of Information Act.

National Cybersecurity Center of Excellence National Institute of Standards and Technology 100 Bureau Drive Mailstop 2002 Gaithersburg, MD 20899 Email: nccoe@nist.gov

NIST SP 1800-30B: Securing Telehealth Remote Patient Monitoring Ecosystem

ii

NATIONAL CYBERSECURITY CENTER OF EXCELLENCE

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

The National Cybersecurity Center of Excellence (NCCoE), a part of the National Institute of Standards and Technology (NIST), is a collaborative hub where industry organizations, government agencies, and academic institutions work together to address businesses’ most pressing cybersecurity issues. This public-private partnership enables the creation of practical cybersecurity solutions for specific industries, as well as for broad, cross-sector technology challenges. Through consortia under Cooperative Research and Development Agreements (CRADAs), including technology partners—from Fortune 50 market leaders to smaller companies specializing in information technology security—the NCCoE applies standards and best practices to develop modular, adaptable example cybersecurity solutions using commercially available technology. The NCCoE documents these example solutions in the NIST Special Publication 1800 series, which maps capabilities to the NIST Cybersecurity Framework and details the steps needed for another entity to re-create the example solution. The NCCoE was established in 2012 by NIST in partnership with the State of Maryland and Montgomery County, Maryland. To learn more about the NCCoE, visit https://www.nccoe.nist.gov/. To learn more about NIST, visit https://www.nist.gov.

NIST CYBERSECURITY PRACTICE GUIDES NIST Cybersecurity Practice Guides (Special Publication 1800 series) target specific cybersecurity challenges in the public and private sectors. They are practical, user-friendly guides that facilitate the adoption of standards-based approaches to cybersecurity. They show members of the information security community how to implement example solutions that help them align with relevant standards and best practices and provide users with the lists of materials, configuration files, and other information they need to implement a similar approach. The documents in this series describe example implementations of cybersecurity practices that businesses and other organizations may voluntarily adopt. These documents do not describe regulations or mandatory practices nor do they carry statutory authority.

ABSTRACT Increasingly, healthcare delivery organizations (HDOs) are relying on telehealth and remote patient monitoring (RPM) capabilities to treat patients at home. RPM is convenient and cost-effective, and its adoption rate has increased. However, without adequate privacy and cybersecurity measures, unauthorized individuals may expose sensitive data or disrupt patient monitoring services. RPM solutions engage multiple actors as participants in patients’ clinical care. These actors include HDOs, telehealth platform providers, and the patients themselves. Each participant uses, manages, and maintains different technology components within an interconnected ecosystem, and each is

NIST SP 1800-30B: Securing Telehealth Remote Patient Monitoring Ecosystem

iii

responsible for safeguarding their piece against unique threats and risks associated with RPM technologies.

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

This practice guide assumes that the HDO engages with a telehealth platform provider that is a separate entity from the HDO and patient. The telehealth platform provider manages a distinct infrastructure, applications, and set of services. The telehealth platform provider coordinates with the HDO to provision, configure, and deploy the RPM components to the patient home and assures secure communication between the patient and clinician. The NCCoE analyzed RPM ecosystem risk factors by applying methods described in the NIST Risk Management Framework. The NCCoE also leveraged the NIST Cybersecurity Framework, NIST Privacy Framework, and other relevant standards to identify measures to safeguard the ecosystem. In collaboration with healthcare, technology, and telehealth partners, the NCCoE built an RPM ecosystem in a laboratory environment to explore methods to improve the cybersecurity of an RPM. Technology solutions alone may not be sufficient to maintain privacy and security controls on external environments. This practice guide notes the application of people, process, and technology as necessary to implement a holistic risk mitigation strategy. This practice guide’s benefits include helping organizations assure the confidentiality, integrity, and availability of an RPM solution, enhancing patient privacy and limiting HDO risk when implementing an RPM solution.

KEYWORDS access control; authentication; authorization; behavioral analytics; cloud storage; data privacy; data security; encryption; HDO; healthcare; healthcare delivery organization; remote patient monitoring; RPM; telehealth; zero trust

ACKNOWLEDGMENTS We are grateful to the following individuals for their generous contributions of expertise and time. Name

Organization

Alex Mohseni

Accuhealth

Stephen Samson

Accuhealth

Brian Butler

Cisco

Matthew Hyatt

Cisco

NIST SP 1800-30B: Securing Telehealth Remote Patient Monitoring Ecosystem

iv

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

Name

Organization

Kevin McFadden

Cisco

Peter Romness

Cisco

Brad Hoehn

Huntington Ingalls Industries-Mission Driven Innovative Solutions (HII-MDIS)

David Lemire

Huntington Ingalls Industries-Mission Driven Innovative Solutions (HII-MDIS)

Steven Dean

Inova Health System

Zach Furness

Inova Health System

James Carder

LogRhythm

Brian Coulson

LogRhythm

Steven Forsyth

LogRhythm

Jake Haldeman

LogRhythm

Andrew Hollister

LogRhythm

Zack Hollister

LogRhythm

Dan Kaiser

LogRhythm

Sally Vincent

LogRhythm

Vidya Murthy

MedCrypt

Axel Wirth

MedCrypt

Stephanie Domas

MedSec

NIST SP 1800-30B: Securing Telehealth Remote Patient Monitoring Ecosystem

v

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

Name

Organization

Garrett Sipple

MedSec

Nancy Correll

The MITRE Corporation

Spike Dog

The MITRE Corporation

Robin Drake

The MITRE Corporation

Sallie Edwards

The MITRE Corporation

Donald Faatz

The MITRE Corporation

Nedu Irrechukwu

The MITRE Corporation

Karri Meldorf

The MITRE Corporation

Stuart Shapiro

The MITRE Corporation

Barbara Cuthill

NIST

Jeffrey Marron

NIST

Paul Watrobski

NIST

John Dwyier

Onclave Networks, Inc. (Onclave)

Chris Grodzickyj

Onclave

Marianne Meins

Onclave

Dennis Perry

Onclave

Christina Phillips

Onclave

Robert Schwendinger

Onclave

NIST SP 1800-30B: Securing Telehealth Remote Patient Monitoring Ecosystem

vi

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

Name

Organization

James Taylor

Onclave

Chris Jensen

Tenable

Joshua Moll

Tenable

Jeremiah Stallcup

Tenable

Rebecca Herold

The Privacy Professor Consultancy

Julio C. Cespedes

The University of Mississippi Medical Center

Saurabh Chandra

The University of Mississippi Medical Center

Donald Clark

The University of Mississippi Medical Center

Alan Jones

The University of Mississippi Medical Center

Kristy Simms

The University of Mississippi Medical Center

Richard Summers

The University of Mississippi Medical Center

Steve Waite

The University of Mississippi Medical Center

Dele Atunrase

Vivify Health

Aaron Gatz

Vivify Health

Michael Hawkins

Vivify Health

Robin Hill

Vivify Health

Dennis Leonard

Vivify Health

David Norman

Vivify Health

NIST SP 1800-30B: Securing Telehealth Remote Patient Monitoring Ecosystem

vii

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

Name

Organization

Bill Paschall

Vivify Health

Eric Rock

Vivify Health

Alan Stryker

Vivify Health

Dave Sutherland

Vivify Health

Michael Tayler

Vivify Health

The Technology Partners/Collaborators who participated in this build submitted their capabilities in response to a notice in the Federal Register. Respondents with relevant capabilities or product components were invited to sign a Cooperative Research and Development Agreement (CRADA) with NIST, allowing them to participate in a consortium to build this example solution. We worked with: Technology Partner/Collaborator

Build Involvement

Accuhealth

Accuhealth Evelyn

Cisco

Cisco Firepower Version 6.3.0 Cisco Umbrella Cisco Stealthwatch Version 7.0.0

Inova Health System

subject matter expertise

LogRhythm

LogRhythm XDR Version 7.4.9 LogRhythm NetworkXDR Version 4.0.2

MedCrypt

subject matter expertise

MedSec

subject matter expertise

Onclave

Onclave Zero Trust Platform Version 1.1.0

NIST SP 1800-30B: Securing Telehealth Remote Patient Monitoring Ecosystem

viii

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

Technology Partner/Collaborator

Build Involvement

Tenable

Tenable.sc Vulnerability Management Version 5.13.0 with Nessus

The University of Mississippi Medical Center

subject matter expertise

Vivify Health

Vivify Pathways Home Vivify Pathways Care Team Portal

DOCUMENT CONVENTIONS The terms “shall” and “shall not” indicate requirements to be followed strictly to conform to the publication and from which no deviation is permitted. The terms “should” and “should not” indicate that among several possibilities, one is recommended as particularly suitable without mentioning or excluding others, or that a certain course of action is preferred but not necessarily required, or that (in the negative form) a certain possibility or course of action is discouraged but not prohibited. The terms “may” and “need not” indicate a course of action permissible within the limits of the publication. The terms “can” and “cannot” indicate a possibility and capability, whether material, physical, or causal.

PATENT DISCLOSURE NOTICE NOTICE: The Information Technology Laboratory (ITL) has requested that holders of patent claims whose use may be required for compliance with the guidance or requirements of this publication disclose such patent claims to ITL. However, holders of patents are not obligated to respond to ITL calls for patents and ITL has not undertaken a patent search in order to identify which, if any, patents may apply to this publication. As of the date of publication and following call(s) for the identification of patent claims whose use may be required for compliance with the guidance or requirements of this publication, no such patent claims have been identified to ITL. No representation is made or implied by ITL that licenses are not required to avoid patent infringement in the use of this publication.

NIST SP 1800-30B: Securing Telehealth Remote Patient Monitoring Ecosystem

ix

Contents 1 Summary ............................................................................................ 1 1.1

Challenge ....................................................................................................................... 2

1.2

Solution.......................................................................................................................... 3

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

2 How to Use This Guide ........................................................................ 3 2.1

Typographic Conventions .............................................................................................. 4

3 Approach ............................................................................................ 5 3.1

Audience ........................................................................................................................ 6

3.2

Scope ............................................................................................................................. 6

3.3

Assumptions .................................................................................................................. 6

3.4

Risk Assessment ............................................................................................................ 7 3.4.1

Threats .......................................................................................................................... 8

3.4.2

Vulnerabilities ............................................................................................................... 9

3.4.3

Problematic Data Actions for Privacy ........................................................................... 9

3.4.4

Risk .............................................................................................................................. 11

3.4.5

Mitigating Risk ............................................................................................................ 14

3.5

Security Control Map................................................................................................... 14

3.6

Technologies ................................................................................................................ 33

4 Architecture ...................................................................................... 38 4.1

Layering the Architecture ............................................................................................ 40

4.2

High-Level Architecture Communications Pathways .................................................. 41 4.2.1

Cellular Data Pathways ............................................................................................... 41

4.2.2

Broadband Pathways .................................................................................................. 42

4.3

Data and Process Flows ............................................................................................... 43

4.4

Security Capabilities .................................................................................................... 46 4.4.1

Telehealth Platform Provider...................................................................................... 47

4.4.2

Identity Management, Authentication, and Access Control ......................................48

4.4.3

Data Security ............................................................................................................... 50

NIST SP 1800-30B: Securing Telehealth Remote Patient Monitoring Ecosystem

x

4.4.4

4.5

Anomalies and Events and Security Continuous Monitoring .....................................50

Final Architecture ........................................................................................................ 50

5 Security and Privacy Characteristic Analysis ...................................... 51

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

5.1

Assumptions and Limitations ...................................................................................... 52

5.2

Pervasive Controls ....................................................................................................... 52

5.3

Telehealth Platform Providers .................................................................................... 53

5.4

Risk Assessment (ID.RA and ID.RA-P) .......................................................................... 54

5.5

Identity Management, Authentication, and Access Control (PR.AC and PR.AC-P) Protective Technology (PR.PT-P) ................................................................................. 54

5.6

Data Security (PR.DS and PR.DS-P) .............................................................................. 56

5.7

Anomalies and Events, Security Continuous Monitoring (DE.AE, DE.CM), and Data Processing Management (CT.DM-P) ........................................................................... 56

6 Functional Evaluation........................................................................ 57 6.1

RPM Functional Test Plan ............................................................................................ 57 6.1.1

RPM Functional Evaluation ......................................................................................... 57

6.1.2

Test Case: RPM-1 ........................................................................................................ 59

6.1.3

Test Case: RPM-2 ........................................................................................................ 61

6.1.4

Test Case: RPM-3 ........................................................................................................ 61

6.1.5

Test Case: RPM-4 ........................................................................................................ 63

6.1.6

Test Case: RPM-5 ........................................................................................................ 66

6.1.7

Test Case: RPM-6 ........................................................................................................ 68

6.1.8

Test Case: RPM-7 ........................................................................................................ 70

6.1.9

Test Case: RPM-8 ........................................................................................................ 71

6.1.10 Test Case: RPM-9 ........................................................................................................ 75 6.1.11 Test Case: RPM-10 ...................................................................................................... 76 6.1.12 Test Case: RPM-11 ...................................................................................................... 78

7 Future Build Considerations .............................................................. 81 Appendix A List of Acronyms ................................................................. 82 Appendix B References ......................................................................... 84

NIST SP 1800-30B: Securing Telehealth Remote Patient Monitoring Ecosystem

xi

Appendix C Threats and Risks ............................................................... 88 C-1 Discussion on the Risk Management Framework .......................................................... 88 C-2 Information and Information System Categorization .................................................... 89 C-3 Risk Context .................................................................................................................... 90 C-4 Threats............................................................................................................................ 91 This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

C-5 Threat Sources ............................................................................................................... 96 C-5.1 Business Processes ......................................................................................................... 99

C-6 Vulnerabilities .............................................................................................................. 101 C-7 Threat Modeling ........................................................................................................... 103 C-7.1 Modeling Threats to the Patient Home ........................................................................ 103 C-7.2 Linking Threats to Adverse Actions .............................................................................. 116

Appendix A Problematic Data Actions and Risks .................................. 119 D-1 Privacy Risk Assessment Methodology........................................................................ 119 D-2 Problematic Data Actions and Mitigations .................................................................. 121 D-2.1 Privacy Risk 1: Storage and movement of data create multiple points of potential exposure after data are collected from the patient .................................................122 D-2.2 Privacy Risk 2: Biometric device types can indicate patient health problems that individuals would prefer not to disclose beyond their healthcare provider ............123 D-2.3 Privacy Risk 3: Incorrect data capture of readings by devices may impact quality of patient care ............................................................................................................... 124 D-2.4 Privacy Risk 4: Aggregated data may expose patient information ..............................125 D-2.5 Privacy Risk 5: Exposure of patient information through multiple providers of system components increases the likelihood of exposure of patient data to unintended recipients .................................................................................................................. 126

D-3 Additional Program Mitigations Applicable Across Various Data Actions .................. 128

Appendix E Benefits of IoT Device Cybersecurity Requirements ............ 129 E-1 Device Capabilities Mapping ........................................................................................ 130 E-2 Device Capabilities Supporting Functional Evaluations ............................................... 170

Appendix F Applying the OSI Model in Understanding Zero Trust Architecture ........................................................................................ 201

NIST SP 1800-30B: Securing Telehealth Remote Patient Monitoring Ecosystem

xii

List of Figures Figure 4-1 RPM Architecture .............................................................................................................. 39 Figure 4-2 Architecture Layers ............................................................................................................ 41 Figure 4-3 RPM Communications Paths .............................................................................................. 43 This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

Figure 4-4 RPM Dataflow Option 1 ..................................................................................................... 45 Figure 4-5 RPM Dataflow Option 2 ..................................................................................................... 46 Figure 4-6 Network Segmentation and VLAN Within the RPM Lab...................................................... 49 Figure 4-7 Final Architecture .............................................................................................................. 51 Figure C-1 Risk Management Framework [35]…………………………………………………………………………………..89 Figure D-1 Privacy View of RPM Solution Dataflow .......................................................................... 121 Figure F-1 Enclave Gateway Model [25] ........................................................................................... 202

List of Tables Table 3-1 Threat Taxonomy.................................................................................................................. 8 Table 3-2 Problematic Data Action Taxonomy .................................................................................... 10 Table 3-3 Cybersecurity Risk Taxonomy ............................................................................................. 11 Table 3-4 Privacy Risk Taxonomy ....................................................................................................... 12 Table 3-5 Security Characteristics and Controls Mapping–NIST Cybersecurity Framework .................. 15 Table 3-6 Privacy Characteristics and Controls Mapping–NIST Privacy Framework ............................. 30 Table 3-7 Products and Technologies ................................................................................................. 35 Table 6-1 Functional Evaluation Requirements................................................................................... 58 Table C-1 Information Types and Categorizations ............................................................................... 90 Table C-2 Assessment Scale: Likelihood of Threat Event Initiation ...................................................... 92 Table C-3 Threats Applied to the Patient Home .................................................................................. 92 Table C-4 Threats Applied to the Telehealth Platform Provider .......................................................... 94 Table C-5 Threats Applied to the HDO ................................................................................................ 95 Table C-6 Taxonomy of Threat Sources............................................................................................... 96

NIST SP 1800-30B: Securing Telehealth Remote Patient Monitoring Ecosystem

ii

Table C-7 RPM Functions and Processes ............................................................................................. 99 Table C-8 Vulnerability Taxonomy .................................................................................................... 102 Table C-9 Components in the Patient Home Environment ................................................................ 104 Table C-10 Biometric Device Subcomponent Breakdown.................................................................. 106 Table C-11 Interface Device Subcomponent Breakdown ................................................................... 108 This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

Table C-12 Laptop Subcomponent Breakdown ................................................................................. 111 Table C-13 Desktop Subcomponent Breakdown ............................................................................... 114 Table C-14 Threat Event to Adverse Action Mapping ........................................................................ 117 Table E-1 Mapping of Device Cybersecurity Capabilities and Nontechnical Supporting Capabilities to NIST Cybersecurity Framework Subcategories of the RPM Project ................................................... 131 Table E-2 Device Cybersecurity Capabilities and Nontechnical Supporting Capabilities that Map to Each of the Functional Test Cases…………………………………………………………………………………………………………… 171

NIST SP 1800-30B: Securing Telehealth Remote Patient Monitoring Ecosystem

iii

1 Summary

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

This practice guide demonstrates how healthcare delivery organizations (HDOs) can implement cybersecurity and privacy controls to enhance the resiliency of telehealth services. In collaboration with industry partners, the National Cybersecurity Center of Excellence (NCCoE) at the National Institute of Standards and Technology (NIST) built a laboratory environment to simulate the telehealth ecosystem and enable remote patient monitoring (RPM) services for patients. RPM is convenient, cost-effective, and growing, but it comes with security and privacy risks. Patient monitoring systems are often found in controlled healthcare facility environments. RPM is different in that monitoring equipment is deployed in the patient’s home, which may not offer the same level of cybersecurity or physical security control to prevent misuse or compromise. Without privacy or cybersecurity controls in place within the RPM ecosystem, patient data and the ability to communicate with the care providers may be compromised. This practice guide explores a situation in which a care provider prescribes deploying an RPM device to the patient home. The RPM device captures biometric data on regular intervals, conveys the data to the clinical care team, and allows patient-clinician communication without the patient making an in-person visit to the HDO. RPM enables care based on the patient’s needs, regardless of geographic constraints. Capturing biometric data at regular intervals allows clinicians to have broader insight into a patient’s condition. With larger data sets, clinicians can monitor the patient’s condition and make diagnosis and treatment decisions with more robust information. RPM solutions allow audio and video communication in addition to utilizing biometric data, and they support the patient-clinician relationship. Implementing an RPM ecosystem involves multiple parties and environments. In developing the reference architecture for this practice guide, the NCCoE considered components that would be deployed in three distinct domains that encompass the RPM ecosystem: the patient home environment, the telehealth platform provider, and the HDO. The project team engaged with a telehealth platform provider that leveraged cloud services and facilitated audio- and videoconferencing between the patient home and the HDO. The telehealth platform provider provisioned and managed biometric devices that were deployed in the patient home, and routed data and communication between the patient home and the HDO. The NCCoE built a laboratory environment to simulate the telehealth ecosystem, performed a risk assessment, and developed an example implementation that demonstrates how HDOs can use standards-based, commercially available cybersecurity technologies and collaborate with telehealth platform providers to assure privacy and security biometric devices that are deployed to the patient home. For ease of use, the following paragraphs provide a short description of each section of this volume. Section 1, Summary, presents: the challenge addressed by the NCCoE project with an in-depth look at our approach, the architecture, and the security characteristics we used; the solution demonstrated to

NIST SP 1800-30B: Securing Telehealth Remote Patient Monitoring Ecosystem

1

address the challenge; benefits of the solution; and the collaborators who participated in building, demonstrating, and documenting the solution. Section 2, How to Use This Guide, explains how business decision makers, program managers, information technology (IT) professionals (e.g., systems administrators), and biometric engineers might use each volume of the guide. This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

Section 3, Approach, offers a detailed treatment of the scope of the project, the risk assessment that informed platform development, and the technologies and components that industry collaborators gave us to enable platform development. Section 4, Architecture, specifies the components within the RPM ecosystem from business, security, and infrastructure perspectives and details how data and processes flow throughout the ecosystem. This section also describes the security capabilities and controls referenced in the NIST Cybersecurity Framework through tools provided by the project collaborators. Section 5, Security and Privacy Characteristic Analysis, provides details about the tools and techniques used to perform risk assessments pertaining to RPM. Section 6, Functional Evaluation, summarizes the test sequences employed to demonstrate security platform services, the NIST Cybersecurity Framework Functions to which each test sequence is relevant, and the NIST Special Publication (SP) 800-53 Revision 5 controls demonstrated in the example implementation. Section 7, Future Build Considerations, is a brief treatment of other applications that NIST might explore in the future to further protect a telehealth environment. The appendices provide acronym translations, references, a deeper dive into the threats and risks associated with RPM, the review of the NIST Privacy Risk Assessment Methodology (PRAM), and a list of additional informative security references cited in the framework.

1.1 Challenge Telehealth RPM solutions deploy components across multiple infrastructure domains that are maintained uniquely. When HDOs deploy RPM solutions, those solutions implement architectures that distribute components across the HDO, telehealth platform providers, and patient homes. Each of these respective environments is managed by different groups of people, often with different sets of resources and technical capabilities. Risks are distributed across the solution architecture, and the methods by which one may mitigate those risks vary in complexity. While HDOs do not have the ability to manage and deploy privacy and cybersecurity controls unilaterally, they retain the responsibility to ensure that appropriate controls and risk mitigation are applied.

NIST SP 1800-30B: Securing Telehealth Remote Patient Monitoring Ecosystem

2

This practice guide can help your organization:  Identify risks associated with the solution architecture

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

Apply the NIST Privacy Framework to broaden understanding of risk

Assure that HDOs partner with appropriate telehealth platform providers to extend privacy and cybersecurity control deployment, management, and efficacy

Consider future technologies that augment data communications safeguards

1.2 Solution Technology solutions alone may not be sufficient to maintain privacy and security controls on external environments. This practice guide notes the involvement of people, process, and technology as necessary to implement a holistic risk mitigation strategy. When developing this practice guide, the NCCoE team applied risk assessment approaches to determine where risks may occur and used assessment processes to identify applicable controls. The NCCoE collaborated with healthcare, technology, and telehealth partners to build a distributed RPM solution. The RPM solution implemented controls that safeguard the HDO environment and documented approaches that the telehealth platform provider addresses. Telehealth platform providers assure that RPM components are isolated within the patient home environment. The telehealth platform provider assures end-to-end data security between the patient and the HDO.

2 How to Use This Guide This NIST Cybersecurity Practice Guide demonstrates a standards-based reference design and provides users with the information they need to replicate an RPM environment. This reference design is modular and can be deployed in whole or in part. This guide contains three volumes: 

NIST SP 1800-30A: Executive Summary

NIST SP 1800-30B: Approach, Architecture, and Security Characteristics–what we built and why (you are here)

NIST SP 1800-30C: How-To Guides–instructions for building the example solution

Depending on your role in your organization, you might use this guide in different ways: Business decision makers, including chief security and technology officers, will be interested in the Executive Summary, NIST SP 1800-30A, which describes the following topics:

NIST SP 1800-30B: Securing Telehealth Remote Patient Monitoring Ecosystem

3

challenges that enterprises face in securing the RPM ecosystem

example solution built at the NCCoE

benefits of adopting the example solution

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

Technology or security program managers who are concerned with how to identify, understand, assess, and mitigate risk will be interested in this part of the guide, NIST SP 1800-30B, which describes what we did and why. The following sections will be of particular interest: 

Section 3.4, Risk Assessment, provides a description of the risk analysis we performed

Section 3.5, Security Control Map, maps the security characteristics of this example solution to cybersecurity standards and best practices

You might share the Executive Summary, NIST SP 1800-30A, with your leadership team members to help them understand the importance of adopting standards-based commercially available technologies that can help secure the RPM ecosystem. IT professionals who want to implement an approach like this will find the whole practice guide useful. You can use the how-to portion of the guide, NIST SP 1800-30C, to replicate all or parts of the build created in our lab. The how-to portion of the guide provides specific product installation, configuration, and integration instructions for implementing the example solution. We do not re-create the product manufacturers’ documentation, which is generally widely available. Rather, we show how we incorporated the products together in our environment to create an example solution. This guide assumes that IT professionals have experience implementing security products within the enterprise. While we have used a suite of commercial products to address this challenge, this guide does not endorse these particular products. Your organization can adopt this solution or one that adheres to these guidelines in whole, or you can use this guide as a starting point for tailoring and implementing parts of the NCCoE’s risk assessment and deployment of a defense-in-depth strategy in a distributed RPM solution. Your organization’s security experts should identify the products that will best integrate with your existing tools and IT system infrastructure. We hope that you will seek products that are congruent with applicable standards and best practices. Section 3.6, Technologies, lists the products we used and maps them to the cybersecurity controls provided by this reference solution. A NIST Cybersecurity Practice Guide does not describe “the” solution but a possible solution. Comments, suggestions, and success stories will improve subsequent versions of this guide. Please contribute your thoughts to hit_nccoe@nist.gov. Acronyms used in figures are in the List of Acronyms appendix.

2.1 Typographic Conventions The following table presents typographic conventions used in this volume.

NIST SP 1800-30B: Securing Telehealth Remote Patient Monitoring Ecosystem

4

Typeface/Symbol

Meaning

Example

Italics

file names and path names; references to documents that are not hyperlinks; new terms; and placeholders names of menus, options, command buttons, and fields command-line input, onscreen computer output, sample code examples, and status codes command-line user input contrasted with computer output link to other parts of the document, a web URL, or an email address

For language use and style guidance, see the NCCoE Style Guide.

Bold This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

Monospace

Monospace Bold

blue text

Choose File > Edit. mkdir

service sshd start

All publications from NIST’s NCCoE are available at https://www.nccoe.nist.gov.

3 Approach RPM is a telehealth use case wherein healthcare providers can use internet-based technologies to track biometric data from the patient’s home. Patients may have chronic or recurring health conditions that require regular clinical monitoring; however, in-person visitation may be impractical or undesirable. Technology enables capturing biometric and patient-generated data, having those data relayed to systems that clinicians may use to evaluate a patient, and bidirectional communication of the data between the patient and clinician. RPM may be an appropriate means for performing healthcare in pandemic scenarios or to address patients who may live in parts of the country where healthcare settings or practitioners are scarce. The NCCoE collaborated with a healthcare Community of Interest (COI) that included technology and cybersecurity vendors, healthcare cybersecurity subject matter experts, and healthcare systems to identify RPM use cases, data workflows, ecosystem actor, and general deployment architecture. Further, with the assistance of the COI and external cybersecurity subject matter experts, a risk assessment was performed and reviewed, thereby confirming the measures and outcomes that were determined from the risk assessment activity. Additionally, this project reviewed NIST SP 800-171 Rev. 2, Protecting Controlled Unclassified Information in Nonfederal Systems and Organizations [1], as well as NIST SP 800-181 Rev. 1, Workforce Framework for Cybersecurity (NICE Framework) [2], for further guidance. These documents serve as

NIST SP 1800-30B: Securing Telehealth Remote Patient Monitoring Ecosystem

5

background for this project, with primary emphasis on the NIST Cybersecurity Framework [3], the NIST Risk Management Framework [4], and the NIST Privacy Framework [5].

3.1 Audience

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

This guide is intended for professionals implementing an RPM ecosystem for HDOs that use third-party telehealth platform providers. This guide examines scenarios where HDOs partner with a third-party telehealth platform provider where that telehealth platform provider manages devices that are used by the patient in their home setting. The telehealth platform provider implements technology that collects and makes biometric data available to clinicians, thus allowing the HDO to focus on patient care delivery. Approaches and controls focus on securing end-to-end communications and safeguarding assets and data that reside at HDO facilities; and they also discuss measures that HDOs and telehealth platform providers should implement in the patient home.

3.2 Scope This RPM practice guide focuses on scenarios where patients with chronic or recurring conditions have biometric devices in their home that enable clinicians to regularly receive biometric data. The scope of this practice guide is limited to remote patient monitoring and does not include remote care. Patients and clinicians may use audio- and videoconferencing. The solution includes a third-party telehealth platform provider that provisions and manages biometric devices and provides means of communication.

3.3 Assumptions This practice guide makes the following assumptions: 

RPM architecture includes deploying components to three distinct domains: the patient home, the telehealth platform provider, and the HDO.

HDOs are regulated entities and must comply with federal, state, and local laws and regulations. In complying with laws and regulations, HDOs have implemented adequate privacy and security programs that include activities to address risk to both the organization and individuals when deploying an RPM architecture. Controls that have been implemented in accordance with laws and regulations provide an enterprise scope that this document refers to as pervasive controls.

The telehealth platform provider maintains an adequate privacy and security control environment.

The telehealth platform provider manages the configuration of patient home-deployed equipment.

The patient home may have different communications options such as cellular data connectivity or broadband internet.

NIST SP 1800-30B: Securing Telehealth Remote Patient Monitoring Ecosystem

6

RPM solutions emphasize collaboration. An RPM program’s efficacy depends on the patient, the telehealth platform provider, and the HDO to participate in the program and apply adequate privacy and security practices. The HDO does not define the control environments for the telehealth platform provider or the patient home. Each participant needs sufficient awareness and exercises appropriate control over components that operate in their domain.

Patient engagement activities provide the patient a clear understanding of privacy practices and expectations that address the specifics of the RPM architecture.

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

For this practice guide, telehealth platform providers deployed biometric devices with cellular data capabilities. Additionally, this practice guide implemented a solution for biometric devices that used patient home Wi-Fi communications.

3.4 Risk Assessment NIST SP 800-30 Revision 1, Guide for Conducting Risk Assessments, states that risk is “a measure of the extent to which an entity is threatened by a potential circumstance or event, and typically a function of: (i) the adverse impacts that would arise if the circumstance or event occurs; and (ii) the likelihood of occurrence”. The guide further defines risk assessment as “the process of identifying, estimating, and prioritizing risks to organizational operations (including mission, functions, image, reputation), organizational assets, individuals, other organizations, and the Nation, resulting from the operation of an information system. Part of risk management incorporates threat and vulnerability analyses, and considers mitigations provided by security controls planned or in place”. The NCCoE recommends that any discussion of risk management, particularly at the enterprise level, begins with a comprehensive review of NIST SP 800-37 Revision 2, Risk Management Framework for Information Systems and Organizations. The Risk Management Framework (RMF) guidance, as a whole, proved to be invaluable in giving us a baseline to assess risks, from which we developed the project, the security characteristics of the build, and this guide. In this practice guide, the NCCoE implements multiple approaches in assessing risk. An RPM environment is composed of multiple domains, with different constituents managing each domain. When analyzing risk, this practice guide contextualizes that risk and selects mitigating controls by disrupting threats. A description of how this practice guide addresses these concepts is in Appendix C, Threats and Risks. The risk assessments included in Appendix C represent how the practice guide examines risks. Organizations may find that the threats, vulnerabilities, and risks that they observe may differ from this practice guide’s assessment. The risk assessments in this practice guide serve as examples that may catalyze how organizations perform their own risk assessments.

NIST SP 1800-30B: Securing Telehealth Remote Patient Monitoring Ecosystem

7

3.4.1

Threats

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

NIST SP 800-30 Revision 1 defines a threat as “[a]ny circumstance or event with the potential to adversely impact organizational operations and assets, individuals, other organizations, or the Nation through an information system via unauthorized access, destruction, disclosure, or modification of information, and/or denial of service”. Threats are actions that may compromise a system’s confidentiality, integrity, or availability [6]. Table 3-1 describes threats that have been evaluated for this project. Threats evolve, and an organization needs to perform its own analysis when evaluating threats and risks that the organization faces. Table 3-1 below is a sample threat taxonomy as it applies across the entire RPM ecosystem. The threat taxonomy uses: a confidentiality (C), integrity (I), and availability (A) categorization; the threat event considered; and a description of the threat event. While the threat taxonomy provides a landscape view of threats, organizations may want to perform threat modeling to determine contextual application of threats. Appendix C, Threats and Risks, describes concepts on how to examine contextualized threats. Table 3-1 Threat Taxonomy C, I, A

Threat Event

Description

C

phishing

Phishing attacks are a form of social engineering, where the attacker presents themselves as a trusted party to gain the confidence of the victim.

I, A

malicious software

Malicious software (malware) is unauthorized code that may be introduced to a system. It performs unintended actions that may disrupt normal system function. Malware may masquerade as desirable apps or applications.

I, A

command and control

Command and control attacks may begin with deployment of malware. Malware may allow a system to be operated remotely by unauthorized entities. Should a system fall victim to a command-and-control attack, that system may then be used as a pivot point to attack other components, either within the organization’s infrastructure or as a point where attacks may be launched against other organizations.

A

ransomware

Ransomware is a form of malware that disrupts access to system resources. A typical form of ransomware involves the malware employing encryption that disables a legitimate system user from accessing files. Ransomware attacks generally involve a demand for

NIST SP 1800-30B: Securing Telehealth Remote Patient Monitoring Ecosystem

8

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

C, I, A

Threat Event

Description payment to restore files. Payment does not ensure that the attacker will decrypt files, however.

C

credential escalation

Credential escalation attacks seek to take user account capabilities and extend those to a privileged level of capability.

I, A

operating system or application disruption

The operating system or application may be adversely affected by malicious actors who successfully implement malware on the target device. Data may be altered or the device or application may not function properly.

C

data exfiltration

Malicious actors may be able to retrieve sensitive information from vulnerable devices. Malware may be used for this purpose.

A

denial of service attack

Flooding network connections with high-volume traffic to disrupt communication in patient home, between home and telehealth platform, or between telehealth platform provider and HDO. This type of attack could also be used to damage a device, e.g., through accelerated battery depletion.

I

transmitted data manipulation

Unauthorized individuals may intercept and alter data transmissions.

3.4.2

Vulnerabilities

This practice guide uses a customized application for identifying vulnerabilities, which aggregates vulnerabilities identified in NIST SP 800-30 Revision 1. As noted in this special publication, a vulnerability is a deficiency or weakness that a threat source may exploit, resulting in a threat event. The document further describes how vulnerabilities may exist in a broader context, i.e., that they may be found in organizational governance structures, external relationships, and mission/business processes. The table in Section C-6 of Appendix C, Threats and Risks, enumerates those vulnerabilities by using a holistic approach and represents those vulnerabilities that this project identified and for which it offers guidance.

3.4.3

Problematic Data Actions for Privacy

This build considered operational activities of the example solution that interact with patient data during RPM processes (“data actions”) and identified those that potentially cause problems to individuals.

NIST SP 1800-30B: Securing Telehealth Remote Patient Monitoring Ecosystem

9

The NIST Privacy Framework defines a problematic data action as “a data action that could cause an adverse effect for individuals” [5]. Problematic data actions can result in privacy risk to individuals and prevent an organization from developing a solution that meets the privacy engineering objectives of:   This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

predictability: enabling reliable assumptions by individuals, owners, and operators about data and their processing by a system, product, or service manageability: providing the capability for granular administration of data, including alteration, deletion, and selective disclosure disassociability: enabling the processing of data or events without association to individuals or devices beyond the operational requirements of the system

Table 3-2 below demonstrates the problematic data action taxonomy identified for the entire RPM ecosystem. This Problematic Data Action Taxonomy uses: a predictability (P), manageability (M), and disassociability (D) designation; the problematic data action considered; and the description of the problematic data action. While the Problematic Data Action Taxonomy provides a landscape view of problematic data action, an organization may want to perform a risk assessment to determine contextual application of the problematic data action. The discussion about problematic data actions and risks in Appendix D introduces the PRAM [7] and provides a more detailed analysis. Table 3-2 Problematic Data Action Taxonomy P, M, D

Description

P, M

Problematic Data Action distortion

M

insecurity

Lapses in data security can result in various problems, including loss of trust, exposure to economic loss and other identity theft-related harms, and dignity losses.

D, M

re-identification

De-identified data, or data otherwise disassociated from specific individuals, become identifiable or associated with specific individuals again. It can lead to problems such as discrimination, loss of trust, and dignity losses.

P, M

unanticipated revelation

Data reveal or expose an individual or facets of an individual in unexpected ways. Unanticipated revelation can arise from aggregation and analysis of

Inaccurate or misleadingly incomplete data are used or disseminated. Distortion can present users in an inaccurate, unflattering, or disparaging manner, opening the door for stigmatization, discrimination, or loss of liberty.

NIST SP 1800-30B: Securing Telehealth Remote Patient Monitoring Ecosystem

10

P, M, D

Problematic Data Action

Description large and/or diverse data sets. Unanticipated revelation can give rise to dignity losses, discrimination, and loss of trust and autonomy.

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

The project team used the NIST PRAM [7] and accompanying Catalog of Problematic Data Actions and Problems [8] to conduct this analysis. Table 3-2, Problematic Data Action Taxonomy, provides the results of this analysis. See Appendix D for additional considerations regarding examples of problematic data actions for RPM solutions.

3.4.4

Risk

As noted in Section 3.4, NIST SP 800-30 Revision 1, Guide for Conducting Risk Assessments, defines risk as “a measure of the extent to which an entity is threatened by potential circumstance or event, and is typically a function of: (i) the adverse impacts that would arise if the circumstance or event occurs; and (ii) the likelihood of occurrence” [9]. Risk is the adverse impact; that is, risk is the result when a threat (attack) successfully leverages one or more vulnerabilities. As organizations consider risk, they should note that risk is not discrete; that is, one may realize multiple risks based on a successful attack. Notwithstanding, we consider those risks identified below. In reviewing these risks, please note that we consider unique scenarios that presume certain attack types for the two risks categorized as availability risks, those being ransomware and pivot point attacks. Table 3-3, Cybersecurity Risk Taxonomy, describes high-level cybersecurity risks that affect the RPM environment. The risk taxonomy table captures key risks, assigning where the risk may impact the organization across a confidentiality, integrity, and availability (CIA) [6] dimension. Table 3-3 Cybersecurity Risk Taxonomy C, I, A

Risk

Description

Risk Level

C

fraudulent use of healthrelated information

Health-related information may be used for several different fraudulent means, such as identity theft, insurance fraud, or extortion.

medium

I

patient diagnoses disrupted based on

Unavailability or significant delay in delivering biometric data may negate the benefits of remote patient monitoring. Clinicians may not

medium

NIST SP 1800-30B: Securing Telehealth Remote Patient Monitoring Ecosystem

11

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

C, I, A

Risk timeliness interruption, leading to patient safety concerns

Description be able to provide appropriate care should biometric data transmission be disrupted.

Risk Level

I

incorrect patient diagnosis due to change of data

A critical patient event is missed due to changes in the data stream between device and HDO.

high

A

process disruption due to ransomware

Ransomware may prevent normal device operations. Data may be irretrievable and, therefore, may prevent clinical care.

high

I, A

systemic disruption due to component compromise

Disruptions to the system that affect its availability or integrity may compromise the benefits derived from remote patient monitoring.

high

I

clinician misdiagnosis

If data are altered inappropriately, clinicians may make inaccurate diagnoses, resulting in patient safety issues.

high

Table 3-4, Privacy Risk Taxonomy, describes high-level privacy risks that affect the RPM environment. Table 3-4 captures key risks, assigning where the risk may impact individuals, in the areas of predictability, manageability, and disassociability [5]. Privacy risk levels to individuals depend on the context of specific RPM solution deployment and are not included. These risks are discussed further in Appendix D. Table 3-4 Privacy Risk Taxonomy P, M, D M

Risk Storage and movement of data create multiple points of potential exposure after data are collected from the patient.

Description Insecurity: Storage and movement of data create multiple points of potential exposure after they are collected from the patient. RPM context: Biometric data and patient health information flow through various entities in the RPM solution, each of which plays a role in protecting the information.

NIST SP 1800-30B: Securing Telehealth Remote Patient Monitoring Ecosystem

12

P, M, D P, M

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

P, M

D, M

Risk Biometric device types can indicate patient health problems that individuals would prefer not to disclose beyond their healthcare provider.

Description Unanticipated revelation: Biometric device types can indicate patient health problems that individuals would prefer not to disclose beyond their healthcare provider.

Incorrect data capture of readings by devices may impact quality of patient care.

Distortion: Device misuse may cause a failure to monitor patients in accordance with their healthcare plan.

Aggregated data may expose patient information.

Re-identification: Associating biometric data with patient identifiers can expose health conditions.

RPM context: Using one or more biometric devices can indicate—to others beyond the patient’s healthcare provider—potential health problems for which a patient is being monitored.

RPM context: Incorrect or unintended use of biometric devices may introduce data quality issues into the RPM environment, resulting in inaccurate or incomplete data being used to make decisions regarding patient care.

RPM context: Associating biometric data in a way that exposes information about the patient could cause issues such as embarrassment and discrimination. Disassociated processing is intentionally used during some dataflows within the RPM solution to mitigate the risk of exposing identifiable patient information to vendors, administrators, and other practitioners who are outside the patient’s care team. P, M

Exposure of patient information through multiple providers of system components increases the likelihood of exposure of patient data to unintended recipients.

Unanticipated Revelation: Data processing is handled by multiple parties within the background of the ecosystem and is transparent to the patient. RPM context: Patient health information may be revealed in ways or to parties that the individual may not expect. Additionally, using one or more biometric devices can indicate potential health problems—to others beyond the patient’s healthcare provider—for which a patient is being monitored.

NIST SP 1800-30B: Securing Telehealth Remote Patient Monitoring Ecosystem

13

3.4.5

Mitigating Risk

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

As noted above, risk is the adverse outcome when a threat successfully leverages a vulnerability. Mitigating risk may take many different forms. This practice guide addresses risk by performing a threat modeling exercise and by mitigating threats. The previous sections discussed threat from a holistic perspective. That is, the noted threats enumerate a broad survey of attack types that may adversely affect the RPM ecosystem. RPM decomposes to the following three distinct domains: patient home, telehealth platform provider, and HDO. As organizations consider measures to disrupt threats and adverse actions made against the ecosystem, an opportunity exists where organizations examine threats to identify controls that mitigate adverse actions identified by threat modeling.

3.5 Security Control Map As this practice guide considered RPM ecosystem risks, the team performed a mapping to the NIST Cybersecurity Framework [3]. This mapping established an initial set of appropriate control Functions, Categories, and Subcategories. The mapping demonstrated how selected Cybersecurity Framework Subcategories map to controls in NIST SP 800-53 Revision 5 [10] as well as to the Workforce Framework for Cybersecurity (NICE Framework), NIST SP 800-181 [2]. The table also lists sector-specific standards and best practices (e.g., the International Electrotechnical Commission [IEC] Technical Reports [TR], International Organization for Standardization [ISO]) as well as from the Health Insurance Portability and Accountability Act (HIPAA) [11], [12], [13]). The security control map, shown in Table 3-5, identifies a set of controls, including those specifically implemented in the lab build, as well as the pervasive set of controls as described in Section 5.2, Pervasive Controls, that HDOs should deploy. Practitioners should refer to Appendix C of NIST SP 1800-24, Securing Picture Archiving and Communication System (PACS) for further description of pervasive controls [14].

NIST SP 1800-30B: Securing Telehealth Remote Patient Monitoring Ecosystem

14

Table 3-5 Security Characteristics and Controls Mapping–NIST Cybersecurity Framework NIST Cybersecurity Framework v1.1 Function

Category

Subcategory

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

ID.AM-1: Physical devices and systems within the organization are inventoried

IDENTIFY (ID)

Asset Management (ID.AM)

ID.AM-2: Software platforms and applications within the organization are inventoried

ID.AM-4: External information systems are catalogued

ID.AM-5: Resources (e.g., hardware, devices, data, time, personnel, and software) are prioritized based on their classification, criticality, and business value

NIST SP 800-53 Revision 5

NIST NICE Framework (NIST SP 800-181)

CM-8 PM-5

Sector-Specific Standards and Best Practices IEC TR 80001-2-2

HIPAA Security Rule

ISO/IEC 27001

N/A

45 C.F.R. §§ 164.308(a)(1)(ii)(A) 164.308(a)(4)(ii)(A) 164.308(a)(7)(ii)(E) 164.308(b) 164.310(d) 164.310(d)(2)(iii)

A.8.1.1 A.8.1.2

45 C.F.R. §§ 164.308(a)(1)(ii)(A) 164.308(a)(7)(ii)(E )

A.8.1.1 A.8.1.2 A.12.5.1

45 C.F.R. §§ 164.308(a)(4)(ii)(A) 164.308(b) 164.314(a)(1) 164.314(a)(2)(i)(B) 164.314(a)(2)(ii) 164.316(b)(2)

A.11.2.6

45 C.F.R. §§ 164.308(a)(7)(ii)(E)

A.8.2.1

CM-8

AC-20 PM-5 SA-9

CP-2RA-2 RA-9 SA-20 SC-6

NIST SP 1800-30B: Securing Telehealth Remote Patient Monitoring Ecosystem

SGUD CO-OPL-001

15

NIST Cybersecurity Framework v1.1 Function

Category

NIST NICE Framework (NIST SP 800-181)

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

Subcategory

NIST SP 800-53 Revision 5

ID.RA-1: Asset vulnerabilities are identified and documented

CA-2 CA-5 CA-7 CA-8 PM-4 PM-15RA3 RA-5 SA-5 SA-11 SI-2 SI-4 SI-5

AN-ASA-001 AN-ASA-002 AN-TWA001 CO-CLO-002 CO-OPS-001 SP-ARC-001

CP-2 PM-9 PM-11 RA-2 RA-3 RA-9

AN-ASA-001 AN-ASA-002 AN-EXP-001 AN-LNG-001 AN-TGT-001 AN-TGT-002 AN-TWA001 CO-CLO-001 CO-CLO-002 CO-OPL-001 CO-OPL-002

Risk Assessment (ID.RA)

ID.RA-4: Potential business impacts and likelihoods are identified

NIST SP 1800-30B: Securing Telehealth Remote Patient Monitoring Ecosystem

Sector-Specific Standards and Best Practices IEC TR 80001-2-2

MLDP RDMP SGUD

DTBK SGUD

HIPAA Security Rule

ISO/IEC 27001

45 C.F.R. §§ 164.308(a)(1)(i) 164.308(a)(1)(ii)(A) 164.308(a)(1)(ii)(B) 164.308(a)(7)(ii)(E) 164.308(a)(8) 164.310(a)(1)

A.12.6.1 A.18.2.3

45 C.F.R. §§ 164.308(a)(1)(i) 164.308(a)(1)(ii)(A) 164.308(a)(1)(ii)(B) 164.308(a)(6) 164.308(a)(7)(ii)(E) 164.308(a)(8)

A.16.1.6 Clause 6.1.2

16

NIST Cybersecurity Framework v1.1 Function

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

PROTECT (PR)

Category

Identity Management, Authentication and Access Control (PR.AC)

Subcategory

NIST SP 800-53 Revision 5

ID.RA-5: Threats, vulnerabilities, likelihoods, and impacts are used to determine risk

CA-2 CA-7 PM-16 PM-28 RA-2 RA-3

ID.RA-6: Risk responses are identified and prioritized

CA-5 PM-4 PM-9 PM-28 RA-7

PR.AC-1: Identities and credentials are issued, managed, verified, revoked, and audited for authorized devices, users and processes

IA-1 IA-2 IA-3 IA-4 IA-5 IA-7 IA-8 IA-9 IA-10 IA-11 IA-12

NIST SP 1800-30B: Securing Telehealth Remote Patient Monitoring Ecosystem

NIST NICE Framework (NIST SP 800-181)

SP-SYS-001

SP-SYS-001

OM-ADM001

Sector-Specific Standards and Best Practices IEC TR 80001-2-2

HIPAA Security Rule

ISO/IEC 27001

SGUD

45 C.F.R. §§ 164.308(a)(1)(ii)(A) 164.308(a)(1)(ii)(B) 164.308(a)(1)(ii)(D) 164.308(a)(7)(ii)(D) 164.308(a)(7)(ii)(E) 164.316(a)

A.12.6.1

DTBK SGUD

45 C.F.R. §§ 164.308(a)(1)(ii)(B) 164.314(a)(2)(i)(C) 164.314(b)(2)(iv)

Clause 6.1.3

ALOF AUTH EMRG NAUT PAUT

45 C.F.R. §§ 164.308(a)(3)(ii)(B) 164.308(a)(3)(ii)(C) 164.308(a)(4)(i) 164.308(a)(4)(ii)(B) 164.308(a)(4)(ii)(C ) 164.312(a)(2)(i)

A.9.2.1 A.9.2.2 A.9.2.3 A.9.2.4 A.9.2.6 A.9.3.1 A.9.4.2 A.9.4.3

17

NIST Cybersecurity Framework v1.1 Function

Category

Subcategory

NIST SP 800-53 Revision 5

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

PR.AC-2: Physical access to assets is managed and protected

PE-1 PE-2 PE-3 PE-4 PE-5 PE-6 PE-8 PE-9

PR.AC-3: Remote access is managed

AC-1 AC-17 AC-19 AC-20 SC-15

PR.AC-4: Access permissions and authorizations are managed, incorporating the principles of least privilege and separation of duties

AC-1 AC-2 AC-3 AC-5 AC-6 AC-14 AC-16 AC-24

NIST SP 1800-30B: Securing Telehealth Remote Patient Monitoring Ecosystem

NIST NICE Framework (NIST SP 800-181)

OM-ADM001

OM-ADM001

OM-ADM001 OM-KMG001 PR-INF-001

Sector-Specific Standards and Best Practices IEC TR 80001-2-2

HIPAA Security Rule

ISO/IEC 27001

PLOK TXCF TXIG

45 C.F.R. §§ 164.308(a)(1)(ii)(B) 164.308(a)(7)(i) 164.308(a)(7)(ii)(A) 164.310(a)(1) 164.310(a)(2)(i) 164.310(a)(2)(ii)

A.11.1.1 A.11.1.2 A.11.1.3 A.11.1.4 A.11.1.5 A.11.1.6 A.11.2.1 A.11.2.3 A.11.2.5 A.11.2.6 A.11.2.7 A.11.2.8

ALOF AUTH CSUP EMRG NAUT PAUT

45 C.F.R. §§ 164.308(a)(4)(i) 164.308(b)(1) 164.308(b)(3) 164.310(b) 164.312(e)(1) 164.312(e)(2)(ii)

A.6.2.1 A.6.2.2 A.11.2.6 A.13.1.1 A.13.2.1

ALOF AUTH CNFS EMRG NAUT PAUT

45 C.F.R. §§ 164.308(a)(3) 164.308(a)(4) 164.310(a)(2)(iii) 164.310(b) 164.312(a)(1) 164.312(a)(2)(i)

A.6.1.2 A.9.1.2 A.9.2.3 A.9.4.1 A.9.4.4 A.9.4.5

18

NIST Cybersecurity Framework v1.1 Function

Category

Subcategory

NIST SP 800-53 Revision 5

NIST NICE Framework (NIST SP 800-181)

Sector-Specific Standards and Best Practices

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

IEC TR 80001-2-2

HIPAA Security Rule

ISO/IEC 27001

PR.AC-5: Network integrity is protected (e.g., network segregation, network segmentation)

AC-4 AC-10 SC-7 SC-10 SC-20

MLDP NAUT

45 C.F.R. §§ 164.308(a)(4)(ii)(B) 164.310(a)(1) 164.310(b) 164.312(a)(1) 164.312(b) 164.312(c)

A.13.1.1 A.13.1.3 A.13.2.1 A.14.1.2 A.14.1.3

PR.AC-6: Identities are proofed and bound to credentials and asserted in interactions

AC-16 IA-1 IA-2 IA-4 IA-5 IA-8 IA-12 PE-2 PS-3

AUTH CNFS EMRG NAUT PLOK SGUD

N/A

A.7.1.1 A.9.1.2

NIST SP 1800-30B: Securing Telehealth Remote Patient Monitoring Ecosystem

SP-RSK-002 OV-PMA003

19

NIST Cybersecurity Framework v1.1 Function

Category

NIST NICE Framework (NIST SP 800-181)

Sector-Specific Standards and Best Practices

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

Subcategory

NIST SP 800-53 Revision 5

PR.AC-7: Users, devices, and other assets are authenticated (e.g., single-factor, multifactor) commensurate with the risk of the transaction (e.g., individuals’ security and privacy risks and other organizational risks)

