ConceptioArchiveEU TED (Tenders Electronic Daily)
EU TED (Tenders Electronic Daily)open access

North Macedonia – Angiography supplies – Procurement of medical dispensable material for Interventional Cardiology – coronary stents. — Public Health Institution Specialized Hospital for prevention, treatment and rehabilitation of cardiovas

Public Health Institution Specialized Hospital for prevention, treatment and rehabilitation of cardiovascular diseases – Ohrid · EU Tenders Electronic Daily (TED)
EU TED (Tenders Electronic Daily) · Contracts · License: Open Access
Open Source ↗
mkd
european union, public procurement, eu tender, ted, tenders electronic daily, 605445-2026, Public Health Institution Specialized Hospital for prevention, treatment and rehabilitation of cardiovascular diseases – Ohrid, MKD, supplies, cn-standard, 33111710, MKD

16 https://www.cardioohrid.mk/ https://e-nabavki.gov.mk ORG-0001 Public Health Institution Specialized Hospital for prevention, treatment and rehabilitation of cardiovascular diseases – Ohrid Settlement “St. Stefan” b.b. – Ohrid Ohrid MK003 MKD 4087445 https://e-nabavki.gov.mk +38946277201 [email protected] https://op.europa.eu ORG-0000 Publications Office of the European Union Luxembourg 2417 LU000 LUX PUBL +352 29291 [email protected] 00605445-2026 169/2026 2026-09-02+02:00 2.3 eforms-sdk-1.14 915f6802-17e8-4510-80aa-ea2c0d0ddc12 0d6edea8-112d-4b24-8119-493420d17c69 2026-09-01Z 07:14:08Z 01 32014L0024 cn-standard ENG https://e-nabavki.gov.mk pub-undert health ORG-0001 ted-esen ORG-0000 ted-esen ORG-0001 epo-procurement-document 11 open false 02-667 Procurement of medical dispensable material for Interventional Cardiology – coronary stents. The subject of the agreement consists of 11 separate parts, including: supplies 479674 33111710 Settlement “St. Stefan” b.b. – Ohrid Ohrid MK003 MKD LOT-0001 not-allowed no-eu-funds not-allowed true Guarantee for quality fulfillment of the agreement - The contracting authority shall ask from the seller whose offer is chosen as the most favourable to provide a bank guarantee for quality and promptly fulfillment of the agreement in the amount of 10% of the agreement value with VAT. The sellers are obliged to also submit a Statement for providing a guarantee for quality and promptly fulfillment of the agreement. MKD 02-667 non-restricted-document https://e-nabavki.gov.mk late-none epo-procurement-document none no allowed not-allowed true price - price ...........................................60 points quality - quality........................................ 40 points. The element quality is determined by a number of multicentric randomized studies related to the offered stent, published in a magazine that during the year in which it was published, has been reviewed in the Current Content referential database with a single impact factor (IF) of 5 or bigger than 5, with positive results sufficient for performing clinically relevant conclusions and their application in the broad clinical practice. The publication results have to be about the offered stent or for the previous generation of that stent. In case the publication results are about the previous generation of the stent, the bidder is obliged to submit a statement verified by the manufacturer that the offered stent is an improved version of the same stent. If the studies are about a different material of the stent, if a different medicine is used with the stent, if a different kind of a polymer is used on the stent, or if there are any kinds of changes to the stent design and platform, the studies shall not be accepted. For evaluating the element quality, every single multicentric randomized study shall receive 8 points. If the total number of points calculated for the studies is more than 40, the total number of points for the element quality shall be 40, as the maximum number of points. For proving the requirements for the element quality, the economic operators shall also submit: - printed materials from the magazine in which the randomized studies are published or to provide the internet link through which the authenticity of the submitted document can be checked. ORG-0001 ORG-0001 https://e-nabavki.gov.mk ORG-0001 ORG-0001 90 ORG-0001 ORG-0001 MKD true true required true 2026-09-30+02:00 12:00:00+02:00 2026-09-24+02:00 12:00:00+02:00 2026-09-30+02:00 12:00:00+02:00 https://e-nabavki.gov.mk false none none 02-667/01 A coronary stent made of a chromium alloy (cobalt or platinum) with a continuous sinusoidal configuration and a permanent polymer, coated with an immunosuppressant that stops the cell cycle progression by inhibiting the m-TOR A coronary stent made of a chromium alloy (cobalt or platinum) with a continuous sinusoidal configuration and a permanent polymer, coated with an immunosuppressant that stops the cell cycle progression by inhibiting the m-TOR supplies 140 In order to qualify, the economic operator shall confirm the required technical and professional competence for fulfilling the subject agreement for public procurement via the following minimal conditions: - offering medical devices and materials that are in accordance with the requirements in the technical specifications. The economic operator proves the fulfillment of the minimal conditions by submitting: - catalogues for each part of the subject of procurement must be submitted along with the offer. These catalogues shall contain a detailed description of the characteristics of the offered goods in either Macedonian or English, and those characteristics shall be clearly marked in accordance with the requirements in the technical specifications (a scanned catalogue attached on ESPP). 