Airway Flow of RAM Cannula With BCPAP in Infants
The RAM Cannula interface is used as routine interface for newborn infants receiving CPAP treatment for respiratory distress. Compared to the standard systems that have been used for more than 50 years, the interface has high resistance and has not been extensively studied. The delivered quality of the CPAP support is likely to be negatively affected by the interface resistance. We hypothesise that exhalations through the device is uncommon and that the interface resistance restricts flow from the patient. If expiratory flows are uncommon the RAM interface provide support clinically comparable to other systems based on unidirectional flow such as humidified high-flow cannula. This is a cross-sectional, observational study (no intervention) in newborn infants that are clinically stable and on respiratory support with the RAM interface connected to a bCPAP circuit. This is the most common support in the Phu San neonatal unit. The time needed for data collection is short and collection is expected to take approximately five minutes (less than 15 minutes) in a quiet infant. The collection can be planned to minimize disturbances for the infant, parents and staff. For example, the busiest times of the day can be avoided to not intervene with daily care, ward rounds or examinations of the infant. Data on flow and pressure will be collected within the respiratory support circuit at the connection to the RAM interface. The measurements are passive, and no tests or manipulation of the infant is planned. There will be brief interruptions (\<1 min) in respiratory support when the meters are connected. Similar interruptions are very common and occurs several times per day during normal care. Data will be collected in case report forms (CRF) with REDCap electronic data capture tool. All personal identifiers will be removed before data export from REDCap and further analysis only using enrolment numbers. Background variables describing the pregnancy, delivery and the infant w
Conceptio Open Archive
Analyze & explore related research in Conceptio
Connect this record directly into your research workflow or AI agent. Explore citations across open repositories, query full text, and export structured proof bundles.
This document is indexed with metadata only: full text is not available in the archive for this record. Open the official source ↗
Related documents
- Comparison of the Results of Transcutaneous Carbon Dioxide and Oxygen Pressure in Premature Neonates Who Underwent MIST Under HHHFNC or Nasal CPAP Methods#1162832
- LISA in the Delivery Room for Extremely Preterm Infants#859295
- Neotech RAM Cannula Versus Conventional Binasal Prong Continuous Positive Airway Pressure (CPAP) to Treat Respiratory Distress in Low Birth Weight Neonates#884682
- Evaluation of Acclimate Feature for Positive Airway Pressure (PAP) Therapy#841411
- mHealth to Screen for Neonatal Jaundice in Low-resource Mexican Settings: a Feasibility Study#894230
Record · ID 884738
Retrieved via Conceptio: every document is proof-bundled with source, license, and retrieval metadata.
Retrieved via Conceptio: every document is proof-bundled with source, license, and retrieval metadata.
Bring this data into your agent: Connect via MCP or API · 20 free credits to start · no card required
Read the Docs → · View CLI source on GitHub · Conceptio Open Knowledge Archive
Read the Docs → · View CLI source on GitHub · Conceptio Open Knowledge Archive