PART 426—GLASS MANUFACTURING POINT SOURCE CATEGORY Authority: Secs. 301, 304 (b) and (c), 306 (b) and (c), 307(c), and 316(b) of the Federal Water Pollution Control Act, as amended; 33 U.S.C. 1251, 1311, 1314, 1316 (b) and (c), 1317(b); 86 Stat. 816 et seq., Source: 39 FR 2565, Jan. 22, 1974, unless otherwise noted. Subpart A—Insulation Fiberglass Subcategory § 426.10 Applicability; description of the insulation fiberglass subcategory. The provisions of this subpart are applicable to discharges resulting from the production of insulation fiberglass in which molten glass is either directly or indirectly made, continuously fiberized and chemically bonded into a wool-like material. § 426.11 Specialized definitions. For the purpose of this subpart: (a) Except as provided below, the general definitions, abbreviations and methods of analysis set forth in 40 CFR part 401 shall apply to this subpart. (b) The term “cullet water” shall mean that water which is exclusively and directly applied to molten glass in order to solidify the glass. (c) The term “advanced air emission control devices” shall mean air pollution control equipment, such as electrostatic precipitators and high energy scrubbers, that are used to treat an air discharge which has been treated initially by equipment including knock-out chambers and low energy scrubbers. § 426.12 Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available. The following limitations establish the quantity or quality of pollutants or pollutant properties which may be discharged by a point source subject to the provisions of this subpart after application of the best practicable control technology currently available: (a) There shall be no discharge of process waste water pollutants to navigable waters, except as permitted in paragraph (b) of this section. (b) The following limitations establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged in process waste water from advanced air emission control devices, when such water cannot be consumed in the process. Effluent characteristic Effluent limitations Maximum for any 1 day Average of daily values for 30 consecutive days shall not exceed— Metric units (kilograms per 1,000 kg of product) Phenol 0.0006 0.0003 COD 0.33 .165 BOD 5 0.024 .012 TSS 0.03 .015 pH ( 1 ( 1 English units (pounds per 1,000 lb. of product) Phenol 0.0006 0.0003 COD 0.33 .165 BOD 5 0.024 .012 TSS 0.03 .015 pH ( 1 ( 1 1 [39 FR 2565, Jan. 22, 1974; 39 FR 4760, Feb. 7, 1974] § 426.13 Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best available technology economically achievable. The following limitations establish the quantity or quality of pollutants or pollutant properties which may be discharged by a point source subject to the provisions of this subpart after application of the best available technology economically achievable: There shall be no discharge of process waste water pollutants to navigable waters. § 426.14 [Reserved] § 426.15 Standards of performance for new sources. The following standards of performance establish the quantity or quality of pollutants or pollutant properties which may be discharged by a new source subject to the provisions of this subpart: There shall be no discharge of process waste water pollutants to navigable waters. § 426.16 Pretreatment standards for new sources. Any new source subject to this subpart that introduces process wastewater pollutants into a publicly owned treatment works must comply with 40 CFR part 403. (a) Applicability. (b) [Reserved] [39 FR 2565, Jan. 22, 1974, as amended at 60 FR 33958, June 29, 1995] § 426.17 Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT). Except as provided in §§ 125.30 through 125.32, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT): The limitations shall be the same as those specified for conventional pollutants (which are defined in § 401.16) in § 426.12 of this subpart for the best practicable control technology currently available (BPT). [51 FR 25000, July 9, 1986] Subpart B—Sheet Glass Manufacturing Subcategory Source: 39 FR 5714, Feb. 14, 1974, unless otherwise noted. § 426.20 Applicability; description of the sheet glass manufacturing subcategory. The provisions of this subpart are applicable to discharges of pollutants resulting from the process in which several mineral ingredients (sand, soda ash, limestone, dolomite, cullen and other ingredients) are mixed, melted in a furnace, and drawn vertically from a melting tank to form sheet glass. § 426.21 Specialized definitions. For the purpose of this subpart: (a) Except as provided below, the general definitions, abbreviations and methods of analysis set forth in 40 CFR part 401 shall apply to this subpart. (b) The term “cullet” shall mean any broken glass generated in the manufacturing process. § 426.22 Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available. Except as provided in §§ 125.30 through 125.32, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available (BPT): There shall be no discharge of process waste water pollutants to navigable waters. [60 FR 33958, June 29, 1995] § 426.23 Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best available technology economically achievable. The following limitations establish the quantity or quality of pollutants or pollutant properties which may be discharged by a point source subject to the provisions of this subpart after application of the best available technology economically achievable: There shall be no discharge of process waste water pollutants to navigable waters. § 426.24 Pretreatment standards for existing sources. Any existing source subject to this subpart that introduces process wastewater pollutants into a publicly owned treatment works must comply with 40 CFR part 403. In addition, the following pretreatment standard establishes the quantity or quality of pollutants or pollutant properties controlled by this