ClinicalTrials.gov
public full text
Public Domain
RDS MultiSense® SpO2 Validation Study
The purpose of this clinical study is to validate the oxygen saturation (SpO2) accuracy of the RDS MultiSense® Pulse Oximetry during non-motion conditions over the range of 70-100% arterial oxygen saturation (SaO2) as compared to arterial blood samples assessed by measuring carbon monoxide (CO) bound to hemoglobin by CO-Oximetry. Additionally, data will be collected for heart rate accuracy as compared to reference ECG. The end goal is to provide supporting documentation for the SpO2 and heart rate accuracy validation for RDS MultiSense® Pulse Oximetry. A minimum of 10 healthy adult male and female participants, ranging in age and pigmentation from light to dark, will be enrolled in the study to meet the study design requirements defined by International Organization for Standardization ISO 80601-2-61:2017: corrected version 2018-02 and by the FDA's Guidance for Pulse Oximeters (March 4, 2013). The participants will have an arterial catheter placed in the radial artery to allow for simultaneous blood samples during stable plateaus of induced hypoxic levels. The investigational device will be placed on the placed on the thorax of the participants (patch on the upper back and external electrode on the right pectoral) per the instructions for use. Simultaneous data collection will be set up for the system under test and control oximeter.
Conceptio Open Archive
Analyze & explore related research in Conceptio
Connect this record directly into your research workflow or AI agent. Explore citations across open repositories, query full text, and export structured proof bundles.
This document is indexed with metadata only: full text is not available in the archive for this record. Open the official source ↗
Related documents
- OxyGap : Comparison Between Different Pulse Oximeter and With the Arterial Blood Gase#838947
- In Vivo Pulse Oximeter Validation Study#1137159
- Advanced Prediction of Respiratory Depression Episode Using the Linshom Continuous Predictive Respiratory Sensor#831804
- Validation of Ballistocardiographic Biosensors and Other Hemodynamic Measures for Healthy Subjects#863113
- SpO2 Infant and Pediatric Study#1174071
Record · ID 898648
Retrieved via Conceptio: every document is proof-bundled with source, license, and retrieval metadata.
Retrieved via Conceptio: every document is proof-bundled with source, license, and retrieval metadata.
Bring this data into your agent: Connect via MCP or API · 20 free credits to start · no card required
Read the Docs → · View CLI source on GitHub · Conceptio Open Knowledge Archive
Read the Docs → · View CLI source on GitHub · Conceptio Open Knowledge Archive