AC-14 IA-1 IA-2 IA-3 IA-5 IA-8 IA-9 IA-10 IA-11

ALOF AUTH NAUT PAUT

PR.DS-1: Data-at-rest is protected

MP-2 MP-3 MP-4 MP-5 MP-6 MP-7 MP-8 SC-28

IGAU MLDP NAUT SAHD STCF TXCF

45 C.F.R. §§ 164.308(a)(1)(ii)(D) 164.308(b)(1) 164.310(d) 164.312(a)(1) 164.312(a)(2)(iii) 164.312(a)(2)(iv)

A.8.2.3

IGAU NAUT STCF TXCF TXIG

45 C.F.R. §§ 164.308(b)(1) 164.308(b)(2) 164.312(e)(1) 164.312(e)(2)(i) 164.312(e)(2)(ii) 164.314(b)(2)(i)

A.8.2.3 A.13.1.1 A.13.2.1 A.13.2.3 A.14.1.2 A.14.1.3

Data Security (PR.DS)

PR.DS-2: Data-in-transit is protected

SC-8 SC-11

NIST SP 1800-30B: Securing Telehealth Remote Patient Monitoring Ecosystem

OM-DTA002 PR-CDA-001

IEC TR 80001-2-2

HIPAA Security Rule

ISO/IEC 27001

A.9.2.1 A.9.2.4 A.9.3.1 A.9.4.2 A.9.4.3 A.18.1.4

20

NIST Cybersecurity Framework v1.1 Function

Category

Subcategory

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

PR.DS-3: Assets are formally managed throughout removal, transfers, and disposition

PR.DS-4: Adequate capacity to ensure availability is maintained

NIST SP 800-53 Revision 5 CM-8 MP-6 PE-16 PE-20

AU-4 CP-2 PE-11 SC-5

NIST SP 1800-30B: Securing Telehealth Remote Patient Monitoring Ecosystem

NIST NICE Framework (NIST SP 800-181)

Sector-Specific Standards and Best Practices IEC TR 80001-2-2

HIPAA Security Rule

ISO/IEC 27001

N/A

45 C.F.R. §§ 164.308(a)(1)(ii)(A) 164.310(a)(2)(ii) 164.310(a)(2)(iii) 164.310(a)(2)(iv) 164.310(d)(1) 164.310(d)(2)

A.8.2.3 A.8.3.1 A.8.3.2 A.8.3.3 A.11.2.5 A.11.2.7

AUDT DTBK

45 C.F.R. §§ 164.308(a)(1)(ii)(A) 164.308(a)(1)(ii)(B) 164.308(a)(7) 164.310(a)(2)(i) 164.310(d)(2)(iv) 164.312(a)(2)(ii)

A.12.1.3 A.17.2.1

21

NIST Cybersecurity Framework v1.1 Function

Category

Subcategory

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

PR.DS-5: Protections against data leaks are implemented

PR.DS-6: Integrity checking mechanisms are used to verify software, firmware, and information integrity

NIST SP 800-53 Revision 5

AC-4 AC-5 AC-6 AU-13 PE-19 PS-6 SC-7 SI-4

SI-7 SI-10

NIST SP 1800-30B: Securing Telehealth Remote Patient Monitoring Ecosystem

NIST NICE Framework (NIST SP 800-181)

SP-SYS-001

Sector-Specific Standards and Best Practices IEC TR 80001-2-2

HIPAA Security Rule

ISO/IEC 27001

AUTH IGAU MLDP PLOK STCF TXCF TXIG

45 C.F.R. §§ 164.308(a)(1)(ii)(D) 164.308(a)(3) 164.308(a)(4) 164.310(b) 164.310(c) 164.312(a)

A.6.1.2 A.7.1.1 A.7.1.2 A.7.3.1 A.8.2.2 A.8.2.3 A.9.1.1 A.9.1.2 A.9.2.3 A.9.4.1 A.9.4.4 A.9.4.5 A.10.1.1 A.11.1.4 A.11.1.5 A.11.2.1 A.13.1.1 A.13.1.3 A.13.2.1 A.13.2.3 A.13.2.4 A.14.1.2 A.14.1.3

IGAU MLDP

45 C.F.R. §§ 164.308(a)(1)(ii)(D) 164.312(b) 164.312(c)(1) 164.312(c)(2) 164.312(e)(2)(i)

A.12.2.1 A.12.5.1 A.14.1.2 A.14.1.3 A.14.2.4

22

NIST Cybersecurity Framework v1.1 Function

Category

Subcategory

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

PR.IP-4: Backups of information are conducted, maintained, and tested

Information Protection (PR.IP)

NIST SP 800-53 Revision 5

NIST NICE Framework (NIST SP 800-181)

CP-4 CP-6 CP-9

PR.IP-6: Data is destroyed according to policy

MP-6 SR-12

PR.IP-9: Response plans (Incident Response and Business Continuity) and recovery plans (Incident Recovery and Disaster Recovery) are in place and managed

CP-1 CP-2 CP-7 CP-10 IR-1 IR-7 IR-8 IR-9

PR.IP-10: Response and recovery plans are tested

CP-4 IR-3 PM-14

PR.IP-12: A vulnerability management plan is developed and implemented

RA-1 RA-3 RA-5 SI-2

NIST SP 1800-30B: Securing Telehealth Remote Patient Monitoring Ecosystem

OM-NET001

OV-PMA001

Sector-Specific Standards and Best Practices IEC TR 80001-2-2

HIPAA Security Rule

ISO/IEC 27001

DTBK PLOK

164.308(a)(7)(ii)(A) 164.308(a)(7)(ii)(B) 164.308(a)(7)(ii)(D) 164.310(a)(2)(i) 164.310(d)(2)(iv)

A.12.3.1 A.17.1.2 A.17.1.3 A.18.1.3

DIDT

45 C.F.R. §§ 164.310(d)(2)(i) 164.310(d)(2)(ii)

A.8.2.3 A.8.3.1 A.8.3.2 A.11.2.7

DTBK SGUD

45 C.F.R. §§ 164.308(a)(6) 164.308(a)(6)(i) 164.308(a)(7) 164.310(a)(2)(i) 164.312(a)(2)(ii)

A.16.1.1 A.17.1.1 A.17.1.2 A.17.1.3

DTBK SGUD

45 C.F.R. §§ 164.308(a)(7)(ii)(D)

A.17.1.3

MLDP

45 C.F.R. §§ 164.308(a)(1)(i) 164.308(a)(1)(ii)(A) 164.308(a)(1)(ii)(B)

A.12.6.1 A.14.2.3 A.16.1.3 A.18.2.2 A.18.2.3

23

NIST Cybersecurity Framework v1.1 Function

Category

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

Maintenance (PR.MA)

Protective Technology (PR.PT)

Subcategory

NIST SP 800-53 Revision 5

PR.MA-1: Maintenance and repair of organizational assets are performed and logged, with approved and controlled tools

MA-1 MA-2 MA-3 MA-5 MA-6

PR.MA-2: Remote maintenance of organizational assets is approved, logged, and performed in a manner that prevents unauthorized access

MA-4

PR.PT-1: Audit/log records are determined, documented, implemented, and reviewed in accordance with policy

AU-1 AU-2 AU-3 AU-6 AU-7 AU-12 AU-13 AU-14 AU-16

NIST SP 1800-30B: Securing Telehealth Remote Patient Monitoring Ecosystem

NIST NICE Framework (NIST SP 800-181) OM-ADM001 PR-INF-001

OV-PMA001 OV-PMA002 OV-PMA003 OV-PMA004 OV-PMA005

Sector-Specific Standards and Best Practices IEC TR 80001-2-2

HIPAA Security Rule

ISO/IEC 27001

CSUP RDMP

45 C.F.R. §§ 164.308(a)(3)(ii)(A) 164.310(a)(2)(iv)

A.11.1.2 A.11.2.4 A.11.2.5 A.11.2.6

CSUP

45 C.F.R. §§ 164.308(a)(1)(ii)(D) 164.308(a)(3)(ii)(A) 164.310(d)(1) 164.310(d)(2)(ii) 164.310(d)(2)(iii) 164.312(a) 164.312(a)(2)(ii) 164.312(a)(2)(iv) 164.312(b) 164.312(d) 164.312(e)

A.11.2.4 A.15.1.1 A.15.2.1

AUDT

45 C.F.R. §§ 164.308(a)(1)(i) 164.308(a)(1)(ii)(D) 164.308(a)(5)(ii)(B) 164.308(a)(5)(ii)(C) 164.308(a)(2) 164.308(a)(3)(ii)(A)

A.12.4.1 A.12.4.2 A.12.4.3 A.12.4.4 A.12.7.1

24

NIST Cybersecurity Framework v1.1 Function

Category

Subcategory

NIST SP 800-53 Revision 5

NIST NICE Framework (NIST SP 800-181)

Sector-Specific Standards and Best Practices

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

IEC TR 80001-2-2

HIPAA Security Rule

ISO/IEC 27001

AUTH CNFS SAHD

45 C.F.R. §§ 164.308(a)(3) 164.308(a)(4) 164.310(a)(2)(iii) 164.310(b) 164.310(c) 164.312(a)(1)

A.9.1.2

OV-SPP-001 OV-SPP-002

PR.PT-3: The principle of least functionality is incorporated by configuring systems to provide only essential capabilities

AC-3 CM-7

NIST SP 1800-30B: Securing Telehealth Remote Patient Monitoring Ecosystem

25

NIST Cybersecurity Framework v1.1 Function

Category

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

DETECT (DE)

Anomalies and Events (DE.AE)

Subcategory

NIST SP 800-53 Revision 5

PR.PT-4: Communications and control networks are protected

AC-12 AC-17 AC-18 CP-8 SC-5 SC-7 SC-10 SC-11 SC-20 SC-21 SC-22 SC-23 SC-31 SC-37 SC-38 SC-47

DE.AE-1: A baseline of network operations and expected data flows for users and systems is established and managed

AC-4 CA-3 CM-2 SC-16 SI-4

NIST SP 1800-30B: Securing Telehealth Remote Patient Monitoring Ecosystem

NIST NICE Framework (NIST SP 800-181)

OV-EXL-001 OV-MGT001

Sector-Specific Standards and Best Practices IEC TR 80001-2-2

HIPAA Security Rule

ISO/IEC 27001

AUTH MLDP PAUT SAHD

45 C.F.R. §§ 164.308(a)(1)(ii)(D) 164.312(a)(1) 164.312(b) 164.312(e)

A.13.1.1 A.13.2.1 A.14.1.3

CNFS CSUP MLDP

45 C.F.R. §§ 164.308(a)(1)(ii)(D) 164.312(b)

A.12.1.1 A.12.1.2 A.13.1.1 A.13.1.2

26

NIST Cybersecurity Framework v1.1 Function

Category

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

NIST NICE Framework (NIST SP 800-181)

Sector-Specific Standards and Best Practices IEC TR 80001-2-2

HIPAA Security Rule

ISO/IEC 27001

AU-6 CA-7 RA-5 IR-4 SI-4

AN-LNG-001 CO-CLO-002 IN-FOR-001 OM-DTA002 OM-STS-001 PR-CDA-001

AUDT MLDP

45 C.F.R. §§ 164.308(a)(1)(i) 164.308(a)(1)(ii)(D) 164.308(a)(5)(ii)(B) 164.308(a)(5)(ii)(C) 164.308(6)(i) 164.308(a)(6)(i)

A.12.4.1 A.16.1.1 A.16.1.4

DE.CM-1: The network is monitored to detect potential cybersecurity events

AU-12 CA-7 CM-3 SC-5 SC-7 SI-4

AN-ASA-001 AN-ASA-002 AN-EXP-001 AN-TWA001 CO-CLO-001 OM-DTA001 OM-KMG001 OM-NET001 OV-EXL-001 OV-LGA-002 OV-MGT001

AUDT CNFS CSUP MLDP NAUT

45 C.F.R. §§ 164.308(a)(1)(i) 164.308(a)(1)(ii)(D) 164.308(a)(5)(ii)(B) 164.308(a)(5)(ii)(C) 164.308(a)(2) 164.308(a)(3)(ii)(A)

N/A

DE.CM-2: The physical environment is monitored to detect

CA-7 PE-6 PE-20

AN-ASA-001 AN-ASA-002

MLDP

45 C.F.R. §§ 164.310(a)(2)(ii) 164.310(a)(2)(iii)

A.11.1.1 A.11.1.2

Subcategory

DE.AE-2: Detected events are analyzed to understand attack targets and methods

Security Continuous Monitoring (DE.CM)

NIST SP 800-53 Revision 5

NIST SP 1800-30B: Securing Telehealth Remote Patient Monitoring Ecosystem

27

NIST Cybersecurity Framework v1.1 Function

Category

NIST SP 800-53 Revision 5

NIST NICE Framework (NIST SP 800-181)

Sector-Specific Standards and Best Practices

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

IEC TR 80001-2-2

HIPAA Security Rule

ISO/IEC 27001

DE.CM-4: Malicious code is detected

SC-44 SI-3 SI-4 SI-8

IGAU MLDP

45 C.F.R. §§ 164.308(a)(1)(ii)(D) 164.308(a)(5)(ii)(B)

A.12.2.1

DE.CM-5: Unauthorized mobile code is detected

SC-18 SC-44 SI-4

MLDP SGUD

45 C.F.R. §§ 164.308(a)(1)(ii)(D) 164.308(a)(5)(ii)(B)

A.12.5.1 A.12.6.2

DE.CM-7: Monitoring for unauthorized personnel, connections, devices, and software is performed

AU-12 CA-7 CM-3 CM-8 PE-6 PE-20 SI-4

AUDT PAUT PLOK

45 C.F.R. §§ 164.308(a)(1)(ii)(D) 164.308(a)(5)(ii)(B) 164.308(a)(5)(ii)(C) 164.310(a)(1) 164.310(a)(2)(ii) 164.310(a)(2)(iii)

A.12.4.1 A.14.2.7 A.15.2.1

MLDP PLOK

45 C.F.R. §§ 164.308(a)(1)(i) 164.308(a)(8)

A.12.6.1

Subcategory potential cybersecurity events

DE.CM-8: Vulnerability scans are performed

AN-TWA001

RA-5

NIST SP 1800-30B: Securing Telehealth Remote Patient Monitoring Ecosystem

AN-EXP-001 IN-FOR-002 SP-DEV-002

28

NIST Cybersecurity Framework v1.1 Function

Category

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

Response Planning (RS.RP) RESPOND (RS)

Improvements (RS.IM)

RECOVER (RC)

Recovery Planning (RC.RP)

Subcategory

NIST SP 800-53 Revision 5

NIST NICE Framework (NIST SP 800-181)

Sector-Specific Standards and Best Practices IEC TR 80001-2-2

HIPAA Security Rule

ISO/IEC 27001

DTBK MLDP SGUD

45 C.F.R. §§ 164.308(a)(6)(ii) 164.308(a)(7)(i) 164.308(a)(7)(ii)(A) 164.308(a)(7)(ii)(B) 164.308(a)(7)(ii)(C) 164.310(a)(2)(i) 164.312(a)(2)(ii)

A.16.1.5

A.16.1.6 Clause 10

RS.RP-1: Response plan is executed during or after an event

CP-2 CP-10 IR-4 IR-8

RS.IM-1: Response plans incorporate lessons learned

CP-2 IR-4 IR-8

DTBK

45 C.F.R. §§ 164.308(a)(7)(ii)(D) 164.308(a)(8) 164.316(b)(2)(iii)

RS.IM-2: Response strategies are updated

CP-2 IR-4 IR-8

DTBK

45 C.F.R. §§ 164.308(a)(7)(ii)(D) 164.308(a)(8)

A.16.1.6 Clause 10

DTBK MLDP SGUD

45 C.F.R. §§ 164.308(a)(7) 164.308(a)(7)(i) 164.308(a)(7)(ii) 164.308(a)(7)(ii)(C) 164.310(a)(2)(i) 164.312(a)(2)(ii)

A.16.1.5

RC.RP-1: Recovery plan is executed during or after a cybersecurity incident

CP-10 IR-4 IR-8

NIST SP 1800-30B: Securing Telehealth Remote Patient Monitoring Ecosystem

OM-ADM001

29

Table 3-6 identifies the NIST Privacy Framework v1.0 Functions, Categories, and Subcategories implemented in the lab build that the solution supports and demonstrates how they map to controls in the final published version of NIST SP 800-53, Revision 5 [5], [10]. Practitioners should refer to the Privacy Framework Resource Repository for the comprehensive mapping of the Privacy Framework and Cybersecurity Framework to NIST SP 800-53, Revision 5. HDOs should evaluate controls that align with their identified risks [15] . This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

Table 3-6 Privacy Characteristics and Controls Mapping–NIST Privacy Framework NIST Privacy Framework v1.0 Function

Category

Inventory and Mapping (ID.IM-P)

Identify—P

Risk Assessment (ID.RA-P)

Control–P

Data Processing

Subcategory

NIST SP 800-53 Revision 5

ID.IM-P1: Systems/products/services that process data are inventoried.

CM-8, CM-12, CM-13, PM-5

ID.IM-P2: Owners or operators (e.g., the organization or third parties such as service providers, partners, customers, and developers) and their roles with respect to the systems/products/services and components (e.g., internal or external) that process data are inventoried.

CM-8(4), CM-13

ID.IM-P7: The data processing environment is identified (e.g., geographic location, internal, cloud, third parties).

CM-8, CM-12, CM-13

ID.RA-P3: Potential problematic data actions and associated problems are identified.

CM-13, RA-3, RA-8

ID.RA-P4: Problematic data actions, likelihoods, and impacts are used to determine and prioritize risk.

PM-28, RA-2, RA-3, RA-8

ID.RA-P5: Risk responses are identified, prioritized, and implemented.

CA-5, PM-4, PM-9, PM-28, RA-7, RA-8

CT.DM-P5: Data are destroyed according to policy.

MP-6, SI-12(3), SR-12

NIST SP 1800-30B: Securing Telehealth Remote Patient Monitoring Ecosystem

30

NIST Privacy Framework v1.0 Function

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

Category

Subcategory

NIST SP 800-53 Revision 5

Management (CT.DM-P)

CT.DM-P8: Audit/log records are determined, documented, implemented, and reviewed in accordance with policy and incorporating the principle of data minimization.

AU-1, AU-2, AU-3, AU-6, AU7, AU-12, AU-13, AU-14, AU16

PR.PO-P3: Backups of information are conducted, maintained, and tested.

CP-4, CP-6, CP-9

PR.PO-P7: Response plans (Incident Response and Business Continuity) and recovery plans (Incident Recovery and Disaster Recovery) are established, in place, and managed.

CP-1, CP-2, CP-7, CP-10, IR-1, IR-7, IR-8, IR-9

PR.PO-P8: Response and recovery plans are tested.

CP-4, IR-3, PM-14

PR.PO-P10: A vulnerability management plan is developed and implemented.

RA-1, RA-3, RA-5, SI-2

PR.AC-P1: Identities and credentials are issued, managed, verified, revoked, and audited for authorized individuals, processes, and devices.

IA-1, IA-2, IA-3, IA-4, IA-5, IA7, IA-8, IA-9, IA-10, IA-11, IA12

PR.AC-P2: Physical access to data and devices is managed.

PE-1, PE-2, PE-3, PE-4, PE-5, PE-6, PE-8, PE-9

PR.AC-P3: Remote access is managed.

AC-1, AC-17, AC-19, AC-20, SC-15

Data Protection Policies, Processes, and Procedures

Protect—P

Identity Management, Authentication, and Access Control

NIST SP 1800-30B: Securing Telehealth Remote Patient Monitoring Ecosystem

31

NIST Privacy Framework v1.0 Function

Category

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

Data Security (PR.DS-P)

Subcategory

NIST SP 800-53 Revision 5

PR.AC-P4: Access permissions and authorizations are managed, incorporating the principles of least privilege and separation of duties.

AC-1, AC-2, AC-3, AC-5, AC-6, AC-14, AC-16, AC-24

PR.AC-P5: Network integrity is protected (e.g., network segregation, network segmentation).

AC-4, AC-10, SC-7, SC-10, SC20

PR.AC-P6: Individuals and devices are proofed and bound to credentials, and authenticated commensurate with the risk of the transaction (e.g., individuals’ security and privacy risks and other organizational risks).

AC-14, AC-16, IA-1, IA-2, IA-3, IA-4, IA-5, IA-8, IA-9, IA-10, IA-11, IA-12, PE-2, PS-3

PR.DS-P1: Data-at-rest are protected.

MP-2, MP-3, MP-4, MP-5, MP-6, MP-7, MP-8, SC-28

PR.DS-P2: Data-in-transit are protected.

SC-8, SC-11

PR.DS-P3: Systems/products/services and associated data are formally managed throughout removal, transfers, and disposition.

CM-8, MP-6, PE-16, PE-20

PR.DS-P4: Adequate capacity to ensure availability is maintained.

AU-4, CP-2, PE-11, SC-5

PR.DS-P5: Protections against data leaks are implemented.

AC-4, AC-5, AC-6, AU-13, PE19, PS-6, SC-7, SI-4

NIST SP 1800-30B: Securing Telehealth Remote Patient Monitoring Ecosystem

32

NIST Privacy Framework v1.0 Function

Category

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

Maintenance (PR.MA-P)

Protective Technology (PR.PT-P)

Subcategory

NIST SP 800-53 Revision 5

PR.DS-P6: Integrity checking mechanisms are used to verify software, firmware, and information integrity.

SC-16, SI-7, SI-10

PR.MA-P1: Maintenance and repair of organizational assets are performed and logged, with approved and controlled tools.

MA-1, MA-2, MA-3, MA-5, MA-6

PR.MA-P2: Remote maintenance of organizational assets is approved, logged, and performed in a manner that prevents unauthorized access.

MA-4

PR.PT-P2: The principle of least functionality is incorporated by configuring systems to provide only essential capabilities.

AC-3, CM-7

PR.PT-P3: Communications and control networks are protected.

AC-12, AC-17, AC-18, CP-8, SC-5, SC-7, SC-10, SC-11, SC20, SC-21, SC-22, SC-23, SC31, SC-37, SC-38, SC-47

3.6 Technologies Table 3-7 lists all of the technologies used in this project and provides a mapping among the generic application terms, the specific product used, and the security control(s) that the product provides. Refer to Table 3-5 for an explanation of the NIST Cybersecurity Framework Subcategory codes and Table 3-6 for an explanation of the NIST Privacy Framework Subcategory codes. While this practice guide notes that the RPM solution is deployed across three domains, HDOs must recognize that the responsibility for risk management remains with the HDO. Risk mitigation may be achieved through tools or practices, where privacy and security measures are applied as appropriate in each of the domains. HDOs may find that deploying privacy and security tools to the patient home involves challenges, and that, therefore an HDO may collaborate with the telehealth platform provider

NIST SP 1800-30B: Securing Telehealth Remote Patient Monitoring Ecosystem

33

to provide adequate education and awareness training to patients. Training may address appropriate use of the equipment that is sent to the patient home, awareness that patient data are involved, and that the patient needs to assure that data are shared only with authorized individuals.

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

For this practice guide, the telehealth platform provider is a third-party entity distinct from the patient and the HDO. Telehealth platform providers should implement an adequate control environment that enables the telehealth platform provider to collaborate with HDOs in delivering RPM solutions. The scope of this practice guide does not discuss all controls that a telehealth platform provider should deploy. Rather, this practice guide focuses on controls that are deployed in the HDO. The telehealth platform provider is a separate entity and should ensure that adequate controls are implemented in its environment. Further, telehealth platform providers must ensure that equipment deployed to the patient home includes appropriate safeguards.

NIST SP 1800-30B: Securing Telehealth Remote Patient Monitoring Ecosystem

34

Table 3-7 Products and Technologies

Component/ Capability This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

telehealth platform provider

Product

Function

Accuhealth Evelyn

Vivify Pathways Home

Vivify Pathways Care Team Portal

Provides role-based user access control. Performs asset management for the provisioned devices. Transmits health information to the platform. Connects patients and physicians.

NIST Cybersecurity Framework Domain and Privacy Framework Subcategories ID.AM-1 ID.AM-2 ID.AM-4 ID.AM-5 PR.AC-1 PR.AC-4 PR.AC-5 PR.AC-6 PR.AC-7 PR.DS-1 PR.DS-2 PR.DS-3 PR.DS-4 PR.DS-6 PR.PT-1 PR.PT-3 PR.PT-4

patient home telehealth platform provider

ID.IM-P1 ID.IM-P2 ID.IM-P7 PR.AC-P1 PR.AC-P4 PR.AC-P5 PR.AC-P6 PR.DS-P1 PR.DS-P2 PR.DS-P3 PR.PT-P2 PR.PT-P3

NIST SP 1800-30B: Securing Telehealth Remote Patient Monitoring Ecosystem

35

Component/ Capability

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

risk assessment controls

Product

Function

Tenable.sc Vulnerability Management Version 5.13.0 with Nessus

 

identity Active Directory management, (AD) authentication, and access control

Cisco Firepower Version 6.3.0

    Cisco Umbrella

Provides on-premises centralized vulnerability management with multiple scanners. Provides vulnerability prioritization. Provides risk scores. Authenticates and authorizes users and computers in the domain. Authenticates and authorizes to multiple applications within the environment. Provides a Firepower management console (FMC) used for Firepower Threat Defense (FTD). Provides centralized control over network and communication. Provides network visibility. Provides intrusion prevention. Provides network segmentation. Provides policy-based network protection. Provides domain name system (DNS) and internet protocol (IP) layer security.

NIST SP 1800-30B: Securing Telehealth Remote Patient Monitoring Ecosystem

NIST Cybersecurity Framework Domain and Privacy Framework Subcategories ID.RA-5

HDO

ID.RA-P4

PR.AC-1 PR.AC-4

HDO

PR.AC-P1 PR.AC-P4 PR.AC-5 PR.PT-4 DE.AE-2 DE.CM-1 DE.CM-4 DE.CM-5

HDO

PR.AC-P5 PR.PT-P3

DE.CM-4 DE.CM-5

HDO

36

Component/ Capability

Product

Function

 This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

 Cisco Stealthwatch Version 7.0.0

Onclave Zero Trust Platform Version 1.1.0

NIST Cybersecurity Framework Domain and Privacy Framework Subcategories

Provides content/application filtering. Provides advanced malware protection (AMP). Provides insight into who and what is on the network. Provides network analysis through machine learning and global threat intelligence. Provides malware detection for encrypted traffic.

PR.DS-5 PR.PT-4 DE.AE-1 DE.CM-1 DE.CM-4 DE.CM-5

Leverages blockchain technology to manage valid endpoints.

PR.AC-1 PR.AC-3 PR.AC-4 PR.PT-4

HDO

PR.DS-P5 PR.PT-P3 telehealth platform provider

PR.AC-P1 PR.AC-P3 PR.AC-P4 PR.PT-P3 data security

Accuhealth

Vivify Health

Ensures that data-in-transit are protected. Ensures that data-at-rest are protected.

PR.DS-1 PR.DS-2 PR.DS-3 PR.DS-P1 PR.DS-P2 PR.DS-P3

NIST SP 1800-30B: Securing Telehealth Remote Patient Monitoring Ecosystem

patient home telehealth platform provider HDO

37

Component/ Capability

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

Product

Function

Onclave Secure IoT Bridge Version 1.1.0

Onclave Secure IoT Gateway Version 1.1.0

anomalies and events and security continuous monitoring

LogRhythmXDR Version 7.4.9

 

LogRhythm NetworkXDR Version 4.0.2

NIST Cybersecurity Framework Domain and Privacy Framework Subcategories

Provides trusted and secure communication between Onclave gateways. Establishes encrypted layer 2 secure tunnels between Onclave bridges and gateways.

PR.DS-2 PR.DS-P2

telehealth platform provider

Forms the basis of a cryptographically secure enclave. Establishes encrypted layer 2 secure tunnels between trusted gateways.

PR.AC-5 PR.DS-5

patient home

PR.AC-P5 PR.DS-P5

telehealth platform provider

ID.RA-5 PR.PT-1 DE.AE-1 DE.AE-2 DE.CM-7

HDO

Aggregates log files. Performs behavioral analytics. Monitors for unauthorized personnel, connections, devices, and software. Provides dashboards with the analytic results.

ID.RA-P4 CT.DM-P8

4 Architecture This practice guide implements a representative RPM solution as a distributed architecture. The solution deployed components across three domains that consist of the patient home, the telehealth platform provider, and the HDO. The patient home is the environment in which the patient lives and uses RPM components that include biometric monitoring devices, devices that the patient uses to communicate with their care team, and devices that the patient operates for personal use. This practice guide incorporates cloud-hosted telehealth platform providers within the architecture. The telehealth

NIST SP 1800-30B: Securing Telehealth Remote Patient Monitoring Ecosystem

38

platform provider maintains components that include virtual or physical components with servers to manage, maintain, and receive data communications from either the patient home or the HDO. The HDO maintains its own environment and includes components such as workstations and clinical systems to receive and interpret patient data and record patient interactions in an electronic health record (EHR) system.

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

Figure 4-1 illustrates a high-level RPM distributed architecture. The depicted architecture notes two primary paths by which network communications traverse. Path 1 shows biometric devices communicating with the telehealth platform provider whereas Path 2 shows the use of a mobile app. The mobile app operates on an interface device (i.e., a provisioned tablet). For Path 2, patients use the tablet to collect data from the biometric devices. Path 2 does not involve data transfer between the biometric device to the telehealth platform provider directly. Rather, patients collect biometric data with the tablet. Patients use the tablet for communications with data exchanges between the patient home and the telehealth platform provider. Figure 4-1 RPM Architecture

NIST SP 1800-30B: Securing Telehealth Remote Patient Monitoring Ecosystem

39

4.1 Layering the Architecture The NCCoE healthcare lab stratified the distributed architecture with three layers: business, security, and infrastructure. The business layer focuses on functional capabilities that include biometric readings and patient interactions. The security layer conceptually describes how the NCCoE lab implements security capabilities. The NCCoE also implements an infrastructure layer that represents the network and communications environment. This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

The layers intersect each of the three domains. The patient home domain implements the business layer by using the biometric devices and interface device(s) that capture and relay biometric data from the patient and allow the patient to communicate with the clinical care team, respectively. The patient home may include a security layer component that segregates network traffic between the RPM components and personally-owned devices when the RPM devices use the same network infrastructure (e.g., over Wi-Fi) as the personally-owned devices. When devices operate and communicate over Wi-Fi, the infrastructure layer would consist of Wi-Fi access points, routers, and switches that the patient operates. The telehealth platform provider domain also implements three layers. The business layer consists of services that facilitate handling patient data and web- or audioconferencing capabilities. The security layer consists of components used to secure the environment, such as authentication mechanisms, certificate management systems, and security logging capabilities. The infrastructure layer consists of network and server components that may be implemented as cloud services. Practitioners should note that this practice guide does not go into significant detail regarding security or infrastructure layer configurations for telehealth platform providers. As noted in this practice guide’s list of assumptions, it is assumed that telehealth platform providers have adequate privacy and security controls. These controls would align with the layer concept. HDOs should evaluate telehealth platform providers to determine control adequacy. The HDO domain implements the business layer with applications and clinical systems used to support the RPM program. The security layer represents security capability deployment, which includes authentication mechanisms, network monitoring capabilities, and vulnerability scanning for example. The HDO implements the infrastructure layer with fundamental IT services such as Active Directory (AD), DNS, and networking devices. Figure 4-2 depicts a high-level view of the three layers intersecting each domain of these components and how we approached implementing them in the lab environment.

NIST SP 1800-30B: Securing Telehealth Remote Patient Monitoring Ecosystem

40

Figure 4-2 Architecture Layers

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

4.2 High-Level Architecture Communications Pathways This practice guide describes an architecture that considers six different communications paths among the patient home, telehealth platform provider, and HDO. Figure 4-3, RPM Communications Paths, shows the different paths labeled A through F. The different communications paths represent the varying modes by which the patient shares data with the clinician. Each path leads to the telehealth platform provider who receives the data and presents the data in an HDO-facing application. The clinician accesses data presented within an HDO-facing application via an app or application.

4.2.1

Cellular Data Pathways

The following communications pathways describe how patients use devices that are preconfigured with cellular data services. Telehealth platform providers may provision devices with cellular data capability to support ease of use and connectivity assurance and to ensure that the device may not be reachable by an untrusted internet connection (e.g., an arbitrary Wi-Fi hot spot). Path A assumes that the biometric device has cellular communications. The telehealth platform provider deploys the biometric device with a preconfigured subscriber identity module, commonly referred to as a subscriber identity module (SIM) card. Option A does not include an RPM interface, such as a mobile

NIST SP 1800-30B: Securing Telehealth Remote Patient Monitoring Ecosystem

41

device that may be a laptop, cellular phone, or tablet. The biometric device sends data over cellular data networks, which then route the data to the telehealth platform provider. The telehealth platform provider receives the data and displays it for clinicians to view through a portal or dashboard application. The clinician accesses the data through a clinician-facing app or application.

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

Path B assumes that the telehealth platform provider has deployed a biometric device and an RPM interface to the patient home. The RPM interface may be a mobile device such as a cellular phone or tablet. For this path, the biometric device forwards data to the RPM interface via Bluetooth. The RPM interface would include a SIM card that enables cellular data communication to the telehealth platform provider. The RPM interface would be deployed with an app to be used by the patient. The app would include an interface that allows the patient to forward the data to the telehealth platform provider.

4.2.2

Broadband Pathways

Telehealth platform providers may provide devices that leverage broadband internet connectivity provisioned at the patient home. Devices may use Wi-Fi or other communications protocols. Devices may transmit data that traverse a patient-provided internet router. The following pathways describe how data may flow when internet broadband is available. Path C assumes that the telehealth platform provider has deployed a biometric device and an RPM interface to the patient home. The dataflow within the patient home domain is the same as Path B. However, rather than cellular communication, the RPM interface communicates with the telehealth platform provider via a broadband connection provided by the patient. Path D has the same dataflow as Path C; however, external network transmissions traverse an add-on security device such as a Layer 2 over Layer 3 gateway. Path E is like Path A; however, rather than cellular data, the path leverages a patient home broadband connection traversing an add-on security device such as a Layer 2 over Layer 3 gateway. Path F is like Paths A and E. Path F leverages a patient home broadband connection; however, no other gateway is used. Data are sent directly to the telehealth platform provider over the public internet.

NIST SP 1800-30B: Securing Telehealth Remote Patient Monitoring Ecosystem

42

Figure 4-3 RPM Communications Paths

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

4.3 Data and Process Flows To gain a high-level understanding of how RPM programs operate, this practice guide evaluates two use cases: diabetes and cardiac and pulmonary rehabilitation. The World Health Organization defines diabetes as “a chronic, metabolic disease characterized by elevated levels of blood glucose (or blood sugar), which leads over time to serious damage to the heart, blood vessels, eyes, kidneys, and nerves” [16]. A diabetes RPM program could be beneficial in identifying when a patient’s blood glucose levels are higher/lower than normal. Ensuring that a patient’s blood glucose levels remain in a normal range helps prevent long-term complications that diabetes could cause [17]. Patients may receive biometric devices such as glucometers, blood pressure monitors, weight scales, and activity trackers. These biometric devices may be enabled with Bluetooth, Wi-Fi, or cellular data communications capabilities that allow patients to share biometric data with physicians. Physicians may continuously monitor patients’ biometric data to identify and prevent a potential problem from occurring.

NIST SP 1800-30B: Securing Telehealth Remote Patient Monitoring Ecosystem

43

HDOs may enroll patients with chronic heart or lung conditions such as chronic obstructive pulmonary disease or coronary heart disease into cardiac and pulmonary RPM rehabilitation programs. These programs help patients return to a normal life and reduce other risk factors such as high blood pressure, high blood cholesterol, and stress [18], [19].

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

Telehealth platform providers implement solutions by using biometric devices, services, and applications. While telehealth platform providers may develop and maintain services and applications, they collaborate with manufacturers to procure and manage biometric devices. Conceptually, the device manufacturer operates as an extension of the telehealth platform provider when delivering RPM solutions to patients. As noted in Section 4.2, High-Level Architecture Communications Pathways, practitioners may implement RPM ecosystems where data communications involve different communications protocols or paths. This practice guide examines two distinct dataflows. The first dataflow begins when the patient transmits data from the biometric device. The biometric device sends data to the device manufacturer. The telehealth platform provider retrieves the data and presents the data through an HDO-facing application. The clinician views the data from an app or application that interfaces with the patient data residing in the telehealth platform provider HDO-facing application. The second dataflow begins when the patient transmits the data from the biometric device. A field gateway device, such as a mobile device that may be a tablet, mobile phone, or laptop, pulls the data from the biometric device. The patient uses the field gateway device to transport the data to the telehealth platform provider. The telehealth platform provider receives the data and presents it through an HDO-facing application. The clinician views the data from an app or application that interfaces with the patient data residing in the telehealth platform provider HDO-facing application. Figure 4-4 depicts the first dataflow sequence. This dataflow sequence demonstrates an RPM implementation that uses device vendor platforms to transmit data from a patient’s home to the telehealth platform provider. A patient begins the process by interfacing with the biometric device provided by the third-party platform, which in turn gathers the required medical readings. Once the device gathers the desired readings, the device transmits and stores the data to the device vendor’s local storage server. The third-party platform connects to the vendor’s storage server and pulls that data into its own local storage server. The platform then evaluates the received data and creates correlations among the retrieved data, the associated patient, and the primary care provider. If the platform identifies any areas of concern (such as high blood glucose readings for a diabetes use case) while evaluating the data, the platform sends an alert to the patient’s primary care provider for immediate action. Otherwise, the primary care provider will connect to the third-party platform’s web server to view the patient’s data on a dashboard. The physician/clinician will evaluate the data, modify the patient’s care plan, update the patient’s EHR, and contact the patient via video or audio call to update them on their new care plan.

NIST SP 1800-30B: Securing Telehealth Remote Patient Monitoring Ecosystem

44

Figure 4-4 RPM Dataflow Option 1

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

Figure 4-5 depicts the second dataflow sequence. In this dataflow sequence, a patient begins the process by interfacing with the biometric device provided by the telehealth platform provider, which in turn collects the required medical readings. Once the data are collected, the device transmits the data to the mobile device. The patient interacts with the mobile device to answer survey questions associated with their program, providing a clinician more insight on the patient’s health. The patient uses the mobile device to collect data from all biometric devices associated with their RPM regimen. The patient then uses the mobile device to transmit the biometric device data and survey results. The mobile device pushes the grouped data to the telehealth platform provider. The telehealth platform provider presents the data to the primary care provider. The clinician connects to the telehealth platform provider’s web server to view the patient’s data on a dashboard. The clinician evaluates the data and may update the patient’s care plan. Then, the clinician may update the patient’s EHR and contact the patient via a mobile device to update them on their new care plan.

NIST SP 1800-30B: Securing Telehealth Remote Patient Monitoring Ecosystem

45

Figure 4-5 RPM Dataflow Option 2

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

4.4 Security Capabilities The project team implemented a lab environment that represented the three domains described in Section 4, Architecture. When building the HDO environment, the team built upon the zoned network architecture described in NIST SP 1800-8, Securing Wireless Infusion Pumps in Healthcare Delivery Organizations [20]. The team used the network zoning approach as a baseline for the RPM ecosystem infrastructure. On top of the baseline, the team selected relevant security capabilities for appropriate domains. The selected security capabilities are:     

telehealth platform provider risk assessment controls identity management, authentication, and access control data security anomalies and events and security continuous monitoring

NIST SP 1800-30B: Securing Telehealth Remote Patient Monitoring Ecosystem

46

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

HDOs bear risk when implementing RPM practices. The RPM environment is distributed across three domains and requires participation of the patient, the telehealth platform provider, and the HDO to assure that risks are adequately mitigated. This practice guide’s architecture describes deploying components in three domains, with threats and risks that may affect each domain distinctly. As organizations implement RPM solutions, they must include parties involved in managing the individual domains in recognizing and safeguarding against privacy and cybersecurity events that may occur within the respective domains. Practitioners will note that the security capability descriptions focus primarily on the HDO domain. Capabilities are deployed to other domains to the extent that the HDO may have influence. HDOs may not authoritatively determine the control environment implemented by the telehealth platform provider. HDOs may obtain assurance that similar controls are implemented by the telehealth platform provider before establishing the relationship with the provider. HDOs should establish questionnaires or audit approaches that they may use in evaluating third parties such as telehealth platform providers. HDOs and telehealth platform providers are subject to regulatory requirements to ensure patient privacy and cybersecurity. Telehealth platform providers are third parties that may implement security capabilities that do not necessarily use the tools standard to the HDO. Telehealth platform providers may provide services for many HDOs, and implementing the same tools for all HDOs may not be feasible from a technical perspective. Telehealth platform providers apply risk management approaches that are appropriate for their business model. While telehealth platform providers may manage risk by using different tools and techniques from the HDO, these providers should address the risk concerns for the HDO. Telehealth platform providers should apply similar measures, e.g., the NIST Cybersecurity Framework [3] and Risk Management Framework [4], that describe risk and control approaches. When evaluating telehealth platform providers, HDOs should review the privacy and security control policies and other documentation to ensure that the mitigation approaches that the telehealth platform provider implements are consistent with the HDO’s requirements. HDOs and telehealth platform providers may find difficulties when implementing security capabilities on the patient home domain. Patients may find complex controls or practices onerous, and, therefore, they may be less likely to participate in the RPM program. Telehealth platform providers may implement security capabilities for end-point devices, such as biometric sensors or mobile devices, that are part of the RPM program. HDOs, in collaboration with telehealth platform providers, may offer education and awareness material to discuss appropriate use of RPM-deployed equipment with the patient.

4.4.1

Telehealth Platform Provider

Telehealth platform providers are discussed in this practice guide as a security capability. HDOs implementing RPM programs will depend on telehealth platform providers to enable communications between patients and clinicians. Also, for this practice guide, telehealth platform providers configure,

NIST SP 1800-30B: Securing Telehealth Remote Patient Monitoring Ecosystem

47

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

manage, and maintain biometric devices and potentially other technology provided to the patient. HDOs engaging with telehealth platform providers to enable their RPM programs are responsible for ensuring that they apply due diligence and understand the privacy and security capabilities that the telehealth platform provider maintains. HDOs and partners with whom HDOs engage may be responsible for adhering to regulatory compliance and should ensure that HDOs have implemented measures that address compliance concerns as a baseline. Telehealth platform providers represent a third-party partner, and HDOs should evaluate their partners accordingly. In addition to safeguarding systems that aggregate patient information, telehealth platform providers are responsible for assuring that the biometric devices that are deployed to the patient home include adequate controls that mitigate privacy and security risk. Biometric devices have characteristics that are similar to Internet of Things (IoT) architecture. Telehealth platform providers should consider clinical efficacy of the devices as well as assure that devices do not pose privacy or cybersecurity harm to the patient home or the broader RPM ecosystem. Appendix E, Benefits of Device Cybersecurity Requirements, discusses challenges that may be found in biometric devices that may be regarded as IoT. Appendix Eʼs roots are founded in a new set of guidance focused on IoT security. NIST is developing several documents that discuss how IoT device manufacturers may incorporate privacy and security measures in products. Telehealth platform providers may review IoT Device Cybersecurity Guidance for the Federal Government: Establishing IoT Device Cybersecurity Requirements (NIST SP 800-213) [21]. While NIST SP 800-213 focuses on the federal government’s IoT deployment efforts, concepts found in the document may inform telehealth platform providers as they evolve their biometric device acquisition processes. The NIST Cybersecurity Framework includes risk assessment under the Identify Function. This practice guide implements tools for vulnerability management. The practice guide uses Tenable.sc with Nessus to perform vulnerability scanning and provide dashboard reports. Vulnerability scanning operates by applying signatures of known vulnerabilities. Components that operate within the HDO domain are subject to regular vulnerability scanning. As vulnerabilities are identified, patching or other mitigating approaches may be applied. Patches or updates to operating systems, apps, or applications may be applied as available.

4.4.2

Identity Management, Authentication, and Access Control

Identity management involves activities that discuss identity proofing and establishing credentials. Authentication for this practice guide provides the mechanisms that assure that authorized entities access the system after telehealth platform providers and HDOs establish respective credentials. Practitioners should refer to NIST SP 1800-24 (reference Section 5.3.3), Securing Picture Archiving and Communication System (PACS) [14], which provides more in-depth discussion on identity management and access control. While that practice guide uses different tools and addresses a clinical practice

NIST SP 1800-30B: Securing Telehealth Remote Patient Monitoring Ecosystem

48

different from RPM, concepts regarding identity management and authentication are relevant for this practice guide.

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

This practice guide builds upon a network zoning concept that was discussed in NIST SP 1800-8, Securing Wireless Infusion Pumps in Healthcare Delivery Organizations [20]. Figure 4-6 depicts the lab environment built for this practice guide. The diagram splits the infrastructure between the NCCoE and the RPM lab, with the latter representing the configured simulated environments for this practice guide. Focusing on the HDO cloud depiction, this practice guide simulates the HDO environment that is made up of enterprise services, health information system (HIS) services, remote services, databases, clinical workstations, and security services virtual local area networks (VLANs). Figure 4-6 Network Segmentation and VLAN Within the RPM Lab

The practice guide extends the network zoning concept between the patient home and the telehealth platform provider. Biometric devices in the patient home using a Wi-Fi communications pathway that traverses a patient-provided broadband connection are secured using a layer 2 over layer 3 solution. In a simulated cloud environment, engineers deployed the layer 2 over layer 3 solution between zones that represent the patient home and a telehealth platform provider. The layer 2 over layer 3 solution segmented the biometric devices from the patient home network into a secured enclave. The enclave assures that network traffic from the patient home is not introduced or have visibility to the biometric devices. The layer 2 over layer 3 solution secures the data-in-transit communications between the

NIST SP 1800-30B: Securing Telehealth Remote Patient Monitoring Ecosystem

49

patient home and telehealth platform provider domains respectively and adopts an approach that is consistent with concepts described in NIST SP 800-207, Zero Trust Architecture [22].

4.4.3

Data Security

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

This practice guide examines challenges associated with data loss and data alteration. Communications initiate from the patient home, traversing a public communications channel, and are made accessible to clinicians via internet connectivity. This practice guide addresses the need to provide end-to-end data protection as a vital requirement to ensure RPM viability. Network sessions are encrypted. Telehealth platform providers implement data security as they manage biometric devices and the dataflow between the patient home and solutions hosted by the telehealth platform provider. Stored data are protected through encryption. The project team examined dataflows and applied a privacy risk assessment that analyzed communications between the implemented components and identified how data-in-transit security controls are implemented.

4.4.4

Anomalies and Events and Security Continuous Monitoring

Managing anomalies and events and performing security continuous monitoring provides a proactive, real-time measure to determine that threats and vulnerabilities are appropriately recognized and mitigated within HDO environments. This practice guide implements several controls that address managing anomalies and events and performing security continuous monitoring. Security engineers require tools and processes to manage anomalies and events that include applying cyber threat intelligence (CTI), collecting and managing log information, and applying behavioral analytics. NIST describes CTI in NIST SP 800-150, Guide to Cyber Threat Information Sharing [23]. NIST provides additional detail regarding security continuous monitoring in NIST SP 800-137 [24].

4.5 Final Architecture The project team built a reference architecture to include two communications pathways for biometric devices. In the first case, biometric devices in the patient home communicated to the telehealth platform provider over cellular data communications. The team built an architecture that addressed communications pathways A and B that were described in Section 4.2, High-Level Architecture Communications Pathways. In the second case, biometric devices communicated to a mobile device, and the mobile device leveraged the patient home Wi-Fi infrastructure. Mobile device communications to the telehealth platform provider are secured by a layer 2 over layer 3 solution through Onclave’s Secure IoT platform. Layer 2 over Layer 3 concepts are further described in Appendix F. This scenario aligns with pathway D described in Section 4.2. Figure 4-7 depicts the final architecture of the lab environment. The two telehealth platform providers, Accuhealth and Vivify, provided cloud-hosted solutions, with biometric devices deployed in respective home environments, described as Home One and Home Two. Biometric devices were provisioned and

NIST SP 1800-30B: Securing Telehealth Remote Patient Monitoring Ecosystem

50

managed by the telehealth platform providers, with data communications over cellular data. A Home Three environment was provisioned to deploy biometric devices that would communicate over Wi-Fi. The architecture includes a telehealth platform provider hosted in a simulated cloud environment. Engineers implemented a layer 2 over layer 3 solution between Home 3 and the simulated cloud environment.

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

The architecture also includes an HDO environment with six network zones: Remote Services, Clinical Workstations, Enterprise Services, Databases, HIS Services, and Security Services. Figure 4-7 Final Architecture

5 Security and Privacy Characteristic Analysis The purpose of the security and privacy characteristic analysis is to understand the extent to which the project meets its objective of demonstrating the privacy and security capabilities described in the reference architecture in Section 4. In addition, it seeks to understand the security and privacy benefits and drawbacks of the example solution.

NIST SP 1800-30B: Securing Telehealth Remote Patient Monitoring Ecosystem

51

5.1 Assumptions and Limitations The security characteristic analysis has the following limitations:

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

It is neither a comprehensive test of all security components nor a red-team exercise.

It cannot identify all weaknesses.

It does not include the lab infrastructure. It is assumed that devices are hardened. Testing these devices would reveal only weaknesses in implementation that would not be relevant to those adopting this reference architecture.

HDOs and telehealth platform providers implement an array of risk mitigation approaches that extend beyond what is discussed in this document. The broader array of controls consists of organizational structures, policies and procedures, and tools to support enterprise privacy and cybersecurity programs that this practice guide refers to as a set of pervasive controls.

HDOs and telehealth platform providers evaluate privacy risks throughout the RPM solution ecosystem and coordinate risk management roles and expectations with organizations that are part of the RPM solution.

5.2 Pervasive Controls NIST SP 1800-24, Securing Picture Archiving and Communication System (PACS) [14], described the use of controls that were termed “pervasive”. Subsequent practice guides such as this RPM practice guide discuss implementing controls that narrowly apply to the practice guide’s lab construction. Notwithstanding, HDOs and telehealth platform providers are enterprise organizations that may face a broader set of risks, including regulatory requirements, that extend beyond the narrow topic. The pervasive control concept assumes that HDOs and telehealth platform providers have implemented a comprehensive control set to address their risk and regulatory obligation. For example, onboarding workforce members may involve identity proofing and creating and managing accounts and credentials. Organizations need to perform these activities to appropriately implement an enterprise risk management program. The requirement is not specific to RPM programs. These functions should be established prior to implementing an RPM program. Other controls, such as performing asset management, having incident response teams, and establishing incident response programs, should also be pervasive across the enterprise. Another example is asset management. Asset management is a critical control that should be implemented by telehealth platform providers. Telehealth platform providers should maintain accurate inventories and manage configuration settings, patching, updates, and the overall life cycle for devices that are deployed to the patient home. While this is a requirement, the project team partnered with multiple telehealth platform providers. The team did not deploy security or privacy capabilities to the telehealth platform providers. Rather, it relied upon telehealth platform providers to implement an

NIST SP 1800-30B: Securing Telehealth Remote Patient Monitoring Ecosystem

52

adequate and appropriate set of pervasive controls for their environment and for the services that they provide.

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

The NIST Cybersecurity Framework [3] describes cybersecurity activities and outcomes that organizations should achieve for establishing or improving enterprise security programs. These activities and outcomes are articulated in the Subcategories of the Cybersecurity Framework Core. The Cybersecurity Framework provides the basis for pervasive controls, whereas this practice guide highlights implementation of selected controls. Readers should not regard the selected controls as the only controls that an HDO must implement. The selected controls that are described in this practice guide are a small subset of controls that HDOs and telehealth platform providers should implement. This practice guide’s descriptions of controls indicate how the selected controls were implemented in the lab environment.

5.3 Telehealth Platform Providers Telehealth platform providers address several controls for the RPM solution. Telehealth platform providers configure, maintain, and manage devices that are deployed to the patient home domain. Telehealth platform providers provision devices to patients who have been enrolled in an RPM program by their HDO. Telehealth platform providers perform asset management for the provisioned devices and, thus, address ID.AM-1, ID.AM-2, ID.AM-4, ID.AM-5, ID.IM-P1, ID.IM-P2, and ID.IM-P7. Telehealth platform providers are responsible for addressing ID.RA-1. Telehealth platform providers authenticate sessions based on the device identifier. When patients send or transfer data from biometric devices, data are routed to the telehealth platform provider. The telehealth platform provider receives the data and makes it available to clinicians and system users via a portal. Portals use unique identifiers for credentials (e.g., username/password) and role-based access control and ensure that connections to the portal are protected by using Transport Layer Security (TLS) 1.2. For this practice guide, telehealth platform providers provisioned two classes of biometric devices: those that used cellular data communications and those that used the patient home-provided Wi-Fi network. In the first category, devices were explicitly not permitted to access Wi-Fi networks. Removing Wi-Fi capability separated RPM communication from network traffic that may have been present in the patient home domain. In the second case that deployed biometric devices that included Wi-Fi capability, those devices leveraged the patient home Wi-Fi environment and used a layer 2 over layer 3 solution to secure connectivity between the RPM devices and the telehealth platform provider. For biometric devices that focused on cellular data communications, the project team used devices that were equipped to communicate over 4G Long-Term Evolution (LTE), which uses asymmetric encryption between the device and the cellular tower [25]. Further investigation in data-in-transit protection was not determined in this practice guide.

NIST SP 1800-30B: Securing Telehealth Remote Patient Monitoring Ecosystem

53

The second case included biometric devices leveraged in the patient home Wi-Fi environment. Network sessions were secured using another product that provided in-transit protection using a layer 2 over layer 3 solution. The project team deployed dedicated gateway devices used to implement a network infrastructure that was consistent with NIST SP 800-207, Zero Trust Architecture [22].

