Conceptio › Archive › NIST
NIST public full text Public Domain

NIST SP 1800-8: Securing Wireless Infusion Pumps in Healthcare Delivery Organizations

Gavin O'Brien (NIST); Sallie Edwards (MITRE); Kevin Littlefield (MITRE); Neil McNab (MITRE); Sue Wang (MITRE); Kangmin Zheng (MITRE) · National Institute of Standards and Technology (NIST)
NIST · Standards · License: Public Domain
Open Source ↗
cybersecurity-practicenist
Conceptio Open Archive

Analyze & explore related research in Conceptio

Connect this record directly into your research workflow or AI agent. Explore citations across open repositories, query full text, and export structured proof bundles.

NIST SPECIAL PUBLICATION 1800-8

Securing Wireless Infusion Pumps in Healthcare Delivery Organizations Includes Executive Summary (A); Approach, Architecture, and Security Characteristics (B), and How-To Guides (C)

Gavin O’Brien Sallie Edwards Kevin Littlefield Neil McNab Sue Wang Kangmin Zheng

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8

The first draft of this publication is available free of charge from: https://www.nccoe.nist.gov/sites/default/files/library/sp1800/hit-infusion-pump-nist-sp1800-8draft.pdf

NIST SPECIAL PUBLICATION 1800-8

Securing Wireless Infusion Pumps in Healthcare Delivery Organizations Includes Executive Summary (A); Approach, Architecture, and Security Characteristics (B); and How-To Guides (C)

Gavin O’Brien National Cybersecurity Center of Excellence Information Technology Laboratory Sallie Edwards Kevin Littlefield Neil McNab Sue Wang Kangmin Zheng The MITRE Corporation McLean, VA

August 2018

U.S. Department of Commerce Wilbur Ross, Secretary National Institute of Standards and Technology Walter G. Copan, Undersecretary of Commerce for Standards and Technology and Director

NIST SPECIAL PUBLICATION 1800-8A

Securing Wireless Infusion Pumps in Healthcare Delivery Organizations Volume A: Executive Summary

Gavin O’Brien National Cybersecurity Center of Excellence Information Technology Laboratory

Sallie Edwards Kevin Littlefield Neil McNab Sue Wang Kangmin Zheng The MITRE Corporation McLean, VA

August 2018 This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8

The first draft of this publication is available free of charge from: https://www.nccoe.nist.gov/sites/default/files/library/sp1800/hit-infusion-pump-nist-sp1800-8draft.pdf

Executive Summary ▪

Broad technological advancements have contributed to the Internet of Things (IoT) phenomenon, where physical devices now have technology that allow them to connect to the internet and communicate with other devices or systems. With billions of devices being connected to the internet, many industries, including healthcare, have leveraged, or are beginning to leverage, IoT devices to improve operational efficiency and enhance innovation.

▪

Medical devices, such as infusion pumps, were once standalone instruments that interacted only with the patient or medical provider. With technological improvements designed to enhance patient care, these devices now connect wirelessly to a variety of systems, networks, and other tools within a healthcare delivery organization (HDO)—ultimately contributing to the Internet of Medical Things (IoMT).

▪

As IoMT grows, cybersecurity risks have risen. According to the Association for the Advancement of Medical Instrumentation (AAMI) Technical Information Report 57 (TIR57), “this has created a new source of risk for [the] safe operation [of medical devices].” In particular, the wireless infusion pump ecosystem (the pump, the network, and the data stored in and on a pump) faces a range of threats, including unauthorized access to protected health information (PHI), changes to prescribed drug doses, and interference with a pump’s function.

▪

In addition to managing interconnected medical devices, HDOs oversee complex, highly technical environments, from back-office applications for billing and insurance services, supply chain and inventory management, and staff scheduling, to clinical systems, such as radiological and pharmaceutical support. In this intricate healthcare environment, HDOs and medical device manufacturers that share responsibility and take a collaborative, holistic approach to reducing cybersecurity risks of the infusion pump ecosystem can better protect healthcare systems, patients, PHI, and enterprise information.

▪

The National Cybersecurity Center of Excellence (NCCoE) at the National Institute of Standards and Technology (NIST) analyzed risk factors in and around the infusion pump ecosystem by using a questionnaire-based risk assessment. With the results of that assessment, the NCCoE then developed an example implementation that demonstrates how HDOs can use standards-based, commercially available cybersecurity technologies to better protect the infusion pump ecosystem, including patient information and drug library dosing limits.

CHALLENGE Technology improvements happen rapidly across all sectors. For organizations focused on streamlining operations and delivering high-quality patient care, it can be difficult to take advantage of the latest technological advances, while also ensuring that new medical devices or applications are secure. For many HDOs, this can result in improperly configured information technology networks and components that increase cybersecurity risks. Unlike prior medical devices that were once standalone instruments, today’s wireless infusion pumps connect to a variety of healthcare systems, networks, and other devices. Although connecting infusion pumps to point-of-care medication systems and electronic health records (EHRs) can improve healthcare delivery processes, using a medical device’s connectivity capabilities can create significant cybersecurity risk, which could lead to operational or safety risks. Tampering, intentional or otherwise, with the NIST SP 1800-8A: Securing Wireless Infusion Pumps This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

1

wireless infusion pump ecosystem can expose a healthcare provider’s enterprise to serious risks, such as the following examples: ▪

access by malicious actors

▪

loss or corruption of enterprise information and patient data and health records

▪

a breach of PHI

▪

loss or disruption of healthcare services

▪

damage to an organization’s reputation, productivity, and bottom-line revenue

As IoMT grows, with an increasing number of infusion pumps connecting to networks, the vulnerabilities and risk factors become more critical, as they can expose the pump ecosystem to external attacks, compromises, or interference.

SOLUTION The NCCoE has developed cybersecurity guidance, NIST Special Publication (SP) 1800-8: Securing Wireless Infusion Pumps, by using standards-based commercially available technologies and industry best practices to help HDOs strengthen the security of the wireless infusion pump ecosystem within healthcare facilities. This NIST cybersecurity publication provides best practices and detailed guidance on how to manage assets, protect against threats, and mitigate vulnerabilities by performing a questionnaire-based risk assessment. In addition, the security characteristics of the wireless infusion pump ecosystem are mapped to currently available cybersecurity standards and the Health Insurance Portability and Accountability Act (HIPAA) Security Rule. Based on our risk assessment findings, we apply security controls to the pump’s ecosystem to create a “defense-in-depth” solution for protecting infusion pumps and their surrounding systems against various risk factors. Ultimately, we show how biomedical, networking, and cybersecurity engineers and IT professionals can securely configure and deploy wireless infusion pumps to reduce cybersecurity risk. While the NCCoE used a suite of commercial products to address this challenge, this guide does not endorse these particular products, nor does it guarantee compliance with any regulatory initiatives. Your organization's information security experts should identify the products that will best integrate with your existing tools and IT system infrastructure. Your organization can adopt this solution or one that adheres to these guidelines in whole, or you can use this guide as a starting point for tailoring and implementing parts of a solution.

BENEFITS The NCCoE’s practice guide to securing wireless infusion pumps in HDOs can help your organization: ▪

reduce cybersecurity risk, and potentially reduce impact to safety and operational risk, such as the loss of patient information or interference with the standard operation of a medical device

▪

develop and execute a defense-in-depth strategy that protects the enterprise with layers of security to avoid a single point of failure and provide strong support for availability

NIST SP 1800-8A: Securing Wireless Infusion Pumps This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

2

▪

implement current cybersecurity standards and best practices, while maintaining the performance and usability of wireless infusion pumps

SHARE YOUR FEEDBACK You can view or download the guide at https://www.nccoe.nist.gov/projects/use-cases/medical-devices. Help the NCCoE make this guide better by sharing your thoughts with us as you read the guide. If you adopt this solution for your own organization, please share your experience and advice with us. We recognize that technical solutions alone will not fully enable the benefits of our solution, so we encourage organizations to share lessons learned and best practices for transforming the processes associated with implementing this guide. To provide comments or to learn more by arranging a demonstration of this example implementation, contact the NCCoE at hit_nccoe@nist.gov.

TECHNOLOGY PARTNERS/COLLABORATORS Organizations participating in this project submitted their capabilities in response to an open call in the Federal Register for all sources of relevant security capabilities from academia and industry (vendors and integrators). The following respondents with relevant capabilities or product components (identified as “Technology Partners/Collaborators” herein) signed a Cooperative Research and Development Agreement (CRADA) to collaborate with NIST in a consortium to build this example solution.

Certain commercial entities, equipment, products, or materials may be identified by name or company logo or other insignia in order to acknowledge their participation in this collaboration or to describe an experimental procedure or concept adequately. Such identification is not intended to imply special status or relationship with NIST or recommendation or endorsement by NIST or NCCoE; neither is it intended to imply that the entities, equipment, products, or materials are necessarily the best available for the purpose. The National Cybersecurity Center of Excellence (NCCoE), a part of the National Institute of Standards and Technology (NIST), is a collaborative hub where industry organizations, government agencies, and academic institutions work together to address businesses’ most pressing cybersecurity challenges. Through this collaboration, the NCCoE develops modular, easily adaptable example cybersecurity solutions demonstrating how to apply standards and best practices using commercially available technology.

LEARN MORE Visit https://www.nccoe.nist.gov nccoe@nist.gov 301-975-0200

NIST SP 1800-8A: Securing Wireless Infusion Pumps This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

3

NIST SPECIAL PUBLICATION 1800-8B

Securing Wireless Infusion Pumps in Healthcare Delivery Organizations Volume B: Approach, Architecture, and Security Characteristics

Gavin O’Brien National Cybersecurity Center of Excellence Information Technology Laboratory

Sallie Edwards Kevin Littlefield Neil McNab Sue Wang Kangmin Zheng The MITRE Corporation McLean, VA

August 2018 This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8

The first draft of this publication is available free of charge from: https://www.nccoe.nist.gov/sites/default/files/library/sp1800/hit-infusion-pump-nist-sp1800-8draft.pdf

DISCLAIMER Certain commercial entities, equipment, products, or materials may be identified in this document in order to describe an experimental procedure or concept adequately. Such identification is not intended to imply recommendation or endorsement by NIST or NCCoE, nor is it intended to imply that the entities, equipment, products, or materials are necessarily the best available for the purpose.

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

National Institute of Standards and Technology Special Publication 1800-8B, Natl. Inst. Stand. Technol. Spec. Publ. 1800-8B, 89 pages, (July 2018), CODEN: NSPUE2

FEEDBACK As a private-public partnership, we are always seeking feedback on our Practice Guides. We are particularly interested in seeing how businesses apply NCCoE reference designs in the real world. If you have implemented the reference design, or have questions about applying it in your environment, please email us at hit_nccoe@nist.gov.

National Cybersecurity Center of Excellence National Institute of Standards and Technology 100 Bureau Drive Mailstop 2002 Gaithersburg, MD 20899 Email: nccoe@nist.gov

NIST SP 1800-8B: Securing Wireless Infusion Pumps

i

NATIONAL CYBERSECURITY CENTER OF EXCELLENCE

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

The National Cybersecurity Center of Excellence (NCCoE), a part of the National Institute of Standards and Technology (NIST), is a collaborative hub where industry organizations, government agencies, and academic institutions work together to address businesses’ most pressing cybersecurity issues. This public-private partnership enables the creation of practical cybersecurity solutions for specific industries, as well as for broad, cross-sector technology challenges. Through consortia under Cooperative Research and Development Agreements (CRADAs), including technology partners—from Fortune 50 market leaders to smaller companies specializing in IT security—the NCCoE applies standards and best practices to develop modular, easily adaptable example cybersecurity solutions using commercially available technology. The NCCoE documents these example solutions in the NIST Special Publication 1800 series, which maps capabilities to the NIST Cyber Security Framework and details the steps needed for another entity to recreate the example solution. The NCCoE was established in 2012 by NIST in partnership with the State of Maryland and Montgomery County, Md. To learn more about the NCCoE, visit https://www.nccoe.nist.gov/. To learn more about NIST, visit https://www.nist.gov.

NIST CYBERSECURITY PRACTICE GUIDES NIST Cybersecurity Practice Guides (Special Publication Series 1800) target specific cybersecurity challenges in the public and private sectors. They are practical, user-friendly guides that facilitate the adoption of standards-based approaches to cybersecurity. They show members of the information security community how to implement example solutions that help them align more easily with relevant standards and best practices and provide users with the materials lists, configuration files, and other information they need to implement a similar approach. The documents in this series describe example implementations of cybersecurity practices that businesses and other organizations may voluntarily adopt. These documents do not describe regulations or mandatory practices, nor do they carry statutory authority.

ABSTRACT Medical devices, such as infusion pumps, were once standalone instruments that interacted only with the patient or medical provider. However, today’s medical devices connect to a variety of healthcare systems, networks, and other tools within a healthcare delivery organization (HDO). Connecting devices to point-of-care medication systems and electronic health records can improve healthcare delivery processes; however, increasing connectivity capabilities also creates cybersecurity risks. Potential threats include unauthorized access to patient health information, changes to prescribed drug doses, and interference with a pump’s function. The NCCoE at NIST analyzed risk factors in and around the infusion pump ecosystem by using a questionnaire-based risk assessment to develop an example implementation that demonstrates how HDOs can use standards-based, commercially available cybersecurity technologies to better protect the infusion pump ecosystem, including patient information and drug library dosing limits.

NIST SP 1800-8B: Securing Wireless Infusion Pumps

ii

This practice guide will help HDOs implement current cybersecurity standards and best practices to reduce their cybersecurity risk, while maintaining the performance and usability of wireless infusion pumps.

KEYWORDS authentication; authorization; digital certificates; encryption; infusion pumps; Internet of Things (IoT); medical devices; network zoning; pump servers; questionnaire-based risk assessment; segmentation; virtual private network (VPN); Wi-Fi; wireless medical devices This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

ACKNOWLEDGMENTS We are grateful to the following individuals for their generous contributions of expertise and time. Name

Organization

Arnab Ray

Baxter Healthcare Corporation

Pavel Slavin

Baxter Healthcare Corporation

Phillip Fisk

Baxter Healthcare Corporation

Raymond Kan

Baxter Healthcare Corporation

Tom Kowalczyk

B. Braun Medical Inc.

David Suarez

Becton, Dickinson and Company (BD)

Robert Canfield

Becton, Dickinson and Company (BD)

Rob Suarez

Becton, Dickinson and Company (BD)

Robert Skelton

Becton, Dickinson and Company (BD)

Peter Romness

Cisco

Kevin McFadden

Cisco

Rich Curtiss

Clearwater Compliance

Darin Andrew

DigiCert

Kris Singh

DigiCert

Mike Nelson

DigiCert

Chaitanya Srinivasamurthy

Hospira Inc., a Pfizer Company (ICU Medical)

Joseph Sener

Hospira Inc., a Pfizer Company (ICU Medical)

Chris Edwards

Intercede

NIST SP 1800-8B: Securing Wireless Infusion Pumps

iii

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

Name

Organization

Won Jun

Intercede

Dale Nordenberg

Medical Device Innovation, Safety & Security Consortium (MDISS)

Jay Stevens

Medical Device Innovation, Safety & Security Consortium (MDISS)

Carlos Aguayo Gonzalez

PFP Cybersecurity

Thurston Brooks

PFP Cybersecurity

Colin Bowers

Ramparts

Bill Hagestad

Smiths Medical

Axel Wirth

Symantec Corporation

Bryan Jacobs

Symantec Corporation

Bill Johnson

TDi Technologies, Inc.

Barbara De Pompa Reimers

The MITRE Corporation

Sarah Kinling

The MITRE Corporation

Marilyn Kupetz

The MITRE Corporation

David Weitzel

The MITRE Corporation

Mary Yang

The MITRE Corporation

The Technology Partners/Collaborators who participated in this build submitted their capabilities in response to a notice in the Federal Register. Respondents with relevant capabilities or product components were invited to sign a Cooperative Research and Development Agreement (CRADA) with NIST, allowing them to participate in a consortium to build this example solution. We worked with: Technology Partner/Collaborator

Build Involvement

Baxter Healthcare Corporation

• Sigma Spectrum™ Large Volume Pump (LVP) Version 8 • Sigma Spectrum Wireless Battery Module Version 8 • Sigma Spectrum Master Drug Library Version 8 • Care Everywhere Gateway Server Version 14

NIST SP 1800-8B: Securing Wireless Infusion Pumps

iv

Technology Partner/Collaborator

Build Involvement

B. Braun Medical Inc.

• Infusomat® Space Infusion System / Large-Volume Pumps • DoseTrac® Infusion Management Software / Infusion Pump Software

Becton, Dickinson and Company (BD) This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

• Alaris® 8015 Patient Care Unit (PCU) Version 9.19.2 • Alaris Syringe Module 8110 • Alaris LVP Module 8100 • Alaris Systems Manager Version 4.2 • Alaris System Maintenance (ASM) Version 10.19

Cisco

• Aironet 1600 Series Access Point (AIR-CAP1602I-A-K9) • Wireless LAN [Local Area Network] (WLC) Controller 8.2.111.0 • Identity Services Engine (ISE) • Adaptive Security Appliance (ASA) • Catalyst 3650 Switch

Clearwater Compliance

• IRM|Pro™ • IRM|Analysis™

DigiCert

CertCentral® management account / Certificate Authority

Hospira Inc., a Pfizer Company (ICU Medical)

• Plum 360™ Infusion System Version 15.10 • LifeCare PCA™ Infusion System Version 7.02 • Hospira MedNet™ Version 6.2

Intercede

MyID®

Medical Device Innovation, Safety & Security Consortium (MDISS)

Medical Device Risk Assessment Platform (MDRAP™)

PFP Cybersecurity

Device Monitor

Ramparts

Risk Assessment

NIST SP 1800-8B: Securing Wireless Infusion Pumps

v

Technology Partner/Collaborator

Build Involvement

Smiths Medical

• Medfusion® 3500 Version 5 Syringe Infusion System • PharmGuard® Toolbox Version 1.5 • Medfusion 4000 Wireless Syringe Infusion Pump • PharmGuard Toolbox 2 Version 3.0 use with Medfusion 4000 and 3500 Version 6 (US)

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

• PharmGuard Server Licenses, PharmGuard Server Enterprise Edition Version 1.1 • CADD®-Solis Ambulatory Infusion Pump • CADD-Solis Medication Safety Software Symantec Corporation

• Symantec Endpoint Protection (SEP) • Advanced Threat Protection: Network (ATP:N) • Data Center Security: Server Advanced (DCS:SA)

TDi Technologies, Inc.

NIST SP 1800-8B: Securing Wireless Infusion Pumps

ConsoleWorks®

vi

Contents

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

4.1.1

Industry Analysis of Risk ............................................................................................ 12

4.1.2

Questionnaire-Based Risk Assessment ...................................................................... 12

4.1.3

Assets ......................................................................................................................... 13

4.1.4

Threats ....................................................................................................................... 13

4.1.5

Vulnerabilities ............................................................................................................ 13

4.1.6

Risks ........................................................................................................................... 15

4.1.7

Recommendations and Best Practices ....................................................................... 17

4.2.1

Risk Mitigation ........................................................................................................... 17

NIST SP 1800-8B: Securing Wireless Infusion Pumps

vii

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

5.3.1

Network Controls ....................................................................................................... 38

5.3.2

Pump Controls ........................................................................................................... 52

5.3.3

Pump Server Controls ................................................................................................ 53

5.3.4

Enterprise-Level Controls........................................................................................... 56

7.2.1

Supported NIST Cybersecurity Framework Subcategories ........................................ 62

8.1.1

Test Case WIP-1 ......................................................................................................... 67

8.1.2

Test Case WIP-2 ......................................................................................................... 68

8.1.3

Test Case WIP-3 ......................................................................................................... 69

8.1.4

Test Case WIP-4 ......................................................................................................... 70

8.1.5

Test Case WIP-5 ......................................................................................................... 70

8.1.6

Test Case WIP-6 ......................................................................................................... 71

8.1.7

Test Case WIP-7 ......................................................................................................... 72

NIST SP 1800-8B: Securing Wireless Infusion Pumps

viii

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

ix

NIST SP 1800-8B: Securing Wireless Infusion Pumps

List of Figures Figure 4-1 Tiered Risk Management Approach [12] ............................................................................10 Figure 4-2 Relationship Between Security and Safety Risks [9] ...........................................................11 Figure 5-1 Basic System ......................................................................................................................37 Figure 5-2 Network Architecture with Segmentation..........................................................................42 Figure 5-3 Wi-Fi Management ............................................................................................................43 This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

Figure 5-4 Wi-Fi Authentication .........................................................................................................44 Figure 5-5 Wi-Fi Device Access ...........................................................................................................45 Figure 5-6 Network Access Control .....................................................................................................47 Figure 5-7 Remote Access VPN ...........................................................................................................49 Figure 5-8 Remote Access ..................................................................................................................50 Figure 5-9 External .............................................................................................................................51 Figure 5-10 Pump Server Protection ...................................................................................................56 Figure 5-11 Target Architecture ..........................................................................................................58 Figure 6-1 Asset Life Cycle [53] ...........................................................................................................59

List of Tables Table 4-1 Security Characteristics and Controls Mapping –- NIST Cyber Security Framework ..............20 Table 4-2 Products and Technologies .................................................................................................29 Table 8-1 Functional Test Plan............................................................................................................66 Table 8-2 Test Case WIP-1 ..................................................................................................................67 Table 8-3 Test Case WIP-2 ..................................................................................................................68 Table 8-4 Test Case WIP-3 ..................................................................................................................69 Table 8-5 Test Case WIP-4 ..................................................................................................................70 Table 8-6 Test Case WIP-5 ..................................................................................................................70 Table 8-7 Test Case WIP-6 ..................................................................................................................71 Table 8-8 Test Case WIP-7 ..................................................................................................................72

NIST SP 1800-8B: Securing Wireless Infusion Pumps

x

1 Summary Broad technological advancements have contributed to the Internet of Things (IoT) phenomenon, where physical devices now have technology that allow them to connect to the internet and communicate with other devices or systems. With billions of devices being connected to the internet, many industries, including healthcare, have or are beginning to leverage IoT devices to improve operational efficiency and enhance innovation. This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

Medical devices, such as infusion pumps, were once standalone instruments that interacted only with the patient or medical provider [1]. With technological improvements designed to enhance patient care, these devices now connect wirelessly to a variety of systems, networks, and other tools within a healthcare delivery organization (HDO)—ultimately contributing to the Internet of Medical Things (IoMT). The wireless infusion pump ecosystem (the pump, the network, and the data stored in and on a pump) faces a range of threats, including unauthorized access to protected health information (PHI), changes to prescribed drug doses, and interference with a pump’s function. In addition to managing interconnected medical devices, HDOs oversee complex, highly technical environments, from back-office applications for billing and insurance services, supply chain and inventory management, and staff scheduling, to clinical systems, such as radiological and pharmaceutical support. In this intricate healthcare environment, HDOs and medical device manufacturers that share responsibility and take a collaborative, holistic approach to reducing cybersecurity risks of the wireless infusion pump ecosystem can better protect healthcare systems, patients, protected health information (PHI), and enterprise information. The National Cybersecurity Center of Excellence (NCCoE) at the National Institute of Standards and Technology (NIST) developed an example implementation that demonstrates how HDOs can use standards-based, commercially available cybersecurity technologies to better protect the wireless infusion pump ecosystem, including patient information and drug library dosing limits. The NCCoE’s project has resulted in a NIST Cybersecurity Practice Guide, Securing Wireless Infusion Pumps in Healthcare Delivery Organizations, that addresses how to manage this challenge in clinical settings, with a reference design and example implementation. Our example solution starts with two types of risk assessments: an industry analysis of risk and a questionnaire-based-risk assessment. With the results of that assessment, we then used a “defense-in-depth” strategy to secure the pump, server components, and surrounding network to create a better-protected environment for wireless infusion pumps. The solution and architecture presented in this guide are built upon standards-based, commercially available products and represent one of many possible solutions and architectures. The example implementation can be used by any organization that is deploying wireless infusion pump systems and that is willing to perform its own risk assessment and implement controls based on its risk posture.

NIST SP 1800-8B: Securing Wireless Infusion Pumps

1

For ease of use of this volume, the following paragraphs provide a short description of each section of this volume. Section 1, Summary, presents the challenge addressed by the NCCoE project, with an in-depth look at our approach, the architecture, and the security characteristics that we used; the solution demonstrated to address the challenge; benefits of the solution; and the technology partners that participated in building, demonstrating, and documenting the solution. The Summary also explains how to provide feedback on this guide. This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

Section 2, How to Use This Guide, explains how readers like you—business decision makers, program managers, information technology (IT) professionals (e.g., systems administrators), and biomedical engineers—might use each volume of the guide. Section 3, Approach, offers a detailed treatment of the scope of the project, and describes the assumptions on which the security platform development was based, the risk assessment that informed platform development, and the technologies and components that industry collaborators gave us to enable platform development. Section 4, Risk Assessment and Mitigation, highlights the risks that we found, along with the potential response and mitigation efforts that can help lower risks for HDOs. Section 5, Architecture, describes the usage scenarios supported by project security platforms, including the NIST Cybersecurity Framework Functions supported by each component contributed by our collaborators. Section 6, Life Cycle Cybersecurity Issues, discusses cybersecurity considerations from a product-lifecycle perspective, including procurement, maintenance, and end of life. Section 7, Security Characteristics Analysis, provides details about the tools and techniques that we used to perform risk assessments pertaining to wireless infusion pumps. Section 8, Functional Evaluation, summarizes the test sequences that we employed to demonstrate security platform services, the NIST Cybersecurity Framework Functions to which each test sequence is relevant, and the NIST Special Publication (SP) 800-53 Revision 4 controls that applied to the functions being demonstrated. Section 9, Future Considerations, is a brief treatment of other applications that NIST might explore in the future to further support wireless infusion pump cybersecurity. The appendices provide acronym translations, references, a mapping of the wireless infusion pump project to the NIST Cybersecurity Framework Core (CFC), and a list of additional informative security references cited in the CFC.

NIST SP 1800-8B: Securing Wireless Infusion Pumps

2

1.1 Challenge The Food and Drug Administration (FDA) defines an external infusion pump as a medical device that delivers fluids into a patient’s body in a controlled manner, using interconnected servers or via a standalone drug library-based medication delivery system [1]. In the past, infusion pumps were standalone instruments that interacted only with the patient and the medical provider. Now, connecting infusion pumps to point-of-care medication systems and electronic health records (EHRs) can help improve healthcare delivery processes, but using a medical device’s connectivity capabilities can also create cybersecurity risk, which could lead to operational or safety risks. This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

Wireless infusion pumps are challenging to protect, for several reasons. They can be infected by malware, which can cause them to malfunction or operate differently than originally intended, and traditional malware protection could negatively impact the pump’s ability to operate efficiently. In addition, most wireless infusion pumps contain a maintenance default passcode. If HDOs do not change the default passcodes when provisioning pumps, and do not periodically change the passwords after pumps are deployed, this creates a vulnerability. This can make it difficult to revoke access codes (e.g., when a hospital employee resigns from the job). Furthermore, information stored inside infusion pumps must be properly secured, including data from drug library systems, infusion rates and dosages, or PHI [2], [3], [4], [5], [6]. Additionally, like other devices with operating systems and software that connect to a network, the wireless infusion pump ecosystem creates a large attack surface (i.e., the different points where an attacker could get into a system, and where they could exfiltrate data out), primarily due to vulnerabilities in operating systems, subsystems, networks, or default configuration settings that allow for possible unauthorized access [6], [7], [8]. Because many infusion pump models can be accessed and programmed remotely through a healthcare facility’s wireless network, this vulnerability could be exploited to allow an unauthorized user to interfere with the pump’s function, harming a patient through incorrect drug dosing or the compromise of that patient’s PHI. These risk factors are real, exposing the wireless pump ecosystem to external attacks, compromise, or interference [6], [8], [9]. Digital tampering, intentional or otherwise, with a wireless infusion pump’s ecosystem (the pump, the network, and data in and on the pump) can expose an HDO to critical risk factors, such as malicious actors; loss of data; a breach of PHI; loss of services; loss of health records; the potential for downtime; and damage to an HDO’s reputation, productivity, and bottom-line revenue. This practice guide helps you address your assets, threats, and vulnerabilities by demonstrating how to perform a questionnaire-based risk assessment survey. After you complete the assessment, you can apply security controls to the infusion pumps in your area of responsibility to create a defense-in-depth solution to protect them from cybersecurity risks.

NIST SP 1800-8B: Securing Wireless Infusion Pumps

3

1.2 Solution The NIST Cybersecurity Practice Guide Securing Wireless Infusion Pumps in Healthcare Delivery Organizations shows how biomedical engineers, networking engineers, security engineers, and IT professionals, using commercially available and open-source tools and technologies that are consistent with cybersecurity standards, can help securely configure and deploy wireless infusion pumps within HDOs.

