ClinicalTrials.gov
public full text
Public Domain
Comparison of Body Hydration State in Hemodialysis Patients
Estimation of hydration state in dialysis patients is a major challenge in clinical practice. Although many methods have been studied, none have been established yet for clinical routine practice. The investigators have developed a method, using segmental and calf bioimpedance spectroscopy (cBIS) techniques to measure body hydration. The device we used based on the FDA-approved Hydra 4200 (Xitron Technologies, San Diego, CA). The Hydra 4200 was initially developed to measure whole body and segmental body fluid volumes but Hydra is approved only for measuring healthy subjects. The cBIS monitors hydration state by continuously measuring change in resistance and resistivity in the calf during hemodialysis (HD) or it can be used for simple measurement before, during and after dialysis. Preliminary results in clinical studies have shown that optimal hydration state of HD patients may be determined by the calf method. This study aims to compare the Hydra 4200 to two other devices: the FDA approved ZOE (100 kHz) Fluid Status Monitor (Noninvasive Medical Technologies, Inc, Las Vegas) and a modified version ZOE 5 kHz. The modified ZOE monitor (ZOE (5 kHz)) delivers frequency of 5 kHz and 0.8 mA current instead of 100 kHz and 2 mA. The subjects of this study include a group of hemodialysis patients and a group of healthy controls. The healthy controls are used to identify a normal range within the healthy population for each method. Each hemodialysis patient will be studied twice in different hydration state. The study will not change the procedure of the patient's dialysis treatment. Since all devices are based on noninvasive bioimpedance technique, this study has minimal risk.
Conceptio Open Archive
Analyze & explore related research in Conceptio
Connect this record directly into your research workflow or AI agent. Explore citations across open repositories, query full text, and export structured proof bundles.
This document is indexed with metadata only: full text is not available in the archive for this record. Open the official source ↗
Related documents
- Application of Bioimpedance Spectroscopy in Taiwan Dialysis Patients#884354
- Detection of Patients With Abnormal Water Distribution Based on Bioelectrical Impedance Analysis (BIA)#887362
- Body Composition Monitor Among Daily Home Dialysis With Low Flow Dialysate#826651
- Body Fluid Dynamics in Hemodialysis Patients, an Estimation of Dry Weight#414384
- Assessment of Hydration Status Using Bioelectrical Impedance Vector Analysis#1031654
Record · ID 898058
Retrieved via Conceptio: every document is proof-bundled with source, license, and retrieval metadata.
Retrieved via Conceptio: every document is proof-bundled with source, license, and retrieval metadata.
Bring this data into your agent: Connect via MCP or API · 20 free credits to start · no card required
Read the Docs → · View CLI source on GitHub · Conceptio Open Knowledge Archive
Read the Docs → · View CLI source on GitHub · Conceptio Open Knowledge Archive