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

The telehealth platform provider addressed PR.AC-1, PR.AC-4, PR.DS-1, PR.DS-2, PR.DS-4, PR.DS-6, PR.PT-1, PR.PT-3, PR.PT-4, PR.AC-P1, PR.AC-P4, PR.DS-P1, PR.DS-P2, PR.DS-P4, PR.DS-P6, CT.DM-P8, PR.PT-P2, and PR.PT-P3. The project team implemented telehealth platform provider services with Accuhealth and Vivify Health.

5.4 Risk Assessment (ID.RA and ID.RA-P) This practice guide implemented tools that address elements of ID.RA-5 (threats, vulnerabilities, likelihoods, and impacts are used to determine risk) and ID.RA-P4. The project team implemented Tenable.sc to address vulnerability management. Tenable includes vulnerability scanning and dashboards that display identified vulnerabilities with scoring and other metrics that enable security engineers to prioritize. Telehealth platform providers have separate infrastructures and organizational structures that require similar approaches. Telehealth platform providers may host their services with various implementations and may deploy similar solutions for their environments.

5.5 Identity Management, Authentication, and Access Control (PR.AC and PR.AC-P) Protective Technology (PR.PT-P) The engineers regarded many of the identity management Subcategories as part of a set of pervasive controls that have been discussed in NIST SP 1800-24, Securing Picture Archiving and Communication System (PACS) [14]. HDOs and telehealth platform providers should apply similar solutions to address managing human, device, and system identities. Sample solutions are provided in NIST SP 1800-24. Extending the network zoning concepts that were described in NIST SP 1800-8, Securing Wireless Infusion Pumps in Healthcare Delivery Organizations [20], the project team implemented VLANs with firewall feature sets by using Cisco Firepower Threat Defense (FTD). This practice guide addresses PR.AC5 by implementing VLANs that represent network zones found within an HDO. Telehealth platform providers may implement similar measures within their infrastructures. The NIST Cybersecurity Framework implements identity management, authentication, and access control under the Protect Function by using the PR.AC Category. Within the HDO, the engineers implemented PR.AC-5 by using Cisco FTD to establish network zones as a set of VLANs. The network zones assure that components from each zone do not have implicit trust, and, thus, compromises on end points found in one zone are limited in their ability to affect devices that operate in other zones.

NIST SP 1800-30B: Securing Telehealth Remote Patient Monitoring Ecosystem

54

The Onclave Secure IoT platform creates unique enclaves within the patient home and the telehealth platform provider with their own root of trust for implicit trust.

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

The engineers implemented three primary Cisco tools for the HDO environment: Cisco Firepower, Cisco Umbrella, and Cisco Stealthwatch. As noted, the project team used Firepower to create and manage VLANs within the environment. Cisco Firepower includes a central management dashboard that allowed security engineers to configure and manage other features within the Cisco suite of tools. Firepower also includes intrusion detection capability and visibility into network traffic and network analytics that enabled engineers to detect and analyze events, monitor the network, and detect malicious code and, thus, addressed DE.AE-2, DE.CM-1, and DE.CM-4. Cisco Firepower addressed PR.AC-5, PR.PT-4, PR.ACP5, and PR.PT-P3. The engineers implemented Cisco Umbrella for DNS and IP layer security and provided content and application filtering. Cisco Umbrella addressed DE.CM-4. The team also used Cisco Stealthwatch that implemented behavioral analytics capabilities and provided malware detection. Cisco Stealthwatch addressed PR.DS-5, PR.PT-4, DE.AE-1, DE.CM-1, PR.DS-P5, and PR.PT-P3. Within the HDO domain, engineers implemented an AD to establish user accounts. AD credentials provided engineers with authentication for several components deployed in the lab. The lab’s AD implementation addresses PR.AC-1, PR.AC-4, PR.AC-P1, and PR.AC-P4. The telehealth platform provider assures that PR.AC-5, PR.AC-6, PR.AC-7, PR.AC-P5, and PR.AC-P6 are met by managing components that are deployed to the patient home. Components that are deployed by the telehealth platform provider are fully managed devices that have been preconfigured and distributed by Accuhealth. The RPM components that Accuhealth provided for the patient home use a cellular communication pathway where unauthorized individuals may not remove or alter SIM cards. The cellular data communication pathway assures that the RPM components are segregated from untrusted devices that may operate in the patient home and, thus, implements PR.AC-5 and PR.AC-P5. This practice guide also simulated a use case where a telehealth platform provider provides RPM components that use patient-provided broadband. The simulated test case implements Vivify components; however, it does not reflect how Vivify hosts its services. Biometric devices communicate with an interface device (e.g., the tablet). The simulated environment includes centralized configuration management for interface devices such as the tablet. Management prevents end users from modifying tablet configuration settings or installing unauthorized software. In this use case, biometric devices leverage the patient home Wi-Fi. Engineers secured the devices by leveraging a layer 2 over layer 3 solution to create a secure enclave. The solution segments the biometric devices from the patient home network, with only the biometric devices enabled to communicate over the secure enclave. The secure enclave solution included gateways implemented at the patient home and the simulated telehealth provider. The secure enclave solution supports PR.AC-1, PR.AC-3, PR.AC-4, PR.AC-5, and PR.PT-4. RPM-enrolled patients are predetermined by the HDO, and the telehealth platform provider provisions RPM components to an established, known set of patients. HDOs enrolling patients in the RPM program partially addresses PR.AC-1 and PR.AC-P1. Clinicians identifying patients may be regarded as performing

NIST SP 1800-30B: Securing Telehealth Remote Patient Monitoring Ecosystem

55

an identity-proofing activity, whereas telehealth platform providers may complete PR.AC-1 and PR.ACP1 activities by creating accounts or records that relate to the patient and the RPM equipment that the patient receives. Patient-provided (e.g., “bring your own device”) biometric devices were excluded in this practice guide’s architecture. The telehealth platform provider manages patient home-deployed components and, thus, assures that PR.AC-6 and PR.AC-P6 are addressed. This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

For this practice guide, the telehealth platform provider manages components that it procured and configured. The telehealth platform provider configures the devices to include authenticators that enforce component authentication. For this practice guide, only biometric devices that are managed by telehealth platform providers are provisioned authenticators. This implements PR.AC-7 and PR.AC-P6. Patient homes may include other devices, such as personally-owned devices, that are not a part of the RPM ecosystem. Devices that are not managed by telehealth platform providers do not have authentication credentials for the RPM solution. One should note that this practice guide simulated a telehealth platform provider when exploring biometric devices that communicate over broadband.

5.6 Data Security (PR.DS and PR.DS-P) This practice guide implemented PR.DS-2 and PR.DS-P2 to ensure that data-in-transit are protected. HDOs connecting to cloud-hosted consoles used TLS 1.2 [26]. The telehealth platform provider assured implementation of PR.DS-3 and PR.DS-P3 for RPM biometric devices deployed to the patient home. For biometric devices that communicate over broadband, the project team secured network sessions using a layer 2 over layer 3 solution that is established using the Onclave Secure IoT platform. The solution segmented biometric devices and their communication from the patient home network. Network sessions between the patient home and the simulated telehealth platform provider used TLS 1.2. The Onclave Secure IoT platform used a key management mechanism that is consistent with guidance from NIST SP 800-57 Part 1, Revision 5, Recommendation for Key Management: Part 1–General [27]. The Onclave IoT Platform solution secured sessions using a private blockchain. Data-in-transit used Advanced Encryption Standard (AES)-256 encryption [28]. This addresses PR-DS-2 and PR-DS.5 for communications between the patient home and the simulated telehealth platform provider. Accuhealth and Vivify Health use AES-256 encryption [28] for data-at-rest and address PR.DS-1 and PR.DS-P1.

5.7 Anomalies and Events, Security Continuous Monitoring (DE.AE, DE.CM), and Data Processing Management (CT.DM-P) The project team implemented LogRhythmXDR as a security incident and event management (SIEM) tool. End-point devices that include servers and network infrastructure components generate log data that were aggregated in the SIEM tool for analysis. LogRhythm included two components:

NIST SP 1800-30B: Securing Telehealth Remote Patient Monitoring Ecosystem

56

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

LogRhythmXDR and LogRhythm NetworkXDR. SIEM capabilities provide security engineers a baseline of network operations and allow security engineers to determine expected dataflows for users and systems. Engineers can detect events and analyze potential threats. LogRhythmXDR, therefore, is a SIEM that addresses NIST Cybersecurity Framework Subcategories ID.RA-5, PR.PT-1, DE.AE-1, DE.AE-2, ID.RAP4, and CT.DM-P8. LogRhythm NetworkXDR provides capabilities that assure that the network is monitored for potential cybersecurity threats. It also provides assurance that unauthorized mobile code is detected and, thus, addresses DE.CM-7. This practice guide assures implementation of a network monitoring capability based on regular log collection and applies the SIEM analytics and automated response capabilities. The project team implemented Cisco Firepower, Cisco Stealthwatch, and Cisco Umbrella, which detects malicious code, detects unauthorized mobile code and provides continuous network monitoring and analytics. Therefore, the Cisco suite addresses DE.CM-4 and DE.CM-5.

6 Functional Evaluation This practice guide uses the NIST Cybersecurity Framework. The Cybersecurity Framework includes Category and Subcategory concepts that allowed the project team to develop a reference architecture. The reference architecture reflects use cases and dataflows analyzed by the NCCoE. This practice guide aligns privacy and cybersecurity tools to Cybersecurity Framework Subcategories. The reference architecture depicts where tools were deployed.

6.1 RPM Functional Test Plan One aspect of our security evaluation involved assessing how well the reference design addresses the security characteristics that it was intended to support. The Cybersecurity Framework Categories and Subcategories were used to provide structure to the security assessment by consulting the specific sections of each standard that are cited in reference to a Subcategory. The cited sections provide validation points that the example solution would be expected to exhibit. Using the Cybersecurity Framework Subcategories as a basis for organizing our analysis allowed us to systematically consider how well the reference design supports the intended security characteristics.

6.1.1

RPM Functional Evaluation

Table 6-1 identifies the RPM functional evaluation addressed in the test plan and associated test cases. The evaluations are aligned with the basic architecture design and capability requirements from Section 4, Architecture.

NIST SP 1800-30B: Securing Telehealth Remote Patient Monitoring Ecosystem

57

Table 6-1 Functional Evaluation Requirements

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

Cybersecurity Framework Category

Relevant Identifier Requirement Cybersecurity Framework Subcategories

Domain

Test Case

asset management

ID.AM-1 ID.AM-5

home

RPM-1

CR-1

device management

telehealth platform provider risk assessment

ID.RA-1 ID.RA-4 ID.RA-5 ID.RA-6

CR-2

end-point vulnerability scanning

HDO

RPM-2

identity management, authentication, and access control

PR.AC-1 PR.AC-2 PR.AC-3 PR.AC-4 PR.AC-5 PR.AC-6

CR-3

role-based access

telehealth platform provider

RPM-3

CR-4

domain user authentication

HDO

RPM-4

CR-5

domain user authorization

HDO

RPM-4

CR-6

network segmentation

HDO

RPM-5

CR-7

access control policy

HDO

RPM-5

DE.CM-1 DE.CM-2 DE.CM-4 DE.CM-7 DE.CM-8

CR-8

malware protection

HDO

RPM-6

CR-9

anomaly detection

HDO

RPM-7

CR-10

LogRhythm

HDO

RPM-8

CR-11

LogRhythm

HDO

RPM-9

PR.DS-2

CR-12

data-in-transit is protected.

home

RPM-10

security continuous monitoring

data security

telehealth platform provider N/A

N/A

CR-13

business workflow

NIST SP 1800-30B: Securing Telehealth Remote Patient Monitoring Ecosystem

home

RPM-11

58

Cybersecurity Framework Category

Relevant Identifier Requirement Cybersecurity Framework Subcategories

Domain

Test Case

telehealth platform provider This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

HDO

6.1.2

Test Case: RPM-1

Cybersecurity Framework Category Testable Requirement(s) Description Preconditions

Procedure

Asset Management (CR-1) device management Demonstrate the ability to verify that provisioned devices are associated with the intended patient who has enrolled in an RPM program.  A doctor-level Accuhealth account has been provisioned.  Accuhealth RPM devices have been provisioned and delivered, including the following (obfuscated serial number): o blood pressure monitor (1234567) o blood glucose monitoring system (22334455) o digital scale (987654)  Accuhealth has enrolled sample patients and associated them with the RPM devices listed above, including: o Regina Houston (1234567) o Regina Houston (987654) o Janelle Kouma (22334455) Verify the patient/device association in the Accuhealth system. 1. Log in to the Accuhealth platform with the doctor-level user account. 2. Click Patient Details. 3. Under Select Patient, select Regina Houston. 4. Under Choose a view, select Profile. 5. Review the patient info for Regina Houston. 6. Navigate to Device Information. 7. Check if the Device ID field captures the device serial numbers, 1234567 and 987654, that are associated with Regina Houston. 8. Under Select Patient, select Janelle Kouma. 9. Review the patient information for Janelle Kouma. 10. Navigate to Device Information.

NIST SP 1800-30B: Securing Telehealth Remote Patient Monitoring Ecosystem

59

11. Check if the Device ID field captures the device serial number, 22334455, associated with Janelle Kouma.

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

Expected Results

Actual Results

Verify that data from the RPM devices are being sent to Accuhealth and associated with the correct patient. 12. For the following devices, turn on each device and follow the provided instructions to take a measurement: a. blood pressure monitor b. blood glucose monitoring system c. digital scale 13. Record the time and measurement readings as notes. 14. Log in to the Accuhealth platform with the doctor-level user account. 15. Click Patient Details. 16. Under Select Patient, select Regina Houston. 17. Under Choose a view, select Vitals. 18. Check if the blood pressure and weight measurements are present. 19. Under Select Patient, select Janelle Kouma. 20. Under Choose a view, select Vitals. 21. Check if the glucose measurement is present.  Accuhealth can provision the RPM devices and associate them to the intended patient enrolled in an RPM.  Accuhealth can capture the biometric measurements for the correct patient with the assigned RPM devices. Accuhealth provisioned an instance of its telehealth platform along with doctor-level accounts and sample patients associated with these accounts. We also received three RPM devices from Accuhealth: blood pressure monitor, blood glucose monitor, and digital scale. Accuhealth associated these RPM devices with the sample patients, which we verified by checking the Device ID information for each patient. Once the devices were received, we configured them and recorded sample measurements from each one. With the measurements taken, we logged in to the Accuhealth platform with the doctor-level account and viewed the Vitals information for each patient. As expected, the blood pressure and weight measurements were associated with Regina Houston’s patient record, and the blood glucose measurement was associated with Janelle Kouma’s patient record.

NIST SP 1800-30B: Securing Telehealth Remote Patient Monitoring Ecosystem

60

6.1.3

Test Case: RPM-2

Cybersecurity Framework Category Testable Requirement(s) Description This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

Preconditions

Procedure

Expected Results Actual Results

6.1.4

Risk Assessment (CR-2) end-point vulnerability scanning Demonstrate the ability to perform vulnerability scans on assets and view results in a dashboard format with risk-scoring evaluations.  Tenable.sc has been configured with the following: o organization o repository o security manager user account o scan zones for each VLAN o host discovery scan policy o basic network scan policy o active scans associated with each scan policy  A Nessus scanner has been deployed to the Security Services VLAN and is being managed by Tenable.sc.  The Nessus scanner has access to each scan zone. Perform scans and view the results. 1. Log in to Tenable.sc with the security manager user account. 2. Navigate to Scans > Active Scans. 3. Under HDO Asset Scan, click the run button (). 4. Wait for the HDO Asset Scan to finish. 5. Under HDO Network Scan, click the run button (). 6. Wait for the HDO Network Scan to finish. 7. Click Dashboard in the menu ribbon. 8. Check if the risk assessment results are displayed.  Tenable.sc and Nessus scan the HDO VLANs, identify vulnerabilities, and assign risk scores to discovered threats.  Tenable.sc displays risk assessment scan results in the dashboard. Using Tenable.sc, we ran a host discovery scan followed by a basic network scan. Once both scans were finished, we returned to the Tenable.sc dashboard and were able to view the results. The Nessus scanner was able to identify end points in the scan zones (VLANs) as well as potential vulnerabilities with associated risk scores.

Test Case: RPM-3

Cybersecurity Framework Category Testable Requirement(s)

Identity Management, Authentication, and Access Control (CR-3) role-based access

NIST SP 1800-30B: Securing Telehealth Remote Patient Monitoring Ecosystem

61

Description Preconditions

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

Procedure

Demonstrate the ability to limit and disable access to data by implementing role-based access control on the Vivify platform.  Vivify has provisioned a telehealth platform environment.  Vivify has provisioned an administrative user account.  Three test patients have been created in the Vivify platform: o Test Patient 1 o Test Patient 2 o Test Patient 3 Create a Clinical Level 1 user account, and test account privileges. 1. Log in to the Vivify platform by using the provisioned admin account. 2. Click Care Team in the menu bar. 3. Create a New User assigned to the Clinical Level 1 user group. 4. Access the Test Patient and add the new user into the Care Team for this patient. 5. Log out of the environment. 6. Log in to the environment with the user created in step 3. 7. Check if the account has read-only access to patient records associated with that clinician level. Create a Clinical Level 2 user account, and test account privileges. 8. Log in to the Vivify platform by using the provisioned admin account. 9. Click Care Team in the menu bar. 10. Create a New User assigned to the Clinical Level 2 and Clinical Level 1 user groups. 11. Access the Test Patient 2 and add the new user into the Care Team for this patient. 12. Log out of the environment. 13. Log in to the environment with the user created in step 10. 14. Check if the account has read and write access to patient records associated with that clinician level. Create a Clinical Level 3 user account, and test account privileges. 15. Log in to the Vivify platform by using the provisioned admin account. 16. Click Care Team in the menu bar. 17. Create a New User assigned to the Clinical Level 3, Clinical Level 2, and Clinical Level 1 user groups. 18. Log out of the environment. 19. Log in to the environment with the user created in step 17.

NIST SP 1800-30B: Securing Telehealth Remote Patient Monitoring Ecosystem

62

Expected Results

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

Actual Results

6.1.5

20. Check if the account has read and write privileges for all patient records.  A user account in the Clinical Level 1 group should be able to read only patient records assigned to that clinician.  A user account in the Clinical Level 2 should be able to read and write only to patient records assigned to that clinician.  A user account in the Clinical Level 3 should be able to read and write to all patient records. We started by logging in to the provisioned Vivify portal with our admin credentials and creating three new Care Team users, each with their own access levels. The first user was granted Clinical Level 1 and was added as Care Team of the test patient; the second was granted Clinical Levels 1 and 2 and was added as Care Team of the test patient; and the third was granted Clinical Levels 1 through 3. Then we logged in as each new user and tested their privileges. The first user was able to only view patient records that were assigned to her. The second user was able to view and modify patient records that associated only with those assigned to her. The third user was able to view and modify all patient records.

Test Case: RPM-4

Cybersecurity Framework Category Testable Requirement(s) Description Preconditions

Procedure

Identity Management, Authentication, and Access Control (CR-4) domain user authentication (CR-5) domain user authorization Demonstrate the ability to create new domain users and enforce restrictions on nonadmin users.  A Windows Server is deployed to the Enterprise Services VLAN.  The Windows Server has been configured as an Active Directory Domain Controller for the hdo.trpm domain.  A Windows workstation is deployed to the Enterprise Services VLAN and has been added to the hdo.trpm domain.  A Windows workstation is deployed to the Clinical Workstations VLAN and has been added to the hdo.trpm domain.  A Cisco Firepower access control policy rule has been created, allowing network traffic from the Clinical Workstations VLAN to the Enterprise Services VLAN.  The Cisco FTD appliance has been configured to provide Dynamic Host Configuration Protocol (DHCP) services for the Enterprise Services and Clinical Workstations VLANs. Create a nonadmin domain user.

NIST SP 1800-30B: Securing Telehealth Remote Patient Monitoring Ecosystem

63

1. 2. 3. 4. 5. 6. This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

Power on the Windows Server and log in. Open the Server Manager application. Navigate to Tools > Active Directory Users and Computers. Navigate to hdo.trpm > Users. Click Create a new user in the current container. Fill out the user’s information: a. First Name: User b. Last Name: Test c. User logon name: usertest 7. Click Next >. 8. Create a password for the user. 9. Uncheck User must change the password at next logon. 10. Click Next >. 11. Click Finish. 12. Right-click the user’s profile and select Properties. 13. Click Member Of. 14. Ensure that the user is a member of only Domain Users.

Create an admin domain user. 15. Navigate to hdo.trpm > Users. 16. Click Create a new user in the current container. 17. Fill out the user’s information: a. First Name: Admin b. Last Name: Test c. User logon name: admintest 18. Click Next >. 19. Create a password for the user. 20. Uncheck User must change the password at next logon. 21. Click Next >. 22. Click Finish. 23. Right-click the user’s profile and select Properties. 24. Click Member Of. 25. Click Add…. 26. Type Domain and click Check Names. 27. Select Domain Admins. 28. Click OK. 29. Click OK. Create network share folder. 30. Power on the Windows workstation in the Enterprise Services VLAN and log in with an administrator account. 31. Right-click the Windows Start Button.

NIST SP 1800-30B: Securing Telehealth Remote Patient Monitoring Ecosystem

64

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

32. Click Windows PowerShell (Admin). 33. Run the command ipconfig 34. Note the IP address (192.168.40.107). 35. Open the File Explorer application. 36. Navigate to This PC > Local Disc (C:). 37. Under Home, click New Folder. 38. Name the folder Share. 39. Right-click the new folder and select Properties. 40. Under Sharing, click Share…. 41. Click the drop-down and select Find people…. 42. Type Domain and click Check Names. 43. Select Domain Admins. 44. Click OK. 45. Click OK. 46. Click Share. 47. Click Done. 48. Create a new text document inside the Share folder and name it AccessTest. Test ability to access network share folder with nonadmin user. 49. Power on the Windows workstation in the Enterprise Services VLAN. 50. Log in with the nonadmin account, usertest, that was created in the previous steps. 51. Right-click the Windows Start Button. 52. Click Run. 53. Under Open, type \\192.168.40.107\Share. 54. Click OK. 55. Check if a network error is displayed, stating that the user does not have permission to access the network share folder. Test ability to access network share folder with admin user. 56. Log out of the nonadmin account. 57. Log in with the admin account, admintest, that was created in the previous steps. 58. Right-click the Windows Start Button. 59. Click Run. 60. Under Open, type \\192.168.40.107\Share. 61. Click OK. 62. Check if the network share folder is opened and the AccessTest text document is visible.

NIST SP 1800-30B: Securing Telehealth Remote Patient Monitoring Ecosystem

65

Expected Results

Actual Results This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

6.1.6

After the nonadmin and admin domain users have been created, they will be able to use their credentials to log in to computers within the domain.  Only the admin domain user will be able to access the network share folder. Once the user accounts were created and the network share folder was created and configured, we began by logging in to a domain computer with the nonadmin domain user. The user was able to successfully log in. Next, we tested the user’s ability to access the network share folder. The nonadmin domain user was not able to access the network share folder, receiving a network error stating that the user did not have the proper permissions. Finally, we were able to successfully log in to a domain computer with the admin domain user’s account. With this user, we were also able to successfully access the network share folder and view the files within. 

Test Case: RPM-5

Cybersecurity Framework Category Testable Requirement(s) Description Preconditions

Procedure

Identity Management, Authentication, and Access Control (CR-6) network segmentation (CR-7) access control policy Demonstrate the use of network segmentation and an access control policy to allow permitted traffic to selected network devices.  The Cisco FTD appliance’s interfaces are configured.  A Windows Server is deployed to the Clinical Workstations VLAN.  The Windows Server has been configured with a basic Internet Information Services (IIS) web service.  A Windows workstation is deployed to the Clinical Workstations VLAN.  A Windows workstation is deployed to the Enterprise Services VLAN.  A Cisco Firepower access control policy has been configured, with a default action of Block All Traffic, and applied to the Cisco FTD appliance.  The Cisco FTD appliance has been configured to provide DHCP services for the HIS Services and Clinical Workstations VLANs. Test connectivity between devices in the same subnet. 1. Power on the Windows workstation and log in. 2. Power on the Windows Server and log in. 3. On the Windows workstation, right-click the Windows Start Button.

NIST SP 1800-30B: Securing Telehealth Remote Patient Monitoring Ecosystem

66

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

4. Click Windows PowerShell (Admin). 5. Run the command ipconfig 6. Note the IP address (192.168.44.101). 7. On the Windows Server, right-click the Windows Start Button. 8. Click Windows PowerShell (Admin). 9. Run the command ipconfig 10. Ensure that the IP address (192.168.44.102) is in the same subnet as the Windows workstation. 11. On the Windows workstation, open an internet browser. 12. In the address bar, type in the address of the Windows Server, http://192.168.44.102. 13. Check if the default IIS landing page is displayed. Test connectivity between devices in separate subnets with no access control policy rules set. 14. Power off the Windows Server. 15. Move it to the HIS Services VLAN. 16. Power on the Windows Server and log in. 17. On the Windows workstation, right-click the Windows Start Button. 18. Click Windows PowerShell (Admin). 19. Run the command ipconfig 20. Note the IP address (192.168.41.100). 21. On the Windows workstation, open an internet browser. 22. In the address bar, type in the address of the Windows Server, http://192.168.41.100. 23. Check if the connection times out and the IIS web service cannot be reached. Test connectivity between devices in separate subnets with an access control policy rule set to allow. 24. Power on the Windows workstation in the Enterprise Services VLAN and log in. 25. Open an internet browser. 26. In the address bar, type in the address of the Cisco FMC, https://192.168.40.100. 27. Log in to the Cisco FMC with your admin credentials. 28. Navigate to Policies > Access Control > Access Control. 29. Select the default access control policy. 30. Click Add Rule. 31. Give the rule a name. 32. Set the rule’s action to Allow.

NIST SP 1800-30B: Securing Telehealth Remote Patient Monitoring Ecosystem

67

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

Expected Results Actual Results

6.1.7

33. Under Networks > Source Networks, type the IP address of the Windows workstation in the Clinical Workstations VLAN (192.168.44.101). 34. Click Add. 35. Under Networks > Destination Networks, type the IP address of the Windows Server in the HIS Services VLAN (192.168.41.100). 36. Click Add. 37. Under Ports > Available Ports, select HTTP and click Add to Destination. 38. Click Add to create the rule. 39. Click Save and Deploy the configuration to the Cisco FTD. 40. On the Windows workstation in the Clinical Workstations VLAN, open an internet browser. 41. In the address bar, type in the address of the Windows Server in the HIS Services VLAN, http://192.168.41.100. 42. Check if the default IIS landing page is displayed.  Devices in separate subnets are not able to communicate with each other until an access control policy rule has been created to allow that communication. When the workstation and server were both placed inside the Clinical Workstations VLAN, the workstation was able to access the server’s web service, successfully displaying the server’s default IIS web page. After the server was moved to the HIS Services VLAN, the workstation was no longer able to reach the server’s web service. Instead of displaying the default IIS web page, the workstation’s internet browser returned an error code and stated that the web service could not be reached. A new access control policy rule was created and applied to the Cisco FTD, allowing hypertext transfer protocol (HTTP) traffic from the workstation to the server. Once the rule was created, the workstation was able to access the server’s web service and display the default IIS web page.

Test Case: RPM-6

Cybersecurity Framework Category Testable Requirement(s) Description Preconditions

Security Continuous Monitoring (CR-8) malware protection Demonstrate the ability to protect the network and end points from malicious services by blocking the service before a connection is made.  Two Cisco Umbrella Forwarder appliances have been deployed to the Enterprise Services VLAN.

NIST SP 1800-30B: Securing Telehealth Remote Patient Monitoring Ecosystem

68

The domain’s DHCP service has been configured to provide the Cisco Umbrella Forwarder appliances as the primary and secondary DNS providers.  A Cisco Umbrella policy has been created, with no malware blocking, and has been applied to the Cisco Umbrella Forwarder appliances.  A Windows workstation is deployed to the Clinical Workstations VLAN. Test connectivity to outside malicious service with no Umbrella policy. 1. Power on the Windows workstation and log in. 2. Right-click the Windows Start Button. 3. Click Windows PowerShell (Admin). 4. Run the command ipconfig/all. 5. Under DNS Servers, ensure that the IP addresses listed correspond to the deployed Cisco Umbrella Forwarder appliances, 192.168.40.30 and 192.168.40.31. 6. Open an internet browser. 7. In the address bar, type in the address of Cisco’s malware test page, examplemalwaredomain.com. 8. Check if the site loads and no block message is displayed. 

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

Procedure

Test connectivity to outside malicious service with Umbrella policy. 9. Open an internet browser. 10. In the address bar, type in the address of the Cisco Umbrella dashboard, dashboard.umbrella.com. 11. Log in to the Cisco Umbrella dashboard with your admin credentials. 12. Navigate to Policies > Management > All Policies. 13. Open the policy applied to the Cisco Umbrella Forwarder appliances. 14. Under Security Setting Applied, click Edit. 15. Under Categories to Block, click Edit. 16. Click the checkbox next to Malware. 17. Click Save. 18. Click Proceed to confirm the changes. 19. Click Set & Return to save the default settings. 20. Click Save to update the policy applied to the Cisco Umbrella Forwarder appliances. 21. On the Windows workstation in the Clinical Workstations VLAN, open an internet browser.

NIST SP 1800-30B: Securing Telehealth Remote Patient Monitoring Ecosystem

69

Expected Results

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

Actual Results

6.1.7

22. In the address bar, type in the address of Cisco’s malware test page, examplemalwaredomain.com. 23. Check if the site does not load and a Cisco Umbrella block message is displayed.  When the Cisco Umbrella policy is active, devices within the HDO environment will not be able to access potentially malicious web services outside the HDO. To start, the Cisco Umbrella policy applied to the Forwarder appliances was not configured to block external sites that have been flagged for potential malware. Using a workstation in the Clinical Workstations VLAN, we navigated to a test malware site hosted by Cisco (examplemalwaredomain.com) to verify Cisco Umbrella’s effectiveness. Without the malware policy in place, the workstation was able to successfully reach the test malware site. After this, the Cisco Umbrella policy was configured to block external sites that have been flagged for potential malware. With the policy in place, the workstation was used again to connect to the test malware site, this time receiving a Cisco Umbrella block page notifying us that access to the site was not permitted.

Test Case: RPM-7

Cybersecurity Framework Category Testable Requirement(s) Description Preconditions

Procedure

Security Continuous Monitoring (CR-9) malicious activity detection Demonstrate the ability to detect anomalous network traffic and create an alert for further investigation.  Cisco Stealthwatch has been configured and licensed.  A Cisco Stealthwatch Flow Collector has been deployed to the Security Services VLAN and is being managed by the Cisco Stealthwatch Management Console (SMC).  The Cisco FTD has been configured to send NetFlow traffic to the Cisco Stealthwatch Flow Collector for analysis.  A Windows workstation is deployed to the Security Services VLAN.  An Ubuntu workstation, with the Nmap tool installed, has been deployed to the HIS Services VLAN. Configure Cisco Stealthwatch policy rule. 1. Power on the Ubuntu workstation and log in. 2. Run the command ifconfig 3. Note the IP address (192.168.41.10). 4. Power on the Windows workstation and log in.

NIST SP 1800-30B: Securing Telehealth Remote Patient Monitoring Ecosystem

70

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

5. Open an internet browser. 6. In the address bar, type in the address of the Cisco SMC, https://192.168.45.30. 7. Log in to the Cisco SMC with your admin credentials. 8. Navigate to Configure > Policy Management. 9. Click Create New Policy and select Single Host Policy. 10. Under IP Address, type the IP address of the Ubuntu workstation, 192.168.41.10. 11. Click Select Events. 12. Select Recon. 13. Click Apply. 14. Under When Host is Source, select On + Alarm. 15. Click Save.

Expected Results Actual Results

6.1.8

Test ability for Cisco Stealthwatch to detect a network discovery scan and create an alert. 16. On the Ubuntu workstation, run the command nmap 192.168.40.0/24 to perform a host scan of the Enterprise Services VLAN. 17. On the Windows workstation, bring up the Cisco Stealthwatch session and navigate to Dashboards > Network Security. 18. Check if the scan from the Ubuntu workstation has triggered one or more alarms.  The network scans from the Ubuntu workstation will trigger some form of alert from Cisco Stealthwatch. Once the Cisco Stealthwatch policy rule had been created, it took roughly a minute after the Nmap scan had run to begin displaying alerts on the Cisco Stealthwatch dashboard. The Ubuntu workstation from which the scans originated, 192.168.41.10, was listed on the dashboard under Top Alarming Hosts and was also listed in the Recon category under Today’s Alarms. On top of triggering the Recon rule that we had created, the scans also triggered a New Flows Initiated alarm for exceeding a threshold number of new flows within a set period.

Test Case: RPM-8

Cybersecurity Framework Category Testable Requirement(s) Description

Security Continuous Monitoring (CR-10) end-point monitoring and protection Demonstrate the ability to detect unusual authentication behaviors and file integrity changes on protected end points.

NIST SP 1800-30B: Securing Telehealth Remote Patient Monitoring Ecosystem

71

Preconditions

Procedure

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

LogRhythmXDR has been configured and licensed. A Windows Server is deployed to the Clinical Workstations VLAN. The Windows Server has a LogRhythm System Monitor Agent installed. Enable user activity monitor services on the Clinical Workstation. 1. Power on the LogRhythmXDR host and log in. 2. Start the Management Console application. 3. Click Deployment Manager. 4. Click System Monitors. 5. Double-click the Windows Server. 6. Click Endpoint Monitoring. 7. Click User Activity Monitor. 8. Click the checkbox next to Monitor Logon Activity. 9. Click the checkbox next to Monitor Network Session Activity. 10. Click the checkbox next to Monitor Process Activity. 11. Click OK.   

Create a file integrity monitor policy for the Clinical Workstation. 12. Power on the Windows Server and log in with an administrator account. 13. Open the File Explorer application. 14. Navigate to This PC > Local Disc (C:). 15. Create a new folder and name it testdirectory. 16. Create a new text document inside the testdirectory folder and name it testfile. 17. On the LogRhythmXDR workstation, open the Management Console application. 18. Click Deployment Manager. 19. Under Tools, select Administration. 20. Click File Integrity Monitor Policy Manager. 21. In the dialog box, right-click and select New. 22. Name the policy NCCoE Testdirectory. 23. Provide a Description. 24. Under Monitoring Configuration, right-click and select New. 25. Name the policy testdirectory configuration. 26. Under Monitoring Flags, select Modify and Permission. 27. Under Monitored Items, right-click and select New. 28. Under Type, select Directory. 29. Under Path, type C:\testdirectory. 30. Click Apply. 31. Click OK. 32. Click System Monitors.

NIST SP 1800-30B: Securing Telehealth Remote Patient Monitoring Ecosystem

72

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

33. Double-click the Windows Server. 34. Click Endpoint Monitoring. 35. Click File Integrity Monitor. 36. Click the checkbox next to Enable File Integrity Monitor. 37. Select Realtime mode. 38. Click the checkbox next to Enable Realtime Mode Anomaly Detection. 39. Under Policy, select NCCoE Testdirectory. 40. Click Apply. 41. Click OK. Create an artificial intelligence (AI) engine rule. 42. Click Deployment Manager. 43. Click AI Engine. 44. Click Create a New Rule. 45. Under Rule Block Types, select and drag a rule block to the Rule Block Designer. 46. Under each tab, fill out the necessary information. 47. Click Next. 48. Click OK. 49. Create a rule for Authentication Failure Monitoring. a. AI Engine Rule Name: NCCoE Authentication failure threshold b. Data Source: Data Processor Logs c. Primary Criteria -> Classification: Authentication Failure d. Log Sources: All Log Sources e. Group By: Host (Impacted), User (Origin) 50. Create a rule for File Integrity Monitoring. a. AI Engine Rule Name: NCCoE Use Case File Activity b. Data Source: Data Processor Logs c. Primary Criteria -> Common Event: File Monitoring Event–Add, File Monitoring Event–Modify d. Log Sources: All Log Sources e. Group By: User (Origin), Object 51. For both new rules, click the checkbox for Action. 52. Under Actions, select Enable. Test user activity monitoring. 53. Power on the Windows Server. 54. Attempt to log in with a username and invalid password at least five times.

NIST SP 1800-30B: Securing Telehealth Remote Patient Monitoring Ecosystem

73

View user authentication failure alerts. 55. On the LogRhythmXDR host, open an internet browser. 56. In the address bar, type in the address of the LogRhythm Web Console, https://logrhythm-host:8443, and log in. 57. Click the Alarms tab. 58. Check for alerts coinciding with the user authentication failures. This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

Test file integrity monitoring. 59. On the Windows Server, log in with an administrator account. 60. Open the File Explorer application. 61. Navigate to This PC > Local Disc (C:) > testdirectory. 62. Open the testfile text document. 63. Modify the content of the testfile text document. 64. Under File, select Save.

Expected Results

Actual Results

View file integrity monitoring alerts. 65. On the LogRhythmXDR workstation, open an internet browser. 66. In the address bar, type in the address of the LogRhythm Web Console, https://logrhythm-host:8443, and log in. 67. Click the Alarms tab. 68. Check for alerts coinciding with the file modification.  The unusual authentication behavior will trigger an alarm event that is viewable in the LogRhythm Web Console.  The unauthorized file modification will trigger an alarm event that is viewable in the LogRhythm Web Console, and log files will identify the user who has performed the file modification. Once LogRhythmXDR was configured to provide user activity monitoring and file integrity monitoring, we began by testing the user activity monitoring. For this test, we powered on the Windows Server in the Clinical Workstations VLAN that had been configured with a LogRhythm System Monitor Agent. We made five consecutive login attempts using an invalid password, which was then detected by LogRhythm, and an alert was created that was visible on the LogRhythm Web Console. Next, we tested the file integrity monitoring. For this test, we logged in to the Windows Server in the Clinical Workstations VLAN and made some modifications to the testfile text document in the C:\testdirectory folder. Once the changes had been saved, an alarm was triggered and visible in the LogRhythm Web Console. From the alert, we could also drill down to the event and determine what user had made the modification.

NIST SP 1800-30B: Securing Telehealth Remote Patient Monitoring Ecosystem

74

6.1.9

Test Case: RPM-9

Cybersecurity Framework Category Testable Requirement(s) Associated Test Case(s) Description This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

Preconditions

Procedure

Security Continuous Monitoring (CR-11) end-point network access monitoring  RPM-8 This test case demonstrates the ability to create alarms for unauthorized network traffic.  LogRhythm NetworkXDR has been configured and licensed.  A Windows Server is deployed to the Clinical Workstations VLAN.  The Windows Server has a LogRhythm System Monitor Agent installed. Enable user network connection monitor on the Clinical Workstation. 1. Power on the LogRhythmXDR host and log in. 2. Start the Management Console application. 3. Click Deployment Manager. 4. Click System Monitors. 5. Double-click the Windows Server. 6. Click Endpoint Monitoring. 7. Click User Activity Monitor. 8. Click the checkbox next to Monitor Logon Activity. 9. Click the checkbox next to Monitor Network Session Activity. 10. Click the checkbox next to Monitor Process Activity. 11. Click OK. 12. Click Network Connection Monitor. 13. Click the checkbox next to Enable Network Connection Monitor. 14. Click the checkbox next to Monitor Inbound TCP Connections. 15. Click the checkbox next to Monitor Outbound TCP Connections. 16. Click the checkbox next to Monitor Listening TCP/UDP Sockets. 17. Click the checkbox next to Include User Activity Monitor Data (Required UAM). 18. Click OK. Create an AI engine rule. 19. Click Deployment Manager. 20. Click AI Engine. 21. Click Create a New Rule. 22. Under Rule Block Types, select and drag a rule block to the Rule Block Designer. 23. Under each tab, fill out the necessary information. 24. Click Next. 25. Click OK.

NIST SP 1800-30B: Securing Telehealth Remote Patient Monitoring Ecosystem

75

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

26. Create a rule for Monitoring HTTP Traffic. a. AI Engine Rule Name: NCCoE HTTP traffic from clinical workstation b. Data Source: Data Processor Logs c. Primary Criteria -> Application: HTTP, Know Host (origin)–Windows Server d. Log Sources: All Log Sources e. Group By: Host (Origin), Application 27. For the new rule, click the checkbox for Action. 28. Under Actions, select Enable. Test user network connectivity monitoring. 29. Power on the Windows Server and log in. 30. Open an internet browser. 31. In the address bar, type the address of a web service by using the http protocol, as in http://www.msn.com/.

Expected Results Actual Results

View user network connectivity monitoring alerts. 32. On the LogRhythmXDR host, open an internet browser. 33. In the address bar, type in the address of the LogRhythm Web Console, https://logrhythm-host:8443, and log in. 34. Click the Alarms tab. 35. Check for alerts coinciding with use of the http protocol.  Connecting to a web service using the http protocol will trigger an alarm event that is viewable in the LogRhythm Web Console. Once LogRhythmXDR and NetworkXDR were configured to provide user network connection monitoring, we powered on the Windows Server in the Clinical Workstations VLAN that had been configured with a LogRhythm System Monitor Agent. After logging in, we opened a web browser and connected to http://www.msn.com/. LogRhythm detected use of the http protocol and created an alert that was visible on the LogRhythm Web Console.

6.1.10 Test Case: RPM-10 Cybersecurity Framework Category Testable Requirement(s) Description

Data Security (CR-12) data-in-transit is protected Demonstrate the ability to protect data-in-transit between the patient home and the telehealth platform.

NIST SP 1800-30B: Securing Telehealth Remote Patient Monitoring Ecosystem

76

Preconditions

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

Procedure

An Onclave environment has been deployed, including the Onclave Telehealth Gateway and Wireless Onclave Home Gateway.  A Vivify Pathways Care Team Portal is deployed behind the Onclave Telehealth Gateway, on the Telehealth Onclave VLAN.  Wireshark has been installed and configured on the Vivify Pathways Care Team Portal.  A mobile device has been provided by Vivify and configured to communicate with the Vivify Pathways Care Team Portal.  The mobile device is deployed behind the Wireless Onclave Home Gateway. Verify that the Vivify Pathways Care Team Portal is operational. 1. Power on the Vivify Pathways Care Team Portal. 2. Open an internet browser. 3. In the address bar, type https://localhost. 4. Ensure that the Vivify Pathways Care Team Portal landing page is displayed. 

Test connectivity between the mobile device and Vivify Portal when connected to the Onclave Wireless Home Gateway. 5. On the Vivify Portal system, click on the Windows Start Button. 6. Type Wireshark and open the Wireshark application. 7. Start a packet capture on the Ethernet0 network interface. 8. Using the mobile device, begin a new patient reading. 9. Follow the instructions until the patient reading is complete. 10. On the Vivify Portal system, stop the Wireshark packet capture. 11. Check if there are packets received from the mobile device’s IP address, 192.168.50.104. 12. Check if the packets are obfuscated. 13. Open an internet browser. 14. In the address bar, type https://localhost. 15. Log in to the telehealth platform with your admin credentials. 16. Click on the patient for whom the readings were taken. 17. Check if the patient’s readings were successfully transmitted from the mobile device to the Vivify Portal. Test connectivity between the mobile device and Vivify Portal when not connected to the Wireless Onclave Home Gateway. 18. On the mobile device, change the device’s Wi-Fi to VLAN 1332. 19. On the Vivify Portal system, start a new packet capture on the network interface using Wireshark. 20. Using the mobile device, begin a new patient reading.

NIST SP 1800-30B: Securing Telehealth Remote Patient Monitoring Ecosystem

77

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

Expected Results

Actual Results

21. Follow the instructions until the patient reading is complete. 22. On the Vivify Portal, stop the Wireshark packet capture. 23. Check that there are no packets received from the mobile device’s IP address, 192.168.50.104. 24. Open an internet browser. 25. In the address bar, type https://localhost. 26. Log in to the telehealth platform with your admin credentials. 27. Click on the patient for whom the readings were taken. 28. Check if the patient’s readings were not successfully transmitted from the mobile device to the Vivify Portal.  The mobile device can communicate with the Vivify Portal only when the mobile device is connected to the Wireless Onclave Home Gateway.  Data transmitted from and to the mobile device are encrypted. The mobile device successfully transmitted data to the Vivify Portal when connected to the Wireless Onclave Home Gateway. The Wireshark packet analysis tool was used to capture network traffic. Captured traffic was observed to be encrypted. When the mobile device was not connected to the Wireless Onclave Home Gateway, data were not transmitted to the Vivify Portal.

6.1.11 Test Case: RPM-11 Cybersecurity Framework Category Testable Requirement(s) Description Preconditions

Procedure

N/A (CR-13) business workflow Demonstrate that the telehealth platform provider can receive a patient’s biomedical data from the patient home and present this data to the HDO.  Implement an RPM architecture and verify that network connections among the Patient Home, Telehealth Platform Provider, and HDO are functioning.  Place RPM peripherals in the Patient Home environment.  Connect the provided RPM interface to the Patient Home network.  Create accounts for the HDO’s clinicians on the Telehealth Platform Provider’s platform.  Ensure clinicians are associated with their patients on the thirdparty platform. Accuhealth–gather biomedical readings from devices with a cellular connection.

NIST SP 1800-30B: Securing Telehealth Remote Patient Monitoring Ecosystem

78

1. Interface with the weight scale provided by Accuhealth and record the measurement. 2. Interface with the blood glucose monitor provided by Accuhealth and record the measurement. 3. Interface with the blood pressure monitor provided by Accuhealth and record the measurement. This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

Accuhealth–view and verify that patient data were stored in the telehealth platform from the HDO network. 4. Log in to Accuhealth’s platform by using the credentials that it provided from a workstation connected to the HDO network. 5. Navigate to the patient account associated with the provided peripheral devices. 6. Verify that the biomedical readings taken in steps 1-3 are listed. Vivify—gather biomedical readings from devices with a broadband connection. 1. Interface with the RPM tablet provided by Vivify and answer the presented survey questions. 2. Interface with the blood pressure monitor provided by Vivify and verify that the tablet has the correct reading. 3. Interface with the oximeter provided by Vivify and verify that the tablet has the correct reading. 4. Interface with the weight scale provided by Vivify and verify that the tablet has the correct reading. 5. Interface with the blood glucose monitoring system provided by Vivify and verify that the tablet has the correct reading.

Expected Results

Vivify–view and verify that patient data were stored in the telehealth platform from the HDO network. 6. Log in to Vivify’s platform by using the credentials that it provided from a workstation connected to the HDO network. 7. Navigate to the patient account associated with the provided peripheral devices. 8. Verify that the biomedical readings and survey answers provided in steps 1-5 are listed.  The biomedical readings gathered from the provided RPM devices should be transmitted to a patient account on the appropriate telehealth platform provider platforms.  Clinicians should be able to access these readings from the HDO network by logging in to the platforms and using the credentials provided to them by the third-party platform.

NIST SP 1800-30B: Securing Telehealth Remote Patient Monitoring Ecosystem

79

Actual Results

Biomedical readings were transmitted from the patient’s home to the telehealth platform provider. Clinicians were also able to access and view the patient’s biomedical readings from the HDO network by logging in to the third party’s platform and using their provided credentials.

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30. NIST SP 1800-30B: Securing Telehealth Remote Patient Monitoring Ecosystem

80

7 Future Build Considerations

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

This practice guide implemented biometric devices that used cellular data communications. This guide also addressed biometric devices using broadband communications. The practice guide implemented Onclave Networks as a proof-of-concept solution that provides layer 2 over layer 3 protection in a zero trust architecture model. This practice guide simulated a telehealth platform provider and deployed the Onclave solution to demonstrate how data communications between the patient home and telehealth platform provider may be secured. The solution assures that biometric devices are segmented from other devices that may appear in a patient home network. A future build may also implement an EHR system that would receive automated data from the telehealth platform provider. Patient-initiated messages from RPM components deployed to the patient home were contained within the RPM systems hosted within an application to which HDOs connected for review and analysis. The future build may include direct messaging from the RPM systems to the EHR.

NIST SP 1800-30B: Securing Telehealth Remote Patient Monitoring Ecosystem

81

Appendix A

List of Acronyms

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

AD

Active Directory

AES

Advanced Encryption Standard

AI

Artificial Intelligence

AMP

Advanced Malware Protection

CIA

Confidentiality, Integrity, and Availability

COI

Community of Interest

CTI

Cyber Threat Intelligence

DC

Domain Controller

DHCP

Dynamic Host Configuration Protocol

DNS

Domain Name System

EHR

Electronic Health Record

FTD

Firepower Threat Defense

HDO

Healthcare Delivery Organization

HIPAA

Health Insurance Portability and Accountability Act

HIS

Health Information System

HTTP

Hypertext Transfer Protocol

IEC

International Electrotechnical Commission

IIS

Internet Information Services

IP

Internet Protocol

ISO

International Organization for Standardization

IT

Information Technology

IoT

Internet of Things

LAN

Local Area Network

LTE

Long-Term Evolution

MAC

Media Access Control

NIST SP 1800-30B: Securing Telehealth Remote Patient Monitoring Ecosystem

82

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

NCCoE

National Cybersecurity Center of Excellence

NFC

Near Field Communication

NICE

National Initiative for Cybersecurity Education

NIST

National Institute of Standards and Technology

OS

Operating System

OSI

Open Systems Interconnection

PACS

Picture Archiving and Communication System

PAN

Personal Area Network

PRAM

Privacy Risk Assessment Methodology

RMF

Risk Management Framework

RPM

Remote Patient Monitoring

SaaS

Software as a Service

SC

Security Categorization

SD

Secure Digital

SIEM

Security Incident and Event Management

SIM

Subscriber Identity Module

SMC

Stealthwatch Management Console

SP

Special Publication

TLS

Transport Layer Security

URL

Uniform Resource Locator

USB

Universal Serial Bus

VLAN

Virtual Local Area Network

ZTA

Zero Trust Architecture

NIST SP 1800-30B: Securing Telehealth Remote Patient Monitoring Ecosystem

83

Appendix B

References

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

[1]

R. Ross et al., Protecting Controlled Unclassified Information in Nonfederal Systems and Organizations, National Institute of Standards and Technology (NIST) Special Publication (SP) 800-171 Revision 2, NIST, Gaithersburg, Md., Feb. 2020. Available: https://nvlpubs.nist.gov/nistpubs/SpecialPublications/NIST.SP.800-171r2.pdf.

[2]

R. Petersen et al., Workforce Framework for Cybersecurity (NICE Framework), NIST SP 800-181 Revision 1, NIST, Gaithersburg, Md., Nov. 2020. Available: https://nvlpubs.nist.gov/nistpubs/SpecialPublications/NIST.SP.800-181r1.pdf.

[3]

Framework for Improving Critical Infrastructure Cybersecurity, Version 1.1 (NIST Cybersecurity Framework), NIST, Gaithersburg, Md., Apr. 16, 2018. Available: https://nvlpubs.nist.gov/nistpubs/CSWP/NIST.CSWP.04162018.pdf.

[4]

NIST. Risk Management Framework: Quick Start Guides. Available: https://csrc.nist.gov/projects/risk-management/risk-management-framework-quick-startguides.

[5]

NIST. NIST Privacy Framework: A Tool for Improving Privacy Through Enterprise Risk Management, Version 1.0 (Privacy Framework). Jan. 16, 2020. Available: https://nvlpubs.nist.gov/nistpubs/CSWP/NIST.CSWP.01162020.pdf.

[6]

NIST. Computer Security Resource Center. Available: https://csrc.nist.gov/glossary/term/confidentiality_integrity_availability.

[7]

NIST. NIST Privacy Risk Assessment Methodology (PRAM). Jan. 16, 2020. Available: https://www.nist.gov/privacy-framework/nist-pram.

[8]

NIST. Privacy Engineering Program: Privacy Risk Assessment Methodology (PRAM), Catalog of Problematic Data Actions and Problems. Available: https://www.nist.gov/itl/appliedcybersecurity/privacy-engineering/resources.

[9]

Joint Task Force Transformation Initiative, Guide for Conducting Risk Assessments, NIST SP 80030 Revision 1, NIST, Gaithersburg, Md., Sept. 2012. Available: https://nvlpubs.nist.gov/nistpubs/Legacy/SP/nistspecialpublication800-30r1.pdf.

[10] Joint Task Force, Security and Privacy Controls for Federal Information Systems and Organizations, NIST SP 800-53 Revision 5, NIST, Gaithersburg, Md., Sept. 2020. Available: https://nvlpubs.nist.gov/nistpubs/SpecialPublications/NIST.SP.800-53r5.pdf.

NIST SP 1800-30B: Securing Telehealth Remote Patient Monitoring Ecosystem

84

[11] Application of risk management for IT networks incorporating medical devices–Part 2-2: Guidance for the disclosure and communication of medical device security needs, risks and controls, International Organization for Standardization (ISO)/International Electrotechnical Commission (IEC) Technical Report (TR) 80001-2-2, Edition 1.0 2012-07, International Electrotechnical Commission.

