ClinicalTrials.gov
public full text
Public Domain
DANISH-CRT - Does Electric Targeted LV Lead Positioning Improve Outcome in Patients With Heart Failure and Prolonged QRS
Heart failure is a leading cause of morbidity and mortality. Cardiac resynchronization therapy (CRT) is a well-established treatment for patients with symptomatic heart failure in spite of optimised medical treatment (OMT), reduced left ventricular pump function with left ventricular ejection fraction (LVEF) ≤ 35% and prolonged activation of the ventricles (bundle branch block: BBB). CRT is established by implanting an advanced pacemaker system with three leads in the right atrium, right ventricle, and in the coronary sinus (CS) for pacing the left ventricle (LV), and often is combined with an implantable defibrillator (ICD) function. On average, CRT treatment improves longevity, quality of life and functional class, and reduces heart failure symptoms. Thus, at present, CRT is indicated for heart failure patients on OMT with BBB or chronic right ventricular (RV) pacing. It is, however, a significant problem that 30-40% of CRT patients do not benefit measurably - showing symptomatic improvement or improved cardiac pump function - from this therapy (socalled non-responders). LV lead placement is one of the major determinants of beneficial effect from CRT. Observational studies and three randomised trials with small sample sizes indicate that targeted placement of the LV lead towards a late activated segment of the LV may be associated with improved outcome. Based on this literature, some physicians already search for late activation when positioning the LV lead. However, such a strategy was never tested in a controlled trial with a sample size sufficient to investigate important clinical outcomes. Detailed mapping for a late activation may increase operating times and infection risk, result in use of more electrodes and wires, thereby increasing costs, and increase radiation exposure for patient and staff. Placement of the LV lead in late activated areas close to myocardial scar may even result in higher risk of arrhythmia and death. At present, it is completely un
Conceptio Open Archive
Analyze & explore related research in Conceptio
Connect this record directly into your research workflow or AI agent. Explore citations across open repositories, query full text, and export structured proof bundles.
This document is indexed with metadata only: full text is not available in the archive for this record. Open the official source ↗
Related documents
- High Intensity His Bundle Pacing in Heart Failure Patients With Narrow QRS Outcome Study#1104338
- Left Ventricular MultiSpot Pacing for CRT (iSPOT)#1093169
- Multi-lead ECG to Effectively Optimize Resynchronization Devices: New CRT Recipients#802813
- Investigation of Transvenous Versus Epicardial Left Ventricular Stimulation Technique#890331
- THE RELATİONSHİP BETWEEN BLOOD GAS PARAMETERS OBTAİNED FROM THE CORONARY SİNUS DURİNG THE PROCEDURE AND CRT RESPONSE İN PATİENTS WİTH HEART FAİLURE WHO UNDERWENT CRT IMPLANTATİON#857635
Record · ID 1231798
Retrieved via Conceptio: every document is proof-bundled with source, license, and retrieval metadata.
Retrieved via Conceptio: every document is proof-bundled with source, license, and retrieval metadata.
Bring this data into your agent: Connect via MCP or API · 20 free credits to start · no card required
Read the Docs → · View CLI source on GitHub · Conceptio Open Knowledge Archive
Read the Docs → · View CLI source on GitHub · Conceptio Open Knowledge Archive