ConceptioArchiveNCBI PubMed Central
NCBI PubMed Centralopen access

Event-by-Event Continuous Respiratory Motion Correction for Dynamic PET Imaging.

Yu Y et al. · ncbi_pmc
NCBI PubMed Central · Papers · License: Open Access
Open Source ↗Direct PDF ↓
computerscienceeducation
computer science education

Skip to main content An official website of the United States government Here's how you know Here's how you know Official websites use .gov A .gov website belongs to an official government organization in the United States. Secure .gov websites use HTTPS A lock ( Lock Locked padlock icon ) or https:// means you've safely connected to the .gov website. Share sensitive information only on official, secure websites. Search Log in Dashboard Publications Account settings Log out Search… Search NCBI Primary site navigation Search Logged in as: Dashboard Publications Account settings Log in Search PMC Full-Text Archive Search in PMC Journal List User Guide PERMALINK Copy As a library, NLM provides access to scientific literature. Inclusion in an NLM database does not imply endorsement of, or agreement with, the contents by NLM or the National Institutes of Health. Learn more: PMC Disclaimer | PMC Copyright Notice J Nucl Med . Author manuscript; available in PMC: 2026 Apr 12. Published in final edited form as: J Nucl Med. 2016 Feb 23;57(7):1084–1090. doi: 10.2967/jnumed.115.167676 Search in PMC Search in PubMed View in NLM Catalog Add to search Event-by-Event Continuous Respiratory Motion Correction for Dynamic PET Imaging Yunhan Yu Yunhan Yu 1 Department of Diagnostic Radiology, Yale University, New Haven, Connecticut 2 Department of Engineering Physics, Key Laboratory of Particle and Radiation Imaging (Tsinghua University), Ministry of Education, Beijing, China Find articles by Yunhan Yu 1, 2 , Chung Chan Chung Chan 1 Department of Diagnostic Radiology, Yale University, New Haven, Connecticut Find articles by Chung Chan 1 , Tianyu Ma Tianyu Ma 2 Department of Engineering Physics, Key Laboratory of Particle and Radiation Imaging (Tsinghua University), Ministry of Education, Beijing, China Find articles by Tianyu Ma 2 , Yaqiang Liu Yaqiang Liu 2 Department of Engineering Physics, Key Laboratory of Particle and Radiation Imaging (Tsinghua University), Ministry of Education, Beijing, China Find articles by Yaqiang Liu 2 , Jean-Dominique Gallezot Jean-Dominique Gallezot 1 Department of Diagnostic Radiology, Yale University, New Haven, Connecticut Find articles by Jean-Dominique Gallezot 1 , Mika Naganawa Mika Naganawa 1 Department of Diagnostic Radiology, Yale University, New Haven, Connecticut Find articles by Mika Naganawa 1 , Olivia J Kelada Olivia J Kelada 3 Department of Therapeutic Radiology, Yale University School of Medicine, New Haven, Connecticut 4 Department of Medical Physics in Radiation Oncology, German Cancer Research Center, Heidelberg, Germany Find articles by Olivia J Kelada 3, 4 , Mary Germino Mary Germino 5 Department of Biomedical Engineering, Yale University School of Medicine, New Haven, Connecticut Find articles by Mary Germino 5 , Albert J Sinusas Albert J Sinusas 1 Department of Diagnostic Radiology, Yale University, New Haven, Connecticut 6 Department of Internal Medicine, Yale University School of Medicine, New Haven, Connecticut Find articles by Albert J Sinusas 1, 6 , Richard E Carson Richard E Carson 1 Department of Diagnostic Radiology, Yale University, New Haven, Connecticut 5 Department of Biomedical Engineering, Yale University School of Medicine, New Haven, Connecticut Find articles by Richard E Carson 1, 5 , Chi Liu Chi Liu 1 Department of Diagnostic Radiology, Yale University, New Haven, Connecticut 5 Department of Biomedical Engineering, Yale University School of Medicine, New Haven, Connecticut Find articles by Chi Liu 1, 5 Author information Article notes Copyright and License information 1 Department of Diagnostic Radiology, Yale University, New Haven, Connecticut 2 Department of Engineering Physics, Key Laboratory of Particle and Radiation Imaging (Tsinghua University), Ministry of Education, Beijing, China 3 Department of Therapeutic Radiology, Yale University School of Medicine, New Haven, Connecticut 4 Department of Medical Physics in Radiation Oncology, German Cancer Research Center, Heidelberg, Germany 5 Department of Biomedical Engineering, Yale University School of Medicine, New Haven, Connecticut 6 Department of Internal Medicine, Yale University School of Medicine, New Haven, Connecticut ✉ For correspondence or reprints contact: Chi Liu, Department of Diagnostic Radiology, Yale University, P.O. Box 208048, New Haven, CT 06520-8048. [email protected] Issue date 2016 Jul. PMC Copyright notice PMCID: PMC13069555  NIHMSID: NIHMS2147603  PMID: 26912437 The publisher's version of this article is available at