ClinicalTrials.gov
public full text
Public Domain
Safety and Efficacy of DCB Therapy for de Novo Lesions Under the Guidance of QFR in CHD Patients (UNIQUE-DCB-I Study )
Since Gruntzig successfully performed percutaneous coronary balloon angioplasty in 1977, percutaneous coronary intervention has developed rapidly. From bare metal stents to drug-eluting stents (DES), the symptoms and prognosis of patients with coronary heart disease (CHD) have been greatly improved. Although DES has reduced the probability of in-stent restenosis (ISR) and thrombosis compared with BMS since its clinical application, it can not completely solve this problem. Even if the new generation of DES requires revascularization, the incidence of ISR is still as high as 5%-10%. DES treatment is associated with delayed endothelial healing, late acquired poor stent adherence and new atherosclerosis, which lead to late ISR and thrombosis. In addition, DES is still not ideal for the treatment of small vessel disease, diffuse long lesion and bifurcation lesion. Therefore, drug coated balloon (DCB) has attracted people's attention. Balloon-loaded antiproliferative drugs can fully release the drugs to the vascular wall during balloon dilation, which can inhibit the restenosis process from the beginning of injury, and show good efficacy and safety in some specific lesions. Many clinical studies have shown that DCB has good efficacy and safety in some specific lesions (ISR, small vessel disease, bifurcation disease, in situ lesion). Especially in the treatment of ISR, researchers believe that its efficacy is not inferior to DES, and it has the advantage of non-metal residues. Quantitative flow ratio (QFR) is the second generation FFR detection method based on angiographic images. The diagnostic accuracy of QFR 0.80 for myocardial ischemic stenosis was 92.7%. Compared with QCA, the positive predictive value and negative predictive value of QFR were also significantly better than those of QCA. The latest FAVOR II results also confirm that QFR is more sensitive and specific in diagnosing myocardial ischemia caused by coronary artery stenosis than QCA, and confirm the feasi
Conceptio Open Archive
Analyze & explore related research in Conceptio
Connect this record directly into your research workflow or AI agent. Explore citations across open repositories, query full text, and export structured proof bundles.
This document is indexed with metadata only: full text is not available in the archive for this record. Open the official source ↗
Related documents
- AGENT DCB STANCE: Safety and Effectiveness Study of AGENT Drug-Coated Balloon Compared to Standard of Care Percutaneous Coronary Intervention (PCI) Treatment for de Novo Coronary Lesions#868063
- DCB Under the Guidance of OCT in STEMI#830236
- The Value of IVL Compared To OPN Non-Compliant Balloons for Treatment of RefractorY Coronary Lesions (VICTORY) Trial#1060497
- Safety and Efficacy of Drug-Coated Balloon for De-novo Lesions in Patients With Acute Coronary Syndromes (DCB-ACS)#1072317
- Optimized Duration of Clopidogrel Therapy Following Treatment With the Endeavor - Optimize Trial#1173436
Record · ID 843745
Retrieved via Conceptio: every document is proof-bundled with source, license, and retrieval metadata.
Retrieved via Conceptio: every document is proof-bundled with source, license, and retrieval metadata.
Bring this data into your agent: Connect via MCP or API · 20 free credits to start · no card required
Read the Docs → · View CLI source on GitHub · Conceptio Open Knowledge Archive
Read the Docs → · View CLI source on GitHub · Conceptio Open Knowledge Archive