49430 33111710 Ohrid MK003 MKD 12 LOT-0002 not-allowed no-eu-funds not-allowed true Guarantee for quality fulfillment of the agreement - The contracting authority shall ask from the seller whose offer is chosen as the most favourable to provide a bank guarantee for quality and promptly fulfillment of the agreement in the amount of 10% of the agreement value with VAT. The sellers are obliged to also submit a Statement for providing a guarantee for quality and promptly fulfillment of the agreement. MKD 02-667 non-restricted-document https://e-nabavki.gov.mk late-none epo-procurement-document none no allowed not-allowed true price - price ...........................................60 points quality - quality........................................ 40 points. The element quality is determined by a number of multicentric randomized studies related to the offered stent, published in a magazine that during the year in which it was published, has been reviewed in the Current Content referential database with a single impact factor (IF) of 5 or bigger than 5, with positive results sufficient for performing clinically relevant conclusions and their application in the broad clinical practice. The publication results have to be about the offered stent or for the previous generation of that stent. In case the publication results are about the previous generation of the stent, the bidder is obliged to submit a statement verified by the manufacturer that the offered stent is an improved version of the same stent. If the studies are about a different material of the stent, if a different medicine is used with the stent, if a different kind of a polymer is used on the stent, or if there are any kinds of changes to the stent design and platform, the studies shall not be accepted. For evaluating the element quality, every single multicentric randomized study shall receive 8 points. If the total number of points calculated for the studies is more than 40, the total number of points for the element quality shall be 40, as the maximum number of points. For proving the requirements for the element quality, the economic operators shall also submit: - printed materials from the magazine in which the randomized studies are published or to provide the internet link through which the authenticity of the submitted document can be checked. ORG-0001 ORG-0001 https://e-nabavki.gov.mk ORG-0001 ORG-0001 90 ORG-0001 ORG-0001 MKD true true required true 2026-09-30+02:00 12:00:00+02:00 2026-09-24+02:00 12:00:00+02:00 2026-09-30+02:00 12:00:00+02:00 https://e-nabavki.gov.mk false none none 02-667/02 A coronary stent made of a chromium alloy (cobalt or platinum) with a bioabsorbable polymer and hybrid coating with an active component of an immunosuppressant that stops the cell cycle progression by inhibiting the m-TOR and a passive component that lowers the thrombogenicity A coronary stent made of a chromium alloy (cobalt or platinum) with a bioabsorbable polymer and hybrid coating with an active component of an immunosuppressant that stops the cell cycle progression by inhibiting the m-TOR and a passive component that lowers the thrombogenicity supplies 70 In order to qualify, the economic operator shall confirm the required technical and professional competence for fulfilling the subject agreement for public procurement via the following minimal conditions: - offering medical devices and materials that are in accordance with the requirements in the technical specifications. The economic operator proves the fulfillment of the minimal conditions by submitting: - catalogues for each part of the subject of procurement must be submitted along with the offer. These catalogues shall contain a detailed description of the characteristics of the offered goods in either Macedonian or English, and those characteristics shall be clearly marked in accordance with the requirements in the technical specifications (a scanned catalogue attached on ESPP). 25609 33111710 Ohrid MK003 MKD 12 LOT-0003 not-allowed no-eu-funds not-allowed true Guarantee for quality fulfillment of the agreement - The contracting authority shall ask from the seller whose offer is chosen as the most favourable to provide a bank guarantee for quality and promptly fulfillment of the agreement in the amount of 10% of the agreement value with VAT. The sellers are obliged to also submit a Statement for providing a guarantee for quality and promptly fulfillment of the agreement. MKD 02-667 non-restricted-document https://e-nabavki.gov.mk late-none epo-procurement-document none no allowed not-allowed true price - price ...........................................60 points quality - quality........................................ 40 points. The element quality is determined by a number of multicentric randomized studies related to the offered stent, published in a magazine that during the year in which it was published, has been reviewed in the Current Content referential database with a single impact factor (IF) of 5 or bigger than 5, with positive results sufficient for performing clinically relevant conclusions and their application in the broad clinical practice. The publication results have to be about the offered stent or for the previous generation of that stent. In case the publication results are about the previous generation of the stent, the bidder is obliged to submit a statement verified by the manufacturer that the offered stent is an improved version of the same stent. If the studies are about a different material of the stent, if a different medicine is used with the stent, if a different kind of a polymer is used on the stent, or if there are any kinds of changes to the stent design and platform, the studies shall not be accepted. For evaluating the element quality, every single multicentric randomized study shall receive 8 points. If the total number of points calculated for the studies is more than 40, the total number of points for the element quality shall be 40, as the maximum number of points. For proving the requirements for the element quality, the