Comparison of Efficacy and Safety of Two Biphasic Defibrillators in Cardioversion of Atrial Fibrillation
Background: Biphasic truncated exponential (BTE) waveforms are standard for cardiac defibrillation and synchronized cardioversion up to date. BTE waveforms differ by design characteristics and technologies for pulse commutation (rectilinear, standard truncated exponential, pulsed). Clinical evaluation of BTE waveforms can be planned during cardioversion (CVS) as a well-established procedure of atrial fibrillation patients who are able to give consent and also present a more controlled population. Scarce studies have been found to present the relative efficacy and safety of different BTE waveforms during CVS. The validity of significantly deviating results of the pulsed waveform in one CVS study is questionable. Objective: To compare the CVS efficacy and safety two different biphasic defibrillators - a standard truncated exponential waveform and a pulsed biphasic waveform. Experimental design: Patients will be recruited at the Intensive Cardiology Care Unit (ICCU), Cardiology Clinic, University National Heart Hospital (NHH), Sofia, Bulgaria, underwent the pre-CVS medical exams and check for eligibility. All eligible patients will sign a written informed consent prior to the CVS and will receive the standard hospital procedures during CVS, accepted in the NHH, and approved by the NHH Local Ethic Committee. Atrial fibrillation patients will be alternatively randomized to CVS using one of the two defibrillators, following the same energy selection protocol in both defibrillators. The statistical power analysis will consider a non-inferiority comparison between the cumulative energy actually delivered by both defibrillators. The secondary CVS outcome measures are: the cumulative success rate (measured at 1 minute post-shock) and number of delivered shocks. Delivered energy will be measured during each shock with a dedicated pulse recording device (approved by the NHH Local Ethic Committee). Heart rhythm will be monitoring in continuously recorded peripheral ECG. Th
Conceptio Open Archive
Analyze & explore related research in Conceptio
Connect this record directly into your research workflow or AI agent. Explore citations across open repositories, query full text, and export structured proof bundles.
This document is indexed with metadata only: full text is not available in the archive for this record. Open the official source ↗
Related documents
- Quality of the Cardio-pulmonary Resuscitation#1137946
- A Study Evaluating the Effectiveness and Safety of Pulsed Field Ablation Using the FARAPULSE™ System for Electrical Isolation of Pulmonary Veins and Superior Vena Cava#904333
- Defibrillation Testing During Implantable Cardioverter Defibrillator (ICD) Replacement#828543
- Early complications and long-term outcome of patients treated with a Subcutaneous Cardioverter-Defibrillator: temporal trends and clinical implications of the anesthetic strategies adopted at implant#291666
- T-wave Alternans and Intrathoracic Impedance Measurements#899864
Record · ID 872129
Retrieved via Conceptio: every document is proof-bundled with source, license, and retrieval metadata.
Retrieved via Conceptio: every document is proof-bundled with source, license, and retrieval metadata.
Bring this data into your agent: Connect via MCP or API · 20 free credits to start · no card required
Read the Docs → · View CLI source on GitHub · Conceptio Open Knowledge Archive
Read the Docs → · View CLI source on GitHub · Conceptio Open Knowledge Archive