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

In addition, the security characteristics of the wireless infusion pump ecosystem are mapped to currently available cybersecurity standards and the Health Insurance Portability and Accountability Act (HIPAA) Security Rule. In developing our solution, we used standards and guidance from the following sources: ▪

NIST Framework for Improving Critical Infrastructure Cybersecurity [10]

▪

NIST Risk Management Framework (RMF) [11], [12], [13]

▪

NIST SP 800-53 Revision 4: Security and Privacy Controls for Federal Information Systems and Organizations [14]

▪

Association for the Advancement of Medical Instrumentation (AAMI) Technical Information Report (TIR)57 [9]

▪

International Electrotechnical Commission Technical Report (IEC/TR) 80001-2: Application of risk management for IT-networks incorporating medical devices [15], [16], [17], [18], [19]

▪

FDA’s Postmarket Management of Cybersecurity in Medical Devices [3]

Ultimately, this practice guide: ▪

maps security characteristics to standards and best practices from NIST and other standards organizations, as well as to the HIPAA Security Rule [10], [14], [20], [21], [22]

▪

provides a detailed architecture and capabilities that address security controls

▪

provides a how-to for implementers and security engineers to recreate the reference design

▪

is modular and uses products that are readily available and interoperable with existing IT infrastructure and investments

NIST SP 1800-8B: Securing Wireless Infusion Pumps

4

1.3 Benefits The NCCoE’s practice guide to securing wireless infusion pumps in HDOs can help your organization:

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

▪

illustrate cybersecurity standards and best-practice guidelines to better secure the wireless infusion pump ecosystem, such as the hardening of operating systems, segmenting the network, file and program whitelisting, code-signing, and using certificates for both authorization and encryption, maintaining the performance and usability of wireless infusion pumps

▪

reduce risks from the compromise of information, including the potential for a breach or loss of PHI, as well as not allowing these medical devices to be used for anything other than the intended purposes

▪

document a defense-in-depth strategy to introduce layers of cybersecurity controls that avoid a single point of failure and provide strong support for availability. This strategy may include a variety of tactics: using network segmentation to isolate business units and user access; applying firewalls to manage and control network traffic; hardening and enabling device security features to reduce zero-day exploits; and implementing strong network authentication protocols and proper network encryption, monitoring, auditing, and intrusion detection systems (IDS) and intrusion prevention systems (IPS)

▪

highlight best practices for the procurement of wireless infusion pumps, by including the need for cybersecurity features at the point of purchase

▪

call upon industry to create new best practices for healthcare providers to consider when onboarding medical devices, with a focus on elements such as asset inventory, certificate management, device hardening and configuration, and a clean-room environment to limit the possibility of zero-day vulnerabilities

2 How to Use This Guide This NIST Cybersecurity Practice Guide demonstrates a standards-based reference design and provides users with the information they need to replicate NCCoE’s questionnaire-based risk assessment and the deployment of a defense-in-depth strategy. This reference design is modular and can be deployed in whole or in parts. This guide contains three volumes: ▪

NIST SP 1800-8A: Executive Summary

▪

NIST SP 1800-8B: Approach, Architecture, and Security Characteristics – what we built and why (you are here)

▪

NIST SP 1800-8C: How-To Guides – instructions for building the example solution

NIST SP 1800-8B: Securing Wireless Infusion Pumps

5

Depending on your role in your organization, you might use this guide in different ways: Business decision makers, including chief security and technology officers, will be interested in the Executive Summary (NIST SP 1800-8A), which describes the: ▪

challenges enterprises face in securing the wireless infusion pump ecosystem

▪

example solution built at the NCCoE

▪

benefits of adopting the example solution

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

Technology or security program managers concerned with how to identify, understand, assess, and mitigate risk will be interested in this part of the guide, NIST SP 1800-8b, which describes what we did and why. The following sections will be of particular interest: ▪

Section 4, Risk Assessment and Mitigation, provides a description of the risk analysis we performed

▪

Section 4.3, Security Characteristics and Controls Mapping, maps the security characteristics of this example solution to cybersecurity standards and best practices

You might share the Executive Summary, NIST SP 1800-8A, with your leadership team member to help them understand the significant risk of unsecured IoMT and the importance of adopting standardsbased, commercially available technologies that can help secure the wireless infusion pump ecosystem. IT professionals who want to implement an approach like this will find the whole practice guide useful. You can use the How-To portion of the guide, NIST SP 1800-8C, to replicate all or parts of the build created in our lab. The How-To guide provides specific product installation, configuration, and integration instructions for implementing the example solution. We do not recreate the product manufacturers’ documentation, which is generally widely available. Rather, we show how we incorporated the products together in our environment to create an example solution. This guide assumes that IT professionals have experience implementing security products within the enterprise. While we have used a suite of commercial products to address this challenge, this guide does not endorse these particular products. Your organization can adopt this solution or one that adheres to these guidelines in whole, or you can use this guide as a starting point for tailoring and implementing parts of NCCoE’s questionnaire-based risk assessment and the deployment of a defense-in-depth strategy. Your organization’s security experts should identify the products that will best integrate with your existing tools and IT system infrastructure. We hope you will seek products that are congruent with applicable standards and best practices. Section 4.4, Technologies, lists the products we used and maps them to the cybersecurity controls provided by this reference solution.

NIST SP 1800-8B: Securing Wireless Infusion Pumps

6

2.1 Typographic Conventions The following table presents typographic conventions used in this volume.

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

Typeface/Symbol

Meaning

Example

Italics

filenames and pathnames references to documents that are not hyperlinks, new terms, and placeholders

For detailed definitions of terms, see the NCCoE Glossary.

Bold

names of menus, options, command buttons and fields

Choose File > Edit.

Monospace

command-line input, on-screen computer output, sample code examples, status codes

mkdir

Monospace Bold

command-line user input contrasted with computer output

service sshd start

blue text

link to other parts of the document, a web URL, or an email address

All publications from NIST’s National Cybersecurity Center of Excellence are available at https://nccoe.nist.gov.

3 Approach Medical devices have grown increasingly powerful, offering patients improved, safer healthcare options with less physical effort for providers. To accomplish this, medical devices now contain operating systems and communication hardware that allow them to connect to networks and other devices. The connected functionality responsible for much of the improvement of medical devices poses challenges not formerly seen with standalone instruments. Clinicians and patients rely on infusion pumps for a safe and accurate administration of fluids and medications. However, the FDA has identified problems that can compromise the safe use of external infusion pumps [2], [3], [7]. These issues can lead to over-infusion or under-infusion, missed treatments, or delayed therapy. The NCCoE initiated this project to help healthcare providers develop a more secure wireless infusion pump ecosystem, which can be applied to similarly connected medical devices. The wireless infusion pump was selected as a representative medical device. Throughout the remainder of this guide, the focus will be on the secure operation of the wireless infusion pump ecosystem. Both the

NIST SP 1800-8B: Securing Wireless Infusion Pumps

7

architecture and security controls may be applied to increase the security posture for other types of medical devices. However, any application should be reviewed and tailored to the specific environment in which the medical device will operate.

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

Throughout the wireless infusion pump project, we collaborated with our healthcare Community of Interest (COI) and cybersecurity vendors to identify infusion pump threat actors, define interactions between the actors and systems, review risk factors, develop an architecture and reference design, identify applicable mitigating security technologies, and design an example implementation. This practice guide highlights the approach used to develop the NCCoE reference solution. Elements include risk assessment and analysis, logical design, build development, test and evaluation, and security control mapping. This practice guide seeks to help the healthcare community evaluate the security environment surrounding infusion pumps deployed in a clinical setting.

3.1 Audience This guide is primarily intended for professionals implementing security solutions within an HDO. It may also be of interest to anyone responsible for securing non-traditional computing devices (i.e., the Internet of Things [IoT]). More specifically, Volume B of the practice guide (NIST SP 1800-8B) is designed to appeal to a wide range of job functions. This volume provides cybersecurity or technology decision makers within HDOs with a view into how they can make the medical device environment more secure to help improve their enterprise’s security posture and help reduce enterprise risk. Additionally, this volume offers technical staff guidance on architecting a more secure medical device network and instituting compensating controls.

3.2 Scope The NCCoE project focused on securing the environment of the medical device and not re-engineering the device itself. To do this, we reviewed known vulnerabilities in wireless infusion pumps and examined how the architecture and component integration could be designed to increase the security of the device. The approach considered the life cycle of a wireless infusion pump, from planning the purchase to decommissioning, with a concentration on the configuration, use, and maintenance phases.

3.3 Assumptions Considerable research, investigation, and collaboration went into the development of the reference design in this guide. The actual build and example implementation of this architecture occurred in a lab environment at the NCCoE. Although the lab is based on a clinical environment, it does not mirror the complexity of an actual hospital network. It is assumed that any actual clinical environment would represent additional complexity.

NIST SP 1800-8B: Securing Wireless Infusion Pumps

8

3.4 Security We assume that those of you who plan to adopt this solution, or any of its components, have some degree of network security already in place. As a result, we focused primarily on new vulnerabilities that may be introduced if organizations implement the example solution. Section 4, Risk Assessment and Mitigation, contains detailed recommendations on how to secure the core components highlighted in this practice guide.

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

3.5 Existing Infrastructure This guide may help you design an entirely new infrastructure; however, this guide is geared toward those with an established infrastructure, as that represents the largest portion of readers. Hospitals and clinics are likely to have some combination of the capabilities described in this reference solution. Before applying any measures addressed in this guide, we recommend that you review and test them for applicability to your existing environment. No two hospitals or clinics are the same, and the impact of applying security controls will differ.

3.6 Technical Implementation The guide is written from a how-to perspective. Its foremost purpose is to provide details on how to install, configure, and integrate components, and how to construct correlated alerts based on the capabilities that we selected.

3.7 Capability Variation We fully understand that the capabilities presented here are not the only security options available to the healthcare industry. Desired security capabilities may vary considerably from one provider to the next.

4 Risk Assessment and Mitigation NIST Special Publication (SP) 800-30, Guide for Conducting Risk Assessments, states that risk is “a measure of the extent to which an entity is threatened by a potential circumstance or event, and typically a function of (i) the adverse impacts that would arise if the circumstance or event occurs and (ii) the likelihood of occurrence” [11]. The guide further defines risk assessment as “the process of identifying, estimating, and prioritizing risks to organizational operations (including mission, functions, image, reputation), organizational assets, individuals, other organizations, and the Nation, resulting from the operation of an information system. Part of risk management incorporates threat and vulnerability analyses, and considers mitigations provided by security controls planned or in place.” The NCCoE recommends that any discussion of risk management, particularly at the enterprise level, begins with a comprehensive review of NIST SP 800-37, Guide for Applying the Risk Management

NIST SP 1800-8B: Securing Wireless Infusion Pumps

9

Framework to Federal Information Systems—material that is available to the public [12]. The risk management framework (RMF) guidance, as a whole, proved to be invaluable in giving us a baseline to assess risks, from which we developed the project, the security characteristics of the build, and this guide. It is important to understand what constitutes the definition of risk, as it relates to non-traditional information systems, such as wireless infusion pumps. NIST SP 800-37 presents three tiers in the risk management hierarchy (Figure 4-1): This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

▪

Tier 1: Organization

▪

Tier 2: Mission/Business Process

▪

Tier 3: Information System

Figure 4-1 Tiered Risk Management Approach [12]

This guide focuses on the Tier 3 application of risk management, but incorporates other industry risk-management and risk-assessment standards and best practices for the context of networked medical devices in HDOs: ▪

American National Standards Institute (ANSI)/AAMI/IEC 80001-1:2010: Application of risk management for IT-networks incorporating medical devices – Part 1: Roles, responsibilities and activities [23]

NIST SP 1800-8B: Securing Wireless Infusion Pumps

10

▪

IEC/TR 80001-2: Application of risk management for IT-networks incorporating medical devices [15], [16], [17], [18], [19]

▪

ANSI/AAMI/International Standards Organization (ISO) 14971:2007: Medical devices – Application of risk management to medical devices [24]

▪

AAMI TIR57: 2016: Principles for medical device security – Risk management [9]

▪

FDA’s Postmarket Management of Cybersecurity in Medical Devices [3]

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

For this NCCoE project, it was extremely important to understand the complexity of networked medical devices in a system-of-systems environment. Additionally, we felt that it is necessary to understand where security risks may have safety implications. AAMI TIR57 [9] was particularly useful in this regard, as it specified elements of medical device security using NIST’s RMF, ANSI/AAMI/IEC 80001-1, IEC/TR 80001-2, and ANSI/AAMI/ISO 14971:2007 [11], [12], [13], [15], [16], [17], [18], [19], [23], [24]. Also, the Venn diagram in Figure 4-2 illustrates the relationship between security and safety risks (AAMI TIR57). As seen in this diagram, there are cybersecurity risks that may have safety impacts. For HDOs, these risks should receive special attention from both security and safety personnel. Figure 4-2 Relationship Between Security and Safety Risks [9]

4.1 Risk Assessments For this NCCoE project, we performed two types of risk assessments: an industry analysis of risk and a questionnaire-based risk assessment.

NIST SP 1800-8B: Securing Wireless Infusion Pumps

11

4.1.1 Industry Analysis of Risk The first assessment was an industry analysis of risk performed while developing the initial use case. This industry analysis provided insight into the challenges of integrating medical devices into a clinical environment containing a standard IT network. Completion of the industry analysis narrowed the objective of our use case to helping HDOs secure medical devices on an enterprise network, with a specific focus on wireless infusion pumps.

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

Activities involved in our industry analysis included reaching out to our COI and other industry experts through workshops and focus group discussions. After receiving feedback on the NCCoE’s use case publication through a period of public comment, the NCCoE adjudicated the comments and clarified a project description. These activities were instrumental to identifying primary risk factors as well as educating our team on the uniqueness of cybersecurity risks involved in protecting medical devices in healthcare environments.

4.1.2 Questionnaire-Based Risk Assessment For the second type of risk assessment, we conducted a formal questionnaire-based risk assessment by using tools from two NCCoE Cooperative Research and Development Agreement (CRADA) collaborators. We conducted this questionnaire-based risk assessment to gain a greater understanding of the risks surrounding the wireless infusion pump ecosystem. The tool identifies the risks and maps them to the security controls. This type of risk assessment is considered appropriate for Tier 3: Information System, per NIST’s RMF. One tool focuses on medical devices and the surrounding ecosystem, and the other tool focuses on the HDO enterprise. Both questionnaire-based risk assessment tools leverage guidance and best practices, including the NIST RMF and Cybersecurity Framework, and focus on built-in threats, vulnerabilities, and controls [10], [11], [12], [13]. The assessment results measure the likelihood, severity, and impact of potential threats. All risk assessment activities provide an understanding of the challenges and risks involved when integrating medical devices—in this case, wireless infusion pumps—into a typical IT network. Based on this analysis, this project has two fundamental objectives: ▪

protect the wireless infusion pumps from cyber attacks

▪

protect the healthcare ecosystem, should a wireless infusion pump be compromised

Per AAMI TIR57, “To assess security risk, several factors need to be identified and documented” [9]. Based on our risk assessments and additional research, we identified primary threats, vulnerabilities, and risks that should be addressed when using wireless infusion pumps in HDOs.

NIST SP 1800-8B: Securing Wireless Infusion Pumps

12

4.1.3 Assets Defining the asset is the first step in establishing the asset-threat-vulnerability construct necessary to properly evaluate or measure risks, per NIST’s RMF [11], [12], [13]. An information asset is typically defined as a software application or information system that uses devices or third-party vendors for support and maintenance. For the NCCoE’s purposes, the information asset selected is a wireless infusion pump system. A risk assessment of this asset would include an evaluation of the cybersecurity controls for the pump, pump server, endpoint connections, network controls, data storage, remote access, vendor support, inventory control, and any other associated elements. This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

4.1.4 Threats Some potential known threats in HDOs that use network-connected medical devices, such as wireless infusion pumps, are listed below. Refer to Appendix A for a description of each threat. ▪

targeted attacks

▪

advanced persistent threats (APTs)

▪

disruption of service: denial-of-service (DoS) and distributed-denial-of-service (DDoS) attacks

▪

malware infections

▪

theft or loss of assets

▪

unintentional misuse

▪

vulnerable systems or devices directly connected to the device (e.g., via Universal-Serial-Bus [USB] or other hardwired, non-network connections)

It is important to understand that the threat landscape is constantly evolving, and that unknown threats exist and may be unavoidable. These unknown threats need to be identified and remediated as soon as possible after they are found.

4.1.5 Vulnerabilities Vulnerabilities afflict wireless infusion pump devices, pump management applications, network applications, and even the physical environment and personnel using the device or associated systems. Within a complex system-of-systems environment, vulnerabilities may be exploited at all levels. There are multiple information resources available to keep you informed about potential vulnerabilities. This guide recommends that security professionals turn to the National Vulnerability Database (NVD). The NVD is the United States (U.S.) government repository of standards-based vulnerability management data (https://nvd.nist.gov). Some typical vulnerabilities that may arise when using wireless infusion pumps are listed below. Refer to Appendix B for a description of each vulnerability.

NIST SP 1800-8B: Securing Wireless Infusion Pumps

13

▪

lack of asset inventory

▪

long useful life

▪

information/data vulnerabilities

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

▪

▪

▪

•

lack of encryption on private/sensitive data at rest

•

lack of encryption on transmitted data

•

unauthorized changes to device calibration or configuration data

•

insufficient data backup

•

lack of capability to de-identify private/sensitive data

•

lack of data validation

device/endpoint (infusion pump) vulnerabilities •

debug-enabled interfaces

•

use of removable media

•

lack of physical tamper detection and response

•

misconfiguration

•

poorly protected and unpatched devices

user or administrator accounts vulnerabilities •

hard-coded or factory default passcodes

•

lack of role-based access and/or use of principles of least privilege

•

dormant accounts

•

weak remote access controls

IT network infrastructure vulnerabilities •

lack of malware protection

•

lack of system hardening

•

insecure network configuration

•

system complexity

To mitigate risk factors, HDOs should also strive to work closely with medical device manufacturers and to follow FDA’s postmarket guidance, as well as instructions from the U.S. Department of Homeland Security’s Industrial Control Systems Cyber Emergency Response Team (ICS-CERT).

NIST SP 1800-8B: Securing Wireless Infusion Pumps

14

4.1.6 Risks NIST SP 800-30, Guide for Conducting Risk Assessments, defines risk as, “a measure of the extent to which an entity is threatened by potential circumstance or event, and is typically a function of: (i) the adverse impacts that would arise if the circumstance or event occurs; and (ii) the likelihood of occurrence” [11].

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

NIST SP 800-30 further notes, within a definition of risk assessment, that, “assessing risk requires careful analysis of threat and vulnerability information to determine the extent to which circumstances or events could adversely impact an organization and the likelihood that such circumstances or events will occur.” Based on the above guidance from NIST SP 800-30, several risks endanger medical devices: ▪

Infusion pumps and server components may be leveraged for APTs and may serve as pivot points to cause adverse conditions throughout a hospital’s infrastructure.

▪

Infusion pumps may be manipulated to prevent the effective implementation of safety measures, such as the drug library.

▪

Infusion pump interfaces may be used for unintended or unexpected purposes, with those conditions leading to degraded performance of the pump.

▪

PHI may be accessed remotely by unauthorized individuals.

▪

PHI may be disclosed to unauthorized individuals if the device is lost, stolen, or improperly decommissioned.

▪

Hospital’s network may have improper third-party vendor connections

Although these risks may persist in infusion pumps and server components, HDOs should perform appropriate due diligence in determining the extent of the business impact and the likelihood of each risk factor. Vulnerabilities may be present in infusion pumps and their server components, as these devices often include embedded operating systems on the endpoints. Infusion pumps are designed to maintain a prolonged period of useful life, and, as such, may include system components (e.g., an embedded operating system) that may reach either their end of life, or a period of degraded updates prior to the infusion pump being retired from service. Patching and updating may become difficult over the course of time. Infusion pumps may not allow for the addition of third-party mechanisms, such as antivirus or antimalware controls. Infusion pumps are validated medical devices, with set configuration and deployment specifications, and therefore may not accept third-party security controls or third-party-provided endpoint mitigation on the pump itself. Validation supports a manufacturer’s capabilities regarding the intended purpose of the device (i.e., infusing patients with medication, analgesics, or nutrients), and

NIST SP 1800-8B: Securing Wireless Infusion Pumps

15

requirements around the validation and approval process for medical devices fall under the auspices of the FDA. If limitations are identified in embedded operating systems used by an infusion pump, then vulnerabilities, weaknesses, and deficiencies may become known to malicious actors who may seek to leverage those deficiencies to install malicious or unauthorized software on those devices.

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

Malicious software, or malware, may cause adverse conditions on the pump, degrading the performance of the pump or rendering the device unable to perform its function (e.g., ransomware; trojans that may allow for remote access to use the device as a pivot point; backdoors; malicious software that may allow for data exfiltration or may inappropriately consume system resources, preventing the pump from rendering patient care functionality). Additionally, malware may be used to convert the infusion pump into an access point for malicious actors to subsequently access or disrupt the operations of other hospital systems. As noted above, infusion pumps may allow for the manipulation of configurations or safety measures implemented through the drug library (e.g., adjusting dosage or flow rates). This risk may be instantiated through local access, such as an interface or port on the device with either no or weak authentication or access control in place. Further, infusion pumps may be reachable across a hospital’s network, which provides an avenue for a malicious actor to cause an adverse event. Pumps may implement local ports, such as USB ports serial interfaces, Bluetooth, radio frequency, or other mechanisms that allow for close proximity connection to the pump. These ports may be implemented with the intent to facilitate technical support; however, they also pose a risk by providing a pathway for malicious actors to cause adverse conditions to the pump. Modern infusion pumps and server components may include PHI, such as a patient’s name, medical record number (MRN), procedure coding, and medication or treatment. Through similar deficiencies that would allow configuration or use manipulation as noted above, this PHI may then be viewed, accessed, or removed by unauthorized individuals. Also, individuals who have direct access to the infusion pump may be able to extract information through unsecured ports or interfaces [2], [3], [7], [17], [25]. The following common vulnerabilities and control deficiencies may enable these risks: ▪

Implementation of default credentials and passwords: Weak authentication and default passwords, or not implementing authentication or access control, may be discovered by malicious actors who would seek to cause adverse conditions. Malicious actors may leverage this control deficiency for risk factors that span from installing malware on the infusion pump, to manipulating configuration settings, to extracting information, such as PHI, from the device.

▪

Use of unsecured network ports, such as Telnet or File Transfer Protocol (FTP): Telnet and FTP are internet protocols that do not secure or encrypt network sessions. Telnet and FTP may be used nominally for technical support interfaces; however, malicious actors may attempt to leverage these protocols to access the infusion pump. Telnet and FTP may include deficiencies

NIST SP 1800-8B: Securing Wireless Infusion Pumps

16

that allow for the protocol itself to be compromised, and, because the network session is not encrypted, malicious actors may implement mechanisms to capture network sessions, including any authentication traffic, or to identify sensitive information, such as credentials, configuration information, or any PHI stored on the device. ▪

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

Local interfaces with limited security controls: Local interfaces, such as USB ports, serial ports, Bluetooth, radio frequency, or other ports may be used for device technical support. These ports, however, allow for malicious actors within close proximity to the device to access the device, to manipulate configuration settings, to access or remove data from the device, or to install malware on the device. These ports may exist on the pump for support purposes; however, use of the ports for unauthorized or unexpected purposes, such as recharging a mobile device (e.g., smart phone, tablet), may cause a disruption to the pump’s standard operation.

4.1.7 Recommendations and Best Practices The recommendations provided in Appendix C address additional security concerns that, although not as pressing as those listed above, are worthy of consideration. If applied, these additional recommendations will likely reduce risk factors or prevent them from becoming greater risks. Associated best practices for reducing the overall risk posture of infusion pumps are also included in Appendix C.

4.2 Risk Response Strategy Risk mitigation is often confused with risk response. Per NIST SP 800-30, risk mitigation is defined as “prioritizing, evaluating, and implementing the appropriate risk-reducing controls/countermeasures recommended from the risk management process.” Risk mitigation is a subset of risk response. Risk response is defined by NIST SP 800-30 as accepting; avoiding; mitigating; sharing, or transferring risks. When considering risk response, your organization should recommend, to a corporate risk management board, ways that the Information Risk Manager (or equivalent) should treat risk.

4.2.1 Risk Mitigation Organizations must determine their tolerance or appetite for risk—the response to which will drive risk remediation or risk mitigation for identified risks. This tolerance should be codified in a Risk Management Plan, which will include regulatory requirements and guidance, industry best practices, and security controls. Organizations should set an appropriate risk tolerance based on the factors noted above, with the intent to remediate those risks above the established risk tolerance (i.e., critical or high risks.) These remediation responses can take the form of administrative, physical, and technical controls, or an appropriate mix. As previously mentioned, Appendix C identifies several mitigation recommendations

NIST SP 1800-8B: Securing Wireless Infusion Pumps

17

regarding specific risk. Additional compensating safeguards, countermeasures, or controls are noted below:

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

▪

physical security controls, including standard tamper-evident physical seals, which can be applied to hardware to indicate unauthorized physical access [10], [14]

▪

ensuring the implementation of a physical asset management program that manages and tracks unique, mobile media, such as removable flash memory devices (e.g., Secure Digital [SD] cards, thumb drives) used by pump software hosted on an endpoint client. Consider the encryption of all portable media used in such a fashion [10], [14], [26], [27].

▪

following procedures for clearing wireless network authentication credentials on the endpoint client if the pump is to be removed or transported from the facility. These procedures can be found in pump user manuals, but should be referenced in official HDO policies and procedures [28], [29], [30], [31].

▪

changing wireless network authentication credentials regularly and, if there is evidence of unauthorized access to a pump system, immediately changing network authentication credentials [10], [14]

▪

ensuring that all wireless network access is minimally configured for Wi-Fi Protected Access II (WPA2) Pre-Shared Key (PSK) encryption and authentication. All pumps should be set to WPA2 encryption [32], [33], [34], [35].

▪

ensuring that all patching has been applied, including those components that will use WPA2

▪

All pumps and pump systems should include cryptographic modules that have been validated as meeting NIST Federal Information Processing Standards (FIPS) Publication 140-2 [36].

▪

All ports are disabled, except when in use, and the device has no listening ports [3], [9], [10], [14], [25].

▪

employing mutual transport layer security (TLS) encryption in transit between the client and server [37]

▪

employing individual pump authentication with no shared key for all pumps [10], [14]

▪

certificate-based authentication for a pump server [28], [29], [30], [31]

During the course of this project, several vulnerabilities were published in the NVD (https://nvd.nist.gov) that identified means by which malicious actors may remotely compromise WPA2-secured sessions through the use of “key reinstallation attacks” (KRACKs). Individuals should review noted WPA2 vulnerabilities, refer to vendor/manufacturer patching and updates, and apply those patches and updates as soon as possible.

4.3 Security Characteristics and Controls Mapping As described in the previous sections, we derived the security characteristics by analyzing risk in collaboration with our healthcare-sector stakeholders as well as our participating vendor partners. In

NIST SP 1800-8B: Securing Wireless Infusion Pumps

18

the risk analysis process, we used IEC/TR 80001-2-2 as our basis for wireless infusion pump capabilities in healthcare environments [16]. Table 4-1 presents the desired security characteristics of the use case, in terms of the NIST Cybersecurity Framework Subcategories [10], [14]. Each subcategory is mapped to relevant NIST standards, industry standards, controls, and best practices. In our example implementation, we did not observe any security characteristics that mapped to the Respond or Recover Subcategories of the NIST Cybersecurity Framework.