economic operators shall also submit: - printed materials from the magazine in which the randomized studies are published or to provide the internet link through which the authenticity of the submitted document can be checked. ORG-0001 ORG-0001 https://e-nabavki.gov.mk ORG-0001 ORG-0001 90 ORG-0001 ORG-0001 MKD true true required true 2026-09-30+02:00 12:00:00+02:00 2026-09-24+02:00 12:00:00+02:00 2026-09-30+02:00 12:00:00+02:00 https://e-nabavki.gov.mk false none none 02-667/03 A coronary stent made of a chromium and cobalt alloy with an abluminal biodegradable polymer, coated with an immunosuppressant that stops the cell cycle progression by inhibiting the m-TOR. Diameter 2.0-4.5mm, length 9-50mm. A coronary stent made of a chromium and cobalt alloy with an abluminal biodegradable polymer, coated with an immunosuppressant that stops the cell cycle progression by inhibiting the m-TOR. Diameter 2.0-4.5mm, length 9-50mm. supplies 280 In order to qualify, the economic operator shall confirm the required technical and professional competence for fulfilling the subject agreement for public procurement via the following minimal conditions: - offering medical devices and materials that are in accordance with the requirements in the technical specifications. The economic operator proves the fulfillment of the minimal conditions by submitting: - catalogues for each part of the subject of procurement must be submitted along with the offer. These catalogues shall contain a detailed description of the characteristics of the offered goods in either Macedonian or English, and those characteristics shall be clearly marked in accordance with the requirements in the technical specifications (a scanned catalogue attached on ESPP). 106991 33111710 Ohrid MK003 MKD 12 LOT-0004 not-allowed no-eu-funds not-allowed true Guarantee for quality fulfillment of the agreement - The contracting authority shall ask from the seller whose offer is chosen as the most favourable to provide a bank guarantee for quality and promptly fulfillment of the agreement in the amount of 10% of the agreement value with VAT. The sellers are obliged to also submit a Statement for providing a guarantee for quality and promptly fulfillment of the agreement. MKD 02-667 non-restricted-document https://e-nabavki.gov.mk late-none epo-procurement-document none no allowed not-allowed true price - price ...........................................60 points quality - quality........................................ 40 points. The element quality is determined by a number of multicentric randomized studies related to the offered stent, published in a magazine that during the year in which it was published, has been reviewed in the Current Content referential database with a single impact factor (IF) of 5 or bigger than 5, with positive results sufficient for performing clinically relevant conclusions and their application in the broad clinical practice. The publication results have to be about the offered stent or for the previous generation of that stent. In case the publication results are about the previous generation of the stent, the bidder is obliged to submit a statement verified by the manufacturer that the offered stent is an improved version of the same stent. If the studies are about a different material of the stent, if a different medicine is used with the stent, if a different kind of a polymer is used on the stent, or if there are any kinds of changes to the stent design and platform, the studies shall not be accepted. For evaluating the element quality, every single multicentric randomized study shall receive 8 points. If the total number of points calculated for the studies is more than 40, the total number of points for the element quality shall be 40, as the maximum number of points. For proving the requirements for the element quality, the economic operators shall also submit: - printed materials from the magazine in which the randomized studies are published or to provide the internet link through which the authenticity of the submitted document can be checked. ORG-0001 ORG-0001 https://e-nabavki.gov.mk ORG-0001 ORG-0001 90 ORG-0001 ORG-0001 MKD true true required true 2026-09-30+02:00 12:00:00+02:00 2026-09-24+02:00 12:00:00+02:00 2026-09-30+02:00 12:00:00+02:00 https://e-nabavki.gov.mk false none none 02-667/04 A coronary stent made of a chromium and cobalt alloy with a hybrid cell design and a low stent crossing profile ≤ 0.041” (it refers to a stent with a diameter of up to 3mm), with a permanent polymer, coated with an immunosuppressant that stops the cell cycle progression by inhibiting the m-TOR A coronary stent made of a chromium and cobalt alloy with a hybrid cell design and a low stent crossing profile ≤ 0.041” (it refers to a stent with a diameter of up to 3mm), with a permanent polymer, coated with an immunosuppressant that stops the cell cycle progression by inhibiting the m-TOR supplies 210 In order to qualify, the economic operator shall confirm the required technical and professional competence for fulfilling the subject agreement for public procurement via the following minimal conditions: - offering medical devices and materials that are in accordance with the requirements in the technical specifications. The economic operator proves the fulfillment of the minimal conditions by submitting: - catalogues for each part of the subject of procurement must be submitted along with the offer. These catalogues shall contain a detailed description of the characteristics of the offered goods in either Macedonian or English, and those characteristics shall be clearly marked in accordance with the requirements in the technical specifications (a scanned catalogue attached on ESPP). 