Accuracy of Core Body Temperature Measurement Depending on Oesophageal Probe Tip Location
Background An accurate measurement of the core body temperature (CBT) is of pivotal importance in the management of severely hypothermic patients. For instance, triage decisions for or against extracorporeal rewarming of hypothermic patients in cardiac arrest strongly depend on CBT. CBT measurement with an oesophageal probe is currently considered the gold standard in hypothermic patients with a secured airway in the prehospital setting, with the tip of the probe placed into the distal third of the oesophagus (i.e., posteriorly to the heart and distal to the tracheal bifurcation). However, the correct placement of the probe tip cannot be verified in the prehospital setting, and it is unknown how incorrect placement affects temperature readings. Hypothesis and aim The investigators hypothesise that an incorrect placement of the oesophageal temperature probe tip could lead to inaccurate measurements (i.e., temperature readings not reflecting the real CBT). Particularly, a tip location too high in the oesophagus in close proximity to the trachea could lead to falsely low temperature readings, especially when the patient is ventilated with cold air. The aim of the proposed study is to investigate the influence of oesophageal temperature probe tip location on CBT measurement. Methods Experimental, interventional study on 16 healthy volunteers. During the test oesophageal temperature is measured while participants are breathing ambient air first at 20°C (baseline) followed by cold (-20°C) ambient air in supine position for 20 minutes each test in an environmental simulator (terraXcube). Each participant repeats the 20-min test two times with the oesophageal temperature probe tip placed either in the lower third of the oesophagus (i.e., correct position) or too high in the oesophagus, i.e. behind the trachea.
Conceptio Open Archive
Analyze & explore related research in Conceptio
Connect this record directly into your research workflow or AI agent. Explore citations across open repositories, query full text, and export structured proof bundles.
This document is indexed with metadata only: full text is not available in the archive for this record. Open the official source ↗
Related documents
- Optimal Positioning of Nasopharyngeal Temperature Probes#829818
- Feasibility and Accuracy of Core Temperature Measurements Using the Esophageal Temperature Probe Inserted Through the Gastric Lumen of Supraglottic Airway Device in Pediatrics#1151290
- Clinical Accuracy Validation of the Moni-Patc Temperature Monitoring Patch During Surgery (Compared With Esophageal and Bladder Temperature)#859981
- Estimation of the Difference Between the Temperature of the Peritoneal Microenvironment and the Central Body Temperature During Laparoscopic Surgery. Prospective Observational Study#833554
- Core Body Temperature Measurement During Hot and Cold Environmental Exposure#1057731
Record · ID 838232
Retrieved via Conceptio: every document is proof-bundled with source, license, and retrieval metadata.
Retrieved via Conceptio: every document is proof-bundled with source, license, and retrieval metadata.
Bring this data into your agent: Connect via MCP or API · 20 free credits to start · no card required
Read the Docs → · View CLI source on GitHub · Conceptio Open Knowledge Archive
Read the Docs → · View CLI source on GitHub · Conceptio Open Knowledge Archive