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8. NIST SP 1800-8B: Securing Wireless Infusion Pumps

19

Table 4-1 Security Characteristics and Controls Mapping –- NIST Cyber Security Framework NIST Cybersecurity Framework v1.1 Function

Category

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

Asset Management (ID.AM) IDENTIFY (ID)

Business Environment (ID.BE)

Sector-Specific Standards & Best Practices NIST SP 800-53 Revision 4

IEC/TR 80001-2-2

HIPAA Security Rule [38]

ISO/IEC 27001:2013 [39]

ID.AM-1: Physical devices and systems within the CM-8 organization are inventoried

CNFS

45 C.F.R. §§ 164.308(a)(1)(ii)(A), 164.310(a)(2)(ii), 164.310(d)

A.8.1.1, A.8.1.2

ID.AM-5: Resources (e.g., hardware, devices, data, time, and software) are prioritized based on their classification, criticality, and business value

DTBK

45 C.F.R. §§ 164.308(a)(7)(ii)(E)

A.8.2.1

DTBK

45 C.F.R. §§ 164.308(a)(7)(i), 164.308(a)(7)(ii)(E), 164.310(a)(2)(i), 164.312(a)(2)(ii), 164.314(a)(1), 164.314(b)(2)(i)

A.11.2.2, A.11.2.3, A.12.1.3

Subcategory

ID.BE-4: Dependencies and critical functions for delivery of critical services are established

NIST SP 1800-8B: Securing Wireless Infusion Pumps

CP-2, RA-2, SA-14, SC-6

CP-8, PE-9, PE-11, PM-8, SA-14

20

NIST Cybersecurity Framework v1.1 Function

Category

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

Risk Assessment (ID.RA)

PROTECT (PR)

Identity Management and Access Control (PR.AC)

Sector-Specific Standards & Best Practices

Subcategory

NIST SP 800-53 Revision 4

IEC/TR 80001-2-2

HIPAA Security Rule [38]

ISO/IEC 27001:2013 [39]

ID.RA-1: Asset vulnerabilities are identified and documented

CA-2, CA-7, CA-8, RA-3, RA-5, SA-5, SA-11, SI-2, SI-4, SI-5

RDMP

45 C.F.R. §§ 164.308(a)(1)(ii)(A), 164.308(a)(7)(ii)(E), 164.308(a)(8), 164.310(a)(1), 164.312(a)(1), 164.316(b)(2)(iii)

A.12.6.1, A.18.2.3

(Note: not directly mapped in the NIST Cybersecurity Framework)

AC-1, AC-11, AC-12

ALOF

None

None

AUTH, CNFS, EMRG, PAUT

45 C.F.R. §§ 164.308(a)(3)(ii)(B), 164.308(a)(3)(ii)(C), 164.308(a)(4)(i), 164.308(a)(4)(ii)(B), 164.308(a)(4)(ii)(C), 164.312(a)(2)(i), 164.312(a)(2)(ii), 164.312(a)(2)(iii), 164.312(d)

A.9.2.1, A.9.2.2, A.9.2.4, A.9.3.1, A.9.4.2, A.9.4.3

PR.AC-1: Identities and credentials are issued, managed, verified, revoked, and audited for authorized devices, users and processes

NIST SP 1800-8B: Securing Wireless Infusion Pumps

AC-1, AC-2, IA-1, IA-2, IA-3, IA-4, IA-5, IA-6, IA-7, IA-8, IA-9, IA-10, IA-11

21

NIST Cybersecurity Framework v1.1 Function

Category

Subcategory

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

PR.AC-2: Physical access to assets is managed and protected

PR.AC-3: Remote access is managed

NIST SP 1800-8B: Securing Wireless Infusion Pumps

Sector-Specific Standards & Best Practices NIST SP 800-53 Revision 4

PE-2, PE-3, PE-4, PE-5, PE-6, PE-9

C-1, AC-17, AC-19, AC20, SC-15

IEC/TR 80001-2-2

HIPAA Security Rule [38]

ISO/IEC 27001:2013 [39]

PLOK, TXCF, TXIG

45 C.F.R. §§ 164.308(a)(1)(ii)(B), 164.308(a)(7)(i), 164.308(a)(7)(ii)(A), 164.310(a)(1), 164.310(a)(2)(i), 164.310(a)(2)(ii), 164.310(a)(2)(iii), 164.310(b), 164.310(c), 164.310(d)(1), 164.310(d)(2)(iii)

A.11.1.1, A.11.1.2, A.11.1.4, A.11.1.6, A.11.2.3

NAUT, PAUT

45 C.F.R. §§ 164.308(a)(4)(i), 164.308(b)(1), 164.308(b)(3), 164.310(b), 164.312(e)(1), 164.312(e)(2)(ii)

A.6.2.2, A.13.1.1, A.13.2.1

22

NIST Cybersecurity Framework v1.1 Function

Category

Subcategory

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

PR.AC-4: Access permissions and authorizations are managed, incorporating the principles of least privilege and separation of duties

PR.AC-5: Network integrity is protected (e.g., network segregation, network segmentation)

NIST SP 1800-8B: Securing Wireless Infusion Pumps

Sector-Specific Standards & Best Practices NIST SP 800-53 Revision 4

AC-1, AC-2, AC-3, AC-5, AC-6, AC14, AC-16, AC-24

AC-4, AC10, SC-7

IEC/TR 80001-2-2

HIPAA Security Rule [38]

ISO/IEC 27001:2013 [39]

AUTH, CNFS, EMRG, NAUT, PAUT

45 C.F.R. §§ 164.308(a)(3), 164.308(a)(4), 164.310(a)(2)(iii), 164.310(b), 164.312(a)(1), 164.312(a)(2)(i), 164.312(a)(2)(ii)

A.6.1.2, A.9.1.2, A.9.2.3, A.9.4.1, A.9.4.4

NAUT

45 C.F.R. §§ 164.308(a)(4)(ii)(B), 164.310(a)(1), 164.310(b), 164.312(a)(1), 164.312(b), 164.312(c), 164.312(e)

A.13.1.1, A.13.1.3, A.13.2.1

23

NIST Cybersecurity Framework v1.1 Function

Category

Subcategory

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

PR.DS-1: Data-at-rest is protected

Sector-Specific Standards & Best Practices NIST SP 800-53 Revision 4

MP-8, SC12, SC-28

IEC/TR 80001-2-2

HIPAA Security Rule [38]

IGAU, STCF

45 C.F.R. §§ 164.308(a)(1)(ii)(D), 164.308(b)(1), 164.310(d), 164.312(a)(1), A.8.2.3 164.312(a)(2)(iii), 164.312(a)(2)(iv), 164.312(b), 164.312(c), 164.314(b)(2)(i), 164.312(d)

IGAU, TXCF

45 C.F.R. §§ 164.308(b)(1), 164.308(b)(2), 164.312(e)(1), 164.312(e)(2)(i), 164.312(e)(2)(ii), 164.314(b)(2)(i)

Data Security (PR.DS)

PR.DS-2: Data-in-transit is protected

NIST SP 1800-8B: Securing Wireless Infusion Pumps

SC-8, SC-11, SC-12

ISO/IEC 27001:2013 [39]

A.8.2.3, A.13.1.1, A.13.2.1, A.13.2.3, A.14.1.2, A.14.1.3

24

NIST Cybersecurity Framework v1.1 Function

Category

Subcategory

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

PR.DS-4: Adequate capacity to ensure availability is maintained

Information Protection Processes and Procedures (PR.IP)

Sector-Specific Standards & Best Practices NIST SP 800-53 Revision 4

AU-4, CP-2, SC-5

PR.DS-6: Integrity checking mechanisms are used to verify software, firmware, and information integrity

SC-16, SI-7

PR.IP-1: A baseline configuration of information technology/industrial control systems is created and maintained incorporating security principles (e.g. concept of least functionality)

CM-2, CM-3, CM-4, CM-5, CM-6, CM-7, CM-9, SA-10

NIST SP 1800-8B: Securing Wireless Infusion Pumps

IEC/TR 80001-2-2

HIPAA Security Rule [38]

ISO/IEC 27001:2013 [39]

AUDT, DTBK

45 C.F.R. §§ 164.308(a)(1)(ii)(A), 164.308(a)(1)(ii)(B), 164.308(a)(7), 164.310(a)(2)(i), 164.310(d)(2)(iv), 164.312(a)(2)(ii)

A.12.3.1

IGAU

45 C.F.R. §§ 164.308(a)(1)(ii)(D), 164.312(b), 164.312(c)(1), 164.312(c)(2), 164.312(e)(2)(i)

A.12.2.1, A.12.5.1, A.14.1.2, A.14.1.3

45 C.F.R. §§ 164.308(a)(8), 164.308(a)(7)(i), 164.308(a)(7)(ii)

A.12.1.2, A.12.5.1, A.12.6.2, A.14.2.2, A.14.2.3, A.14.2.4

CNFS, CSUP, SAHD, RDMP

25

NIST Cybersecurity Framework v1.1 Function

Category

Subcategory

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

PR.IP-4: Backups of information are conducted, maintained, and tested

PR.IP-6: Data is destroyed according to policy

PR.MA-2: Remote maintenance of organizational assets is approved, logged, and performed in a manner that prevents unauthorized access

NIST SP 1800-8B: Securing Wireless Infusion Pumps

Sector-Specific Standards & Best Practices NIST SP 800-53 Revision 4

CP-4, CP-6, CP-9

MP-6

MA-4

IEC/TR 80001-2-2

HIPAA Security Rule [38]

ISO/IEC 27001:2013 [39]

DTBK

45 C.F.R. §§ 164.308(a)(7)(ii)(A), 164.308(a)(7)(ii)(B), 164.308(a)(7)(ii)(D), 164.310(a)(2)(i), 164.310(d)(2)(iv)

A.12.3.1, A.17.1.2, A.17.1.3, A.18.1.3

DIDT

45 C.F.R. §§ 164.310(d)(2)(i), 164.310(d)(2)(ii)

A.8.2.3, A.8.3.1, A.8.3.2, A.11.2.7

CSUP

45 C.F.R. §§ 164.308(a)(3)(ii)(A), 164.310(d)(1), 164.310(d)(2)(ii), 164.310(d)(2)(iii), 164.312(a), 164.312(a)(2)(ii), 164.312(a)(2)(iv), 164.312(b), 164.312(d), 164.312(e), 164.308(a)(1)(ii)(D)

A.11.2.4, A.15.1.1, A.15.2.1

26

NIST Cybersecurity Framework v1.1 Function

Sector-Specific Standards & Best Practices

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

Category

Subcategory

NIST SP 800-53 Revision 4

Anomalies and Events (DE.AE)

DE.AE-1: A baseline of network operations and expected data flows for users and systems is established and managed

AC-4, CA-3, CM-2, SI-4

DE.CM-1: The network is monitored to detect potential cybersecurity events

AC-2, AU-12, CA-7, CM-3, SC-5, SC-7, SI-4

IEC/TR 80001-2-2

HIPAA Security Rule [38]

AUTH, CNFS

45 C.F.R. §§ 164.308(a)(1)(ii)(D), None 164.312(b)

AUTH, CNFS, EMRG, MLDP

45 C.F.R. §§ 164.308(a)(1)(ii)(D), 164.308(a)(5)(ii)(B), 164.308(a)(5)(ii)(C), None 164.308(a)(8), 164.312(b), 164.312(e)(2)(i)

DE.CM-3: Personnel activity is monitored to detect potential cybersecurity events

AC-2, AU-12, AU-13, CA-7, CM-10, CM-11

AUTH, CNFS, EMRG, MLDP

45 C.F.R. §§ 164.308(a)(1)(ii)(D), 164.308(a)(3)(ii)(A), 164.308(a)(5)(ii)(C), A.12.4.1 164.312(a)(2)(i), 164.312(b), 164.312(d), 164.312(e)

DE.CM-4: Malicious code is detected

SI-3, SI-8

IGAU, MLDP, TXIG

45 C.F.R. §§ 164.308(a)(1)(ii)(D), A.12.2.1 164.308(a)(5)(ii)(B)

DETECT (DE) Security Continuous Monitoring (DE.CM)

NIST SP 1800-8B: Securing Wireless Infusion Pumps

ISO/IEC 27001:2013 [39]

27

NIST Cybersecurity Framework v1.1

Sector-Specific Standards & Best Practices

Subcategory

NIST SP 800-53 Revision 4

IEC/TR 80001-2-2

HIPAA Security Rule [38]

ISO/IEC 27001:2013 [39]

DE.CM-6: External service provider activity is monitored to detect potential cybersecurity events

CA-7, PS-7, SA-4, SA-9, SI-4

RDMP

45 C.F.R. §§ 164.308(a)(1)(ii)(D)

A.14.2.7, A.15.2.1

Detection Processes (DE.DP)

DE.DP-3: Detection processes are tested

CA-2, CA-7, PE-3, PM-14, SI3, SI-4

IGAU

45 C.F.R. §§ 164.306(e)

A.14.2.8

RESPOND (RS)

None

None

None

None

None

None

RECOVER (RC)

None

None

None

None

None

None

Function

Category

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

4.4 Technologies Table 4-2 lists all of the technologies used in this project, and maps the generic application term to the specific product that we used and the security control(s) that we deployed. Refer to Table 4-1 for an explanation of the NIST Cybersecurity Framework Subcategory codes [10]. The reference architecture design in Section 5 is vendor-agnostic, such that any wireless infusion pump system can be integrated safely and securely into a hospital’s IT infrastructure. Therefore, for the infusion pump device, infusion pump server, and wireless infusion pump ecosystem, we captured the most-common security features among all the products that we tested in this use case. A normalized view of the list of Functions and NIST Cybersecurity Framework Subcategories are presented in Table 4-2.

NIST SP 1800-8B: Securing Wireless Infusion Pumps

28

Please note that some of the NIST Cybersecurity Framework Subcategory codes require people, and process controls, not solely technical controls. Table 4-2 Products and Technologies

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

Component

Specific Product

Function

NIST Cybersecurity Framework Subcategory

Infusion Pump Device

Baxter: Sigma Spectrum™ LVP Version 8

• requires a passcode to access the biomedical engineering mode (on device or connect to device) for configuring and setting up the devices

PR.AC-1, PR.AC-2, PR.DS-2, PR.DS-6, PR.IP-1, PR.IP-6

Baxter: Sigma Spectrum Wireless Battery Module Version 8

• provides the capability to change the manufacture default passcode

B. Braun: Space Infusomat Infusion Pump (LVP) BD: Alaris® 8015 Patient Care Unit (PCU) Version 9.19.2 BD: Alaris Syringe Module 8110 BD: Alaris LVP Module 8100 Hospira: Plum 360™ Version 15.10

NIST SP 1800-8B: Securing Wireless Infusion Pumps

• supports Institute of Electrical and Electronics Engineers (IEEE) 802.11i enterprise wireless encryption/authentication standards, including WPA2 with Extensible Authentication Protocol (EAP)-TLS for protecting data exchange • restricted access to the server, application, and stored data • closes/disables all communication ports that are not required for the intended use • closes/disables all services that are not required for the intended use • provides an integrity-checking mechanism to verify information • supports the baseline configuration • supports removing/destroying data from the device

29

Component

Specific Product

Function

Hospira: LifeCare PCA™ Version 7.02

• few models have a tamper-resist switch, with tamper-evident seals

NIST Cybersecurity Framework Subcategory

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

Smiths Medical: Medfusion® 3500 Version 5 Syringe Infusion System Smiths Medical: Medfusion 4000 Wireless Syringe Infusion Pump Smiths Medical: CADD®-Solis Ambulatory Infusion Pump Infusion Pump Server

Baxter: Care Everywhere Gateway Server Version 14 B. Braun: Space OnlineSuite Software Version Application Package 2.0.1 BD: Alaris Systems Manager Version 4.2

NIST SP 1800-8B: Securing Wireless Infusion Pumps

• with appropriate configuration, discovers and identifies devices connected to the pump server via wired networks, wireless networks, and virtual private networks (VPNs), to aid in building and maintaining accurate physical device inventories

ID.AM-1, PR.AC-1, PR.AC-3, PR.AC-4, PR.DS-1, PR.DS-2, PR.MA-2

• supports role-based authentication and password rules and policies • supports the use of an HDO’s Active Directory / Lightweight Directory Access Protocol (LDAP) solution

30

Component

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

Infusion Pump Ecosystem

Specific Product

Function

Hospira: MedNet™ 6.2

• supports auto-logoff, data encryption/obscuration

Smiths Medical: PharmGuard® Server Enterprise Edition Version 1.1

• can be accessed remotely via VPN (or similar) tools

Baxter: Sigma Spectrum Master Drug Library Version 8

• supports secure protocols, such as TLS

B. Braun: Space DoseTrac® and Space DoseLink™ software – Engineering version available for testing

• maintains different types of audit/log records for preventing unauthorized access

NIST Cybersecurity Framework Subcategory

• few models support FIPS Publication 140-2 • operates on a manufacturer-supported operating system, database server, and web server (allows software patches) • supports co-existence with firewall, antivirus, backup software, and other types of security safeguard products

BD: Alaris System Maintenance (ASM) Version 10.19 Smiths Medical: PharmGuard Toolbox Version 1.5 Smiths Medical: CADDSolis Medication Safety Software

NIST SP 1800-8B: Securing Wireless Infusion Pumps

31

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

Component

Specific Product

Function

Access Point (AP)

Cisco: Aironet 1600 Series AP (AIRCAP1602I-A-K9

• authenticates and connects infusion pumps to the Wi-Fi

Cisco: WLC 8.2.111.0

• AP joins a WLC to form a Control and Provisioning of Wireless Access Points protocol (CAPWAP) tunnel

Wireless LAN [Local Area Network] Controller (WLC)

• supports wireless network standards: IEEE 802.11a/b/g/n/ac • supports security protocols: IEEE 802.11i (WPA2), EAP-TLS

NIST Cybersecurity Framework Subcategory PR.AC-5, PR.DS-1, PR.DS-2, DE.CM-1, DE.CM-3

• uses Identity Services Engine (ISE) as the authentication service • provides message authentication and encryption in data transmission

Identity Services Engine (ISE)

Cisco: ISE

• discovers and identifies devices connected to wired networks, wireless networks, and VPNs. It gathers this information based on what’s actually connecting to the network, a key step toward building and maintaining accurate physical device inventories

ID.AM-1, PR.AC-1, PR.AC-4, PR.DS-1, PR.DS-2, DE.CM-1, DE.CM-3

• provides advanced network access controls by connecting user identity with device profiling and access policy • provides a log audit of events, which can be monitored for the network traffic Firewall/Router

Cisco: Adaptive Security Appliance (ASA)

• delivers network integrity protection • is used as an external firewall for connecting to the internet for guest network

PR.AC-5, PR.DS-1, PR.DS-2, DE.CM-1, DE.CM-3

• is used as internal firewall for all other network zones with rules and policies

NIST SP 1800-8B: Securing Wireless Infusion Pumps

32

NIST Cybersecurity Framework Subcategory

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

Component

Specific Product

Function

Switch

Cisco: Catalyst 3650 Switch

• provides port-level controls, port blocking, and virtual local area network (VLAN) segmentation

PR.AC-5, PR.DS-1, PR.DS-2, DE.CM-1, DE.CM-3

Endpoint Protection

Symantec: Symantec Endpoint Protection (SEP)

• provides intrusion prevention, uniform resource locator (URL), and firewall policies

DE.CM-1, DE.CM-3, DE.CM-4, PR.DS-1, PR.DS-2, DE.AE-1

• provides application behavioral controls • provides device control to restrict access • provides antivirus file protection • provides behavioral monitoring • provides file reputation analysis

Network Advanced Threat Protection

Symantec: Advanced Threat Protection: Network (ATP:N)

• monitors internal inbound and outbound internet traffic • uncovers advanced attacks • automatically prioritizes critical events

DE.CM-1, DE.CM-4, PR.DS-1, PR.DS-2, DE.AE-1

• searches for known indicators of compromise (IoCs) across the entire environment • blacklists or whitelists files and URLs once they are identified as malicious • can be integrated with a third-party security information and events management (SIEM) tool

NIST SP 1800-8B: Securing Wireless Infusion Pumps

33

Component

Specific Product

Function

Data Center Security

Symantec: Data Center Security: Server Advanced (DCS:SA)

• out-of-the-box host intrusion detection system (HIDS) and host intrusion prevention system (HIPS) policies • provides sandboxing and Process Access Control (PAC) to prevent a new class of threats

NIST Cybersecurity Framework Subcategory DE.CM-1, DE.CM-4, PR.DS-1, PR.DS-2, DE.AE-1

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

• hosts firewall to control inbound and outbound network traffic to and from servers • compensating HIPS controls restrict application and operating system behavior by using policy-based least-privilege access control • prevents file and system tampering • provides application and device control by locking down “configuration” settings, file systems, and the use of removable media Secure Remote Management and Monitoring

TDi Technologies: ConsoleWorks®

• authenticates system managers • provides role-based access control of system management functions • implements a protocol break between the system manager and the managed assets

PR.AC-3, PR.AC-4, PR.MA-2, PR.PT-1, PR.PT-3, DE.CM-1, DE.CM-3, DE.CM-4, DE.CM-6

• records all system management actions • performs remote configuration management and monitoring of devices

NIST SP 1800-8B: Securing Wireless Infusion Pumps

34

Component

Specific Product

Function

NIST Cybersecurity Framework Subcategory

Physics-Based Integrity Assessment

PFP: pMon 751 and P2Scan

• baselines the device execution behavior

DE.AE-1, DE.CM-4

• detects cyber attacks in hardware and software

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

• detects tiny anomalies in analog side-channel patterns (e.g., power consumption, electromagnetic emissions) to instantly catch attacks, thereby providing an early warning that a device has been tampered with • integrity assessment uses side channel

Certificate Authority Service

DigiCert: Certificate Authority

• provides a certificate authority service

Access Control (PR.AC) PR.DS-2

Certificate Management / Provisioning

Intercede: MyID®

• serves as a device provisioner

ID.AM-1, ID.AM-5

Risk Assessment

Clearwater: IRM|Pro™ IRM|Analysis™

• provides a tool for conducting risk assessments that focus on healthcare compliance and cyber risk management

ID.RA-1

Medical Device Innovation, Safety & Security Consortium (MDISS): Medical Device Risk Assessment Platform (MDRAP™)

• provides a tool for conducting risk assessments that focus on medical devices

NIST SP 1800-8B: Securing Wireless Infusion Pumps

35

5 Architecture Wireless infusion pumps are no longer standalone devices; they now include pump servers for managing the pumps, drug libraries, networks allowing for interoperability with other hospital systems, and VPN tunnels to outside organizations for maintenance. While interconnectivity, enhanced communications, and safety measures on the pump have added complexity to infusion pumps, these components can help improve patient outcomes and safety. This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

As infusion pumps have evolved, one safety mechanism development was the invention of the “drug library.” The drug library is a mechanism that is applied to an infusion pump and that catalogs medications, fluids, dosage, and flow rates. While hospital pharmacists may be involved in the maintenance of the drug library, continuous application of the drug library to the infusion pump environment tends to be managed through a team of biomedical engineers. Initially, the drug library file may be loaded onto the pump through a communication port. When the drug library file is updated, all infusion pumps need to be updated to ensure that they adhere to the current rendition of that drug library. Drug library distribution, which may require that staff manually adjust individual pumps, may become onerous for the biomedical staff in HDOs that use thousands of pumps [1], [40]. Manufacturers provide wireless communications on some pumps, and use a pump server to manage the drug library file, capture usage information on the pumps, and provide pump updates. Medical device manufacturers are subject to regulatory practices by the FDA, and may tend to focus on the primary function of the pump (i.e., assurance that the pump delivers fluids of a certain volume and defined flow rates, consistent with needs that providers may have to ensure safe and appropriate patient care). Technology considerations, such as cybersecurity controls, may not be primarily addressed in the device design and approval process. As such, infusion pumps may include technology that does not lend itself to the same controls that an HDO may implement on standard desktops, laptops, or workstations used for productivity [9], [18]. As technology has evolved, cybersecurity risk has expanded, both in visibility and in the number of threats and vulnerabilities. This expansion has led to a heightened concern, from manufacturers and the FDA, and work has been established to identify measures to better respond to cybersecurity risk [7], [9], [25]. In Section 5.1, we describe the wireless infusion pump ecosystem by defining the components. Section 5.2 discusses the data flow, and Section 5.3 explains the set of controls that we use in our example implementation, including those for networks, pumps, pump servers, and enterprise. Section 5.4 describes the target architecture for our example implementation.

NIST SP 1800-8B: Securing Wireless Infusion Pumps

36

5.1 Basic System A basic wireless infusion pump ecosystem includes a wireless infusion pump, a pump server, a network consisting of an AP, a firewall, and a VPN to a manufacturer (Figure 5-1). Figure 5-1 Basic System

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

5.2 Data Flow The flow of data between a wireless infusion pump and its corresponding server falls into the following transaction categories: ▪

modifying the drug library

▪

performing software updates

▪

remotely managing the devices

▪

auditing the data flow processes

Infusion pumps may also include other advanced features, such as auto-programming to receive patient prescription information and to record patient treatment information to the patient’s EHR.

NIST SP 1800-8B: Securing Wireless Infusion Pumps

37

5.3 Cybersecurity Controls This section discusses security controls by their location, either on the network, pump, or pump server. We also describe controls implemented in the NCCoE lab, and depict the controls implemented in our final architecture.

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

In general, we recommend that a clinically focused network be designed to protect the information used in HDOs, whether that information is at-rest or in-transit. As described in Cisco Medical-Grade Network (MGN) 2.0-Security Architectures, no single architecture can be designed to meet the security requirements of all organizations [41]. However, many cybersecurity best practices can be applied by HDOs to meet regulatory compliance standards. Our reference architecture uses Cisco’s solution architecture as the baseline. This baseline demonstrates how the network can be used to provide multi-tiered protection for medical devices when exchanging information via a network connection. The goal of our reference architecture is to provide countermeasures to deal with challenges identified in the assessment process. For our use-case solution, we use segmentation and defense-in-depth as security models to build and maintain a secure device infrastructure. This section provides additional details on how to employ security strategies to achieve specific targeted protections when securing wireless infusion pumps. We used the following cybersecurity controls: ▪

network controls

▪

pump controls

▪

pump server controls

▪

enterprise-level controls

5.3.1 Network Controls Proper network segmentation or network zoning is essential to developing a strong cybersecurity posture [32], [33], [34], [35], [42]. Segmentation uses network devices, such as switches and firewalls, to split a large computer network into subnetworks, each referred to as a network segment [41]. Network segmentation not only enhances network management, but also improves cybersecurity, allowing for the separation of networks based on network security requirements driven by business needs or asset value.

NIST SP 1800-8B: Securing Wireless Infusion Pumps

38

The architecture designed for this build uses Cisco’s solution architecture as the baseline for demonstrating how the network can be used to provide multi-tiered protection for medical devices when exchanging information with the outside world during the operation involving network communication. The goal of this architecture design is to provide countermeasures to mitigate challenge areas identified in the assessment process. In our use-case solution, segmentation and defense-in-depth are the security models that we used as security measures to build and maintain secure device infrastructure. This section provides additional details on how to employ security strategies to achieve the target security characteristics for securing wireless infusion pumps. This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

5.3.1.1

Segmentation/Zoning

Our network architecture uses a zone-based security approach. By using different local networks for designated purposes, networked equipment identified for a specific purpose can be put together on the same network segment and protected with an internal firewall. The implication is that there is no inherent trust between network zones and that trust limitations are enforced by properly configuring firewalls to protect equipment in one zone from other, less-trusted zones. By limiting access from other, less-trusted areas, firewalls can more effectively protect the enterprise network. For discussion purposes, we include some generic components of a typical HDO in our network architecture examples. A given healthcare facility may be simpler or more complex and may contain different subcomponents. The generic architecture contains several functional segments, including the following elements: ▪

core network

▪

guest network

▪

business office

▪

database server

▪

enterprise services

▪

clinical services

▪

biomedical engineering

▪

medical devices with wireless LAN

▪

remote access for external vendor support

At a high level, each zone is implemented as a VLAN with a combination firewall/router Cisco ASA device connecting it to the rest of the enterprise through a backbone network, referred to as the core network [43], [44], [45]. Segments may consist of physical or virtual networks. For simplicity and convenience, we implemented subnets that correspond exactly to VLANs. The routing configuration is the same for each subnet, but the firewall configuration may vary depending on each zone’s specific purpose. An external router/firewall device is used to connect the enterprise and guest network to the internet.

NIST SP 1800-8B: Securing Wireless Infusion Pumps

39

Segmentation is implemented via a VLAN by using Cisco switches. The following subsections provide a short description of each segment and the final network architecture.

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

5.3.1.1.1 Core Network Zone Our reference architecture implements a core network zone that consists of the equipment and systems used to establish the backbone network infrastructure. The external firewall/router also has an interface connected to the core enterprise network, just like other firewall/router devices in the other zones. This zone serves as the backbone of the enterprise network and consists only of routers connected by switches. The routers automatically share internal route information with each other via authenticated Open Shortest Path First (OSPF) to mitigate configuration errors as zones are added or removed. 5.3.1.1.2 Guest Network Zone Hospitals often implement a guest network that allows visitors or patients to access internet services during their visit. As shown in Figure 5-2 (Section 5.3.1.1.10), network traffic here tends not to be clinical in nature, but is offered as a courtesy to hospital visitors and patients to access the internet. Refer to Section 5.3.1.5, External Access, for additional technical details. 5.3.1.1.3 Business Office Zone A business office zone is established for systems dedicated to hospital office productivity and does not include direct patient-facing systems. This zone consists of traditional clients on an enterprise network, such as workstations, laptops, and possibly mobile devices. Within the enterprise, the business office zone will primarily interact with the enterprise services zone. This zone may also include Wi-Fi access. 5.3.1.1.4 Database Server Zone A database server zone is established to house server components that support data persistence. The database server zone may include data stores that aggregate potentially sensitive information, and, given the volume, require safeguards. Because databases may include PHI, HIPAA privacy and security controls are applicable. This zone consists of servers with databases. Ideally, applications in the enterprise services zone and biomedical engineering zone use these databases, instead of storing information on application servers. This type of centralization allows for a simplified management of security controls to protect the information stored in databases. 5.3.1.1.5 Enterprise Services Zone The enterprise services zone consists of systems that support hospital staff productivity. Enterprise services may not be directly patient-specific systems, but rather support core office functions found in a hospital. This zone consists of traditional enterprise services, such as the domain name system (DNS), Active Directory, Identity Service System, and asset inventory that probably lives in a server room or data center. These services must be accessible from various other zones in the enterprise.

NIST SP 1800-8B: Securing Wireless Infusion Pumps

40

5.3.1.1.6 Clinical Services Zone The clinical services zone consists of systems that pertain to providing patient care. Examples of systems that would be hosted in this zone include the EHR system, pharmacy systems, health information systems, and other clinical systems to support patient care.

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

5.3.1.1.7 Biomedical Engineering Zone The biomedical engineering zone establishes a separate area that enables a biomedical engineering team to manage and maintain systems, such as medical devices, as shown in Figure 5-2 (Section 5.3.1.1.10). This zone consists of all equipment needed to provision and maintain medical devices. In the case of wireless infusion pumps, this is where the pump management servers are hosted on the network. 5.3.1.1.8 Medical Device Zone The medical device zone provides a network space where medical devices may be hosted. Infusion pumps would be deployed in this zone. Infusion pump systems are designed so that all external connections to EHR systems or vendor maintenance operations can be completed through an associated pump server that resides in the biomedical engineering zone. Access to the rest of the network and internet is blocked. This zone contains a dedicated wireless network to support the wireless infusion pumps, as explained in Section 5.3.1.2, Medical Device Zone’s Wireless LAN. 5.3.1.1.9 Remote Access Zone The remote access zone provides a network segment that extends external privileged access so that vendors may access their manufactured components and systems on the broader HDO network. Refer to Section 5.3.1.4, Remote Access, for additional technical details. 5.3.1.1.10 Final Network Architecture Figure 5-2 shows the interconnection of all components and zones previously described. It also illustrates the connection to vendor and cloud services via the internet. The VLAN numbers that are shown in Figure 5-2 are the VLAN identifiers used in the lab; however, these numbers may vary on actual healthcare enterprise networks.

