Using the Blood Pressure TRU in Clinical Settings: a Knowledge Translation Study
Context: Use of automated blood pressure (BP) measurement devices in the office setting is increasingly recognized as superior to manual BP measurement. Current recommendations are to have the patient alone in a quiet room, with no interactions with health care professionals during the readings. However, this may not be practical in primary care offices where the exam rooms are constantly being used. Objective: To compare measurements with an automated BP device in private examination rooms with measurements in non-private areas of a primary care office. Design: Randomized controlled trial with cross-over. Setting: Community based primary care office participating in the NorTReN Practice Based Research Network in Toronto, Ontario. Participants: Fifty consecutive consenting patients over the age of 18 having their BP checked as part of their routine care. Intervention: Patients will be randomly allocated to either automated BP measurement in an exam room, or in a non-private area of the clinic. After being tested in the first location they will subsequently be tested in the second location with the same device. Main outcome measure: The primary outcome measure is a comparison between the mean systolic values of the automated BP measurements in the two office areas. The investigators will use the t-test for paired samples. The secondary outcome is a comparison of systolic values for patients with previously documented hypertension. The investigators define a clinically meaningful result as a difference of 5 mmHg or more in systolic BP. Conclusion: New technology is more readily adopted if barriers to use are minimized. If the investigators find no differences in BP readings between office locations, physicians will then have the convenience of an additional office area to implement the automated BP measurement device.
Conceptio Open Archive
Analyze & explore related research in Conceptio
Connect this record directly into your research workflow or AI agent. Explore citations across open repositories, query full text, and export structured proof bundles.
This document is indexed with metadata only: full text is not available in the archive for this record. Open the official source ↗
Related documents
- Blood Pressure Monitor Clinical Test (Cuff Range: 13.5 Cm-22cm)#835255
- Telemonitoring of Blood Pressure in Local Pharmacies#67720
- Non-Invasive Blood Pressure Monitoring in ICU Patients Using the DARE Device#829653
- Blood Pressure Monitor Clinical Test (Cuff Range: 13.5cm-19.5cm)#837782
- Blood Pressure Monitor Clinical Test (Cuff Range: 22 Cm-36cm)#834544
Record · ID 915122
Retrieved via Conceptio: every document is proof-bundled with source, license, and retrieval metadata.
Retrieved via Conceptio: every document is proof-bundled with source, license, and retrieval metadata.
Bring this data into your agent: Connect via MCP or API · 20 free credits to start · no card required
Read the Docs → · View CLI source on GitHub · Conceptio Open Knowledge Archive
Read the Docs → · View CLI source on GitHub · Conceptio Open Knowledge Archive