99186 33111710 Ohrid MK003 MKD 12 LOT-0005 not-allowed no-eu-funds not-allowed true Guarantee for quality fulfillment of the agreement - The contracting authority shall ask from the seller whose offer is chosen as the most favourable to provide a bank guarantee for quality and promptly fulfillment of the agreement in the amount of 10% of the agreement value with VAT. The sellers are obliged to also submit a Statement for providing a guarantee for quality and promptly fulfillment of the agreement. MKD 02-667 non-restricted-document https://e-nabavki.gov.mk late-none epo-procurement-document none no allowed not-allowed true price - price ...........................................60 points quality - quality........................................ 40 points. The element quality is determined by a number of multicentric randomized studies related to the offered stent, published in a magazine that during the year in which it was published, has been reviewed in the Current Content referential database with a single impact factor (IF) of 5 or bigger than 5, with positive results sufficient for performing clinically relevant conclusions and their application in the broad clinical practice. The publication results have to be about the offered stent or for the previous generation of that stent. In case the publication results are about the previous generation of the stent, the bidder is obliged to submit a statement verified by the manufacturer that the offered stent is an improved version of the same stent. If the studies are about a different material of the stent, if a different medicine is used with the stent, if a different kind of a polymer is used on the stent, or if there are any kinds of changes to the stent design and platform, the studies shall not be accepted. For evaluating the element quality, every single multicentric randomized study shall receive 8 points. If the total number of points calculated for the studies is more than 40, the total number of points for the element quality shall be 40, as the maximum number of points. For proving the requirements for the element quality, the economic operators shall also submit: - printed materials from the magazine in which the randomized studies are published or to provide the internet link through which the authenticity of the submitted document can be checked. ORG-0001 ORG-0001 https://e-nabavki.gov.mk ORG-0001 ORG-0001 90 ORG-0001 ORG-0001 MKD true true required true 2026-09-30+02:00 12:00:00+02:00 2026-09-24+02:00 12:00:00+02:00 2026-09-30+02:00 12:00:00+02:00 https://e-nabavki.gov.mk false none none 02-667/05 A coronary stent made of multiple cobalt alloys (chromium or nickel) designed for large post-dilatation expansions ≥ 5.5mm in large blood vessels, with a permanent polymer, coated with an immunosuppressant that stops the cell cycle progression by inhibiting the m-TOR A coronary stent made of multiple cobalt alloys (chromium or nickel) designed for large post-dilatation expansions ≥ 5.5mm in large blood vessels, with a permanent polymer, coated with an immunosuppressant that stops the cell cycle progression by inhibiting the m-TOR supplies 120 In order to qualify, the economic operator shall confirm the required technical and professional competence for fulfilling the subject agreement for public procurement via the following minimal conditions: - offering medical devices and materials that are in accordance with the requirements in the technical specifications. The economic operator proves the fulfillment of the minimal conditions by submitting: - catalogues for each part of the subject of procurement must be submitted along with the offer. These catalogues shall contain a detailed description of the characteristics of the offered goods in either Macedonian or English, and those characteristics shall be clearly marked in accordance with the requirements in the technical specifications (a scanned catalogue attached on ESPP). 57560 33111710 Ohrid MK003 MKD 12 LOT-0006 not-allowed no-eu-funds not-allowed true Guarantee for quality fulfillment of the agreement - The contracting authority shall ask from the seller whose offer is chosen as the most favourable to provide a bank guarantee for quality and promptly fulfillment of the agreement in the amount of 10% of the agreement value with VAT. The sellers are obliged to also submit a Statement for providing a guarantee for quality and promptly fulfillment of the agreement. MKD 02-667 non-restricted-document https://e-nabavki.gov.mk late-none epo-procurement-document none no allowed not-allowed true price - price ...........................................60 points quality - quality........................................ 40 points. The element quality is determined by a number of multicentric randomized studies related to the offered stent, published in a magazine that during the year in which it was published, has been reviewed in the Current Content referential database with a single impact factor (IF) of 5 or bigger than 5, with positive results sufficient for performing clinically relevant conclusions and their application in the broad clinical practice. The publication results have to be about the offered stent or for the previous generation of that stent. In case the publication results are about the previous generation of the stent, the bidder is obliged to submit a statement verified by the manufacturer that the offered stent is an improved version of the same stent. If the studies are about a different material of the stent, if a different medicine is used with the stent, if a different kind of a polymer is used on the stent, or if there are any kinds of changes to the stent design and platform, the studies shall not be accepted. For evaluating the element quality, every single multicentric randomized study shall receive 8 points. If the total number of points calculated for the studies is more than 40, the total number of points for the element quality shall be 40, as the maximum number of points. For