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

[12] U.S. Department of Health and Human Services Office for Civil Rights, HIPAA Security Rule Crosswalk to NIST Cybersecurity Framework, Feb. 2016. Available: https://www.hhs.gov/sites/default/files/nist-csf-to-hipaa-security-rule-crosswalk-02-22-2016final.pdf. [13] ISO/IEC, Information technology–Security techniques–Information security management systems–Requirements, ISO/IEC 27001:2013, 2013. [14] J. Cawthra et al., Securing Picture Archiving and Communication System (PACS) Project Description, NIST, Gaithersburg, Md., Jan. 2018. Available: https://www.nccoe.nist.gov/sites/default/files/library/project-descriptions/hit-pacs-projectdescription-final.pdf. [15] NIST. NIST Privacy Framework, NIST Privacy Framework and Cybersecurity Framework to NIST Special Publication 800-53, Revision 5 Crosswalk, Dec. 2020. Available: https://www.nist.gov/privacy-framework/nist-privacy-framework-and-cybersecurityframework-nist-special-publication-800-53. [16] World Health Organization. Health Topics. Diabetes. Available: https://www.who.int/healthtopics/diabetes#tab=tab_1. [17] P. Lee et al., The impact of telehealth remote patient monitoring on glycemic control in type 2 diabetes: a systematic review and meta-analysis of systematic reviews of randomised controlled trials, U.S. National Library of Medicine, National Institutes of Health. Available: https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6019730/. [18] U.S. National Library of Medicine. Cardiac Rehabilitation. Available: https://medlineplus.gov/cardiacrehabilitation.html#summary. [19] U.S. National Library of Medicine. Pulmonary Rehabilitation. Available: https://medlineplus.gov/pulmonaryrehabilitation.html. [20] G. O’Brien et al., Securing Wireless Infusion Pumps in Healthcare Delivery Organizations, NIST SP 1800-8, NIST, Gaithersburg, Md., Aug. 2018. Available: https://www.nccoe.nist.gov/sites/default/files/library/sp1800/hit-wip-nist-sp1800-8.pdf.

NIST SP 1800-30B: Securing Telehealth Remote Patient Monitoring Ecosystem

85

[21] M. Fagan et al., IoT Device Cybersecurity Guidance for the Federal Government: Establishing IoT Device Cybersecurity Requirements, NIST SP 800-213, NIST, Gaithersburg, Md., Nov. 2021. Available: https://nvlpubs.nist.gov/nistpubs/SpecialPublications/NIST.SP.800-213.pdf. [22] S. Rose et al., Zero Trust Architecture, NIST SP 800-207, NIST, Gaithersburg, Md., Aug. 2020. Available: https://nvlpubs.nist.gov/nistpubs/SpecialPublications/NIST.SP.800-207.pdf. This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

[23] C. Johnson et al., Guide to Cyber Threat Information Sharing, NIST SP 800-150, NIST, Gaithersburg, Md., Oct. 2016. Available: https://nvlpubs.nist.gov/nistpubs/SpecialPublications/NIST.SP.800-150.pdf. [24] K. Dempsey et al., Information Security Continuous Monitoring (ISCM) for Federal Information Systems and Organizations, Information Security, NIST SP 800-137, NIST, Gaithersburg, Md., Sept. 2011. Available: https://nvlpubs.nist.gov/nistpubs/Legacy/SP/nistspecialpublication800137.pdf. [25] J. Cichonski et al., Guide to LTE Security, NIST SP 800-187, NIST, Gaithersburg, Md., Dec. 2017. Available: https://nvlpubs.nist.gov/nistpubs/SpecialPublications/NIST.SP.800-187.pdf. [26] K. McKay and D. Cooper, Guidelines for the Selection, Configuration, and Use of Transport Layer Security (TLS) Implementations, NIST SP 800-52 Revision 2, NIST, Gaithersburg, Md., Aug. 2019. Available: https://nvlpubs.nist.gov/nistpubs/SpecialPublications/NIST.SP.800-52r2.pdf. [27] E. Barker, Recommendation for Key Management: Part 1–General, NIST SP 800-57 Part 1 Revision 5, NIST, Gaithersburg, Md., May 2020. Available: https://nvlpubs.nist.gov/nistpubs/SpecialPublications/NIST.SP.800-57pt1r5.pdf. [28] U.S. Department of Commerce, Advanced Encryption Standard (AES), NIST Federal Information Processing Standards (FIPS) Publication 197, Nov. 26, 2001. Available: https://csrc.nist.gov/csrc/media/publications/fips/197/final/documents/fips-197.pdf. [29] U.S. Department of Commerce, Standards for Security Categorization of Federal Information and Information Systems, NIST Federal Information Processing Standards Publication 199, Feb. 2004. Available: https://nvlpubs.nist.gov/nistpubs/FIPS/NIST.FIPS.199.pdf. [30] K. Stine et al., Guide for Mapping Types of Information and Information Systems to Security Categories Volume I, NIST SP 800-60 Volume I Revision 1, NIST, Gaithersburg, Md., Aug. 2008. Available: https://nvlpubs.nist.gov/nistpubs/Legacy/SP/nistspecialpublication800-60v1r1.pdf. [31] K. Stine et al., Appendices to Guide for Mapping Types of Information and Information Systems to Security Categories Volume II, NIST SP 800-60 Volume II Revision 1, NIST, Gaithersburg, Md., Aug. 2008. Available: https://nvlpubs.nist.gov/nistpubs/Legacy/SP/nistspecialpublication80060v2r1.pdf.

NIST SP 1800-30B: Securing Telehealth Remote Patient Monitoring Ecosystem

86

[32] U.S. Department of Commerce, Minimum Security Requirements for Federal Information and Information Systems, NIST Federal Information Processing Standards Publication 200, Mar. 2006. Available: https://nvlpubs.nist.gov/nistpubs/FIPS/NIST.FIPS.200.pdf. [33] S. Quinn et al., National Checklist Program for IT Products–Guidelines for Checklist Users and Developers, NIST SP 800-70 Revision 4, NIST, Gaithersburg, Md., Feb. 2018. Available: https://nvlpubs.nist.gov/nistpubs/SpecialPublications/NIST.SP.800-70r4.pdf. This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

[34] Joint Task Force Transformation Initiative, Assessing Security and Privacy Controls in Federal Information Systems and Organizations: Building Effective Assessment Plans, NIST SP 800-53A Revision 4, NIST, Gaithersburg, Md., Dec. 2014. Available: https://nvlpubs.nist.gov/nistpubs/SpecialPublications/NIST.SP.800-53Ar4.pdf. [35] Joint Task Force, Risk Management Framework for Information Systems and Organizations: A System Life Cycle Approach for Security and Privacy, NIST SP 800-37 Revision 2, NIST, Gaithersburg, Md., Dec. 2018. Available: https://nvlpubs.nist.gov/nistpubs/SpecialPublications/NIST.SP.800-37r2.pdf. [36] S. Brooks et al., An Introduction to Privacy Engineering and Risk Management in Federal Systems, NIST Internal Report 8062, NIST, Gaithersburg, Md., Jan. 2017. Available: https://nvlpubs.nist.gov/nistpubs/ir/2017/NIST.IR.8062.pdf. [37] J. Padgette et al., Guide to Bluetooth Security, NIST SP 800-121 Revision 2, NIST, Gaithersburg, Md., May 2017. Available: https://nvlpubs.nist.gov/nistpubs/SpecialPublications/NIST.SP.800121r2.pdf. [38] NIST Cybersecurity for IoT Program, Feb. 2021. Available: https://www.nist.gov/programsprojects/nist-cybersecurity-iot-program. [39] International Organization for Standardization/International Electrotechnical Commission, Information technology–Open Systems Interconnection–Basic Reference Model: The Basic Model, ISO/IEC 7498-1, 1994.

NIST SP 1800-30B: Securing Telehealth Remote Patient Monitoring Ecosystem

87

Appendix C

Threats and Risks

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

Organizations need to understand risks associated with systems they deploy. The National Institute of Standards and Technology (NIST) provides two bodies of work that enable organizations to examine risk and determine how risks may be mitigated. The National Cybersecurity Center of Excellence (NCCoE) uses the NIST Cybersecurity Framework as guidance for managing risks in healthcare technology. Dovetailing with the Cybersecurity Framework is the NIST Risk Management Framework (RMF). This appendix discusses how the Cybersecurity Framework and the RMF may be applied when managing risks for the remote patient monitoring (RPM) environment.

C-1 Discussion on the Risk Management Framework This practice guide implements concepts in the NIST RMF [4]. The NIST RMF consists of a series of documents that may be applied in categorizing systems, selecting controls, assessing controls, and monitoring the security state of the overall architecture. The RMF captures this concept by describing a six-step process. The RMF security life cycle can be described as follows: Step

Description

Guidance Document(s)

1

categorize

Federal Information Processing Standards (FIPS) 199 [29]; NIST Special Publication (SP) 800-60 [30], [31]

2

select

FIPS 200 [32]; NIST SP 800-53 [10]

3

implement

NIST SP 800-70 [33]

4

assess

NIST SP 800-53A [34]

5

authorize

NIST SP 800-37 [35]

6

monitor

NIST SP 800-37 [35]; NIST SP 800-53A [34]

NIST SP 1800-30B: Securing Telehealth Remote Patient Monitoring Ecosystem

88

Figure C-1 Risk Management Framework [35]

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

Note that this practice guide does not apply the RMF sequentially as described. The NIST RMF, in this stepped approach, applies to new systems as they are evaluated for their suitability to transition from development to production environments. For this RPM practice guide, components are already developed. The approach that the project team uses in applying the RMF is first categorizing the system, then assessing risk and understanding threats that may result in risk. The team then selects controls to disrupt threats.

C-2 Information and Information System Categorization An initial step in performing a system risk assessment and then selecting and applying appropriate controls is to perform an information and information system categorization exercise. A method to categorize is described in NIST SP 800-60 Volumes I and II [30] [31], as well as in FIPS 199 [29]. These documents are a foundational step in the NIST Risk Management Framework. The NIST SP 800-60 volumes provide guidance on identifying information categories and provide recommended categorization, based on confidentiality (C), integrity (I), and availability (A) security objectives. In reviewing information types described in NIST SP 800-60 Volume II [31], the engineers selected two information types as relevant for the representative build: C.2.8.9, personal identity and authentication; and D.14.1, access to care. The two information types were recorded in Table C-1, Information Types and Categorizations, and provisional impact levels were captured, with the category levels corresponding to the recommended value found in NIST SP 800-60 Volume II [31].

NIST SP 1800-30B: Securing Telehealth Remote Patient Monitoring Ecosystem

89

Table C-1 Information Types and Categorizations

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

Information Type

NIST SP 800-60 Volume II Reference (e.g., C.2.8.9)

Confidentiality

Integrity

Availability

Justification (to change an impact level)

personal identity and authentication

C.2.8.9

moderate

moderate

moderate

N/A

access to care

D.14.1

low

moderate

low

N/A

moderate

moderate

moderate

N/A

Overall Rating

After identifying the information categories, one may determine the security objectives. Security objectives use a scale of low, medium, and high. FIPS 199 provides guidance in applying security categorization (SC). This practice guide identifies two information types: personal identity and authentication, as well as access to care. RPMʼs SC may be expressed as {(confidentiality, MODERATE), (integrity, MODERATE), (availability, MODERATE)} [29]. The SC provides a base guide for security controls selection.

C-3 Risk Context This practice guide describes risk from a systemic perspective while contextualizing risk. The RPM system for this practice guide consists of three domains. For this document, a domain is a group of assets whose maintenance and underlying infrastructure are the responsibility of discrete entities. In RPM, this practice guide implements a reference architecture that uses the patient home, the telehealth platform provider, and the healthcare delivery organization (HDO) as domains. Because each domain is managed and used by different entities, risks and threats may manifest differently in each domain. While HDOs and telehealth platform providers are corporate entities that are subject to regulatory obligations, the patient home tends to be managed by individuals. For RPM, HDOs and telehealth platform providers should provide guidance to patients in safeguarding their systems and information. Controls may be implemented on provisioned devices managed by HDOs or telehealth platform providers; however, other controls may need to be addressed through education and awareness. Despite how controls may be implemented, this practice guide examines the contextualized risks and threats and describes how the NCCoE implemented mitigating controls. Organizations that implement RPM practices should ensure that they apply due diligence by examining their own risk scenarios, including legal and regulatory obligations that may apply to their locale. Risks and threats should be

NIST SP 1800-30B: Securing Telehealth Remote Patient Monitoring Ecosystem

90

analyzed based on their context. This practice guide applies contextualized controls to disrupt threats as its strategy to mitigate risk.

C-4 Threats

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

In this practice guide, the NCCoE identified a threat taxonomy for the entire system. Threats may manifest differently to the system depending on the domain in which they appear. Environments that may have resources to maintain security tools and procedures may have mitigating circumstances that reduce the likelihood of attack and minimize impact based on pervasive controls. This practice guide considers scenarios where patient homes may have less resource and capability to minimize threats when compared with telehealth platform providers and HDOs. Also, for the purposes of this practice guide, some threats may target HDOs to a greater extent than patient homes or telehealth platform providers, given a more target-rich data set that may attract threat actors. The following tables describe events and consider the likelihood of variation based on this context. Note that the assigned values are notional. Practitioners who perform similar exercises may determine different assignments. For purposes of this exercise, likelihood is categorized using a range that extends from very low to very high, consistent with a model described in Appendix G of NIST 800-30 [9]. An abstract of the table appears below. The qualitative values from the Table C-2 describes threat likelihood.

NIST SP 1800-30B: Securing Telehealth Remote Patient Monitoring Ecosystem

91

Table C-2 Assessment Scale: Likelihood of Threat Event Initiation Qualitative Values

Frequency (derived from nonadversarial table) Error, accident, or act of nature is almost certain to occur or occurs more than 100 times per year.

Description (derived from adversarial table) Adversary is almost certain to initiate the threat event.

high

Error, accident, or act of nature is highly likely to occur or occurs 10-100 times per year.

Adversary is highly likely to initiate the threat event.

moderate

Error, accident, or act of nature is somewhat likely to occur or occurs 1-10 times per year.

Adversary is somewhat likely to initiate the threat event.

low

Error, accident, or act of nature is unlikely to occur or occurs less than once a year but more than every ten years.

Adversary is unlikely to initiate the threat event.

very low

Error, accident, or act of nature is highly unlikely to occur or occurs less than once every ten years.

Adversary is highly unlikely to initiate the threat event.

very high

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

The patient home may include technology and network infrastructure that offer malicious actors the opportunity to introduce disruption. Patients and individuals in the patient home come from different walks of life and may have varying degrees of experience in ensuring that privacy and cybersecurity are appropriately implemented for the devices that they may use. Malicious actors may opportunistically leverage a lack of robust controls in the patient home. While the patient home environment may have limited data to exfiltrate and data that pertain to a few individuals, the ability to compromise a patient home environment may pose fewer challenges than better resourced companies and hospital systems. Table C-3 Threats Applied to the Patient Home C, I, A

Threat Event

Description

Likelihood

C

phishing

Patients and individuals in the patient home may be susceptible to phishing attempts.

high

NIST SP 1800-30B: Securing Telehealth Remote Patient Monitoring Ecosystem

92

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

C, I, A

Threat Event

Description

Likelihood

I, A

malicious software

Patients and individuals in the patient home may be susceptible to permitting or introducing malicious software into the patient home environment.

moderate

I, A

command and control

Patients and individuals in the patient home may be susceptible to enabling malware that gives threat actors the ability to exercise command and control on devices.

moderate

A

ransomware

Ransomware may be introduced into the patient home environment either as links or attachments found in phishing emails or may be introduced through local media.

moderate

C

credential escalation

Malware may be introduced to the patient home environment that allows threat actors to execute arbitrary code and perform privileged functions.

low

I, A

operating system (OS) or application disruption

Malware may be introduced into the patient home environment that disrupts the operating system or applications. Libraries or subsystems may be affected.

moderate

C

data exfiltration

Sensitive data may be exposed to unauthorized individuals, e.g., via social engineering disclosure or malware that allows threat actors to retrieve data arbitrarily. Malware may be used for this purpose.

moderate

Using the same threat matrix, an examination is made of the telehealth platform provider. In general, the threat table considers when threat actors target workforce members who may have privileged access. The assumption is that telehealth platform providers may implement pervasive controls and have privacy and cybersecurity resources deployed that mitigate likelihood. The caveat in these assumptions is that HDOs that engage with telehealth platform providers should be provided assurance that third parties that they engage deploy mature privacy and cybersecurity programs.

NIST SP 1800-30B: Securing Telehealth Remote Patient Monitoring Ecosystem

93

Table C-4 Threats Applied to the Telehealth Platform Provider

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

C, I, A

Threat Event

Description

Likelihood

C

phishing

Telehealth platform provider workforce with privileged access may be susceptible to spear phishing attacks.

high

I, A

malicious software

Telehealth platform provider workforce with privileged access to permitting allows malicious software to be introduced into the telehealth platform environment.

moderate

I, A

command and control

Telehealth platform provider workforce with privileged access to permitting allows threat actors to execute arbitrary code and perform privileged functions.

low

A

ransomware

Ransomware may be introduced into the telehealth platform provider environment either as links or attachments found in phishing emails or may be introduced through local media.

moderate

C

credential escalation

Malware may be introduced to the telehealth platform provider environment that allows threat actors to execute arbitrary code and perform privileged functions.

moderate

I, A

OS or application disruption

Malware may be introduced into the telehealth platform provider environment that disrupts the operating system or applications. Libraries or subsystems may be affected.

low

C

data exfiltration

Sensitive data may be exposed to unauthorized individuals, e.g., via social engineering disclosure or malware that allows threat actors to retrieve data arbitrarily.

moderate

NIST SP 1800-30B: Securing Telehealth Remote Patient Monitoring Ecosystem

94

The table below represents a notional HDO model. As with the telehealth platform provider above, many assumptions have been made about implementing pervasive controls. Table C-5 Threats Applied to the HDO

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

C, I, A

Threat Event

Description

Likelihood

C

phishing

HDO workforce with privileged access may be susceptible to spear phishing attacks.

high

I, A

malicious software

HDO workforce with privileged access to permitting allows malicious software to be introduced into the HDO environment.

moderate

I, A

command and control

HDO workforce with privileged access to permitting allows threat actors to execute arbitrary code and perform privileged functions.

moderate

A

ransomware

Ransomware may be introduced into the HDO environment either as links or attachments found in phishing emails or may be introduced through local media.

moderate

C

credential escalation

Malware may be introduced to the HDO environment that allows threat actors to execute arbitrary code and perform privileged functions.

moderate

I, A

OS or application disruption

Malware may be introduced into the HDO environment that disrupts the operating system or applications. Libraries or subsystems may be affected.

moderate

C

data exfiltration

Sensitive data may be exposed to unauthorized individuals, e.g., via social engineering disclosure or malware that allows threat actors to retrieve data arbitrarily.

high

A

denial of service attack

Flooding network connection with high-volume traffic to disrupt communication in patient home,

high

NIST SP 1800-30B: Securing Telehealth Remote Patient Monitoring Ecosystem

95

C, I, A

Threat Event

Description between home and telehealth platform, or between telehealth platform provider and HDO. Such type of attack could also be used to damage a device, e.g., through accelerated battery depletion.

Likelihood

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

C-5 Threat Sources Threat sources describe those groups or individuals that may expose weaknesses to the RPM infrastructure. Threat sources may take actions that expose or leverage vulnerabilities either through unintentional actions or by actively attacking components within the RPM infrastructure. The following table lists the threat sources identified for this risk assessment. The table is derived from one referenced in NIST Special Publication 800-30 revision 1 (page D-2) [9]. Table C-6 Taxonomy of Threat Sources Type of Threat Source

Description

unintentional–patient

The patient has physical access to biometric devices, workstations, and mobile devices that may be used as part of the RPM patient home environment.

unintentional–care provider (e.g., family member, friend, or others with relationship to the patient)

Care providers or other trusted individuals that may have physical access to biometric devices, workstations, and mobile devices that may be used as part of the RPM patient home environment

unintentional–other actors

Other actors may include clinical or technical staff who may be involved in deploying the RPM infrastructure in the patient’s home and may have local or remote access to data or systems used as part of the overall RPM system. Other actors may interact with

NIST SP 1800-30B: Securing Telehealth Remote Patient Monitoring Ecosystem

Characteristics  able to access components in patient home domain  intend to access components  patient may be targeted by malicious actors.   

able to access components in patient home domain intend to access components individuals may be targeted by malicious actors. able to access components or data as part of the RPM system intend to access the system (e.g., through maintenance or data review) individuals may be targeted by malicious actors or may represent insider threats

96

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

Type of Threat Source

Description components at the software as a service (SaaS) provider or at the HDO location.

intentional—domestic— criminal

Criminal actors may be domestic and are motivated primarily by financial interest. Criminal actors may disrupt RPM deployments either directly or by affecting other devices. Threat actions may be direct or through a chain of attacks.

intentional–nation-state

Some foreign nation-states may want to disrupt another nation’s critical infrastructure. A malicious nation-state’s intent may be difficult to discern as it pertains to an individual. Attacks may be sophisticated and challenging to attribute definitively to a specific attacker.

NIST SP 1800-30B: Securing Telehealth Remote Patient Monitoring Ecosystem

Characteristics where actors have legitimate access; however, component use or data access is not aligned with providing patient care.  ability to access components is not initially provisioned. Criminal actors may perform discovery to identify vulnerable components and may seek means to deploy malicious software that would allow them access and control of the components.  intent often is driven by financial motivation. Criminal elements may seek to obtain information that allows them to obtain funds directly (e.g., credit or bank account numbers) or indirectly (e.g., personal information that would allow criminals to fraudulently obtain financial accounts, to commit insurance fraud, or to sell sensitive information).  ability to access components is not initially provisioned. Nation-state actors may perform discovery to identify vulnerable components, may try to obtain user or administrator credentials, or may seek to deploy malicious software that would allow them access to

97

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

Type of Threat Source

Description

Characteristics and control of the components.  nation-states may obfuscate their identity, posing as legitimate users, other nation-states, criminals, or activists.  nation-states have significant resources to implement complex or advanced attacks.  nation-states may act to disrupt critical infrastructure to either do physical damage or cause sociopolitical discord.  nation-state actors may seek to obtain intellectual property (e.g., designs, formularies, clinical research).

domestic or international–nonnation-state actors (e.g., hacktivists or terrorists)

Non-nation-state actors include those parties that operate as large, disparate organizations that are not necessarily tethered to a government entity. Non-nation-state actors implement attacks based on political or social motivations.

NIST SP 1800-30B: Securing Telehealth Remote Patient Monitoring Ecosystem

ability to access components is not initially provisioned. Non-nationstate actors may perform discovery to identify vulnerable components and may seek to deploy malicious software that would allow them access to and control of the components. non-nation-state actors primarily seek to further a social or political agenda. attacks may seek to disrupt critical infrastructure to either do physical damage or cause sociopolitical discord.

98

C-5.1

Business Processes

Several functions are performed with the RPM system, with those functions performed in the respective scopes: patient data are gathered and stored, and patients interact from the patient home; communications between patients and care teams are routed through the telehealth platform provider, which is cloud hosted; and clinicians receive and interact with patient data from the HDO. Table C-7 identifies these and other business processes that support the RPM functions. This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

Table C-7 RPM Functions and Processes Function interface with biometric devices

Description Patients may connect biometric devices to their bodies. Physical contact occurs between the device and the patient to allow the device to capture health data. Physical interface is a continuous process in that patients may make physical contact with the biometric device on a daily or more frequent basis.

Components Used biometric device

Domain patient home

store biometric data

Biometric data are stored to physical media. Physical media are nonvolatile media types, meaning that data are recorded to the media and available for retrieval after a device has been power cycled. Physical media may consist of flash memory, secure digital (SD) cards, or hard drives associated with the biometric device or a device hosting a healthcare app or application (e.g., a

biometric device

patient home

mobile device laptop desktop dedicated device gateway

NIST SP 1800-30B: Securing Telehealth Remote Patient Monitoring Ecosystem

99

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

Function

Description mobile device, laptop, desktop, or other workstation-type device).

Components Used

Domain

connect to cloud environment

Biometric devices may connect to a local device that uses a telehealth app or application, or the devices may connect to a cloud-hosted telehealth platform provider directly. Connections originate from the patient home connected to the cloudhosted telehealth platform.

biometric device

patient home telehealth platform

connect to HDO environment

conduct video- or audioconferencing

mobile device laptop desktop dedicated device gateway cloud-hosted components

The telehealth platform provider serves as a routing mechanism that connects communications between the patient home and the HDO. The telehealth platform provider handles intransit data as well as manages the underlying technology to enable RPM.

telehealth platform provider

telehealth platform provider

gateway or endpoint devices at the HDO

HDO

Patients may initiate video or audio communication with the clinical care team through the telehealth app or application. Communications will route through the telehealth platform

mobile device laptop desktop cloud-hosted components HDO mobile devices HDO workstations

patient home

NIST SP 1800-30B: Securing Telehealth Remote Patient Monitoring Ecosystem

telehealth platform provider HDO

100

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

Function

Description provider and be routed to the HDO.

Components Used

Domain

remote configuration or settings updates

HDOs may periodically push configuration or other settings updates to biometric devices. The connection initiates from the HDO and connects to the biometric device located in the patient home.

HDO-hosted servers biometric devices

HDO

review patient biometric data

Physicians access patient biometric data and review and analyze them.

HDO workstation HDO mobile device

HDO

add biometric data to clinical notes

Biometric data may not ingest directly to an electronic health record (EHR) system. A physician may need to manually enter information based on the biometric data to the EHR.

HDO workstation EHR

HDO

patient home

C-6 Vulnerabilities Below is a customized application on identifying vulnerabilities that aggregates vulnerabilities identified in NIST SP 800-30 Revision 1 [9]. As noted in the document, a vulnerability is a deficiency or weakness that a threat source may exploit, resulting in a threat event. The document further describes that vulnerabilities may exist in a broader context, i.e., that they may be found in organizational governance structures, external relationships, and mission/business processes. The following table enumerates those vulnerabilities, using a holistic approach, and represents those vulnerabilities that this project identified and for which it offers guidance. For further description, readers should reference NIST SP 800-30 Revision 1 [9].

NIST SP 1800-30B: Securing Telehealth Remote Patient Monitoring Ecosystem

101

Table C-8 Vulnerability Taxonomy

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

Vulnerability Description

Vulnerability Severity

Predisposing Condition

Pervasiveness of Predisposing Condition

out-of-date software

high

Systems may not have patches deployed in a timely fashion, or software may not be validated to assure that applications may operate appropriately should the underlying operating system receive new updates.

high

permissive configuration settings

high

Underlying operating systems or security components (e.g., firewall) may have configuration settings that allow actions that exceed the minimum necessary to operate the application.

high

unmanaged or improperly managed credentials

high

Applications may use service or other privileged accounts to operate, or operating systems may have privileged accounts that have expansive access to the host system(s). These access privileges may exceed the minimum necessary to operate applications.

high

unprotected data

high

Data on systems may lack restrictions that limit accessibility.

high

failing or missing integrity or

high

Data path may lack end-to-end data

high

NIST SP 1800-30B: Securing Telehealth Remote Patient Monitoring Ecosystem

102

Vulnerability Description authenticity verification

Vulnerability Severity

Predisposing Condition

Pervasiveness of Predisposing Condition

integrity or authenticity verification.

C-7 Threat Modeling This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

Thus far, this practice guide has discussed several elements that make up an attack. Threats involve threat actors that may leverage vulnerabilities found in components. Components represent end-point devices found in the overall system. Components are made up of several subcomponents. The threatmodeling exercise described below identifies adverse actions that may expose vulnerabilities at the subcomponent level. This practice guide considers that threats may include multiple actions taken that ultimately result in risk. These multiple actions are described herein as adverse actions. A threat may involve one or more adverse actions leveraging vulnerabilities at the subcomponent level that then result in risk. The patient home environment is used as a representative domain by which the threat-modeling exercise is applied. Practitioners may wish to perform a similar, granular level of analysis for other domains in their deployment. For the RPM solution, components are identified in three distinct domains: the patient home, the telehealth platform provider, and the HDO. This section describes a means by which threats may occur contextually. Adverse actions that align with threats may target specific subcomponents, with different risk outcomes based on the domain within which the threat actor executes the attack. Practitioners should note that while this practice guide does not apply any particular threat-modeling methodology, several are available that provide guidance for performing similar exercises for an organization’s environment.

C-7.1 Modeling Threats to the Patient Home The patient home domain poses several challenges when considering threats. For example, patients or care providers may not have the resources or technology background to address these threats independently. Telehealth platform providers and HDOs may not have the ability to manage the patient home environment entirely. Patients may have devices that are unrelated to RPM operating in their home environment. Other individuals within the patient home may have physical access to RPM devices. Components that may be present in the RPM system’s environment are outlined in Table C-9.

NIST SP 1800-30B: Securing Telehealth Remote Patient Monitoring Ecosystem

103

Table C-9 Components in the Patient Home Environment

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

Component

Description

Communicates with

Provisioned by

biometric device

A sensor device that interfaces with the patient and captures biometric data that are conveyed to the clinician

patient (direct, tactile interface)

telehealth platform

interface device wireless personal area network (PAN) (e.g., Bluetooth, WiFi)

HDO

telehealth platform provider (Wi-Fi) interface device

Wi-Fi access point

A device that potentially retrieves data from biometric devices and is used as a communications device by which patientclinician communications may occur. The device may be a mobile device such as a tablet or a connected phone running a dedicated application, may be a full-feature device such as a laptop or desktop workstation, or may be a purpose-designed device.

biometric device telehealth platform (e.g., near-field provider communication[NFC], Bluetooth, Wi-Fi) HDO

A device that provides the RPM environment a wireless means to communicate with devices by using internet protocols

biometric device

telehealth platform provider

interface device unrelated equipment

NIST SP 1800-30B: Securing Telehealth Remote Patient Monitoring Ecosystem

telehealth platform provider HDO patient

104

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

Component

Description

Communicates with

Provisioned by

internet router

A device that allows computing devices in the home to communicate via the internet over broadband infrastructure (e.g., cable, fiber-optic, telephone)

biometric device

patient

A device that is not part of the RPM solution; however, it may have communications capabilities to components. These devices may include patient-owned devices such as personal computers, mobile devices, or connected home devices

biometric device

Personally-owned device

unknown device

A device belonging to individuals other than the patient. This may include guests or unknown individuals.

interface device unrelated equipment

patient

interface device internet router Wi-Fi access point

unknown

unknown individuals

biometric device interface device internet router Wi-Fi access point

The RPM solution deployed in the patient home is not a closed system. Elements that may be provisioned by the patient include Wi-Fi or cellular access points and the internet router. Further, the patient may have other devices on the home network. These may include connected home devices, personal computers, mobile devices, and gaming and entertainment systems. The biometric device may consist of several subcomponents. Biometric devices may have PAN interfaces that support short-distance communication (e.g., Bluetooth). Biometric devices may also support Wi-Fi

NIST SP 1800-30B: Securing Telehealth Remote Patient Monitoring Ecosystem

105

connectivity. A biometric device has a tactile interface that makes physical contact with an individual. There may be a display that acts as a user interface, and there may be storage media embedded in the device. There may be onboard storage. Physical external interfaces are ports for data communication (e.g., Universal Serial Bus [USB]), acceptance of removable media (e.g., SD card), and power.

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

Threats may be introduced based on the proximity of the subcomponent, as described in Table C-10. Threats that involve physical interaction with the subcomponent may be regarded as "local". Threats that originate from an external network may be regarded as "remote". Threats that use communications that are contained within the local environment may be described as "near remote". Table C-10 Biometric Device Subcomponent Breakdown Subcomponent

Adverse Action

Proximity

C, I, A

Adverse Outcome

Unmitigated Likelihood

tactile interface

An individual other than the patient attaches the biometric device and introduces nonpatient data.

local

I

biometric data would be false; do not pertain to the patient.

high

display

An individual other than the patient may be able to navigate the user interface and view patient biometric data.

local

C

unauthorized individuals may have access to biometric data.

high

display

The display may be damaged so that navigation is not possible.

local

A

biometric device usage degraded

high

onboard storage

Storage media that maintains biometric device system files may be damaged or made unavailable.

local

A

biometric device rendered inoperative

low

NIST SP 1800-30B: Securing Telehealth Remote Patient Monitoring Ecosystem

106

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

Subcomponent

Adverse Action

Proximity

C, I, A

Adverse Outcome

Unmitigated Likelihood

data communication port

An individual may access the biometric device and expose a subsystem (e.g., operating system).

local

I, A

exposing a subsystem such as an operating system may enable a malicious actor to escalate privileges and modify, install, or execute arbitrary code.

low

personal area network

An individual may retrieve communications between the biometric device and the interface device.

near remote

C

unauthorized individuals may have access to biometric data.

low

removable media

An individual may be able to leverage removable media and extract data from the biometric device.

local

C

unauthorized individuals may have access to biometric data.

moderate

removable media

An individual may be able to introduce removable media to convey malicious software.

local

I, A

unauthorized individuals may introduce unauthorized or malicious software to the biometric device and alter functionality or render the device inoperative.

moderate

NIST SP 1800-30B: Securing Telehealth Remote Patient Monitoring Ecosystem

107

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

Subcomponent

Adverse Action

Proximity

C, I, A

Adverse Outcome

Unmitigated Likelihood

cellular communications

Cellular communications may be damaged.

local; remote

A

cellular communications may be inoperative.

low

cellular communications

Cellular communications may become compromised.

local; remote

A

cellular data may be exposed to unauthorized individuals.

low

Wi-Fi communications

Wi-Fi communications may be damaged.

local

A

Wi-Fi communications may be inoperative.

low

Wi-Fi communications

Wi-Fi communications may be compromised.

local; remote

C

data carried over Wi-Fi may be exposed to unauthorized individuals.

moderate

The interface device may be a connected phone, tablet, laptop, or desktop device. Depending on the device type and manufacturer, subcomponents may vary. The first threat model profile offered below assumes that the interface device is a connected phone or tablet. Connected phones and tablets are assumed to have similar characteristics for the purposes of developing the threat model considered in this practice guide. Table C-11 Interface Device Subcomponent Breakdown Subcomponent

Adverse Action

Proximity

C, I, A

Adverse Outcome

Unmitigated Likelihood

display

Display may become damaged.

local

A

device may be inoperable or unusable

high

display

An unauthorized individual who has access to the display may be able to obtain

local

A

biometric data lost

low

NIST SP 1800-30B: Securing Telehealth Remote Patient Monitoring Ecosystem

108

Subcomponent

Adverse Action

Proximity

C, I, A

Adverse Outcome

Unmitigated Likelihood

biometric data (e.g., fingerprint).

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

data access port

An individual may access the mobile device and expose a subsystem (e.g., operating system).

local

I, A

unauthorized low code may be introduced that compromises the device integrity or renders the device inoperable for intended purposes

operating system

The operating system may be susceptible to known vulnerability exposure.

local; remote

C, I, A

vulnerability exposure may allow unauthorized removal of data, allow introduction of unauthorized code that could compromise the device operational integrity, or render the device inoperable

moderate

RPM app

The RPM app may not be patched to current versions and may allow exposure to known vulnerabilities.

local; remote

C, I, A

apps on the device may include flaws or vulnerabilities that result in unauthorized data exposure or compromise to an app or to device operational integrity or that

moderate

NIST SP 1800-30B: Securing Telehealth Remote Patient Monitoring Ecosystem

109

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

Subcomponent

Adverse Action

Proximity

C, I, A

Adverse Unmitigated Outcome Likelihood render the app or device inoperable

other apps

Apps may be installed on the device that include unauthorized code.

local; remote

C

unauthorized actors may exfiltrate data from the device

moderate

other apps

Apps may be installed on the device that include unauthorized code.

local; remote

I, A

unauthorized actors may disrupt the device’s functionality

moderate

onboard storage media

Onboard storage media may become damaged.

local

A

device may become inoperative or unable to obtain or transmit biometric data

low

removable media

A device that allows removable media may enable a means by which files may be moved or copied.

local

C

data may be exfiltrated

low

removable media

A device that allows removable media may allow code installation.

local

C, I, A

unauthorized software is introduced on the device

low

camera

The camera may become damaged, rendering videoconferencin g inoperative.

local

A

images and videos may not be obtained

moderate

NIST SP 1800-30B: Securing Telehealth Remote Patient Monitoring Ecosystem

110

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

Subcomponent

Adverse Action

Proximity

C, I, A

Adverse Outcome

Unmitigated Likelihood

camera

Malicious actors may be able to compromise subsystems and allow unauthorized control of camera functions.

remote

C

sensitive video data may be exposed

moderate

audio microphone

Audio microphone may become damaged.

local

C

audio communication may not function appropriately

low

cellular communications

Cellular communications may be damaged.

local

A

cellular communications may be inoperative

low

cellular communications

Cellular communications may become compromised.

local; remote

C

cellular data may be exposed to unauthorized individuals

low

Wi-Fi communications

Wi-Fi communications may be damaged.

local

A

Wi-Fi communications may be inoperative

low

Wi-Fi communications

Wi-Fi communications may be compromised.

local; remote

C

data carried over Wi-Fi may be exposed to unauthorized individuals

moderate

Table C-12 Laptop Subcomponent Breakdown Subcomponent

Adverse Action

Proximity

C, I, A

Adverse Outcome

Unmitigated Likelihood

data access port

An individual may access the mobile

local

I, A

unauthorized code may be

low

NIST SP 1800-30B: Securing Telehealth Remote Patient Monitoring Ecosystem

111

Subcomponent

Adverse Action

Proximity

C, I, A

Adverse Outcome introduced that compromises the device integrity or renders the device inoperable for intended purposes

Unmitigated Likelihood

device and expose a subsystem (e.g., operating system). This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

display

An unauthorized individual who has access to the display may be able to obtain biometric data (e.g., fingerprint).

local

A

biometric data lost

low

operating system

The operating system may not be patched to current versions and may allow known vulnerability exposure.

local; remote

C, I, A

vulnerability exposure may allow unauthorized removal of data, allow introduction of unauthorized code that could compromise the device operational integrity, or render the device inoperable

moderate

RPM application

The RPM application may not be patched to current versions and may allow known

local; remote

C, I, A

applications on the device may include flaws or vulnerabilities that result in unauthorized data exposure,

moderate

NIST SP 1800-30B: Securing Telehealth Remote Patient Monitoring Ecosystem

112

Subcomponent

Adverse Action

Proximity

C, I, A

Adverse Outcome compromise the app or device operational integrity, or render the application or device inoperable

Unmitigated Likelihood

vulnerability exposure.

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

other applications

Applications may be installed on the device that include unauthorized code.

local; remote

C

unauthorized actors may exfiltrate data from the device

moderate

other applications

Applications may be installed on the device that include unauthorized code.

local; remote

C

unauthorized actors may exfiltrate data from the device

moderate

onboard storage media

Onboard storage local media may become damaged.

A

device may become inoperative or unable to obtain or transmit biometric data

low

removable media

A device that allows removable media may allow code installation.

local

I

unauthorized software is introduced on the device

low

camera

The camera may local become damaged, rendering videoconferencing inoperative.

A

images and videos may not be obtained

moderate

camera

Unauthorized actors may be able to

C

sensitive video data may be exposed

moderate

remote

NIST SP 1800-30B: Securing Telehealth Remote Patient Monitoring Ecosystem

113

Subcomponent

Adverse Action

Proximity

C, I, A

Adverse Outcome

Unmitigated Likelihood

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

compromise subsystems and allow unauthorized control of camera functions. audio microphone

Audio local microphone may become damaged.

A

audio communication may not function appropriately

low

Wi-Fi communications

Wi-Fi communications may be damaged.

local

A

Wi-Fi communications may be inoperative

low

Wi-Fi communications

Wi-Fi communications may be compromised.

local; remote

C

data carried over Wi-Fi may be exposed to unauthorized individuals

moderate

Table C-13 Desktop Subcomponent Breakdown Subcomponent

Adverse Action

Proximity

C, I, A

Adverse Outcome

Unmitigated Likelihood

data access port

An unintended device may obtain communications channels by using data access ports (e.g., USB).

local

I, A

unauthorized code may be conveyed via the data access port and expose or corrupt subsystem libraries (e.g., operating system)

low

display port

The display port may become

local

A

information may not be displayed;

low

NIST SP 1800-30B: Securing Telehealth Remote Patient Monitoring Ecosystem

114

Subcomponent

Adverse Action

Proximity

C, I, A

Adverse Outcome interaction with the system may be prevented

Unmitigated Likelihood

physically damaged.

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

operating system

The operating system may not be patched to current versions.

local; remote

C, I, A

vulnerabilities may persist

moderate

RPM application

The RPM application may not be patched.

local; remote

C, I, A

vulnerabilities may persist

moderate

other applications

Applications may be installed on the device that include malicious code.

local; remote

C

unauthorized actors may exfiltrate data from the device

moderate

other applications

Applications may be installed on the device that include malicious code.

local; remote

C

unauthorized actors may exfiltrate data from the device

moderate

onboard storage media

Onboard storage local media may become damaged.

A

device may become inoperative or unable to obtain or transmit biometric data

low

removable media

A device that allows removable media may allow code installation.

local

C

unauthorized software is introduced on the device

low

camera

The camera may local become damaged, rendering videoconferencing inoperative.

A

images and videos may not be obtained

moderate

NIST SP 1800-30B: Securing Telehealth Remote Patient Monitoring Ecosystem

115

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

Subcomponent

Adverse Action

Proximity

C, I, A

Adverse Outcome

Unmitigated Likelihood

camera

Unauthorized actors may be able to compromise subsystems and allow unauthorized control of camera functions.

remote

C

sensitive video data may be exposed

moderate

audio microphone

Audio local microphone may become damaged.

A

audio communication may not function appropriately

low

Ethernet network port

Ethernet port may be damaged.

local

A

Wi-Fi communications may be inoperative

low

Ethernet network port

Ethernet communications may be compromised.

local; remote

C

data carried over Wi-Fi may be exposed to unauthorized individuals

moderate

Wi-Fi communications

Wi-Fi communications may be damaged.

local

A

Wi-Fi communications may be inoperative

low

Wi-Fi communications

Wi-Fi communications may be compromised.

local; remote

C

data carried over Wi-Fi may be exposed to unauthorized individuals

moderate

C-7.2 Linking Threats to Adverse Actions For the threat-modeling exercise, this practice guide examines concepts at a granular level. The exercise examined the concept that threats may be evaluated at the subcomponent level through introduction of

NIST SP 1800-30B: Securing Telehealth Remote Patient Monitoring Ecosystem

116

adverse actions. The adverse actions that the threat-modeling exercise included in themselves do not represent the enterprise threat environment but, rather, events that may occur that, in combination, may be how threats are found in the three domains that the practice guide describes as composing the RPM architecture. Table C-14 Threat Event to Adverse Action Mapping This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

C, I, A

Threat Event

Attack Description

Target Component

Adverse Action

C

phishing

A social engineering attack that solicits an authorized user to perform an action that is beyond intended function. Phishing typically is delivered via an email that falsely claims authenticity. A phishing email may contain payloads such as attachments or links that then run arbitrary code.

interface device mobile device laptop desktop

escalation of privilege

I, A

unauthorized software

Unauthorized software may include arbitrary code that compromises system integrity or system stability.

biometric device interface device laptop desktop

system integrity compromise: system availability degraded

I, A

command and control

Unauthorized software is introduced that allows unintended actors to initiate connections to the target device.

biometric device interface device laptop desktop

system integrity compromise: system availability degraded

A

ransomware

A form of unauthorized software that prevents legitimate access to the system and resources

interface device laptop desktop

system availability degraded

C

credential escalation

Unauthorized individuals can leverage credentials and view sensitive data.

interface device laptop desktop

information exposure

NIST SP 1800-30B: Securing Telehealth Remote Patient Monitoring Ecosystem

117

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

C, I, A

Threat Event

Attack Description

Target Component

Adverse Action

I, A

OS or application disruption

Resource requests or application of unauthorized software may compromise the integrity or stability of the RPM application.

interface device laptop desktop

system integrity compromise: system availability degraded

C

data exfiltration

Unauthorized users may be biometric device able to remove sensitive interface device data from the device. laptop desktop

information exposure

NIST SP 1800-30B: Securing Telehealth Remote Patient Monitoring Ecosystem

118

Appendix D

Problematic Data Actions and Risks

While the project team was writing this practice guide, the National Institute of Standards and Technology (NIST) published the NIST Privacy Framework, Version 1.0 [5]. Privacy concerns should be addressed particularly in healthcare environments. The project team examined the NIST Privacy Framework and included approaches that lead toward better understanding and managing the privacy risks that may be present in remote patient monitoring (RPM) deployments. This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

Structurally, the NIST Privacy Framework is like the NIST Cybersecurity Framework. Both frameworks should be applied when evaluating enterprise programs and developing mitigation strategies. Applying the Privacy Framework does not supersede the NIST Cybersecurity Framework. Rather, the Privacy Framework provides organizations with information to understand privacy-specific risks. For more information about the NIST Privacy Framework, healthcare delivery organizations (HDOs) should review NIST Privacy Framework: A Tool for Improving Privacy through Enterprise Risk Management, Version 1.0 [5].

D-1 Privacy Risk Assessment Methodology The project team applied the NIST Privacy Risk Assessment Methodology (PRAM) to conduct a privacy risk assessment for the RPM architecture. The PRAM helps an organization analyze privacy risks and facilitates communication regarding how it is managing privacy risks to achieve business/mission objectives. Processing can include collection, retention, logging, analysis, generation, transformation, merging, disclosure, transfer, and disposal of data. The PRAM also uses the privacy risk model and privacy engineering objectives described in NIST Internal Report 8062 [36] to analyze data processing for problematic data actions. A problematic data action is any data processing operation that could lead to an adverse effect, or problem, for individuals. The occurrence or potential occurrence of problematic data actions is a privacy event. For this RPM solution, the PRAM helped elucidate how RPM solutions can present privacy concerns for individuals. The PRAM, being a risk assessment, also supports the risk assessment task in the Prepare step of the NIST Risk Management Framework as discussed in Section C-1 of this guide. The privacy events identified are discussed in Section C-2. A blank version of the PRAM is available for download on NIST’s website [7]. When conducting the PRAM for this RPM solution, metadata was not assessed as it is out of scope for this project; therefore, this practice guide does not provide guidance to help an organization with securing any possible metadata if it may be leaked on devices within the telehealth ecosystem. An organization should consider the risk that could result from this incident occurring in its telehealth ecosystem. Figure D-1 depicts the privacy view of the RPM solution dataflow and was used to conduct the privacy risk assessment. The dataflow is broken into seven data processing activities (described here as “data actions” and appearing in the diagram as a sequence labelled from 1 to 7). The dataflow shows the

NIST SP 1800-30B: Securing Telehealth Remote Patient Monitoring Ecosystem

119

relationships between the key operators throughout the full lifecycle of the solution as well as the types of data processing that occur as the data moves between operators. The operators include the patient, biometric device, RPM mobile device, biometric device vendor, telehealth platform, and the HDO (comprised of the Clinician and electronic health record). Symbols are used to depict the types of data actions performed, including collection, retention/logging, generation/transformation, disclosure/transfer, disposal. This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

Data Action 1 shows the patient connecting to a biometric device so that it can begin collecting readings. Data Action 2 shows that the biometric data generated by the patient is read by and retained on the biometric device before being transmitted to either the RPM Mobile Device (via Bluetooth or Wi-Fi) or the Biometric Device Vendor (via cellular network) when a retrieval request is sent. Data Action 3 describes two possible paths for collecting biometric data, one via an RPM Mobile Device, and another via the Biometric Device Vendor. The RPM Mobile Device or Biometric Device Vendor collects and retains the biometric data and then forwards the biometric data to the Telehealth Platform. Data Action 4 shows that patient data may be generated or transformed as the Telehealth Platform evaluates and correlates data and alerts the clinician when a patient data threshold is passed. The Telehealth Platform also maintains a history of readings and trends. Data Action 5 shows that the Clinician accesses the Telehealth Platform, evaluates the patient data and determines whether and how to respond, which may generate additional patient data. When needed, the Clinician also transfers patient data to update the EHR for later reference. Data Action 6 shows that the Clinician may meet with the patient using an PRM Mobile Device. This interaction may result in collection and of additional information that is stored in the EHR. Data Action 7 shows that HDOs may choose to initiate a patient survey The diagram shows that the Data Actions 4-7 are out of the scope of this solution and the privacy risk assessment.

NIST SP 1800-30B: Securing Telehealth Remote Patient Monitoring Ecosystem

120

Figure D-1 Privacy View of RPM Solution Dataflow

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

D-2 Problematic Data Actions and Mitigations The NIST Privacy Framework refers to the concept of problematic data actions, which derives from the NIST PRAM. Problematic data actions are discovered by conducting a privacy risk assessment and analyzing the likelihood that an operation performed by a system would create a problem for individuals when processing data and the impact of the problematic data action should it occur. This section provides representative problematic data actions identified in the RPM architecture and the mitigations that an organization may use to reduce or prevent potential risk. The discussion of problematic data actions is structured as follows: 

Privacy Risk: descriptive name for the issue that can arise in the RPM solution from data processing

Data Action: a data life-cycle operation in the RPM solution, including collection, retention, logging, generation, transformation, use, disclosure, sharing, transmission, and disposal

NIST SP 1800-30B: Securing Telehealth Remote Patient Monitoring Ecosystem

121

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

Problematic Data Action: a data action in the RPM solution that could cause an adverse effect for individuals (based on the NIST Catalog of Problematic Data Actions and Problems)

Potential Problems for Individuals: discussion regarding the nature of the problematic data action and the specific privacy problems that can arise for patients (based on the NIST Catalog of Problematic Data Actions and Problems)

Mitigations: examples of mitigations for the problematic data action, including those that this RPM solution addresses as well as other mitigations that organizations may wish to consider beyond the direct capabilities built into their RPM solution

D-2.1 Privacy Risk 1: Storage and movement of data create multiple points of potential exposure after data are collected from the patient Data Action: Patients’ readings are taken from the biometric device and forwarded to the telehealth platform. Problematic Data Action: Insecurity Potential Problems for Individuals: Data shared between devices in the RPM data ecosystem may not be protected at rest or in transit. Data may include sensitive information. Unauthorized data disclosure may result in patient harm. For example, disclosure could lead to dignity loss or embarrassment or may cause patients to distrust the RPM system. The solution relies on communication between the patient’s biometric device(s) and the HDO. Biometric devices forward the information to the HDO via the telehealth platform provider. In this solution, data flow from the biometric device either directly to the telehealth platform provider or are routed via an RPM mobile device via Bluetooth, Wi-Fi, or over the cellular network. Each device, system, and dataflow in the process introduces an exposure point, several of which would not arise in a traditional healthcare setting, such as a doctor’s appointment (e.g., if the patient’s reading is taken in a doctor’s office). Any failure to protect data stored on the biometric and RPM mobile devices and forwarded may allow unauthorized individuals to view sensitive information. In this event, someone other than a patientapproved individual can access data that are unencrypted on the biometric device or RPM mobile device or during forwarding. The patient may experience dignity loss due to their health information being exposed and may also experience loss of trust for the HDO and RPM mobile device. Mitigation(s): RPM Solution Mitigation: Physical device security is out of scope for this lab solution. Protect data at rest and in transit between devices and telehealth platforms.

NIST SP 1800-30B: Securing Telehealth Remote Patient Monitoring Ecosystem

122

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

Protecting data on the biometric device, e.g., by using encryption, prior to moving it to the telehealth platform and using encrypted connections to protect the contents of data in transit reduces the risk of exposure. Robust network security controls should be in place to help protect data in transit. For example, firewalls and network access control will help secure the data against ransomware, malware, and other attacks. If data are not encrypted, unauthorized individuals may be able to retrieve the data, which can lead to inappropriate use of information. Encryption methods should be used in preventing health information disclosure. Additional Privacy Mitigations for Organizations to Consider: Develop and adopt enterprise encryption policies. Policies should be created, developed, and adopted for systematically categorizing and classifying all healthcare data, including metadata, no matter where the data are stored.

D-2.2 Privacy Risk 2: Biometric device types can indicate patient health problems that individuals would prefer not to disclose beyond their healthcare provider Data Action: Patients are provided one or more biometric devices that monitor biometric data and send that data to their healthcare providers to help assess the physical health condition of the patient between visits with the provider. Problematic Data Action: Unanticipated Revelation Potential Problems for Individuals: Patients with given medical conditions may use certain biometric devices, alone or in combination. If communications from these devices are accessed by unauthorized individuals, they may disclose particular health problems. For example, a glucometer can indicate that a patient is being monitored for diabetes. This assumption could be more obvious if that same patient is also known to be using a blood pressure monitor, weight scale, and activity tracker. Patient sensitivities regarding their health status can vary widely. Unauthorized individuals may be able to determine a patientʼs medical condition based on knowing a combination of factors. For example, knowledge of the device type and the biometric data may enable individuals to conclude the patientʼs health condition. Revealing a health condition that a patient would prefer not to disclose or disclosure of a patientʼs medical treatment and their course of treatment outside their healthcare provider can lead to dignity loss, such as embarrassment, emotional distress, and loss of trust in the HDO and RPM system. This could damage the relationship with a patient, including losing the opportunity for the HDO to continue providing care. Intercepting communications sessions may have a lower likelihood of occurrence than aggregated data compromise.