J Nucl Med Abstract Existing respiratory motion-correction methods are applied only to static PET imaging. We have previously developed an event-by-event respiratory motion-correction method with correlations between internal organ motion and external respiratory signals (INTEX). This method is uniquely appropriate for dynamic imaging because it corrects motion for each time point. In this study, we applied INTEX to human dynamic PET studies with various tracers and investigated the impact on kinetic parameter estimation. Methods: The use of 3 tracers—a myocardial perfusion tracer, 82 Rb ( n = 7); a pancreatic β-cell tracer, 18 F-FP(+)DTBZ ( n = 4); and a tumor hypoxia tracer, 18 F-fluoromisonidazole ( 18 F-FMISO) ( n = 1)—was investigated in a study of 12 human subjects. Both rest and stress studies were performed for 82 Rb. The Anzai belt system was used to record respiratory motion. Three-dimensional internal organ motion in high temporal resolution was calculated by INTEX to guide event-by-event respiratory motion correction of target organs in each dynamic frame. Time–activity curves of regions of interest drawn based on end-expiration PET images were obtained. For 82 Rb studies, K 1 was obtained with a 1-tissue model using a left-ventricle input function. Rest–stress myocardial blood flow (MBF) and coronary flow reserve (CFR) were determined. For 18 F-FP(+)DTBZ studies, the total volume of distribution was estimated with arterial input functions using the multilinear analysis 1 method. For the 18 F-FMISO study, the net uptake rate K i was obtained with a 2-tissue irreversible model using a left-ventricle input function. All parameters were compared with the values derived without motion correction. Results: With INTEX, K 1 and MBF increased by 10% ± 12% and 15% ± 19%, respectively, for 82 Rb stress studies. CFR increased by 19% ± 21%. For studies with motion amplitudes greater than 8 mm ( n = 3), K 1 , MBF, and CFR increased by 20% ± 12%, 30% ± 20%, and 34% ± 23%, respectively. For 82 Rb rest studies, INTEX had minimal effect on parameter estimation. The total volume of distribution of 18 F-FP(+)DTBZ and K i of 18 F-FMISO increased by 17% ± 6% and 20%, respectively. Conclusion: Respiratory motion can have a substantial impact on dynamic PET in the thorax and abdomen. The INTEX method using continuous external motion data substantially changed parameters in kinetic modeling. More accurate estimation is expected with INTEX. Keywords: respiratory motion correction, dynamic PET imaging, INTEX Respiratory motion is a major challenge in PET imaging, leading to image quality degradation including blurring and contrast reduction ( 1 ), as well as quantitative errors in regional radioactivity concentration measurements ( 2 ), which can lead to inaccuracies in tumor delineation and errors in clinical diagnoses ( 3 ). In dynamic PET imaging, which aims to extract physiologically relevant information from multiple time frames instead of 1 static image, respiratory motion could result in quantitative errors in each individual time frame. Moreover, irregular breathing patterns and amplitude variations during the dynamic scan may lead to frame-dependent motion blurring, further confounding parameter estimation from kinetic modeling. In cardiac PET, the estimation of coronary flow reserve (CFR) requires 2 dynamic PET scans, one at rest and the other during pharmacologic stress. When vasodilators are administered, the patients’ breathing pattern can change substantially. As shown in Figure 1 , the amplitude of respiratory motion during the stress scan is substantially larger than that during the rest scan for the same subject. Different amounts of motion blurring occur in association with rest and stress scans and can lead to errors in myocardial blood flow (MBF) quantification and confound the assessment of CFR. Therefore, respiratory motion correction (MC) can be critical for dynamic PET imaging. FIGURE 1. Open in a new tab Internal motion displacement of myocardium caused by respiration for 1 subject during both rest and regadenosine-induced stress imaging with 82 Rb. Numerous methods have been proposed to compensate for respiratory motion in static PET imaging ( 4 ). With respiratory motion tracked by external devices or motion information extracted from data-driven methods, MC is typically conducted by gating strategies ( 5 ), image-based registration ( 6 ), or motion-compensated image reconstruction ( 7 ). Respiratory gating is the most common correction approach in static PET imaging. However, with gated dynamic imaging, each reconstructed image has higher image noise as only a small fraction of counts is allocated to each frame ( 8 ). When all of the detected events are used, registration of dynamic gated images into motion-compensated dynamic