proving the requirements for the element quality, the economic operators shall also submit: - printed materials from the magazine in which the randomized studies are published or to provide the internet link through which the authenticity of the submitted document can be checked. ORG-0001 ORG-0001 https://e-nabavki.gov.mk ORG-0001 ORG-0001 90 ORG-0001 ORG-0001 MKD true true required true 2026-09-30+02:00 12:00:00+02:00 2026-09-24+02:00 12:00:00+02:00 2026-09-30+02:00 12:00:00+02:00 https://e-nabavki.gov.mk false none none 02-667/06 A coronary stent made of a chromium and platinum alloy with a permanent polymer, coated with an immunosuppressant that stops the cell cycle progression by inhibiting the m-TOR A coronary stent made of a chromium and platinum alloy with a permanent polymer, coated with an immunosuppressant that stops the cell cycle progression by inhibiting the m-TOR supplies 70 In order to qualify, the economic operator shall confirm the required technical and professional competence for fulfilling the subject agreement for public procurement via the following minimal conditions: - offering medical devices and materials that are in accordance with the requirements in the technical specifications. The economic operator proves the fulfillment of the minimal conditions by submitting: - catalogues for each part of the subject of procurement must be submitted along with the offer. These catalogues shall contain a detailed description of the characteristics of the offered goods in either Macedonian or English, and those characteristics shall be clearly marked in accordance with the requirements in the technical specifications (a scanned catalogue attached on ESPP). 20487 33111710 Ohrid MK003 MKD 12 LOT-0007 not-allowed no-eu-funds not-allowed true Guarantee for quality fulfillment of the agreement - The contracting authority shall ask from the seller whose offer is chosen as the most favourable to provide a bank guarantee for quality and promptly fulfillment of the agreement in the amount of 10% of the agreement value with VAT. The sellers are obliged to also submit a Statement for providing a guarantee for quality and promptly fulfillment of the agreement. MKD 02-667 non-restricted-document https://e-nabavki.gov.mk late-none epo-procurement-document none no allowed not-allowed true price - price ...........................................60 points quality - quality........................................ 40 points. The element quality is determined by a number of multicentric randomized studies related to the offered stent, published in a magazine that during the year in which it was published, has been reviewed in the Current Content referential database with a single impact factor (IF) of 5 or bigger than 5, with positive results sufficient for performing clinically relevant conclusions and their application in the broad clinical practice. The publication results have to be about the offered stent or for the previous generation of that stent. In case the publication results are about the previous generation of the stent, the bidder is obliged to submit a statement verified by the manufacturer that the offered stent is an improved version of the same stent. If the studies are about a different material of the stent, if a different medicine is used with the stent, if a different kind of a polymer is used on the stent, or if there are any kinds of changes to the stent design and platform, the studies shall not be accepted. For evaluating the element quality, every single multicentric randomized study shall receive 8 points. If the total number of points calculated for the studies is more than 40, the total number of points for the element quality shall be 40, as the maximum number of points. For proving the requirements for the element quality, the economic operators shall also submit: - printed materials from the magazine in which the randomized studies are published or to provide the internet link through which the authenticity of the submitted document can be checked. ORG-0001 ORG-0001 https://e-nabavki.gov.mk ORG-0001 ORG-0001 90 ORG-0001 ORG-0001 MKD true true required true 2026-09-30+02:00 12:00:00+02:00 2026-09-24+02:00 12:00:00+02:00 2026-09-30+02:00 12:00:00+02:00 https://e-nabavki.gov.mk false none none 02-667/07 A coronary stent made of a chromium and platinum alloy with an abluminal biodegradable polymer, coated with an immunosuppressant that stops the cell cycle progression by inhibiting the m-TOR, with a diameter from 2.25 to 5mm, length from 8 to 48mm, compatible with 5F guiding catheter for all dimensions A coronary stent made of a chromium and platinum alloy with an abluminal biodegradable polymer, coated with an immunosuppressant that stops the cell cycle progression by inhibiting the m-TOR, with a diameter from 2.25 to 5mm, length from 8 to 48mm, compatible with 5F guiding catheter for all dimensions supplies 30 In order to qualify, the economic operator shall confirm the required technical and professional competence for fulfilling the subject agreement for public procurement via the following minimal conditions: - offering medical devices and materials that are in accordance with the requirements in the technical specifications. The economic operator proves the fulfillment of the minimal conditions by submitting: - catalogues for each part of the subject of procurement must be submitted along with the offer. These catalogues shall contain a detailed description of the characteristics of the offered goods in either Macedonian or English, and those characteristics shall be clearly marked in accordance with the requirements in the technical specifications (a scanned catalogue attached on ESPP). 