section which may be discharged to a publicly owned treatment works by a point source subject to the provisions of this subpart. Pollutant or pollutant property Pretreatment standard pH No limitation. TSS Do. [40 FR 6444, Feb. 11, 1975, as amended at 60 FR 33958, June 29, 1995] § 426.25 Standards of performance for new sources. The following standards of performance establish the quantity or quality of pollutants or pollutant properties which may be discharged by a new source subject to the provisions of this subpart: There shall be no discharge of process waste water pollutants to navigable waters. § 426.26 Pretreatment standards for new sources. Any new source subject to this subpart that introduces process wastewater pollutants into a publicly owned treatment works must comply with 40 CFR part 403. [60 FR 33958, June 29, 1995] § 426.27 Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology. The following limitations establish the quantity or quality of pollutants or pollutant properties, which may be discharged by a point source subject to the provisions of this subpart after application of the best conventional pollutant control technology: There shall be no discharge of process waste water pollutants to navigable waters. [44 FR 50746, Aug. 29, 1979] Subpart C—Rolled Glass Manufacturing Subcategory Source: 39 FR 5714, Feb. 14, 1974, unless otherwise noted. § 426.30 Applicability; description of the rolled glass manufacturing subcategory. The provisions of this subpart are applicable to discharges of pollutants resulting from the process in which several mineral ingredients (sand, soda ash, limestone, dolomite, cullet, and other ingredients) are mixed, melted in a furnace, and cooled by rollers to form rolled glass. § 426.31 Specialized definitions. For the purpose of this subpart: (a) Except as provided below, the general definitions, abbreviations and methods of analysis set forth in 40 CFR part 401 shall apply to this subpart. (b) The term “cullet” shall mean any broken glass generated in the manufacturing process. § 426.32 Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available. Except as provided in §§ 125.30 through 125.32, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available (BPT): There shall be no discharge of process waste water pollutants to navigable waters. [60 FR 33958, June 29, 1995] § 426.33 Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best available technology economically achievable. The following limitations establish the quantity or quality of pollutants or pollutant properties which may be discharged by a point source subject to the provisions of this subpart after application of the best available technology economically achievable: There shall be no discharge of process waste water pollutants to navigable waters. § 426.34 Pretreatment standards for existing sources. Any existing source subject to this subpart that introduces process wastewater pollutants into a publicly owned treatment works must comply with 40 CFR part 403. In addition, the following pretreatment standard establishes the quantity or quality of pollutants or pollutant properties controlled by this section which may be discharged to a publicly owned treatment works by a point source subject to the provisions of this subpart. Pollutant or pollutant property Pretreatment standard pH No limitation. TSS Do. [40 FR 6444, Feb. 11, 1975, as amended at 60 FR 33958, June 29, 1995] § 426.35 Standards of performance for new sources. The following standards of performance establish the quantity or quality of pollutants or pollutant properties which may be discharged by a new source subject to the provisions of this subpart: There shall be no discharge of process waste water pollutants to navigable waters. § 426.36 Pretreatment standards for new sources. Any new source subject to this subpart that introduces process wastewater pollutants into a publicly owned treatment works must comply with 40 CFR part 403. [60 FR 33958, June 29, 1995] § 426.37 Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology. The following limitations establish the quantity or quality of pollutants or pollutant properties, which may be discharged by a point source subject to the provisions of this subpart after application of the best conventional pollutant control technology: There shall be no discharge of process waste water pollutants to navigable waters. [44 FR 50746, Aug. 29, 1979] Subpart D—Plate Glass Manufacturing Subcategory Source: 39 FR 5714, Feb. 14, 1974, unless otherwise noted. § 426.40 Applicability; description of the plate glass manufacturing subcategory. The provisions of this subpart are applicable to discharges of pollutants resulting from the process in which several mineral ingredients (sand, soda ash, limestone, dolomite, cullet and other ingredients) are melted in a furnace, pressed between rollers, and finally ground and polished to form plate glass. § 426.41 Specialized definitions. For the purpose of this subpart: (a) Except as provided below, the general definitions, abbreviations and methods of analysis set forth in 40 CFR part 401 shall apply to this subpart. (b) The term “cullet” shall mean any broken glass generated in the manufacturing process. § 426.42 Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available. Except as provided in §§ 125.30 through 125.32, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available (BPT): Effluent characteristic Effluent limitations Maximum for any 1 day Average of daily values for 30 consecutive days shall not exceed— Metric units (kg/kkg of product) TSS 2.76 .138 pH ( 1 ( 1 English units (lb/ton of product) TSS 5.52 2.76 pH ( 1 ( 1 1 [39 FR 5714, Feb. 14, 1974, as amended at 60 FR 33958, June 29, 1995] § 426.43 [Reserved] § 426.44 Pretreatment standards for existing sources. Any existing source subject to this subpart that introduces