images is challenging especially for images of early frames. Those early images between 0 and 3 min may demonstrate rapid changes in the radiotracer distribution and fewer visible structures. Reliable motion vectors typically can be estimated only from delayed gated images. The same challenge holds for motion-compensated image reconstruction. We have previously developed an MC method using internal-external (INTEX) motion correlation ( 9 , 10 ) that is integrated with a motion-compensation ordered-subsets expectation maximization list-mode algorithm for resolution-recovery reconstruction (MOLAR) ( 11 , 12 ). This method performs continuous respiratory MC on an event-by-event basis, thus is capable of correcting respiratory motion in dynamic imaging. We have applied this approach to static PET images in previous studies ( 9 , 10 ). In this study, we applied this INTEX method to 12 dynamic human PET studies with 3 different tracers and investigated the effects on quantitation of kinetic parameters. MATERIALS AND METHODS Overview of INTEX MC A brief overview of INTEX is given here, although the details of the methodology have been previously published ( 9 , 10 ). In this method, we first derived linear correlations between the mean displacements of the 1-dimensional external respiratory trace acquired by the Anzai system (Anzai Medical) for each gate and the centroid of an internal target organ (e.g., heart, tumor) derived from gated images in 3 dimensions. On the basis of the correlations, a continuous internal motion file was then generated by converting the entire external trace into a 3-dimensional (3D) transformation matrix with high temporal resolution (≥40 Hz) to guide event-by-event respiratory MC. This is accomplished by rigidly relocating the line of response of each event in MOLAR reconstruction. The INTEX approach corrects respiratory motion using all detected events without increasing image noise. The event-by-event MC can effectively eliminate intragate motion caused by both intercycle and intracycle variations and is uniquely capable of correcting frame-dependent motion for dynamic PET dataset. Experiments and Data Acquisition To comprehensively evaluate the proposed INTEX approach for respiratory MC of dynamic PET images, 12 human subjects were imaged using 3 different radiotracers with different clinical tasks. All studies were approved by the Yale University Human Investigation Committee and Radiation Safety Committee. Seven healthy subjects were included for cardiac dynamic PET imaging with 82 Rb, with the goal of quantification of MBF and determination of CFR ( 13 ). Both rest and regadenoson-induced stress scans were acquired. Vasodilation was induced with a 0.4-mg dose of regadenoson, injected over 30 s, approximately 1 min before the 82 Rb infusion was initiated using a CardioGen-82 infusion system (Bracco Diagnostics) with an infusion rate of 50 mL/min. The average injected 82 Rb dose was 670 ± 67 MBq. For attenuation correction, a noncontrast low-dose CT scan was obtained before the rest PET scan, and another noncontrast CT scan was obtained immediately after the stress PET scan. List-mode PET data acquired over the first 4 min after injection were reconstructed and analyzed for kinetic modeling. Abdominal PET imaging studies were acquired in 4 subjects injected with 18 F-labeled 9-fluoropropyl-(+)- 11 C-dihydrotetrabenazine ( 18 F-FP(+)DTBZ), a radiotracer that binds to the vesicular monoamine transporter-2 in β-cells in the pancreas ( 14 ). These subjects were imaged twice over a 240-min period after injection. The first PET scan was acquired for a 2-h period. After a 30-min break, during which the subjects rested, a second 90-min scan was acquired. The average injected dose was 224 ± 60 MBq. To provide an input function, serial arterial blood samples were collected for determination of metabolites by high-performance liquid chromatography. CT data were acquired before each PET scan for attenuation correction. One patient with non–small cell lung cancer underwent PET imaging of the chest after injection of 180 MBq of 18 F-fluoromisonidazole ( 18 F-FMISO), a hypoxia-targeted radiotracer ( 15 ). Two PET images were acquired over 180 min after injection. The first scan was acquired over 120 min and was followed by a second 30-min scan after a 30-min break. CT data were acquired before each PET scan. Imaging Protocol All PET data were acquired in list mode on a 3D scanner Biograph mCT; Siemens) ( 16 ). For each subject, the first PET scan began shortly before the radiotracer injection to capture the early phase of the tracer kinetics. External respiratory motion was tracked by the Anzai belt system, which was attached to the patients’ lower abdomen. The respiratory trace was first recorded at 40 Hz for subjects (subjects 