12439 33111710 Ohrid MK003 MKD 12 LOT-0008 not-allowed no-eu-funds not-allowed true Guarantee for quality fulfillment of the agreement - The contracting authority shall ask from the seller whose offer is chosen as the most favourable to provide a bank guarantee for quality and promptly fulfillment of the agreement in the amount of 10% of the agreement value with VAT. The sellers are obliged to also submit a Statement for providing a guarantee for quality and promptly fulfillment of the agreement. MKD 02-667 non-restricted-document https://e-nabavki.gov.mk late-none epo-procurement-document none no allowed not-allowed true price - price ...........................................60 points quality - quality........................................ 40 points. The element quality is determined by a number of multicentric randomized studies related to the offered stent, published in a magazine that during the year in which it was published, has been reviewed in the Current Content referential database with a single impact factor (IF) of 5 or bigger than 5, with positive results sufficient for performing clinically relevant conclusions and their application in the broad clinical practice. The publication results have to be about the offered stent or for the previous generation of that stent. In case the publication results are about the previous generation of the stent, the bidder is obliged to submit a statement verified by the manufacturer that the offered stent is an improved version of the same stent. If the studies are about a different material of the stent, if a different medicine is used with the stent, if a different kind of a polymer is used on the stent, or if there are any kinds of changes to the stent design and platform, the studies shall not be accepted. For evaluating the element quality, every single multicentric randomized study shall receive 8 points. If the total number of points calculated for the studies is more than 40, the total number of points for the element quality shall be 40, as the maximum number of points. For proving the requirements for the element quality, the economic operators shall also submit: - printed materials from the magazine in which the randomized studies are published or to provide the internet link through which the authenticity of the submitted document can be checked. ORG-0001 ORG-0001 https://e-nabavki.gov.mk ORG-0001 ORG-0001 90 ORG-0001 ORG-0001 MKD true true required true 2026-09-30+02:00 12:00:00+02:00 2026-09-24+02:00 12:00:00+02:00 2026-09-30+02:00 12:00:00+02:00 https://e-nabavki.gov.mk false none none 02-667/08 A coronary stent made of a chromium and cobalt alloy, with a polymer and carrier free technology, coated with an immunosuppressant on the abluminal surface that stops the cell cycle progression by inhibiting the m-TOR. - time of delivery of the medicine shall be 30 days or less, - effective length of the shaft 142cm+/3cm, - shaft diameter: proximal 2.1F or less, distal 2.6F or less - struts thickn A coronary stent made of a chromium and cobalt alloy, with a polymer and carrier free technology, coated with an immunosuppressant on the abluminal surface that stops the cell cycle progression by inhibiting the m-TOR. - time of delivery of the medicine shall be 30 days or less, - effective length of the shaft 142cm+/3cm, - shaft diameter: proximal 2.1F or less, distal 2.6F or less - struts thickness: 85 micrometers or less, for a stent with a diameter of up to 3.0mm, - stent length: 9-36mm or longer, - stent diameter: 2.25-4.0mm or more, - maximum expansion of the stent diameter 5.95mm for stents with a diameter of 3.5mm and 4mm. supplies 30 In order to qualify, the economic operator shall confirm the required technical and professional competence for fulfilling the subject agreement for public procurement via the following minimal conditions: - offering medical devices and materials that are in accordance with the requirements in the technical specifications. The economic operator proves the fulfillment of the minimal conditions by submitting: - catalogues for each part of the subject of procurement must be submitted along with the offer. These catalogues shall contain a detailed description of the characteristics of the offered goods in either Macedonian or English, and those characteristics shall be clearly marked in accordance with the requirements in the technical specifications (a scanned catalogue attached on ESPP). 14146 33111710 Ohrid MK003 MKD 12 LOT-0009 not-allowed no-eu-funds not-allowed true Guarantee for quality fulfillment of the agreement - The contracting authority shall ask from the seller whose offer is chosen as the most favourable to provide a bank guarantee for quality and promptly fulfillment of the agreement in the amount of 10% of the agreement value with VAT. The sellers are obliged to also submit a Statement for providing a guarantee for quality and promptly fulfillment of the agreement. MKD 02-667 non-restricted-document https://e-nabavki.gov.mk late-none epo-procurement-document none no allowed not-allowed true price - price ...........................................60 points quality - quality........................................ 