process wastewater pollutants into a publicly owned treatment works must comply with 40 CFR part 403. In addition, the following pretreatment standard establishes the quantity or quality of pollutants or pollutant properties controlled by this section which may be discharged to a publicly owned treatment works by a point source subject to the provisions of this subpart. Pollutant or pollutant property Pretreatment standard pH No limitation. TSS Do. [40 FR 6444, Feb. 11, 1975, as amended at 60 FR 33958, June 29, 1995] § 426.45 Standards of performance for new sources. The following standards of performance establish the quantity or quality of pollutants or pollutant properties which may be discharged by a new source subject to the provisions of this subpart: There shall be no discharge of process waste water pollutants to navigable waters. § 426.46 Pretreatment standards for new sources. Any new source subject to this subpart that introduces process wastewater pollutants into a publicly owned treatment works must comply with 40 CFR part 403. [60 FR 33958, June 29, 1995] § 426.47 Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT). Except as provided in §§ 125.30 through 125.32, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT): The limitations shall be the same as those specified for conventional pollutants (which are defined in § 401.16) in § 426.42 of this subpart for the best practicable control technology currently available (BPT). [51 FR 25000, July 9, 1986] Subpart E—Float Glass Manufacturing Subcategory Source: 39 FR 5714, Feb. 14, 1974, unless otherwise noted. § 426.50 Applicability; description of the float glass manufacturing subcategory. The provisions of this subpart are applicable to discharges of pollutants resulting from the process in which several mineral ingredients (sand, soda ash, limestone, dolomite, cullet, and other ingredients) are mixed, melted in a furnace, and floated on a molten tin bath to produce float glass. § 426.51 Specialized definitions. For the purpose of this subpart: (a) Except as provided below, the general definitions, abbreviations and methods of analysis set forth in 40 CFR part 401 shall apply to this subpart. § 426.52 Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available. Except as provided in §§ 125.30 through 125.32, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available (BPT): Effluent characteristic Effluent limitations Maximum for any 1 day Average of daily values for 30 consecutive days shall not exceed— Metric units (q/kkg of product) TSS 2.00 2.00 Oil 1.40 1.40 Phosphorus 0.05 .05 pH ( 1 ( 1 English units (lb/ton of product) TSS 0.0040 0.0040 Oil 0.0028 .0028 Phosphorus 0.0001 .0001 pH ( 1 ( 1 1 [39 FR 5714, Feb. 14, 1974, as amended at 60 FR 33958, June 29, 1995] § 426.53 Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best available technology economically achievable. The following limitations establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a point source subject to the provisions of this subpart after application of the best available technology economically achievable: Effluent characteristic Effluent limitations Maximum for any 1 day Average of daily values for 30 consecutive days shall not exceed— Metric units (g/kg of product) Phosphorus 0.05 .05 English units (lb/ton of product) Phosphorus 0.0001 .0001 [39 FR 5714, Feb. 14, 1974, as amended at 44 FR 50746, Aug. 29, 1979] § 426.54 [Reserved] § 426.55 Standards of performance for new sources. The following standards of performance establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a new source subject to the provisions of this subpart: Effluent characteristic Effluent limitations Maximum for any 1 day Average of daily values for 30 consecutive days shall not exceed— Metric units (g/kkg of product) TSS 0.70 0.70 Oil 1.40 1 .40 Phosphorus 0.05 .05 pH ( 1 ( 1 English units (lb/ton of product) TSS 0.0014 0.0014 Oil 0.0028 .0028 Phosphorus 0.0001 .0001 pH ( 1 ( 1 1 § 426.56 Pretreatment standards for new sources. Any new source subject to this subpart that introduces process wastewater pollutants into a publicly owned treatment works must comply with 40 CFR part 403. [60 FR 33958, June 29, 1995] § 426.57 Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology. Except as provided in §§ 125.30 through 125.32, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT): The limitations shall be the same as those specified for conventional pollutants (which are defined in § 401.16) in § 426.52 of this subpart for the best practicable control technology currently available (BPT). [51 FR 25000, July 9, 1986] Subpart F—Automotive Glass Tempering Subcategory Source: 39 FR 5714, Feb. 14, 1974, unless otherwise noted. § 426.60 Applicability; description of the automotive glass tempering subcategory. The provisions of this subpart are applicable to discharges of pollutants resulting from the processes in which glass is cut and then passed through a series of processes that grind and polish the edges, bend the glass, and then temper the glass to produce side and back windows for automobiles. § 426.61 Specialized definitions. For the purpose of this subpart: (a) Except as provided below, the general definitions, abbreviations and methods of analysis set forth in 40 CFR part 401 shall apply to this subpart. (b) The term “tempering” shall mean the process whereby glass is heated near the melting point and then rapidly cooled to increase its mechanical and thermal endurance. § 426.62 Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available. Except as provided in §§ 125.30 through 125.32, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available (BPT): Effluent characteristic Effluent limitations Maximum for any 1 day Average of daily values for 30 consecutive days shall not exceed— Metric units (q/sq m of product) TSS 1.95 1.22 Oil 0.64 .64 pH ( 1 ( 1 