NIST SP 1800-30B: Securing Telehealth Remote Patient Monitoring Ecosystem

123

When biometric devices participate in an RPM solution, they may share device metadata (e.g., device identifiers, device type, or manufacturer) as they communicate with the vendor, telehealth platform, or the HDO. This device metadata may reveal the information that indicates a patient condition (e.g., type of device). Additionally, communications may be vulnerable to eavesdropping, which could give away the device type. Evaluating device metadata and communications should be included in the organization’s risk assessment. This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

Mitigation(s): RPM Solution Mitigation(s): Protect data transmitted between parties and in storage. Data-in-transit protection, e.g., by encrypting communications channels, reduces the risk of compromise of information transmitted between parties. Reducing the risk of compromise and any resulting exposures reduces the risk of unintentional exposure of the information. Biometric devices communicate through a mobile device that uses a Bluetooth connection, and the RPM solution assumes that these devices are deployed using an appropriate encryption mode [25] [37]. The RPM solution uses devices that are equipped to communicate over 4G long-term evolution (LTE), which uses asymmetric encryption between the device and the cellular tower. Additionally, all data at rest is protected with AES-256 encryption [28]. Limit or disable access to data. Conduct a system-specific privacy risk assessment to determine how access to data in the telehealth platform provider can be limited. Using access controls to limit staff access to biometric and patient data can be important in preventing associating health conditions with specific individuals.

D-2.3 Privacy Risk 3: Incorrect data capture of readings by devices may impact quality of patient care Data Action: The RPM solution relies on the patient to take readings by using the patient’s assigned biometric device(s) when required according to their care plan. Problematic Data Action: Distortion Potential Problems for Individuals: Devices may be inaccurately applied by the patient (e.g., not properly using or inadvertently changing settings), which can impact the ability of a biometric device to take proper readings. Anomalies may also be introduced by other individuals who may have physical access to the device (e.g., allowing someone other than the patient to use the device), which may introduce biometric readings other than the patientʼs into the system. Data integrity may be compromised, causing confusion regarding the patient’s actual health and possibly leading to physical harm to the patient.

NIST SP 1800-30B: Securing Telehealth Remote Patient Monitoring Ecosystem

124

Mitigation(s): RPM Solution Mitigation(s): Physical device security is out of scope for this lab solution. Ultimately, responsibility for monitoring patient data, including identifying anomalies, falls on the clinician. Additional Privacy Mitigations for Organizations to Consider: This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

Educate patients regarding practices for handling biometric device(s) and the importance of following their monitoring plan. Educating patients regarding how their interactions with the biometric devices assigned to them affect the quality of the data provided to the telehealth platform provider, HDO, healthcare provider, and ultimately the quality of care they receive and their health safety will encourage them to use the biometric devices as designed and intended.

D-2.4 Privacy Risk 4: Aggregated data may expose patient information Data Action: Patients use one or more biometric devices to monitor the condition of their health. The biometric data generated are transmitted through multiple entities, including cellular or broadband internet providers, biometric device vendors, telehealth platform providers, cloud service providers, and HDOs before reaching the healthcare provider. Problematic Data Action: Re-identification Potential Problems for Individuals: The RPM architecture integrates data from multiple organizations, each of which may have different data that pertain to the patient. The biometric data generated by the solution indicates an individual’s health status. Aggregation of biometric data with patient identifiers associates information about the patient that, if revealed to an entity other than their healthcare provider and care team, may result in dignity losses, such as embarrassment or emotional distress, as well as loss of trust in the HDO and provider. Mitigation(s): RPM Solution Mitigation(s): Combine biometric data with patient identifiers only when operationally required. The device manufacturer may aggregate data received from patients. Biometric data do not include patient identifiers but will include device identifiers. The telehealth platform provider may associate the biometric data to patients by using device identifiers. In this RPM solution, the telehealth platform provider does not combine these data until the point at which it is necessary to perform patient analytics that enable the healthcare delivery organization to manage the patient’s care. The

NIST SP 1800-30B: Securing Telehealth Remote Patient Monitoring Ecosystem

125

telehealth platform provider uses a biometric device identifier to correlate a patient with the biometric data that a device transmits. Protect data transmitted between parties and in storage.

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

Data protection, e.g., by using encryption, reduces the risk that compromised data can be easily used and combined with other data to re-identify patients. Biometric devices communicate through a mobile device that uses Bluetooth connections, and the RPM solution assumes that these devices are deployed using an appropriate encryption mode [25] [37]. The RPM solution uses devices that are equipped to communicate over 4G LTE, which uses asymmetric encryption between the device and the cellular tower. Additionally, all data at rest is protected with AES-256 encryption.

D-2.5 Privacy Risk 5: Exposure of patient information through multiple providers of system components increases the likelihood of exposure of patient data to unintended recipients Data Action: Data about individuals and their devices flow between various applications and analytical tools, some of which are managed by third parties. Problematic Data Action: Unanticipated Revelation Potential Problems for Individuals: Multiple organizations work together to provide individual components of the RPM solution, and each organization that plays a role in data processing represents an exposure point for patient information. Patient biometric data travel from devices to the HDO through device vendors and telehealth platform providers over cellular and broadband networks. Some of the data also flows through cloud solutions. These third parties beyond the HDO and patient’s provider may conduct system monitoring, analytics, and other operational activities as part of the solution. System administrators have access to otherwise private healthcare information through knowledge of biometric device types and the data they generate, which may reveal information about patients that results in dignity losses, such as embarrassment or emotional distress. Data transmission about patients and their biometric devices among a variety of different parties could be confusing for patients who might not know who has access to information about them. This transmission could reveal personal information about the patient to parties they would not expect to have such information. This lack of patient visibility and awareness of data-sharing practices may also cause patient loss of trust in the provider. Additionally, the communications between RPM devices and systems generate metadata that may pose additional risk of exposure. For example, device identifiers in some contexts may indicate the type of device that is communicating, which can provide insights into a patient’s condition even without viewing

NIST SP 1800-30B: Securing Telehealth Remote Patient Monitoring Ecosystem

126

the data transmitted. Metadata was not evaluated as part of this solution; however, organizations planning to implement RPM solutions should include an evaluation of metadata in their risk assessment. Mitigation(s): RPM Solution Mitigation(s): Combine biometric data with patient identifiers only when operationally required. This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

The device manufacturer may aggregate data received from patients. Biometric data do not include patient identifiers, however, will include device identifiers. The telehealth platform provider may associate the biometric data to patients by using device identifiers. In this RPM solution, the telehealth platform provider does not combine these data until the point at which it is necessary to perform patient analytics that enable the healthcare delivery organization to manage the patient’s care. The telehealth platform provider uses a biometric device identifier to correlate the biometric data with a patient. Protect data transmitted between parties and in storage. Data protection, e.g., using encryption, reduces the risk of compromise of information transmitted between parties. Biometric devices communicate through a mobile device that uses Bluetooth connections, and the RPM solution assumes that these devices are deployed using an appropriate encryption mode. The RPM solution uses devices that are equipped to communicate over 4G LTE, which uses asymmetric encryption between the device and the cellular tower [25] [37]. Additionally, all data at rest is protected with AES-256 encryption. Limit or disable collection of specific data elements. Conduct a system-specific privacy risk assessment to determine what elements can be limited. The RPM solution sends only biometric and device data from the device to the RPM interface and vendors and excludes identifying information about the patient. This would limit insight into patient health status by outsiders or telehealth platform provider administrators if the security of the information is compromised. Additional Privacy Mitigations for Organizations to Consider: Limit or disable access to data. Conduct a system-specific privacy risk assessment to determine how access to data can be limited. Using access controls to limit staff access to compliance information, especially when associated with patients, can be important in preventing association of specific biometric data with individuals. Use contracts to limit third-party data processing.

NIST SP 1800-30B: Securing Telehealth Remote Patient Monitoring Ecosystem

127

Establish contractual policies to limit data processing by third parties to only the processing that facilitates delivery of security services and to no data processing beyond those explicit purposes.

D-3 Additional Program Mitigations Applicable Across Various Data Actions

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

Organizations that deploy RPM solutions will conduct their own risk assessment and determine what mitigations are most appropriate for their environment, including organizational activities outside the direct control of their RPM solution. This section includes several examples of mitigations that may be common across the organization and is not intended to be all-encompassing. Mitigations: Ensure that privacy notices address end-to-end dataflows in the RPM solution between patient and provider. RPM solutions empower patients as active participants in their healthcare. Privacy notices—information such as the data collected about the patient, the reason they are collected, how they are processed by an organization, how they are protected, and how long an organization plans to use them—are one way that HDOs can help patients understand their relationship and expectations with an organization. Privacy notices are also a precursor to requesting consent so that patients understand what agreements they are making and how to withdraw consent at any time during the program. Effective notices that cover the RPM solution should be specific enough to help patients understand the PRM solution and should be written in clear terms that are easily understood by any individuals (i.e., individuals do not need healthcare, RPM, or privacy expertise to interpret the privacy notice). Patients may not be aware of or easily able to discern what is happening with the information generated by their biometric device(s), such as analytics and trend analyses that telehealth platform providers can conduct and how a provider may use this information for their care. Information regarding the RPM solution that includes a discussion of privacy helps patients better understand how the system processes their data, which enhances predictability. One example of providing an effective RPM privacy notice would be to create an RPM website or pamphlet, separate from the overall operational privacy notice that an HDO may have, that explains the RPM program. Provide a support point of contact. Providing patients with a point of contact in the organization who can respond to privacy inquiries and concerns regarding the RPM solution helps patients better understand how the system processes their data, which enhances predictability. Define and communicate clear retention policies. To minimize security and privacy risk to patients (e.g., deciding based on outdated data that could impact the quality of care provided through an RPM solution), HDOs should use the results of their risk assessment to determine how each solution component impacts their retention policies for each step in

NIST SP 1800-30B: Securing Telehealth Remote Patient Monitoring Ecosystem

128

the dataflow process. When an HDO relies on other entities to support data processing activities, the HDO should clearly communicate its data retention and privacy risk management needs to those entities. Implement program-specific privacy and security training and awareness activities.

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

Privacy and security may be compromised while performing business functions if employees do not understand how to incorporate security and privacy practices into their operational activities. Each organization that plays a role in healthcare RPM solutions must evaluate its role in the data ecosystem, the privacy and security risks that arise in the context of that role, and the training and awareness activities that will be most impactful for addressing those risks. Establish and communicate a process for patients to withdraw from the program. HDOs should work with their privacy program to consider in advance the privacy implications when patients decide to no longer participate in the RPM program and the processes that must occur to conclude their participation. For example, organizations will have data retention considerations for managing patient information collected as part of the program. HDOs should assure patients are aware that they have the ability to withdraw their consent prior to and during their participation in the program and that they have instructions for withdrawal. For example, HDOs may provide potential participants information regarding withdrawal from the program and who to contact with questions about that process in the telehealth informed consent documentation prior to their enrollment in the program. HDOs should consider an explicit consent model rather than an implicit consent. Patients may also directly request removal of their data from the RPM platform. HDOs will need to establish capabilities for decommissioning patients in the RPM solution as well as for communicating any related requirements to platform providers and other partners in the RPM solution.

Appendix E Benefits of IoT Device Cybersecurity Requirements The National Institute of Standards and Technology’s (NIST’s) Cybersecurity for the Internet of Things (IoT) program [38] supports development and application of standards, guidelines, and related tools to improve the cybersecurity of connected devices and the environments in which they are deployed. By collaborating with stakeholders across government, industry, international bodies, and academia, the program aims to cultivate trust and foster an environment that enables innovation on a global scale. Computing devices that integrate physical and/or sensing capabilities and network interface capabilities are being designed, developed, and deployed at an ever-increasing pace. These devices are fulfilling customer needs in all sectors of the economy. Many of these computing devices are connected to the internet. IoT devices combine network connectivity with the ability to sense or affect the physical world. Individuals may find challenges with applying privacy and cybersecurity controls as devices include greater functionality.

NIST SP 1800-30B: Securing Telehealth Remote Patient Monitoring Ecosystem

129

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

NIST’s Cybersecurity for IoT program has defined a baseline set of device cybersecurity capabilities that manufacturers should consider integrating into their IoT devices and that consumers should consider enabling/configuring in those devices. Device cybersecurity capabilities are cybersecurity features or functions that IoT devices provide through their own technical means (i.e., device hardware and software). Nontechnical supporting capabilities are actions that a manufacturer or third-party organization performs in support of the cybersecurity of an IoT device. Examples of nontechnical support include providing information about software updates, instructions for configuration settings, and supply chain information. Used together, device cybersecurity capabilities and nontechnical supporting capabilities can help mitigate cybersecurity risks related to the use of IoT devices while assisting customers in achieving their goals. Device cybersecurity capabilities and nontechnical supporting capabilities—if properly defined and integrated into the RPM devices and RPM architectural environment—can assist in securely deploying and configuring an RPM ecosystem.

E-1 Device Capabilities Mapping Table E-1 below builds on the Security Control Map in Section 3.5 of this document. The table lists both device cybersecurity capabilities and nontechnical supporting capabilities that map to NIST Cybersecurity Framework Subcategories that were considered relevant to RPM ecosystem risks. Selecting devices and/or third parties that provide these capabilities can support the secure deployment and configuration of the RPM ecosystem. The column listing mapping from Cybersecurity Framework Subcategories to the Health Insurance Portability and Accountability Act (HIPAA) Security Rule is included as an important sector-specific standard. Note: In the table below, the HIPAA Security Rule elements listed in the last column were previously mapped to the Cybersecurity Framework Subcategories. The device cybersecurity capabilities and nontechnical supporting capabilities listed were mapped to the Cybersecurity Framework Subcategories, not to the HIPAA Security Rule elements. In this sense, the Cybersecurity Framework Subcategories served as the central element joining the device cybersecurity capabilities and nontechnical supporting capabilities with the HIPAA Security Rule elements.

NIST SP 1800-30B: Securing Telehealth Remote Patient Monitoring Ecosystem

130

Table E-1 Mapping of Device Cybersecurity Capabilities and Nontechnical Supporting Capabilities to NIST Cybersecurity Framework Subcategories of the RPM Project This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

Cybersecurity Framework v1.1 Subcategory ID.AM-1: Physical devices and systems within the organization are inventoried.

Device Cybersecurity Capabilities

Ability to detect unauthorized hardware and software components.

Manufacturer Nontechnical Supporting Capabilities 

ID.AM-2: Software platforms and applications within the organization are inventoried.

ID.AM-4: External information systems are catalogued.

N/A

Ability to identify software loaded on the IoT device based on IoT device identity. Ability to detect unauthorized hardware and software components.

NIST SP 1800-30B: Securing Telehealth Remote Patient Monitoring Ecosystem

Providing details for how to establish unique identification for each IoT device associated with the system and critical system components within which it is used. Providing IoT device customers with the details necessary to establish and implement unique identification for each IoT device associated with the system and critical system components within which it is used. Providing IoT device customers with the details necessary to require unique identifiers for each IoT device associated with the system and critical system components within which it is used.

N/A

HIPAA Security Rule Mapping to Cybersecurity Framework Subcategory 45 C.F.R. §§ 164.308(a)(1)(ii)(A) 164.308(a)(4)(ii)(A) 164.308(a)(7)(ii)(E) 164.308(b) 164.310(d) 164.310(d)(2)(iii)

45 C.F.R. §§ 164.308(a)(1)(ii)(A) 164.308(a)(7)(ii)(E) Providing documentation detailing all the cloud services used to support the IoT device.

45 C.F.R. §§ 164.308(a)(4)(ii)(A) 164.308(b)

131

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

Cybersecurity Framework v1.1 Subcategory

Device Cybersecurity Capabilities

Manufacturer Nontechnical Supporting Capabilities 

ID.AM-5: Resources (e.g., hardware, devices, data, time, personnel, and software) are prioritized based on their classification, criticality, and business value.

N/A

N/A

ID.RA-1: Asset vulnerabilities are identified and documented.

N/A

NIST SP 1800-30B: Securing Telehealth Remote Patient Monitoring Ecosystem

Providing a detailed description of all logical interfaces to the IoT device and documenting the interfaces used by the manufacturer's third parties, and the purposes for such uses.

HIPAA Security Rule Mapping to Cybersecurity Framework Subcategory 164.314(a)(1) 164.314(a)(2)(i)(B) 164.314(a)(2)(ii) 164.316(b)(2) 45 C.F.R. §§ 164.308(a)(7)(ii)(E)

Providing details for performing the tests necessary for IoT device and related system software updates, for effectiveness and to identify potential side effects, before installation. Providing communications describing the types of security and privacy tests necessary for the IoT device and software before installation. Providing training and awareness information to IoT device customers that describe newly identified vulnerabilities and

45 C.F.R. §§ 164.308(a)(1)(ii)(A) 164.308(a)(4)(ii)(A) 164.308(a)(7)(ii)(E) 164.308(b) 164.310(d) 164.310(d)(2)(iii)

132

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

Cybersecurity Framework v1.1 Subcategory

ID.RA-4: Potential business impacts and likelihoods are identified.

Device Cybersecurity Capabilities

Manufacturer Nontechnical Supporting Capabilities

N/A

ID.RA-5: Threats, vulnerabilities, likelihoods, and impacts are used to determine risk.

N/A

ID.RA-6: Risk responses are identified and prioritized.

Ability to differentiate between when a device will likely operate as expected from when it may be in a degraded cybersecurity state.

NIST SP 1800-30B: Securing Telehealth Remote Patient Monitoring Ecosystem

threats (such as zero-day malware) for the associated IoT device. Providing the details necessary for the installation of IoT devices and associated systems security-relevant software updates within an organizationally defined time period from the vendor release of the updates. Providing education describing the operational impacts of the anti-malware activities on mission critical processes in the system where the IoT device is used. Providing education explaining the responsibilities of IoT device customers to perform their own risk assessments, using information provided by the manufacturer, to determine the risks the IoT device will bring into the IoT device customer’s systems. Providing the details necessary for the installation of IoT devices and associated systems security-relevant software updates within an organizationally defined time period from the vendor release of the updates.

HIPAA Security Rule Mapping to Cybersecurity Framework Subcategory

45 C.F.R. §§ 164.308(a)(1)(i) 164.308(a)(1)(ii)(A) 164.308(a)(1)(ii)(B) 164.308(a)(6) 164.308(a)(7)(ii)(E) 164.308(a)(8)

45 C.F.R. §§ 164.308(a)(1)(ii)(A) 164.308(a)(1)(ii)(B) 164.308(a)(1)(ii)(D) 164.308(a)(7)(ii)(D) 164.308(a)(7)(ii)(E) 164.316(a) 45 C.F.R. §§ 164.308(a)(1)(ii)(B) 164.314(a)(2)(i)(C) 164.314(b)(2)(iv)

133

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

Cybersecurity Framework v1.1 Subcategory PR.AC-1: Identities and credentials are issued, managed, verified, revoked, and audited for authorized devices, users and processes.

Device Cybersecurity Capabilities

  

  

  

Ability to uniquely identify the IoT device logically. Ability to uniquely identify a remote IoT device. Ability for the device to support a unique device ID (e.g., to allow it to be linked to the person or process assigned to use the IoT device). Ability to configure IoT device access control policies using IoT device identity. Ability to verify the identity of an IoT device. Ability to add a unique physical identifier at an external or internal location on the device authorized entities can access. Ability for the IoT device to hide or mask authentication information during authentication process. Ability to set and change authentication configurations, policies and limitations settings for the IoT device. Ability to revoke access to the device. Ability to create unique IoT device user accounts. Ability to identify unique IoT device user accounts.

NIST SP 1800-30B: Securing Telehealth Remote Patient Monitoring Ecosystem

Manufacturer Nontechnical Supporting Capabilities 

Providing details for how to establish unique identification for each IoT device associated with the system and critical system components within which it is used. Providing communications and documentation detailing how to perform account management activities, using the technical IoT device capabilities, or through supporting systems and/or tools. Providing the details necessary to establish and implement unique identification for each IoT device associated with the system and critical system components within which it is used. Providing the details necessary to require unique identifiers for each IoT device associated with the system and critical system components within which it is used. Providing education explaining how to establish and enforce approved authorizations for logical access to IoT device information and system resources. Providing education explaining how to control access to IoT devices implemented within IoT device customer information systems.

HIPAA Security Rule Mapping to Cybersecurity Framework Subcategory 45 C.F.R. §§ 164.308(a)(3)(ii)(B) 164.308(a)(3)(ii)(C) 164.308(a)(4)(i) 164.308(a)(4)(ii)(B) 164.308(a)(4)(ii)(C ) 164.312(a)(2)(i)

134

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

Cybersecurity Framework v1.1 Subcategory

Device Cybersecurity Capabilities

  

Ability to create organizationally defined accounts that support privileged roles with automated expiration conditions. Ability to establish organizationally defined user actions for accessing the IoT device and/or device interface. Ability to enable automation and reporting of account management activities. o Ability to assign access to IoT device audit controls to specific roles or organizationally defined personnel. o Ability to control access to IoT device audit data. o Ability to identify the user, process or device requesting access to the audit/accountability information (i.e., to ensure only authorized users and/or devices have access). Ability to establish conditions for shared/group accounts on the IoT device. Ability to administer conditions for shared/group accounts on the IoT device. Ability to restrict the use of shared/group accounts on the IoT device according to organizationally defined conditions.

NIST SP 1800-30B: Securing Telehealth Remote Patient Monitoring Ecosystem

Manufacturer Nontechnical Supporting Capabilities 

HIPAA Security Rule Mapping to Cybersecurity Framework Subcategory

Providing education explaining how to enforce authorized access at the system level.

135

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

Cybersecurity Framework v1.1 Subcategory PR.AC-2: Physical access to assets is managed and protected.

Device Cybersecurity Capabilities

Manufacturer Nontechnical Supporting Capabilities

N/A

PR.AC-3: Remote access is managed.

Ability to configure IoT device access control policies using IoT device identity. o Ability to hide IoT device identity from non-authorized entities. o Ability for the IoT device to differentiate between authorized and unauthorized remote users.

NIST SP 1800-30B: Securing Telehealth Remote Patient Monitoring Ecosystem

N/A

Providing descriptions of the types of physical access practices, and manufacturer suggested hardware or other types of devices, that can be used to prevent unauthorized physical access to the IoT device based upon the determined risk level that the device brings to the IoT customer’s system. Providing descriptions of the physical access security procedures the manufacturer recommends for limiting physical access to the device and to associated device controls. Providing details of indications, and recommendations for how to determine, when unauthorized physical access to the IoT device was or is attempted or is occurring.

HIPAA Security Rule Mapping to Cybersecurity Framework Subcategory 45 C.F.R. §§ 164.308(a)(1)(ii)(B) 164.308(a)(7)(i) 164.308(a)(7)(ii)(A) 164.310(a)(1) 164.310(a)(2)(i) 164.310(a)(2)(ii)

45 C.F.R. §§ 164.308(a)(4)(i) 164.308(b)(1) 164.308(b)(3) 164.310(b) 164.312(e)(1) 164.312(e)(2)(ii)

136

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

Cybersecurity Framework v1.1 Subcategory

Device Cybersecurity Capabilities

Manufacturer Nontechnical Supporting Capabilities

HIPAA Security Rule Mapping to Cybersecurity Framework Subcategory

Ability for the IoT device to differentiate between authorized and unauthorized physical device users. Ability to authenticate external users and systems. Ability to securely interact with authorized external, third-party systems. Ability to identify when an external system meets the required security requirements for a connection. Ability to establish secure communications with internal systems when the device is operating on external networks. Ability to establish requirements for remote access to the IoT device and/or IoT device interface, including: o usage restrictions o configuration requirements o connection requirements o manufacturer established requirement Ability to enforce the established local and remote access requirements. Ability to prevent external access to the IoT device management interface. o

  

 

NIST SP 1800-30B: Securing Telehealth Remote Patient Monitoring Ecosystem

137

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

Cybersecurity Framework v1.1 Subcategory

Device Cybersecurity Capabilities

  

PR.AC-4: Access permissions and authorizations are managed, incorporating the principles of least privilege and separation of duties.

  

 

Ability to control the IoT device’s logical interface (e.g., locally or remotely). Ability to detect remote activation attempts. Ability to detect remote activation of a collaborative computing device/component (e.g., microphone, camera). Ability to detect remote activation of sensors. Ability to revoke access to the device. Ability to establish access to the IoT device to perform organizationally defined user actions without identification or authentication. Ability to assign roles to IoT device user accounts. Ability to support a hierarchy of logical access privileges for the IoT device based on roles (e.g., admin, emergency, user, local, temporary) o Ability to establish user accounts to support role-based logical access privileges. o Ability to administer user accounts to support role-based logical access privileges. o Ability to use organizationally defined roles to define each user account’s access and permitted device actions.

NIST SP 1800-30B: Securing Telehealth Remote Patient Monitoring Ecosystem

Manufacturer Nontechnical Supporting Capabilities

Providing the tools, assistance, instructions, and other types of information to support establishing a hierarchy of role-based privileges within the IoT device. Providing details about the specific types of manufacturer’s needs to access the IoT device interfaces; such as for specific support, updates, ongoing maintenance, and other purposes. Providing documentation with instructions for the IoT device customer to follow for how to restrict interface connections that enable specific activities. Providing descriptions of the types of access to the IoT device that the manufacturer will require on an ongoing or regular basis. Providing detailed instructions for how to implement management and operational

HIPAA Security Rule Mapping to Cybersecurity Framework Subcategory

45 C.F.R. §§ 164.308(a)(3) 164.308(a)(4) 164.310(a)(2)(iii) 164.310(b) 164.312(a)(1) 164.312(a)(2)(i)

138

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

Cybersecurity Framework v1.1 Subcategory

Device Cybersecurity Capabilities

Ability to support multiple levels of user/process account functionality and roles for the IoT device. Ability to apply least privilege to user accounts (i.e., to ensure that the processes operate at privilege levels no higher than necessary to accomplish required functions) o Ability to create additional processes, roles (e.g., admin, emergency, temporary) and accounts as necessary to achieve least privilege. o Ability to apply least privilege settings within the device (i.e., to ensure that the processes operate at privilege levels no higher than necessary to accomplish required functions). o Ability to limit access to privileged device settings that are used to establish and administer authorization requirements. o Ability for authorized users to access privileged settings. Ability to create organizationally defined accounts that support privileged roles with automated expiration conditions.

Manufacturer Nontechnical Supporting Capabilities

o

NIST SP 1800-30B: Securing Telehealth Remote Patient Monitoring Ecosystem

HIPAA Security Rule Mapping to Cybersecurity Framework Subcategory

controls based on the role of the IoT device user, and not on an individual basis. Providing documentation and/or other communications describing how to implement management and operational controls to protect data obtained from IoT devices and associated systems from unauthorized access, modification, and deletion. Providing a detailed description of the other types of devices and systems that will access the IoT device during customer use of the device, and how they will access it. Providing communications and detailed instructions for implementing a hierarchy of privilege levels to use with the IoT device and/or necessary associated information systems. Providing communications and documentation detailing how to perform account management activities, using the technical IoT device capabilities, or through supporting systems and/or tools. Providing education explaining how to establish and enforce approved

139

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

Cybersecurity Framework v1.1 Subcategory

Device Cybersecurity Capabilities

  

Ability to establish organizationally defined user actions for accessing the IoT device and/or device interface. Ability to enable automation and reporting of account management activities. o Ability to assign access to IoT device audit controls to specific roles or organizationally defined personnel. o Ability to control access to IoT device audit data. o Ability to identify the user, process or device requesting access to the audit/accountability information (i.e., to ensure only authorized users and/or devices have access). Ability to establish conditions for shared/group accounts on the IoT device. Ability to administer conditions for shared/group accounts on the IoT device. Ability to restrict the use of shared/group accounts on the IoT device according to organizationally defined conditions. Ability to implement dynamic access control approaches (e.g., service-oriented architectures) that rely on:

NIST SP 1800-30B: Securing Telehealth Remote Patient Monitoring Ecosystem

Manufacturer Nontechnical Supporting Capabilities

HIPAA Security Rule Mapping to Cybersecurity Framework Subcategory

authorizations for logical access to IoT device information and system resources. Providing education explaining how to control access to IoT devices implemented within IoT device customer information systems. Providing education explaining how to enforce authorized access at the system level. Providing education and supporting materials explaining how to establish roles and responsibilities for IoT device data security, using the device capabilities and/or other services that communicate or interface with the device. Providing education and supporting materials describing the IoT device capabilities for role-based controls, and how to establish different roles within the IoT device. Providing education and supporting materials for how to establish roles to support IoT device policies, procedures and associated documentation.

140

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

Cybersecurity Framework v1.1 Subcategory

Device Cybersecurity Capabilities

Manufacturer Nontechnical Supporting Capabilities

HIPAA Security Rule Mapping to Cybersecurity Framework Subcategory

run-time access control decisions facilitated by dynamic privilege management. o organizationally defined actions to access/use device Ability to allow information sharing capabilities based upon the type and/or role of user attempting to share the information. Ability to restrict access to IoT device software, hardware, and data based on user account roles, used with proper authentication of the identity of the user to determine type of authorization. Ability to establish pre-defined restrictions for information searches within the device. Ability to establish limits on authorized concurrent device sessions for: o user accounts o roles o groups o dates o times o locations o manufacturer-established parameters Ability to restrict updating actions to authorized entities. o

 

NIST SP 1800-30B: Securing Telehealth Remote Patient Monitoring Ecosystem

141

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

Cybersecurity Framework v1.1 Subcategory

Device Cybersecurity Capabilities

  

    PR.AC-5: Network integrity is protected (e.g., network segregation, network segmentation).

N/A

PR.AC-6: Identities are proofed and bound to credentials and asserted in interactions.

 

Manufacturer Nontechnical Supporting Capabilities

HIPAA Security Rule Mapping to Cybersecurity Framework Subcategory

Ability to restrict access to the cybersecurity state indicator to authorized entities. Ability to enforce the established local and remote access requirements. Ability to update the device’s software through remote (e.g., network download) and/or local (e.g., removable media) means. Ability to store and process session identifiers. Ability to identify and track sessions with identifiers. Ability to enforce access to memory space through the kernel. Ability to prevent a process from accessing memory space of another process. N/A

Ability to obtain and validate certificates. Ability to identify unique users interacting with the device (to allow for user session monitoring).

NIST SP 1800-30B: Securing Telehealth Remote Patient Monitoring Ecosystem

45 C.F.R. §§ 164.308(a)(4)(ii)(B) 164.310(a)(1) 164.310(b) 164.312(a)(1) 164.312(b) 164.312(c)

N/A

142

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

Cybersecurity Framework v1.1 Subcategory PR.AC-7: Users, devices, and other assets are authenticated (e.g., single-factor, multifactor) commensurate with the risk of the transaction (e.g., individuals’ security and privacy risks and other organizational risks).

Device Cybersecurity Capabilities

 

Ability to configure IoT device access control policies using IoT device identity. o Ability to hide IoT device identity from non-authorized entities. o Ability for the IoT device to differentiate between authorized and unauthorized remote users. o Ability for the IoT device to differentiate between authorized and unauthorized physical device users. Ability for the IoT device to identify itself as an authorized entity to other devices. Ability for the IoT device to require authentication prior to connecting to the device. Ability for the IoT device to support a second, or more, authentication method(s) through an out-of-band path such as: o temporary passwords or other oneuse log-on credentials o third-party credential checks o biometrics o text messages o hard tokens o manufacturer proprietary method

NIST SP 1800-30B: Securing Telehealth Remote Patient Monitoring Ecosystem

Manufacturer Nontechnical Supporting Capabilities 

HIPAA Security Rule Mapping to Cybersecurity Framework Subcategory

Providing detailed instructions and guidance for establishing activities performed by the IoT device that do not require identification or authentication. Providing documentation describing the specific IoT platforms used with the device to support required IoT authentication control techniques. Providing documentation with details describing external authentication by IoT platforms and associated authentication methods that can be used with the IoT device.

143

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

Cybersecurity Framework v1.1 Subcategory

Device Cybersecurity Capabilities

 

Manufacturer Nontechnical Supporting Capabilities

HIPAA Security Rule Mapping to Cybersecurity Framework Subcategory

Ability to set the time period for how long the device will remain locked after an established configurable limit of unsuccessful login attempts has been met. Ability to disable or lock access to the device after an established number of unsuccessful login attempts. Ability to display and/or report the previous date and time of the last successful login authentication. Ability to automatically disable accounts for the IoT device after an established period of inactivity. o Ability to support automatic logout of inactive accounts after a configurable established time period. o Ability to support automatic removal of temporary, emergency and other special use accounts after an established time period. Ability to authenticate external users and systems. Ability to display to IoT device users an organizationally defined system use notification message or banner prior to successful IoT device authentication.

NIST SP 1800-30B: Securing Telehealth Remote Patient Monitoring Ecosystem

144

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

Cybersecurity Framework v1.1 Subcategory

Device Cybersecurity Capabilities

  

Manufacturer Nontechnical Supporting Capabilities

HIPAA Security Rule Mapping to Cybersecurity Framework Subcategory

Ability to create an organizationally defined system use notification message or banner to be displayed on the IoT device. o Ability to edit an existing IoT device display. o Ability to establish the maximum size (e.g., in characters, bytes) of the available device display. Ability to keep the notification message or banner on the device screen until the device user actively acknowledges and agrees to the usage conditions. Ability to identify authorized users and processes. Ability to differentiate between authorized and unauthorized users (physical and remote). Ability to create organizationally defined accounts that support privileged roles with automated expiration conditions. Ability to establish organizationally defined user actions for accessing the IoT device and/or device interface. Ability to enable automation and reporting of account management activities.

NIST SP 1800-30B: Securing Telehealth Remote Patient Monitoring Ecosystem

145

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

Cybersecurity Framework v1.1 Subcategory

Device Cybersecurity Capabilities

Manufacturer Nontechnical Supporting Capabilities

HIPAA Security Rule Mapping to Cybersecurity Framework Subcategory

Ability to assign access to IoT device audit controls to specific roles or organizationally defined personnel. o Ability to control access to IoT device audit data. o Ability to identify the user, process or device requesting access to the audit/accountability information (i.e., to ensure only authorized users and/or devices have access). Ability to establish conditions for shared/group accounts on the IoT device. Ability to administer conditions for shared/group accounts on the IoT device. Ability to restrict the use of shared/group accounts on the IoT device according to organizationally defined conditions. Ability to restrict access to IoT device software, hardware, and data based on user account roles, used with proper authentication of the identity of the user to determine type of authorization. Ability to establish secure communications with internal systems when the device is operating on external networks. o

  

NIST SP 1800-30B: Securing Telehealth Remote Patient Monitoring Ecosystem

146

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

Cybersecurity Framework v1.1 Subcategory

Device Cybersecurity Capabilities

 PR.DS-1: Data-at-rest is protected.

      

   

Ability to verify and authenticate any update before installing it. Ability to execute cryptographic mechanisms of appropriate strength and performance. Ability to obtain and validate certificates. Ability to perform authenticated encryption algorithms. Ability to change keys securely. Ability to generate key pairs. Ability to store encryption keys securely. Ability to cryptographically store passwords at rest, as well as device identity and other authentication data. Ability to support data encryption and signing to prevent data from being altered in device storage. Ability to secure data stored locally on the device. Ability to secure data stored in remote storage areas (e.g., cloud, server). Ability to utilize separate storage partitions for system and user data. Ability to protect the audit information through: o encryption o digitally signing audit files

NIST SP 1800-30B: Securing Telehealth Remote Patient Monitoring Ecosystem

Manufacturer Nontechnical Supporting Capabilities

Providing detailed instructions for how to implement management and operational controls for securely handling and retaining IoT device data, associated systems data, and data output from the IoT device. Providing education describing how to securely handle and retain IoT device data, associated systems data, and data output from the IoT device to meet requirements of the IoT device customers’ organizational security policies, contractual requirements, applicable Federal laws, Executive Orders, directives, policies, regulations, standards, and other legal requirements.

HIPAA Security Rule Mapping to Cybersecurity Framework Subcategory

45 C.F.R. §§ 164.308(a)(1)(ii)(D) 164.308(b)(1) 164.310(d) 164.312(a)(1) 164.312(a)(2)(iii) 164.312(a)(2)(iv)

147

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

Cybersecurity Framework v1.1 Subcategory

Device Cybersecurity Capabilities

securely sending audit files to another device o other protections created by the device manufacturer Ability to execute cryptographic mechanisms of appropriate strength and performance. Ability to perform authenticated encryption algorithms. Ability to change keys securely. Ability to store encryption keys securely. Ability to secure data stored in remote storage areas (e.g., cloud, server). Ability to support trusted data exchange with a specified minimum-strength cryptography algorithm. Ability to support data encryption and signing to prevent data from being altered in transit. Ability to utilize one or more capabilities to protect transmitted data from unauthorized access and modification. Ability to use cryptographic means to validate the integrity of data transmitted. Ability to protect the audit information through: o encryption o digitally signing audit files

Manufacturer Nontechnical Supporting Capabilities

HIPAA Security Rule Mapping to Cybersecurity Framework Subcategory

o

PR.DS-2: Data-intransit is protected.

     

 

 

NIST SP 1800-30B: Securing Telehealth Remote Patient Monitoring Ecosystem

Providing documentation and/or other communications describing how to implement management and operational controls to protect data obtained from IoT devices and associated systems from unauthorized access, modification, and deletion. Providing education describing how to securely handle and retain IoT device data, associated systems data, and data output from the IoT device to meet requirements of the IoT device customers’ organizational security policies, contractual requirements, applicable Federal laws, Executive Orders, directives, policies, regulations, standards, and other legal requirements.

45 C.F.R. §§ 164.308(b)(1) 164.308(b)(2) 164.312(e)(1) 164.312(e)(2)(i) 164.312(e)(2)(ii) 164.314(b)(2)(i)

148

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

Cybersecurity Framework v1.1 Subcategory

Device Cybersecurity Capabilities

o o PR.DS-3: Assets are formally managed throughout removal, transfers, and disposition.

N/A

PR.DS-4: Adequate capacity to ensure availability is maintained.

 

PR.DS-5: Protections against data leaks are implemented.

PR.DS-6: Integrity checking

Manufacturer Nontechnical Supporting Capabilities

HIPAA Security Rule Mapping to Cybersecurity Framework Subcategory

securely sending audit files to another device other protections created by the device manufacturer N/A

45 C.F.R. §§ 164.308(a)(1)(ii)(A) 164.310(a)(2)(ii) 164.310(a)(2)(iii) 164.310(a)(2)(iv) 164.310(d)(1) 164.310(d)(2)

Ability to enforce configured disk quotas. Ability to provide sufficient resources to store and run the operating environment (e.g., operating systems, firmware, applications). Ability to utilize file compression technologies (e.g., to protect against denial of service).

N/A

45 C.F.R. §§ 164.308(a)(1)(ii)(A) 164.308(a)(1)(ii)(B) 164.308(a)(7) 164.310(a)(2)(i) 164.310(d)(2)(iv) 164.312(a)(2)(ii)

Ability to control device responses to device input. Ability to control output from the device.

N/A

45 C.F.R. §§ 164.308(a)(1)(ii)(D) 164.308(a)(3) 164.308(a)(4) 164.310(b) 164.310(c) 164.312(a)

Ability to identify software loaded on the IoT device based on IoT device identity.

NIST SP 1800-30B: Securing Telehealth Remote Patient Monitoring Ecosystem

Providing documentation and/or other communications describing how to

45 C.F.R. §§ 164.308(a)(1)(ii)(D)

149

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

Cybersecurity Framework v1.1 Subcategory mechanisms are used to verify software, firmware, and information integrity.

Device Cybersecurity Capabilities

    

 

 

Ability to verify digital signatures. Ability to run hashing algorithms. Ability to perform authenticated encryption algorithms. Ability to compute and compare hashes. Ability to utilize one or more capabilities to protect transmitted data from unauthorized access and modification. Ability to use cryptographic means to validate the integrity of data transmitted. Ability to verify software updates come from valid sources by using an effective method (e.g., digital signatures, checksums, certificate validation). Ability to verify and authenticate any update before installing it. Ability to store the operating environment (e.g., firmware image, software, applications) in read-only media (e.g., Read Only Memory).

Manufacturer Nontechnical Supporting Capabilities

NIST SP 1800-30B: Securing Telehealth Remote Patient Monitoring Ecosystem

implement management and operational controls to protect data obtained from IoT devices and associated systems from unauthorized access, modification, and deletion. Providing communications to IoT device customers describing how to implement management and operational controls to protect IoT device data integrity and associated systems data integrity. Providing IoT device customers with the details necessary to support secure implementation of the IoT device and associated systems data integrity controls. Providing IoT device customers with documentation describing the data integrity controls built into the IoT device and how to use them. If there are no data integrity controls built into the IoT device, include documentation explaining to IoT device customers the ways to achieve IoT device data integrity. Providing details for how to review and update the IoT device and associated systems while preserving data integrity.

HIPAA Security Rule Mapping to Cybersecurity Framework Subcategory 164.312(b) 164.312(c)(1) 164.312(c)(2) 164.312(e)(2)(i)

150

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

Cybersecurity Framework v1.1 Subcategory PR.IP-4: Backups of information are conducted, maintained, and tested.

Device Cybersecurity Capabilities

Manufacturer Nontechnical Supporting Capabilities

N/A

PR.IP-6: Data is destroyed according to policy.

Ability to sanitize or purge specific or all data in the device.

 

NIST SP 1800-30B: Securing Telehealth Remote Patient Monitoring Ecosystem

Providing education to IoT device customers covering the instructions and details necessary for them to create accurate backups and to recover the backups when necessary. Providing education to IoT device customers that includes instructions describing how to back up data from systems where IoT device data is stored. Providing awareness reminders and tips to IoT device customers (e.g., directly in person, in videos, in an online webinar) for various aspects involved with backing up the IoT device data. Providing documentation describing how to irreversibly delete data from the IoT device. Providing IoT device customers the details necessary for them to know when and how to remove all data from IoT devices prior to removing the devices from facilities for offsite maintenance or repairs. Providing information describing how to use the IoT device capabilities to remove all data from the device. Providing education that explains and/or demonstrates how to securely and

HIPAA Security Rule Mapping to Cybersecurity Framework Subcategory 164.308(a)(7)(ii)(A) 164.308(a)(7)(ii)(B) 164.308(a)(7)(ii)(D) 164.310(a)(2)(i) 164.310(d)(2)(iv)

45 C.F.R. §§ 164.310(d)(2)(i) 164.310(d)(2)(ii)

151

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

Cybersecurity Framework v1.1 Subcategory

Device Cybersecurity Capabilities

Manufacturer Nontechnical Supporting Capabilities

HIPAA Security Rule Mapping to Cybersecurity Framework Subcategory

irreversibly delete data from the IoT device and any associated data storage locations.

PR.IP-9: Response plans (Incident Response and Business Continuity) and recovery plans (Incident Recovery and Disaster Recovery) are in place and managed.

N/A

N/A

PR.IP-10: Response and recovery plans are tested.

N/A

N/A

PR.IP-12: A vulnerability management plan is developed and implemented.

N/A

Providing communications and documentation detailing the manufacturer’s recommended vulnerability and patch management plan.

45 C.F.R. §§ 164.308(a)(1)(i) 164.308(a)(1)(ii)(A) 164.308(a)(1)(ii)(B)

PR.MA-1: Maintenance and repair of organizational assets are performed and logged, with

N/A

Providing details about the types of, and situations that trigger, local and/or remote maintenance activities required once the device is purchased and deployed in the organization’s digital ecosystem or within an individual consumer’s home.

45 C.F.R. §§ 164.308(a)(3)(ii)(A) 164.310(a)(2)(iv)

NIST SP 1800-30B: Securing Telehealth Remote Patient Monitoring Ecosystem

45 C.F.R. §§ 164.308(a)(6) 164.308(a)(6)(i) 164.308(a)(7) 164.310(a)(2)(i) 164.312(a)(2)(ii)

45 C.F.R. §§ 164.308(a)(7)(ii)(D)

152

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

Cybersecurity Framework v1.1 Subcategory

Device Cybersecurity Capabilities

approved and controlled tools.

Manufacturer Nontechnical Supporting Capabilities 

NIST SP 1800-30B: Securing Telehealth Remote Patient Monitoring Ecosystem

HIPAA Security Rule Mapping to Cybersecurity Framework Subcategory

Providing instructions and documentation describing the physical and logical access capabilities necessary to the IoT device to perform each type of maintenance activity. Providing other information and actions as necessary for physically securing, and securely using, the IoT device based upon the IoT device use, purpose, and other contextual factors related to the digital ecosystem(s) within which they are intended to be used. Providing the details necessary for IoT device customers to implement only organizationally approved IoT device diagnostic tools within their system. Providing detailed documentation describing the tools manufacturers require for IoT device diagnostics activities. Providing the details and instructions to perform necessary IoT device maintenance activities and repairs. Providing communications and comprehensive documentation describing the IoT device maintenance operations performed by the manufacturer and the manufacturer’s supporting entities.

153

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

Cybersecurity Framework v1.1 Subcategory

Device Cybersecurity Capabilities

Manufacturer Nontechnical Supporting Capabilities 

NIST SP 1800-30B: Securing Telehealth Remote Patient Monitoring Ecosystem

HIPAA Security Rule Mapping to Cybersecurity Framework Subcategory

Providing communications and comprehensive documentation describing maintenance operations that the IoT device customer is required to perform. If such comprehensive IoT device maintenance operations documentation does not exist, the manufacturer should clearly communicate to IoT device customers that the user must perform these operations themselves. Providing communications that include details for the recommended events that will trigger IoT device system reviews and/or maintenance by the manufacturer. Providing communications and documentation detailing how to perform recommended local and/or remote maintenance activities. Providing the details necessary to enable IoT device customers to monitor onsite and offsite IoT device maintenance activities. Providing the details necessary to implement management and operational controls for IoT device maintenance personnel and associated authorizations,

154

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

Cybersecurity Framework v1.1 Subcategory

Device Cybersecurity Capabilities

Manufacturer Nontechnical Supporting Capabilities

NIST SP 1800-30B: Securing Telehealth Remote Patient Monitoring Ecosystem

HIPAA Security Rule Mapping to Cybersecurity Framework Subcategory

and record-keeping of maintenance organizations and personnel. Providing communications describing the type and nature of the local and/or remote maintenance activities that will involve and require manufacturer personnel, or their contractors, once the device is purchased and deployed in the IoT device customer’s organization. Providing IoT device customers with the details necessary to implement management and operational controls in support of their security policies and legal requirements for IoT device maintenance for assigned organizationally defined personnel or roles to follow. Providing documented descriptions of the specific maintenance procedures for defined maintenance tasks. Providing the details necessary for customers to document attempts to obtain IoT device components or IoT device information system service documentation when such documentation is either unavailable or nonexistent, and documenting the appropriate response for

155

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

Cybersecurity Framework v1.1 Subcategory

Device Cybersecurity Capabilities

Manufacturer Nontechnical Supporting Capabilities

 

NIST SP 1800-30B: Securing Telehealth Remote Patient Monitoring Ecosystem

HIPAA Security Rule Mapping to Cybersecurity Framework Subcategory

manufacturer employees, or supporting entities, to follow. Following procedures to obtain input from IoT device customers about the breadth and depth of the technical documentation provided with the IoT device to determine if it is acceptable to support customer needs. Providing a process for IoT device customers to contact the manufacturer to ask questions or obtain help related to the IoT device configuration settings. Providing information to allow for in-house support from within the IoT device customer organization. Providing education explaining how to inspect IoT device and/or use maintenance tools to ensure the latest software updates and patches are installed. Providing education for how to scan for critical software updates and patches. Providing education that explains the legal requirements governing IoT device maintenance responsibilities or how to meet specific types of legal requirements when using the IoT device.

156

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

Cybersecurity Framework v1.1 Subcategory PR.MA-2: Remote maintenance of organizational assets is approved, logged, and performed in a manner that prevents unauthorized access.

Device Cybersecurity Capabilities

Manufacturer Nontechnical Supporting Capabilities

N/A

NIST SP 1800-30B: Securing Telehealth Remote Patient Monitoring Ecosystem

Providing details about the types of, and situations that trigger, local and/or remote maintenance activities required once the device is purchased and deployed in the organization’s digital ecosystem or within an individual consumer’s home. Providing instructions and documentation describing the physical and logical access capabilities necessary to the IoT device to perform each type of maintenance activity. Providing other information and actions as necessary for physically securing, and securely using, the IoT device based upon the IoT device use, purpose, and other contextual factors related to the digital ecosystem(s) within which they are intended to be used. Providing the details and instructions to perform necessary IoT device maintenance activities and repairs. Providing communications and comprehensive documentation describing the IoT device maintenance operations performed by the manufacturer and the manufacturer’s supporting entities.

HIPAA Security Rule Mapping to Cybersecurity Framework Subcategory 45 C.F.R. §§ 164.308(a)(1)(ii)(D) 164.308(a)(3)(ii)(A) 164.310(d)(1) 164.310(d)(2)(ii) 164.310(d)(2)(iii) 164.312(a) 164.312(a)(2)(ii) 164.312(a)(2)(iv) 164.312(b) 164.312(d) 164.312(e)

157

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

Cybersecurity Framework v1.1 Subcategory

Device Cybersecurity Capabilities

Manufacturer Nontechnical Supporting Capabilities 

NIST SP 1800-30B: Securing Telehealth Remote Patient Monitoring Ecosystem

HIPAA Security Rule Mapping to Cybersecurity Framework Subcategory

Providing communications and documentation detailing how to perform recommended local and/or remote maintenance activities. Providing the details necessary to enable IoT device customers to monitor onsite and offsite IoT device maintenance activities. Providing the details necessary for maintaining records for nonlocal IoT device maintenance and diagnostic activities. Providing the details necessary to implement management and operational controls for IoT device maintenance personnel and associated authorizations, and record-keeping of maintenance organizations and personnel. Providing communications describing the type and nature of the local and/or remote maintenance activities that will involve and require manufacturer personnel, or their contractors, once the device is purchased and deployed in the IoT device customer’s organization. Providing IoT device customers with the details necessary to implement management and operational controls in

158

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

Cybersecurity Framework v1.1 Subcategory

Device Cybersecurity Capabilities

Manufacturer Nontechnical Supporting Capabilities

 PR.PT-1: Audit/log records are determined, documented, implemented, and reviewed in accordance with policy.

 

 

Ability to preserve system state information. Ability to support a list of events that are necessary for auditing purposes (to support the organizational auditing policy). Ability to identify and capture organizationally defined events using a persistent method. Ability to capture information from organizationally defined cybersecurity events (e.g., cybersecurity state, time) through organizationally defined means (e.g., logs). Ability to create audit logs within the device for organizationally defined and auditable events (e.g., account creation, modification, enabling, disabling, removal actions, notifications). Ability to track users interacting with the device, the time they interacted with the device, the time the user logged out of the

NIST SP 1800-30B: Securing Telehealth Remote Patient Monitoring Ecosystem

support of their security policies and legal requirements for IoT device maintenance for assigned organizationally defined personnel or roles to follow. Providing documented descriptions of the specific maintenance procedures for defined maintenance tasks. Providing the details requested by IoT device customers to perform periodic checks and/or audits to ensure IoT device security controls are functioning as intended following maintenance and repairs. Providing IoT device customers, upon their request, with the tools, assistance, instructions, and other support for the IoT device to perform audit and log maintenance and repairs.

HIPAA Security Rule Mapping to Cybersecurity Framework Subcategory

45 C.F.R. §§ 164.308(a)(1)(i) 164.308(a)(1)(ii)(D) 164.308(a)(5)(ii)(B) 164.308(a)(5)(ii)(C) 164.308(a)(2) 164.308(a)(3)(ii)(A)

159

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

Cybersecurity Framework v1.1 Subcategory

Device Cybersecurity Capabilities

Manufacturer Nontechnical Supporting Capabilities

HIPAA Security Rule Mapping to Cybersecurity Framework Subcategory

device, and to list this information in an audit log. Ability to log information pertaining to: o the type of event that occurred o the time that the event occurred o where the event occurred o the source of the event o the outcome of the event o the identity of users/processes associated with the event Ability to support auditing of configuration actions such as: o Current configuration state. o History of configuration changes. o When changes in configuration occurred. o Which account made the configuration change. Ability to provide information as to why the device captured a particular event or set of events. Ability to capture organizationally defined information to support examination of security incidents. Ability to record stored data access and usage.

NIST SP 1800-30B: Securing Telehealth Remote Patient Monitoring Ecosystem

160

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

Cybersecurity Framework v1.1 Subcategory

Device Cybersecurity Capabilities

  

 

Manufacturer Nontechnical Supporting Capabilities

HIPAA Security Rule Mapping to Cybersecurity Framework Subcategory

Ability to comply with organizational policy for storing persistent audit logs up to a predefined size. Ability to comply with organizational policy for audit log retention period. Ability to delete audit logs in accordance with organizational policy. Ability to send alerts when the logs are too big for the device to continue to store (if the predefined amount of time has not yet passed to delete them). Ability to support organizationally defined granularity in device timing measurements. Ability to use synchronization with a verified time source to determine the validity of a time stamp. Ability to record timestamps convertible to Coordinated Universal Time (UTC) or Greenwich Mean Time (GMT) to support a standardized representation of timing. Ability to log timing measurements outside a threshold value (e.g., enabling alerts if the device’s system time is not reliable). Ability to run audit scans (automated or otherwise) to provide specific information

NIST SP 1800-30B: Securing Telehealth Remote Patient Monitoring Ecosystem

161

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

Cybersecurity Framework v1.1 Subcategory

Device Cybersecurity Capabilities

 PR.PT-3: The principle of least functionality is incorporated by configuring systems to provide only essential capabilities.