4 and 7–12) and then improved to 50 Hz (subjects 1–3 and 5) after a software upgrade. INTEX MC for Dynamic PET 3D Internal-External Correlation. The relative amplitude of the Anzai respiratory waveform was reset at the beginning of each PET scan. Therefore, internal-to-external correlations were built separately for each individual PET acquisition in each subject. Taking the 18 F-FP(+)DTBZ PET studies as an example, 2 different correlations were generated. One correlation was generated for the first 2-h scan and a second for the follow-up 90-min scan. If the Anzai system was restarted during a scan for any reason, for example, because of the need to readjust the belt to accommodate for drift in the breathing pattern, the correlation was also rebuilt from that time point. Gated 82 Rb PET images were reconstructed from data acquired between 2 and 6 min after injection. For generation of gated 18 F-FP(+)DTBZ and 18 F-FMISO images, the first 30 min of data of each PET scan were used. All gated images were reconstructed using the previously published point-spread function and time-of-flight ordered-subsets expectation maximization method ( 17 ) with 2 iterations and 30 subsets using 2 × 2 × 2 mm voxels. For every gated PET image of the same subject, the matched CT image was used for attenuation correction, as explained in the next section. Using a previously reported level-set method ( 18 ) to segment target organs (subjects 1–7, myocardium; subjects 8–11, pancreas; subject 12, tumor in lung) from gated images, we established linear correlations between internal organ motion and measured external motion as described above. The correlations extracted from each scan were then applied to each list-mode file. A pilot study (described in the supplemental data [available at http://jnm.snmjournals.org ]) indicated that the difference in the impact of correlation changes for INTEX within 1 scan was small, though additional investigations may be warranted. The internal motion amplitudes of the target organ were also determined by calculating the difference in the center of mass of the organs obtained from the end-inspiration and end-expiration images. Matched Attenuation Correction. All CT attenuation images were acquired during an end-expiration breath hold. For MC, the reference PET frame was also chosen at the end-expiration phase to match with the attenuation-correction scans. Specifically, because each line of response is repositioned to the location at end-expiration during list-mode reconstruction, the matched attenuation correction will be achieved for all events. Manual rigid registration was performed between end-expiration gated PET and attenuation-correction CT images if residual mismatch was observed. Dynamic PET Data Generation. Thirty-two dynamic 82 Rb frames (3 s × 20, 10 s × 6, 20 s × 6), 49 18 F-FP(+)DTBZ frames (30 s × 6, 1 min × 3, 2 min × 2, 5 min × 38), and 39 FMISO frames (30 s × 6, 1 min × 3, 2 min × 2, 5 min × 28) were reconstructed for each subject. All dynamic images with and without INTEX MC were reconstructed by MOLAR with 2 iterations and 30 subsets using 2 × 2 × 2 mm voxels. Corrections for attenuation, scatter, random, and normalization were included in the reconstruction. Three-dimensional regions of interest (ROIs) were defined from end-expiration PET images on the basis of the level-set segmentation. ROIs were also eroded slice by slice manually to the central part of target organ to minimize partial-volume effects. Time–activity curves of the target organ and left ventricle were then obtained. For 82 Rb studies, K 1 values were obtained with a 1-tissue model using a left-ventricle image-derived input function fitted to a 3-parameter model. Rest–stress global MBF and CFR were calculated on the basis of a previously published 82 Rb extraction function equation ( 13 ). K 1 = ( 1 − 0.77 × e − 0.63 ∕ MBF ) × MBF . Eq. 1 CFR = MBF stress MBF rest . Eq. 2 The total volume of distribution ( V T ) of the pancreas was estimated with the arterial input function by the multilinear analysis 1 method for 18 F-FP(+)DTBZ data ( 19 ). A 2-tissue irreversible model was used for 18 F-FMISO with an input function derived from a left-ventricle ROI analysis to estimate the net uptake rate K i from K 1 k 3 /( k 2 + k 3 ) ( 20 ). Statistical Analysis. Percentage differences of the estimated parameters ( K 1 , V T , and K i for the 3 radiotracers) between data with no MC (NMC) and with MC were calculated as: Percentage _ difference = ( P MC P NMC − 1 ) × 100 % . Eq. 3 P = K 1 for subjects 1–7, P = V T for subjects 8–11, and P = K i for subject 12. The K 1 , V T , and K i of all 12 subjects of both NMC and MC analyses were compared using nonparametric paired sign test, an alternative to the paired t test appropriate for non-gaussian data. RESULTS