NIST SP 1800-8B: Securing Wireless Infusion Pumps

41

Figure 5-2 Network Architecture with Segmentation

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

5.3.1.2

Medical Device Zone’s Wireless LAN

The Wi-Fi management network is different, in that it does not have a firewall/router that connects directly to the core network, as shown in Figure 5-3. This is a completely closed network used for the management and communication between the Cisco Aironet wireless AP and the Cisco WLC. The WLC is the central point where wireless Service Set Identifiers (SSIDs), VLANs, and WPA2 security settings are managed for the entire enterprise [8], [17], [32], [33], [34], [35], [42], [46], [47], [48]. Two SSIDs were defined: IP_Dev and IP_Dev Cert. IP_Dev uses WPA2-PSK, and IP_Dev Cert uses WPA2Enterprise protocols. In an actual HDO, two WLCs should be configured for redundancy. Initially, the wireless APs configure themselves for network connectivity, like any other device using Dynamic Host Configuration Protocol (DHCP) from the switch DHCP server (see the green line in Figure 5-3). The switch also sends DHCP Option 43, which provides the Internet Protocol (IP) address of the WLC. The AP then connects to the WLC to automatically download firmware updates and wireless configuration information. Finally, the CAPWAP tunnel is formed to encrypt wireless traffic (see the black line in Figure 5-3). The traffic is then routed to the enterprise network via the WLC [27], [36], [44], [49].

NIST SP 1800-8B: Securing Wireless Infusion Pumps

42

Figure 5-3 Wi-Fi Management

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

When a device first connects to the Wi-Fi network, it needs to authenticate with either the agreed-upon PSK or certificate. The authentication process is tunneled from the AP back to the WLC, as shown in Figure 5-4. In the case of a PSK, the WLC verifies that the client key matches (see the green line in Figure 5-4). In the case of a certificate, the authentication process is passed from the WLC to the Cisco ISE for validation by using remote authentication dial-in user service (RADIUS) protocol (see the yellow line in Figure 5-4). Upon successful authentication, the device negotiates an encryption key and is granted link layer network access.

NIST SP 1800-8B: Securing Wireless Infusion Pumps

43

Figure 5-4 Wi-Fi Authentication

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

Once authentication is complete, typical network client activity is allowed. Figure 5-5 shows how DHCP is used to contact the router to obtain network configuration information for the device (see the red line in Figure 5-5). Once the network is configured, the infusion pump will attempt to connect to its provisioned pump server address on the enterprise network in the biomedical engineering zone (see the green line in Figure 5-5).

NIST SP 1800-8B: Securing Wireless Infusion Pumps

44

Figure 5-5 Wi-Fi Device Access

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

Using an enterprise-grade Wi-Fi system can simplify transitions to more secure protocols by decoupling Wi-Fi SSIDs and security parameters from the Wi-Fi spectrum and physical Ethernet connections. First, every AP only needs to broadcast on a single Wi-Fi channel (in each band) and can broadcast multiple SSIDs. This helps avoid interference due to multiple independent wireless systems trying to use the same frequencies. Second, each SSID can be tied to its own VLAN. This means that logical network separation can be maintained in Wi-Fi without having to use additional spectrum. Third, multiple SSIDs can be tied to the same VLAN or standard Ethernet network. Each SSID can have its own security configuration as well. For example, in our use case, we have two different authentication mechanisms for granting access to the same network: one configured for WPA2-PSK, and the other for so-called enterprise certificates. This can be particularly useful for gradual transitions from old security mechanisms (e.g., Wireless Encryption Protocol [WEP], Wi-Fi Protected Access [WPA]) or old PSKs to newer ones, instead of needing to transition all devices at one time. In our case, to determine which devices may need reconfiguration to use certificates, we used the WLC to identify exactly which devices are using old PSK SSIDs. Once this number is reduced to an acceptable level, the old PSK SSID can be turned off, and only certificate-based authentication will be allowed.

NIST SP 1800-8B: Securing Wireless Infusion Pumps

45

5.3.1.3

Network Access Control

This section describes how network access control using a wireless LAN, as shown above, is applied to the wireless infusion pumps.

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

Before we describe network access controls, it is important to discuss each pump’s wireless protection protocol. There are three available wireless protection protocols (WEP, WPA, and WPA2). We also describe in-depth options for WPA2-PSK. Finally, we describe options for WPA2 across the HDO enterprise. Many of the infusion pumps used in this NCCoE project are newer models, capable of supporting various wireless protocols. For HDOs, WPA2 is the recommended wireless protocol to use. WEP and WPA are considered insufficient for appropriately securing wireless network sessions. Our architecture is designed to support multiple levels of access control for different groups of users. The architecture is configured to use WPA2-PSK and WPA2-Enterprise security protocols for secure wireless connections to accommodate the best available security mechanisms, depending on which vendor products your organization uses. Please note that a wireless infusion pump manufactured prior to 2004 may not be able to support these newer wireless security protocols [41]. The WPA2-PSK is often referred to as PSK mode. This protocol is designed for small office networks and does not require an external authentication server. Each wireless network device encrypts the network traffic by using a 256-bit key. All pumps used in our example implementation support this wireless security mode, and each pump performed properly when using this mode. However, because all devices share the same key in a PSK mode using WPA2-PSK, if credentials are compromised, then significant manual reconfiguration and change management will be required. WPA2 enterprise security uses 802.1x/EAP. By using 802.1x, an HDO can leverage the existing network infrastructure’s centralized authentication services, such as a RADIUS authentication server, to provide a strong client authentication. Cisco recommends that WPA2 Enterprise, which uses the Advanced Encryption Standard (AES) cypher for optimum encryption, be used for wireless medical devices, if available. We implemented WPA2 Enterprise with EAP-TLS security mode on several of our pumps to demonstrate that these pumps can leverage the public key infrastructure (PKI) to offer strong endpoint authentication and the strongest encryption possible for highly secure wireless transmissions. In this mode, pumps were authenticated to the wireless network with a client certificate issued by DigiCert Certificate Authority. During the authentication process, the pump’s certificates are validated against a RADIUS authentication server using Cisco ISE. Automatic logoff features allow the system to terminate the endpoints from the network after a predetermined time of inactivity. Organizations manage and control the client certificates via the certificate authority. With this capability, organizations may revoke and renew certificates as needed. Once WPA2 is selected as the appropriate wireless protection protocol, certificates may be issued to authenticate infusion pumps by using 802.1x/EAP-TLS mode, as illustrated in Figure 5-6 [27], [28], [29], [30], [31], [32], [33], [34], [35], [36], [37], [42], [46], [47], [48], [49].

NIST SP 1800-8B: Securing Wireless Infusion Pumps

46

Figure 5-6 Network Access Control

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

Certificate issuance involves the following three stages, which are outlined by the green and orange shaded objects in Figure 5-6: 1. Certificate Registration Step 1: Request a certificate from the DigiCert Certificate Authority, which is a Certificate Register Manager. Request pump certificates through a standalone computer connected to the internet by using DigiCertUtil, a certificate request tool, on behalf of a pump. Step 2: The approved certificates are exported to the pumps by using the specific tools provided by pump vendors. Typically, this activity is performed by a biomedical engineer. Step 3: Install the certificate into the Cisco ISE application.

NIST SP 1800-8B: Securing Wireless Infusion Pumps

47

2. Authentication Authentication is performed by the Cisco ISE application to validate the pump certificate under the 802.1x/EAP-TLS. During the network access authentication procedure, the AP will pass the certification information to the ISE server for validation. Once passed, the connection between the pump and the pump server will be established, and the data transmitted between the pump and the AP is encrypted. 3. Certificate Management This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

Certificate management will provide services to revoke certificates when they are no longer in use, and will also manage the certificate revocation list, along with any related processes for renewing old certificates. The detailed process for setting up the 802.1x network authentication for pump and pump server communication is documented in the How-To portion of the guide (NIST SP 1800-8C).

5.3.1.4

Remote Access

Many medical devices and their backend management systems require access by manufacturers for device repairs, configuration, software, and firmware patching and updates, or maintenance. A vendor network segment (VendorNet) is designed to provide vendors with external privileged access to their manufactured components and systems that reside within an HDO’s architecture. In the NCCoE lab, a VendorNet is implemented using TDi ConsoleWorks as a security proxy. ConsoleWorks is a vendoragnostic interface that gives organizations the ability to manage, monitor, and record virtually any activities in the IT infrastructure that come from external vendors. Communication using TDi ConsoleWorks for vendor access to products does not require the installation of software agents to establish connections for managing and monitoring targeted components. Established connections are persistent to facilitate IT operations, enforce security, and maintain comprehensive audit trails. All information collected by ConsoleWorks is time-stamped and digitally signed to ensure information accuracy, empower oversight, and meet compliance requirements. Through a standard web browser, ConsoleWorks can be securely accessed from any geographical location, eliminating the need for administrators and engineers to be locally present to perform their work. Remote access is only allowed through a specific set of security mechanisms. This includes using a VPN client at the network layer, as shown in Figure 5-7, for vendors to authenticate to the VPN server [43], [44], [50].

NIST SP 1800-8B: Securing Wireless Infusion Pumps

48

Figure 5-7 Remote Access VPN

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

After the VPN connection is established at the application layer, the security proxy will restrict who can access certain resources within the enterprise network, as depicted in Figure 5-8. Vendors also authenticate to the Hypertext Transfer Protocol Secure (HTTPS)-based security proxy (see the red line in Figure 5-7). Based on the vendor’s role, the security proxy will facilitate a Remote Desktop Protocol (RDP) connection to equipment in the biomedical engineering zone via the vendor support network (see the green line in Figure 5-7). The credentials that are used to authenticate the RDP connection are stored by the security proxy and are not disclosed to the vendor.

NIST SP 1800-8B: Securing Wireless Infusion Pumps

49

The remote access firewall/router is configured so that direct access between the VPN and vendor support is denied and the only allowed path is through the security proxy (see the stop sign in Figure 5-7). Additionally, the firewall/router can further restrict what is accessible at the network layer from the security proxy. The security proxy is granted access to the internet to support patching and to email alerts. The public IP address of the external firewall is configured to forward VPN traffic to the IP address of the VPN server [35], [43], [44], [45], [46], [48], [50], [51]. Figure 5-8 Remote Access This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

5.3.1.5

External Access

A guest network allows visitors or patients to access internet services during their visit. As explained in Section 5.3.1.1.2, the work traffic tends not to be of a clinical nature, but is offered as a courtesy to hospital visitors and patients to access the internet. The external firewall marks the boundary between

NIST SP 1800-8B: Securing Wireless Infusion Pumps

50

the enterprise and the internet. As shown in Figure 5-9, this is the only point in the network where network address translation (NAT) is used. Additionally, the guest network for personal devices connects to the internet though the external firewall. The guest network is configured such that traffic cannot go between the enterprise and guest networks—only out to the internet. This is denoted by the stop sign in Figure 5-9. The external firewall is configured to provide the necessary services for guest users to use the internet, such as DHCP, which allows dynamic addressing for anyone. Typically, consumer equipment is connected here, such as smart phones, tablets, and personal entertainment systems (Figure 5-9) [45]. This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

Figure 5-9 External

NIST SP 1800-8B: Securing Wireless Infusion Pumps

51

5.3.2 Pump Controls Wireless infusion pumps have the following controls: ▪

endpoint protection

▪

hardening

▪

data protection

5.3.2.1

Endpoint Protection

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

Traditional security relies on the network border to provide security protection to its internal nodes, using security technologies, such as application firewalls, proxy gateways, centralized virus scan, and network IDS and IPS. The challenge faced here, however, is that medical devices, such as wireless infusion pumps, may not have the capability to have third-party tools installed or deployed to effectively provide control. As such, endpoint protection is applied to that equipment where possible. This may limit endpoint protection controls to servers or workstations that may operate in the hospital infrastructure. Nodes, such as networked medical devices, should participate in their own security. Otherwise, the device may become the weakest element in the enterprise and present a risk to the entire HDO network. To avoid the single point of failure caused by an unsecured node, every system should have an appropriate combination of local protections applied to it. These protections include code signing, antitampering, encryption, access control, whitelisting, and others. Controls are layered across a technology stack, with the intent to improve the overall cybersecurity posture, recognizing that there may be limitations to applying a full set of controls for each node.

5.3.2.2

Hardening

Wireless infusion pumps and their servers are considered computing endpoints, when it comes to hardening the software contained within these devices. Medical devices may contain third-party products, including proprietary or commercial embedded operating systems, network communication modules, runtime environments, web services, or databases. Because these products can contain vulnerabilities, medical devices may also inherit these vulnerabilities just by using the products [2], [3], [7], [9], [25]. Therefore, it is important to identify all software applications used on medical devices, implement securing and hardening procedures recommended by the manufacturers, and apply timely patches and updates to guard against any newly discovered threats. Hardening may include the following actions: ▪

disabling unused or unnecessary communication ports and services

▪

changing manufacturer default administrative passwords

▪

securing remote APs, if there are any

NIST SP 1800-8B: Securing Wireless Infusion Pumps

52

▪

confirming that the firmware version is up-to-date

▪

ensuring that hashes or digital signatures are valid

However, please note that most infusion pumps do not have the same level of storage resources and Central Processing Unit (CPU) processing capability as those provided for personal computers and servers.

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

Hardening or modifying devices, configurations, or settings should be performed based on guidance from the manufacturer. Wireless infusion pumps are medical devices that adhere to FDA regulation, where the manufacturer has validated appropriate functionality based on a defined configuration. Identified vulnerabilities should be disclosed to the manufacturer, who may advise on appropriate mitigation approaches and provide patches, fixes, and updates where appropriate.

5.3.2.3

Data Protection

The two primary reasons for data protection are confidentiality and integrity. Medical devices may contain patient data, such as the patient’s name, MRN, gender, age, height, weight, procedure number, medication and treatment information, or other identifiers that may constitute PHI. PHI must be appropriately protected (e.g., through encryption or other safeguard measures that would prevent unauthorized disclosure of such information). Infusion pumps may also contain configuration data, such as drug libraries specifying dosage and threshold limits. This data must be protected against compromises as well. Our defense-in-depth approach for data integrity involves sandboxing the critical system files stored in pump servers by using DCS:SA and by encrypting messages when communicating between a medical infusion pump and the backend infusion management system, via Internet Protocol Security or secure-sockets-layer encryption (e.g., HTTPS, TLS).

5.3.3 Pump Server Controls Pump server features vary. Usually, a pump server can be used to distribute firmware, the drug library, or other software updates used inside the devices, or as a tool for providing services, such as reporting and device asset management. Data collected by the infusion pump server is valuable for further analysis to provide reports on trends, compliance checking, and to measure infusion safety. Because pump servers connect to infusion pumps to deliver and receive infusion-related information, it is also important to secure the infusion pump server and its associated applications, databases, and communication channels.

NIST SP 1800-8B: Securing Wireless Infusion Pumps

53

5.3.3.1

User Account Controls

Access to the pump server typically implements username/password authentication. After the pump server is installed, an initial step is to define the password policy that applies to users accessing the pump server. When managing user accounts for a pump server, common cybersecurity hygiene should include the following actions:

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

▪

changing factory default passwords

▪

enforcing password policies

▪

assigning each user’s access level by using the least-privilege principle

▪

if supported, using centralized access management, such as LDAP, for user account management at the enterprise level APT:

▪

configuring automatic logoff

5.3.3.2

Communication Controls

Pump servers interface with many other systems or components, such as databases, web services, and web portals. Communications between different systems can be configured. Pump servers might provide choices for selecting unsecure or secure Transport Control Protocol (TCP)/IP ports for communication. We recommend using secure (e.g., stateful, encrypted network sessions) ports for message communication or for package download. There may be a default setting for the communication interval, in number of seconds, for communication attempts between the server and the pump. Be sure to properly set this idle timeout setting.

5.3.3.3

Application Protection

Application protection refers to software applications running on the pump servers. Most of the software application security concerns and security controls that are used on traditional personal computers and servers may also be applied to pump servers to protect data integrity and confidentiality. These control measures may include those listed below: ▪

trusted applications

▪

stronger access control mechanisms for pumps and pump servers

▪

better key management

▪

application whitelisting

▪

sandboxing applications

▪

performing code-signing verification for newly installed software

NIST SP 1800-8B: Securing Wireless Infusion Pumps

54

▪

applying the latest patches and software updates

▪

encrypting message data in transit or data at rest

Server security baseline integrity is achieved via the use of three Symantec cybersecurity products on an enterprise network with a specific focus on wireless infusion pumps:

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

▪

DCS:SA

▪

SEP

▪

APT:N

Each of these Symantec products provides protections for components in the enterprise systems in different levels. With pre-built policies, the DCS:SA server that is installed can provide out-of-the-box HIDS and HIPS by monitoring and preventing suspicious server activities on pump servers. The use of DCS:SA also provides the host firewall service for controlling inbound and outbound network traffic to and from a protected server. Using DCS:SA, the configuration settings, files, and file systems in the pump server can be locked down using policy-based least-privilege access controls to restrict application and operating-system behavior and to prevent file and system tampering. Like DCS:SA, SEP provides similar protection for endpoint devices and servers. SEP features in-memory exploit mitigation and antivirus file protection to block malware from infecting protected endpoint servers. This will reduce the possibility of zero-day exploits on popular software that may not have been properly patched or updated. To protect endpoint servers, an SEP agent must be installed on servers. ATP:N can provide network-based protection of medical device subnets by monitoring internal inbound and outbound internet traffic. It can also be used as a dashboard to gain visibility to all devices and all network protocols. In addition, if ATP:N is integrated with the SEP, ATP:N can then monitor and manage all network traffic from the endpoints and provide threat assessments for dangerous activity to secure medical devices on an enterprise network. The use of these Symantec security products is depicted in Figure 5-10. As depicted, the ATP:N will inspect all traffic going through the core network switch via port mirroring between the enterprise services, biomedical engineering, and medical device zones. Wired traffic within each zone is also inspected via port mirroring on the switches used in those zones.

NIST SP 1800-8B: Securing Wireless Infusion Pumps

55

Figure 5-10 Pump Server Protection

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

5.3.4 Enterprise-Level Controls 5.3.4.1

Asset Tracking and Inventory Control

Medical asset management includes asset tracking and asset inventory control. Asset tracking is a management process used to maintain oversight of the equipment, using anything from simple methods (such as pen and paper), to record equipment, to more-sophisticated information technology asset management (ITAM) platforms. HDOs can use asset tracking to verify that a device is still in the possession of the assigned, authorized users. Some more-advanced tracking solutions may provide service for locating missing or stolen devices. Inventory management is also important throughout a medical device’s life cycle. Inventory tracking should not be limited to hardware inventory management. It should also be expanded to include software, software versions, and data stored and accessed in the devices, for security purposes. HDOs

NIST SP 1800-8B: Securing Wireless Infusion Pumps

56

can use this type of inventory information to verify compliance with security guidelines and to check for exposure of confidential information to unauthorized entities.

5.3.4.2

Monitoring and Audit Controls

Logging, monitoring, and auditing procedures are essential security measures that can be used to help HDOs prevent incidents and provide an effective response when a security breach occurs. The activities can include: This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

▪

logging - recording events to appropriate logs

▪

monitoring - overseeing the events for abnormal activities, such as scanning, compromises, malicious code, and DoSs in real time

▪

auditing - reviewing and checking these recorded events to find abnormal situations or to evaluate if the applied security measures are effective.

By combining the logging, monitoring, and auditing features, an organization will be able to track, record, review, and respond to abnormal activities, and provide historical records when needed. Many malware and virus infections can be almost completely avoided by using properly configured firewalls or proxies with regularly updated knowledge databases and filters to prevent connections to known malicious domains. It is also important to review your firewall logs for blocked connection attempts so that you can identify the attached source and remedy infected devices if needed. In our example implementation, user audit controls—simple audits—are in place. Although additional SIEM tools and centralized log aggregation tools are recommended to maximize security event analysis capabilities, aggregation and analytics tools like these are considered out of scope for this project iteration. Each system is monitored for compliance with a secure configuration baseline. Each system is also monitored for risks to known good, secure configurations by vulnerability scanning tools. In our project, the Cisco AP, the Cisco ISE as the RADIUS authentication server, the TDi VendorNet, and the pump servers from each vendor, are all equipped with proper monitoring and logging capabilities. Real-time monitoring for events happening within these systems can be analyzed and compared to the baseline. If any abnormal behavior occurs, it can be detected. The auditing of data was considered out of scope for this reference design because the absence of an actual data center made auditing behavior impractical.

5.4 Final Architecture The target architecture, depicted in Figure 5-11, indicates the implementation of network segmentation and controls as described by this practice guide. Segmentation identified nine zones, ranging from the guest network zone to the medical device zone, and includes zones for the Wi-Fi infrastructure and the core network infrastructure. The zoned concept implements firewall/router devices to enforce segmentation, with the firewall enforcing limited trust relationships between each zone. For example,

NIST SP 1800-8B: Securing Wireless Infusion Pumps

57

access between the biomedical engineering zone and the medical device zone is limited to only the ports identified by the vendor and the associated pump server. Noted in the diagram (Figure 5-11) are processes that have impact on the overall architecture. Security controls are implemented to enforce encryption on network sessions. For Wi-Fi, leveraging standard protocols, such as WPA2-PSK and WPA2 Enterprise, created a secure channel for the pumps to communicate with the APs, and to use TLS to secure the communication channel from the pumps to the server. Figure 5-11 Target Architecture This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8. NIST SP 1800-8B: Securing Wireless Infusion Pumps

58

6 Life-Cycle Cybersecurity Issues Configuration management throughout a device’s life cycle is a key process that is necessary for the support and maintenance of medical devices [3]. NIST SP 1800-5: IT Asset Management discusses ITAM, and, although the focus of the document pertains to financial services, similar challenges exist in healthcare [52]. Establishing a product-life-cycle management program addresses a few of the risks noted in previous sections of this guide, and should be considered as part of a holistic program for managing risks associated with infusion pump deployments. This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

Figure 6-1 illustrates a typical life cycle for an asset, and this model can be applied to medical devices. The subsections below discuss the essential cybersecurity activities that should occur during specific phases of the asset life cycle. Figure 6-1 Asset Life Cycle [53]

NIST SP 1800-8B: Securing Wireless Infusion Pumps

59

6.1 Procurement Asset life-cycle management typically begins with Strategy, Plan, and Design phases, which lead into procurement (the Procure phase). These phases are opportunities for hospitals to define requirements and to identify where security controls may be implemented on infusion pumps or other devices that the hospital intends to acquire.

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

Phases leading into procurement enable the HDO, reseller, or manufacturer to ensure that the equipment that the HDO will deploy offers the appropriate combination of security and functionality required to render patient care. These phases also enable the hospital to implement appropriate security controls to safeguard the device and the information that it may store or process. Purchasers at HDOs may request manifests or architectural guidance on secure deployment of the equipment, and may perform research on products and the manufacturers that they have selected. While performing the research, HDOs may begin a risk assessment process to ensure that risks are mitigated. Manufacturers maintain a document referred to as the MDS2 (Manufacturer Disclosure Statement for Medical Devices) that an HDO may review, enabling the HDO to determine possible vulnerabilities and risks [54]. Hospital purchasers may also determine if vulnerabilities exist in the proposed equipment by reviewing the FDA-hosted MAUDE (Manufacturer and User Facility Device Experience) database. Hospitals should also obtain any necessary training, education, and awareness material from the manufacturer, and should educate staff about the deployment, operation, maintenance, and security features available on their equipment. HDOs might consider writing user-friendly documentation to ensure that staff can use the equipment with confidence and competence. Performing research and risk analysis during the phases leading into procurement will allow HDOs to make informed decisions. For further reference, we note that the Mayo Clinic has produced a best-practice document that discusses procurement [55].

6.2 Operation After hospitals procure their equipment, they onboard it during the Operate and Maintain phases. Equipment purchasers should apply asset management processes (e.g., asset tagging and entry into a configuration management database or some other form of inventory tracking), and should have standard baseline configurations implemented. Wireless infusion pumps may need to be configured to connect to a hospital’s Wi-Fi network (medical device zone, as depicted in Section 5.3.1.2, Medical Device Zone’s Wireless LAN) and implement digital certificates to allow for device authentication. As noted above, hospitals should implement some type of configuration management database or asset inventory that captures granular information about the device. Implementing an ITAM mechanism enables the hospital to have visibility into their infusion pump deployment, with captured information

NIST SP 1800-8B: Securing Wireless Infusion Pumps

60

that describes the make/model, firmware, operating system, software versions, the applied configuration along with change history, and the physical location within the hospital. Regular maintenance of the ITAM would reduce risks, for example, that may emerge based on loss/theft, as well as provide a central knowledge repository that allows the hospital to coordinate any required maintenance or refresh.

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

As part of deployment, hospitals should apply practices noted by the manufacturer (e.g., regarding access control and authentication). As noted above, digital certificates should be installed to allow for device authentication to Wi-Fi, but engineers should implement access control and auditing mechanisms where applicable.

6.3 Maintenance Pump manufacturers have two types of systems that require updating: the pumps and the pump servers. Pumps may implement control systems in firmware (writeable, non-volatile storage that may include an embedded operating or other control system). Control systems may be maintained through an update process that involves replacing all or parts of the operating or control system. Server components may be implemented on more-conventional IT systems, using commercial operating systems (e.g., Windows or Linux variants). Another aspect of configuration management that HDOs will want to pursue is patching. Patching, known colloquially as bug fixing, does not require a full replacement of software and is generally performed on pump servers. The patch frequency to which manufacturers generally adhere is monthly for patches and yearly for updates. This observation on timing comes from industry, not NIST—and is considered standard practice, rather than advice. In addition to identifying patch frequency, organizations must be aware of likely vulnerabilities and the risks that they introduce into the enterprise, and then decide whether a patch should be applied. NIST SP 800-40, Guide to Enterprise Patch Management Technologies [56], discusses the importance of patch management, as well as the challenges.

6.4 Disposal The Dispose phase of the ITAM life cycle comes into play when products reach their end of life and are removed from hospital service. Wireless infusion pumps have increased in sophistication and in the information that each device may use, process, or store. The information found on pumps and related equipment may include sensitive information or information that may be regarded as PHI. As such, hospitals should seek to implement mechanisms to ensure that any sensitive information and PHI are removed from all storage areas that a pump or its system components may maintain. Practices to remove that information may be found in NIST SP 800-88, Guidelines for Media Sanitation [26].

NIST SP 1800-8B: Securing Wireless Infusion Pumps

61

7 Security Characteristics Analysis We identified the security benefits of the reference design, how they map to NIST Cybersecurity Framework Subcategories, and the mitigating steps to secure the reference design against potential new vulnerabilities [10], [14].

7.1 Assumptions and Limitations This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

Our security analysts reviewed the reference architecture and considered if the integration described in this guide would meet security objectives. The analysts purposely avoided testing products, and readers should not assume any endorsement or diminution of the value of any vendor products. Although we have aimed to be thorough, we counsel those who are following this guide to evaluate their own implementation to adequately gauge risks specific to their organizations.

7.2 Application of Security Characteristics Using the NIST Cybersecurity Framework Subcategories to organize our analysis allowed us to systematically consider how well the reference design supports specific security activities, and provided additional confidence that the reference design addresses our use-case security objectives. The remainder of this subsection discusses how the reference design supports each of the identified Cybersecurity Framework Subcategories [10].

7.2.1 Supported NIST Cybersecurity Framework Subcategories The reference design focuses primarily on the Identify and Protect Function areas (their Subcategories) of the NIST Cybersecurity Framework. Specifically, the reference design supports the following Subcategories: ▪

three Subcategories in the NIST Cybersecurity Framework Identify Function area, under the Categories of Asset Management, Business Environment, and Risk Assessment

▪

Subcategories from each Category of the NIST Cybersecurity Framework Protect Function area, except for the Awareness and Training Categories

We discuss these NIST Cybersecurity Framework Subcategories in the following subsections.

7.2.1.1

ID.AM-5: Resources (e.g., Hardware, Devices, Data, Time, and Software) Are Prioritized Based on Their Classification, Criticality, and Business Value

To address this Subcategory of the Identify Function, we conducted an asset inventory as part of the risk management process. For this project, we identified assets and entered them into the Clearwater Compliance IRM|Analysis™ tool. This risk analysis tool categorized project resources into types of assets. Additionally, it characterized the system, enabling us to address the criticality of our resources. Our

NIST SP 1800-8B: Securing Wireless Infusion Pumps

62

project only partially satisfies the Resources subcategory, as we focused on technical solutions and did not write a business impact assessment or business continuity plan.

7.2.1.2

ID.BE-1: The Organization’s Role in the Supply Chain Is Identified and Communicated

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

Organizations who may be using this guide are the end users of medical devices. NIST SP 800-53, control SA-12, most directly applies to such end users because it directs users to define which security safeguards to employ to protect against supply chain threats [14]. Our implementation uses network segmentation to limit exposure to the wireless infusion pump from other areas within a hospital network. This is done because, if a vulnerability is identified in a device, segmentation and access control will help safeguard the medical device until the vulnerability can be properly addressed.

7.2.1.3

ID.RA-1: Asset Vulnerabilities Are Identified and Documented

Given a reasonably long life cycle, even the best-designed electronic asset will eventually be impacted by a vulnerability. Medical devices can have a long product life cycle, per AAMI TIR57, “Device or platform used for decades” [9], [25]. Identifying vulnerabilities in an asset may occur via various means. Some vulnerabilities may be identified through onsite testing; however, it is often the manufacturer or a researcher who will find the vulnerability. An effective risk management program is essential to reduce the likelihood that an identified vulnerability will be exploited. This implementation uses a combination of risk analysis tools and methods to help reduce the impact that a vulnerability may have on the build.

7.2.1.4

PR.AC-1: Identities and Credentials Are Issued, Managed, Revoked, and Audited for Authorized Devices, Users, and Processes

Following the segmentation approach used to separate hospital networks into zones, our implementation employs role-based security, which limits access based on who actually need to access the pump. HDO users with no business need are not permitted access to pumps, pump servers, or related components. Most users, including biomedical staff, are granted access via Active Directory. Although our NCCoE lab did not use single sign-on (SSO), using SSO can make pump access seamless to an end user. How to manage credentials of clinicians who directly operate the pump is beyond the scope of this guide. Remote access is necessary to maintain proper functionality of infusion pumps, but the mechanism for gaining and controlling remote access varies depending on the user type. Hospital staff, such as biomedical engineers, remotely access pumps through a VPN and hardened gateway at the application layer. Such users are considered trusted HDO staff with access to other network resources throughout the enterprise. Pump manufacturers who may need to reach a device for maintenance or troubleshooting can gain access only into a VendorNet zone, from which they can access pumps and pump servers, but not other

NIST SP 1800-8B: Securing Wireless Infusion Pumps

63

zones in the enterprise. Our example implementation uses ConsoleWorks for authentication, role-based access control, and recording system management actions of remote vendor activity.