 

     

(e.g., requested for an external process to audit the device). Ability to send requested audit logs to an external audit process or information system (e.g., where its auditing information can be checked to allow review, analysis, and reporting). Ability to keep an accurate internal system time. Ability to restrict use of IoT device components (e.g., ports, functions, microphones, video). Ability to logically or physically disable any local and network interfaces that are not necessary for the core functionality of the device. Ability to restrict use of IoT device services. Ability to execute code in confined virtual environments. Ability to separate IoT device processes into separate execution domains. Ability to separate the levels of IoT device user functionality. Ability to authorize various levels of IoT device functionality. Ability to restrict components/features of the IoT device (e.g., ports, functions, protocols,

NIST SP 1800-30B: Securing Telehealth Remote Patient Monitoring Ecosystem

Manufacturer Nontechnical Supporting Capabilities

N/A

HIPAA Security Rule Mapping to Cybersecurity Framework Subcategory

45 C.F.R. §§ 164.308(a)(3) 164.308(a)(4) 164.310(a)(2)(iii) 164.310(b) 164.310(c) 164.312(a)(1)

162

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

Cybersecurity Framework v1.1 Subcategory

PR.PT-4: Communications and control networks are protected.

Device Cybersecurity Capabilities

   

services) in accordance with organizationally defined policies. Ability to support wireless technologies needed by the organization (e.g., microwave, packet radio, ultrahigh frequency/very high frequency]), Bluetooth, manufacturer defined). Ability to support communications technologies (including but not limited to): o IEEE 802.11 o Bluetooth o Ethernet o Manufacturer defined Ability to establish and configure IoT device settings for wireless technologies, including authentication protocols (e.g., Extensible Authentication Protocol [EAP]/TLS, Protected Extensible Authentication Protocol [PEAP]). Ability to enforce traffic flow policies. Ability to utilize standardized protocols. Ability to establish network connections. Ability to terminate network connections (e.g., automatically based on organizationally defined parameters).

NIST SP 1800-30B: Securing Telehealth Remote Patient Monitoring Ecosystem

Manufacturer Nontechnical Supporting Capabilities

N/A

HIPAA Security Rule Mapping to Cybersecurity Framework Subcategory

45 C.F.R. §§ 164.308(a)(1)(ii)(D) 164.312(a)(1) 164.312(b) 164.312(e)

163

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

Cybersecurity Framework v1.1 Subcategory

Device Cybersecurity Capabilities

   DE.AE-1: A baseline of network operations and expected data flows for users and systems is established and managed.

N/A

DE.AE-2: Detected events are analyzed to understand attack targets and methods.

DE.CM-1: The network is

Manufacturer Nontechnical Supporting Capabilities

Ability to de-allocate Transmission Control Protocol/Internet Protocol (TCP/IP) address/port pairings. Ability to establish communications channels. Ability to secure the communications channels. Ability to interface with Domain Name System (DNS)/DNS Security Extensions (DNSSEC).

HIPAA Security Rule Mapping to Cybersecurity Framework Subcategory

Providing documentation describing how to implement and securely deploy monitoring devices and tools for IoT devices and associated systems.

45 C.F.R. §§ 164.308(a)(1)(ii)(D) 164.312(b)

Ability to identify organizationally defined cybersecurity events (e.g., expected state change) that may occur on or involving the IoT device.

Providing documentation describing IoT device behavior indicators that could occur when an attack is being launched.

45 C.F.R. §§ 164.308(a)(1)(i) 164.308(a)(1)(ii)(D) 164.308(a)(5)(ii)(B) 164.308(a)(5)(ii)(C) 164.308(6)(i) 164.308(a)(6)(i)

Ability to monitor specific actions based on the IoT device identity.

Providing information that describes the types of system monitoring information

45 C.F.R. §§ 164.308(a)(1)(i)

NIST SP 1800-30B: Securing Telehealth Remote Patient Monitoring Ecosystem

164

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

Cybersecurity Framework v1.1 Subcategory monitored to detect potential cybersecurity events.

Device Cybersecurity Capabilities

DE.CM-2: The physical environment is monitored to detect potential cybersecurity events.

 N/A

Ability to access information about the IoT device’s cybersecurity state and other necessary data. Ability to monitor for organizationally defined cybersecurity events (e.g., expected state change) that may occur on or involving the IoT device. Ability to support a monitoring process to check for disclosure of organizational information to unauthorized entities. (The device may be able to perform this check itself or provide the information necessary for an external process to check). Ability to monitor communications traffic.

Manufacturer Nontechnical Supporting Capabilities

 

NIST SP 1800-30B: Securing Telehealth Remote Patient Monitoring Ecosystem

HIPAA Security Rule Mapping to Cybersecurity Framework Subcategory

generated from, or associated with, the IoT device and instructions for obtaining that information. Providing documentation describing the types of monitoring tools with which the IoT device is compatible, and recommendations for how to configure the IoT device to best work with such monitoring tools. Providing the details necessary to monitor IoT devices and associated systems. Providing documentation describing how to perform monitoring activities.

164.308(a)(1)(ii)(D) 164.308(a)(5)(ii)(B) 164.308(a)(5)(ii)(C) 164.308(a)(2) 164.308(a)(3)(ii)(A)

Providing descriptions of the types of physical access practices, and manufacturer suggested hardware or other types of devices, that can be used to prevent unauthorized physical access to the IoT device. Providing descriptions of the physical access security procedures the manufacturer recommends for limiting physical access to the device and to associated device controls. Providing details of indications, and recommendations for how to determine,

45 C.F.R. §§ 164.310(a)(2)(ii) 164.310(a)(2)(iii)

165

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

Cybersecurity Framework v1.1 Subcategory

DE.CM-4: Malicious code is detected.

Device Cybersecurity Capabilities

N/A

Manufacturer Nontechnical Supporting Capabilities

NIST SP 1800-30B: Securing Telehealth Remote Patient Monitoring Ecosystem

when unauthorized physical access to the IoT device was or is attempted or is occurring. Providing education for how to implement malicious code protection in the IoT device and associated systems as well as how to detect and eradicate malicious code. Providing education for how to update the IoT device and related systems malicious code protection mechanisms when new releases are available, in accordance with organizational configuration management policy and procedures. If the IoT device manufacturer provides antimalware for the associated IoT device, or if the IoT device has built-in anti-malware capabilities, the manufacturer should provide education to IoT device customers describing how to use and/or configure malicious code protection mechanisms in IoT devices, supporting anti-malware tools, and related systems. Providing education that include the details necessary to implement management and operational controls for malicious code detection and eradication.

HIPAA Security Rule Mapping to Cybersecurity Framework Subcategory

45 C.F.R. §§ 164.308(a)(1)(ii)(D) 164.308(a)(5)(ii)(B)

166

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

Cybersecurity Framework v1.1 Subcategory

Device Cybersecurity Capabilities

Manufacturer Nontechnical Supporting Capabilities

DE.CM-5: Unauthorized mobile code is detected.

N/A

N/A

DE.CM-7: Monitoring for unauthorized personnel, connections, devices, and software is performed.

  

     

Ability to support a monitoring process to check for disclosure of organizational information to unauthorized entities. (The device may be able to perform this check itself or provide the information necessary for an external process to check). Ability to monitor changes to the configuration settings. Ability to detect remote activation attempts. Ability to detect remote activation of a collaborative computing device/component (e.g., microphone, camera). Ability to detect remote activation of sensors. Ability to define the characteristics of unapproved content. Ability to scan files for unapproved content. Ability to prevent download of unapproved content. Ability to delete unapproved content. Ability to take organizationally defined actions when unauthorized hardware and software components are detected (e.g., disallow a flash

NIST SP 1800-30B: Securing Telehealth Remote Patient Monitoring Ecosystem

 

HIPAA Security Rule Mapping to Cybersecurity Framework Subcategory 45 C.F.R. §§ 164.308(a)(1)(ii)(D) 164.308(a)(5)(ii)(B)

Providing appropriate tools, assistance, instructions, or other details describing the capabilities for monitoring the IoT device and/or for the IoT device customer to report actions to the monitoring service of the manufacturer’s supporting entity. Providing the details necessary to monitor IoT devices and associated systems. Providing documentation describing details necessary to identify unauthorized use of IoT devices and their associated systems. Providing documentation that describes indicators of unauthorized use of the IoT device.

45 C.F.R. §§ 164.308(a)(1)(ii)(D) 164.308(a)(5)(ii)(B) 164.308(a)(5)(ii)(C) 164.310(a)(1) 164.310(a)(2)(ii) 164.310(a)(2)(iii)

167

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

Cybersecurity Framework v1.1 Subcategory

Device Cybersecurity Capabilities

Manufacturer Nontechnical Supporting Capabilities

HIPAA Security Rule Mapping to Cybersecurity Framework Subcategory

drive to be connected even if a Universal Serial Bus [USB] port is present). DE.CM-8: Vulnerability scans are performed.

N/A

RS.RP-1: Response plan is executed during or after an event.

RS.IM-1: Response plans incorporate lessons learned.

N/A

N/A

45 C.F.R. §§ 164.308(a)(7)(ii)(D) 164.308(a)(8) 164.316(b)(2)(iii)

RS.IM-2: Response strategies are updated.

N/A

N/A

45 C.F.R. §§ 164.308(a)(7)(ii)(D) 164.308(a)(8)

RC.RP-1: Recovery plan is executed during or after a

N/A

N/A

45 C.F.R. §§ 164.308(a)(7) 164.308(a)(7)(i) 164.308(a)(7)(ii) 164.308(a)(7)(ii)(C)

45 C.F.R. §§ 164.308(a)(1)(i) 164.308(a)(8)

N/A

Ability to respond to alerts according to predefined responses. Ability to respond following an auditing failure (either by the device or an external auditing process).

NIST SP 1800-30B: Securing Telehealth Remote Patient Monitoring Ecosystem

Providing education describing the options and recommended responses to malicious code identification within the IoT device.

45 C.F.R. §§ 164.308(a)(6)(ii) 164.308(a)(7)(i) 164.308(a)(7)(ii)(A) 164.308(a)(7)(ii)(B) 164.308(a)(7)(ii)(C) 164.310(a)(2)(i) 164.312(a)(2)(ii)

168

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

Cybersecurity Framework v1.1 Subcategory

Device Cybersecurity Capabilities

cybersecurity incident.

NIST SP 1800-30B: Securing Telehealth Remote Patient Monitoring Ecosystem

Manufacturer Nontechnical Supporting Capabilities

HIPAA Security Rule Mapping to Cybersecurity Framework Subcategory 164.310(a)(2)(i) 164.312(a)(2)(ii)

169

E-2 Device Capabilities Supporting Functional Evaluations Table E-2 below builds on the functional evaluations included in Section 6 of this document. The table lists both device cybersecurity capabilities and nontechnical supporting capabilities that map to each of the functional test cases. Selecting devices and/or third parties that provide these capabilities can help achieve the respective functional requirements.

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30. NIST SP 1800-30B: Securing Telehealth Remote Patient Monitoring Ecosystem

170

Table E-2 Device Cybersecurity Capabilities and Nontechnical Supporting Capabilities that Map to Each of the Functional Test Cases

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

Test Case Identification (ID) and Description with Relevant Cybersecurity Framework Subcategories

Device Cybersecurity Capabilities

RPM-1 Asset Management: Device Management Demonstrate the ability to verify that provisioned devices are associated with the intended patient who has enrolled in an RPM program. ID.AM-1 ID.AM-5

RPM-2 Risk Assessment: End-Point Vulnerability Scanning Demonstrate the ability to perform vulnerability scans on assets and view results in a dashboard

Ability to detect unauthorized hardware and software components.

Manufacturer Nontechnical Supporting Capabilities

Ability to differentiate between when a device will likely operate as expected from when it may be in a degraded cybersecurity state.

NIST SP 1800-30B: Securing Telehealth Remote Patient Monitoring Ecosystem

Providing details for how to establish unique identification for each IoT device associated with the system and critical system components within which it is used. Providing IoT device customers with the details necessary to establish and implement unique identification for each IoT device associated with the system and critical system components within which it is used. Providing IoT device customers with the details necessary to require unique identifiers for each IoT device associated with the system and critical system components within which it is used. Providing details for performing the tests necessary for IoT device and related system software updates, for effectiveness and to identify potential side effects, before installation. Providing communications describing the types of security and privacy tests necessary for the IoT device and software before installation.

171

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

Test Case Identification (ID) and Description with Relevant Cybersecurity Framework Subcategories

Device Cybersecurity Capabilities

format with risk-scoring evaluations. ID.RA-1 ID.RA-4 ID.RA-5 ID.RA-6

Manufacturer Nontechnical Supporting Capabilities

RPM-3 Identity Management, Authentication, and

 

Ability to uniquely identify the IoT device logically. Ability to uniquely identify a remote IoT device.

NIST SP 1800-30B: Securing Telehealth Remote Patient Monitoring Ecosystem

Providing training and awareness information to IoT device customers that describe newly identified vulnerabilities and threats (such as zero-day malware) for the associated IoT device. Providing the details necessary for the installation of IoT devices and associated systems security-relevant software updates within an organizationally defined time period from the vendor release of the updates. Providing education describing the operational impacts of the anti-malware activities on mission critical processes in the system where the IoT device is used. Providing education explaining the responsibilities of IoT device customers to perform their own risk assessments, using information provided by the manufacturer, to determine the risks the IoT device will bring into the IoT device customer’s systems. Providing details for how to establish unique identification for each IoT device associated with the system and critical system components within which it is used.

172

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

Test Case Identification (ID) and Description with Relevant Cybersecurity Framework Subcategories Access Control: Rolebased Access Demonstrate the ability to limit and disable access to data by implementing role-based access control on the Vivify platform. PR.AC-1 PR.AC-2 PR.AC-3 PR.AC-4 PR.AC-5 PR.AC-6

Device Cybersecurity Capabilities

        

Ability for the device to support a unique device ID (e.g., to allow it to be linked to the person or process assigned to use the IoT device). Ability to configure IoT device access control policies using IoT device identity. o Ability to hide IoT device identity from non-authorized entities. o Ability for the IoT device to differentiate between authorized and unauthorized remote users. o Ability for the IoT device to differentiate between authorized and unauthorized physical device users. Ability to verify the identity of an IoT device. Ability to add a unique physical identifier at an external or internal location on the device authorized entities can access. Ability for the IoT device to hide or mask authentication information during authentication process. Ability to set and change authentication configurations, policies and limitations settings for the IoT device. Ability to revoke access to the device. Ability to create unique IoT device user accounts. Ability to identify unique IoT device user accounts. Ability to create organizationally defined accounts that support privileged roles with automated expiration conditions. Ability to establish organizationally defined user actions for accessing the IoT device and/or device interface.

NIST SP 1800-30B: Securing Telehealth Remote Patient Monitoring Ecosystem

Manufacturer Nontechnical Supporting Capabilities

 

Providing communications and documentation detailing how to perform account management activities, using the technical IoT device capabilities, or through supporting systems and/or tools. Providing the details necessary to establish and implement unique identification for each IoT device associated with the system and critical system components within which it is used. Providing the details necessary to require unique identifiers for each IoT device associated with the system and critical system components within which it is used. Providing education explaining how to establish and enforce approved authorizations for logical access to IoT device information and system resources. Providing education explaining how to control access to IoT devices implemented within IoT device customer information systems. Providing education explaining how to enforce authorized access at the system level. Providing descriptions of the types of physical access practices, and manufacturer suggested

173

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

Test Case Identification (ID) and Description with Relevant Cybersecurity Framework Subcategories

Device Cybersecurity Capabilities

       

Ability to enable automation and reporting of account management activities. o Ability to assign access to IoT device audit controls to specific roles or organizationally defined personnel. o Ability to control access to IoT device audit data. o Ability to identify the user, process or device requesting access to the audit/accountability information (i.e., to ensure only authorized users and/or devices have access). Ability to establish conditions for shared/group accounts on the IoT device. Ability to administer conditions for shared/group accounts on the IoT device. Ability to restrict the use of shared/group accounts on the IoT device according to organizationally defined conditions. Ability to authenticate external users and systems. Ability to securely interact with authorized external, third-party systems. Ability to identify when an external system meets the required security requirements for a connection. Ability to establish secure communications with internal systems when the device is operating on external networks. Ability to establish requirements for remote access to the IoT device and/or IoT device interface, including: o usage restrictions

NIST SP 1800-30B: Securing Telehealth Remote Patient Monitoring Ecosystem

Manufacturer Nontechnical Supporting Capabilities

hardware or other types of devices, that can be used to prevent unauthorized physical access to the IoT device based upon the determined risk level that the device brings to the IoT customer’s system. Providing descriptions of the physical access security procedures the manufacturer recommends for limiting physical access to the device and to associated device controls. Providing details of indications, and recommendations for how to determine, when unauthorized physical access to the IoT device was or is attempted or is occurring. Providing the tools, assistance, instructions, and other types of information to support establishing a hierarchy of role-based privileges within the IoT device. Providing details about the specific types of manufacturer’s needs to access the IoT device interfaces; such as for specific support, updates, ongoing maintenance, and other purposes. Providing documentation with instructions for how to restrict interface connections that enable specific activities.

174

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

Test Case Identification (ID) and Description with Relevant Cybersecurity Framework Subcategories

Device Cybersecurity Capabilities

      

 

o configuration requirements o connection requirements o manufacturer established requirement Ability to enforce the established local and remote access requirements. Ability to prevent external access to the IoT device management interface. Ability to control the IoT device’s logical interface (e.g., locally or remotely). Ability to detect remote activation attempts. Ability to detect remote activation of a collaborative computing device/component (e.g., microphone, camera). Ability to detect remote activation of sensors. Ability to establish access to the IoT device to perform organizationally defined user actions without identification or authentication. Ability to assign roles to IoT device user accounts. Ability to support a hierarchy of logical access privileges for the IoT device based on roles (e.g., admin, emergency, user, local, temporary) o Ability to establish user accounts to support rolebased logical access privileges. o Ability to administer user accounts to support rolebased logical access privileges.

NIST SP 1800-30B: Securing Telehealth Remote Patient Monitoring Ecosystem

Manufacturer Nontechnical Supporting Capabilities

Providing descriptions of the types of access to the IoT device that the manufacturer will require on an ongoing or regular basis. Providing detailed instructions for how to implement management and operational controls based on the role of the IoT device user, and not on an individual basis. Providing documentation and/or other communications describing how to implement management and operational controls to protect data obtained from IoT devices and associated systems from unauthorized access, modification, and deletion. Providing a detailed description of the other types of devices and systems that will access the IoT device during customer use of the device, and how they will access it. Providing communications and detailed instructions for implementing a hierarchy of privilege levels to use with the IoT device and/or necessary associated information systems. Providing communications and documentation detailing how to perform

175

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

Test Case Identification (ID) and Description with Relevant Cybersecurity Framework Subcategories

Device Cybersecurity Capabilities

Ability to use organizationally defined roles to define each user account’s access and permitted device actions. Ability to support multiple levels of user/process account functionality and roles for the IoT device. Ability to apply least privilege to user accounts (i.e., to ensure that the processes operate at privilege levels no higher than necessary to accomplish required functions) o Ability to create additional processes, roles (e.g., admin, emergency, temporary) and accounts as necessary to achieve least privilege. o Ability to apply least privilege settings within the device (i.e., to ensure that the processes operate at privilege levels no higher than necessary to accomplish required functions). o Ability to limit access to privileged device settings that are used to establish and administer authorization requirements. o Ability for authorized users to access privileged settings. Ability to implement dynamic access control approaches (e.g., service-oriented architectures) that rely on: o run-time access control decisions facilitated by dynamic privilege management. o Organizationally defined actions to access/use device

Manufacturer Nontechnical Supporting Capabilities

o

 

NIST SP 1800-30B: Securing Telehealth Remote Patient Monitoring Ecosystem

account management activities, using the technical IoT device capabilities, or through supporting systems and/or tools. Providing education and supporting materials explaining how to establish roles and responsibilities for IoT device data security, using the device capabilities and/or other services that communicate or interface with the device. Providing education and supporting materials describing the IoT device capabilities for rolebased controls, and how to establish different roles within the IoT device. Providing education and supporting materials for how to establish roles to support IoT device policies, procedures and associated documentation.

176

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

Test Case Identification (ID) and Description with Relevant Cybersecurity Framework Subcategories

Device Cybersecurity Capabilities

 

 

   

Manufacturer Nontechnical Supporting Capabilities

Ability to allow information sharing capabilities based upon the type and/or role of user attempting to share the information. Ability to restrict access to IoT device software, hardware, and data based on user account roles, used with proper authentication of the identity of the user to determine type of authorization. Ability to establish pre-defined restrictions for information searches within the device. Ability to establish limits on authorized concurrent device sessions for: o user accounts o roles o groups o dates o times o locations o manufacturer-established parameters Ability to restrict updating actions to authorized entities. Ability to restrict access to the cybersecurity state indicator to authorized entities. Ability to enforce the established local and remote access requirements. Ability to update the device’s software through remote (e.g., network download) and/or local (e.g., removable media) means.

NIST SP 1800-30B: Securing Telehealth Remote Patient Monitoring Ecosystem

177

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

Test Case Identification (ID) and Description with Relevant Cybersecurity Framework Subcategories

Device Cybersecurity Capabilities

      RPM-4 Identity Management, Authentication, and Access Control: Domain User Authentication and Authorization Demonstrate the ability to create new domain users and enforce restrictions on nonadmin users. PR.AC-1 PR.AC-2 PR.AC-3 PR.AC-4 PR.AC-5

  

 

Ability to store and process session identifiers. Ability to identify and track sessions with identifiers. Ability to enforce access to memory space through the kernel. Ability to prevent a process from accessing memory space of another process. Ability to obtain and validate certificates. Ability to identify unique users interacting with the device (to allow for user session monitoring). Ability to uniquely identify the IoT device logically. Ability to uniquely identify a remote IoT device. Ability for the device to support a unique device ID (e.g., to allow it to be linked to the person or process assigned to use the IoT device). Ability to configure IoT device access control policies using IoT device identity. o Ability to hide IoT device identity from non-authorized entities. o Ability for the IoT device to differentiate between authorized and unauthorized remote users. o Ability for the IoT device to differentiate between authorized and unauthorized physical device users. Ability to verify the identity of an IoT device. Ability to add a unique physical identifier at an external or internal location on the device authorized entities can access.

NIST SP 1800-30B: Securing Telehealth Remote Patient Monitoring Ecosystem

Manufacturer Nontechnical Supporting Capabilities

Providing details for how to establish unique identification for each IoT device associated with the system and critical system components within which it is used. Providing communications and documentation detailing how to perform account management activities, using the technical IoT device capabilities, or through supporting systems and/or tools. Providing the details necessary to establish and implement unique identification for each IoT device associated with the system and critical system components within which it is used. Providing the details necessary to require unique identifiers for each IoT device

178

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

Test Case Identification (ID) and Description with Relevant Cybersecurity Framework Subcategories

Device Cybersecurity Capabilities

PR.AC-6

       

 

Ability for the IoT device to hide or mask authentication information during authentication process. Ability to set and change authentication configurations, policies and limitations settings for the IoT device. Ability to revoke access to the device. Ability to create unique IoT device user accounts. Ability to identify unique IoT device user accounts. Ability to create organizationally defined accounts that support privileged roles with automated expiration conditions. Ability to establish organizationally defined user actions for accessing the IoT device and/or device interface. Ability to enable automation and reporting of account management activities. o Ability to assign access to IoT device audit controls to specific roles or organizationally defined personnel. o Ability to control access to IoT device audit data. o Ability to identify the user, process or device requesting access to the audit/accountability information (i.e., to ensure only authorized users and/or devices have access). Ability to establish conditions for shared/group accounts on the IoT device. Ability to administer conditions for shared/group accounts on the IoT device.

NIST SP 1800-30B: Securing Telehealth Remote Patient Monitoring Ecosystem

Manufacturer Nontechnical Supporting Capabilities

 

associated with the system and critical system components within which it is used. Providing education explaining how to establish and enforce approved authorizations for logical access to IoT device information and system resources. Providing education explaining how to control access to IoT devices implemented within IoT device customer information systems. Providing education explaining how to enforce authorized access at the system level. Providing descriptions of the types of physical access practices, and manufacturer suggested hardware or other types of devices, that can be used to prevent unauthorized physical access to the IoT device based upon the determined risk level that the device brings to the IoT customer’s system. Providing descriptions of the physical access security procedures the manufacturer recommends for limiting physical access to the device and to associated device controls. Providing details of indications, and recommendations for how to determine,

179

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

Test Case Identification (ID) and Description with Relevant Cybersecurity Framework Subcategories

Device Cybersecurity Capabilities

     

     

Ability to restrict the use of shared/group accounts on the IoT device according to organizationally defined conditions. Ability to authenticate external users and systems. Ability to securely interact with authorized external, third-party systems. Ability to identify when an external system meets the required security requirements for a connection. Ability to establish secure communications with internal systems when the device is operating on external networks. Ability to establish requirements for remote access to the IoT device and/or IoT device interface, including: o usage restrictions o configuration requirements o connection requirements o manufacturer established requirement Ability to enforce the established local and remote access requirements. Ability to prevent external access to the IoT device management interface. Ability to control the IoT device’s logical interface (e.g., locally or remotely). Ability to detect remote activation attempts. Ability to detect remote activation of a collaborative computing device/component (e.g., microphone, camera). Ability to detect remote activation of sensors.

NIST SP 1800-30B: Securing Telehealth Remote Patient Monitoring Ecosystem

Manufacturer Nontechnical Supporting Capabilities

when unauthorized physical access to the IoT device was or is attempted or is occurring. Providing the tools, assistance, instructions, and other types of information to support establishing a hierarchy of role-based privileges within the IoT device. Providing details about the specific types of manufacturer’s needs to access the IoT device interfaces; such as for specific support, updates, ongoing maintenance, and other purposes. Providing documentation with instructions for how to restrict interface connections that enable specific activities. Providing descriptions of the types of access to the IoT device that the manufacturer will require on an ongoing or regular basis. Providing detailed instructions for how to implement management and operational controls based on the role of the IoT device user, and not on an individual basis. Providing documentation and/or other communications describing how to implement management and operational controls to protect data obtained from IoT

180

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

Test Case Identification (ID) and Description with Relevant Cybersecurity Framework Subcategories

Device Cybersecurity Capabilities

 

 

Ability to establish access to the IoT device to perform organizationally defined user actions without identification or authentication. Ability to assign roles to IoT device user accounts. Ability to support a hierarchy of logical access privileges for the IoT device based on roles (e.g., admin, emergency, user, local, temporary) o Ability to establish user accounts to support rolebased logical access privileges. o Ability to administer user accounts to support rolebased logical access privileges. o Ability to use organizationally defined roles to define each user account’s access and permitted device actions. Ability to support multiple levels of user/process account functionality and roles for the IoT device. Ability to apply least privilege to user accounts (i.e., to ensure that the processes operate at privilege levels no higher than necessary to accomplish required functions) o Ability to create additional processes, roles (e.g., admin, emergency, temporary) and accounts as necessary to achieve least privilege. o Ability to apply least privilege settings within the device (i.e., to ensure that the processes operate at

NIST SP 1800-30B: Securing Telehealth Remote Patient Monitoring Ecosystem

Manufacturer Nontechnical Supporting Capabilities

devices and associated systems from unauthorized access, modification, and deletion. Providing a detailed description of the other types of devices and systems that will access the IoT device during customer use of the device, and how they will access it. Providing communications and detailed instructions for implementing a hierarchy of privilege levels to use with the IoT device and/or necessary associated information systems. Providing communications and documentation detailing how to perform account management activities, using the technical IoT device capabilities, or through supporting systems and/or tools. Providing education and supporting materials explaining how to establish roles and responsibilities for IoT device data security, using the device capabilities and/or other services that communicate or interface with the device. Providing education and supporting materials describing the IoT device capabilities for role-

181

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

Test Case Identification (ID) and Description with Relevant Cybersecurity Framework Subcategories

Device Cybersecurity Capabilities

 

 

privilege levels no higher than necessary to accomplish required functions). o Ability to limit access to privileged device settings that are used to establish and administer authorization requirements. o Ability for authorized users to access privileged settings. Ability to implement dynamic access control approaches (e.g., service-oriented architectures) that rely on: o run-time access control decisions facilitated by dynamic privilege management. o Organizationally defined actions to access/use device Ability to allow information sharing capabilities based upon the type and/or role of user attempting to share the information. Ability to restrict access to IoT device software, hardware, and data based on user account roles, used with proper authentication of the identity of the user to determine type of authorization. Ability to establish pre-defined restrictions for information searches within the device. Ability to establish limits on authorized concurrent device sessions for: o user accounts o roles o groups

NIST SP 1800-30B: Securing Telehealth Remote Patient Monitoring Ecosystem

Manufacturer Nontechnical Supporting Capabilities

based controls, and how to establish different roles within the IoT device. Providing education and supporting materials for how to establish roles to support IoT device policies, procedures and associated documentation.

182

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

Test Case Identification (ID) and Description with Relevant Cybersecurity Framework Subcategories

Device Cybersecurity Capabilities

   

      RPM-5 Identity Management, Authentication, and Access Control: Network

  

o dates o times o locations o manufacturer-established parameters Ability to restrict updating actions to authorized entities. Ability to restrict access to the cybersecurity state indicator to authorized entities. Ability to enforce the established local and remote access requirements. Ability to update the device’s software through remote (e.g., network download) and/or local (e.g., removable media) means. Ability to store and process session identifiers. Ability to identify and track sessions with identifiers. Ability to enforce access to memory space through the kernel. Ability to prevent a process from accessing memory space of another process. Ability to obtain and validate certificates. Ability to identify unique users interacting with the device (to allow for user session monitoring). Ability to uniquely identify the IoT device logically. Ability to uniquely identify a remote IoT device. Ability for the device to support a unique device ID (e.g., to allow it to be linked to the person or process assigned to use the IoT device).

NIST SP 1800-30B: Securing Telehealth Remote Patient Monitoring Ecosystem

Manufacturer Nontechnical Supporting Capabilities

Providing details for how to establish unique identification for each IoT device associated with the system and critical system components within which it is used.

183

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

Test Case Identification (ID) and Description with Relevant Cybersecurity Framework Subcategories Segmentation and Access Control Policy Demonstrate the use of network segmentation and an access control policy to allow permitted traffic to selected network devices. PR.AC-1 PR.AC-2 PR.AC-3 PR.AC-4 PR.AC-5 PR.AC-6

Device Cybersecurity Capabilities

         

Ability to configure IoT device access control policies using IoT device identity. o Ability to hide IoT device identity from non-authorized entities. o Ability for the IoT device to differentiate between authorized and unauthorized remote users. o Ability for the IoT device to differentiate between authorized and unauthorized physical device users. Ability to verify the identity of an IoT device. Ability to add a unique physical identifier at an external or internal location on the device authorized entities can access. Ability for the IoT device to hide or mask authentication information during authentication process. Ability to set and change authentication configurations, policies and limitations settings for the IoT device. Ability to revoke access to the device. Ability to create unique IoT device user accounts. Ability to identify unique IoT device user accounts. Ability to create organizationally defined accounts that support privileged roles with automated expiration conditions. Ability to establish organizationally defined user actions for accessing the IoT device and/or device interface. Ability to enable automation and reporting of account management activities.

NIST SP 1800-30B: Securing Telehealth Remote Patient Monitoring Ecosystem

Manufacturer Nontechnical Supporting Capabilities

 

Providing communications and documentation detailing how to perform account management activities, using the technical IoT device capabilities, or through supporting systems and/or tools. Providing the details necessary to establish and implement unique identification for each IoT device associated with the system and critical system components within which it is used. Providing the details necessary to require unique identifiers for each IoT device associated with the system and critical system components within which it is used. Providing education explaining how to establish and enforce approved authorizations for logical access to IoT device information and system resources. Providing education explaining how to control access to IoT devices implemented within IoT device customer information systems. Providing education explaining how to enforce authorized access at the system level. Providing descriptions of the types of physical access practices, and manufacturer suggested

184

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

Test Case Identification (ID) and Description with Relevant Cybersecurity Framework Subcategories

Device Cybersecurity Capabilities

Ability to assign access to IoT device audit controls to specific roles or organizationally defined personnel. o Ability to control access to IoT device audit data. o Ability to identify the user, process or device requesting access to the audit/accountability information (i.e., to ensure only authorized users and/or devices have access). Ability to establish conditions for shared/group accounts on the IoT device. Ability to administer conditions for shared/group accounts on the IoT device. Ability to restrict the use of shared/group accounts on the IoT device according to organizationally defined conditions. Ability to authenticate external users and systems. Ability to securely interact with authorized external, third-party systems. Ability to identify when an external system meets the required security requirements for a connection. Ability to establish secure communications with internal systems when the device is operating on external networks. Ability to establish requirements for remote access to the IoT device and/or IoT device interface, including: o usage restrictions o configuration requirements o connection requirements

Manufacturer Nontechnical Supporting Capabilities

o

       

NIST SP 1800-30B: Securing Telehealth Remote Patient Monitoring Ecosystem

hardware or other types of devices, that can be used to prevent unauthorized physical access to the IoT device based upon the determined risk level that the device brings to the IoT customer’s system. Providing descriptions of the physical access security procedures the manufacturer recommends for limiting physical access to the device and to associated device controls. Providing details of indications, and recommendations for how to determine, when unauthorized physical access to the IoT device was or is attempted or is occurring. Providing the tools, assistance, instructions, and other types of information to support establishing a hierarchy of role-based privileges within the IoT device. Providing details about the specific types of manufacturer’s needs to access the IoT device interfaces; such as for specific support, updates, ongoing maintenance, and other purposes. Providing documentation with instructions for how to restrict interface connections that enable specific activities.

185

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

Test Case Identification (ID) and Description with Relevant Cybersecurity Framework Subcategories

Device Cybersecurity Capabilities

      

 

o manufacturer established requirement Ability to enforce the established local and remote access requirements. Ability to prevent external access to the IoT device management interface. Ability to control the IoT device’s logical interface (e.g., locally or remotely). Ability to detect remote activation attempts. Ability to detect remote activation of a collaborative computing device/component (e.g., microphone, camera). Ability to detect remote activation of sensors. Ability to establish access to the IoT device to perform organizationally defined user actions without identification or authentication. Ability to assign roles to IoT device user accounts. Ability to support a hierarchy of logical access privileges for the IoT device based on roles (e.g., admin, emergency, user, local, temporary) o Ability to establish user accounts to support rolebased logical access privileges. o Ability to administer user accounts to support rolebased logical access privileges. o Ability to use organizationally defined roles to define each user account’s access and permitted device actions.

NIST SP 1800-30B: Securing Telehealth Remote Patient Monitoring Ecosystem

Manufacturer Nontechnical Supporting Capabilities

Providing descriptions of the types of access to the IoT device that the manufacturer will require on an ongoing or regular basis. Providing detailed instructions for how to implement management and operational controls based on the role of the IoT device user, and not on an individual basis. Providing documentation and/or other communications describing how to implement management and operational controls to protect data obtained from IoT devices and associated systems from unauthorized access, modification, and deletion. Providing a detailed description of the other types of devices and systems that will access the IoT device during customer use of the device, and how they will access it. Providing communications and detailed instructions for implementing a hierarchy of privilege levels to use with the IoT device and/or necessary associated information systems. Providing communications and documentation detailing how to perform

186

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

Test Case Identification (ID) and Description with Relevant Cybersecurity Framework Subcategories

Device Cybersecurity Capabilities

 

Ability to support multiple levels of user/process account functionality and roles for the IoT device. Ability to apply least privilege to user accounts (i.e., to ensure that the processes operate at privilege levels no higher than necessary to accomplish required functions) o Ability to create additional processes, roles (e.g., admin, emergency, temporary) and accounts as necessary to achieve least privilege. o Ability to apply least privilege settings within the device (i.e., to ensure that the processes operate at privilege levels no higher than necessary to accomplish required functions). o Ability to limit access to privileged device settings that are used to establish and administer authorization requirements. o Ability for authorized users to access privileged settings. Ability to implement dynamic access control approaches (e.g., service-oriented architectures) that rely on: o run-time access control decisions facilitated by dynamic privilege management. o Organizationally defined actions to access/use device Ability to allow information sharing capabilities based upon the type and/or role of user attempting to share the information.

NIST SP 1800-30B: Securing Telehealth Remote Patient Monitoring Ecosystem

Manufacturer Nontechnical Supporting Capabilities

account management activities, using the technical IoT device capabilities, or through supporting systems and/or tools. Providing education and supporting materials explaining how to establish roles and responsibilities for IoT device data security, using the device capabilities and/or other services that communicate or interface with the device. Providing education and supporting materials describing the IoT device capabilities for rolebased controls, and how to establish different roles within the IoT device. Providing education and supporting materials for how to establish roles to support IoT device policies, procedures and associated documentation.

187

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

Test Case Identification (ID) and Description with Relevant Cybersecurity Framework Subcategories

Device Cybersecurity Capabilities

 

   

 

Manufacturer Nontechnical Supporting Capabilities

Ability to restrict access to IoT device software, hardware, and data based on user account roles, used with proper authentication of the identity of the user to determine type of authorization. Ability to establish pre-defined restrictions for information searches within the device. Ability to establish limits on authorized concurrent device sessions for: o user accounts o roles o groups o dates o times o locations o manufacturer-established parameters Ability to restrict updating actions to authorized entities. Ability to restrict access to the cybersecurity state indicator to authorized entities. Ability to enforce the established local and remote access requirements. Ability to update the device’s software through remote (e.g., network download) and/or local (e.g., removable media) means. Ability to store and process session identifiers. Ability to identify and track sessions with identifiers.

NIST SP 1800-30B: Securing Telehealth Remote Patient Monitoring Ecosystem

188

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

Test Case Identification (ID) and Description with Relevant Cybersecurity Framework Subcategories

Device Cybersecurity Capabilities

    RPM-6 Security Continuous Monitoring: Malware Protection Demonstrate the ability to protect the network and end points from malicious services by blocking the service before a connection is made. DE.CM-1 DE.CM-2 DE.CM-4 DE.CM-7 DE.CM-8

  

      

Ability to enforce access to memory space through the kernel. Ability to prevent a process from accessing memory space of another process. Ability to obtain and validate certificates. Ability to identify unique users interacting with the device (to allow for user session monitoring). Ability to monitor specific actions based on the IoT device identity. Ability to access information about the IoT device’s cybersecurity state and other necessary data. Ability to monitor for organizationally defined cybersecurity events (e.g., expected state change) that may occur on or involving the IoT device. Ability to support a monitoring process to check for disclosure of organizational information to unauthorized entities. (The device may be able to perform this check itself or provide the information necessary for an external process to check). Ability to monitor communications traffic. Ability to monitor changes to the configuration settings. Ability to detect remote activation attempts. Ability to detect remote activation of a collaborative computing device/component (e.g., microphone, camera). Ability to detect remote activation of sensors. Ability to define the characteristics of unapproved content. Ability to scan files for unapproved content.

NIST SP 1800-30B: Securing Telehealth Remote Patient Monitoring Ecosystem

Manufacturer Nontechnical Supporting Capabilities

  

Providing information that describes the types of system monitoring information generated from, or associated with, the IoT device and instructions for obtaining that information. Providing documentation describing the types of monitoring tools with which the IoT device is compatible, and recommendations for how to configure the IoT device to best work with such monitoring tools. Providing the details necessary to monitor IoT devices and associated systems. Providing documentation describing how to perform monitoring activities. Providing descriptions of the types of physical access practices, and manufacturer suggested hardware or other types of devices, that can be used to prevent unauthorized physical access to the IoT device.

189

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

Test Case Identification (ID) and Description with Relevant Cybersecurity Framework Subcategories

Device Cybersecurity Capabilities

  

Ability to prevent download of unapproved content. Ability to delete unapproved content. Ability to take organizationally defined actions when unauthorized hardware and software components are detected (e.g., disallow a flash drive to be connected even if a Universal Serial Bus [USB] port is present).

Manufacturer Nontechnical Supporting Capabilities

NIST SP 1800-30B: Securing Telehealth Remote Patient Monitoring Ecosystem

Providing descriptions of the physical access security procedures the manufacturer recommends for limiting physical access to the device and to associated device controls. Providing details of indications, and recommendations for how to determine, when unauthorized physical access to the IoT device was or is attempted or is occurring. Providing education for how to implement malicious code protection in the IoT device and associated systems as well as how to detect and eradicate malicious code. Providing education for how to update the IoT device and related systems malicious code protection mechanisms when new releases are available, in accordance with organizational configuration management policy and procedures. If the IoT device manufacturer provides antimalware for the associated IoT device, or if the IoT device has built-in anti-malware capabilities, the manufacturer should provide education to IoT device customers describing how to use and/or configure malicious code protection mechanisms in IoT devices,

190

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

Test Case Identification (ID) and Description with Relevant Cybersecurity Framework Subcategories

Device Cybersecurity Capabilities

Manufacturer Nontechnical Supporting Capabilities

RPM-7 Security Continuous Monitoring: Malicious Activity Detection Demonstrate the ability to detect anomalous network

  

Ability to monitor specific actions based on the IoT device identity. Ability to access information about the IoT device’s cybersecurity state and other necessary data. Ability to monitor for organizationally defined cybersecurity events (e.g., expected state change) that may occur on or involving the IoT device.

NIST SP 1800-30B: Securing Telehealth Remote Patient Monitoring Ecosystem

supporting anti-malware tools, and related systems. Providing education that include the details necessary to implement management and operational controls for malicious code detection and eradication. Providing appropriate tools, assistance, instructions, or other details describing the capabilities for monitoring the IoT device and/or for the IoT device customer to report actions to the monitoring service of the manufacturer’s supporting entity. Providing documentation describing details necessary to identify unauthorized use of IoT devices and their associated systems. Providing documentation that describes indicators of unauthorized use of the IoT device. Providing information that describes the types of system monitoring information generated from, or associated with, the IoT device and instructions for obtaining that information. Providing documentation describing the types of monitoring tools with which the IoT device

191

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

Test Case Identification (ID) and Description with Relevant Cybersecurity Framework Subcategories traffic and create an alert for further investigation. DE.CM-1 DE.CM-2 DE.CM-4 DE.CM-7 DE.CM-8

Device Cybersecurity Capabilities

         

Ability to support a monitoring process to check for disclosure of organizational information to unauthorized entities. (The device may be able to perform this check itself or provide the information necessary for an external process to check). Ability to monitor communications traffic. Ability to monitor changes to the configuration settings. Ability to detect remote activation attempts. Ability to detect remote activation of a collaborative computing device/component (e.g., microphone, camera). Ability to detect remote activation of sensors. Ability to define the characteristics of unapproved content. Ability to scan files for unapproved content. Ability to prevent download of unapproved content. Ability to delete unapproved content. Ability to take organizationally defined actions when unauthorized hardware and software components are detected (e.g., disallow a flash drive to be connected even if a Universal Serial Bus [USB] port is present).

Manufacturer Nontechnical Supporting Capabilities

  

NIST SP 1800-30B: Securing Telehealth Remote Patient Monitoring Ecosystem

is compatible, and recommendations for how to configure the IoT device to best work with such monitoring tools. Providing the details necessary to monitor IoT devices and associated systems. Providing documentation describing how to perform monitoring activities. Providing descriptions of the types of physical access practices, and manufacturer suggested hardware or other types of devices, that can be used to prevent unauthorized physical access to the IoT device. Providing descriptions of the physical access security procedures the manufacturer recommends for limiting physical access to the device and to associated device controls. Providing details of indications, and recommendations for how to determine, when unauthorized physical access to the IoT device was or is attempted or is occurring. Providing education for how to implement malicious code protection in the IoT device and associated systems as well as how to detect and eradicate malicious code.

192

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

Test Case Identification (ID) and Description with Relevant Cybersecurity Framework Subcategories

Device Cybersecurity Capabilities

Manufacturer Nontechnical Supporting Capabilities

NIST SP 1800-30B: Securing Telehealth Remote Patient Monitoring Ecosystem

Providing education for how to update the IoT device and related systems malicious code protection mechanisms when new releases are available, in accordance with organizational configuration management policy and procedures. If the IoT device manufacturer provides antimalware for the associated IoT device, or if the IoT device has built-in anti-malware capabilities, the manufacturer should provide education to IoT device customers describing how to use and/or configure malicious code protection mechanisms in IoT devices, supporting anti-malware tools, and related systems. Providing education that include the details necessary to implement management and operational controls for malicious code detection and eradication. Providing appropriate tools, assistance, instructions, or other details describing the capabilities for monitoring the IoT device and/or for the IoT device customer to report actions to the monitoring service of the manufacturer’s supporting entity.

193

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

Test Case Identification (ID) and Description with Relevant Cybersecurity Framework Subcategories

Device Cybersecurity Capabilities

Manufacturer Nontechnical Supporting Capabilities

RPM-8 Security Continuous Monitoring: End-Point Monitoring and Protection Demonstrate the ability to detect unusual authentication behaviors and file integrity changes on protected end points. DE.CM-1 DE.CM-2 DE.CM-4 DE.CM-7 DE.CM-8

  

      

Ability to monitor specific actions based on the IoT device identity. Ability to access information about the IoT device’s cybersecurity state and other necessary data. Ability to monitor for organizationally defined cybersecurity events (e.g., expected state change) that may occur on or involving the IoT device. Ability to support a monitoring process to check for disclosure of organizational information to unauthorized entities. (The device may be able to perform this check itself or provide the information necessary for an external process to check). Ability to monitor communications traffic. Ability to monitor changes to the configuration settings. Ability to detect remote activation attempts. Ability to detect remote activation of a collaborative computing device/component (e.g., microphone, camera). Ability to detect remote activation of sensors. Ability to define the characteristics of unapproved content. Ability to scan files for unapproved content.

NIST SP 1800-30B: Securing Telehealth Remote Patient Monitoring Ecosystem

  

Providing documentation describing details necessary to identify unauthorized use of IoT devices and their associated systems. Providing documentation that describes indicators of unauthorized use of the IoT device. Providing information that describes the types of system monitoring information generated from, or associated with, the IoT device and instructions for obtaining that information. Providing documentation describing the types of monitoring tools with which the IoT device is compatible, and recommendations for how to configure the IoT device to best work with such monitoring tools. Providing the details necessary to monitor IoT devices and associated systems. Providing documentation describing how to perform monitoring activities. Providing descriptions of the types of physical access practices, and manufacturer suggested hardware or other types of devices, that can be used to prevent unauthorized physical access to the IoT device.

194

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

Test Case Identification (ID) and Description with Relevant Cybersecurity Framework Subcategories

Device Cybersecurity Capabilities

  

Ability to prevent download of unapproved content. Ability to delete unapproved content. Ability to take organizationally defined actions when unauthorized hardware and software components are detected (e.g., disallow a flash drive to be connected even if a Universal Serial Bus [USB] port is present).

Manufacturer Nontechnical Supporting Capabilities

NIST SP 1800-30B: Securing Telehealth Remote Patient Monitoring Ecosystem

Providing descriptions of the physical access security procedures the manufacturer recommends for limiting physical access to the device and to associated device controls. Providing details of indications, and recommendations for how to determine, when unauthorized physical access to the IoT device was or is attempted or is occurring. Providing education for how to implement malicious code protection in the IoT device and associated systems as well as how to detect and eradicate malicious code. Providing education for how to update the IoT device and related systems malicious code protection mechanisms when new releases are available, in accordance with organizational configuration management policy and procedures. If the IoT device manufacturer provides antimalware for the associated IoT device, or if the IoT device has built-in anti-malware capabilities, the manufacturer should provide education to IoT device customers describing how to use and/or configure malicious code protection mechanisms in IoT devices,

195

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

Test Case Identification (ID) and Description with Relevant Cybersecurity Framework Subcategories

Device Cybersecurity Capabilities

Manufacturer Nontechnical Supporting Capabilities

RPM-9 Security Continuous Monitoring: End-Point Network Access Monitoring This test case demonstrates the ability to create alarms for

  

Ability to monitor specific actions based on the IoT device identity. Ability to access information about the IoT device’s cybersecurity state and other necessary data. Ability to monitor for organizationally defined cybersecurity events (e.g., expected state change) that may occur on or involving the IoT device.

NIST SP 1800-30B: Securing Telehealth Remote Patient Monitoring Ecosystem

supporting anti-malware tools, and related systems. Providing education that include the details necessary to implement management and operational controls for malicious code detection and eradication. Providing appropriate tools, assistance, instructions, or other details describing the capabilities for monitoring the IoT device and/or for the IoT device customer to report actions to the monitoring service of the manufacturer’s supporting entity. Providing documentation describing details necessary to identify unauthorized use of IoT devices and their associated systems. Providing documentation that describes indicators of unauthorized use of the IoT device. Providing information that describes the types of system monitoring information generated from, or associated with, the IoT device and instructions for obtaining that information. Providing documentation describing the types of monitoring tools with which the IoT device

196

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

Test Case Identification (ID) and Description with Relevant Cybersecurity Framework Subcategories unauthorized network traffic. DE.CM-1 DE.CM-2 DE.CM-4 DE.CM-7 DE.CM-8

Device Cybersecurity Capabilities

         

Ability to support a monitoring process to check for disclosure of organizational information to unauthorized entities. (The device may be able to perform this check itself or provide the information necessary for an external process to check). Ability to monitor communications traffic. Ability to monitor changes to the configuration settings. Ability to detect remote activation attempts. Ability to detect remote activation of a collaborative computing device/component (e.g., microphone, camera). Ability to detect remote activation of sensors. Ability to define the characteristics of unapproved content. Ability to scan files for unapproved content. Ability to prevent download of unapproved content. Ability to delete unapproved content. Ability to take organizationally defined actions when unauthorized hardware and software components are detected (e.g., disallow a flash drive to be connected even if a Universal Serial Bus [USB] port is present).

Manufacturer Nontechnical Supporting Capabilities

  

NIST SP 1800-30B: Securing Telehealth Remote Patient Monitoring Ecosystem

is compatible, and recommendations for how to configure the IoT device to best work with such monitoring tools. Providing the details necessary to monitor IoT devices and associated systems. Providing documentation describing how to perform monitoring activities. Providing descriptions of the types of physical access practices, and manufacturer suggested hardware or other types of devices, that can be used to prevent unauthorized physical access to the IoT device. Providing descriptions of the physical access security procedures the manufacturer recommends for limiting physical access to the device and to associated device controls. Providing details of indications, and recommendations for how to determine, when unauthorized physical access to the IoT device was or is attempted or is occurring. Providing education for how to implement malicious code protection in the IoT device and associated systems as well as how to detect and eradicate malicious code.

197

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

Test Case Identification (ID) and Description with Relevant Cybersecurity Framework Subcategories

Device Cybersecurity Capabilities

Manufacturer Nontechnical Supporting Capabilities

NIST SP 1800-30B: Securing Telehealth Remote Patient Monitoring Ecosystem

Providing education for how to update the IoT device and related systems malicious code protection mechanisms when new releases are available, in accordance with organizational configuration management policy and procedures. If the IoT device manufacturer provides antimalware for the associated IoT device, or if the IoT device has built-in anti-malware capabilities, the manufacturer should provide education to IoT device customers describing how to use and/or configure malicious code protection mechanisms in IoT devices, supporting anti-malware tools, and related systems. Providing education that include the details necessary to implement management and operational controls for malicious code detection and eradication. Providing appropriate tools, assistance, instructions, or other details describing the capabilities for monitoring the IoT device and/or for the IoT device customer to report actions to the monitoring service of the manufacturer’s supporting entity.

198

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

Test Case Identification (ID) and Description with Relevant Cybersecurity Framework Subcategories

Device Cybersecurity Capabilities

Manufacturer Nontechnical Supporting Capabilities

RPM-10 Data Security: Data in Transit Is Protected Demonstrate the ability to protect data in transit between the patient home and the telehealth platform. PR.DS-2

         

Ability to execute cryptographic mechanisms of appropriate strength and performance. Ability to perform authenticated encryption algorithms. Ability to change keys securely. Ability to store encryption keys securely. Ability to secure data stored in remote storage areas (e.g., cloud, server). Ability to support trusted data exchange with a specified minimum-strength cryptography algorithm. Ability to support data encryption and signing to prevent data from being altered in transit. Ability to utilize one or more capabilities to protect transmitted data from unauthorized access and modification. Ability to use cryptographic means to validate the integrity of data transmitted. Ability to protect the audit information through: o encryption o digitally signing audit files o securely sending audit files to another device

NIST SP 1800-30B: Securing Telehealth Remote Patient Monitoring Ecosystem

Providing documentation describing details necessary to identify unauthorized use of IoT devices and their associated systems. Providing documentation that describes indicators of unauthorized use of the IoT device. Providing documentation and/or other communications describing how to implement management and operational controls to protect data obtained from IoT devices and associated systems from unauthorized access, modification, and deletion. Providing education describing how to securely handle and retain IoT device data, associated systems data, and data output from the IoT device to meet requirements of the IoT device customers’ organizational security policies, contractual requirements, applicable Federal laws, Executive Orders, directives, policies, regulations, standards, and other legal requirements.

