ClinicalTrials.gov
public full text
Public Domain
Three Inflation Methods of Ambú Auragain™ and Its Adverse Effects
Laryngeal mask is a common supraglottic device (SGD) used in the daily practice for airway management. Consecutive generations have permitted an expansion of its use. At the moment, the SGD is being used in several situations, which include general anesthesia, cardiopulmonary resuscitation, and difficult airway management. To insert the SGD safely in these situations, the Fourth National Audit Project has encouraged the use of second-generation SGD equipped with the passage of a nasogastric tube. Ambu Auragain™ is a recent second-generation SGD with an incorporated gastric drainage channel and the capability of working as a conduit for tracheal intubation. It has higher leak pressure than the ones of first generation, which is a key marker of efficacy and safety of its use; a higher leak pressure suggests a better seal between the artificial airway and patient's airway. However, there are still few reports of which volume of cuff is the most appropriate for it use. The cuff inflating volume is not standardized and it is common practice to inflate the SGD cuff according to the manufacturer's recommendations, without using a manometer. A hyperinflation of the laryngeal mask cuff was associated with complications ranging from sore throat, or dysphagia and dysphonia, to more serious complications such as paralysis of the vocal cord, arytenoid cartilages dislocation, recurrent laryngeal nerve injury and hypoglossal nerve injury. Also, the excess of volume or pressure is related to poor ventilation and increase the risk of gastric insufflation. The aim of this study is to evaluate the best cuff inflation method, in order to limit the intracuff pressure beyond the recommended maximum pressure (PM \< 60 cmH2O) and to allows decrease the pharyngo-laryngeal complications. The Primary outcome is to compare three different cuff inflating methods using Auragain™ laryngeal mask during fibro bronchoscopy and endobronchial ultrasound (EBUS) procedures, and to control the intra
Conceptio Open Archive
Analyze & explore related research in Conceptio
Connect this record directly into your research workflow or AI agent. Explore citations across open repositories, query full text, and export structured proof bundles.
This document is indexed with metadata only: full text is not available in the archive for this record. Open the official source ↗
Related documents
- A Randomised Controlled Trial to Compare Two Supraglottic Airway Devices (Ambu AuraGain vs Air Q-3) in Terms of Performance Characteristics.#895993
- Combined Use of Glidescope With Fiber Optic Broncscopy Versus Fiber Optic Alone in Difficult Intubation#1320001
- Developing a Physiology-Pharmacodynamic Model of Rocuronium Dose and Cardiac Output to Investigate the Onset Time of Neuromuscular Relaxation#1086787
- Comparing the Efficiency of Three Third-generation Supraglottic Airways as an Intubation Route#843816
- Air-Q® SP Versus Air-Q® and I-gel: A Randomized Clinical Trial#827365
Record · ID 1384039
Retrieved via Conceptio: every document is proof-bundled with source, license, and retrieval metadata.
Retrieved via Conceptio: every document is proof-bundled with source, license, and retrieval metadata.
Bring this data into your agent: Connect via MCP or API · 20 free credits to start · no card required
Read the Docs → · View CLI source on GitHub · Conceptio Open Knowledge Archive
Read the Docs → · View CLI source on GitHub · Conceptio Open Knowledge Archive