English units (lb/1,060 sq ft of product) TSS 0.40 0.25 Oil 0.13 .13 pH ( 1 ( 1 1 [39 FR 5714, Feb. 14, 1974, as amended at 60 FR 33959, June 29, 1995] § 426.63 [Reserved] § 426.64 Pretreatment standards for existing sources. Any existing source subject to this subpart that introduces process wastewater pollutants into a publicly owned treatment works must comply with 40 CFR part 403. In addition, the following pretreatment standard establishes the quantity or quality of pollutants or pollutant properties controlled by this section which may be discharged to a publicly owned treatment works by a point source subject to the provisions of this subpart. Pollutant or pollutant property Pretreatment standard pH No limitation. Oil Do. TSS Do. [40 FR 6444, Feb. 11, 1975, as amended at 60 FR 33959, June 29, 1995] § 426.65 Standards of performance for new sources. The following standards of performance establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a new source subject to the provisions of this subpart: Effluent characteristic Effluent limitations Maximum for any 1 day Average of daily values for 30 consecutive days shall not exceed— Metric units (q/sq m of product) TSS 0.24 0.24 Oil 0.49 .49 pH ( 1 ( 1 English units (lb/1,000 sq ft of product) TSS 0.05 0.05 Oil 0.10 .10 pH ( 1 ( 1 1 § 426.66 Pretreatment standards for new sources. Any new source subject to this subpart that introduces process wastewater pollutants into a publicly owned treatment works must comply with 40 CFR part 403. [60 FR 33959, June 29, 1995] § 426.67 Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology. Except as provided in §§ 125.30 through 125.32, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT): The limitations shall be the same as those specified for conventional pollutants (which are defined in § 401.16) in § 426.62 of this subpart for the best practicable control technology currently available (BPT). [51 FR 25000, July 9, 1986] Subpart G—Automotive Glass Laminating Subcategory Source: 39 FR 5714, Feb. 14, 1974, unless otherwise noted. § 426.70 Applicability; description of the automotive glass laminating subcategory. The provisions of this subpart are applicable to discharges of pollutants resulting from the processes which laminate a plastic sheet between two layers of glass, and which prepare the glass for lamination such as cutting, bending and washing, to produce automobile windshields. § 426.71 Specialized definitions. For the purpose of this subpart: (a) Except as provided below, the general definitions, abbreviations and methods of analysis set forth in 40 CFR part 401 shall apply to this subpart. § 426.72 Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available. Except as provided in §§ 125.30 through 125.32, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available (BPT): Effluent characteristic Effluent limitations Maximum for any 1 day Average of daily values for 30 consecutive days shall not exceed— Metric units (q/sq m of product) TSS 4.40 4.40 Oil 1.76 1.76 Phosphorus 1.07 1.07 pH ( 1 ( 1 English units (lb/1,000 sq ft of product) TSS 0.90 0.90 Oil 0.36 .36 Phosphorus 0.22 .22 pH ( 1 ( 1 1 [39 FR 5714, Feb. 14, 1974, as amended at 60 FR 33959, June 29, 1995] § 426.73 Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best available technology economically achievable. The following limitations establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a point source subject to the provisions of this subpart after application of the best available technology economically achievable: Effluent characteristic Effluent limitations Maximum for any 1 day Average of daily values for 30 consecutive days shall not exceed— Metric units (q/sq m of products) Phosphorus 0.30 .30 English units (lb/1,000 sq ft of product) Phosphorus 0.06 .06 [39 FR 5714, Feb. 14, 1974, as amended at 44 FR 50746, Aug. 29, 1979] § 426.74 [Reserved] § 426.75 Standards of performance for new sources. The following standards of performance establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a new point source subject to the provisions of this subpart: Effluent characteristic Effluent limitations Maximum for any 1 day Average of daily values for 30 consecutive days shall not exceed— Metric units (q/sq m of product) TSS 0.88 0.88 Oil 1.76 1.76 Phosphorus 0.30 .30 pH ( 1 ( 1 English units (lb/1,000 lb of product) TSS 0.18 0.18 Oil 0.36 .36 Phosphorus 0.06 .06 pH ( 1 ( 1 1 § 426.76 Pretreatment standards for new sources. Any new source subject to this subpart that introduces process wastewater pollutants into a publicly owned treatment works must comply with 40 CFR part 403. [60 FR 33959, June 29, 1995] § 426.77 Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology. Except as provided in §§ 125.30 through 125.32, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT): The limitations shall be the same as those specified for conventional pollutants (which are defined in § 401.16) in § 426.72 of this subpart for the best practicable control technology currently available (BPT). [51 FR 25000, July 9, 1986] Subpart H—Glass Container Manufacturing Subcategory Source: 40 FR 2956, Jan. 16, 1975, unless otherwise noted. § 426.80 Applicability; description of the glass container manufacturing subcategory. The provisions of this subpart are applicable to discharges resulting from the process by which raw materials are melted in a furnace and mechanically processed into glass containers. § 426.81 Specialized definitions. For the purpose of this subpart: (a) Except as provided below, the general definitions, abbreviations and methods of analysis set forth in part 401 of this chapter shall apply to this subpart. (b) The term “furnace pull” shall mean that amount of glass drawn from the glass furnace or furnaces. (c) The term “oil” shall mean those components of a waste water amenable to measurement by the technique or