7.2.1.5

PR.AC-4: Access Permissions and Authorizations Are Managed, Incorporating the Principles of Least Privilege and Separation of Duties

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

This NIST Cybersecurity Framework Subcategory is supported for the pumps and pump servers with DCS:SA. The configuration settings, files, and file systems in the pump server are restricted, thereby implementing policy-based least-privilege access control. DCS:SA restricts application and operatingsystem behavior and prevents unauthorized users from tampering with files and systems. Least privilege is also addressed via the network design itself. By limiting user access to only the zones where a user has a business need for access, the architecture seeks to enforce the concepts of least privilege and separation of duties.

7.2.1.6

PR.AC-5: Network Integrity Is Protected (e.g., network segregation, network segmentation)

Network segmentation is a key function of this reference design. Segregating the core network, guest network, business office, database server, enterprise services, clinical services, and biomedical engineering zones from the medical device zone reduces the risk of medical devices being negatively impacted from malware or an exploit in another zone. Using a combination firewall/router device to segregate the zones also limits risk to the enterprise, should a vulnerability be exploited within the medical device zone.

7.2.1.7

PR.DS-2: Data-in-Transit Is Protected

Data in transit occurs when data travels from the drug library on a pump server to an infusion pump. The information being passed most frequently will be the types of drugs and dosage range. This information is not PHI; however, the availability and integrity of this information are important. This project uses WPA2-AES, which authenticates pumps to the wireless network, with the client certificate issued by DigiCert Certificate Authority.

7.2.1.8

PR.DS-6: Integrity Checking Mechanisms Are Used to Verify Software, Firmware, and Information Integrity

This NIST Cybersecurity Framework Subcategory is supported with server and agent products to monitor and lock-down configuration settings, files, and file systems in the pump server by using the policybased least-privilege access control. This limits the applications and operating system to the expected behavior, and reduces the likelihood of digital tampering with the system.

NIST SP 1800-8B: Securing Wireless Infusion Pumps

64

7.2.1.9

PR.IP-1: A Baseline Configuration of Information Technology/Industrial Control Systems Is Created and Maintained Incorporating Security Principles (e.g., Concept of Least Functionality)

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

A mature cybersecurity program follows a documented secure baseline for traditional information technology components and medical devices. This NCCoE project has implemented hardening for each component used in the build, and has documented the steps taken. This initial step produces a secure baseline configuration. Because this project uses five different types of wireless infusion pumps, the baseline is of limited use; however, in a healthcare organization with many medical devices and multiple biomedical and IT professionals, it is essential to develop and implement a baseline configuration for vulnerability management.

7.2.1.10 PR.MA-2: Remote Maintenance of Organizational Assets Is Approved, Logged, and Performed in a Manner that Prevents Unauthorized Access We controlled remote access to pump vendors by implementing ConsoleWorks, a software tool that records all of the actions performed over a connection, thereby providing an audit trail that documents vendor activity.

7.2.1.11 PR.PT-1: Audit/Log Records Are Determined, Documented, Implemented, and Reviewed in Accordance with Policy Our example implementation supports this NIST Cybersecurity Framework Subcategory by enabling logging on all devices in two ways: with a logging capability and with a process of identifying which events the log will record. Although our project employs auditing, and recognizes its importance in a cybersecurity program, log aggregation and implementing a log review process, albeit vital activities, are beyond this project’s scope.

7.2.1.12 DE.AE-1: A Baseline of Network Operations and Expected Data Flows for Users and Systems Is Established and Managed As we did with systems and medical devices, we took a least-functionality approach when configuring the network. We followed best practices for configuring firewalls based on a default deny, restricted SSID broadcast, and for limiting the power of wireless signals. This NIST Cybersecurity Framework Subcategory is supported by the Symantec IDS component of the reference design. This tool identifies, monitors, and reports anomalous network traffic that may indicate a potential intrusion. Endpoint protection implements policies for the expected behavior, and alerts when activities occur outside the usual patterns.

NIST SP 1800-8B: Securing Wireless Infusion Pumps

65

7.3 Security Analysis Summary

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

Our reference design’s implementation of security surrounding wireless infusion pumps helps reduce risk from a pump, even if a vulnerability is identified in a pump, by creating a more secure environment for medical devices. The key feature is network segmentation. Supporting this zone approach, our project build follows security best practices to harden devices, monitor traffic, and limit access via the wireless network to only authorized users. Any organization following this guide must conduct its own analysis of how to employ the elements, in their own environment, that were discussed here. It is essential that organizations follow security best practices to address potential vulnerabilities and to minimize any risk to the operational network.

8 Functional Evaluation We conducted a functional evaluation of our example implementation to verify that several common provisioning functions used in our laboratory test worked as expected. We also needed to ensure that the example solution would not alter normal pump and pump-server functions. The functional test plan provided in Section 8.1 outlines our test cases, the purposes, and the desired outcomes. The subsequent subsections explain the functional tests in more detail, and list the procedures for each of the functional tests.

8.1 Functional Test Plan Table 8-1 Functional Test Plan Test Case

Purpose

Desired Outcomes

WIP-1: Network Segmentation

Test the effectiveness of network segmentation

All firewall rules for each segment are implemented correctly, as designed.

WIP-2: Data Center Security

Test the effectiveness of the DCS:SA to see that it follows defined policies

The inbound and outbound network traffic to and from servers is controlled per host firewall rules.

WIP-3: Endpoint Protection

Test the effectiveness of the SEP to ensure that it follows defined policies

A bad file is detected, and the planned installation action is blocked.

WIP-4: Advanced Threat Protection

Test the effectiveness of the ATP:N to ensure that it follows defined policies

The URLs in the blacklist are blocked. The URLs in the whitelist are allowed.

NIST SP 1800-8B: Securing Wireless Infusion Pumps

66

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

Test Case

Purpose

Desired Outcomes

WIP-5: Protected Remote Access

Test the effectiveness of the remote access controls

The vendor can access only what has been granted for access with the correct privileges.

WIP-6: Pump and Pump Server Network Connection

Confirm that the installation and configuration of pumps and pump servers are fully completed

Pumps and pump servers are connected to the network, and pumps communicate to the corresponding pump servers.

WIP-7: Pump and Pump Server Basic Functions

Test a set of operational events between pumps and pump servers

Pumps are connected to the corresponding pump server, able to perform a set of operational events.

8.1.1 Test Case WIP-1 Table 8-2 Test Case WIP-1 Test Case Name

Network Segmentation

Description

• Show that the WIP solution allows the inbound and outbound traffic of a given zone as per its design. • Show that the WIP solution blocks the inbound and outbound traffic of a given zone as per its design.

Preconditions

• WIP network segmentation is implemented. • Internal firewall rules of each zone are defined and implemented. • The ASAs are configured to use stateful filtering, so return traffic is automatically allowed if the initial connection is allowed. Everything not explicitly allowed in a rule is denied.

Procedure

1. Use the medical device zone and the biomedical engineering zone as a test example. 2. Review the port and communication protocol requirements from each tested pump vendor, for the pump and the corresponding pump server. 3. Configure the ASA firewall access list to open only the needed ports and to allow access only to necessary protocols. 4. Everything not explicitly allowed in a rule is denied.

NIST SP 1800-8B: Securing Wireless Infusion Pumps

67

Test Case Name

Network Segmentation

Result

1. Review the ASA configuration file to verify that the ASA firewall is configured to only allow communication with a specific protocol and port as specified by the pump vendors. All other communication between these two segments will be denied and blocked using a command, such as “show access-list | include eq,” to see the opened ports. 2. Use network discovery scanning tools, such as nmap, to check the open, closed, or filtered ports.

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

8.1.2 Test Case WIP-2 Table 8-3 Test Case WIP-2 Test Case Name Description

Data Center Security

Preconditions

• DCS:SA is installed and configured.

Show that the WIP solution detects files that are defined in policy and that apply the file and system tampering prevention methods by locking down files • The File and System Tamper Prevention policy is set. • Windows_Baseline_detect_TEST is used as the baseline for server hardening.

Procedure

There are two admin applications for the DCS:SA, the console admin and the portal admin. The console admin is the thick client, and the portal admin is the thin client. The console is used to create and modify the policy, and the portal is used to publish the policy. The portal URL is http://<portal IP Address> 1. Log into the DCS Console. 2. Select the Policy > Work Space > Pump Server folder. 3. Select the Detection tab to show the detection polices. 4. You should see a preinstalled policy: Windows_Baseline_detect_Test. Double-click it to open a detailed policy editing window for configuration. 5. Create a policy for hardening the server, such as “do not allow any file to be installed on the server.” 6. Enable the policy. 7. Publish the policy.

Result

Test to verify that no file is allowed to be installed on the protected server.

NIST SP 1800-8B: Securing Wireless Infusion Pumps

68

8.1.3 Test Case WIP-3 Table 8-4 Test Case WIP-3 Test Case Name Description

Endpoint Protection / Advance Threat Protection

Preconditions

• SEP is installed and configured.

Show that the WIP solution has the capability to detect a “bad” file and to act (i.e., stop installing that bad file).

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

• Define the antivirus signature rule. • Create a bad file that is part of the antivirus signature rule. Procedure

1. Make sure that the test server has a SEP agent installed and enabled. 2. From the server machine, open an Internet Explorer browser, and then type this URL in the browser: http://test.symantecatp.com. This is a test site provided by Symantec, containing some unharmful links for testing purposes. 3. Click some links, such as antivirus test, from the list to install some suspicious software on the test server. 4. The installation should be blocked by the server’s SEP, and the violation incident should be reported in the ATP. 5. To view the violation in ATP, log into the ATP server from a browser in a server that can access that sub network, such as the Active Directory server. 6. Type this URL in the browser: http://<hostname>. 7. View any violation incidents from the ATP to verify that the bad link is blocked. a. If wanted, one can dive into the details to see to which bad sites it tried to connect. b. Close the open incident report after the review.

Result

To verify that the ATP:N and Symantec deployment and configuration offer the needed security protection to prevent malware installed in a server, and to view the violation, in ATP, log into the ATP server from a browser in a server that can access the network, where the tested server is located. 1. View any violation incidents from the ATP to verify that the bad link is blocked. 2. Check the details to see to which bad sites it tried to connect. 3. Close open incident report after the review.

NIST SP 1800-8B: Securing Wireless Infusion Pumps

69

8.1.4 Test Case WIP-4 Table 8-5 Test Case WIP-4 Test Case Name

Advanced Threat Protection

Description

Show that the WIP solution has effective network threat protection based on network intrusion prevention, URL, and firewall policies.

Preconditions

• The ATP:N is installed and configured.

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

• Firewall and browser protection rules are defined. Procedure

1. Log onto a server with ATP:N installed. 2. Access a malicious website. 3. Check the results.

Result

See Test Case WIP-3.

8.1.5 Test Case WIP-5 Table 8-6 Test Case WIP-5 Test Case Name

Protected Remote Access

Description

Show that the WIP solution has the protected remote access capability. The VendorNet concept was created out of a need to give vendors more-restricted remote access, compared to NIST/NCCoE/MITRE staff, to a lab. VendorNet is an NCCoE network created for each lab that is tied to an Active Directory group. This group of vendors is then allowed to access the lab through VendorNet. VendorNet hosts controlled access mechanisms, such as ConsoleWorks, file transfer servers, or other remote access proxy services.

Preconditions

• VendorNet is created. • TDi ConsoleWorks is installed and configured. • The ConsoleWorks profile and user are created.

Procedure

1. Using public internet, remotely log onto the NCCoE VPN. 2. Log onto ConsoleWorks by using the following URL: https://consoleworks.nccoe.nist.gov. 3. From the graphical menu, select View to view graphical connections. (Note: Each external vendor can only view the resources assigned to them.) 4. Access the granted hosts. 5. Perform the allowed operations as specified. 6. Check the results.

NIST SP 1800-8B: Securing Wireless Infusion Pumps

70

Test Case Name

Protected Remote Access

Result

1. Verify that the vendor can access the associated pump server by using VendorNet and ConsoleWorks. 2. Verify that the vendor can perform the preassigned operational activities. 3. Verify that the vendor cannot perform unauthorized operations, such as some administration task (e.g., adding a new user account). 4. Verify that all activities performed by the external vendor are logged and can be audited as needed.

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

8.1.6 Test Case WIP-6 Table 8-7 Test Case WIP-6 Test Case Name

Pump and Pump Server Network Connection

Description

Show that the WIP solution establishes the wireless network connection between each vendor’s pumps and their corresponding pump server.

Preconditions

• The wireless router with the pre-shared password SSID has been set up. • Infusion pump servers have been installed and configured. • Infusion pumps have been installed and configured using WPA2-PSK or WPA2 Enterprise / EAP-TLS for a secure wireless network connection. • Cisco ISE is installed and configured with root Certificate Authority installed.

Procedure

1. Turn on the pump. 2. Check the wireless indicator. 3. Check the AP and ISE administration portals for device connection and authentication status. 4. Check the infusion pump server management tool for discovered pumps.

Result

• Both the AP and ISE portal should indicate that the pumps are successfully connected to the network. • The pump server admin portal should indicate that the pump is online and in use. (Note: The way that the pump server portal displays these messages is vendor-dependent.) • In the case of WPA2 Enterprise / EAP-TLS wireless access mode, the Cisco ISE should display that the pumps are successfully authenticated.

NIST SP 1800-8B: Securing Wireless Infusion Pumps

71

8.1.7 Test Case WIP-7 Table 8-8 Test Case WIP-7 Test Case Name

Pump and Pump Server Basic Functions

Description

Show that the WIP solution supports the basic operational events for each vendor’s pumps and their corresponding pump server.

Preconditions

• The test results of WIP-6 are successful.

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

• The drug library for a specific pump has been created by a pharmacist, and validation has been performed. • The drug library has been successfully published or loaded to the infusion pump server to be tested. Procedure

1. From the pump server, send the new version of the drug library to its pumps. Listed below is an example procedure used by Hospira to send the drug library to its pump by using the MedNet software server: a. Log into a MedNet software server. b. Request the download of the drug library to one or more pumps. c. MedNet displays the drug library download status as “Pending.” d. MedNet, using MedNet Server, forwards the drug library to the infusion pump selected. e. The pump infuser downloads the drug library from the MedNet server. f. The pump infuser sends a download status update to the MedNet server to indicate that the drug library is successfully downloaded. Wait for installation. g. The pump server displays the download status as “On Pump.” h. The operator of the pump powers-down the pump. Choose to install the new drug library when prompted by the infuser. i. The pump sends the update status to MedNet to indicate that the drug library was successfully installed, and a “Completed” download status is displayed. 2. From the pump server, send the new version of software updates to its pumps (using a Smiths Medical pump as an example). Using the PharmGuard pump server, packages containing data, such as device configuration data or firmware, specific to an installed Smiths Medical device model, can be installed. The package tested is provided by Smiths Medical. a. Log into a PharmGuard server.

NIST SP 1800-8B: Securing Wireless Infusion Pumps

72

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

Test Case Name

Pump and Pump Server Basic Functions b. Select Package Deployment from the Asset Management dropdown menu. All previously-deployed packages, if any, are listed. c. Click Add Package. d. Click Browse to navigate to and select the package file. e. Click Upload to upload the package. After the package file is read, information about the package is displayed in the package table. f. Select the package that you would like to deploy, and then click View/Deploy. The package detailed information is displayed. g. Click Deploy to deploy the new package. h. Enter the name for the deployment, and specify a start deploy. i. Enter the required password, and then click Continue. j. After you confirm the package deployment, the name of the newly deployed package displays in the Deployment list with the status of “Active.” k. To check if a package has been received by the individual pump associated with the package deployment, you need to check the device itself.

Result

Use the device or the corresponding pump server portal to verify that the intended package has been successfully deployed. How this information is displayed is device-specific and manufacturer-specific. For more information, please consult documentation for specific devices.

9 Future Considerations During our development of this project and practice guide, we did not implement several components; however, these omitted components should be considered. We did not implement a commercially available EHR system. EHRs are often regarded as central within a hospital. Additionally, we did not implement a central asset inventory management tool, or mechanisms to perform malware detection or network monitoring in the medical device zone. Limitations on control implementation exist based on endpoint capabilities. As infusion pumps continue to evolve as part of an IoMT ecosystem, capabilities, including endpoint encryption and identity and access management may become available, thus further enhancing automated management of the medical device zone. Over the course of time, manufacturers may consider the application of future technologies, or may need to address unanticipated threats in a novel fashion. An update to this practice guide could evaluate these components and other control mechanisms that may become available in the future.

NIST SP 1800-8B: Securing Wireless Infusion Pumps

73

Appendix A

Threats

Some potential known threats in the healthcare environments that use network-connected medical devices, such as wireless infusion pumps, are listed below.

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

▪

Targeted attacks: Targeted attacks are threats involving actors that attempt to compromise the pump and system components directly affecting pump operations, including the pump, pump server, drug library, or drug library management systems. Actors who perform such targeted attacks may be external; in other words, those who attempt to access the pump system through the public internet, or via vendor support networks or virtual private networks (VPNs). There may also be internal actors, such as those on staff, who may be involved in accidental misconfiguration or who possess provisioned access and abuse their granted privileges, or patients or other visitors who attempt to modify the behavior of a pump.

▪

Advanced persistent threats (APTs): APTs occur when the sophisticated threat actor attempts to place malicious software on the pump or pump system components, which may enable that threat actor to perform unauthorized actions, either on the pump system itself, or as a pivot point to cause adverse conditions for hospital internal systems that may have reachability from the pump network environment. Placement of malicious software may or may not cause adverse scenarios on the pump or its system components.

▪

Disruption of service – denial-of-service (DoS) and distributed-denial-of-service (DDoS) attacks: DoS or DDoS attacks may be components found in a broader APT scenario. Such attacks are intended to cause the unavailability of the pump or pump system components, thus rendering providers with a degraded capability to fulfill patient care.

▪

Malware infections: In this type of attack, a threat actor places malicious software on the pump, likely as part of an APT campaign, or to cause an adverse situation on the pump or pump systems. One example of a malware infection is that of ransomware, in which malicious software would cause a disruption of the availability of the pump for standard operations, and may affect patient safety by preventing providers from leveraging system functionality (e.g., the ability to associate the pump with a patient and deliver medications), or by preventing the pump from effectively using safety measures, such as the drug library.

▪

Theft or loss of assets: This threat type applies when the pump or pump system components are not accounted for in an inventory, thereby leading to a degraded availability of equipment, and a possible breach of protected health information (PHI).

▪

Unintentional misuse: This threat considers the possibility that the pump or its components may be unintentionally misconfigured or used for unintended purposes, including errors introduced through the misapplication of updates to operating systems or firmware, misconfiguration of settings that allow the pump to achieve network connectivity or communication to the pump server, misapplication or errors found in the drug library, or errors associated with fluids applied to pumps.

NIST SP 1800-8B: Securing Wireless Infusion Pumps

74

▪

Vulnerable systems or devices directly connected to the device (e.g., via Universal Serial Bus [USB], or other hardwired non-network connections): Extending from the unintentional misuse of the device, this threat considers scenarios in which individuals may expose devices or server components by using external ports or interfaces for purposes outside the device’s intended use (e.g., to extract data to portable storage media, to connect a mobile device to recharge that device’s battery). In leveraging ports for unintended purposes, threat actors may enable malicious software to migrate to the pump or server components, or to create adverse conditions based on unexpected connections.

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8. NIST SP 1800-8B: Securing Wireless Infusion Pumps

75

Appendix B

Vulnerabilities

Some typical vulnerabilities that may arise when using wireless infusion pumps are listed below.

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

▪

Lack of asset inventory: Deficient or out-of-date inventories represent a cybersecurity control deficiency that may lead to the loss/theft of devices or equipment, with little chance for the hospital to recover or take recourse against losses. Deficient asset inventory controls, when paired with a credible threat, such as the loss or theft of a device or equipment, raise risks associated with a provider’s ability to render patient care, and may expose protected health information (PHI) to unauthorized individuals.

▪

Long useful life: Infusion pumps are designed to perform clinical functions for several years, and they tend to have long-term refresh rates. One vulnerability associated with infrequent refresh is that each device’s technological attributes may become obsolete or insufficient to support patching or updating, or cybersecurity controls that may become available in the future.

▪

Information/data vulnerabilities: •

Lack of encryption on private/sensitive data at rest: Pump devices may have local persistent storage, but they may not have a means to encrypt data stored on the device. Locally stored data may include sensitive configuration information, or patient information, including possible PHI.

•

Lack of encryption on transmitted data: Sensitive data should be safeguarded in transit as well as at rest. Where capabilities exist, pumps and server components should employ encryption on the network or when transmitting sensitive information. An inability to safeguard data in transit, by using appropriate encryption capabilities, may expose sensitive information or allow malicious actors to determine how to connect to a pump or server to perform unauthorized activities.

•

Unauthorized changes to device calibration or configuration data: Modifications made to pump or server components that are not accurately approved, deployed, or tracked may lead to adverse operation of the equipment. Hospitals should ensure that changes to the device calibration or configuration, or the modification of safeguard measures, such as the drug library, are performed and managed using appropriate measures.

•

Insufficient data backup: Providing backup and recovery capability is a common cybersecurity control to ensure that healthcare delivery organizations (HDOs) can restore services in a timely fashion after an adverse event. Hospitals should perform appropriate pump system backup and restore functions.

•

Lack of capability to de-identify private/sensitive data: As a secondary cybersecurity control to data encryption, hospitals may wish to consider the ability to de-identify or obfuscate sensitive information or PHI.

•

Lack of data validation: Data used and captured by infusion pumps and associated server components may require data integrity assurance to support proper functioning and

NIST SP 1800-8B: Securing Wireless Infusion Pumps

76

patient safety. Mechanisms should be used to provide assurance that data cannot be altered inappropriately. ▪

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

▪

Device/endpoint (infusion pump) vulnerabilities: •

Debug-enabled interfaces: Interfaces required to support or troubleshoot infusion pump functions should be identified, with procedures noted to indicate when interfaces are available, and how interfaces may be disabled when not required for troubleshooting or system updates/fixes.

•

Use of removable media: Infusion pumps that include external or removable storage should be identified. Cybersecurity precautions are necessary because the use of removable media may lead to inappropriate information disclosure, and may provide a viable avenue for malicious software to migrate to the pump or server components.

•

Lack of physical tamper detection and response: Infusion pumps may involve physical interaction, including access to interfaces used for debugging. HDOs should enable mechanisms to prevent physical tampering with infusion pump devices, including alerting appropriate personnel whenever a pump or its server components are manipulated or altered.

•

Misconfiguration: Mechanisms should be used to ensure that pump configurations are well-managed and may not be configured to produce adverse conditions.

•

Poorly protected and patched devices: Like the misconfiguration vulnerability, HDOs should implement processes to protect/patch/update pumps and server components. This may involve including controls on the device, or provisions that allow for external controls that would prevent exposure to flaws or weaknesses.

User or administrator accounts vulnerabilities: •

Hard-coded or factory-default passcodes: Processes or mechanisms should be added to prevent the use of so-called hard-coded or factory-default passcodes. This would overcome a common information-technology (IT) systems deficiency in the use of authentication mechanisms for privileged access to devices, in terms of using weak passwords or passcodes protection. Weak authentication mechanisms that are well-known or published degrade the effectiveness of authentication control measures. HDOs should implement a means to update and manage passwords.

•

Lack of role-based access and/or use of principles of least privilege: When access management roles and principles of least privilege are poorly designed, they may allow the use of a generic identity (e.g., a so-called admin account) that enables a greater access capability than necessary. HDOs should implement processes to limit access to privileged accounts, infusion pumps, and server components, and should use accounts or identities that tie to specific functions, rather than providing/enabling the use of super user, root, or admin privileges.

NIST SP 1800-8B: Securing Wireless Infusion Pumps

77

▪

•

Dormant accounts: Accounts or identities that are not used may be described as dormant. Dormant account information should be disabled or removed from pumps and server components.

•

Weak remote access controls: When remote access to a pump and/or server components is required, access controls should be appropriately enforced to safeguard each network session and to ensure appropriate authentication and authorization.

IT network infrastructure vulnerabilities:

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

•

Lack of malware protection: Pumps and server components should be protected using processes or mechanisms to prevent malware distribution. When malware protection cannot be implemented on endpoint devices, malware detection should be implemented to protect network traffic.

•

Lack of system hardening: Pumps and server components should incorporate protective measures that limit functionality only to the specific capabilities necessary for infusion pump operations.

•

Insecure network configuration: HDOs should employ a least-privilege principle when configuring networks that include pumps and server components, limiting network traffic capabilities, and enforcing limited trust between zones identified in hospital environments.

•

System complexity: When implementing network infrastructure controls, hospitals should seek device models and communications paths/patterns that limit complexity where possible.

NIST SP 1800-8B: Securing Wireless Infusion Pumps

78

Appendix C

Recommendations and Best Practices

The recommendations listed below address additional security concerns that are worthy of consideration. If applied, these additional recommendations will likely reduce risk factors or prevent them from becoming greater risks. Associated best practices for reducing the overall risk posture of infusion pumps are also included in the following list. ▪ This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

▪

▪

Consider forming a Medical Device Security Committee composed of staff members from biomedical services, information technology (IT), and InfoSec that would report to C-suite governance. •

Enable this committee to manage the security of all network-connected medical devices. Too often, for example, the biomedical services team is solely responsible for cradle-tograve maintenance of all aspects of medical devices, including cybersecurity, leaving IT and InfoSec staff out of the loop.

•

Develop a committee charter with roles and responsibilities and reporting requirements to the C-suite and Board of Directors.

Consider the physical security of mobile medical devices, including wireless infusion pumps. •

Designate a secure and lockable space for storing these devices when they are not in use.

•

Ensure that only personnel with a valid need have access to these spaces. Ideally, a proximity system with logging should be used and frequently audited.

Create a comprehensive inventory of medical devices, and actively manage it. •

▪

Ensure that any Cybersecurity Incident Response Plan includes medical devices. •

▪

Consider the use of radio-frequency identification (RFID) or real-time locating systems (RTLS) technologies to assist with inventory processes and to help staff locate devices that have been moved without documentation.

Recently, the Food and Drug Administration (FDA) and the Industrial Control Systems Cyber Emergency Response Team (ICS-CERT) have both issued cybersecurity vulnerability advisories for medical devices. This was the first major warning to covered entities regarding medical device vulnerabilities. Most covered entities have not incorporated medical device response into their planning.

Ensure that pumps cannot step down to a Wireless Encryption Protocol (WEP) encrypted network. •

WEP is a compromised encryption protocol that should NEVER be used in operational wireless networks.

•

Operating any form of IT equipment, including medical devices, over a WEP network will result in the potential for data compromise and a regulatory breach.

NIST SP 1800-8B: Securing Wireless Infusion Pumps

79

•

▪

Any wireless network should be using, at a minimum, Wi-Fi Protected Access II (WPA2). This protocol implements the National Institute of Standards and Technology (NIST)-recommended Advanced Encryption Standard (AES).

Put in place an Information Security department, and functionally separate it from the IT department. This is necessary to ensure that operational IT personnel are not responsible for any information security measures, which may otherwise lead to a fox-guarding-the-hen-house situation.

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

•

Enable a separate InfoSec department to report to the Chief Information Security Officer (CISO), rather than to the Chief Information Officer (CIO).

•

Make this organization part of the Medical Device Security Committee.

▪

Create an operational information security program. This can take the form of an in-house Security Operations Center (SOC) to monitor information systems and initiate cybersecurity incident response, including monitoring potential exploits of medical devices, as necessary. Alternatively, organizations may wish to consider a Managed Security Service Provider (MSSP) to perform these duties.

▪

Ensure that vendor management includes the evaluation of information security during the due diligence phase of any related procurement processes. Too often, the Information Security team is not brought in until after contracts have been signed. •

When purchasing medical devices, ensure that devices incorporate the latest cybersecurity controls and capabilities.

•

Understand roles and responsibilities related to upgrades, patching, password management, remote access, etc., to ensure the cybersecurity of products or services.

▪

Consider media access control (MAC) address filtering to limit the exposure of unauthorized devices attempting to access the network. This would identify a bad actor attempting to access a medical device from within the network through an exposed wired Ethernet port.

▪

Develop or update policies and procedures to ensure a holistic approach to deployment, sanitization, and reuse of medical devices; include the Medical Device Security Committee.