199

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

Test Case Identification (ID) and Description with Relevant Cybersecurity Framework Subcategories

Device Cybersecurity Capabilities

o

Manufacturer Nontechnical Supporting Capabilities

other protections created by the device manufacturer

NIST SP 1800-30B: Securing Telehealth Remote Patient Monitoring Ecosystem

200

Appendix F Applying the OSI Model in Understanding Zero Trust Architecture

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

Networking professionals often refer to the Open Systems Interconnection (OSI) model when implementing network protocols. The International Organization for Standardization and International Electrotechnical Commission (ISO/IEC) describe the OSI model as consisting of seven layers called Application, Presentation, Session, Transport, Network, Data Link, and Physical, where layers are numerically ordered in reverse. That is, the Application Layer is regarded as Layer 7, whereas the Physical Layer is regarded as Layer 1 [39]. Layer 2 aligns with the OSI model’s Data link layer. Devices operating at Layer 2 have media access control (MAC) addresses by which devices, such as biometric devices, may communicate across a local area network (LAN) segment. Layer 3 aligns with the OSI model’s Network layer. Devices implement the Network layer with Internet Protocol (IP) addresses. Layer 2 over Layer 3 solutions enable devices that do not implement the Network layer to have broader interconnectivity. Layer 2 over Layer 3 solutions provide security by limiting access to devices and securing the data-in-transit communications, e.g., with encryption. Layer 2 over Layer 3 solutions may be used to create secure enclaves, grouping small numbers of devices that may require enhanced network security. Creating secure enclaves aligns with the concept of micro-segmentation. Organizations may consider Layer 2 over Layer 3 solutions for devices that may be prone to internet threats. Biometric devices may implement Layer 2 and Layer 3 interconnectivity; however, they do not have robust controls that prevent unauthorized remote access. Secure enclaves may be created that encapsulate biometric devices with other devices when secure cross communication is required. This practice guide deployed a Layer 2 over Layer 3 solution as part of a proof of concept within the healthcare lab. National Institute of Standards and Technology (NIST) Special Publication (SP) 800-207, Zero Trust Architecture [22], describes an enclave gateway model that may be applied to a telehealth remote patient monitoring (RPM) architecture. In the enclave gateway model, a zero-trust solution operates in two conceptual planes: a control and a data plane. Micro-segmentation management devices operate in a control plane. These management devices provide administrative and policy capabilities to support secure enclaves. Operational components, such as biometric devices, telehealth platform provider services, and devices hosted by healthcare delivery organizations, may operate in the data plane. Figure F-1 depicts the enclave gateway model.

NIST SP 1800-30B: Securing Telehealth Remote Patient Monitoring Ecosystem

201

Figure F-1 Enclave Gateway Model [25]

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

The Layer 2 over Layer 3 solution used in this practice guide brings principles on zero trust architecture (ZTA) to telehealth RPM. Managed biometric devices may be subject to threats that may be present in the patient home network. The Layer 2 over Layer 3 approach segments the RPM components from other devices that may operate in the patient home. Devices not associated with the deployed RPM components do not have a communication pathway to the RPM devices. ZTA allows the biometric devices to authenticate into the Layer 2 over Layer 3 security solution so that only traffic from the RPM components traverses the Layer 2 over Layer 3 network. Practitioners should refer to NIST SP 800-207, Zero Trust Architecture, for guidance [22].

NIST SP 1800-30B: Securing Telehealth Remote Patient Monitoring Ecosystem

202

NIST SPECIAL PUBLICATION 1800-30C

Securing Telehealth Remote Patient Monitoring Ecosystem Volume C: How-To Guides

Jennifer Cawthra* Nakia Grayson Ronald Pulivarti

National Cybersecurity Center of Excellence National Institute of Standards and Technology

Bronwyn Hodges Jason Kuruvilla* Kevin Littlefield Sue Wang Ryan Williams* Kangmin Zheng

The MITRE Corporation McLean, Virginia *Former employee; all work for this publication done while at employer.

February 2022 FINAL This publication is available free of charge from https://doi.org/10.6028/NIST.SP.1800-30 The second draft of this publication is available free of charge from: https://www.nccoe.nist.gov/sites/default/files/legacy-files/rpm-nist-sp1800-30-2nd-draft.pdf

NATIONAL CYBERSECURITY CENTER OF EXCELLENCE

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

The National Cybersecurity Center of Excellence (NCCoE), a part of the National Institute of Standards and Technology (NIST), is a collaborative hub where industry organizations, government agencies, and academic institutions work together to address businesses’ most pressing cybersecurity issues. This public-private partnership enables the creation of practical cybersecurity solutions for specific industries, as well as for broad, cross-sector technology challenges. Through consortia under Cooperative Research and Development Agreements (CRADAs), including technology partners—from Fortune 50 market leaders to smaller companies specializing in information technology security—the NCCoE applies standards and best practices to develop modular, adaptable example cybersecurity solutions using commercially available technology. The NCCoE documents these example solutions in the NIST Special Publication 1800 series, which maps capabilities to the NIST Cybersecurity Framework and details the steps needed for another entity to re-create the example solution. The NCCoE was established in 2012 by NIST in partnership with the State of Maryland and Montgomery County, Maryland. To learn more about the NCCoE, visit https://www.nccoe.nist.gov/. To learn more about NIST, visit https://www.nist.gov.

NIST CYBERSECURITY PRACTICE GUIDES NIST Cybersecurity Practice Guides (Special Publication 1800 series) target specific cybersecurity challenges in the public and private sectors. They are practical, user-friendly guides that facilitate the adoption of standards-based approaches to cybersecurity. They show members of the information security community how to implement example solutions that help them align with relevant standards and best practices and provide users with the lists of materials, configuration files, and other information they need to implement a similar approach. The documents in this series describe example implementations of cybersecurity practices that businesses and other organizations may voluntarily adopt. These documents do not describe regulations or mandatory practices, nor do they carry statutory authority.

ABSTRACT Increasingly, healthcare delivery organizations (HDOs) are relying on telehealth and remote patient monitoring (RPM) capabilities to treat patients at home. RPM is convenient and cost-effective, and its adoption rate has increased. However, without adequate privacy and cybersecurity measures, unauthorized individuals may expose sensitive data or disrupt patient monitoring services. RPM solutions engage multiple actors as participants in a patient’s clinical care. These actors include HDOs, telehealth platform providers, and the patients themselves. Each participant uses, manages, and maintains different technology components within an interconnected ecosystem, and each is

NIST SP 1800-30C: Securing Telehealth Remote Patient Monitoring Ecosystem

iii

responsible for safeguarding their piece against unique threats and risks associated with RPM technologies.

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

This practice guide assumes that the HDO engages with a telehealth platform provider that is a separate entity from the HDO and patient. The telehealth platform provider manages a distinct infrastructure, applications, and set of services. The telehealth platform provider coordinates with the HDO to provision, configure, and deploy the RPM components to the patient home and assures secure communication between the patient and clinician. The NCCoE analyzed risk factors regarding an RPM ecosystem by using risk assessment based on the NIST Risk Management Framework. The NCCoE also leveraged the NIST Cybersecurity Framework, NIST Privacy Framework, and other relevant standards to identify measures to safeguard the ecosystem. In collaboration with healthcare, technology, and telehealth partners, the NCCoE built an RPM ecosystem in a laboratory environment to explore methods to improve the cybersecurity of an RPM. Technology solutions alone may not be sufficient to maintain privacy and security controls on external environments. This practice guide notes the application of people, process, and technology as necessary to implement a holistic risk mitigation strategy. This practice guide’s capabilities include helping organizations assure the confidentiality, integrity, and availability of an RPM solution, enhancing patient privacy and limiting HDO risk when implementing an RPM solution.

KEYWORDS access control; authentication; authorization; behavioral analytics; cloud storage; data privacy; data security; encryption; HDO; healthcare; healthcare delivery organization; remote patient monitoring; RPM; telehealth

ACKNOWLEDGMENTS We are grateful to the following individuals for their generous contributions of expertise and time. Name

Organization

Alex Mohseni

Accuhealth

Stephen Samson

Accuhealth

Brian Butler

Cisco

NIST SP 1800-30C: Securing Telehealth Remote Patient Monitoring Ecosystem

iv

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

Name

Organization

Matthew Hyatt

Cisco

Kevin McFadden

Cisco

Peter Romness

Cisco

Steven Dean

Inova Health System

Zach Furness

Inova Health System

James Carder

LogRhythm

Brian Coulson

LogRhythm

Steven Forsyth

LogRhythm

Jake Haldeman

LogRhythm

Andrew Hollister

LogRhythm

Zack Hollister

LogRhythm

Dan Kaiser

LogRhythm

Sally Vincent

LogRhythm

Vidya Murthy

MedCrypt

Axel Wirth

MedCrypt

Stephanie Domas

MedSec

Garrett Sipple

MedSec

Nancy Correll

The MITRE Corporation

NIST SP 1800-30C: Securing Telehealth Remote Patient Monitoring Ecosystem

v

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

Name

Organization

Spike Dog

The MITRE Corporation

Robin Drake

The MITRE Corporation

Sallie Edwards

The MITRE Corporation

Donald Faatz

The MITRE Corporation

Nedu Irrechukwu

The MITRE Corporation

Karri Meldorf

The MITRE Corporation

Stuart Shapiro

The MITRE Corporation

John Dwyier

Onclave Networks, Inc. (Onclave)

Chris Grodzickyj

Onclave

Marianne Meins

Onclave

Dennis Perry

Onclave

Christina Phillips

Onclave

Robert Schwendinger

Onclave

James Taylor

Onclave

Chris Jensen

Tenable

Joshua Moll

Tenable

Jeremiah Stallcup

Tenable

Julio C. Cespedes

The University of Mississippi Medical Center

NIST SP 1800-30C: Securing Telehealth Remote Patient Monitoring Ecosystem

vi

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

Name

Organization

Saurabh Chandra

The University of Mississippi Medical Center

Donald Clark

The University of Mississippi Medical Center

Alan Jones

The University of Mississippi Medical Center

Kristy Simms

The University of Mississippi Medical Center

Richard Summers

The University of Mississippi Medical Center

Steve Waite

The University of Mississippi Medical Center

Dele Atunrase

Vivify Health

Aaron Gatz

Vivify Health

Michael Hawkins

Vivify Health

Robin Hill

Vivify Health

Dennis Leonard

Vivify Health

David Norman

Vivify Health

Bill Paschall

Vivify Health

Eric Rock

Vivify Health

Alan Stryker

Vivify Health

Dave Sutherland

Vivify Health

Michael Tayler

Vivify Health

NIST SP 1800-30C: Securing Telehealth Remote Patient Monitoring Ecosystem

vii

The Technology Partners/Collaborators who participated in this build submitted their capabilities in response to a notice in the Federal Register. Respondents with relevant capabilities or product components were invited to sign a Cooperative Research and Development Agreement (CRADA) with NIST, allowing them to participate in a consortium to build this example solution. We worked with:

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

Technology Partner/Collaborator

Build Involvement

Accuhealth

Accuhealth Evelyn

Cisco

Cisco Firepower Version 6.3.0 Cisco Umbrella Cisco Stealthwatch Version 7.0.0

Inova Health System

subject matter expertise

LogRhythm

LogRhythm XDR Version 7.4.9 LogRhythm NetworkXDR Version 4.0.2

MedCrypt

subject matter expertise

MedSec

subject matter expertise

Onclave Networks, Inc. (Onclave)

Onclave Zero Trust Platform Version 1.1.0

Tenable

Tenable.sc Vulnerability Management Version 5.13.0 with Nessus

The University of Mississippi Medical Center

subject matter expertise

Vivify Health

Vivify Pathways Home Vivify Pathways Care Team Portal

NIST SP 1800-30C: Securing Telehealth Remote Patient Monitoring Ecosystem

viii

DOCUMENT CONVENTIONS

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

The terms “shall” and “shall not” indicate requirements to be followed strictly to conform to the publication and from which no deviation is permitted. The terms “should” and “should not” indicate that among several possibilities, one is recommended as particularly suitable without mentioning or excluding others, or that a certain course of action is preferred but not necessarily required, or that (in the negative form) a certain possibility or course of action is discouraged but not prohibited. The terms “may” and “need not” indicate a course of action permissible within the limits of the publication. The terms “can” and “cannot” indicate a possibility and capability, whether material, physical, or causal.

PATENT DISCLOSURE NOTICE NOTICE: The Information Technology Laboratory (ITL) has requested that holders of patent claims whose use may be required for compliance with the guidance or requirements of this publication disclose such patent claims to ITL. However, holders of patents are not obligated to respond to ITL calls for patents and ITL has not undertaken a patent search in order to identify which, if any, patents may apply to this publication. As of the date of publication and following call(s) for the identification of patent claims whose use may be required for compliance with the guidance or requirements of this publication, no such patent claims have been identified to ITL. No representation is made or implied by ITL that licenses are not required to avoid patent infringement in the use of this publication.

NIST SP 1800-30C: Securing Telehealth Remote Patient Monitoring Ecosystem

ix

Contents 1 Introduction ...................................................................................... 11

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

1.1

How-To Guide .............................................................................................................. 11

1.2

Build Overview ............................................................................................................ 12

1.3

Typographic Conventions ............................................................................................ 13

1.4

Logical Architecture Summary .................................................................................... 13

2 Product Installation Guide ................................................................ 14 2.1

2.2

Telehealth Platform Provider ...................................................................................... 15 2.1.1

Accuhealth .................................................................................................................. 16

2.1.2

Vivify ........................................................................................................................... 20

Security Capabilities .................................................................................................... 24 2.2.1

Risk Assessment Controls ........................................................................................... 24

2.2.2

Identity Management, Authentication, and Access Control ......................................42

2.2.3

Security Continuous Monitoring ................................................................................. 85

2.2.4

Cisco Stealthwatch ...................................................................................................... 86

2.2.5

Data Security ............................................................................................................. 153

Appendix A List of Acronyms ............................................................... 170 Appendix B References ....................................................................... 171

List of Figures Figure 1-1 Final Architecture .............................................................................................................. 14 Figure 2-1 RPM Communications Paths .............................................................................................. 16

NIST SP 1800-30C: Securing Telehealth Remote Patient Monitoring Ecosystem

x

1 Introduction

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

The following volumes of this guide show information technology (IT) professionals and security engineers how we implemented this example solution. We cover all of the products employed in this reference design. We do not recreate the product manufacturers’ documentation, which is presumed to be widely available. Rather, these volumes show how we incorporated the products together in our environment. Note: These are not comprehensive tutorials. There are many possible service and security configurations for these products that are out of scope for this reference design.

1.1 How-To Guide This National Institute of Standards and Technology (NIST) Cybersecurity Practice Guide demonstrates a standards-based reference design and provides users with the information they need to replicate the telehealth remote patient monitoring (RPM) environment. This reference design is modular and can be deployed in whole or in part. This guide contains three volumes: 

NIST SP 1800-30A: Executive Summary

NIST SP 1800-30B: Approach, Architecture, and Security Characteristics–what we built and why

NIST SP 1800-30C: How-To Guides–instructions for building the example solution (you are here)

Depending on your role in your organization, you might use this guide in different ways: Business decision makers, including chief security and technology officers, will be interested in the Executive Summary, NIST SP 1800-30A, which describes the following topics: 

challenges that enterprises face in securing the remote patient monitoring ecosystem

example solution built at the NCCoE

benefits of adopting the example solution

Technology or security program managers who are concerned with how to identify, understand, assess, and mitigate risk will be interested in NIST SP 1800-30B, which describes what we did and why. The following sections will be of particular interest: 

Section 3.4, Risk Assessment, describes the risk analysis we performed.

Section 3.5, Security Control Map, maps the security characteristics of this example solution to cybersecurity standards and best practices.

NIST SP 1800-30C: Securing Telehealth Remote Patient Monitoring Ecosystem

11

You might share the Executive Summary, NIST SP 1800-30A, with your leadership team members to help them understand the importance of adopting standards-based commercially available technologies that can help secure the RPM ecosystem.

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

IT professionals who want to implement an approach like this will find this whole practice guide useful. You can use this How-To portion of the guide, NIST SP 1800-30C, to replicate all or parts of the build created in our lab. This How-To portion of the guide provides specific product installation, configuration, and integration instructions for implementing the example solution. We do not recreate the product manufacturers’ documentation, which is generally widely available. Rather, we show how we incorporated the products together in our environment to create an example solution. This guide assumes that IT professionals have experience implementing security products within the enterprise. While we have used a suite of commercial products to address this challenge, this guide does not endorse these particular products. Your organization can adopt this solution or one that adheres to these guidelines in whole, or you can use this guide as a starting point for tailoring and implementing parts of the National Cybersecurity Center of Excellences’ (NCCoE’s) risk assessment and deployment of a defense-in-depth strategy in a distributed RPM solution. Your organization’s security experts should identify the products that will best integrate with your existing tools and IT system infrastructure. We hope that you will seek products that are congruent with applicable standards and best practices. Section 3.6, Technologies, lists the products that we used and maps them to the cybersecurity controls provided by this reference solution. A NIST Cybersecurity Practice Guide does not describe “the” solution but a possible solution. We seek feedback on its contents and welcome your input. Comments, suggestions, and success stories will improve subsequent versions of this guide. Please contribute your thoughts to hit_nccoe@nist.gov. Acronyms used in figures are in the List of Acronyms appendix.

1.2 Build Overview The NCCoE constructed a virtual lab environment to evaluate ways to implement security capabilities across an RPM ecosystem, which consists of three separate domains: patient home, telehealth platform provider, and healthcare delivery organization (HDO). The project implements virtual environments for the HDO and patient home while collaborating with a telehealth platform provider to implement a cloud-based telehealth RPM environment. The telehealth environments contain simulated patient data that portray relevant cases that clinicians could encounter in real-world scenarios. The project then applies security controls to the virtual environments. Refer to NIST Special Publication (SP) 1800-30B, Section 5, Security Characteristic Analysis, for an explanation of why we used each technology.

NIST SP 1800-30C: Securing Telehealth Remote Patient Monitoring Ecosystem

12

1.3 Typographic Conventions The following table presents typographic conventions used in this volume.

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

Typeface/Symbol

Meaning

Example

Italics

file names and path names; references to documents that are not hyperlinks; new terms; and placeholders names of menus, options, command buttons, and fields command-line input, onscreen computer output, sample code examples, and status codes command-line user input contrasted with computer output link to other parts of the document, a web URL, or an email address

For language use and style guidance, see the NCCoE Style Guide.

Bold Monospace

Monospace Bold

blue text

Choose File > Edit. mkdir

service sshd start

All publications from NIST’s NCCoE are available at https://www.nccoe.nist.gov.

1.4 Logical Architecture Summary Figure 1-1 illustrates the reference network architecture implemented in the NCCoE virtual environment, initially presented in NIST SP 1800-30B, Section 4.5, Final Architecture. The HDO environment utilizes network segmenting similar to the architecture segmentation used in NIST SP 180024, Securing Picture Archiving and Communication System (PACS) [1]. The telehealth platform provider is a vendor-managed cloud environment that facilitates data transmissions and communications between the patient home and the HDO. Patient home environments have a minimalistic structure, which incorporates the devices provided by the telehealth platform provider.

NIST SP 1800-30C: Securing Telehealth Remote Patient Monitoring Ecosystem

13

Figure 1-1 Final Architecture

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

2 Product Installation Guide This section of the practice guide contains detailed instructions for installing and configuring all the products used to build an instance of the example solution. The project team implemented several capabilities that included deploying components received from telehealth platform providers and components that represent the HDO. The telehealth platform providers provisioned biometric devices that were deployed to a patient home environment. Within the HDO, the engineers deployed network infrastructure devices to implement network zoning and configure perimeter devices. The engineers also deployed security capabilities that supported vulnerability management and a security incident and event management (SIEM) tool. The following sections detail deployment and configuration of these components.

NIST SP 1800-30C: Securing Telehealth Remote Patient Monitoring Ecosystem

14

2.1 Telehealth Platform Provider

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

The project team implemented a model where an HDO partners with telehealth platform providers to enable RPM programs. Telehealth platform providers are third parties that, for this practice guide, configured, deployed, and managed biometric devices and mobile devices (e.g., tablets) that were sent to the patient home. The telehealth platform provider managed data communications over cellular and broadband where patients send biometric data to the telehealth platform provider. The telehealth platform provider implemented an application that allowed clinicians to access the biometric data. The team collaborated with two independent telehealth platform providers. Collaborating with two unique platforms enabled the team to apply NIST’s Cybersecurity Framework [2] to multiple telehealth platform implementations. One platform provides biomedical devices enabled with cellular data. These devices transmitted biometric data to the cloud-based telehealth platform. The second platform provider deployed biometric devices enabled with Bluetooth wireless technology. Biometric devices communicated with an interface device (i.e., a tablet). The telehealth platform provider configured the interface device by using a mobile device management solution, limiting the interface device’s capabilities to those services required for RPM participation. The patient transmitted biometric data to the telehealth platform provider by using the interface device. The interface device transmitted data over cellular or broadband data communications. Both telehealth platform providers allowed HDOs to access patient data by using a web-based application. Both platforms implemented unique access control policies for access control, authentication, and authorization. Figure 2-1 depicts the different communication pathways tested in this practice guide. A detailed description of each communications pathway is provided in NIST SP 1800-30B, Section 4.2, High-Level Architecture Communications Pathways.

NIST SP 1800-30C: Securing Telehealth Remote Patient Monitoring Ecosystem

15

Figure 2-1 RPM Communications Paths

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

2.1.1 Accuhealth Accuhealth provided biometric devices that included cellular data communication. Accuhealth also included a cloud-hosted application for HDOs to access patient-sent biometric data. Accuhealth provisioned biomedical devices with subscriber identity module (SIM) cards that enabled biomedical devices to transmit data via cellular data communications to the Accuhealth telehealth platform. Accuhealth stored patient-transmitted data in an application. Individuals assigned with clinician roles accessed transmitted data hosted in the Accuhealth application. The biomedical data displayed in the following screen captures are notional in nature and do not relate to an actual patient.

2.1.1.1 Patient Home–Communication Path A 14B

This practice guide assumes that the HDO enrolls the patient in an RPM program. Clinicians would determine when a patient may be enrolled in the program appropriately, and conversations would occur about understanding the roles and responsibilities associated with participating in the RPM program. When clinicians enroll patients in the RPM program, the HDO would collaborate with Accuhealth.

NIST SP 1800-30C: Securing Telehealth Remote Patient Monitoring Ecosystem

16

Accuhealth received patient contact information and configured biometric devices appropriate for the RPM program in which the patient was enrolled. Accuhealth configured biometric devices to communicate via cellular data, which is depicted as communication path A of Figure 2-1. Biometric devices. Thus, biometric devices were isolated from the patient home network environment.

2.1.1.2 HDO 15B

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

The Accuhealth solution includes installing an application within the HDO environment. Clinicians access a portal hosted by Accuhealth that allows a clinician to view patient biometric data. The application requires unique user accounts and role-based access control. System administrators create accounts and assign roles through an administrative console. Sessions from the clinician to the hosted application use encryption to ensure data-in-transit protection. This section discusses the HDO application installation and configuration procedures. 1. Access a device that has a web browser. 2. Navigate to Accuhealth login page and provide a Username and Password. The following screenshots show a doctor’s point of view in the platform. 3. Click LOG IN.

After logging in, the Patient Overview screen displays.

NIST SP 1800-30C: Securing Telehealth Remote Patient Monitoring Ecosystem

17

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

4. To view patients associated with the account used to log in, navigate to the View Select dropdown list in the top left corner of the screen and select My Patients.

5. Click a Patient to display the Patient Details page, which displays all patient biomedical readings.

NIST SP 1800-30C: Securing Telehealth Remote Patient Monitoring Ecosystem

18

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

6. To leave a comment on a reading, click no comments yet under the Comments column on the row of the reading to which the comment refers. 7. A Comment screen displays that allows free text input. 8. Click Comment. 9. Click Close.

NIST SP 1800-30C: Securing Telehealth Remote Patient Monitoring Ecosystem

19

10. To have a call with a patient, click Request an Appointment in the top left of the Patient Details page. 11. A notification box displays, asking if the Home Health Agency needs to schedule an appointment with the patient. 12. Click OK. This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

2.1.2 Vivify Vivify provided biometric and interface devices (i.e., Vivify provisioned a tablet device) and a cloudhosted platform. Vivify enabled biometric devices with Bluetooth communication and provisioned interface devices with SIM cards. Individuals provisioned with patient roles used the interface device to retrieve data from the biometric devices via Bluetooth. Individuals acting as patients then used the interface device to transmit data to Vivify by using cellular data. Vivify’s application presented the received data. Individuals provisioned with clinician roles accessed the patient-sent data stored in the Vivify application via a web interface.

2.1.2.1 Patient Home–Communication Path B This practice guide assumes that the HDO enrolls the patient in an RPM program. Clinicians would determine when a patient may be enrolled in the program appropriately, and conversations then occur about understanding the roles and responsibilities associated with participating in the RPM program. When clinicians enroll patients in the RPM program, the HDO would collaborate with Vivify. Vivify received patient contact information and configured biometric devices and an interface device (i.e.,

NIST SP 1800-30C: Securing Telehealth Remote Patient Monitoring Ecosystem

20

tablet) appropriate for the RPM program in which the patient was enrolled. These devices were configured to transmit data via cellular through the interface device, which is depicted as communication path B in Figure 2-1. Vivify assured device configuration and asset management.

2.1.2.2 Patient Home–Communication Paths C and D This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

To evaluate communication path C in Figure 2-1, the project team implemented another instance of the Vivify Pathways Care Team Portal in a simulated cloud environment. The simulated cloud environment represented how a telehealth platform provider may operate; however, it does not reflect how any specific telehealth platform provider hosts its components. The simulated cloud environment deployed Vivify-provided software. One should note that the simulated cloud environment does not represent how Vivify implements its commercial service offering. The NCCoE implemented the simulated cloud environment as a test case where telehealth platforms may incorporate layer 2 over layer 3 solutions as part of their architecture. A Vivify Pathways Home kit was hosted in a patient home network, which included peripherals as well as an RPM interface. Engineers connected the RPM interface (mobile device) to the patient home network to enable broadband communications with the new simulated cloud instance. The RPM interface collected patient data from the provided peripherals via Bluetooth and then transmitted thesedata to the simulated cloud environment through the broadband connection. After implementing communication path C and the Onclave Network Solution, the RPM interface connected to an add-on security control, Onclave Home Gateway, inside the patient home environment. Once the RPM interface was connected to the Onclave Home Gateway, patient data were transmitted to the simulated cloud environment through the Onclave Telehealth Gateway. These connections enabled the project team to implement communication path D as depicted in Figure 2-1. Details on how engineers installed and configured Onclave tools are described in section 2.2.4.1, Onclave SecureIoT.

2.1.2.3 Telehealth Platform Provider–Communication Paths C and D For communication paths C and D, a simulated cloud environment was created to represent a telehealth platform provider that supports broadband-capable biometric devices. A sample Vivify Pathways Care Team Portal was obtained to demonstrate how patient data could be transmitted via broadband communications. Practitioners should note, however, that Vivify as an entity may not support this use case. Vivify engineers facilitated deploying the Vivify Pathways Care Team Portal as representative of how a telehealth platform provider may support the communications pathway. Communication paths A and B used telehealth platform providers that were located outside the NCCoE lab, and data were transmitted via cellular communications. Communication path D required more add-on security controls to be configured in the virtual cloud environment. For this communication pathway, the representative Vivify Pathways Care Team Portal was connected to an Onclave Telehealth Gateway. This gateway accepted data transmissions from the RPM interface connected to the Onclave Home Gateway housed in the patient home environment.

NIST SP 1800-30C: Securing Telehealth Remote Patient Monitoring Ecosystem

21

2.1.2.4 HDO Using a web browser interface, clinicians access a portal hosted by Vivify that allows access to view patient biometric data. Portal interaction requires unique user accounts and role-based access control. System administrators create accounts and assign roles through an administrative console. Sessions from the clinician to the hosted application use encryption to ensure data-in-transit protection. This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

This section discusses the HDO application installation and configuration procedures. 1. Access a device that has a web browser. 2. Navigate to https://<vivifyhealth site>/CaregiverPortal/Login and give the Username and Password of the administrative account provided by Vivify. 3. Click Login.

4. Navigate to the Care Team menu item on the left-hand side of the screen. Click + New User. 5. In the New User screen, provide the following information: a. First Name: Test

NIST SP 1800-30C: Securing Telehealth Remote Patient Monitoring Ecosystem

22

b. Last Name: Clinician c. User Name: TClinician1 d. Password: ********** e. Confirm Password: ********** This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

f.

Facilities: Vivify General

g. Sites: Default h. Roles: Clinical Level 1, Clinical Level 2 i.

Email Address: **********

j.

Mobile Phone: *********

6. Click Save Changes. 7. Navigate to Patients in the left-hand menu bar. 8. Select the NCCoE, Patient record. 9. Under Care Team, click the notepad and pencil in the top right of the box. 10. In the Care Team window, select Clinician, Test and click Ok. 11. Log out of the platform. 12. Log in to the platform by using the Test Clinician credentials and click Login. 13. Click the NCCoE, Patient record. 14. Navigate to the Monitoring tab to review patient readings. 15. Based on the patient’s data, the clinician needs to consult the patient. 16. Click the ellipsis in the NCCoE, Patient menu above the green counter. 17. Select Call Patient. 18. In the Respond to Call Request screen, select Phone Call Now. 19. After the consultation, record the action items performed during the call. 20. In the Monitoring window, click Accept All under the Alerts tab to record intervention steps. 21. In the Select Intervention window, select the steps performed to address any patient alerts. 22. Click Accept.

NIST SP 1800-30C: Securing Telehealth Remote Patient Monitoring Ecosystem

23

23. Navigate to Notes to review recorded interventions or add other clinical notes

2.2 Security Capabilities The following instruction and configuration steps depict how the NCCoE engineers and project collaborators implemented the provided cybersecurity tools to achieve the desired security capabilities identified in NIST SP 1800-30B, Section 4.4, Security Capabilities. This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

2.2.1 Risk Assessment Controls Risk assessment controls align with the NIST Cybersecurity Framework’s ID.RA category. For this practice guide, the Tenable.sc solution was implemented as a component in an HDO’s risk assessment program. While Tenable.sc includes a broad functionality set, the project team leveraged Tenable.sc’s vulnerability scanning and management capabilities.

2.2.1.1 Tenable.sc Tenable.sc is a vulnerability management solution. Tenable.sc provides a dashboard graphic user interface that displays the results from its vulnerability scanning and configuration scanning capabilities. Tenable.sc’s dashboard includes vulnerability scoring, enabling engineers to prioritize patching and remediation. The engineers used Tenable.sc to manage a Nessus scanner, which performed vulnerability scanning against HDO domain-hosted devices. While the Tenable.sc solution includes configurationchecking functionality, this practice guide uses the solution for vulnerability management. System Requirements Central Processing Unit (CPU): 4 Memory: 8 gigabytes (GB) Storage: 250 GB Operating System: CentOS 7 Network Adapter: virtual local area network (VLAN) 1348 Tenable.sc Installation This section discusses installation of the Tenable.sc vulnerability management solution. 1. Import the Tenable.sc open virtual appliance or appliance (OVA) file to the virtual environment. 2. Assign the virtual machine (VM) to VLAN 1348. 3. Start the VM and document the associated internet protocol (IP) address. 4. Open a web browser that can talk to VLAN 1348 and navigate to the VM’s IP address.

NIST SP 1800-30C: Securing Telehealth Remote Patient Monitoring Ecosystem

24

5. For the first login, use wizard as the Username and admin for the Password. 6. Tenable.sc prompts a pop-up window for creating a new admin username and password. 7. Repeat step 5 using the new username and password. a. Username: admin This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

b. Password: ********** c. Check the box beside Reuse my password for privileged tasks.

8. After logging in, the Tenable Management Console page displays. 9. Click the Tenable.sc menu option on the left side of the screen. 10. To access Tenable.sc, click the IP address next to the uniform resource locator (URL) field.

NIST SP 1800-30C: Securing Telehealth Remote Patient Monitoring Ecosystem

25

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

11. Log in to Tenable.sc by using the credentials created in previous steps and click Sign In. a. Username: admin b. Password: **********

NIST SP 1800-30C: Securing Telehealth Remote Patient Monitoring Ecosystem

26

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

12. After signing in, Tenable.sc’s web page displays. 13. Navigate to the System drop-down list in the menu ribbon. 14. Click Configuration. 15. Under Tenable.sc License, click Upload next to License File. 16. Navigate to the storage location of the Tenable.sc license key obtained from a Tenable representative and select the key file. 17. Click OK. 18. Click Validate. 19. When Tenable.sc accepts the key, a green Valid label will display next to License File.

NIST SP 1800-30C: Securing Telehealth Remote Patient Monitoring Ecosystem

27

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

20. Under Additional Licenses, input the Nessus license key provided by a Tenable representative next to Nessus Scanner. 21. Click Register.

NIST SP 1800-30C: Securing Telehealth Remote Patient Monitoring Ecosystem

28

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

Tenable.sc Configuration The project team leveraged support from Tenable engineers. Collectively, engineers installed Tenable.sc and validated license keys for Tenable.sc and Nessus. Engineers created Organization, Repository, User, Scanner, and Scan Zones instances for the HDO lab environment. The configuration steps are below. Add an Organization 1. Navigate to Organizations in the menu ribbon. 2. Click +Add in the top right corner of the screen. An Add Organization page will appear. 3. Name the Organization RPM HDO and leave the remaining fields as their default values. 4. Click Submit.

NIST SP 1800-30C: Securing Telehealth Remote Patient Monitoring Ecosystem

29

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

Add a Repository 1. Navigate to the Repositories drop-down list in the menu ribbon. 2. Click +Add in the top right corner of the screen. An Add Repository screen displays. 3. Under Local, click IPv4. An Add IPv4 Repository page displays. Provide the following information: a. Name: HDO Repository b. IP Ranges: 0.0.0.0/24 c. Organizations: RPM HDO 4. Click Submit.

NIST SP 1800-30C: Securing Telehealth Remote Patient Monitoring Ecosystem

30

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

Add a User 1. Navigate to the Users drop-down list in the menu ribbon. 2. Select Users. 3. Click +Add in the top right corner. An Add User page displays. Provide the following information: a. Role: Security Manager b. Organization: RPM HDO

NIST SP 1800-30C: Securing Telehealth Remote Patient Monitoring Ecosystem

31

c. First Name: Test d. Last Name: User e. Username: TestSecManager f.

Password: **********

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

g. Confirm Password: ********** h. Enable User Must Change Password. i.

Time Zone: America/New York

4. Click Submit.

NIST SP 1800-30C: Securing Telehealth Remote Patient Monitoring Ecosystem

32

For the lab deployment of Tenable.sc, the engineers instantiated one Nessus scanner in the Security Services subnet that has access to every subnet in the HDO environment. Add a Scanner 1. Navigate to the Resources drop-down list in the menu ribbon. 2. Select Nessus Scanners. This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

3. Click +Add in the top right corner. An Add Nessus Scanner page displays. Fill in the following information: a. Name: HDO Scanner b. Description: Scans the Workstation, Enterprise, HIS, Remote, and Database VLANs c. Host: 192.168.45.100 d. Port: 8834 e. Enabled: on f.

Type: Password

g. Username: TestSecManager h. Password: ********** 4. Click Submit.

NIST SP 1800-30C: Securing Telehealth Remote Patient Monitoring Ecosystem

33

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

The engineers created a scan zone for each subnet established on the HDO network. The process to create a scan zone is the same for each subnet aside from the IP address range. As an example, the steps for creating the Workstation scan zone are as follows: Add a Scan Zone 1. Navigate to the Resources drop-down list in the menu ribbon. 2. Select Scan Zones.

NIST SP 1800-30C: Securing Telehealth Remote Patient Monitoring Ecosystem

34

3. Click +Add. An Add Scan Zone page will appear. Provide the following information: a. Name: Workstations b. Ranges: 192.168.44.0/24 c. Scanners: HDO Scanner This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

4. Click Submit.

Repeat steps in Add a Scan Zone section for each VLAN. To fulfil the identified NIST Cybersecurity Framework Subcategory requirements, the engineers utilized Tenable’s host discovery and vulnerability scanning capabilities. The first goal was to identify the hosts

NIST SP 1800-30C: Securing Telehealth Remote Patient Monitoring Ecosystem

35

on each of the HDO VLANs. Once Tenable identifies the assets, Tenable.sc executes a basic network scan to identify any vulnerabilities on these assets. Create Scan Policies 1. Engineers created a Security Manager account in a previous step when adding users. Log in to Tenable.sc by using the Security Manager account. This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

2. Navigate to the Scans drop-down list in the menu ribbon. 3. Select Policies. 4. Click +Add in the top right corner. 5. Click Host Discovery in the Add Policy page. An Add Policy > Host Discovery page will appear. Provide the following information: a. Name: HDO Assets b. Discovery: Host enumeration c. Leave the remaining options as their default values. 6. Click Submit.

NIST SP 1800-30C: Securing Telehealth Remote Patient Monitoring Ecosystem

36

7. Click +Add in the top right corner. 8. Click Basic Network Scan in the Add Policy page. An Add Policy > Basic Network Scan page displays. 9. Name the scan HDO Network Scan and leave the remaining options to their default settings. 10. Click Submit. This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

Create Active Scans 1. Navigate to the Scans drop-down list in the menu ribbon. 2. Select Active Scans. 3. Click +Add in the top right corner. An Add Active Scan page will appear. Provide the following information for General and Target Type sections. General a. Name: Asset Scan b. Description: Identify hosts on the VLANs c. Policy: Host Discovery Targets a. Target Type: IP/DNS Name

NIST SP 1800-30C: Securing Telehealth Remote Patient Monitoring Ecosystem

37

b. IPs/DNS Names: 192.168.44.0/24, 192.168.40.0/24, 192.168.41.0/24, 192.168.42.0/24, 192.168.43.0/24 4. Click Submit.

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30. NIST SP 1800-30C: Securing Telehealth Remote Patient Monitoring Ecosystem

38

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

Repeat steps in Create Active Scans section for the Basic Network Scan policy. Keep the same value as defined for Active Scan except the following: a. Name the scan HDO Network Scan. b. Set Policy to HDO Network Scan. After the engineers created and correlated the Policies and Active Scans to each other, they executed the scans. Execute Active Scans 1. Navigate to the Scans drop-down list in the menu ribbon. 2. Select Active Scans. 3. Next to HDO Asset Scan click . 4. Navigate to the Scan Results menu option shown at the top of the screen under the menu ribbon to see the status of the scan. 5. Click HDO Asset Scan to see the scan results. 6. Repeat the above steps for HDO Network Scan. View Active Scan Results in the Dashboard 1. Navigate to the Dashboard drop-down list in the menu ribbon. 2. Select Dashboard.

NIST SP 1800-30C: Securing Telehealth Remote Patient Monitoring Ecosystem

39

3. In the top right, click Switch Dashboard. 4. Click Vulnerability Overview. A screen will appear that displays a graphical representation of the vulnerability results gathered during the HDO Host Scan and HDO Network Scan.

2.2.1.2 Nessus This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

Nessus is a vulnerability scanning engine that evaluates a host’s operating system and configuration to determine the presence of exploitable vulnerabilities. This project uses one Nessus scanner to scan each VLAN created in the HDO environment to identify hosts and the vulnerabilities associated with those hosts. Nessus sends the results back to Tenable.sc, which graphically represents the results in dashboards. System Requirements CPU: 4 Memory: 8 GB Storage: 82 GB Operating System: CentOS 7 Network Adapter: VLAN 1348 Nessus Installation 1. Import the OVA file to the virtual lab environment. 2. Assign the VM to VLAN 1348. 3. Start the VM and document the associated IP address. 4. Open a web browser that can talk to VLAN 1348 and navigate to the VM’s IP address. 5. Log in using wizard as the Username and admin for the Password. 6. Create a new admin username and password. 7. Log in using the new username and password. a. Username: admin b. Password: ********** c. Enable Reuse my password for privileged tasks.

NIST SP 1800-30C: Securing Telehealth Remote Patient Monitoring Ecosystem

40

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

8. Click Tenable.sc on the left side of the screen. 9. To access Tenable.sc, click the IP address next to the URL field.

NIST SP 1800-30C: Securing Telehealth Remote Patient Monitoring Ecosystem

41

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

Nessus Configuration The engineers utilized Tenable.sc to manage Nessus. To configure Nessus as managed by Tenable.sc, follow Tenable’s Managed by Tenable.sc guide [3].

2.2.2 Identity Management, Authentication, and Access Control Identity management, authentication, and access control align with the NIST Cybersecurity Framework PR.AC category. The engineers implemented capabilities in the HDO to address this control category. First, they implemented Microsoft Active Directory (AD), then installed a domain controller to establish an HDO domain. Next, the engineers implemented Cisco Firepower as part of its network core infrastructure. They used Cisco Firepower to build VLANs that aligned to network zones. Cisco Firepower also was configured to provide other network services. Details on installation are included in the following sections.

2.2.2.1 Domain Controller The engineers installed a Windows Server domain controller within the HDO to manage AD and local domain name system (DNS) for the enterprise. The following section details how the engineers installed the services. Domain Controller Appliance Information

NIST SP 1800-30C: Securing Telehealth Remote Patient Monitoring Ecosystem

42

CPU: 4 Random Access Memory (RAM): 8 GB Storage: 120 GB (Thin Provision) Network Adapter 1: VLAN 1327 This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

Operating System: Microsoft Windows Server 2019 Datacenter Domain Controller Appliance Installation Guide Install the appliance according to the instructions detailed in Microsoft’s Install Active Directory Domain Services (Level 100) documentation [4]. Verify Domain Controller Installation 1. Launch Server Manager. 2. Click Tools > Active Directory Domains and Trusts.

3. Right-click hdo.trpm. 4. Click Manage.

NIST SP 1800-30C: Securing Telehealth Remote Patient Monitoring Ecosystem

43

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

5. Click hdo.trpm > Domain Controllers. 6. Check that the Domain Controllers directory lists the new domain controller.

Configure Local DNS 1. Launch Server Manager. 2. Click Tools > DNS.

NIST SP 1800-30C: Securing Telehealth Remote Patient Monitoring Ecosystem

44

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

3. Click the arrow symbol for DC-HDO. 4. Right-click Reverse Lookup Zones. 5. Click New Zone…. The New Zone Wizard displays.

6. Click Next >.

NIST SP 1800-30C: Securing Telehealth Remote Patient Monitoring Ecosystem

45

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

7. Click Primary zone. 8. Check Store the zone in Active Directory. 9. Click Next >.

NIST SP 1800-30C: Securing Telehealth Remote Patient Monitoring Ecosystem

46

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

10. Check To all DNS servers running on domain controllers in this forest: hdo.trpm. 11. Click Next >.

NIST SP 1800-30C: Securing Telehealth Remote Patient Monitoring Ecosystem

47

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

12. Check IPv4 Reverse Lookup Zone. 13. Click Next >.

NIST SP 1800-30C: Securing Telehealth Remote Patient Monitoring Ecosystem

48

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

14. Check Network ID. 15. Under Network ID, type 192.168. 16. Click Next >.

NIST SP 1800-30C: Securing Telehealth Remote Patient Monitoring Ecosystem

49

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

17. Check Allow only secure dynamic updates. 18. Click Next >.

NIST SP 1800-30C: Securing Telehealth Remote Patient Monitoring Ecosystem

50

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

19. Click Finish.

NIST SP 1800-30C: Securing Telehealth Remote Patient Monitoring Ecosystem

51

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

20. Click the arrow symbol for Reverse Lookup Zones. 21. Right-click 168.192.in-addr.arpa. 22. Click New Pointer (PTR)….

NIST SP 1800-30C: Securing Telehealth Remote Patient Monitoring Ecosystem

52

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

23. Under Host name, click Browse….

NIST SP 1800-30C: Securing Telehealth Remote Patient Monitoring Ecosystem

53

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

24. Under Look in, select hdo.trpm. 25. Under Records, select dc-hdo. 26. Click OK.

NIST SP 1800-30C: Securing Telehealth Remote Patient Monitoring Ecosystem

54

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

27. Click OK.

55

NIST SP 1800-30C: Securing Telehealth Remote Patient Monitoring Ecosystem

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

56

NIST SP 1800-30C: Securing Telehealth Remote Patient Monitoring Ecosystem

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

2.2.2.2 Cisco Firepower Cisco Firepower consists of two primary components: Cisco Firepower Management Center and Cisco Firepower Threat Defense (FTD). Cisco Firepower provides firewall, intrusion prevention, and other networking services. This project used Cisco Firepower to implement VLAN network segmentation, network traffic filtering, internal and external routing, applying an access control policy, and Dynamic Host Configuration Protocol (DHCP). Engineers deployed Cisco Firepower as a core component for the lab’s network infrastructure. Cisco Firepower Management Center (FMC) Appliance Information CPU: 4 RAM: 8 GB Storage: 250 GB (Thick Provision) Network Adapter 1: VLAN 1327 Operating System: Cisco Fire Linux 6.4.0 Cisco Firepower Management Center Installation Guide Install the appliance according to the instructions detailed in the Cisco Firepower Management Center Virtual Getting Started Guide [5]. Cisco FTD Appliance Information CPU: 8

NIST SP 1800-30C: Securing Telehealth Remote Patient Monitoring Ecosystem

57

RAM: 16 GB Storage: 48.5 GB (Thick Provision) Network Adapter 1: VLAN 1327 Network Adapter 2: VLAN 1327 This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

Network Adapter 3: VLAN 1316 Network Adapter 4: VLAN 1327 Network Adapter 5: VLAN 1328 Network Adapter 6: VLAN 1329 Network Adapter 7: VLAN 1330 Network Adapter 8: VLAN 1347 Network Adapter 9: VLAN 1348 Operating System: Cisco Fire Linux 6.4.0 Cisco FTD Installation Guide Install the appliance according to the instructions detailed in the Cisco Firepower Threat Defense Virtual for VMware Getting Started Guide in the Deploy the Firepower Threat Defense Virtual chapter [6]. Configure FMC Management of FTD The Cisco Firepower Threat Defense Virtual for VMware Getting Started Guide’s Managing the Firepower Threat Defense Virtual with the Firepower Management Center (FMC) chapter covers how we registered the FTD appliance with the FMC [7]. Once the FTD successfully registers with the FMC, it will appear under Devices > Device Management in the FMC interface.

NIST SP 1800-30C: Securing Telehealth Remote Patient Monitoring Ecosystem

58

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

From the Device Management section, the default routes, interfaces, and DHCP settings can be configured. To view general information for the FTD appliance, navigate to Devices > Device Management > FTD-TRPM > Device.

NIST SP 1800-30C: Securing Telehealth Remote Patient Monitoring Ecosystem

59

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

Configure Cisco FTD Interfaces for the RPM Architecture By default, each of the interfaces is defined as GigabitEthernet and is denoted as 0 through 6.

NIST SP 1800-30C: Securing Telehealth Remote Patient Monitoring Ecosystem

60

1. From Devices > Device Management > FTD-TRPM > Device, click Interfaces. 2. On the Cisco FTD Interfaces window, an Edit icon appears on the far right. The first GigabitEthernet interface configured is GigabitEthernet0/0. Click the Edit icon to configure the GigabitEthernet interface.

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

3. The Edit Physical Interface group box displays. Under the General tab, enter WAN in the Name field.

NIST SP 1800-30C: Securing Telehealth Remote Patient Monitoring Ecosystem

61

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

4. Under Security Zone, click the drop-down arrow and select New….

NIST SP 1800-30C: Securing Telehealth Remote Patient Monitoring Ecosystem

62

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

5. The New Security Zone pop-up box appears. Enter WAN in the Enter a name… field. 6. Click OK.

NIST SP 1800-30C: Securing Telehealth Remote Patient Monitoring Ecosystem

63

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

7. On the Edit Physical Interface page group box, click the IPv4 tab.

NIST SP 1800-30C: Securing Telehealth Remote Patient Monitoring Ecosystem

64

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

8. Fill out the following information: a. IP Type: Use Static IP b. IP Address: 192.168.4.50/24 c. Click OK.

NIST SP 1800-30C: Securing Telehealth Remote Patient Monitoring Ecosystem

65

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

9. Configure each of the other GigabitEthernet interfaces following the same pattern described above, populating the respective IP addresses that correspond to the appropriate VLAN. Values for each VLAN are described below: a. GigabitEthernet0/0 (VLAN 1316) i. Name: WAN ii. Security Zone: WAN iii. IP Address: 192.168.4.50/24 b. GigabitEthernet0/1 (VLAN 1327) i. Name: Enterprise-Services ii. Security Zone: Enterprise-Services iii. IP Address: 192.168.40.1/24 c. GigabitEthernet0/2 (VLAN 1328) i. Name: HIS-Services

NIST SP 1800-30C: Securing Telehealth Remote Patient Monitoring Ecosystem

66

ii. Security Zone: HIS-Services iii. IP Address: 192.168.41.1/24 d. GigabitEthernet0/3 (VLAN 1329) i. Name: Remote-Services This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

ii. Security Zone: Remote-Services iii. IP Address: 192.168.42.1/24 e. GigabitEthernet0/4 (VLAN 1330) i. Name: Databases ii. Security Zone: Databases iii. IP Address: 192.168.43.1/24 f.

GigabitEthernet0/5 (VLAN 1347) i. Name: Clinical-Workstations ii. Security Zone: Clinical-Workstations iii. IP Address: 192.168.44.1/24

g. GigabitEthernet0/6 (VLAN 1348) i. Name: Security-Services ii. Security Zone: Security-Services iii. IP Address: 192.168.45.1/24 10. Click Save. 11. Click Deploy. Verify that the interfaces have been configured properly. Selecting the Devices tab, the Device Management screen displays the individual interfaces, assigned logical names, type of interface, security zone labeling, and assigned IP address network that corresponds to the VLANs that are assigned per security zone.

NIST SP 1800-30C: Securing Telehealth Remote Patient Monitoring Ecosystem

67

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

Configure Cisco FTD DHCP 1. From Devices > Device Management > FTD-TRPM > Interfaces, click DHCP. 2. Click the plus symbol next to Primary DNS Server.

3. The New Network Object pop-up window appears. Fill out the following information: a. Name: Umbrella-DNS-1 b. Network (Host): 192.168.40.30

NIST SP 1800-30C: Securing Telehealth Remote Patient Monitoring Ecosystem

68

4. Click Save.

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

5. Click the plus symbol next to Secondary DNS Server. 6. The New Network Object pop-up window appears. Fill out the following information: a. Name: Umbrella-DNS-2 b. Network (Host): 192.168.40.31 7. Under Domain Name, add hdo.trpm. 8. Click Add Server.

9. The Add Server pop-up window appears. Fill out the following information: a. Interface: Enterprise-Services

NIST SP 1800-30C: Securing Telehealth Remote Patient Monitoring Ecosystem

69

b. Address Pool: 192.168.40.100-192.168.40.254 c. Enable DHCP Server: checked 10. Click OK.

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

11. Add additional servers by following the same pattern described above, populating the respective Interface and Address Pool, and check the Enable DHCP Server that corresponds to the appropriate server. Values for each server are described below: a. Interface: Enterprise-Services i. Address Pool: 192.168.40.100-192.168.40.254 ii. Enable DHCP Server: checked b. Interface: HIS-Services i. Address Pool: 192.168.41.100-192.168.41.254 ii. Enable DHCP Server: checked c. Interface: Remote-Services i. Address Pool: 192.168.42.100-192.168.42.254 ii. Enable DHCP Server: checked d. Interface: Databases i. Address Pool: 192.168.43.100-192.168.43.254 ii. Enable DHCP Server: checked e. Interface: Clinical-Workstations

NIST SP 1800-30C: Securing Telehealth Remote Patient Monitoring Ecosystem

70

i. Address Pool: 192.168.44.100-192.168.44.254 ii. Enable DHCP Server: checked f.

Interface: Security-Services i. Address Pool: 192.168.45.100-192.168.45.254

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

ii. Enable DHCP Server: checked 12. Click Save. 13. Click Deploy. Verify that the DHCP servers have been configured properly. Select the Devices tab and review the DHCP server configuration settings. Values for Ping Timeout and Lease Length correspond to default values that were not altered. The Domain Name is set to hdo.trpm, with values that were set for the primary and secondary DNS servers. Below the DNS server settings, a Server tab displays the DHCP address pool that corresponds to each security zone. Under the Interface heading, view each security zone label that aligns to the assigned Address Pool and review that the Enable DHCP Server setting appears as a green check mark.

NIST SP 1800-30C: Securing Telehealth Remote Patient Monitoring Ecosystem

71

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

Configure Cisco FTD Static Route 1. From Devices > Device Management > FTD-TRPM > DHCP, click Routing. 2. Click Static Route.

NIST SP 1800-30C: Securing Telehealth Remote Patient Monitoring Ecosystem

72

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

3. Click Add Route.

4. The Add Static Route Configuration pop-up window appears. Fill out the following information: a. Interface: WAN b. Selected Network: any-ipv4

NIST SP 1800-30C: Securing Telehealth Remote Patient Monitoring Ecosystem

73

5. Click the plus symbol next to Gateway.

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

6. The New Network Object pop-up window appears. Fill out the following information: a. Name: HDO-Upstream-Gateway b. Network (Host): 192.168.4.1 7. Click Save.

NIST SP 1800-30C: Securing Telehealth Remote Patient Monitoring Ecosystem

74

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

8. Click OK.

75

NIST SP 1800-30C: Securing Telehealth Remote Patient Monitoring Ecosystem

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

9. Click Save. 10. Click Deploy. Verify that the static route has been set correctly. From Devices, when selecting the Routing tab, the Static Route will indicate the network routing settings. The screen displays the static route settings in a table format that includes values for Network, Interface, Gateway, Tunneled, and Metric. The static route applies to the IP addressing that has been specified, where network traffic traverses the interface. Note the Gateway value. The Tunneled and Metric values display the default value.

NIST SP 1800-30C: Securing Telehealth Remote Patient Monitoring Ecosystem

76

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

Configure Cisco FTD Network Address Translation (NAT) 1. Click Devices > NAT. 2. Click New Policy > Threat Defense NAT.