techniques described in the most recent addition of “Standard Methods” for the analysis of grease in polluted waters, waste waters, and effluents, such as “Standard Methods,” 13th Edition, 2nd Printing, page 407. § 426.82 Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available. Except as provided in §§ 125.30 through 125.32, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available (BPT): Effluent characteristic Effluent limitations Maximum for any 1 day Average of daily values for 30 consecutive days shall not exceed— Metric units (g/kkg of furnace pull) Oil 60.0 30.0 TSS 140.0 70.0 pH ( 1 ( 1 English units (lb/1,000 lb of furnace pull) Oil 0.06 0.03 TSS 0.14 0.07 pH ( 1 ( 1 1 [40 FR 2956, Jan. 16, 1975, as amended at 60 FR 33959, June 29, 1995] §§ 426.83-426.84 [Reserved] § 426.85 Standards of performance for new sources. The following standards of performance establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a new source subject to the provisions of this subpart: Effluent characteristic Effluent limitations Maximum for any 1 day Average of daily values for 30 consecutive days shall not exceed— Metric units (g/kkg of furnace pull) Oil 1.6 0.8 TSS 1.6 0.8 pH ( 1 ( 1 English units (lb/1,000 lb of furnace pull) Oil 0.0016 0.0008 TSS 0.0016 0.0008 pH ( 1 ( 1 1 § 426.86 Pretreatment standards for new sources. Any new source subject to this subpart that introduces process wastewater pollutants into a publicly owned treatment works must comply with 40 CFR part 403. In addition, the following pretreatment standard establishes the quantity or quality of pollutants or pollutant properties controlled by this section which may be discharged to a publicly owned treatment works by a new point source subject to the provisions of this subpart. Because of the recognition that animal and vegetable oils can be adequately removed in a publicly owned treatment works, whereas mineral oil may not be readily removed and may pass through untreated, two separate limitations are established. Pollutant or pollutant property Pretreatment standards Maximum for any 1 day Average of daily values for 30 consecutive days shall not exceed— Metric units (g/kkg of furnace pull) Oil (animal and vegetable) ( 1 ( 1 Oil (mineral) 60.0 30.0 TSS ( 1 ( 1 pH ( 1 ( 1 English units (lb/1,000 lb of furnace pull) Oil (animal and vegetable) ( 1 ( 1 Oil (mineral) 0.06 0.03 TSS ( 1 ( 1 pH ( 1 ( 1 1 [40 FR 2956, Jan. 16, 1975, as amended at 60 FR 33959, June 29, 1995] § 426.87 Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology. Except as provided in §§ 125.30 through 125.32, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT): The limitations shall be the same as those specified for conventional pollutants (which are defined in § 401.16) in § 426.82 of this subpart for the best practicable control technology currently available (BPT). [51 FR 25000, July 9, 1986] Subpart I—Machine Pressed and Blown Glass Manufacturing Subcategory [Reserved] Subpart J—Glass Tubing (Danner) Manufacturing Subcategory Source: 40 FR 2957, Jan. 16, 1975, unless otherwise noted. § 426.100 Applicability; description of the glass tubing (Danner) manufacturing subcategory. The provisions of this subpart are applicable to discharges resulting from the process by which raw materials are melted in a furnace and glass tubing mechanically drawn from the furnace horizontally by means of the Danner process, which requires the intermittent quenching of cullet. § 426.101 Specialized definitions. For the purpose of this subpart: (a) Except as provided below, the general definitions, abbreviations and methods of analysis set forth in part 401 of this chapter shall apply to this subpart. (b) The term “furnace pull” shall mean that amount of glass drawn from the glass furnace or furnaces. (c) The term “cullet” shall mean any excess glass generated in the manufacturing process. § 426.102 Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available. Except as provided in §§ 125.30 through 125.32, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available (BPT): Effluent characteristic Effluent limitations Maximum for any 1 day Average of daily values for 30 consecutive days shall not exceed— Metric units (g/kkg of furnace pull) TSS 460.0 230.0 pH ( 1 ( 1 English units (lb/1,000 lb of furnace pull) TSS 0.46 0.23 pH ( 1 ( 1 1 [40 FR 2957, Jan. 16, 1975, as amended at 60 FR 33959, June 29, 1995] §§ 426.103-426.104 [Reserved] § 426.105 Standards of performance for new sources. The following standards of performance establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a new source subject to the provisions of this subpart: Effluent characteristic Effluent limitations Maximum for any 1 day Average of daily values for 30 consecutive days shall not exceed— Metric units (g/kkg of furnace pull) TSS 0.4 0.2 pH ( 1 ( 1 English units (lb/1,000 lb of furnace pull) TSS 0.0004 0.0002 pH ( 1 ( 1 1 § 426.106 Pretreatment standards for new sources. Any new source subject to this subpart that introduces process wastewater pollutants into a publicly owned treatment works must comply with 40 CFR part 403. In addition, the following pretreatment standard establishes the quantity or quality of pollutants or pollutant properties controlled by this section which may be discharged to a publicly owned treatment works by a new point source subject to the provisions of this subpart. Pollutant or pollutant property Pretreatment standard pH No limitation. TSS Do. [40 FR 2957, Jan. 16, 1975, as amended at 60 FR 33959, June 29, 1995] § 426.107 Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology. Except as provided in §§ 125.30 through 125.32, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT): The limitations shall be the same as those specified for conventional pollutants (which are defined in § 401.16) in § 426.102 of this subpart for the best practicable control technology