40 points. The element quality is determined by a number of multicentric randomized studies related to the offered stent, published in a magazine that during the year in which it was published, has been reviewed in the Current Content referential database with a single impact factor (IF) of 5 or bigger than 5, with positive results sufficient for performing clinically relevant conclusions and their application in the broad clinical practice. The publication results have to be about the offered stent or for the previous generation of that stent. In case the publication results are about the previous generation of the stent, the bidder is obliged to submit a statement verified by the manufacturer that the offered stent is an improved version of the same stent. If the studies are about a different material of the stent, if a different medicine is used with the stent, if a different kind of a polymer is used on the stent, or if there are any kinds of changes to the stent design and platform, the studies shall not be accepted. For evaluating the element quality, every single multicentric randomized study shall receive 8 points. If the total number of points calculated for the studies is more than 40, the total number of points for the element quality shall be 40, as the maximum number of points. For proving the requirements for the element quality, the economic operators shall also submit: - printed materials from the magazine in which the randomized studies are published or to provide the internet link through which the authenticity of the submitted document can be checked. ORG-0001 ORG-0001 https://e-nabavki.gov.mk ORG-0001 ORG-0001 90 ORG-0001 ORG-0001 MKD true true required true 2026-09-30+02:00 12:00:00+02:00 2026-09-24+02:00 12:00:00+02:00 2026-09-30+02:00 12:00:00+02:00 https://e-nabavki.gov.mk false none none 02-667/09 A coronary stent made of a chromium and cobalt alloy, with a biodegradable polymer (PLA) technology, coated with an immunosuppressant on the abluminal surface that stops the cell cycle progression by inhibiting the m-TOR. - time of delivery of the medicine and polymer absorption shall be synchronized, for 9 months or less, -Lesion entry profile: 0.017“ or less, - effective length of the shaft 142 A coronary stent made of a chromium and cobalt alloy, with a biodegradable polymer (PLA) technology, coated with an immunosuppressant on the abluminal surface that stops the cell cycle progression by inhibiting the m-TOR. - time of delivery of the medicine and polymer absorption shall be synchronized, for 9 months or less, -Lesion entry profile: 0.017“ or less, - effective length of the shaft 142cm+/-3cm, - shaft diameter: proximal 2.0F or less, distal 2.6F or less - struts thickness: 85 micrometers or less, for a stent with a diameter of up to 3.0mm, - stent length: 9-36mm or longer, - stent diameter: 2.25-4.0mm or more, -maximum expansion of the stent diameter 5.95mm for stents with a diameter of 3.5mm and 4mm. supplies 100 In order to qualify, the economic operator shall confirm the required technical and professional competence for fulfilling the subject agreement for public procurement via the following minimal conditions: - offering medical devices and materials that are in accordance with the requirements in the technical specifications. The economic operator proves the fulfillment of the minimal conditions by submitting: - catalogues for each part of the subject of procurement must be submitted along with the offer. These catalogues shall contain a detailed description of the characteristics of the offered goods in either Macedonian or English, and those characteristics shall be clearly marked in accordance with the requirements in the technical specifications (a scanned catalogue attached on ESPP). 32520 33111710 Ohrid MK003 MKD 12 LOT-0010 not-allowed no-eu-funds not-allowed true Guarantee for quality fulfillment of the agreement - The contracting authority shall ask from the seller whose offer is chosen as the most favourable to provide a bank guarantee for quality and promptly fulfillment of the agreement in the amount of 10% of the agreement value with VAT. The sellers are obliged to also submit a Statement for providing a guarantee for quality and promptly fulfillment of the agreement. MKD 02-667 non-restricted-document https://e-nabavki.gov.mk late-none epo-procurement-document none no allowed not-allowed true price - price ...........................................60 points quality - quality........................................ 40 points. The element quality is determined by a number of multicentric randomized studies related to the offered stent, published in a magazine that during the year in which it was published, has been reviewed in the Current Content referential database with a single impact factor (IF) of 5 or bigger than 5, with positive results sufficient for performing clinically relevant conclusions and their application in the broad clinical practice. The publication results have to be about the offered stent or for the previous generation of that stent. In case the publication results are about the previous generation of the stent, the bidder is obliged to submit a statement verified by the manufacturer that the offered stent is an improved version of the same stent. If the studies are about a different material of the stent, if a different medicine is used with the stent, if a different kind of a polymer is used on the stent, or if there are any kinds of changes to the stent design and platform, the studies shall not be accepted. For evaluating the element quality, every single multicentric randomized study shall receive 8 points. If the total number of points calculated for the studies is more than 40, the total number of points for the element quality shall be 40, as the maximum number of points. For proving the requirements for the element quality, the economic operators shall also submit: - printed materials from the magazine in which the randomized studies are published or to provide the internet link through which the authenticity of the submitted document can be checked. ORG-0001 ORG-0001 https://e-nabavki.gov.mk ORG-0001 ORG-0001 90 ORG-0001 ORG-0001 MKD true true required true 2026-09-30+02:00 12:00:00+02:00 2026-09-24+02:00 12:00:00+02:00 2026-09-30+02:00 12:00:00+02:00 https://e-nabavki.gov.mk false none none 02-667/10 A coronary stent made of cobalt-chromium alloy, multi-link, featuring a Peak-to-Valley stent design for treatment of tapered (conically narrowed) coronary lesions with small and large diameters, coated with a permanent polymer and the cytostatic everolimus (DES). Strut thickness: 81 micrometers. Diameter range: 2 to 5 mm, length from 8 to 48 