Table 1 shows the demographic information from the subjects in this study. In addition, average respiratory motion amplitudes for the heart, pancreas, and lung tumor ( Table 1 ) were 8.7 ± 3.3 mm (stress)/6.0 ± 1.2 mm (rest), 9.9 ± 2.1 mm, and 5.2 mm, respectively. If multiple scans were obtained for the same subject, the average motion amplitudes across all scans are shown in the table. TABLE 1. Summary of Subject Demographics and Associated Internal Organ Motion Amplitudes Subject no. Tracer Sex Age (y) Weight (kg) Motion amplitude (mm) (stress–rest for 82 Rb) Health status 1 82 Rb F 32 63 13.3/5.8 Healthy 2 82 Rb M 24 95 12.4/6.9 Healthy 3 82 Rb F 32 81 11.3/7.8 Healthy 4 82 Rb F 26 53 7.0/4.1 Healthy 5 82 Rb M 34 71 6.8/7.0 Healthy 6 82 Rb M 31 92 6.2/5.5 Healthy 7 82 Rb M 37 65 4.2/4.6 Healthy 8 18 F-FP(+)DTBZ M 39 62 12.6 Healthy 9 18 F-FP(+)DTBZ M 31 87 10.3 Healthy 10 18 F-FP(+)DTBZ M 27 76 9.7 Diabetic patient 11 18 F-FP(+)DTBZ M 24 74 7.4 Healthy 12 18 F-FMISO M 79 81 5.2 Lung cancer patient Open in a new tab Figure 2 shows representative static images of 82 Rb (2–6 min), 18 F-FP(+DTBZ (150–155 min), and 18 F-FMISO (150–155 min) without and with INTEX MC. MC visually reduced the respiratory blurring and radiotracer cross-talk in the areas indicated by the arrows. For the 82 Rb study, MC resulted in a greater reduction in blurring in the stress scan than in the rest scan. FIGURE 2. Open in a new tab Images reconstructed without and with INTEX MC. (A) Images in sagittal view from 2- to 6-min frames for 82 Rb subject 1 stress study. (B) Images in sagittal view from 2- to 6-min frames for 82 Rb subject 1 rest study. (C) Images in coronal view from 150- to 155-min frames for subject 8 18 F-FP(1)DTBZ study. (D) Images in coronal view from 150- to 155-min frames for subject 12 18 F-FMISO study. Images in each row are displayed on same scale. Figure 3 shows sample time–activity curves of myocardium and left-ventricle blood pool for both MC and NMC analyses in 2 stress 82 Rb studies. For a subject (subject 1 in Table 1 ) with a motion amplitude of 13.3 mm, INTEX changed the shape and values of both tissue and blood-pool time–activity curves ( Fig. 3A ), specifically increasing the later tissue values and decreasing the late blood-pool data. For another subject (subject 7 in Table 1 ) with a small motion amplitude (4.2 mm), the time–activity curve of NMC and MC nearly overlapped. FIGURE 3. Open in a new tab Time–activity curves of myocardium and blood pool of left ventricle for both MC and NMC analyses of subject 1 stress studies (motion amplitude, 13.3 mm) (A) and subject 7 stress studies (motion amplitude, 4.2 mm) (B). Data with MC are displayed in red and data without MC are in black. Triangles and solid line represent activity in myocardium and blood pool, respectively. Dashed line shows myocardial 1-tissue (1T) fitting result. As shown in Table 2 , overall, K 1 increased by 10% ± 12% for stress studies with INTEX. For the subjects (subjects 1–3) with a motion amplitude greater than 8 mm, K 1 increased by 20% ± 12%. For rest studies with smaller motion amplitudes, INTEX MC had minimal effect on K 1 estimation. TABLE 2. K 1 Values for Stress and Rest Studies for Cardiac Subjects Without and With MC As Well As Percentage Difference of K 1 Between MC and NMC Subject no. Motion amplitude (mm) K 1 (mL/min/g) Percentage difference NMC MC Stress Rest Stress Rest Stress Rest Stress Rest 1 13.3 5.8 1.17 0.73 1.61 0.71 38% −4% 2 12.4 6.9 1.68 0.56 1.92 0.57 14% 0% 3 11.3 7.8 1.40 0.80 1.53 0.77 10% −4% 4 7.0 4.1 1.33 0.75 1.37 0.76 3% 2% 5 6.8 7.0 1.08 0.62 1.14 0.59 5% −4% 6 6.2 5.5 0.94 0.57 0.96 0.54 2% −6% 7 4.2 4.6 1.24 0.50 1.22 0.51 −1% 1% Average 8.7 6.0 1.26 0.65 1.39 0.63 10% −2% Open in a new tab Table 3 summarizes the MBF and CFR values ( Eqs. 1 and 2 ) and the changes in these values after MC was applied. MBF increased by 15% K 19% for stress studies with INTEX. For the studies with motion amplitudes greater than 8 mm, MBF increased by 30% ± 20%. TABLE 3. MBF of Both Stress and Rest Studies and CRF for 7 Cardiac Subjects Without and With MC As Well As Percentage Difference of MBF and CFR Between MC and NMC Subject no. MBF (mL/min/g) Percentage difference of MBF CFR Percentage difference of CFR NMC MC Stress Rest Stress Rest Stress Rest NMC MC 1 3.17 1.46 5.02 1.39 58% −5% 2.17 3.61 66% 2 5.31 0.91 6.34 0.94 19% 3% 5.84 6.74 16% 3 4.13 1.71 4.68 1.60 13% −6% 2.42 2.93 21% 4 3.84 1.53 4.00 1.56 4% 2% 2.51 2.56 2% 5 2.81 1.09 3.05 1.00 9% −8% 2.58 3.05 18% 6 2.25 0.94 2.32 0.86 3% −9% 2.39 2.70 13% 7 3.46 0.77 3.38 0.80 −2% 4% 4.49 4.23 −6% Average 3.57 1.20 4.11 1.16 15% −3% 3.20 3.69 19% Open in a new tab CFR increased by 19% ± 21% after MC on average. For subjects 4–7 with motion amplitudes less than 8 mm in both stress and rest