currently available (BPT). [51 FR 25000, July 9, 1986] Subpart K—Television Picture Tube Envelope Manufacturing Subcategory Source: 40 FR 2957, Jan. 16, 1975, unless otherwise noted. § 426.110 Applicability; description of the television picture tube envelope manufacturing subcategory. The provisions of this subpart are applicable to discharges resulting from the process by which raw materials are melted in a furnace and processed into television picture tube envelopes. § 426.111 Specialized definitions. For the purpose of this subpart: (a) Except as provided below, the general definitions, abbreviations and methods of analysis set forth in part 401 of this chapter shall apply to this subpart. (b) The term “furnace pull” shall mean that amount of glass drawn from the glass furnace or furnaces. (c) The term “oil” shall mean those components of a waste water amenable to measurement by the technique or techniques described in the most recent addition of “Standard Methods” for the analysis of grease in polluted waters, waste waters, and effluents, such as “Standard Methods,” 13th Edition, 2nd Printing, page 407. § 426.112 Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available. Except as provided in §§ 125.30 through 125.32, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available (BPT). (The fluoride and lead limitations are applicable to the abrasive polishing and acid polishing waste water streams while the TSS, oil, and pH limitations are applicable to the entire process waste water stream): Effluent characteristic Effluent limitations Maximum for any 1 day Average of daily values for 30 consecutive days shall not exceed— Metric units (g/kkg of furnace pull) Oil 260.0 130.0 TSS 300.0 150.0 Fluoride 140.0 70.0 Lead 39.0 4.5 pH ( 1 ( 1 English units (lb/1,000 lb of furnace pull) Oil 0.26 0.13 TSS 0.30 0.15 Fluoride 0.14 0.07 Lead 0.009 0.0045 pH ( 1 ( 1 1 [40 FR 2957, Jan. 16, 1975, as amended at 60 FR 33959, June 29, 1995] § 426.113 Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best available technology economically achievable. The following limitations establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a point source subject to the provisions of this subpart after application of the best available technology economically achievable. These limitations are applicable to the abrasive polishing and acid polishing waste water streams. Effluent characteristic Effluent limitations Maximum for any 1 day Average of daily values for 30 consecutive days shall not exceed— Metric units (g/kkg of furnace pull) Fluoride 120.0 60.0 Lead 0.9 0.45 English units (lb/1,000 lb of furnace pull) Fluoride 0.12 0.06 Lead 0.0009 0.00045 [44 FR 50747, Aug. 29, 1979] § 426.114 [Reserved] § 426.115 Standards of performance for new sources. The following standards of performance establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a new source subject to the provisions of this subpart (the fluoride and lead limitations are applicable to the abrasive polishing and acid polishing waste water streams while the TSS, oil, and pH limitations are applicable to the entire process waste water stream): Effluent characteristic Effluent limitations Maximum for any 1 day Average of daily values for 30 consecutive days shall not exceed— Metric units (g/kkg of furnace pull) Oil 260.0 130.0 TSS 260.0 130.0 Fluoride 120.0 60.0 Lead 30.9 0.45 pH ( 1 ( 1 English units (lb/1,000 lb of furnace pull) Oil 0.26 0.13 TSS 0.26 0.13 Fluoride 0.12 0.06 Lead 0.0009 0.00045 pH ( 1 ( 1 1 § 426.116 Pretreatment standards for new sources. Any new source subject to this subpart that introduces process wastewater pollutants into a publicly owned treatment works must comply with 40 CFR part 403. In addition, the following pretreatment standard establishes the quantity or quality of pollutants or pollutant properties controlled by this section which may be discharged to a publicly owned treatment works by a new point source subject to the provisions of this subpart. Because of the recognition that animal and vegetable oils can be adequately removed in a publicly owned treatment works, whereas mineral oil may not be readily removed and may pass through untreated, two separate limitations are established. Pollutant or pollutant property Pretreatment standards Maximum for any 1 day Average of daily values for 30 consecutive days shall not exceed— Metric units (g/kkg of furnace pull) Oil (animal and vegetable) ( 1 ( 1 Oil (mineral) 260.0 130.0 TSS ( 1 ( 1 Fluoride 120.0 60.0 Lead ( 1 ( 1 pH ( 1 ( 1 English units (lb/1,000 lb of furnace pull) Oil (animal and vegetable) ( 1 ( 1 Oil 0.26 0.13 TSS ( 1 ( 1 Fluoride 0.12 0.06 Lead ( 1 ( 1 pH ( 1 ( 1 1 [40 FR 2957, Jan. 16, 1975, as amended at 60 FR 33959, June 29, 1995] § 426.117 Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology. Except as provided in §§ 125.30 through 125.32, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT): The limitations shall be the same as those specified for conventional pollutants (which are defined in § 401.16) in § 426.112 of this subpart for the best practicable control technology currently available (BPT). [51 FR 25000, July 9, 1986] Subpart L—Incandescent Lamp Envelope Manufacturing Subcategory Source: 40 FR 2959, Jan. 16, 1975, unless otherwise noted. § 426.120 Applicability; description of the incandescent lamp envelope manufacturing subcategory. The provisions of this subpart are applicable to discharges resulting from the processes by which (a) raw materials are melted in a furnace and mechanically processed into incandescent lamp envelopes or (b) incandescent lamp envelopes are etched with hydrofluoric acid to produce frosted envelopes. § 426.121 Specialized definitions. For the purpose of this subpart: (a) Except as provided below, the general definitions, abbreviations and methods of analysis set forth in part 401 of this chapter shall