NIST SP 1800-8B: Securing Wireless Infusion Pumps

80

Appendix D

Acronyms

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

AAMI

Advancement of Medical Instrumentation

AES

Advanced Encryption Standard

ANSI

American National Standards Institute

AP

Access Point

APT

Advanced Persistent Threat

ASA

Adaptive Security Appliance

ASM

Alaris System Maintenance

ATP:N

Advanced Threat Protection: Network

BD

Becton, Dickinson and Company

CAPWAP

Control and Provisioning of Wireless Access Points

CFC

NIST Cybersecurity Framework Core

CFR

Code of Federal Regulations

CIO

Chief Information Officer

CISO

Chief Information Security Officer

COI

Community of Interest

CRADA

Cooperative Research and Development Agreement

DCS:SA

Data Center Security: Server Advanced

DDoS

Distributed Denial of Service

DHCP

Dynamic Host Configuration Protocol

DNS

Domain Name System

DoS

Denial of Service

EAP

Extensible Authentication Protocol

EHR

Electronic Health Record

FDA

Food and Drug Administration

FIPS

Federal Information Processing Standards

FTP

File Transfer Protocol

HDO

Healthcare Delivery Organization

HIDS

Host Intrusion Detection System

HIPAA

Health Insurance Portability and Accountability Act

HIPS

Host Intrusion Prevention System

HTTPS

Hypertext Transfer Protocol Secure

NIST SP 1800-8B: Securing Wireless Infusion Pumps

81

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

ICS-CERT

Industrial Control Systems Cyber Emergency Response Team

IDS

Intrusion Detection System

IEC

International Electrotechnical Commission

IEEE

Institute of Electrical and Electronics Engineers

IoC

Indicator of Compromise

IoMT

Internet of Medical Things

IoT

Internet of Things

IP

Internet Protocol

IPS

Intrusion Prevention System

ISE

Identity Services Engine

ISO

International Standards Organization

IT

Information Technology

ITAM

Information Technology Asset Management

KRACK

Key Reinstallation Attack

LAN

Local Area Network

LDAP

Lightweight Directory Access Protocol

LVP

Large Volume Pump

MAC

Medium Access Control

MAUDE

Manufacturer and User Facility Device Experience

MDISS

Medical Device Innovation, Safety & Security Consortium

MDRAP

Medical Device Risk Assessment Platform

MSSP

Managed Security Service Provider

NAT

Network Address Translation

NCCoE

National Cybersecurity Center of Excellence

NIST

National Institute of Standards and Technology

NVD

National Vulnerability Database

OSPF

Open Shortest Path First

PAC

Process Access Control

PCU

Patient Care Unit

PHI

Protected Health Information

PKI

Public Key Infrastructure

PSK

Pre-Shared Key

NIST SP 1800-8B: Securing Wireless Infusion Pumps

82

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

RADIUS

Remote Authentication Dial-In User Service

RDP

Remote Desktop Protocol

RFID

Radio-Frequency Identification

RMF

Risk Management Framework

RTLS

Real-Time Locating Systems

SD

Secure Digital

SEP

Symantec Endpoint Protection

SIEM

Security Information and Events Management

SOC

Security Operations Center

SP

Special Publication

SSID

Service Set Identifier

SSO

Single Sign-On

TCP

Transmission Control Protocol

TIR

Technical Information Report

TLS

Transport Layer Security

U.S.

United States

URL

Uniform Resource Locator

USB

Universal Serial Bus

VLAN

Virtual Local Area Network

VPN

Virtual Private Network

WEP

Wired Equivalent Privacy

WLC

Wireless LAN Controller

WPA

Wi-Fi Protected Access

WPA2

Wi-Fi Protected Access II

NIST SP 1800-8B: Securing Wireless Infusion Pumps

83

Appendix E [1]

[2] This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

[3]

[4]

[5]

[6]

[7]

[8]

References

FDA, Infusion Pumps Total Product Life Cycle: Guidance for Industry and FDA Staff, December 2, 2014. http://www.fda.gov/downloads/medicaldevices/deviceregulationandguidance/guidancedocum ents/ucm209337.pdf [accessed 2/7/18]. FDA, Content of Premarket Submissions for Management of Cybersecurity in Medical Devices: Guidance for Industry and Food and Drug Administration Staff, October 2, 2014. http://www.fda.gov/downloads/medicaldevices/deviceregulationandguidance/guidancedocum ents/ucm356190.pdf [accessed 2/7/18]. FDA, Postmarket Management of Cybersecurity in Medical Devices: Guidance for Industry and Food and Drug Administration Staff, December 28, 2016. https://www.fda.gov/ucm/groups/fdagov-public/@fdagov-meddevgen/documents/document/ucm482022.pdf [accessed 2/7/18]. Department of Homeland Security (DHS), Attack Surface: Healthcare and Public Health Sector, Bulletin 201205040900. https://info.publicintelligence.net/NCCIC-MedicalDevices.pdf [accessed 2/8/18]. IHE PCD Technical Committee, Medical Equipment Management (MEM): Overview and Profile Roadmap, Version 1, IHE Patient Care Device (PCD) Technical Framework White Paper, Integrating the Healthcare Enterprise (IHE), Oak Brook, IL, 2009. http://www.ihe.net/Technical_Framework/upload/IHE_PCD_Medical-EquipmentManagement_MEM_White-Paper_V1-0_2009-09-01.pdf [accessed 2/7/18]. IHE PCD Technical Committee, Medical Equipment Management (MEM): Cybersecurity, IHE Patient Care Device (PCD) White Paper, Integrating the Healthcare Enterprise (IHE), Oak Brook, IL, 2011. http://www.ihe.net/Technical_Framework/upload/IHE_PCD_WhitePaper_MEM_Cyber_Security_Rev2-0_2011-05-27.pdf [accessed 2/7/18]. FDA, Guidance for Industry: Cybersecurity for Networked Medical Devices Containing Off-theShelf (OTS) Software, January 14, 2005. http://www.fda.gov/downloads/MedicalDevices/DeviceRegulationandGuidance/GuidanceDoc uments/ucm077823.pdf [accessed 2/7/18]. IHE PCD Technical Committee, Medical Equipment Management (MEM): Medical Device Cyber Security – Best Practice Guide, Revision 1.1, IHE Patient Care Device (PCD) White Paper, Integrating the Healthcare Enterprise (IHE), Oak Brook, IL, 2015. http://www.ihe.net/uploadedFiles/Documents/PCD/IHE_PCD_WP_CyberSecurity_Rev1.1_2015-10-14.pdf [accessed 2/7/18].

NIST SP 1800-8B: Securing Wireless Infusion Pumps

84

[9]

[10] [11] This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

[12]

[13]

[14]

[15]

[16]

AAMI TIR57: 2016: Principles for medical device security – Risk management, Advancement of Medical Instrumentation (AAMI) Technical Information Report (TIR)57, AAMI, Arlington, VA, June 5, 2016. Cybersecurity Framework, National Institute of Standards and Technology [Web site], http://www.nist.gov/itl/cyberframework.cfm [accessed 2/7/18]. Joint Task Force Transformation Initiative, Guide for Conducting Risk Assessments, NIST Special Publication (SP) 800-30 Revision 1, National Institute of Standards and Technology, Gaithersburg, Maryland, September 2012. http://nvlpubs.nist.gov/nistpubs/Legacy/SP/nistspecialpublication800-30r1.pdf [accessed 2/7/18]. Joint Task Force Transformation Initiative, Guide for Applying the Risk Management Framework to Federal Information Systems: A Security Life Cycle Approach, NIST Special Publication (SP) 800-37 Revision 1, National Institute of Standards and Technology, Gaithersburg, Maryland, February 2010. http://csrc.nist.gov/publications/nistpubs/800-37-rev1/sp800-37-rev1-final.pdf [accessed 2/7/18]. Joint Task Force Transformation Initiative, Managing Information Security Risk: Organization, Mission, and Information System View, NIST Special Publication (SP) 800-39, National Institute of Standards and Technology, Gaithersburg, Maryland, March 2011. http://nvlpubs.nist.gov/nistpubs/Legacy/SP/nistspecialpublication800-39.pdf [accessed 2/7/18]. Joint Task Force Transformation Initiative, Security and Privacy Controls for Federal Information Systems and Organizations, NIST Special Publication (SP) 800-53 Revision 4, National Institute of Standards and Technology, Gaithersburg, Maryland, April 2013. http://nvlpubs.nist.gov/nistpubs/SpecialPublications/NIST.SP.800-53r4.pdf [accessed 2/7/18]. International Electrotechnical Commission, Application of risk management for IT-networks incorporating medical devices – Part 2-1: Step-by-step risk management of medical IT-networks – Practical applications and examples, IEC Technical Report (IEC/TR) 80001-2-1 Edition 1.0, 2012. https://webstore.iec.ch/preview/info_iec80001-2-1%7Bed1.0%7Den.pdf [accessed 2/7/18]. International Electrotechnical Commission, Application of risk management for IT-networks incorporating medical devices – Part 2-2: Guidance for the disclosure and communication of medical device security needs, risks and controls, IEC Technical Report (IEC/TR) 80001-2-2 Edition 1.0, 2012. https://webstore.iec.ch/preview/info_iec80001-2-2%7Bed1.0%7Den.pdf [accessed 2/7/18].

NIST SP 1800-8B: Securing Wireless Infusion Pumps

85

[17]

[18]

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

[19]

[20]

[21]

[22] [23]

[24]

International Electrotechnical Commission, Application of risk management for IT-networks incorporating medical devices – Part 2-3: Guidance for wireless networks, IEC Technical Report (IEC/TR) 80001-2-3 Edition 1.0, 2012. https://webstore.iec.ch/preview/info_iec80001-23%7Bed1.0%7Den.pdf [accessed 2/7/18]. International Electrotechnical Commission, Application of risk management for IT-networks incorporating medical devices – Part 2-4: Application guidance – General implementation guidance for healthcare delivery organizations, IEC Technical Report (IEC/TR) 80001-2-4 Edition 1.0, 2012. https://webstore.iec.ch/preview/info_iec80001-2-4%7Bed1.0%7Den.pdf [accessed 2/7/18]. International Electrotechnical Commission, Application of risk management for IT-networks incorporating medical devices – Part 2-5: Application guidance – Guidance on distributed alarm systems, IEC Technical Report (IEC/TR) 80001-2-5 Edition 1.0, 2014. https://webstore.iec.ch/preview/info_iec80001-2-5%7Bed1.0%7Den.pdf [accessed 2/7/18]. M. Scholl, K. Stine, J. Hash, P. Bowen, A. Johnson, C. D. Smith, and D. I. Steinberg, An Introductory Resource Guide for Implementing the Health Insurance Portability and Accountability Act (HIPAA) Security Rule, NIST Special Publication (SP) 800-66 Revision 1, National Institute of Standards and Technology, Gaithersburg, Maryland, October 2008. http://www.nist.gov/customcf/get_pdf.cfm?pub_id=890098 [accessed 2/7/18]. HIPAA Regulations, hipaasurvivalguide.com (HSG) [Web site], http://www.hipaasurvivalguide.com/hipaa-regulations/hipaa-regulations.php [accessed 2/7/18]. HIPAA for Professionals, U.S. Department of Health & Human Services (HHS) [Web site], http://www.hhs.gov/ocr/privacy/hipaa/administrative/index.html [accessed 2/7/18]. American National Standards Institute / Association for the Advancement of Medical Instrumentation / International Electrotechnical Commission, Application of risk management for IT Networks incorporating medical devices – Part 1: Roles, responsibilities and activities, ANSI/AAMI/IEC 80001-1:2010, 2010. American National Standards Institute / Association for the Advancement of Medical Instrumentation / International Organization for Standardization, Medical devices – Application of risk management to medical devices, ANSI/AAMI/ISO 14971:2007, 2007 http://www.vcg1.com/files/ANSI_AAMI_ISO_149712007.pdf [accessed 2/7/18].

NIST SP 1800-8B: Securing Wireless Infusion Pumps

86

[25]

[26] This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

[27]

[28]

[29]

[30]

[31]

IHE PCD Technical Committee, Medical Equipment Management (MEM): Medical Device Cyber Security – Best Practice Guide, Draft for Public Comment Revision 1.0, IHE Patient Care Device (PCD) White Paper, Integrating the Healthcare Enterprise (IHE), Oak Brook, IL, 2015. http://ihe.net/uploadedFiles/Documents/PCD/IHE_PCD_WP_Cyber-Security_Rev1.0_PC_201507-01.pdf [accessed 2/8/18]. A. R. Regenscheid, L. Feldman, and G. A. Witte, Guidelines for Media Sanitization, NIST Special Publication (SP) 800-88 Revision 1, National Institute of Standards and Technology, Gaithersburg, Maryland, February 2015. https://www.nist.gov/publications/nist-specialpublication-800-88-revision-1-guidelines-media-sanitization [accessed 2/7/18]. K. Scarfone, M. Souppaya, and M. Sexton, Guide to Storage Encryption Technologies for End User Devices, NIST Special Publication (SP) 800-111, National Institute of Standards and Technology, Gaithersburg, Maryland, November 2007. http://nvlpubs.nist.gov/nistpubs/Legacy/SP/nistspecialpublication800-111.pdf [accessed 2/7/18]. D. R. Kuhn, V. C. Hu, W. T. Polk, and S. J. Chang, Introduction to Public Key Technology and the Federal PKI Infrastructure, NIST Special Publication (SP) 800-32, National Institute of Standards and Technology, Gaithersburg, Maryland, February 2001. http://nvlpubs.nist.gov/nistpubs/Legacy/SP/nistspecialpublication800-32.pdf [accessed 2/7/18]. E. Barker, W. Barker, W. Burr, W. T. Polk, and M. Smid, Recommendation for Key Management – Part 1: General (Revision 3), NIST Special Publication (SP) 800-57 Part 1 Revision 3, National Institute of Standards and Technology, Gaithersburg, Maryland, July 2012. http://csrc.nist.gov/publications/nistpubs/800-57/sp800-57_part1_rev3_general.pdf [accessed 2/7/18]. E. Barker, W. Barker, W. Burr, W. T. Polk, and M. Smid, Recommendation for Key Management – Part 2: Best Practices for Key Management Organization. NIST Special Publication (SP) 800-57 Part 2, National Institute of Standards and Technology, Gaithersburg, Maryland, August 2005. http://nvlpubs.nist.gov/nistpubs/Legacy/SP/nistspecialpublication800-57p2.pdf [accessed 2/7/18]. E. Barker and Q. Dang, Recommendation for Key Management: Part 3: Application-Specific Key Management Guidance, NIST Special Publication (SP) 800-57 Part 3 Revision 1, National Institute of Standards and Technology, Gaithersburg, Maryland, January 2015. http://nvlpubs.nist.gov/nistpubs/SpecialPublications/NIST.SP.800-57Pt3r1.pdf [accessed 2/7/18].

NIST SP 1800-8B: Securing Wireless Infusion Pumps

87

[32]

[33]

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

[34] [35]

[36]

[37]

[38]

[39]

[40]

K. Scarfone, D. Dicoi, M. Sexton, and C. Tibbs, Guide to Securing Legacy IEEE 802.11 Wireless Networks, NIST Special Publication (SP) 800-48 Revision 1, National Institute of Standards and Technology, Gaithersburg, Maryland, July 2008. http://csrc.nist.gov/publications/nistpubs/80048-rev1/SP800-48r1.pdf [accessed 2/7/18]. S. Frankel, B. Eydt, L. Owens, and K. Scarfone, Establishing Wireless Robust Security Networks: A Guide to IEEE 802.11i, NIST Special Publication (SP) 800-97, National Institute of Standards and Technology, Gaithersburg, Maryland, February 2007. http://nvlpubs.nist.gov/nistpubs/Legacy/SP/nistspecialpublication800-97.pdf [accessed 2/7/18]. Institute of Electrical and Electronics Engineers, Port Based Network Access Control, IEEE 802.1X, 2001. http://www.ieee802.org/1/pages/802.1x.html [accessed 2/7/18]. Institute of Electrical and Electronics Engineers, Wireless LAN Medium Access Control (MAC) and Physical Layer (PHY) Specifications, IEEE 802.11, 2017. http://www.ieee802.org/11/ [accessed 2/7/18]. U.S. Department of Commerce. Security Requirements for Cryptographic Modules, Federal Information Processing Standards (FIPS) Publication 140-2, May 2001. http://csrc.nist.gov/groups/STM/cmvp/standards.html [accessed 2/7/18]. W. T. Polk, K. McKay, and S. Chokhani, Guidelines for the Selection, Configuration, and Use of Transport Layer Security (TLS) Implementations, NIST Special Publication (SP) 800-52 Revision 1, National Institute of Standards and Technology, Gaithersburg, Maryland, April 2014. http://nvlpubs.nist.gov/nistpubs/SpecialPublications/NIST.SP.800-52r1.pdf [accessed 2/7/18]. HIPAA Security Rule Crosswalk to NIST Cybersecurity Framework, DHHS Office for Civil Rights, Washington, DC, 2016. https://www.hhs.gov/sites/default/files/nist-csf-to-hipaa-security-rulecrosswalk-02-22-2016-final.pdf [accessed 2/7/18]. International Organization for Standardization/International Electrotechnical Commission, Information technology – Security techniques – Information security management systems – Requirements, ISO/IEC 27001:2013, 2013. https://www.itgovernance.co.uk/shop/Product/isoiec-27001-2013-iso-27001-standard-ismsrequirements [accessed 2/7/18]. S. Iddir, P. Thongpradit, E. Sparnon, and I. Singureanu, IHE Patient Care Device User Handbook, 2011 Edition, Integrating the Healthcare Enterprise (IHE), Oak Brook, IL, August 2011. http://www.ihe.net/Technical_Framework/upload/IHE_PCD_User_Handbook_2011_Edition.pd f [accessed 2/7/18].

NIST SP 1800-8B: Securing Wireless Infusion Pumps

88

[41]

[42]

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

[43]

[44]

[45]

C. Mah and S. Higgins, Cisco Medical-Grade Network (MGN) 2.0-Security Architectures, Cisco, San Jose, CA, 2012. https://www.cisco.com/c/dam/en_us/solutions/industries/docs/healthcare/mgn_security.pdf [accessed 2/8/18]. FDA, Radio Frequency Wireless Technology in Medical Devices: Guidance for Industry and Food and Drug Administration Staff, August 12, 2013. http://www.fda.gov/downloads/MedicalDevices/DeviceRegulationandGuidance/GuidanceDoc uments/ucm077272.pdf [accessed 2/7/18]. M. Souppaya and K. Scarfone, Guidelines for Managing the Security of Mobile Devices in the Enterprise, NIST Special Publication (SP) 800-124 Revision 1, National Institute of Standards and Technology, Gaithersburg, Maryland, June 2013. http://nvlpubs.nist.gov/nistpubs/SpecialPublications/NIST.SP.800-124r1.pdf [accessed 2/8/18]. S. Frankel, K. Kent, R. Lewkowski, A. D. Orebaugh, R. W. Ritchey, and S. R. Sharma, Guide to IPsec VPNs, NIST Special Publication (SP) 800-77, National Institute of Standards and Technology, Gaithersburg, Maryland, December 2005. http://csrc.nist.gov/publications/nistpubs/800-77/sp800-77.pdf [accessed 2/7/18]. K. Scarfone and P. Hoffman, Guidelines on Firewalls and Firewall Policy, NIST Special Publication (SP) 800-41 Revision 1, National Institute of Standards and Technology, Gaithersburg, Maryland, September 2009. http://csrc.nist.gov/publications/nistpubs/800-41-Rev1/sp800-41rev1.pdf [accessed 2/7/18].

[46]

Institute of Electrical and Electronics Engineers, IEEE Standard for Ethernet, IEEE 802.3, 2016. http://www.ieee802.org/3/ [accessed 2/7/18].

[47]

Institute of Electrical and Electronics Engineers, Bridges and Bridged Networks, IEEE 802.1Q, 2014. http://www.ieee802.org/1/pages/802.1Q.html [accessed 2/7/18].

[48]

[49]

[50]

S. Kent and K. Seo, Security Architecture for the Internet Protocol, Internet Engineering Task Force (IETF) Network Working Group Request for Comments (RFC) 4301, December 2005. https://tools.ietf.org/html/rfc4301 [accessed 2/7/18]. U.S. Department of Commerce. Advanced Encryption Standard (AES), Federal Information Processing Standards (FIPS) Publication 197, November 2001. http://csrc.nist.gov/publications/fips/fips197/fips-197.pdf [accessed 2/7/18]. K. Scarfone, P. Hoffman, and M. Souppaya, Guide to Enterprise Telework and Remote Access Security, NIST Special Publication (SP) 800-46 Revision 1, National Institute of Standards and Technology, Gaithersburg, Maryland, June 2009. http://csrc.nist.gov/publications/nistpubs/800-46-rev1/sp800-46r1.pdf [accessed 2/7/18].

NIST SP 1800-8B: Securing Wireless Infusion Pumps

89

[51]

[52]

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

[53] [54]

[55]

[56]

A. Singhal, T. Winograd, and K. Scarfone, Guide to Secure Web Services, NIST Special Publication (SP) 800-95, National Institute of Standards and Technology, Gaithersburg, Maryland, August 2007. http://csrc.nist.gov/publications/nistpubs/800-95/SP800-95.pdf [accessed 2/7/18]. M. Stone, C. Irrechukwu, H. Perper, and D. Wynne, IT Asset Management, NIST Special Publication (SP) 1800-5A, National Institute of Standards and Technology, Gaithersburg, Maryland, October 2015. https://nccoe.nist.gov/sites/default/files/library/sp1800/fs-itam-nistsp1800-5-draft.pdf [accessed 2/7/18]. Image source: http://wc1.smartdraw.com/cmsstorage/exampleimages/44b341d1-a502-465f854a-4e68b8e4bf75.png. Manufacturer Disclosure Statement for Medical Device Security (MDS2), Healthcare Information and Management Systems Society (HIMSS) [Web site], http://www.himss.org/resourcelibrary/MDS2 [accessed 2/8/18]. Vendor Deliverables to Initiate the Clinical Information Security Pre-Purchase Security Assessment, Mayo Clinic, Rochester, MN, 2017. http://www.mayo.edu/documents/vendordeliverables/doc-20358150 [accessed 2/7/18]. M. Souppaya and K. Scarfone, Guide to Enterprise Patch Management Technologies, NIST Special Publication (SP) 800-40 Revision 3, National Institute of Standards and Technology, Gaithersburg, Maryland, July 2013. https://nvlpubs.nist.gov/nistpubs/SpecialPublications/NIST.SP.800-40r3.pdf [accessed 2/7/18].

NIST SP 1800-8B: Securing Wireless Infusion Pumps

90

NIST SPECIAL PUBLICATION 1800-8C

Securing Wireless Infusion Pumps in Healthcare Delivery Organizations Volume C: How-to Guides

Gavin O’Brien National Cybersecurity Center of Excellence Information Technology Laboratory

Sallie Edwards Kevin Littlefield Neil McNab Sue Wang Kangmin Zheng The MITRE Corporation McLean, VA

August 2018 This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8

The first draft of this publication is available free of charge from: https://www.nccoe.nist.gov/sites/default/files/library/sp1800/hit-infusion-pump-nist-sp1800-8draft.pdf

DISCLAIMER Certain commercial entities, equipment, products, or materials may be identified in this document in order to describe an experimental procedure or concept adequately. Such identification is not intended to imply recommendation or endorsement by NIST or NCCoE, nor is it intended to imply that the entities, equipment, products, or materials are necessarily the best available for the purpose.

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

National Institute of Standards and Technology Special Publication 1800-8C, Natl. Inst. Stand. Technol. Spec. Publ. 1800-8C, 257 pages, (July 2018), CODEN: NSPUE2

FEEDBACK As a private-public partnership, we are always seeking feedback on our Practice Guides. We are particularly interested in seeing how businesses apply NCCoE reference designs in the real world. If you have implemented the reference design, or have questions about applying it in your environment, please email us at hit_nccoe@nist.gov.

National Cybersecurity Center of Excellence National Institute of Standards and Technology 100 Bureau Drive Mailstop 2002 Gaithersburg, MD 20899 Email: nccoe@nist.gov

NIST SP 1800-8C: Securing Wireless Infusion Pumps

i

NATIONAL CYBERSECURITY CENTER OF EXCELLENCE

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

The National Cybersecurity Center of Excellence (NCCoE), a part of the National Institute of Standards and Technology (NIST), is a collaborative hub where industry organizations, government agencies, and academic institutions work together to address businesses’ most pressing cybersecurity issues. This public-private partnership enables the creation of practical cybersecurity solutions for specific industries, as well as for broad, cross-sector technology challenges. Through consortia under Cooperative Research and Development Agreements (CRADAs), including technology partners—from Fortune 50 market leaders to smaller companies specializing in IT security—the NCCoE applies standards and best practices to develop modular, easily adaptable example cybersecurity solutions using commercially available technology. The NCCoE documents these example solutions in the NIST Special Publication 1800 series, which maps capabilities to the NIST Cyber Security Framework and details the steps needed for another entity to recreate the example solution. The NCCoE was established in 2012 by NIST in partnership with the State of Maryland and Montgomery County, Md. To learn more about the NCCoE, visit https://nccoe.nist.gov. To learn more about NIST, visit https://nist.gov.

NIST CYBERSECURITY PRACTICE GUIDES NIST Cybersecurity Practice Guides (Special Publication Series 1800) target specific cybersecurity challenges in the public and private sectors. They are practical, user-friendly guides that facilitate the adoption of standards-based approaches to cybersecurity. They show members of the information security community how to implement example solutions that help them align more easily with relevant standards and best practices and provide users with the materials lists, configuration files, and other information they need to implement a similar approach. The documents in this series describe example implementations of cybersecurity practices that businesses and other organizations may voluntarily adopt. These documents do not describe regulations or mandatory practices, nor do they carry statutory authority.

ABSTRACT Medical devices, such as infusion pumps, were once standalone instruments that interacted only with the patient or medical provider. However, today’s medical devices connect to a variety of health care systems, networks, and other tools within a healthcare delivery organization (HDO). Connecting devices to point-of-care medication systems and electronic health records can improve healthcare delivery processes; however, increasing connectivity capabilities also creates cybersecurity risks. Potential threats include unauthorized access to patient health information, changes to prescribed drug doses, and interference with a pump’s function. The NCCoE at NIST analyzed risk factors in and around the infusion pump ecosystem by using a questionnaire-based risk assessment to develop an example implementation that demonstrates how HDOs can use standards-based, commercially available cybersecurity technologies to better protect the infusion pump ecosystem, including patient information and drug library dosing limits. This practice guide will help HDOs implement current cybersecurity standards and best practices to reduce their cybersecurity risk, while maintaining the performance and usability of wireless infusion pumps.

NIST SP 1800-8C: Securing Wireless Infusion Pumps

ii

KEYWORDS authentication; authorization; digital certificates; encryption; infusion pumps; Internet of Things (IoT); medical devices; network zoning; pump servers; questionnaire-based risk assessment; segmentation; virtual private network (VPN); Wi-Fi; wireless medical devices

ACKNOWLEDGMENTS We are grateful to the following individuals for their generous contributions of expertise and time. This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

Name

Organization

Arnab Ray

Baxter Healthcare Corporation

Pavel Slavin

Baxter Healthcare Corporation

Phillip Fisk

Baxter Healthcare Corporation

Raymond Kan

Baxter Healthcare Corporation

Tom Kowalczyk

B. Braun Medical Inc.

David Suarez

Becton, Dickinson and Company (BD)

Robert Canfield

Becton, Dickinson and Company (BD)

Rob Suarez

Becton, Dickinson and Company (BD)

Robert Skelton

Becton, Dickinson and Company (BD)

Peter Romness

Cisco

Kevin McFadden

Cisco

Rich Curtiss

Clearwater Compliance

Darin Andrew

DigiCert

Kris Singh

DigiCert

Mike Nelson

DigiCert

Chaitanya Srinivasamurthy

Hospira Inc., a Pfizer Company (ICU Medical)

Joseph Sener

Hospira Inc., a Pfizer Company (ICU Medical)

Chris Edwards

Intercede

Won Jun

Intercede

Dale Nordenberg

Medical Device Innovation, Safety & Security Consortium (MDISS)

NIST SP 1800-8C: Securing Wireless Infusion Pumps

iii

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

Name

Organization

Jay Stevens

Medical Device Innovation, Safety & Security Consortium (MDISS)

Carlos Aguayo Gonzalez

PFP Cybersecurity

Thurston Brooks

PFP Cybersecurity

Colin Bowers

Ramparts

Bill Hagestad

Smiths Medical

Axel Wirth

Symantec Corporation

Bryan Jacobs

Symantec Corporation

Bill Johnson

TDi Technologies, Inc.

Barbara De Pompa Reimers

The MITRE Corporation

Sarah Kinling

The MITRE Corporation

Marilyn Kupetz

The MITRE Corporation

David Weitzel

The MITRE Corporation

Mary Yang

The MITRE Corporation

The Technology Partners/Collaborators who participated in this build submitted their capabilities in response to a notice in the Federal Register. Respondents with relevant capabilities or product components were invited to sign a Cooperative Research and Development Agreement (CRADA) with NIST, allowing them to participate in a consortium to build this example solution. We worked with: Technology Partner/Collaborator

Build Involvement

Baxter Healthcare Corporation

• Sigma Spectrum™ Large Volume Pump (LVP) Version 8 • Sigma Spectrum Wireless Battery Module Version 8 • Sigma Spectrum Master Drug Library Version 8 • Care Everywhere Gateway Server Version 14

B. Braun Medical Inc.

• Infusomat® Space Infusion System / Large-Volume Pumps • DoseTrac® Infusion Management Software / Infusion Pump Software

NIST SP 1800-8C: Securing Wireless Infusion Pumps

iv

Technology Partner/Collaborator

Build Involvement

Becton, Dickinson and Company (BD)

• Alaris® 8015 Patient Care Unit (PCU) Version 9.19.2 • Alaris Syringe Module 8110 • Alaris LVP Module 8100 • Alaris Systems Manager Version 4.2 • Alaris System Maintenance (ASM) Version 10.19

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

Cisco

• Aironet 1600 Series Access Point (AIR-CAP1602I-A-K9) • Wireless LAN [Local Area Network] (WLC) Controller 8.2.111.0 • Identity Services Engine (ISE) • Adaptive Security Appliance (ASA) • Catalyst 3650 Switch

Clearwater Compliance

• IRM|Pro™ • IRM|Analysis™

DigiCert

CertCentral® management account / Certificate Authority

Hospira Inc., a Pfizer Company (ICU Medical)

• Plum 360™ Infusion System Version 15.10 • LifeCare PCA™ Infusion System Version 7.02 • MedNet™ Version 6.2

Intercede

MyID®

Medical Device Innovation, Safety & Security Consortium (MDISS)

Medical Device Risk Assessment Platform (MDRAP™)

PFP Cybersecurity

Device Monitor

Ramparts

Risk Assessment

NIST SP 1800-8C: Securing Wireless Infusion Pumps

v

Technology Partner/Collaborator

Build Involvement

Smiths Medical

• Medfusion® 3500 Version 5 Syringe Infusion System • PharmGuard® Toolbox Version 1.5 • Medfusion 4000 Wireless Syringe Infusion Pump • PharmGuard Toolbox 2 Version 3.0 use with Medfusion 4000 and 3500 Version 6 (US)

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

• PharmGuard Server Licenses, PharmGuard Server Enterprise Edition Version 1.1 • CADD®-Solis Ambulatory Infusion Pump • CADD-Solis Medication Safety Software Symantec Corporation

• Symantec Endpoint Protection (SEP) • Advanced Threat Protection: Network (ATP:N) • Data Center Security: Server Advanced (DCS:SA)

TDi Technologies, Inc.