3. The New Policy pop-up window appears. Fill out the following information: a. Name: TRPM NAT b. Selected Devices: FTD-TRPM 4. Click Save.

NIST SP 1800-30C: Securing Telehealth Remote Patient Monitoring Ecosystem

77

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

5. Click the edit symbol for TRPM NAT.

6. Click Add Rule.

NIST SP 1800-30C: Securing Telehealth Remote Patient Monitoring Ecosystem

78

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

7. The Edit NAT Rule pop-up window appears. Under Interface Objects, fill out the following information: a. NAT Rule: Auto NAT Rule b. Type: Dynamic c. Source Interface Objects: Enterprise-Services d. Destination Interface Objects: WAN 8. Click Translation.

9. Under Translation, fill out the following information: a. Original Source: Enterprise-Services b. Translated Source: Destination Interface IP 10. Click OK.

NIST SP 1800-30C: Securing Telehealth Remote Patient Monitoring Ecosystem

79

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

11. Create additional rules following the same pattern described above, populating the respective information for each rule. Values for each rule are described below: a. HIS-Services i. NAT Rule: Auto NAT Rule ii. Type: Dynamic iii. Source Interface Objects: HIS-Services iv. Destination Interface Objects: WAN v. Original Source: HIS-Services vi. Translated Source: Destination Interface IP b. Remote-Services i. NAT Rule: Auto NAT Rule ii. Type: Dynamic iii. Source Interface Objects: Remote-Services iv. Destination Interface Objects: WAN v. Original Source: Remote-Services vi. Translated Source: Destination Interface IP

NIST SP 1800-30C: Securing Telehealth Remote Patient Monitoring Ecosystem

80

c. Databases i. NAT Rule: Auto NAT Rule ii. Type: Dynamic iii. Source Interface Objects: Databases This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

iv. Destination Interface Objects: WAN v. Original Source: Databases vi. Translated Source: Destination Interface IP d. Clinical-Workstations i. NAT Rule: Auto NAT Rule ii. Type: Dynamic iii. Source Interface Objects: Clinical-Workstations iv. Destination Interface Objects: WAN v. Original Source: Clinical-Workstations vi. Translated Source: Destination Interface IP e. Security-Services i. NAT Rule: Auto NAT Rule ii. Type: Dynamic iii. Source Interface Objects: Security-Services iv. Destination Interface Objects: WAN v. Original Source: Security-Services vi. Translated Source: Destination Interface IP 12. Click Save. 13. Click Deploy. Verify the NAT settings through the Devices screen. The NAT rules are displayed in a table format. The table includes values for Direction of the NAT displayed as a directional arrow, the NAT Type, the Source Interface Objects (i.e., the security zone IP networks), the Destination Interface Objects, the Original Sources (i.e., these addresses correspond to the IP network from where the network traffic originates), the Translated Sources, and Options. The

NIST SP 1800-30C: Securing Telehealth Remote Patient Monitoring Ecosystem

81

settings indicate that IP addresses from the configured security zones are translated behind the Interface IP address.

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

Configure Cisco FTD Access Control Policy 1. Click Polices > Access Control > Access Control. 2. Click the edit symbol for Default-TRPM.

3. Click Add Category.

NIST SP 1800-30C: Securing Telehealth Remote Patient Monitoring Ecosystem

82

4. Fill out the following information: a. Name: Security Services b. Insert: into Mandatory 5. Click OK. This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

6. Repeat the previous steps of Add Category section for each network segment in the architecture. 7. Click Add Rule.

8. When the Add Rule screen appears, fill out the following information: a. Name: Nessus-Tenable b. Action: Allow c. Insert: into Category, Security Services d. Under Networks, click the plus symbol next to Available Networks and select Add Object.

NIST SP 1800-30C: Securing Telehealth Remote Patient Monitoring Ecosystem

83

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

9. When the New Network Object pop-up window appears, fill out the following information: a. Name: Tenable.sc b. Network (Host): 192.168.45.101 10. Click Save.

11. In the Add Rule screen, under the Networks tab, set Destination Networks to Tenable.sc. 12. Click Ports.

NIST SP 1800-30C: Securing Telehealth Remote Patient Monitoring Ecosystem

84

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

13. In the Add Rule screen, under the Ports tab, set Selected Destination Ports to 8834. 14. Click Add.

15. Repeat the previous steps for any network requirement rules if necessary. 16. Click Save. 17. Click Deploy.

2.2.3 Security Continuous Monitoring The project team implemented a set of tools that included Cisco Stealthwatch, Cisco Umbrella, and LogRhythm to address security continuous monitoring. This practice guide uses Cisco Stealthwatch for

NIST SP 1800-30C: Securing Telehealth Remote Patient Monitoring Ecosystem

85

NetFlow analysis. Cisco Umbrella is a service used for DNS-layer monitoring. The LogRhythm tools aggregate log file information from across the HDO infrastructure and allow behavioral analytics.

2.2.4 Cisco Stealthwatch

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

Cisco Stealthwatch provides network visibility and analysis through network telemetry. This project integrates Cisco Stealthwatch with Cisco Firepower, sending NetFlow directly from the Cisco FTD appliance to a Stealthwatch Flow Collector (SFC) for analysis. Cisco Stealthwatch Management Center (SMC) Appliance Information CPU: 4 RAM: 16 GB Storage: 200 GB (Thick Provision) Network Adapter 1: VLAN 1348 Operating System: Linux Cisco SMC Appliance Installation Guide Install the appliance according to the instructions detailed in the Cisco Stealthwatch Installation and Configuration Guide 7.1 [8]. Cisco SFC Appliance Information CPU: 4 RAM: 16 GB Storage: 300 GB (Thick Provision) Network Adapter 1: VLAN 1348 Operating System: Linux Cisco SFC Appliance Installation Guide Install the appliance according to the instructions detailed in the Cisco Stealthwatch Installation and Configuration Guide 7.1 [8]. Accept the default port value 2055 for NetFlow. Configure Cisco FTD NetFlow for Cisco SFC 1. Click Objects > Object Management > FlexConfig > Text Object.

NIST SP 1800-30C: Securing Telehealth Remote Patient Monitoring Ecosystem

86

2. In the search box, type netflow. 3. Click the edit symbol for netflow_Destination.

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

4. When the Edit Text Object pop-up window appears, fill out the following information: a. Count: 3 b. 1: Security Services c. 2: 192.168.45.31 d. 3: 2055 e. Allow Overrides: checked 5. Click Save.

NIST SP 1800-30C: Securing Telehealth Remote Patient Monitoring Ecosystem

87

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

6. Click the edit symbol for netflow_Event_Types.

NIST SP 1800-30C: Securing Telehealth Remote Patient Monitoring Ecosystem

88

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

7. When the Edit Text Object pop-up window appears, fill out the following information: a. Count: 1 b. 1: All c. Allow Overrides: checked 8. Click Save.

NIST SP 1800-30C: Securing Telehealth Remote Patient Monitoring Ecosystem

89

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

9. Click Devices > FlexConfig. 10. Click New Policy.

11. When the New Policy screen appears, fill out the following information: a. Name: FTD-FlexConfig b. Selected Devices: FTD-TRPM 12. Click Save.

NIST SP 1800-30C: Securing Telehealth Remote Patient Monitoring Ecosystem

90

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

13. Click the edit symbol for FTD-FlexConfig.

14. Under the Devices tab, select Netflow_Add_Destination and Netflow_Set_Parameters. 15. Click the right-arrow symbol to move the selections to the Selected Append FlexConfigs section.

NIST SP 1800-30C: Securing Telehealth Remote Patient Monitoring Ecosystem

91

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

16. Click Save. 17. Click Deploy. From the Devices screen, verify the FlexConfig settings. Select the FlexConfig tab. The NetFlow configurations appear in the lower right of the screen as a table. Under Selected Append FlexConfigs, the table includes columns labeled # that corresponds to the number of configurations that have been made: Name and Description.

NIST SP 1800-30C: Securing Telehealth Remote Patient Monitoring Ecosystem

92

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

Create a Custom Policy Management Rule 1. Click Configure > Policy Management.

2. Click Create New Policy > Role Policy.

NIST SP 1800-30C: Securing Telehealth Remote Patient Monitoring Ecosystem

93

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

3. Give the policy a name and description. 4. Under Host Groups, click the plus symbol.

5. Under Outside Hosts, select Eastern Asia and Eastern Europe. 6. Click Apply.

NIST SP 1800-30C: Securing Telehealth Remote Patient Monitoring Ecosystem

94

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

7. Under Core Events, click Select Events.

NIST SP 1800-30C: Securing Telehealth Remote Patient Monitoring Ecosystem

95

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

8. Select Recon. 9. Click Apply.

NIST SP 1800-30C: Securing Telehealth Remote Patient Monitoring Ecosystem

96

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

10. Under Core Events > Recon > When Host is Source, select On + Alarm. 11. Click the expand arrow next to Recon.

12. Select Behavioral and Threshold.

NIST SP 1800-30C: Securing Telehealth Remote Patient Monitoring Ecosystem

97

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

13. Click Save.

98

NIST SP 1800-30C: Securing Telehealth Remote Patient Monitoring Ecosystem

2.2.4.1 Cisco Umbrella Cisco Umbrella is a cloud service that provides protection through DNS-layer security. Engineers deployed two Umbrella virtual appliances in the HDO to provide DNS routing and protection from malicious web services. Cisco Umbrella Forwarder Appliance Information This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

CPU: 1 RAM: 0.5 GB Storage: 6.5 GB (Thick Provision) Network Adapter 1: VLAN 1327 Operating System: Linux Cisco Umbrella Forwarder Appliance Installation Guide Install the appliance according to the instructions detailed in Cisco’s Deploy VAs in VMware guidance [9]. Create an Umbrella Site 1. Click Deployments > Configuration > Sites and Active Directory. 2. Click Settings.

3. Click Add New Site.

NIST SP 1800-30C: Securing Telehealth Remote Patient Monitoring Ecosystem

99

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

4. In the Add New Site pop-up window, set Name to HDO. 5. Click Save.

6. Click Deployments > Configuration > Sites and Active Directory. 7. Click the edit symbol for the Site of forwarder-1. 8. Under Site, select HDO. 9. Click Save.

NIST SP 1800-30C: Securing Telehealth Remote Patient Monitoring Ecosystem

100

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

10. Repeat the previous steps for forwarder-2.

Configure an Umbrella Policy 1. Click Policies > Management > All Policies. 2. Click Add.

3. Expand the Sites identity.

NIST SP 1800-30C: Securing Telehealth Remote Patient Monitoring Ecosystem

101

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

4. Select HDO. 5. Click Next.

NIST SP 1800-30C: Securing Telehealth Remote Patient Monitoring Ecosystem

102

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

6. Click Next.

103

NIST SP 1800-30C: Securing Telehealth Remote Patient Monitoring Ecosystem

7. Click Next.

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

8. Select Moderate. 9. Click Next.

NIST SP 1800-30C: Securing Telehealth Remote Patient Monitoring Ecosystem

104

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

10. Under Application Settings, use the drop-down menu to select Create New Setting.

11. Under the Control Applications screen, fill out the following information:

NIST SP 1800-30C: Securing Telehealth Remote Patient Monitoring Ecosystem

105

a. Name: HDO Application Control b. Applications to Control: Cloud Storage 12. Click Save.

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

13. Click Next.

NIST SP 1800-30C: Securing Telehealth Remote Patient Monitoring Ecosystem

106

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

14. Click Next.

NIST SP 1800-30C: Securing Telehealth Remote Patient Monitoring Ecosystem

107

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

15. Click Next.

16. Click Next.

NIST SP 1800-30C: Securing Telehealth Remote Patient Monitoring Ecosystem

108

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

17. In the Policy Summary screen, set the Name to HDO Site Policy. 18. Click Save.

NIST SP 1800-30C: Securing Telehealth Remote Patient Monitoring Ecosystem

109

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

Configure Windows Domain Controller as the Local DNS Provider 1. Click Deployments > Configuration > Domain Management. 2. Click Add.

NIST SP 1800-30C: Securing Telehealth Remote Patient Monitoring Ecosystem

110

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

3. In the Add New Bypass Domain or Server popup window, fill out the following information: a. Domain: hdo.trpm b. Applies To: All Sites, All Devices 4. Click Save. Verify that the rule for the hdo.trpm has been added.

NIST SP 1800-30C: Securing Telehealth Remote Patient Monitoring Ecosystem

111

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

2.2.4.2 LogRhythm XDR (Extended Detection and Response) LogRhythm XDR is a SIEM system that receives log and machine data from multiple end points and evaluates the data to determine when cybersecurity events occur. The project utilizes LogRhythm XDR in

NIST SP 1800-30C: Securing Telehealth Remote Patient Monitoring Ecosystem

112

the HDO environment to enable a continuous view of business operations and detect cyber threats on assets. System Requirements CPU: 20 virtual central processing units (vCPUs) Memory: 96 GB RAM This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

Storage:   

hard drive C: 220 GB hard drive D: 1 terabyte (TB) hard drive L: 150 GB

Operating System: Microsoft Windows Server 2016 X64 Standard Edition Network Adapter: VLAN 1348 LogRhythm XDR Installation This section describes LogRhythm installation processes. Download Installation Packages 1. Acquire the installation packages from LogRhythm, Inc. 2. Prepare a virtual Windows Server per the system requirements. 3. Create three new drives. 4. Create a new folder from C:\ on the Platform Manager server and name the folder LogRhythm. 5. Extract the provided Database Installer tool and LogRhythm XDR Wizard from the installation package in C:\LogRhythm. Install Database 1. Open LogRhythmDatabaseInstallTool folder. 2. Double-click LogRhythmDatabaseInstallTool application file. 3. Click Run. 4. A LogRhythm Database Setup window will appear. Set the Which setup is this for? to PM and use the default values for Disk Usage.

NIST SP 1800-30C: Securing Telehealth Remote Patient Monitoring Ecosystem

113

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

5. The remaining fields will automatically populate with the appropriate values. Click Install. 6. Click Done to close the LogRhythm Database Setup window. Install LogRhythm XDR 1. Navigate to C:\ and open LogRhythm XDR Wizard folder. 2. Double-click the LogRhythmInstallerWizard application file. 3. The LogRhythm Install Wizard 7.4.8 window will appear. 4. Click Next. 5. A LogRhythm Install Wizard Confirmation window will appear. 6. Click Yes to continue. 7. Check the box beside I accept the terms in the license agreement to accept the License Agreement. 8. Click Next. 9. In the Selected Applications window, select the following attributes: a. Configuration: Select the XM radio button.

NIST SP 1800-30C: Securing Telehealth Remote Patient Monitoring Ecosystem

114

b. Optional Applications: Check both AI Engine and Web Console boxes. 10. Click Install.

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

11. A LogRhythm Deployment Tool window displays. 12. Click Configure New Deployment.

NIST SP 1800-30C: Securing Telehealth Remote Patient Monitoring Ecosystem

115

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

13. In the Deployment Properties window, keep the default configurations and click Ok.

NIST SP 1800-30C: Securing Telehealth Remote Patient Monitoring Ecosystem

116

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

14. Click +Add Host IP in the bottom right corner of the screen and provide the following information: a. IP Address: 192.168.45.20 b. Nickname: XM 15. Click Save.

NIST SP 1800-30C: Securing Telehealth Remote Patient Monitoring Ecosystem

117

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

16. Click Create Deployment Package in the bottom right corner of the screen. 17. A Create Deployment Package window displays. 18. Click Create Deployment Package.

19. A Select Folder window appears. 20. Navigate to C:\LogRhythm. 21. Click Select Folder.

NIST SP 1800-30C: Securing Telehealth Remote Patient Monitoring Ecosystem

118

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

22. Click Next Step.

23. Click Run Host Installer on this Host.

NIST SP 1800-30C: Securing Telehealth Remote Patient Monitoring Ecosystem

119

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

24. After the Host Installer has finished, click Verify Status.

25. Click Exit to Install Wizard.

NIST SP 1800-30C: Securing Telehealth Remote Patient Monitoring Ecosystem

120

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

26. A notification window displays stating the installation could take as long as 30 minutes. Click OK.

NIST SP 1800-30C: Securing Telehealth Remote Patient Monitoring Ecosystem

121

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

27. After the Install Wizard has successfully installed the services, click Exit.

NIST SP 1800-30C: Securing Telehealth Remote Patient Monitoring Ecosystem

122

LogRhythm XDR Configuration The LogRhythm XDR configuration includes multiple related components:

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

System Monitor

LogRhythm Artificial Intelligence (AI) Engine

Mediator Server

Job Manager

LogRhythm Console

Configure System Monitor 1. Open File Explorer and navigate to C:\Program Files\LogRhythm. 2. Navigate to LogRhythm System Monitor. 3. Double-click the lrconfig application file. 4. In the LogRhythm System Monitor Local Configuration Manager window, provide the following information and leave the remaining fields as their default values: a. Data Processor Address: 192.168.45.20 b. System Monitor IP Address/Index: 192.168.45.20 5. Click Apply and then click OK.

NIST SP 1800-30C: Securing Telehealth Remote Patient Monitoring Ecosystem

123

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

Configure LogRhythm AI Engine 1. Open File Explorer and navigate to C:\Program Files\LogRhythm. 2. Navigate to LogRhythm AI Engine. 3. Double-click the lrconfig application file. 4. In the LogRhythm AI Engine Local Configuration Manager window, provide the following information and leave the remaining fields as their default values: a. Server: 192.168.45.20 b. Password: ********** 5. Click Test Connection, then follow the instruction of the alert window to complete the test connection. 6. Click Apply and then click OK.

NIST SP 1800-30C: Securing Telehealth Remote Patient Monitoring Ecosystem

124

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

Configure Mediator Server 1. Open File Explorer and navigate to C:\Program Files\LogRhythm. 2. Navigate to Mediator Server. 3. Double-click lrconfig application file. 4. In the LogRhythm Data Processor Local Configuration Manager window, provide the following information and leave the remaining fields as their default values: a. Server: 192.168.45.20 b. Password: **********

NIST SP 1800-30C: Securing Telehealth Remote Patient Monitoring Ecosystem

125

5. Click Test Connection, then follow the instruction of the alert window to complete the test connection. 6. Click Apply and then click OK.

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30. NIST SP 1800-30C: Securing Telehealth Remote Patient Monitoring Ecosystem

126

Configure Job Manager 1. Open File Explorer and navigate to C:\Program Files\LogRhythm. 2. Navigate to Job Manager. 3. Double-click the lrconfig application file. This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

4. In the LogRhythm Platform Manager Local Configuration Manager window, provide the following information and leave the remaining fields as their default values: a. Server: 192.168.45.20 b. Password: ********** 5. Click Test Connection, then follow the instruction of the alert window to complete the test connection. 6. Click Apply and then click OK.

NIST SP 1800-30C: Securing Telehealth Remote Patient Monitoring Ecosystem

127

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

7. Navigate to the Alarming and Response Manager tab in the bottom menu ribbon. 8. In the Alarming and Response Manager window, provide the following information and leave the remaining fields as their default values: a. Server: 192.168.45.20

NIST SP 1800-30C: Securing Telehealth Remote Patient Monitoring Ecosystem

128

b. Password: ********** 9. Click Test Connection, then follow the instruction of the alert window to complete the test connection. 10. Click Apply and then click OK. This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30. NIST SP 1800-30C: Securing Telehealth Remote Patient Monitoring Ecosystem

129

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

Configure LogRhythm Console 1. Open File Explorer and navigate to C:\Program Files\LogRhythm. 2. Navigate to LogRhythm Console.

NIST SP 1800-30C: Securing Telehealth Remote Patient Monitoring Ecosystem

130

3. Double-click lrconfig application file. 4. In the LogRhythm Login window, provide the following information: a. EMDB Server: 192.168.45.20 b. UserID: LogRhythmAdmin This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

c. Password: ******** 5. Click OK.

6. A New Platform Manager Deployment Wizard window displays. Provide the following information: a. Windows host name for Platform Manager: LogRhythm-XDR b. IP Address for Platform Manager: 192.168.45.20 c. Check the box next to The Platform Manager is also a Data Processor (e.g., an XM appliance).

NIST SP 1800-30C: Securing Telehealth Remote Patient Monitoring Ecosystem

131

d. Check the box next to The Platform Manager is also an AI Engine Server. 7. Click the ellipsis button next to <Path to LogRhythm License File> and navigate to the location of the LogRhythm License File.

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

8. The New Knowledge Base Deployment Wizard window displays and shows the import progress status. Once LogRhythm has successfully imported the file, a message window will appear stating more configurations need to be made for optimum performance. Click OK to open the Platform Manager Properties window. 9. In the Platform Manager Properties window, provide the following information: a. Email address: no_reply@logrhythm.com b. Address: 192.168.45.20 10. Click the button next to Platform, enable the Custom Platform radio button and complete the process by clicking Apply, followed by clicking OK.

NIST SP 1800-30C: Securing Telehealth Remote Patient Monitoring Ecosystem

132

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

11. After the Platform Manager Properties window closes, a message window displays for configuring the Data Processor. Click OK to open the Data Processor Properties window. 12. Click the button next to Platform and enable the Custom Platform radio button. 13. Click OK. 14. Leave the remaining fields in the Data Processor Properties window as their default values and click Apply. 15. Click OK to close the window.

NIST SP 1800-30C: Securing Telehealth Remote Patient Monitoring Ecosystem

133

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

Set LogRhythm-XDR for System Monitor 1. Back in the LogRhythm console, navigate to the Deployment Manager tab in the menu ribbon. 2. Navigate to System Monitors on the Deployment Manager menu ribbon. 3. Double-click LogRhythm-XDR.

NIST SP 1800-30C: Securing Telehealth Remote Patient Monitoring Ecosystem

134

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

4. In the System Monitor Agent Properties window, navigate to Syslog and Flow Settings. 5. Click the checkbox beside Enable Syslog Server. 6. Click OK to close the System Monitor Agent Properties window.

Use the LogRhythm Web Console 1. Open a web browser and navigate to https://localhost:8443.

NIST SP 1800-30C: Securing Telehealth Remote Patient Monitoring Ecosystem

135

2. Enter the Username: logrhythmadmin 3. Enter the Password: **********

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

2.2.4.3 LogRhythm NetworkXDR LogRhythm NetworkXDR paired with LogRhythm XDR enables an environment to monitor network traffic between end points and helps suggest remediation techniques for identified concerns. This project utilizes NetworkXDR for continuous visibility on network traffic between HDO VLANs and incoming traffic from the telehealth platform provider. System Requirements CPU: 24 vCPUs Memory: 64 GB RAM Storage:  Operating System Hard Drive: 220 GB  Data Hard Drive: 3 TB  Operating System: CentOS 7 Network Adapter: VLAN 1348 LogRhythm NetworkXDR Installation LogRhythm provides an International Organization for Standardization (.iso) disk image to simplify installation of NetMon. The .iso is a bootable image that installs CentOS 7.7 Minimal and NetMon. Note: Because this is an installation on a Linux box, there is no need to capture the screenshots.

NIST SP 1800-30C: Securing Telehealth Remote Patient Monitoring Ecosystem

136

Download the Installation Software 1. Open a new tab in the web browser and navigate to https://community.logrhythm.com. 2. Log in using the appropriate credentials. 3. Click LogRhythm Community. This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

4. Navigate to Documentation & Downloads. 5. Register a Username. 6. Click Accept. 7. Click Submit. 8. Navigate to NetMon. 9. Click downloads: netmon4.0.2. 10. Select NetMon ISO under Installation Files. Install LogRhythm NetworkXDR 1. In the host server, mount the .iso for the installation. 2. Start the VM with the mounted .iso. 3. When the welcome screen loads, select Install LogRhythm Network Monitor. 4. The installer completes the installation, and the system reboots. 5. When the system reboots, log in to the console by using logrhythm as the login and ****** as the password. 6. Then change the password by typing the command passwd, type the default password, and then type and verify the new password. LogRhythm NetworkXDR Configuration 1. Data Process Address: 192.168.45.20 2. Click Apply.

NIST SP 1800-30C: Securing Telehealth Remote Patient Monitoring Ecosystem

137

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

3. Click the Windows Service tab. 4. Change the Service Type to Automatic. 5. Click Apply.

NIST SP 1800-30C: Securing Telehealth Remote Patient Monitoring Ecosystem

138

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

6. Click the Log File tab. 7. Click Refresh to ensure NetworkXDR log collection. 8. Click OK to exit the Local Configuration Manager.

NIST SP 1800-30C: Securing Telehealth Remote Patient Monitoring Ecosystem

139

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

2.2.4.4 LogRhythm System Monitor Agent LogRhythm System Monitor Agent is a component of LogRhythm XDR that receives end-point log files and machine data in an IT infrastructure. The system monitor transmits ingested data to LogRhythm XDR where a web-based dashboard displays any identified cyber threats. This project deploys LogRhythm’s System Monitor Agents on end points in each identified VLAN. Install the LogRhythm System Monitor Agent on one of the end points (e.g., Clinical Workstation) in the HDO environment so that the LogRhythm XDR can monitor the logs, such as syslog and eventlog, of this workstation.

NIST SP 1800-30C: Securing Telehealth Remote Patient Monitoring Ecosystem

140

System Monitor Agent Installation This section describes installation of the system monitor agent. Download Installation Packages 1. Using a Clinical Workstation, open a web browser. This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

2. Navigate to https://community.logrhythm.com. 3. Log in using the credentials made when installing and configuring LogRhythm XDR. 4. Navigate to LogRhythm Community. 5. Click Documents & Downloads. 6. Click SysMon. 7. Click SysMon – 7.4.10. 8. Click Windows System Monitor Agents and save to the Downloads folder on the Workstation. Install System Monitor Agent 1. On the Workstation, navigate to Downloads folder. 2. Click LRWindowsSystemMonitorAgents. 3. Click LRSystemMonitor_64_7. 4. On the Welcome page, follow the Wizard and click Next….

NIST SP 1800-30C: Securing Telehealth Remote Patient Monitoring Ecosystem

141

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

5. On the ready to begin installation page, click Install.

6. Click Finish.

NIST SP 1800-30C: Securing Telehealth Remote Patient Monitoring Ecosystem

142

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

System Monitor Agent Configuration 1. After exiting the LogRhythm System Monitor Service Install Wizard, a LogRhythm System Monitor Local Configuration window displays. Under the General tab, provide the following information: a. Data Process Address: 192.168.45.20 b. System Monitor IP Address/Index: 192.168.45.20 2. Click Apply.

NIST SP 1800-30C: Securing Telehealth Remote Patient Monitoring Ecosystem

143

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

3. Click the Windows Service tab. 4. Change the Service Type to Automatic. 5. Click Apply.

NIST SP 1800-30C: Securing Telehealth Remote Patient Monitoring Ecosystem

144

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

6. Click the Log File tab. 7. Click Refresh to ensure NetworkXDR log collection. 8. Click OK to exit the Local Configuration Manager.

NIST SP 1800-30C: Securing Telehealth Remote Patient Monitoring Ecosystem

145

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

Add Workstation for System Monitor Engineers added Clinical Workstation for System Monitor and Set Its Message Source Types in the LogRhythm Deployment Manager. 1. Log in to the LogRhythm Console. a. User ID: LogRhythmAdmin b. Password: **********

NIST SP 1800-30C: Securing Telehealth Remote Patient Monitoring Ecosystem

146

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

2. Navigate to the Deployment Manager in the menu ribbon.

NIST SP 1800-30C: Securing Telehealth Remote Patient Monitoring Ecosystem

147

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

3. Under Entity Hosts, click on New.

NIST SP 1800-30C: Securing Telehealth Remote Patient Monitoring Ecosystem

148

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

4. Click New to open the Host pop-up window and enter the following under the Basic Information tab: a. Name: ClinicalWS b. Host Zone: Internal

NIST SP 1800-30C: Securing Telehealth Remote Patient Monitoring Ecosystem

149

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

5. Navigate to the Identifiers tab, provide the following information in the appropriate fields and click Add. a. IP Address: 192.168.44.251 b. Windows Name: clinicalws (Windows Name)

NIST SP 1800-30C: Securing Telehealth Remote Patient Monitoring Ecosystem

150

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

6. Add the ClinicalWS as a new system monitor agent by navigating to the System Monitors tab, right-clicking in the empty space, and selecting New. 7. In the System Monitor Agent Properties window, click the button next to Host Agent is Installed on and select Primary Site: ClinicalWS.

NIST SP 1800-30C: Securing Telehealth Remote Patient Monitoring Ecosystem

151

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

8. Go to System Monitors. 9. Double-click ClinicalWS. 10. Under LogSource of the System Monitor Agent Property window, right-click in the empty space and select New. The Log Message Source Property window will open. 11. Under the Log Message Source Property window, click the button associated with Log Message Source Type. It will open the Log Source Selector window. 12. In the text box to the right of the Log Source Selector window, type XML, and click Apply. 13. Select the Log Source Type and click OK.

NIST SP 1800-30C: Securing Telehealth Remote Patient Monitoring Ecosystem

152

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

2.2.5 Data Security Data security controls align with the NIST Cybersecurity Framework’s PR.DS category. For this practice guide, the Onclave Networks solution was implemented as a component in the simulated patient home and simulated telehealth platform provider cloud environment. The Onclave Networks suite of tools provides secure communication between the two simulated environments when using broadband communications to exchange data.

2.2.5.1 Onclave SecureIoT The Onclave SecureIoT deployment consists of six components: Onclave Blockchain, Onclave Administrator Console, Onclave Orchestrator, Onclave Bridge, and two Onclave Gateways. These components work together to provide secure network sessions between the deployed gateways. Onclave SecureIoT Virtual Appliance Prerequisites All Onclave devices require Debian 9.9/9.11/9.13. In addition, please prepare the following: 1. GitHub account.

NIST SP 1800-30C: Securing Telehealth Remote Patient Monitoring Ecosystem

153

2. Request an invitation to the Onclave Github account. Once the GitHub invitation has been accepted and a Debian VM has been installed in the virtual environment, download and run the installation script to prepare the VM for configuration. 1. Run the command sudo apt-get update 2. Run the command apt install git -y This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

3. Run the command sudo apt install openssh-server 4.

Run the command git clone

https://readonly:Sh1bboleth45@gitlab.onclave.net/onclave/build/install.git

5. Navigate to the /home/onclave/install directory. 6. Run the command chmod +x *.sh This process can be repeated for each virtual appliance that is deployed. The following guidance assumes the system user is named onclave. Onclave SecureIoT Blockchain Appliance Information CPU: 4 RAM: 8 GB Storage: 120 GB (Thick Provision) Network Adapter 1: VLAN 1317 Operating System: Debian Linux 9.11 Onclave SecureIoT Blockchain Appliance Configuration Guide Before starting the installation script, prepare an answer for each question. The script will configure the server, assign a host name, create a self-signed certificate, and start the required services. 1. Run the command nano/etc/hosts a. Edit the Hosts file to include the IP address and domain name of each Onclave device, as well as Onclave’s docker server. This will include: i. 192.168.5.11 tele-adco.trpm.hclab ii. 192.168.5.12 tele-orch.trpm.hclab iii. 192.168.5.13 tele-bg.trpm.hclab

NIST SP 1800-30C: Securing Telehealth Remote Patient Monitoring Ecosystem

154

iv. 192.168.5.14 tele-gw1.trpm.hclab v. 192.168.21.10 tele-gw2.trpm.hclab vi. 38.142.224.131 docker.onclave.net 2. Save the file and exit. This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

3. Navigate to the /home/onclave/install directory. 4. Run the command ./go.sh and fill out the following information: a. What type of device is being deployed?: bci b. Enter device hostname (NOT FQDN): tele-bci c. Enter device DNS domain name: trpm.hclab d. Enter the public NIC: ens192 e. Enter the private NIC, if does not exist type in NULL: NULL f.

Enter the IP Settings (DHCP or Static): PUBLIC NIC (Static) i. address 192.168.5.10 ii. netmask 255.255.255.0 iii. gateway 192.168.5.1 iv. dns-nameservers 192.168.1.10

g. What is the BCI FQDN for this environment?: tele-bci.trpm.hclab h. Enter the Docker Service Image Path: NULL i.

Will system need TPM Emulator? (yes/no): no

j.

Keystore/Truststore password to be used?: Onclave56

k. GitLab Username/Password (format username:password): readonly:Sh1bboleth45 5. Wait for the Blockchain server to reboot. 6. Login to the appliance. 7. Run the command su root and enter the password. 8. Wait for the configuration process to finish.

NIST SP 1800-30C: Securing Telehealth Remote Patient Monitoring Ecosystem

155

Onclave SecureIoT Administrator Console Appliance Information CPU: 4 RAM: 8 GB Storage: 32 GB (Thick Provision) This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

Network Adapter 1: VLAN 1317 Operating System: Debian Linux 9.11 Onclave SecureIoT Administrator Console Appliance Configuration Guide 1. Run the command scp onclave@192.168.5.10:/home/onclave/blockchain/certs/telebci.trpm.hclab.crt /root/certs

2. Run the command nano/etc/hosts a. Edit the Hosts file to include the IP address and domain name of each Onclave device, as well as Onclave’s docker server. This will include: i. 192.168.5.10 tele-bci.trpm.hclab ii. 192.168.5.12 tele-orch.trpm.hclab iii. 192.168.5.13 tele-bg.trpm.hclab iv. 192.168.5.14 tele-gw1.trpm.hclab v. 192.168.21.10 tele-gw2.trpm.hclab vi. 38.142.224.131 docker.onclave.net b. Save the file and exit. 3. Navigate to the /home/onclave/install directory. 4. Run the command chmod +x *.sh 5. Run the command ./go.sh and fill out the following information: a. What type of device is being deployed?: adco b. Enter device hostname (NOT FQDN): tele-adco c. Enter device DNS domain name: trpm.hclab d. Enter the public NIC: ens192

NIST SP 1800-30C: Securing Telehealth Remote Patient Monitoring Ecosystem

156

e. Enter the private NIC, if does not exist type in NULL: NULL f.

Enter the IP Settings (DHCP or Static): PUBLIC NIC (Static) i. address 192.168.5.11 ii. netmask 255.255.255.0

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

iii. gateway 192.168.5.1 iv. dns-nameservers 192.168.1.10 g. What is the BCI FQDN for this environment?: tele-bci.trpm.hclab h. Enter the Docker Service Image Path: NULL i.

Will system need TPM Emulator? (yes/no): yes

j.

Keystore/Truststore password to be used?: Onclave56

k. GitLab Username/Password (format username:password): readonly:Sh1bboleth45 6. Wait for the Administrator Console server to reboot. 7. Login to the appliance. 8. Run the command su root and enter the password. 9. Wait for the configuration process to finish. 10. Navigate to the /home/onclave directory. 11. Run the command docker pull docker.onclave.net/orchestrator-service:1.1.0 12. Run the command docker pull docker.onclave.net/bridge-service:1.1.0 13. Run the command docker pull docker.onclave.net/gateway-service:1.1.0 Administrator Console Initialization and Bundle Creation 1. Using a web browser, navigate to https://tele-adco.trpm.hclab. 2. Click Verify. 3. Provide the following information: a. Software ID (provided by Onclave) b. Password (provided by Onclave) c. PIN (provided by Onclave)

NIST SP 1800-30C: Securing Telehealth Remote Patient Monitoring Ecosystem

157

4. Provide the following information to create a superuser account: a. First Name: ***** b. Last Name: ***** c. Username: *****@email.com This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

d. Password: ******** e. Organization Name: NCCoEHC 5. Click Software Bundles. 6. Click the plus symbol (top right) and provide the following information: a. Bundle name: nccoe-tele-orch b. Bundle type: Orchestrator c. Owned by: NCCoEHC d. Orchestrator owner name: HCLab e. PIN: **** f.

Password: ********

7. Click Create. 8. Click the plus symbol (top right) and provide the following information: a. Bundle name: nccoe-tele-bg b. Bundle type: Bridge c. Owned by: NCCoEHC 9. Click Create. 10. Click the plus symbol (top right) and provide the following information: a. Bundle name: nccoe-tele-gw b. Bundle type: Gateway c. Owned by: NCCoEHC 11. Click Create.

NIST SP 1800-30C: Securing Telehealth Remote Patient Monitoring Ecosystem

158

Transfer Ownership of Onclave Devices to the Orchestrator Once each Onclave device has been created and provisioned, it will show up in the Admin Console’s web GUI. From here, the devices can be transferred to the Orchestrator with the following steps: 1. Using a web browser, navigate to https://tele-adco.trpm.hclab. 2. Click Devices. This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

3. Select the checkbox next to tele-bg, tele-gw1, and tele-gw2. 4. Click Transfer ownership. 5. Under Select a new owner, select HCLab. 6. Click Transfer ownership. Onclave SecureIoT Orchestrator Appliance Information CPU: 4 RAM: 8 GB Storage: 32 GB (Thick Provision) Network Adapter 1: VLAN 1317 Operating System: Debian Linux 9.11 Onclave SecureIoT Orchestrator Appliance Configuration Guide 1. Run the command scp onclave@192.168.5.10:/home/onclave/blockchain/certs/telebci.trpm.hclab.crt /root/certs

2. Run the command nano/etc/hosts a. Edit the Hosts file to include the IP address and domain name of each Onclave device, as well as Onclave’s docker server. This will include: i. 192.168.5.10 tele-bci.trpm.hclab ii. 192.168.5.11 tele-adco.trpm.hclab iii. 192.168.5.13 tele-bg.trpm.hclab iv. 192.168.5.14 tele-gw1.trpm.hclab v. 192.168.21.10 tele-gw2.trpm.hclab vi. 38.142.224.131 docker.onclave.net

NIST SP 1800-30C: Securing Telehealth Remote Patient Monitoring Ecosystem

159

b. Save the file and exit. 3. Run the command nano /etc/network/interfaces a. Edit the Interfaces file to include: i. iface ens192 inet static This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

1. address 192.68.5.12 2. netmask 255.255.255.0 3. gateway 192.168.5.1 4. dns-nameservers 192.168.1.10 b. Save the file and exit. 4. Run the command git clone https://github.com/Onclave-Networks/orch.git 5. Navigate to the /home/onclave/orch directory. 6. Run the command chmod +x *.sh 7. Run the command ./go.sh and fill out the following information: a. What will be the hostname for your orchestrator?: tele-orch b. What will be the domain name for your orchestrator?: trpm.hclab c. Enter the deviceʼs public NIC: ens192 d. What is the Blockchain environment?: tele-bci e. Will system need TPM Emulator? (yes/no): yes f.

What is the docker image for the Orchestrator Service?: docker.onclave.net/orchestratorservice:1.1.0- nccoe-tele-orch

8. Reboot the Orchestrator server. 9. Using a web browser, navigate to https://tele-orch.trpm.hclab. 10. Click Verify. 11. Provide the following information (created when making the bundle in the Admin Console): a. Software ID b. Password

NIST SP 1800-30C: Securing Telehealth Remote Patient Monitoring Ecosystem

160

c. PIN 12. Provide the following information to create a superuser account: a. First Name: ***** b. Last Name: ***** This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

c. Username: *****@email.com d. Password: ******** e. Organization Name: Telehealth Lab Create a Customer in the Orchestrator 1. Using a web browser, navigate to https://tele-orch.trpm.hclab. 2. Click Customers. 3. Click the plus symbol. 4. Under Attributes > Customer Name, enter Telehealth Lab. 5. Click Create. Create a Secure Enclave Once each Onclave device has been transferred to the Orchestrator, it will show up in the Orchestrator’s web GUI. From here, the secure enclave can be created with the following steps: 1. Using a web browser, navigate to https://tele-orch.trpm.hclab. 2. Click Secure Enclaves. 3. Click the plus symbol. 4. Under General, provide the following information: a. Secure Enclave name: TeleHealth Secure Enclave b. Customer: Telehealth Lab c. Sleeve ID: 51 5. Under Subnets, provide a Network Address (CIDR notation) of 192.168.50.0/24. 6. Under Session Key, provide a Lifespan (minutes) of 60. 7. Click Create.

NIST SP 1800-30C: Securing Telehealth Remote Patient Monitoring Ecosystem

161

Prepare the Bridge for Inclusion in the Secure Enclave 1. Using a web browser, navigate to https://tele-orch.trpm.hclab. 2. Click Devices. 3. Select the bridge and provide the following information: This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

a. Device Name: tele-bg b. Customer: Telehealth Lab c. Secure Enclaves: Not assigned to any Secure Enclave d. State: Orchestrator Acquired e. Secure tunnel port number: 820 f.

Private interface IP address undefined: checked

4. Click Save. Prepare the Telehealth Gateway for Inclusion in the Secure Enclave 1. Using a web browser, navigate to https://tele-orch.trpm.hclab. 2. Click Devices. 3. Select the bridge and provide the following information: a. Device Name: tele-gw1 b. Customer: Telehealth Lab c. Secure Enclaves: Not assigned to any Secure Enclave d. State: Orchestrator Acquired e. Secure tunnel port number: 820 f.

Private interface IP address undefined: checked

4. Click Save. Prepare the Home Gateway for Inclusion in the Secure Enclave 1. Using a web browser, navigate to https://tele-orch.trpm.hclab. 2. Click Devices. 3. Select the bridge and provide the following information:

NIST SP 1800-30C: Securing Telehealth Remote Patient Monitoring Ecosystem

162

a. Device Name: tele-gw2 b. Customer: Telehealth Lab c. Secure Enclaves: Not assigned to any Secure Enclave d. State: Orchestrator Acquired This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

e. Secure tunnel port number: 820 f.

Private interface IP address undefined: checked

4. Click Save. Establish the Secure Enclave Once the secure enclave has been created and each Onclave device has been configured with a name and customer, the secure enclave can be established with the following steps: 1. Using a web browser, navigate to https://tele-orch.trpm.hclab. 2. Click Secure Enclaves. 3. Click the edit symbol for the previously created secure enclave. 4. Under Topology, click Add a Bridge. 5. Select tele-bg. 6. Click Add. 7. Click Add a Gateway. 8. Select tele-gw1. 9. Click Add. 10. Click Add a Gateway. 11. Select tele-gw2. 12. Click Add. 13. Under Topology Controls, toggle on Approve topology. 14. Click Save Changes. 15. Click Devices. 16. Refresh the Devices page until each device is labeled as Topology Approved.

NIST SP 1800-30C: Securing Telehealth Remote Patient Monitoring Ecosystem

163

17. Click Secure Enclaves. 18. Click the edit symbol for the previously created secure enclave. 19. Under Topology, toggle on Trust All Devices. 20. Click Save Changes. This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

21. Click Devices. 22. Refresh the Devices page until each device is labeled as Secured. Onclave SecureIoT Bridge Appliance Information CPU: 4 RAM: 8 GB Storage: 32 GB (Thick Provision) Network Adapter 1: VLAN 1317 Network Adapter 2: VLAN 1319 Operating System: Debian Linux 9.11 Onclave SecureIoT Bridge Appliance Configuration Guide 1. Run the command scp onclave@192.168.5.10:/home/onclave/blockchain/certs/telebci.trpm.hclab.crt /root/certs

2. Run the command nano /etc/hosts a. Edit the Hosts file to include the IP address and domain name of each Onclave device, as well as Onclave’s docker server. This will include: i. 192.168.5.10 tele-bci.trpm.hclab ii. 192.168.5.11 tele-adco.trpm.hclab iii. 192.168.5.12 tele-orch.trpm.hclab iv. 192.168.5.14 tele-gw1.trpm.hclab v. 192.168.21.10 tele-gw2.trpm.hclab vi. 38.142.224.131 docker.onclave.net 3. Run the command nano /etc/network/interfaces

NIST SP 1800-30C: Securing Telehealth Remote Patient Monitoring Ecosystem

164

a. Edit the Interfaces file to include: i. iface ens192 inet static 1. address 192.68.5.13 2. netmask 255.255.255.0 This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

3. gateway 192.168.5.1 4. dns-nameservers 192.168.1.10 ii. iface ens224 inet static b. Save the file and exit. 4. Run the command git clone https://github.com/Onclave-Networks/bridge.git 5. Navigate to the /home/onclave/bridge directory. 6. Run the command chmod +x *.sh 7. Run the command ./go.sh a. What will be the hostname for your bridge?: tele-bg b. What will be the domain name for your bridge?: trpm.hclab c. Enter the deviceʼs public NIC: ens192 d. Enter the device’s private NIC: ens224 e. What is the Blockchain environment?: tele-bci f.

Will system need TPM Emulator? (yes/no): yes

g. What is the docker image for the Bridge Service?: docker.onclave.net/bridgeservice:1.1.0- nccoe-tele-bg 8. Reboot the Bridge server. Onclave SecureIoT Telehealth Gateway Appliance Information CPU: 2 RAM: 8 GB Storage: 16 GB Network Adapter 1: VLAN 1317

NIST SP 1800-30C: Securing Telehealth Remote Patient Monitoring Ecosystem

165

Network Adapter 2: VLAN 1349 Operating System: Debian Linux 9.11 Onclave SecureIoT Telehealth Gateway Appliance Configuration Guide 1. Run the command scp onclave@192.168.5.10:/home/onclave/blockchain/certs/telebci.trpm.hclab.crt /root/certs

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

2. Run the command nano /etc/hosts a. Edit the Hosts file to include the IP address and domain name of each Onclave device, as well as Onclave’s docker server. This will include: i. 192.168.5.10 tele-bci.trpm.hclab ii. 192.168.5.11 tele-adco.trpm.hclab iii. 192.168.5.12 tele-orch.trpm.hclab iv. 192.168.5.13 tele-bg.trpm.hclab v. 192.168.21.10 tele-gw2.trpm.hclab vi. 38.142.224.131 docker.onclave.net 3. Run the command nano /etc/network/interfaces a. Edit the Interfaces file to include: i. iface enp3s0 inet static 1. address 192.168.5.14 2. netmask 255.255.255.0 3. gateway 192.168.5.1 4. dns-nameservers 192.168.1.10 ii. iface ens224 inet dhcp b. Save the file and exit. 4. Run the command git clone https://github.com/Onclave-Networks/gateway.git 5. Navigate to the /home/onclave/gateway directory. 6. Run the command chmod +x *.sh

NIST SP 1800-30C: Securing Telehealth Remote Patient Monitoring Ecosystem

166

7. Run the command ./go.sh a. What will be the hostname for your gateway?: tele-gw1 b. What will be the domain name for your gateway?: trpm.hclab c. Enter the deviceʼs public NIC: enp3s0 This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

d. Enter the deviceʼs private NIC: enp2s0 e. What is the Blockchain environment?: tele-bci f.

Will system need TPM Emulator? (yes/no): no

g. What is the docker image for the Gateway Service?: docker.onclave.net/ gatewayservice:1.1.0- nccoe-tele-gw 8. Reboot the Gateway server. Onclave SecureIoT Home Wi-Fi Gateway Appliance Information CPU: 1 RAM: 4 GB Storage: 16 GB Network Adapter 1: VLAN 1332 Network Adapter 2: VLAN 1350 (Wi-Fi) Operating System: Debian Linux 9.11 Onclave SecureIoT Home Wi-Fi Gateway Appliance Configuration Guide 1. Run the command scp onclave@192.168.5.10:/home/onclave/blockchain/certs/telebci.trpm.hclab.crt /root/certs

2. Run the command nano /etc/hosts a. Edit the Hosts file to include the IP address and domain name of each Onclave device, as well as Onclave’s docker server. This will include: i. 192.168.5.10 tele-bci.trpm.hclab ii. 192.168.5.11 tele-adco.trpm.hclab iii. 192.168.5.12 tele-orch.trpm.hclab iv. 192.168.5.13 tele-bg.trpm.hclab

NIST SP 1800-30C: Securing Telehealth Remote Patient Monitoring Ecosystem

167

v. 192.168.5.14 tele-gw1.trpm.hclab vi. 38.142.224.131 docker.onclave.net 3. Run the command nano /etc/network/interfaces a. Edit the Interfaces file to include: This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

i. iface enp3s0 inet static 1. address 192.168.21.10 2. netmask 255.255.255.0 3. gateway 192.168.21.1 4. dns-nameservers 192.168.1.10 ii. iface br0 inet static 1. bridge_ports br51 wlp5s0 iii. iface wlp5s0 inet manual b. Save the file and exit. 4. Run the command git clone https://github.com/Onclave-Networks/hostapd-29.git 5. Navigate to the /home/onclave/hostapd-29 directory. 6. Run the command chmod +x *.sh 7. Run the command ./hostapd-29.sh 8. Navigate to the /home/onclave directory. 9. Run the command git clone https://github.com/Onclave-Networks/hostapd-client.git 10. Navigate to the /home/onclave/hostapd-client directory. 11. Run the command chmod +x *.sh 12. Run the command ./hostapd-client.sh 13. Navigate to the /home/onclave directory. 14. Run the command git clone https://github.com/Onclave-Networks/gateway.git 15. Navigate to the /home/onclave/gateway directory. 16. Run the command chmod +x *.sh

NIST SP 1800-30C: Securing Telehealth Remote Patient Monitoring Ecosystem

168

17. Run the command ./go.sh a. What will be the hostname for your gateway?: tele-gw2 b. What will be the domain name for your gateway?: trpm.hclab c. Enter the deviceʼs public NIC: enp3s0 This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

d. Enter the deviceʼs private NIC: wlp5s0 e. What is the Blockchain environment?: tele-bci f.

Will system need TPM Emulator? (yes/no): no

g. What is the docker image for the Gateway Service?: docker.onclave.net/ gatewayservice:1.1.0- nccoe-tele-gw Reboot the Gateway server.

NIST SP 1800-30C: Securing Telehealth Remote Patient Monitoring Ecosystem

169

Appendix A

List of Acronyms

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

AD

Active Directory

CPU

Central Processing Unit

DC

Domain Controller

DHCP

Dynamic Host Configuration Protocol

DNS

Domain Name System

FMC

Firepower Management Center

FTD

Firepower Threat Defense

GB

Gigabyte

HDO

Healthcare Delivery Organization

HIS

Health Information System

IP

Internet Protocol

ISO

International Organization for Standardization

IT

Information Technology

NAT

Network Address Translation

NCCoE

National Cybersecurity Center of Excellence

NIST

National Institute of Standards and Technology

OVA

Open Virtual Appliance or Application

PACS

Picture Archiving and Communication System

RAM

Random Access Memory

RPM

Remote Patient Monitoring

SFC

Stealthwatch Flow Collector

SIEM

Security Information and Event Management

SMC

Stealthwatch Management Center

SP

Special Publication

TB

Terabyte

URL

Uniform Resource Locator

vCPU

Virtual Central Processing Unit

VLAN

Virtual Local Area Network

VM

Virtual Machine

XDR

Extended Detection and Response

NIST SP 1800-30C: Securing Telehealth Remote Patient Monitoring Ecosystem

170

Appendix B

References

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-30.

[1]

J. Cawthra et al., Securing Picture Archiving and Communication System (PACS), National Institute of Standards and Technology (NIST) Special Publication 1800-24, NIST, Gaithersburg, Md., Dec. 2020. Available: https://nvlpubs.nist.gov/nistpubs/SpecialPublications/NIST.SP.180024.pdf.

[2]

Framework for Improving Critical Infrastructure Cybersecurity, Version 1.1, NIST, Gaithersburg, Md., Apr. 16, 2018. Available: https://nvlpubs.nist.gov/nistpubs/CSWP/NIST.CSWP.04162018.pdf.

[3]

Tenable. Managed by Tenable.sc. [Online]. Available: https://docs.tenable.com/nessus/8_10/Content/ManagedbyTenablesc.htm.

[4]

Microsoft. Install Active Directory Domain Services (Level 100). [Online]. Available: https://docs.microsoft.com/en-us/windows-server/identity/ad-ds/deploy/install-activedirectory-domain-services--level-100-#to-install-ad-ds-by-using-server-manager.

[5]

Cisco. Cisco Firepower Management Center Virtual Getting Started Guide. [Online]. Available: https://www.cisco.com/c/en/us/td/docs/security/firepower/quick_start/fmcv/fpmcvirtual/fpmc-virtual-vmware.html.

[6]

Cisco. Cisco Firepower Threat Defense Virtual for VMware Getting Started Guide: Deploy the Firepower Threat Defense Virtual. [Online]. Available: https://www.cisco.com/c/en/us/td/docs/security/firepower/quick_start/vmware/ftdv/ftdvvmware-gsg/ftdv-vmware-deploy.html.

[7]

Cisco. Cisco Firepower Threat Defense Virtual for VMware Getting Started Guide: Managing the Firepower Threat Defense Virtual with the Firepower Management Center. [Online]. Available: https://www.cisco.com/c/en/us/td/docs/security/firepower/quick_start/vmware/ftdv/ftdvvmware-gsg/ftdv-vmware-fmc.html.

[8]

Cisco. Cisco Stealthwatch Installation and Configuration Guide 7.1. [Online]. Available: https://www.cisco.com/c/dam/en/us/td/docs/security/stealthwatch/system_installation_config uration/SW_7_1_Installation_and_Configuration_Guide_DV_1_0.pdf.

[9]

Cisco. Deploy VAs in VMware. [Online]. Available: https://docs.umbrella.com/deploymentumbrella/docs/deploy-vas-in-vmware.

NIST SP 1800-30C: Securing Telehealth Remote Patient Monitoring Ecosystem

171

Related documents

Record · ID 2839 · SHA-256 610889e351353e4b
Retrieved via Conceptio: every document is proof-bundled with source, license, and retrieval metadata.
Bring this data into your agent: Connect via MCP or API · 20 free credits to start · no card required