mm, and expandable up to 5.75 mm for diameters of 3.5 to A coronary stent made of cobalt-chromium alloy, multi-link, featuring a Peak-to-Valley stent design for treatment of tapered (conically narrowed) coronary lesions with small and large diameters, coated with a permanent polymer and the cytostatic everolimus (DES). Strut thickness: 81 micrometers. Diameter range: 2 to 5 mm, length from 8 to 48 mm, and expandable up to 5.75 mm for diameters of 3.5 to 5.0 mm, and up to 3.75 mm for diameters of 2.0 to 3.25 mm, without shortening supplies 30 In order to qualify, the economic operator shall confirm the required technical and professional competence for fulfilling the subject agreement for public procurement via the following minimal conditions: - offering medical devices and materials that are in accordance with the requirements in the technical specifications. The economic operator proves the fulfillment of the minimal conditions by submitting: - catalogues for each part of the subject of procurement must be submitted along with the offer. These catalogues shall contain a detailed description of the characteristics of the offered goods in either Macedonian or English, and those characteristics shall be clearly marked in accordance with the requirements in the technical specifications (a scanned catalogue attached on ESPP). 14878 33111710 Ohrid MK003 MKD 12 LOT-0011 not-allowed no-eu-funds not-allowed true Guarantee for quality fulfillment of the agreement - The contracting authority shall ask from the seller whose offer is chosen as the most favourable to provide a bank guarantee for quality and promptly fulfillment of the agreement in the amount of 10% of the agreement value with VAT. The sellers are obliged to also submit a Statement for providing a guarantee for quality and promptly fulfillment of the agreement. MKD 02-667 non-restricted-document https://e-nabavki.gov.mk late-none epo-procurement-document none no allowed not-allowed true price - price ...........................................60 points quality - quality........................................ 40 points. The element quality is determined by a number of multicentric randomized studies related to the offered stent, published in a magazine that during the year in which it was published, has been reviewed in the Current Content referential database with a single impact factor (IF) of 5 or bigger than 5, with positive results sufficient for performing clinically relevant conclusions and their application in the broad clinical practice. The publication results have to be about the offered stent or for the previous generation of that stent. In case the publication results are about the previous generation of the stent, the bidder is obliged to submit a statement verified by the manufacturer that the offered stent is an improved version of the same stent. If the studies are about a different material of the stent, if a different medicine is used with the stent, if a different kind of a polymer is used on the stent, or if there are any kinds of changes to the stent design and platform, the studies shall not be accepted. For evaluating the element quality, every single multicentric randomized study shall receive 8 points. If the total number of points calculated for the studies is more than 40, the total number of points for the element quality shall be 40, as the maximum number of points. For proving the requirements for the element quality, the economic operators shall also submit: - printed materials from the magazine in which the randomized studies are published or to provide the internet link through which the authenticity of the submitted document can be checked. ORG-0001 ORG-0001 https://e-nabavki.gov.mk ORG-0001 ORG-0001 90 ORG-0001 ORG-0001 MKD true true required true 2026-09-30+02:00 12:00:00+02:00 2026-09-24+02:00 12:00:00+02:00 2026-09-30+02:00 12:00:00+02:00 https://e-nabavki.gov.mk false none none 02-667/11 A coronary cobalt-chromium stent with a permanent polymer, elastomer, featuring 4 markers, two positioned proximally and two distally, with a WZ stent design and a vessel wall imprint of 40 μm for the Z strut and 72 μm for the W strut with an exceptional radiopacity, with a metal spring tip at the catheter, enabling easier navigation through the blood vessels and improved visibility, coated with a A coronary cobalt-chromium stent with a permanent polymer, elastomer, featuring 4 markers, two positioned proximally and two distally, with a WZ stent design and a vessel wall imprint of 40 μm for the Z strut and 72 μm for the W strut with an exceptional radiopacity, with a metal spring tip at the catheter, enabling easier navigation through the blood vessels and improved visibility, coated with a drug from the LIMUS family, with diameters ranging from 2.25 to 4.00 mm and length from 8 to 44 mm, or equivalent supplies 50 In order to qualify, the economic operator shall confirm the required technical and professional competence for fulfilling the subject agreement for public procurement via the following minimal conditions: - offering medical devices and materials that are in accordance with the requirements in the technical specifications. The economic operator proves the fulfillment of the minimal conditions by submitting: - catalogues for each part of the subject of procurement must be submitted along with the offer. These catalogues shall contain a detailed description of the characteristics of the offered goods in either Macedonian or English, and those characteristics shall be clearly marked in accordance with the requirements in the technical specifications (a scanned catalogue attached on ESPP). 18536 33111710 Ohrid MK003 MKD 12

Related documents

Record · ID 655677 · SHA-256 2c0cc22d8970f2c6
Conceptio Open Knowledge Archive — every document is proof-bundled with source, license, and retrieval metadata.