NIST SP 1800-8C: Securing Wireless Infusion Pumps

ConsoleWorks®

vi

Contents 1 Introduction ......................................................................................... 1

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

1.1

Practice Guide Structure ............................................................................................... 1

1.2

Typographical Conventions ........................................................................................... 2

1.3

How-To Overview .......................................................................................................... 3

1.4

Logical Architecture Summary ...................................................................................... 3

2 Product Installation Guides .................................................................. 4 2.1

2.2

2.3

2.4

2.5

The Core Network ......................................................................................................... 4 2.1.1

Cisco ASA Baseline Configuration .................................................................................4

2.1.2

External Firewall and Guest Network ...........................................................................5

2.1.3

Enterprise Services ........................................................................................................5

2.1.4

Biomedical Engineering Network..................................................................................5

2.1.5

Medical Devices ............................................................................................................6

2.1.6

Cisco Catalyst Switch Configuration..............................................................................6

2.1.7

Cisco Enterprise Wi-Fi Infrastructure ............................................................................7

2.1.8

TDi ConsoleWorks External Remote Access ...............................................................14

Infusion Pump and Pump Server ................................................................................. 25 2.2.1

Infusion Pumps ...........................................................................................................25

2.2.2

Infusion Pumps Server Systems ..................................................................................31

Identity Services .......................................................................................................... 32 2.3.1

Cisco Identity Service Engine ......................................................................................32

2.3.2

DigiCert Certificate Authority .....................................................................................38

Symantec Endpoint Protection and Intrusion Detection ............................................ 44 2.4.1

Symantec Data Center Security: Server Advanced .....................................................44

2.4.2

Symantec Endpoint Protection Manager ....................................................................49

2.4.3

Symantec Advanced Threat Protection: Network ......................................................50

Risk Assessment Tools ................................................................................................. 52 2.5.1

PFP Device Monitoring System: pMon 751 and P2Scan .............................................52

NIST SP 1800-8C: Securing Wireless Infusion Pumps

vii

2.5.2

Clearwater IRM|Analysis™ Software ..........................................................................61

2.5.3

MDISS MDRAP.............................................................................................................71

Appendix A

Baseline Configuration File ................................................ 81

A.1 Baseline Configuration File .......................................................................................... 81 A.2 External Firewall and Guest Network ASA Configuration File .................................... 84 A.3 Enterprise Services ASA Configuration File ................................................................. 93 This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

A.4 Biomedical Engineering ............................................................................................. 101 A.5 Medical Devices Zone ASA Configuration File........................................................... 110 A.6 Switch Configuration File .......................................................................................... 115 A.7 Wireless Configuration .............................................................................................. 122

Appendix B

Sample Pump Configuration Parameters......................... 246

Appendix C

Acronyms ........................................................................ 253

Appendix D

References ...................................................................... 256

NIST SP 1800-8C: Securing Wireless Infusion Pumps

viii

List of Figures Figure 1-1 Logical Architecture Summary ........................................................................................... 3 Figure 2-1 Importing Server Certificate ............................................................................................ 36 Figure 2-2 DCS:SA Environment ....................................................................................................... 45 Figure 2-3 PFP Monitoring System Reference Setup ......................................................................... 53 Figure 2-4 P2Scan Home Page.......................................................................................................... 54 This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

Figure 2-5 New Project Creation ...................................................................................................... 55 Figure 2-6 P2Scan Main Screen ........................................................................................................ 55 Figure 2-7 P2Scan Configuration Parameters .................................................................................... 56 Figure 2-8 Data Collection Screen During Capture ............................................................................ 57 Figure 2-9 Completed Baseline Extraction Screen ............................................................................. 58 Figure 2-10 Runtime Monitoring Showing the Execution of Four Different States.............................. 59 Figure 2-11 Runtime Monitoring Showing an Anomalous State ........................................................ 60 Figure 2-12 Sample Contents Saved in the Runtime Results File ........................................................ 61 Figure 2-13 IRM|Analysis Login Page ............................................................................................... 62 Figure 2-14 Asset Inventory List ....................................................................................................... 63 Figure 2-15 New Asset..................................................................................................................... 63 Figure 2-16 Media/Asset Groups ..................................................................................................... 64 Figure 2-17 Edit Media/Asset Group ................................................................................................ 65 Figure 2-18 Controls – Global/Media ............................................................................................... 66 Figure 2-19 Risk Questionnaire List .................................................................................................. 67 Figure 2-20 Risk Questionnaire Form (Part 1) ................................................................................... 67 Figure 2-21 Risk Questionnaire Form (Part 2) ................................................................................... 68 Figure 2-22 Risk Response List – Risk Registry .................................................................................. 69 Figure 2-23 Risk Treat and Evaluate Form ........................................................................................ 69 Figure 2-24 Dashboard Example ...................................................................................................... 70 Figure 2-25 Report Example ............................................................................................................ 71 Figure 2-26 MDRAP Login Page ........................................................................................................ 72 Figure 2-27 MDRAP Welcome Page.................................................................................................. 73

NIST SP 1800-8C: Securing Wireless Infusion Pumps

ix

Figure 2-28 Device Inventory List ..................................................................................................... 73 Figure 2-29 Add Device.................................................................................................................... 74 Figure 2-30 Edit Device .................................................................................................................... 75 Figure 2-31 Inventory Bulk Import ................................................................................................... 76 Figure 2-32 Device Inventory Template Sample ................................................................................ 76 Figure 2-33 Create Assessment (Part 1) ............................................................................................ 77 This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

Figure 2-34 Create Assessment (Part 2) ............................................................................................ 78 Figure 2-35 Assessment Step (Example 1) ........................................................................................ 78 Figure 2-36 Assessment Step (Example 2) ........................................................................................ 79 Figure 2-37 Assessment Result (Dashboard Example) ....................................................................... 79 Figure 2-38 Assessment Result (Report Example) ............................................................................. 80

List of Tables Table 2-1 Infusion Pump List............................................................................................................ 25 Table 2-2 Summary of Infusion Pump Configuration Methods .......................................................... 27 Table 2-3 Pump Servers Used in this Example Implementation ......................................................... 31

NIST SP 1800-8C: Securing Wireless Infusion Pumps

x

1 Introduction The following guides show information technology (IT) professionals and security engineers how we implemented this example solution. We cover all of the products employed in this reference design. We do not recreate the product manufacturers’ documentation, which is presumed to be widely available. Rather, these guides show how we incorporated the products together in our environment. Note: These are not comprehensive tutorials. There are many possible service and security configurations for these products that are out of scope for this reference design. This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

1.1 Practice Guide Structure This National Institute of Standards and Technology (NIST) Cybersecurity Practice Guide demonstrates a standards-based reference design and provides users with the information they need to replicate commercially available technologies that can help secure the wireless infusion pump ecosystem. This reference design is modular and can be deployed in whole or in parts. This guide contains three volumes: ▪

NIST Special Publication (SP) 1800-8a: Executive Summary

▪

NIST SP 1800-8b: Approach, Architecture, and Security Characteristics – what we built and why

▪

NIST SP 1800-8c: How-To Guides – instructions for building the example solution (you are here)

Depending on your role in your organization, you might use this guide in different ways: Business decision makers, including chief security and technology officers, will be interested in the Executive Summary (NIST SP 1800-8a), which describes the: ▪

challenges enterprises face in securing the wireless infusion pump ecosystem

▪

example solution built at the National Cybersecurity Center of Excellence (NCCoE)

▪

benefits of adopting the example solution

Technology or security program managers who are concerned with how to identify, understand, assess, and mitigate risk will be interested in NIST SP 1800-8b, which describes what we did and why. The following sections will be of particular interest: ▪

Section 4, Risk Assessment and Mitigation, describes the risk analysis we performed

▪

Section 4.3, Security Characteristics and Control Mapping, maps the security characteristics of this example solution to cybersecurity standards and best practices

You might share the Executive Summary, NIST SP 1800-8a, with your leadership team members to help them understand the importance of adopting standards-based, commercially available technologies that can help secure the wireless infusion pump ecosystem.

NIST SP 1800-8C: Securing Wireless Infusion Pumps

1

IT professionals who want to implement an approach like this will find the whole practice guide useful. You can use the How-To portion of the guide, NIST SP 1800-8c, to replicate all or parts of the build created in our lab. The How-To guide provides specific product installation, configuration, and integration instructions for implementing the example solution. We do not recreate the product manufacturers’ documentation, which is generally widely available. Rather, we show how we incorporated the products in our environment to create an example solution.

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

This guide assumes that IT professionals have experience implementing security products within the enterprise. While we have used a suite of commercial products to address this challenge, this guide does not endorse these particular products. Your organization can adopt this solution or one that adheres to these guidelines in whole, or you can use this guide as a starting point for tailoring and implementing parts of commercially available technologies that can help secure the wireless infusion pump ecosystem. Your organization’s security experts should identify the products that will best integrate with your existing tools and IT system infrastructure. We hope you will seek products that are congruent with applicable standards and best practices. In NIST SP 1800-8b, Section 4.4, Technologies, lists the products we used and maps them to the cybersecurity controls provided by this reference solution.

1.2 Typographical Conventions The following table presents typographic conventions used in this volume. Typeface/Symbol

Meaning

Example

Italics

filenames and pathnames references to documents that are not hyperlinks, new terms, and placeholders

For detailed definitions of terms, see the NCCoE Glossary.

Bold

names of menus, options, command buttons and fields

Choose File > Edit.

Monospace

command-line input, on-screen computer output, sample code examples, status codes

mkdir

Monospace Bold

command-line user input contrasted with computer output

service sshd start

blue text

link to other parts of the document, a web URL, or an email address

All publications from NIST’s National Cybersecurity Center of Excellence are available at https://nccoe.nist.gov.

NIST SP 1800-8C: Securing Wireless Infusion Pumps

2

1.3 How-To Overview Refer to NIST SP 1800-8b: Approach, Architecture, and Security Characteristics for an explanation of why we used each technology.

1.4 Logical Architecture Summary

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

Figure 1-1 depicts a reference network architecture that performs groupings that would translate to network segments or zones. The rationale behind segmentation and zoning is to limit trust between areas of the network. In considering a hospital infrastructure, NCCoE identified devices and usage, and grouped them by usage. The grouping facilitated the identification of network zones. Once zones are defined, infrastructure components may be configured such that those zones do not inherently have network access to other zones within the hospital network infrastructure. Segmenting the network in this fashion limits the overall attack surface posed to the infusion pump environment, and considers the network infrastructure configuration as part of an overall defense in depth strategy. Figure 1-1 Logical Architecture Summary

NIST SP 1800-8C: Securing Wireless Infusion Pumps

3

2 Product Installation Guides This section of the practice guide contains detailed instructions for installing and configuring all of the products used to build an instance of the example solution.

2.1 The Core Network

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

The NCCoE’s example architecture implements a core network zone, which is used to establish the backbone network infrastructure. The external firewall/router also has an interface connected to the core enterprise network, just like other firewall/router devices in the other zones. The core network zone serves as the backbone of the enterprise network and consists only of routers connected by switches. The routers automatically share internal route information with each other via authenticated Open Shortest Path First (OSPF) [1] to mitigate configuration errors as zones are added or removed. Several functional segments may be part of this core network: ▪

guest network

▪

business office (example only)

▪

database server (example only)

▪

enterprise services

▪

clinical services (example only)

▪

biomedical engineering

▪

medical devices with wireless LAN

▪

remote access for external vendor support

The NCCoE build uses Cisco Adaptive Security Appliances (ASA) as virtual router and firewall devices within the network. Each defined zone in the hospital network that we built has its own ASA, with two interfaces to protect each zone. As we considered how many ASAs to use, we opted for a tradeoff between the complexity of the configuration and the number of interfaces on a single ASA.

2.1.1 Cisco ASA Baseline Configuration In our environment, all ASAs are virtualized and are based on Cisco’s Adaptive Security Virtual Appliance (ASAv) product. In your environment, the responsible person would complete installation by following the Cisco Adaptive Security Virtual Appliance (ASAv) Quick Start Guide, 9.6 [2]. We imported the virtual appliance called asav-vi.ovf, assigning the first interface to the management network, the second interface to the wide area network (WAN), and the third interface to the local area network (LAN). For an unknown reason, the show version command did not work in the console; as a workaround, we configured Secure Shell (SSH) [3] access and ran the command via SSH instead.

NIST SP 1800-8C: Securing Wireless Infusion Pumps

4

Next, we configured the ASA with a baseline-configuration template that allows all outbound traffic, as well as only related inbound traffic as allowed by the stateful firewall. Internet Control Message Protocol (ICMP) [4] enables troubleshooting with ping and traceroute tools. Authenticated OSPF automated routing tables as we added or removed ASAs in the network. In your production environment, you may wish to make different decisions in your baseline configuration. All ASAs have an additional management interface on 192.168.29.0/24. We opted to configure Simple Network Management Protocol (SNMP) [5] and SSH for management use on this interface, but not on the other interfaces. See Section A.1 of Appendix A for the ASA configuration for this zone. This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

2.1.2 External Firewall and Guest Network We configured the build network to use network address translation (NAT) at the external firewall. This is the only point in the network where NAT is used. The upstream provider uses 10.0.0.0/8 addresses on the WAN interface. We also defined a LAN interface on 192.168.100.0/24 as the core network where other ASAs connect. Another interface is defined as GUEST on 192.168.170.0/24. We assigned the GUEST and LAN interfaces equal security levels, higher than those for the WAN interface. When ASA interfaces are configured with equal security levels, they, by default, cannot communicate with each other, but they will both have WAN access. Dynamic Host Configuration Protocol (DHCP) [6] is enabled on the GUEST interface for addressing. See Section A.2 of Appendix A for the ASA configuration for this zone.

2.1.3 Enterprise Services We defined a LAN interface on 192.168.120.0/24 as the LAN for all enterprise services. Ports are open for the domain name system (DNS) from the biomedical engineering network to the DNS servers. Port 8114 is open for all hosts to the Symantec Endpoint Protection (SEP) server. Several ports are open for any host to the Symantec Data Center Security: Server Advanced (DCS:SA). See Section A.3 of Appendix A for the ASA configuration for this zone.

2.1.4 Biomedical Engineering Network This zone contains a dedicated wireless network to support the wireless infusion pumps. We defined a LAN interface on 192.168.140.0/24 for all biomedical equipment, including infusion pump servers. Each manufacturer has a custom set of ports opened to their server. These ports are only accessible from the medical device network. Generally, the firewall is configured in this way: ▪

all pump servers > internet/intranet (all destinations)

▪

all intranet > all pump servers Ping and Traceroute (primarily for debugging)

▪

all pumps > Smiths Medical Pump Server on Port 1588

NIST SP 1800-8C: Securing Wireless Infusion Pumps

5

▪

all pumps > Carefusion Pump Server on Port 3613

▪

all pumps > Baxter Pump Server on Port 51244

▪

all pumps > Hospira Pump server on Ports 443, 8443, 8100, 9292, 11443, and 11444

▪

all pumps > B. Braun Pump server on Ports 443, 80, 8080, 1500, and 4080

See Section A.4 of Appendix A for the ASA configuration for this zone.

2.1.5 Medical Devices This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

We defined a LAN interface on 192.168.150.0/24 as the LAN for all medical devices. The infusion pump systems are designed such that all external connections to the pumps, such as an electronic health record (EHR) system or vendor maintenance, are completed with the associated pump server on the biomedical engineering network. This enables us to deny all outbound traffic not destined for the biomedical engineering network. In addition, because some pump servers initiate connections to open ports on the pumps, we added vendor-specific rules to allow this. A DNS server is not useful in this case; however, if you need one, we recommend that the ASA act as a forwarder. The DHCP server on the ASA is enabled for LAN addressing. In our lab, we discovered that at least one brand of infusion pump would not recognize network setup as complete, unless at least one DNS server address was set. In this case, the DNS server address only needed to be included in the configuration; a DNS server did not actually need to be present at that address. Generally, the firewall is configured in this way: ▪

all pumps > all pumps servers

▪

all intranet > all pumps Ping and Traceroute (primarily for debugging)

▪

Hospira Pump Server > all pumps on Ports 8100, 9292, 443, and 8443

▪

Baxter Pump Server > all pumps on Port 51243

▪

B. Braun Pump Server > all pumps on Ports 80, 443, 8080, and 1500

See Section A.5 of Appendix A for the ASA configuration for this zone.

2.1.6 Cisco Catalyst Switch Configuration The Catalyst 3650 switch is configured with four virtual local area networks (VLANs) [7]. One port is assigned to a management VLAN, with Subnet 192.168.20.0/24. Wireless access points (APs) are connected to a Wi-Fi management VLAN, which is also trunked back to the virtual wireless LAN controller (WLC) software. Additionally, the biomedical engineering network and the medical device network have some physical ports configured for testing, both of which are also trunked back to the virtualization hardware and ASAs. DHCP is enabled for the wireless APs. SNMP and SSH are enabled for management. The switch also supports Power over Ethernet (PoE), allowing for a single Ethernet cable, with both data and power for the APs.

NIST SP 1800-8C: Securing Wireless Infusion Pumps

6

To set up your organization’s configuration, follow the instructions in Cisco’s Catalyst 3650 Switch Getting Started Guide [8]. See Section A.6 of Appendix A for the switch configuration.

2.1.7 Cisco Enterprise Wi-Fi Infrastructure

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

The Wi-Fi management network is different, in that it does not have a firewall/router that connects directly to the core network. As a completely closed network, the Wi-Fi management network is used for management and communication between the Cisco Aironet wireless APs and the Cisco WLC. The WLC is the central point where wireless service set identifiers (SSIDs), VLANs, and Wi-Fi Protected Access II (WPA2) [9] security settings are managed for the entire enterprise. We defined two SSIDs: IP_Dev and IP_Dev_Cert. IP_Dev uses WPA2-PSK (Pre-Shared Key), and IP_Dev_Cert uses WPA2-Enterprise protocols.

2.1.7.1

Installation

In our environment, the Cisco WLC is virtualized. In your environment, the responsible person would complete installation by following Cisco’s Virtual Wireless LAN Controller Deployment Guide 8.2 [10]. We imported the virtual appliance called AIR_CTVM_K9_8_2_111_0.ova, assigning the first interface to the management network, referred to as service-port in the web interface. The second interface is used as a trunk port, with VLAN tags for all user and Wi-Fi management traffic. In the web interface, the builtin management interface refers to the wireless system control traffic network to which the APs are connected. The primary management mechanism for the WLC is the web interface. To configure an Internet Protocol (IP) address for the web interface, we first needed to use the console and complete the setup wizard that sets the service-port address. What follows is our process, which your organization can adapt to your needs.

2.1.7.2

Controller Configuration

Follow these steps to configure network interfaces: 1. Configure the interface for AP management traffic at Controller > Interfaces > Management.

NIST SP 1800-8C: Securing Wireless Infusion Pumps

7

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

2. Configure interfaces for user Wi-Fi traffic by first mapping the interface to an Ethernet port and setting the VLAN and IP address, and then mapping to wireless SSIDs. Create the new interface at Controller > Interfaces > New.

Configure the new interface by using the form shown below. Refer to the completed interface for the values that we used in the lab.

NIST SP 1800-8C: Securing Wireless Infusion Pumps

8

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

Our completed list of interfaces looks as shown below.

3. Configure the Network Time Protocol (NTP) server [11] at Controller > NTP > Server > New.

NIST SP 1800-8C: Securing Wireless Infusion Pumps

9

4. To configure the DHCP server, disable the DHCP Proxy at Controller > Advanced > DHCP. This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

2.1.7.3

Wireless AP Connection and Setup

Connect the APs to the Ethernet ports configured for untagged VLAN 1520. The APs will automatically obtain their addresses and the WLC address via DHCP from the switch (see Section 2.1.6). No other VLANs should to be configured for the APs because we are using a centralized switching model where Wi-Fi traffic VLANs are connected to the enterprise network through the WLC. As each AP is connected, it should show up in the Wireless tab on the WLC. For each AP, the AP Mode needs to be set to FlexConnect, as shown below.

2.1.7.4

Authentication Configuration

To use certificate-based authentication, the WLC must consult a remote authentication dial-in user service (RADIUS) server. Configure the Cisco Identity Services Engine (ISE) RADIUS server IP address and shared secret at Security > RADIUS > Authentication > New.

NIST SP 1800-8C: Securing Wireless Infusion Pumps

10

2.1.7.5

WLANs Configuration

At this point, we configured two SSIDs for medical devices: IP_Dev and IP_Dev_Cert. IP_Dev is configured for WPA2-PSK (Advanced Encryption Standard [AES] [12]), and IP_Dev_Cert is configured for WPA2-Enterprise (AES). Both SSIDs use the same interface, and therefore connect to the same network VLAN; the only difference is the Wi-Fi security. To create a new SSID, follow these steps: 1. Use the WLANS tab, select Create New from the dropdown list and click Go. This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

2. Enter your new SSID information.

3. In WLANs > WLANs > WLANs, select the WLAN identification (ID) number of the newly created SSID. For the Status, select the checkbox for Enabled. Set the Interface/Interface Group(G) to ip_dev.

NIST SP 1800-8C: Securing Wireless Infusion Pumps

11

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

4. On the Security tab, on the Layer 2 sub-tab, under Authentication Key Management, de-select the Enable checkbox for 802.1X, select the Enable checkbox for PSK, and set the PSK Format.

NIST SP 1800-8C: Securing Wireless Infusion Pumps

12

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

5. For the SSID IP_Dev_Cert, repeat Steps 1 through 4 above (replacing IP_Dev with IP_Dev_Cert in the instructions), but do not change the security settings for Authentication Key Management (leave 802.1X checked, and leave PSK unchecked). 6. On the Security tab, on the AAA Servers sub-tab, select the RADIUS server to authenticate with (Server 1).

2.1.7.6

Monitoring

By using Monitor > Clients, you will find the list of currently connected clients, to which SSID they are connected, and the username used to authenticate (Common Name from Certificate).

NIST SP 1800-8C: Securing Wireless Infusion Pumps

13

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

2.1.7.7

Final Configuration

See Section A.7 of Appendix A for the WLC configuration. You can access details about additional configuration options in the Cisco Wireless Controller Configuration Guide, Release 8.0 [13].

2.1.8 TDi ConsoleWorks External Remote Access The NCCoE lab implemented a VendorNet using TDi ConsoleWorks, which is a browser interface that enables healthcare delivery organizations (HDOs) to manage, monitor, and record activities from external vendors in the IT infrastructure.

2.1.8.1

System Environment

The NCCoE lab set up a fully updated (as of April 20, 2016) CentOS 7 operating system, with the following hardware specifications: ▪

8 gigabytes (GB) of random access memory (RAM)

▪

40 GB hard disk drive

▪

one network interface

2.1.8.2

Other Requirements

▪

ConsoleWorks install media (we built from a CD)

▪

ConsoleWorksSSL-<version>.rpm

▪

ConsoleWorks_gui_gateway-<version>.rpm

▪

ConsoleWorks license keys (TDI_Licenses.tar.gz)

▪

software installation command

▪

yum install uuid libbpng12 libvncserver

NIST SP 1800-8C: Securing Wireless Infusion Pumps

14

2.1.8.3

Installation

As Root: 1. Place ConsoleWorks media into the system. 2. mount /dev/sr0 /mnt/cdrom 3. mkdir /tmp/consoleworks 4. cp /mnt/cdrom/consolew.rpm /tmp/consoleworks/consolew.rpm This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

5. rpm -ivh /tmp/consoleworks/ConsoleWorksSSL-<version>.rpm 6. mkdir /tmp/consoleworkskeys/ 7. Copy ConsoleWorks keys to /tmp/consoleworkskeys/. cd /tmp/consoleworkskeys/ tar xzf TDI_Licenses.tar.gz cp /tmp/consoleworkskeys* /etc/TDI_licenses/ /opt/ConsoleWorks/bin/cw_add_invo

8. Accept the License Terms. 9. Press the Enter key to continue. 10. Name the instance of ConsoleWorks. 11. Press the Enter key to accept the default port (Port 5176). 12. Press the N key to deny syslog listening. 13. Press the Enter key to accept the parameters entered. 14. Press the Enter key to return to /opt/ConsoleWorks/bin/cw_add_invo. 15. rpm -ivh /tmp/consoleworks/ConsoleWorks_gui_gateway-version>.rpm 16. /opt/gui_gateway/install_local.sh 17. /opt/ConsoleWorks/bin/cw_start <invocation name created early> 18. service gui_gatewayd start

NIST SP 1800-8C: Securing Wireless Infusion Pumps

15

2.1.8.4

Usage

1. Open a browser, and navigate to https://<ConsoleWorksIP>:5176. 2. Log in with Username: console_manager, Password: Setup. 3. Change the default password. 4. Choose Register Now. This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

NCCoE chose ConsoleWorks to segregate and limit vendor access to our labs. Our data model groups consoles and graphical connections together into a tag. The tag is a collection of equipment to which you need to connect, although a vendor typically owns the equipment. This tag allows us to operate on a group of consoles and graphical connections. We group users from the same vendor into a profile that allows us to operate on the users. An Access Control Rule associates a profile with a tag and defines permissions for a particular component type (typically consoles or graphical connections).

2.1.8.5

Initial Configuration of Graphical Gateway

This section is only required for graphical connections, such as virtual network computing (VNC) and remote desktop protocol (RDP). Use the menu in the sidebar to access all instructions provided in Section 2.1.8.5 through Section 2.1.8.12. 1. Click Graphical > Gateways > Add. 2. Set the Name as LOCAL, set the Host as localhost, and set the Port as 5172. 3. Select the Enabled checkbox, and then click Save. 4. Verify that it works by clicking Test in the top-left corner.

NIST SP 1800-8C: Securing Wireless Infusion Pumps

16

2.1.8.6

Create One Tag for Each Vendor Company

1. Click Security > Tags > Add. 2. Set the Name (usually the company name). 3. Click Save.

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

2.1.8.7

Create One Profile for Each Vendor Company

1. Click Users > Profiles > Add. 2. Set the Name (usually the company name). 3. Click Save.

2.1.8.8

Establish Graphical Access Controls

Repeat this section for each vendor company. 1. Click Security > Access Control > Add. 2. Set the Name to [VENDOR_COMPANY_NAME]_GRAPHICAL. 3. Select the Enabled checkbox. 4. Set the Order.

NIST SP 1800-8C: Securing Wireless Infusion Pumps

17

5. Set the Allow or Deny field to ALLOW. 6. Set the Component Type to Graphical Connection. 7. Look under Profile Selection; you should see: on the Basic tab, Property Profile Equals [vendor company profile name] <join> the vendor company profile in the box on the right This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

8. Look under Resource Selection; you should see: on the Basic tab, Associated With a Tag that Property Tag Equals [vendor company tag name] <join>

matching graphical connections in the box on the right 9. Under Privileges, under Resource Level, select the following checkboxes: Aware View Connect

NIST SP 1800-8C: Securing Wireless Infusion Pumps

18

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

2.1.8.9

Console Access Controls

Repeat this section for each vendor company. 1. Click Security > Access Control > Add. 2. Set the Name to [VENDOR_COMPANY_NAME]_CONSOLE. 3. Select the Enabled checkbox. 4. Set the Order. 5. Set the Allow or Deny field to ALLOW. 6. Set the Component Type to Console. 7. Look under Profile Selection; you should see: on the Basic tab, Property Profile Equals [vendor company profile name] <join> the vendor company profile in the box on the right

NIST SP 1800-8C: Securing Wireless Infusion Pumps

19

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

8. Look under Resource Selection; you should see: on the Basic tab, Associated With a Tag that Property Tag Equals [vendor company tag name] <join>

matching consoles in the box on the right 9. Under Privileges, under Resource Level, select the following checkboxes: Aware View Connect

NIST SP 1800-8C: Securing Wireless Infusion Pumps

20

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

2.1.8.10 Users 1. Click Users > Add. 2. Set the Name (usually the company name). 3. Set the Description. 4. Set the Password, and then retype the password to confirm (Retype Password). 5. Fill in contact information (under Contact Info). 6. Set the profile to the one defined for this user’s company (under PROFILES). 7. Click Save.

NIST SP 1800-8C: Securing Wireless Infusion Pumps

21

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

2.1.8.11 Add an RDP Graphical Connection 1. Click Graphical > Add. 2. Set the Name for the device to which you are connecting. 3. Set the Type to RDP. 4. Set the Host for the device to which you are connecting. 5. Set the following Authentication fields: Username Password Domain (optional) 6. Add the Graphical Gateway named LOCAL (under GATEWAYS).