studies, the increase on CFR was only 7% ± 9% with MC, whereas for subjects with motion amplitudes greater than 8 mm, the increase was 34% ± 23% on average, with a maximum change of 66%. Figure 4 shows the time–activity curves for 18 F-FP(+)DTBZ subject 8. MC resulted in a higher uptake in the pancreatic time–activity curve. As shown in Table 4 , with INTEX MC, V T for 18 F-FP(+)DTBZ increased by 17% ± 6%. The standard errors of V T , as calculated from the theoretic parameter covariance matrix, were reduced by 28% ± 33% on average. FIGURE 4. Open in a new tab Time–activity curves of pancreas for both MC and NMC analyses of subject 8. Data with MC are displayed in red, and data without MC are in black. Symbols show ROI values, and solid lines give multilinear analysis 1 (MA1) fitting results (t* = 20 min). TABLE 4. V T and K i Values and SD for 18 F-FP(+)DTBZ and FMISO Subjects, Respectively, As Well As Percentage Difference Comparing MC with NMC Subject no. Motion amplitude (mm) NMC, V T MC, V T NMC, K i MC, K i Percentage difference 8 12.6 76.7 ± 4.0 94.8 ± 3.7 24% 9 10.3 159.0 ± 12.7 187.5 ± 11.2 18% 10 9.7 91.5 ± 6.8 97.4 ± 1.6 6% 11 7.4 218.9 ± 5.1 259.1 ± 6.9 18% Average 9.9 136.5 159.7 17% 12 5.2 0.0045 ± 0.0011 0.0054 ± 0.0010 20% Open in a new tab Figure 5 shows time–activity curves of the lung tumor in the 18 F-FMISO study. Internal motion amplitude averaged for every minute over the entire scan duration is also displayed. In the second scan, the average motion amplitude changed from 3.9 (0–120 min) to 6.5 mm (150–180 min), leading to larger increase of time–activity curve values with MC. With INTEX correction, K i for 18 F-FMISO increased by 20% and the SE of K i was reduced by 10%. FIGURE 5. Open in a new tab Time–activity curves of tumor in lung for both MC and NMC analyses of subject 12. Data with MC are displayed in red, and data without MC are in black. Triangles indicate activity in tumor for each dynamic frame. Solid lines show 2-tissue irreversible (2Ti) fitting results. Blue solid line shows respiratory motion amplitude averaged over 1-min intervals calculated from Anzai traces and internal-external correlation. Figure 6 plots the percentage difference of K 1 for 82 Rb, V T for 18 F-FP(+)DTBZ, and K i for 18 F-FMISO in each study between the NMC and MC analysis as a function of internal motion amplitudes. A clear trend can be observed that larger respiratory motion amplitude leads to larger differences in parameter estimates between MC and NMC analyses. The P value of nonparametric alternative to the paired sample t test between the NMC and MC groups of kinetic parameters ( V T , K i , K 1 ) was 0.0076, indicating that MC produced a significant increase in kinetic parameter estimates, consistent with less motion-induced blurring. FIGURE 6. Open in a new tab Percentage difference in K 1 for 82 Rb (black square for rest studies and red circle for stress studies), V T for 18 F-FP(+)DTBZ (blue triangle), and K i for 18 F-FMISO (pink triangle) for all 12 subjects between MC and NMC analyses related to motion amplitude of each subject. DISCUSSION Respiratory motion is an important source of error in PET images. The INTEX method is capable of correcting respiratory motion for dynamic PET, whereas existing MC methods typically are applied only to static PET images. Our results demonstrate that respiratory motion can lead to a significant underestimation of kinetic parameters and INTEX MC can significantly improve the parameter estimation. In long dynamic PET acquisitions, subjects are more likely to have changes in their breathing pattern and amplitude, introducing time-dependent blurring effects that can further confound the parameter estimation. For example, in the 18 F-FMISO study ( Fig. 5 ), the average motion amplitude of the lung tumor changed from 3.9 to 6.5 mm, which led to a greater increase in the values from the tumor time–activity curve in the second scan (150–180 min), resulting in an overall change in shape of the time–activity curve with MC. These results indicated that INTEX MC could be particularly helpful for long dynamic PET studies when subjects demonstrate variation in their breathing pattern. Body motion is another factor that can substantially affect quantification of dynamic images. In our study, the ROIs were manually repositioned in both NMC and MC analyses for dynamic frames, in which a visible mismatch was detected to compensate for body motion. In 82 Rb cardiac studies, the responses to regadenoson varied among study subjects. Motion amplitudes increased from the rest to stress studies for subjects 1–3 by 90%. However, for subjects 4–7, the motion amplitude increase was only 18% on average. The individual motion amplitude differences in response to the vasodilators can confound CFR quantification. For