ClinicalTrials.gov
public full text
Public Domain
The Measurement of Bladder Impedance and Heart Rate During Urodynamic Study
Purpose To measure the impedance of the bladder during the urodynamic study to see if changes in the impedance value occur as the bladder volume changes in pediatric patients aged 5-12 years along with its leg time. In addition, during the urodynamics test, the heart rate is measured at the same time to confirm the pulse change due to the filling of the bladder. -Background of the study (Method of identifying urinary bladder using impedance) In order to overcome the limitation of the method of checking the urinary volume in the bladder using ultrasound, the measurement of the impedance in the bladder is proposed as an alternative. Impedance measurement is non-invasive, very low cost, easy to measure and has a great advantage that it can be continuously measured in everyday life. In fact, early studies suggest that impedance measurement in the bladder is helpful in identifying urinary bladder capacity. On the other hand, there are two disadvantages to the urinary bladder identification method using impedance. One is the relative aspect that the impedance value changes according to the patient, and the other is the time lag time from the measurement point to the point when the impedance change appears. * In order to overcome this problem of impedance-based urinary bladder identification method, we measured impedance change according to real-time change of urinary volume in bladder during urodynamic study. * Background of the Invention (Pulse changes due to changes in urinary volume in bladder) It is known that when the urine enters the urinary bladder, the autonomic nervous system detects and regulates the heart rhythm, and the change of heart rate has not been reported in pediatric patients.
Conceptio Open Archive
Analyze & explore related research in Conceptio
Connect this record directly into your research workflow or AI agent. Explore citations across open repositories, query full text, and export structured proof bundles.
This document is indexed with metadata only: full text is not available in the archive for this record. Open the official source ↗
Related documents
- Detection of Patients With Abnormal Water Distribution Based on Bioelectrical Impedance Analysis (BIA)#887362
- Bladder Outlet Obstruction Observation Using Dynamic Urine Vibration "Holter"#804606
- Event-Based Estimation for Detrusor Pressure Using a Single Bladder Catheter Augmented with Abdominal Electromyography#1034963
- Comparison of Body Hydration State in Hemodialysis Patients#898058
- Body Composition Monitor Among Daily Home Dialysis With Low Flow Dialysate#826651
Record · ID 1439322
Retrieved via Conceptio: every document is proof-bundled with source, license, and retrieval metadata.
Retrieved via Conceptio: every document is proof-bundled with source, license, and retrieval metadata.
Bring this data into your agent: Connect via MCP or API · 20 free credits to start · no card required
Read the Docs → · View CLI source on GitHub · Conceptio Open Knowledge Archive
Read the Docs → · View CLI source on GitHub · Conceptio Open Knowledge Archive