apply to this subpart. (b) The term “furnace pull” shall mean that amount of glass drawn from the glass furnace or furnaces. (c) The term “oil” shall mean those components of a waste water amenable to measurement by the technique or techniques described in the most recent addition of “Standard Methods” for the analysis of grease in polluted waters, waste waters, and effluents, such as “Standard Methods,” 13th Edition, 2nd Printing, page 407. (d) The term “product frosted” shall mean that portion of the “furnace pull” associated with the fraction of finished incandescent lamp envelopes which is frosted; this quantity shall be calculated by multiplying “furnace pull” by the fraction of finished incandescent lamp envelopes which is frosted. § 426.122 Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available. Except as provided in §§ 125.30 through 125.32, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available (BPT): (a) Any manufacturing plant which produces incandescent lamp envelopes shall meet the following limitations with regard to the forming operations. Effluent characteristic Effluent limitations Maximum for any 1 day Average of daily values for 30 consecutive days shall not exceed— Metric units (g/kkg of furnace pull) Oil 230.0 115.0 TSS 230.0 115.0 pH ( 1 ( 1 English units (lb/1,000 lb of furnace pull) Oil 0.23 0.115 TSS 0.23 0.115 pH ( 1 ( 1 1 (b) Any manufacturing plant which frosts incandescent lamp envelopes shall meet the following limitations with regard to the finishing operations. Effluent characteristic Effluent limitations Maximum for any 1 day Average of daily values for 30 consecutive days shall not exceed— Metric units (g/kkg of product frosted) Fluoride 230.0 115.0 Ammonia ( 1 ( 1 TSS 460.0 230.0 pH ( 2 ( 2 English units (lb/1000 lb of product frosted) Fluoride 0.23 0.115 Ammonia ( 1 ( 1 TSS 0.46 0.23 pH ( 2 ( 2 1 2 [40 FR 2959, Jan. 16, 1975, as amended at 60 FR 33960, June 29, 1995] § 426.123 Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best available technology economically achievable. Except as provided in §§ 125.30 through 125.32, the following limitations establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a point source subject to the provisions of this subpart after application of the best available technology economically achievable: (a) [Reserved] (b) Any manufacturing plant which frosts incandescent lamp envelopes shall meet the following limitations with regard to the finishing operations. Effluent characteristic Effluent limitations Maximum for any 1 day Average of daily values for 30 consecutive days shall not exceed— Metric units (g/kkg of product frosted) Fluoride 104.0 52.0 Ammonia 240.0 120.0 English units (lb/1,000 lb of product frosted) Fluoride 0.104 0.052 Ammonia 0.24 0.12 [51 FR 25001, July 9, 1986] § 426.124 [Reserved] § 426.125 Standards of performance for new sources. The following standards of performance establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a new source subject to the provisions of this subpart: (a) Any manufacturing plant which produces incandescent lamp envelopes shall meet the following limitations with regard to the forming operations. Effluent characteristic Effluent limitations Maximum for any 1 day Average of daily values for 30 consecutive days shall not exceed— Metric units (g/kkg of furnace pull) Oil 90.0 45.0 TSS 90.0 45.0 pH ( 1 ( 1 English units (lb/1,000 lb of furnace pull) Oil 0.09 0.045 TSS 0.09 0.045 pH ( 1 ( 1 1 (b) Any manufacturing plant which frosts incandescent lamp envelopes shall meet the following limitations with regard to the finishing operations. Effluent characteristic Effluent limitations Maximum for any 1 day Average of daily values for 30 consecutive days shall not exceed— Metric units (g/kkg of product frosted) Fluoride 104.0 52.0 Ammonia 240.0 120.0 TSS 80.0 40.0 pH ( 1 ( 1 English units (lb/1,000 lb of product frosted) Fluoride 0.104 0.052 Ammonia 0.24 0.12 TSS 0.08 0.04 pH ( 1 ( 1 1 § 426.126 Pretreatment standards for new sources. Any new source subject to this subpart that introduces process wastewater pollutants into a publicly owned treatment works must comply with 40 CFR part 403. In addition, the following pretreatment standard establishes the quantity or quality of pollutants or pollutant properties controlled by this section which may be discharged to a publicly owned treatment works by a new point source subject to the provisions of this subpart. Because of the recognition that animal and vegetable oils can be adequately removed in a publicly owned treatment works, whereas mineral oil may not be readily removed and may pass through untreated, two separate limitations are established. Pollutant or pollutant property Pretreatment standards Maximum for any 1 day Average of daily values for 30 consecutive days shall not exceed— Metric units (g/kkg of furnace pull) Oil (animal and vegetable) ( 1 ( 1 Oil (mineral) 230.0 115.0 TSS ( 1 ( 1 pH ( 1 ( 1 English units (lb/1,000 lb of furnace pull) Oil (animal and vegetable) ( 1 ( 1 Oil (mineral) 0.23 0.115 TSS ( 1 ( 1 pH ( 1 ( 1 Metric units (g/kkg of product frosted) Fluoride 104.0 52.0 Ammonia ( 1 ( 1 TSS ( 1 ( 1 pH ( 1 ( 1 English units (lb/1,000 lb of product frosted) Fluoride 0.104 0.052 Ammonia ( 1 ( 1 TSS ( 1 ( 1 pH ( 1 ( 1 1 [40 FR 2959, Jan. 16, 1975, as amended at 60 FR 33960, June 29, 1995] § 426.127 Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology. Except as provided in §§ 125.30 through 125.32, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT): The limitations shall be the same as those specified for conventional pollutants (which are defined in § 401.16) in § 426.122 of this subpart for the best practicable control technology currently available (BPT). [51 FR 25000, July 9, 1986] Subpart M—Hand Pressed and Blown Glass Manufacturing Subcategory Source: 40 FR 2960, Jan. 16, 1975, unless