subjects 1–3 with significant respiratory motion, the increase of CFR was 34% on average with MC, and for subjects 4–7 with minimal respiratory motion, the increase was only 7%. The full impact of the changes in a patient’s breathing pattern and the benefit of respiratory MC require further investigation, including the evaluation of other pharmacologic stressors currently used in clinical practice. Compared with PET imaging studies using 18 F-labeled radiotracers, cardiac 82 Rb PET studies have relatively poorer resolution due to a large positron range of 82 Rb. MC generally did not seem to substantially change K 1 and MBF for resting scans. However, for stress scans these changes were substantial, particularly for subjects with motion amplitudes larger than 8 mm. These results indicated that MC is essential for subjects with motion amplitudes greater than 8 mm in 82 Rb cardiac PET studies. In the 18 F-FP(+)DTBZ and 18 F-FMISO studies, MC led to substantially increased parameters ( V T and K i ) for all subjects, indicating the importance of MC in the thorax and abdomen for 18 F-labeled tracers that demonstrate better resolution. One limitation of this study is that no true gold standard parameters were available for validation of the benefit of MC. That being said, considering that uncorrected motion introduces blurring, an increase of radiotracer concentration and alterations in the kinetic parameters ( K 1 , V T , K i ) shown in this study indicates that our proposed MC should provide more accurate parameter estimation. Specifically, because the kinetic parameters all are reflective of the scale of uptake, reductions in absolute levels in the time–activity curves due to uncorrected motion would reduce these kinetic parameters. This same effect was further investigated and confirmed by simulation studies provided in the supplemental data . The INTEX/MOLAR approach used in this study is an event-by-event respiratory MC method that rigidly relocates the line of response of each event in a list-mode image reconstruction framework. However, more complex deformation of target organs with larger size will not be fully corrected by a rigid MC method. Specifically, other tissues or organs with different motion amplitudes and patterns may be blurred by rigid MC. We have developed a nonrigid event-by-event MC method for PET with motion-dependent point-spread function ( 21 ), which more accurately compensates for nonrigid motion. Further investigations are needed to apply this nonrigid INTEX method to dynamic studies. CONCLUSION Respiratory motion can substantially affect parameter estimation in dynamic PET imaging. The INTEX respiratory MC method using continuous external motion signals was shown to substantially change the estimated parameters from dynamic PET of 3 radiotracers with different clinical tasks. More accurate parameter estimation is expected with INTEX MC. Correction for respiratory motion is important for accurate quantification for dynamic PET, particularly for subjects with larger motion amplitudes. Supplementary Material Supplemental_167676 NIHMS2147603-supplement-Supplemental_167676.pdf (1.1MB, pdf) ACKNOWLEDGMENTS We thank Eric Ackah, MD, PhD, and Herman Feringa, MD, for performing the stress testing in the 82 Rb PET imaging. DISCLOSURE The costs of publication of this article were defrayed in part by the payment of page charges. Therefore, and solely to indicate this fact, this article is hereby marked “advertisement” in accordance with 18 USC section 1734. This work was supported by a research contract from Siemens Medical Solutions. This work was also supported by NIH grant 1S10OD010322-01 and by CTSA grant UL1 TR000142 from the National Center for Advancing Translational Science, a component of the National Institutes of Health (NIH). The contents of this study are solely the responsibility of the authors and do not necessarily represent the official view of NIH. No other potential conflict of interest relevant to this article was reported. REFERENCES 1. El Naqa I, Low DA, Bradley JD, Vicic M, Deasy JO. Deblurring of breathing motion artifacts in thoracic PET images by deconvolution methods. Med Phys. 2006;33:3587–3600. [ DOI ] [ PubMed ] [ Google Scholar ] 2. Callahan J, Binns D, Dunn L, Kron T. Motion effects on SUV and lesion volume in 3D and 4D PET scanning. Australas Phys Eng Sci Med. 2011;34:489–495. [ DOI ] [ PubMed ] [ Google Scholar ] 3. Liu C, Pierce LA II, Alessio AM, Kinahan PE. The impact of respiratory motion on tumor quantification and delineation in static PET/CT imaging. Phys Med Biol. 2009;54:7345–7362. [ DOI ] [ PMC free article ] [ PubMed ] [ Google Scholar ] 4. Rahmim A, Rousset O, Zaidi H. Strategies for motion tracking and correction in PET. PET Clin. 2007;2:251–266. [ DOI ] [ PubMed ] [ Google Scholar ] 5. Nehmeh SA, Erdi Y, Pan T, et al. Quantitation of respiratory motion during 4D-PET/CT acquisition. Med Phys. 2004;31:1333–1338. [ DOI ] [ PubMed ] [ Google Scholar ] 6. Fulton RR, Meikle SR, Eberl S, Pfeiffer J, Constable CJ. Correction for head movements in positron emission tomography using an optical motion-tracking system. IEEE Trans Nucl Sci. 2002;49:116–123. [ Google Scholar ] 7. Lamare F, Carbayo ML, Cresson T, et al. List-mode-based reconstruction for respiratory motion correction in PET using non-rigid body transformations. Phys Med Biol. 2007;52:5187–5204. [ DOI ] [ PubMed ] [ Google Scholar ] 8. Li T, Thorndyke B, Schreibmann E, Yang Y, Xing L. Model-based image reconstruction for four-dimensional PET. Med Phys. 2006;33:1288–1298. [ DOI ] [ PubMed ] [ Google Scholar ] 9. Chan C, Jin X, Fung EK, et al. Event-by-event respiratory motion correction for PET with 3D internal-1D external motion correlation. Med Phys. 2013;40:112507. [ DOI ] [ PubMed ] [ Google Scholar ] 10. Liu C, Alessio AM, Kinahan PE. Respiratory motion correction for quantitative PET/CT using all detected events with internal-external motion correlation. Med Phys. 2011;38:2715–2723. [ DOI ] [ PMC free article ] [ PubMed ] [ Google Scholar ] 11. Carson RE, Barker WC, Liow J-S, Johnson C. Design of a motion-compensation OSEM list-mode algorithm for resolution-recovery reconstruction for the HRRT. IEEE Nucl Sci Symp Conf Rec. 2003;5:3281–3285. [ Google Scholar ] 12. Jin X, Chan C, Mulnix T, et al. List-mode reconstruction for the Biograph mCT with physics modeling and event-by-event motion correction. Phys Med Biol. 2013;58:5567–5591. [ DOI ] [ PMC free article ] [ PubMed ] [ Google Scholar ] 13. Lortie M, Beanlands RS, Yoshinaga K, Klein R, DaSilva JN. Quantification of myocardial blood flow with 82 Rb dynamic PET imaging. Eur J Nucl Med Mol Imaging. 2007;34:1765–1774. [ DOI ] [ PubMed ] [ Google Scholar ] 14. Normandin MD, Petersen KF, Ding Y-S, et al. In vivo imaging of endogenous pancreatic β-cell mass in healthy and type 1 diabetic subjects using 18 F-fluoropropyl-dihydrotetrabenazine and PET. J Nucl Med. 2012;53:908–916. [ DOI ] [ PMC free article ] [ PubMed ] [ Google Scholar ] 15. Carlin S, Humm JL. PET of hypoxia: current and future perspectives. J Nucl Med. 2012;53:1171–1174. [ DOI ] [ PubMed ] [ Google Scholar ] 16. Jakoby BW, Bercier Y, Conti M, Casey M, Bendriem B, Townsend D. Physical and clinical performance of the mCT time-of-flight PET/CT scanner. Phys Med Biol. 2011;56:2375–2389. [ DOI ] [ PubMed ] [ Google Scholar ] 17. Martí-Climent J, Prieto E, Domínguez-Prado I, et al. Contribution of time of flight and point spread function modeling to the performance characteristics of the PET/CT Biograph mCT scanner. Rev Esp Med Nucl Imagen Mo (English ed.). 2013;32:13–21. [ DOI ] [ PubMed ] [ Google Scholar ] 18. Chan TF, Vese L. Active contours without edges. IEEE Trans Image Process. 2001;10:266–277. [ DOI ] [ PubMed ] [ Google Scholar ] 19. Naganawa M, Petersen K, Ding Y-S, et al. Comparison of methods for PET quantification of beta cell mass with [ 18 F] FP-(1)-DTBZ [abstract]. J Nucl Med. 2012;53(suppl 1):547. [ Google Scholar ] 20. Thorwarth D, Eschmann SM, Paulsen F, Alber M. A kinetic model for dynamic [ 18 F]-Fmiso PET data to analyse tumour hypoxia. Phys Med Biol. 2005;50:2209–2224. [ DOI ] [ PubMed ] [ Google Scholar ] 21. Chan C, Jian Y, Germino M, Carson R, Liu C. Non-rigid event-by-event motion correction for PET with motion-dependent PSF. Paper presented at: The 2014 IEEE Nuclear Science Symposium and Medical Imaging Conference; November 8–15, 2014; Seattle, WA. [ Google Scholar ] Associated Data This section collects any data citations, data availability statements, or supplementary materials included in this article. Supplementary Materials Supplemental_167676 NIHMS2147603-supplement-Supplemental_167676.pdf (1.1MB, pdf) ACTIONS View on publisher site PDF (1.4 MB) Cite Collections Permalink PERMALINK Copy RESOURCES Similar articles Cited by other articles Links to NCBI Databases Cite Copy Download .nbib .nbib Format: AMA APA MLA NLM Add to Collections Create a new collection Add to an existing collection Name your collection * Choose a collection Unable to load your collection due to an error Please try again Add Cancel Follow NCBI NCBI on X (formerly known as Twitter) NCBI on Facebook NCBI on LinkedIn NCBI on GitHub NCBI RSS feed Connect with NLM NLM on X (formerly known as Twitter) NLM on Facebook NLM on YouTube National Library of Medicine 8600 Rockville Pike Bethesda, MD 20894 Web Policies FOIA HHS Vulnerability Disclosure Help Accessibility Careers NLM NIH HHS USA.gov Back to Top

Record · ID 4113 · SHA-256 28c4886e2ffd4420
Conceptio Open Knowledge Archive — every document is proof-bundled with source, license, and retrieval metadata.