ClinicalTrials.gov
public full text
Public Domain
A Prospective, Multicenter, Single-arm Study to Evaluate a Transcatheter Aortic Valve System Safety and Efficacy for the Treatment of Patients With Severe Aortic Stenosis
Trial Title: Prospective, multicenter, single-arm target value clinical trial to evaluate the safety and efficacy of a transcatheter aortic valve system in the treatment of patients with severe aortic stenosis Test device: Transcatheter aortic valve system. Pilot Phase: Clinical Validation of Class III Medical Devices. Study design: prospective, multicenter, single-group target value. Sample size: 120 cases. Intended Use: The Transcatheter Aortic Valve System is indicated for patients with a diagnosis of severe aortic stenosis by the Comprehensive Heart Team. Objective: This clinical trial is a prospective, multicenter, single-arm study to evaluate the safety and efficacy of the transcatheter aortic valve system in the treatment of patients with severe aortic stenosis. Primary endpoint: 12-month postoperative all-cause mortality All-cause deaths include cardiac death and non-cardiac death. Secondary Endpoints: 1. Device success rate 2. Procedural success rate 3. Delivery system performance 4. Retrieval system performance (e.g. using a recycling system) 5. Exchange system performance 6. Valvular function at Immediately postoperative, 7 days/at discharge, 30 days, 6 months, 12 months, 2-5 years follow-up: valve stenosis, regurgitation, valve function (e.g., opening area, pressure gradient), paravalvular leakage 7. Improvement in quality of life at 30 days, 6 months, 12 months postoperatively 8. Improvement in cardiac function at 7 days/at discharge, 30 days, 6 months, 12 months, 2-5 years postoperatively Experimental design: This trial is a prospective, multicenter, single-group clinical study with a target value to evaluate the Transcatheter Aortic Valve system Safety and efficacy in the treatment of patients with severe aortic stenosis with 12 months of All-cause mortality after transcatheter aortic valve implantation. The mortality rate was the primary study endpoint, and after statistical assumptions and sample size calculations, 120 patients were planned to
Conceptio Open Archive
Analyze & explore related research in Conceptio
Connect this record directly into your research workflow or AI agent. Explore citations across open repositories, query full text, and export structured proof bundles.
This document is indexed with metadata only: full text is not available in the archive for this record. Open the official source ↗
Related documents
- A Comparison of Transcatheter Heart Valves in High Risk Patients With Severe Aortic Stenosis: The CHOICE Trial#979705
- Myval Global Study of Myval™ THV Series Implanted in Patients With Native Severe Aortic Valve Stenosis.#813060
- RHEIA (Randomized researcH in womEn All Comers With Aortic Stenosis)#1126943
- 5 Year Observation of Patients With PORTICO Valves#1140923
- Clinical Evaluation of MDT-2111 in Subjects With Small Aortic Annuli and Symptomatic Severe Aortic Stenosis#805697
Record · ID 900443
Retrieved via Conceptio: every document is proof-bundled with source, license, and retrieval metadata.
Retrieved via Conceptio: every document is proof-bundled with source, license, and retrieval metadata.
Bring this data into your agent: Connect via MCP or API · 20 free credits to start · no card required
Read the Docs → · View CLI source on GitHub · Conceptio Open Knowledge Archive