otherwise noted. § 426.130 Applicability; description of the hand pressed and blown glass manufacturing subcategory. The provisions of this subpart are applicable to discharges resulting from the process by which raw materials are melted in a furnace and processed by hand into pressed or blown glassware. This includes those plants which: (a) Produce leaded glass and employ hydrofluoric acid finishing techniques, (b) Produce non-leaded glass and employ hydrofluoric acid finishing techniques, or (c) Produce leaded or non-leaded glass and do not employ hydrofluoric acid finishing techniques. § 426.131 Specialized definitions. For the purpose of this subpart: (a) Except as provided below, the general definitions, abbreviations and methods of analysis set forth in part 401 of this chapter shall apply to this subpart. § 426.132 Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available. Except as provided in §§ 125.30 through 125.32, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available (BPT): (a) Any plant which melts raw materials, produces hand pressed or blown leaded glassware, employs hydrofluoric acid finishing techniques, and discharges greater than 50 gallons per day of process waste water, shall meet the following limitations. Effluent characteristic Effluent limitations Lead No limitation. Fluoride Do. TSS Do. pH Do. (b) Any plant which melts raw materials, produces non-leaded hand pressed or blown glassware, discharges greater than 50 gallons per day of process waste water, and employs hydrofluoric acid finishing techniques shall meet the following limitations. Effluent characteristic Effluent limitations Fluoride No limitation. TSS Do. pH Do. (c) Any plant which melts raw materials, produces leaded or non-leaded hand pressed or blown glassware, discharges greater than 50 gallons per day of process waste water, and does not employ hydrofluoric acid finishing techniques shall meet the following limitations. Effluent characteristic Effluent limitations TSS No limitation. pH Do. [40 FR 2960, Jan. 16, 1975, as amended at 60 FR 33960, June 29, 1995] § 426.133 Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best available technology economically achievable. The following limitations establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a point source subject to the provisions of this subpart after application of the best available technology economically achievable: (a) Any plant which melts raw materials, produces hand pressed or blown leaded glassware, discharges greater than 50 gallons per day of process waste water, and employs hydrofluoric acid finishing techniques shall meet the following limitations. Effluent characteristic Effluent limitations (mg/l) Maximum for any 1 day Average of daily values for 30 consecutive days shall not exceed— Lead 0.2 0.1 Fluoride 26.0 13.0 (b) Any plant which melts raw materials, produces non-leaded hand pressed or blown glassware, discharges greater than 50 gallons per day of process waste water, and employs hydrofluoric acid finishing techniques shall meet the following limitations. Effluent characteristic Effluent limitations (mg/l) Maximum for any 1 day Average of daily values for 30 consecutive days shall not exceed— Fluoride 26.0 13.0 [44 FR 50747, Aug. 29, 1979, as amended at 51 FR 25001, July 9, 1986] § 426.134 [Reserved] § 426.135 Standards of performance for new sources. The following standards of performance establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a new source subject to the provisions of this subpart: (a) Any plant which melts raw materials, produces hand pressed or blown leaded glassware, discharges greater than 50 gallons per day of process waste water, and employs hydrofluoric acid finishing techniques shall meet the following limitations. Effluent characteristic Effluent limitations (mg/l) Maximum for any 1 day Average of daily values for 30 consecutive days shall not exceed— Lead 0.2 0.1 Fluoride 26.0 13.0 TSS 20.0 10.0 pH ( 1 ( 1 1 (b) Any plant which melts raw materials, produces non-leaded hand pressed or blown glassware, discharges greater than 50 gallons per day of process waste water, and employs hydrofluoric acid finishing techniques shall meet the following limitations. Effluent characteristic Effluent limitations (mg/l) Maximum for any 1 day Average of daily values for 30 consecutive days shall not exceed— Fluoride 26.0 13.0 TSS 20.0 10.0 pH ( 1 ( 1 1 (c) Any plant which melts raw materials, produces leaded or non-leaded hand pressed or blown glassware, discharges greater than 50 gallons per day of process waste water, and does not employ hydrofluoric acid finishing techniques shall meet the following limitations. Effluent characteristic Effluent limitations (mg/l) Maximum for any 1 day Average of daily values for 30 consecutive days shall not exceed— TSS 20.0 10.0 pH ( 1 ( 1 1 § 426.136 Pretreatment standards for new sources. Any new source subject to this subpart that introduces process wastewater pollutants into a publicly owned treatment works must comply with 40 CFR part 403. In addition, the following pretreatment standard establishes the quantity or quality of pollutants or pollutant properties controlled by this section which may be discharged to a publicly owned treatment works by a new point source subject to the provisions of this subpart. Pollutant or pollutant property Pretreatment standards (mg/l) Maximum for any 1 day Average of daily values for 30 consecutive days shall not exceed— (a): Fluoride 26.0 13.0 Lead ( 1 ( 1 TSS ( 1 ( 1 pH ( 1 ( 1 (b): Fluoride 26.0 13.0 Lead ( 1 ( 1 TSS ( 1 ( 1 pH ( 1 ( 1 (c): TSS ( 1 ( 1 pH ( 1 ( 1 1 [40 FR 2960, Jan. 16, 1975, as amended at 60 FR 33960, June 29, 1995] § 426.137 [Reserved]

Related documents

Record · ID 509584 · SHA-256 c65cb4a406a09507
Retrieved via Conceptio — every document is proof-bundled with source, license, and retrieval metadata.