NIST SP 1800-8C: Securing Wireless Infusion Pumps

22

7. Add tags for all vendor companies that should have access (under TAGS). 8. Click Save.

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

2.1.8.12 Add an SSH Console Connection 1. Click Consoles > Add. 2. Set the Name for the device to which you are connecting. 3. Set the Connector to SSH with Password. 4. Set the Host IP for the device to which you are connecting, by doing the following: Set the Port to 22. Set the Username. Set the Password.

NIST SP 1800-8C: Securing Wireless Infusion Pumps

23

Retype the password (Retype Password). 5. Add tags for all vendor companies that should have access (under TAGS). 6. Click Save.

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8. NIST SP 1800-8C: Securing Wireless Infusion Pumps

24

2.2 Infusion Pump and Pump Server 2.2.1 Infusion Pumps Vendors collaborating with the NCCoE in this use case donated the pump products listed in Table 2-1. Table 2-1 Infusion Pump List

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

Vendor Name

Product Name

Product Type

Description

B. Braun

Space Station

Station for hosting individual pump

Provides centralized power and network connection for pumps stacked on the station

Infusomat® Space Large-Volume Infusion Pump

Wireless infusion pump

Designed for acutecare facilities for adults and children

Perfusor® Space Syringe Pump

Syringe infusion pump

Can be stacked in Space Station and uses Space Station for network communication

Baxter

Baxter Sigma Spectrum

Wireless infusion pump

Provides a largevolume infusion capability for patients

BD

Alaris Patient Care Unit (PCU) 8015

Infusion pump core system

Provides a common user interface for programming infusion, network connection, and monitoring modules. The Alaris 8015 PCU is the core of the Alaris system and provides a common user interface for programming infusion and monitoring modules.

Alaris Syringe 8110

Syringe infusion pump

Provides a syringe infusion capability for patients, and works with the Alaris PCU

NIST SP 1800-8C: Securing Wireless Infusion Pumps

25

Vendor Name

Hospira This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

Smiths Medical

2.2.1.1

Product Name

Product Type

Description

Alaris Pump 8100

Large-volume infusion pump

Provides a largevolume infusion capability for patients, and works with the Alaris PCU

Plum 360

Infusion system

Builds on the air management and secondary delivery features of Plum A+, while expanding its drug library and wireless capability to enable streamlined electronic medical record integration

Hospira PCA

PCA syringe infusion system

Complements the infusion pump to manage pain

Medfusion 4000

Syringe infusion pump

Delivers medication to patients in critical care units

CADD-Solis 2000

Ambulatory infusion pump

Delivers medication to patients in hospital, home care, and alternative care facilities

Infusion Pump Setup

In our example solution, we generalized the infusion-pump vendors’ products and systems as infusion pump devices, infusion pump servers, and infusion pump ecosystems. Our first goal was to connect each vendor’s infusion pump(s) to their corresponding pump server for performing the basic operational events, such as registering the devices to the server; pushing/installing the new drug library to the pumps; pushing/updating the new version of software to the pumps; and keeping the log of the pump usage. Each pump vendor has a basic setup that includes configuring the pump to connect to the network and the pump server wirelessly. We used WPA2 security with AES for encryption. In the case of WPA2-PSK mode, we assigned all infusion pumps the same access password for wireless network authentication. In the case of WPA2-Enterprise with Extensible Authentication Protocol – Transport Layer Security

NIST SP 1800-8C: Securing Wireless Infusion Pumps

26

(EAP-TLS) [14], we configured the pumps to use an individual certificate issued by DigiCert for wireless network authentication, using the Cisco ISE, the enterprise authentication server. Because each pump vendor has its own way of connecting, configuring, and setting up its pumps, we describe high-level steps in a generic way. Table 2-2 summarizes these key configuration steps. See Appendix B for the sample configuration files. Table 2-2 Summary of Infusion Pump Configuration Methods

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

Vendor Name

Infusion Pump Model

Configuration Tool

Connection Method

Baxter

Sigma Spectrum

• uses a PC with an Infrared Data Association (IrDA) interface to program multiple pumps with the same configuration

• uses the IrDA Serial Infrared

• edits the network configuration file (a simple text file) on a PC, and sends it via the IrDA to a pump B. Braun

• links to a PC under the IrDA Serial Infrared Link Management Protocol Version 1.1

Space Station

• connects a PC with the HiBaSeD service program to the Space Station by using a B. Braun interface cable for pump configuration setting

• uses a special B. Braun interface cable

Infusomat Space Large-Volume Infusion Pump

• connects a PC with the HiBaSeD service program to the Space Station by using a B. Braun interface cable for pump configuration setting

• uses a special B. Braun interface cable

NIST SP 1800-8C: Securing Wireless Infusion Pumps

27

Vendor Name

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

BD

Infusion Pump Model

Configuration Tool

Connection Method

Perfusor Space Syringe Pump

• connects a PC with the HiBaSeD service program to the Space Station by using a B. Braun interface cable for pump configuration setting

• uses a special B. Braun interface cable

Alaris 8015 PC

• uses a management system to do the configuration

• uses a series cable to connect the pump to a local computer

• is the core of the Alaris system and provides a common user interface for programming infusion and monitoring modules Hospira

Hospira PCA

• accesses Web Configuration Utility on the pump through a web browser using the local IP address of the pump

• uses the pump’s Ethernet jack to connect to a LAN or to interface with the host computer

Plum 360

• accesses Web Configuration Utility on the pump through a web browser using the local IP address of the pump

• uses the pump’s Ethernet jack to connect to a LAN or to interface with the host computer

NIST SP 1800-8C: Securing Wireless Infusion Pumps

28

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

Vendor Name

Infusion Pump Model

Configuration Tool

Connection Method

Smiths Medical

Medfusion 4000

• pushes a configuration text file to the pump by using the Telnet from a PC that is connected to the pump with the known IP address

• connects a PC to pump using micro Universal Serial Bus (USB)-USB cable

CADD-Solis 2000

• uses Smiths Medical Network Configuration Utility to update the pump’s configuration parameters

• connects a PC to the pump by using a micro USB-USB cable

2.2.1.2

Infusion Pump Configuration

Pre-Conditions: ▪

You have set up a wireless AP with the pre-shared password SSID.

▪

You have installed and configured infusion pump servers.

▪

You have made available the infusion pump configuration and the setup manual.

Post-Conditions: ▪

You have connected the infusion pumps to the AP.

▪

You have established the pump server to discover the pumps to the corresponding pump server.

NCCoE followed the pump vendors’ instructions to access to the pump in the maintenance/biomedical model. We configured the pump as follows: ▪

For wireless properties: •

enable wireless.

•

use DHCP.

•

set the SSID (IP_Dev or IP_Dev_Cert).

NIST SP 1800-8C: Securing Wireless Infusion Pumps

29

▪

▪

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

▪

2.2.1.3

For wireless security properties: •

set the Security Mode (WPA2-PSK or WPA2-Enterprise).

•

set the Encryption Protocol to AES/CCMP.

•

enter the PSK password or install a PKI certificate.

For pump server properties: •

set the Server IP/port.

•

set the Device Name or ID.

•

set the Device Type.

To verify connectivity for each infusion pump and the corresponding pump server: •

connect the pumps to the AP (IP_Dev with PSK, or IP_Dev_Cert with EAP-TLS).

•

confirm that the pump receives an IP address from the DHCP server from the AP.

•

confirm that the pump server can discover the pumps and can display the pump status, such as connected, in use, or offline.

Infusion Pump Hardening

Hardening may include the following actions: ▪

disabling unused or unnecessary communication ports and services

▪

changing manufacture default administrative passwords

▪

securing the remote APs, if there are any

▪

confirming that the firmware version is up-to-date

NIST SP 1800-8C: Securing Wireless Infusion Pumps

30

2.2.2 Infusion Pumps Server Systems The summary of the infusion pump server systems that are used in this example implementation is listed in Table 2-3 below. Table 2-3 Pump Servers Used in this Example Implementation

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

Vendor Name

Product Name

Operating Platform

Description

B. Braun

DoseTrac Infusion Management

Microsoft® Windows®

A drug library and infusion management system that provides real-time, infusion data reporting and analysis to add safety, efficiency, and value

Baxter

Care Everywhere Infusion Pump Management System

Microsoft Windows

Provides an interface capability to help the hospital biomedical engineering department effectively manage their infusion pump fleet. The drug library publishing module helps the hospital pharmacy effectively distribute and enforce medication safety rules.

BD

Alaris Systems Manager

Compatible with VMware® ESX® and VMware vSphere® environment

A virtual server platform that provides two-way wireless communication with Alaris PC units

Hospira

Hospira MedNet Server

Microsoft Windows

Manages drug libraries, firmware updates, and configurations of intravenous pumps

NIST SP 1800-8C: Securing Wireless Infusion Pumps

31

Vendor Name

Product Name

Operating Platform

Description

Manages drug libraries, firmware updates, and configurations of Hospira intravenous pumps for Smiths Medical Pumps NCCoE installed the pump servers in the network in the VLAN 1400. To do so, we prepared a virtual machine in the VMware with the operating system and network, as specified in the vendor installation manual. Because one or more database is associated with the infusion pump server for storing the data, the installation and configuration of the database are parts of the pump server installation procedure. After the installation, we implemented a basic configuration: the user account setup, reporting template configuration, security hardening, license installation, pump metadata installation. Smiths Medical

PharmGuard Server

Microsoft Windows

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

We have not included the pump server setup because the vendor performs this activity.

2.3 Identity Services 2.3.1 Cisco Identity Service Engine The Cisco ISE enables your organization to: ▪

centralize and unify identity and access policy management

▪

have visibility and more-assured device identification during certificate challenges

▪

use business rules to segment access to sections of the network

▪

make the user experience seamless during the challenge process, even with more-assured and stronger authentication

System requirements: ▪

Virtual Hypervisor (VH) capable of housing virtual machines (VMs)

▪

VM with Central Processing Unit (CPU): single quad core, 2.0 gigahertz (GHz) or faster

▪

VM with a minimum 4 GB RAM

▪

VM with a minimum 200 GB disk space

NCCoE installed the Cisco ISE 2.1 on a VM by using the Open Virtual Appliance (OVA) image provided by Cisco. For your organization, follow the guidance from your VM vendor to import the OVA and to start the install process. Once the system boots up, follow the console display to select one of the installation options. The configuration parameter selected for this use case is shown below. ! hostname

NIST SP 1800-8C: Securing Wireless Infusion Pumps

32

ise !ip domain-name nccoe.lab ! ipv6 enable !interface

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

GigabitEthernet 0 ip address 192.168.29.159 255.255.255.0 ipv6 address autoconfig ipv6 enable ! interface GigabitEthernet 1 ip address 192.168.120.159 255.255.255.0 ipv6 address autoconfig ipv6 enable !interface GigabitEthernet 2 shutdown ipv6 address autoconfig ipv6 enable ! interface GigabitEthernet 3 shutdown ipv6 address autoconfig ipv6 enable ! ip name-server 8.8.8.8 8.8.4.4 ! ip default-gateway 192.168.120.1 ! ! clock timezone EST ! ntp server time.nist.gov ! username [******] password [******] $5$jNPleEb4$YxDZH6oDF2Y4.02OqE/jBWxXFumRvtpe8JdNNZm1yj0 role admin ! max-ssh-sessions 5 ! service sshd enable ! password-policy lower-case-required

NIST SP 1800-8C: Securing Wireless Infusion Pumps

33

upper-case-required digit-required no-username no-previous-password password-expiration-enabled password-expiration-days 45 password-expiration-warning 30

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

min-password-length 4 password-lock-enabled password-lock-timeout 15 password-lock-retry-count 3 ! logging loglevel 6 ! conn-limit 10 port 9060 ! cdp timer 60 cdp holdtime 180 cdp run GigabitEthernet 0 ! icmp echo on !

2.3.1.1

Configure ISE to Support EAP-TLS Authentication

Execute your management of the Cisco ISE with a web browser, unless you intend to administer via command line. Using a web browser and the Cisco ISE host address, log into the Cisco ISE Administration Portal. You will use the credentials (username and password) that you created during the installation procedure.

2.3.1.2

Set ISE to Support RADIUS Authentication

Use the following steps to set up a communication connection from the Cisco ISE to the network device (AP) that you use as the authentication server during RADIUS [15] authentication: 1. Add a Network Resource. a. From the ISE Administration Portal, navigate to the following path: Administration > Network Resources > Network Devices. Select Add. Fill out the required parameters as indicated in the form:

NIST SP 1800-8C: Securing Wireless Infusion Pumps

34

i. the name of the network device ii. the IP Address of the device with its subnet mask 2. Select the RADIUS protocol as the selected protocol, and enter the shared secret that is configured on the network device.

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

3. Populate the system certificate with certificate-authority (CA)-signed certificates. We replaced the Cisco ISE default self-signed certificate with the CA-signed certificate issued through DigiCert Certificate Authority. The steps for acquiring the signing certificate from DigiCert are described in Section 2.3.2. 4. Once the CA-signed certificate for the ISE and the Root CA are issued, use the following steps to install the certificates to the system. 5. From the ISE Administration Portal, use the following navigation path to show the installed certificates: Administration > System > Certificates > System Certificates. Select Import to open a screen for importing a server certificate. Fill in the required information as shown in Figure 2-1.

NIST SP 1800-8C: Securing Wireless Infusion Pumps

35

Figure 2-1 Importing Server Certificate

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

6. Under Usage, select the EAP Authentication checkbox to enable the imported certificate to be used for EAP authentication. Next, click the Submit button to complete the certificate importing. 7. Import the DigiCert Root CA and signing CA to ISE Trusted Certificates. From the ISE Administration Portal, use the following navigation path to show the installed certificates: Administration > System > Certificates > Trusted Certificates. Select Import to open a screen for importing the DigiCert Root CA and signing the CA individually. After importing, make sure that the certificate status is Enabled. Establish the Online Certificate Status Protocol (OCSP) [16] client profile from the OCSP Client Profile page (Administration > System > Certificates > OCSP Client Profile). If OCSP is used for Certificate Status Validation, check Validate against the OCSP Service, and enter the OCSP service name.

NIST SP 1800-8C: Securing Wireless Infusion Pumps

36

8. Set the Identity Source for Client Certificate Authentication. When using the trusted certificate for EAP-TLS certificate-based authentication validation, set up the Certificate Authentication Profile in the ISE as the external identity source. Instead of authenticating via the traditional username and password, the Cisco ISE compares the client certificate received from the AP to verify the authenticity of a device—in this case, the infusion pump. a. Create a Certificate Authentication Profile:

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

i. Use the Administration Portal to navigate to the following path: Administration > Identity Management > External Identity Sources > Certificate Authentication Profile. Click Add. ii. Name the profile as, for example, Cert_Auth_Profile, and then fill out the form with proper parameters. Be sure to select Subject Name as the Principal Username X509 attribute because it is the field that will be used to validate the authenticity of the client. Select the Identity Resource Sequences tab. In the Certificate Based Authentication, select the Select Certificate Authentication Profile checkbox, and then choose Cert_Auth_Profile from the drop-down list. 9. Set Authentication Protocols. The Cisco ISE uses authentication protocols to communicate with external identity sources. The Cisco ISE supports many authentication protocols, such as the Password Authentication Protocol (PAP), Protected Extensible Authentication Protocol (PEAP), and the EAP-TLS. For this build, we used the EAP-TLS protocol for user and machine authentication. To specify the allowed protocols services in the Cisco ISE, follow these steps: From the Administration Portal, navigate to the following path: Policy > Policy Elements > Results > Authentication > Allowed Protocols > Add. Select the preferred protocol or list of protocols. In this build, the EAP_TLS is selected as the allowed authentication protocol. 10. Set up Authentication Policy. Define the authentication policy by selecting the protocols that the ISE should use to communicate with the network devices, and the identity sources that it should use for authentication. To specify the authentication policy, follow these steps: From the Administration Portal, navigate to the following path: Policy > Authentication Policy > Type > Rule Based. If Protocol is Wireless 802.1x, set the policy to use the Network Device as defined in Step 1 and the Identity Sequences as defined in Step 8 above.

NIST SP 1800-8C: Securing Wireless Infusion Pumps

37

2.3.2 DigiCert Certificate Authority DigiCert is a cloud-based platform designed to provide a full line of Secure Sockets Layer (SSL) certificates, tools, and platforms for optimal certificate life-cycle management. After you set up an account with DigiCert, you can use a DigiCert dashboard and its built-in certificate management tools to issue public key infrastructure (PKI) certificates for network authentication and encryption for data at rest or data in transition, if needed. The following instruction describes the process that we used to request a PKI certificate on behalf a wireless infusion pump using the DigiCert PKI services. This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

2.3.2.1

Create a Certificate Signing Request

A Certificate Signing Request (CSR) can be represented as a Base64 encoded PKCS#10 binary format. Many tools and utilities are available to help generate a CSR, and the key pair containing the private key and public key is generated at the same time. The CSR identifies the applicant’s distinguished name, which must be digitally signed using the applicant’s private key and the information for the public key chosen for the applicant. In this build, Certificate Utility for Windows (DigiCertUtil.exe) provided by DigiCert is used to generate CSRs for infusion pumps. Download and save the DigiCertUtil.exe from https://www.digicert.com/util/csr-creation-microsoftservers-using-digicert-utility.htm. 1. Double-click DigiCertUtil.exe to start the utility.

2. Click the Create CSR link to open a CSR request window.

NIST SP 1800-8C: Securing Wireless Infusion Pumps

38

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

3. On the Create CSR window, fill in the key information (some of the information is optional). Certificate Type:

Select SSL.

Common Name:

Enter the entity name.

Organization:

Enter your company’s legally registered name.

City:

Enter the city where your company is legally located.

State:

Select the state where your company is legally located.

Country:

Select the country where your company is legally located.

Key Size:

Select 2048.

Provider:

Select Microsoft RSA SChannel Cryptographic Provider (unless you have a specific cryptographic provider).

4. Click Generate to generate a CSR.

NIST SP 1800-8C: Securing Wireless Infusion Pumps

39

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

This will also generate a corresponding private key in the Windows computer from which the CSR is requested. The Certificate Enrollment Request is stored under Console Root\Certificates(Local Computer)\Certificate Enrollment Requests\Certificates.

2.3.2.2

Issue Signed Certificates

1. With a created applicant CSR, request a signed certificate using DigiCert CertCentral portal. Log into a DigiCert Dashboard (https://www.digicert.com/account/login.php) with your account username and password. Once in the portal, go to Request a Certificate, and then select Private SSL to open a certificate request form. Fill in the certificate settings in the fields shown in the form, which includes pasting the CSR information to the area called Paste your CSR. 2. After filling in all of the required information, scroll down to the bottom of the page, and select the I agree to the Certificate Services Agreement above checkbox. Next, click the Submit Certificate Request button at the bottom of the form to submit the certificate for signing approval. The administrator of the CA authority will use the same portal with different privileges

NIST SP 1800-8C: Securing Wireless Infusion Pumps

40

to approve the request after reviewing and verifying the submitted request information if needed. 3. To download the signed certificate, go to CERTIFICATES > Orders to list the ordered signed certificates.

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

4. Click a specific order number to display the certificate details with a list of actions for you to perform. Click Download Certificate As to download certificates with signed CA and Root CA certificates. A variety of certificate formats can be downloaded, such as .crt, .p7b, .pem, etc. 5. Save the downloaded certificate in a location where it can be used for further processing if needed.

2.3.2.3

Import and Export the Signed Certificate

Using DigiCert Utility and the OpenSSL tool, you can further manipulate the certificates to combine with the private key and export the signed certificate, or you can convert certificates or keys into the formats specified for your organization’s devices. 1. To import a signed certificate, use DigiCert Utility to click the Import button to load a downloaded file to the utility. The downloaded file was saved in Step 5 of Section 2.3.2.2. Click the Next button to import.

NIST SP 1800-8C: Securing Wireless Infusion Pumps

41

2. From the DigiCert Certificate Utility for Windows, click SSL to list all of the imported files.

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

3. To export the certificate, select the certificate that you want to export as a combined certificate file and key file in a .pfx file, or separated as a certificate file and key file, and then click Export Certificate.

NIST SP 1800-8C: Securing Wireless Infusion Pumps

42

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

4. Click the Next button, and then follow the wizard instructions to save the certificate file and private key file to a desired location.

NIST SP 1800-8C: Securing Wireless Infusion Pumps

43

2.3.2.4

Certificate and Key File Format Conversion

PKI certificates and key files can be in different formats. When PKI certificates are used in medical devices, device manufacturer user guides specify which formats are acceptable in their devices. Fortunately, many tools can perform format conversion. One utility tool that NCCoE used is the OpenSSL for Windows. It is an open-source tool and can be downloaded from https://www.openssl.org/community/binaries.html. Here are some of the useful convert commands: This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

▪

To convert a .crt file to a .pem file: •

▪

To convert a private key into .pem format: •

▪

openssl x509 -in mycert.crt -outform PEM -out mycert.pem

openssl rsa -in yourdomain.key -outform PEM -out yourdomain_pem.key

Separate a .pfx file into two different .key/.crt files: •

For a key file: openssl pkcs12 -in yourfile.pfx -nocerts -out keyfileencrypted.key

•

For a cert file: openssl pkcs12 -in [yourfile.pfx] -clcerts -nokeys -out [certificate.crt]

▪

To convert a certificate .pem file to a .der file: •

▪

openssl x509 -outform der -inform DEM -in certificate.pem -out certificate.der

To convert a key .pem file to a .der file: •

openssl rsa -inform DEM -in infile.key -out outfile.der-outform DER

2.4 Symantec Endpoint Protection and Intrusion Detection NCCoE protected the pump server application in the notional biomedical engineering network by using three Symantec cybersecurity products on an enterprise network, with a specific focus on wireless infusion pumps: 1. DCS:SA 2. SEP Manager Server 3. Advanced Threat Protection: Network (ATP:N) Each of these Symantec products protects components in the enterprise systems, at different levels.

2.4.1 Symantec Data Center Security: Server Advanced For data center security, DCS:SA provides a policy-based approach to endpoint security and compliance. DCS:SA includes the management server, the agents, the unified management console, the database,

NIST SP 1800-8C: Securing Wireless Infusion Pumps

44

and DCS Security Virtual Appliance (SVA). The agent components working with the server management provide intrusion prevention and detection on endpoint devices; the database is used for storing the policies, agent information, and real-time actionable events; and the SVA provides agentless antimalware protection for VMware guest VMs running Windows. The management server and the console can be installed on one system, and the agents are generally deployed to every supported host or endpoint device. Figure 2-2 displays the DCS:SA environment. Figure 2-2 DCS:SA Environment This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

2.4.1.1

Installing DCS:SA Manager

Minimum hardware requirements: ▪

hardware support x86, EM64T, and AMD64, with 60 GB free disk space (all platforms)

▪

8 GB RAM

▪

four CPUs

Minimum software requirements: ▪

Windows Installer 2.0 or higher

▪

Microsoft Structured Query Language (SQL) Server 2008

▪

.NET Framework 4.0 or 4.5.1

▪

PowerShell 2.0

▪

Windows 2008 or later

Operating the Symantec DCS:SA installation requires to link to an instance of SQL Server locally or remotely. All installations allocate approximately 60 GB of space for the database on SQL Server Enterprise edition. We first installed a new instance of SQL Server that conforms to the Symantec

NIST SP 1800-8C: Securing Wireless Infusion Pumps

45

installation requirements. The SQL Server was installed on the same machine as that for the DCS:SA Manager. Follow these steps to install the SQL Server software. 1. Use SCSP as the default instance name. 2. Set the authentication configuration to Mixed Mode (Windows authentication and SQL Server authentication). This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

3. Set the sa with a password when you set Mixed Mode authentication. You will need this password when you install Data Center. 4. After installing the instance of SQL Server, select to authenticate by using SQL Server credentials. 5. Register the instance. Registering the instance also starts the instance. Follow these steps to install DCS:SA: 1. Double-click server.exe. Next, in the Welcome panel, click Next, and accept the license agreement. 2. In the Installation Type panel, click Evaluation Installation, click Use an Existing MSSQL Instance, and then click Next. 3. Follow the instructions, and select the parameters suitable for your organization, to complete the installation. See the Symantec™ Data Center Security: Server, Monitoring Edition, and Server Advanced 6.7 MP1 Planning and Deployment Guide [17] for further details.

2.4.1.2

Configuration of DCS:SA Manager

After you install the Management Server, the Server Configuration Wizard lets you configure various parameters of the installation. One purpose of these configuration settings is to use the policy-based least-privilege access control provided by DCS to lock-down the configuration settings, files, and file systems in the pump for restricting application and operating system behavior and protecting the files and systems from tampering. To enable a policy in DCS Management Server, follow these steps: 1. Log into the DCS console. 2. Create a policy folder.

NIST SP 1800-8C: Securing Wireless Infusion Pumps

46

3. In the Java console, click Policies. 4. Under the Policies tab, click Prevention or Detection. 5. On the Policies page, in the Workspace Folders, select the Workspace folder, and then rightclick Add Folder. Look for a new policy folder with the name New Folder. Rename this folder as Pump Server. 6. Copy an existing policy to the Pump Server folder. This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

7. From the default Symantec folder, find a proper policy example, and copy it to the Pump Server folder. 8. In the Workspace pane, select a policy (e.g., “windows-baseline-detection” policy in Symantec folder for Detection), and then right-click Move To. In the MoveFolder dialog box, select Pump Server to receive the policy, and then click MoveTo. 9. To edit a policy, right-click a policy, and then click Edit Policy. Configure the setting based on your security protection needs. DCS:SA provides a variety of configurable protection from application data protection, to application protection, to network protection. For example, the Windows prevention policies have a Protected Whitelisting strategy that lets you specify an application to which you always want to allow access or give permission to run. When you whitelist a process or an application, all of the other processes and applications that are not included in the list are denied access. To allow a program to run by using the Protected Whitelisting strategy, follow these steps: 1. In the management console, click the Policies tab, and then click Prevention. 2. In the Policies workspace, click Add. 3. In the Select a Prevention Policy Builder wizard, in the New Policy Builder section, click Launch. 4. In the Policy Name panel, from the Policy Pack drop-down list, select the policy pack that you want to use as the baseline for the new custom policy. 5. In the Name textbox, enter a name for the policy that you create. In this build, we use the following name: Windows Prevention Policy 6.0 Reference 31 Protected Whitelisting strategy. 6. Select the Create a custom prevention policy checkbox, and then click Next. 7. In the Protection Strategy panel, use the slider to select Protected Whitelisting. 8. In the Trusted Updaters panel, click Add. In the Select Type dialog box, select the type of updater that you want to add. The Trusted Updaters list is populated through the agent data retriever. You can edit or delete an updater that you have already added to the list.

NIST SP 1800-8C: Securing Wireless Infusion Pumps

47

9. Click Next. 10. In the Application Rules panel, click Add. In the Select Type dialog box, select the type of rules that you want to add. You can edit or delete a rule that you have already added to the list. 11. In the Global Policy Options panel, click Configure to configure the global policy settings, and then click Next. 12. In the Summary panel, click Save. This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

2.4.1.3

Installing DCS:SA Agent

Use agent.exe to install the agent software on computers that run supported Windows operating systems. To install the Windows agent software, follow these steps: 1. On the installation package, double-click agent.exe. 2. In the Welcome panel, click Next. 3. In the License Agreement panel, select the I accept the terms in the license agreement checkbox, and then click Next. 4. In the Destination Folder panel, change the folders if necessary, and then click Next. 5. In the Agent Configuration panel, accept or change the default settings, and then click Next. Ensure that the Enable Intrusion Prevention checkbox is selected. 6. In the Management Server Configuration panel, in the Primary Management Server box, type the fully qualified host name or IP address of the primary server that is used to manage this agent. If you changed the Agent Port setting during management server installation, in the Agent Port box, type a port number that matches. 7. (Optional) In the Management Server Configuration panel, in the Alternate Management Servers box, type the fully qualified host name or IP address of the alternate servers that are used for failover for this agent. Type the servers in a comma-separated list. 8. In the Management Server Configuration panel, accept the directory for the SSL certificate Agent-cert.ssl, or click Browse to browse to and locate Agent-cert.ssl. Access to a copy of the SSL certificate Agent-cert.ssl is required to connect to the management server. All primary and alternate management servers must use the same certificate. 9. In the Management Server Configuration panel, click Next. 10. (Optional) In the Agent Group Configuration panel, in the group boxes, type the group names that you created with the Java console. You may add multiple detection policy group names

NIST SP 1800-8C: Securing Wireless Infusion Pumps

48

separated with commas. You may include the name of an existing detection policy domain in the group path/name. 11. In the Agent Group Configuration panel, click Next. 12. In the Service User Configuration panel, accept the default Local System account, and then click Next. 13. In the Ready to Install the Program panel, confirm the installation parameters, and then click Install. This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

14. When the installation completes, click Finish. Agent installation configures the appropriate networking for the environment. The agent installation configuration includes which Data Center Security: Server Advanced Management Servers to communicate with, which ports to use, and how often to poll for changes. The initial Data Center Security: Server Advanced installation also determines whether key product features are enabled or not. Particular key agent features can be installed, and each provides different protection: ▪

enabling the intrusion prevention feature

▪

enabling the real-time file integrity monitoring feature in intrusion detection

▪

creating agent registration groups

See the Symantec™ Data Center Security: Server, Monitoring Edition, and Server Advanced 6.7 MP1 Planning and Deployment Guide [17] for details.

2.4.2 Symantec Endpoint Protection Manager Minimum hardware requirements: ▪

2 GB RAM (minimum 8 GB or more recommended)

▪

40 GB hard drive (minimum, 200 GB recommended) for the management server and database with a remote SQL Server database

Minimum software requirements: ▪

Windows Installer 2.0 or higher

▪

Microsoft SQL Server 2008

▪

.NET Framework 4.0 or 4.5.1

▪

PowerShell 2.0

▪

Windows 2008 Server or later

Intel Pentium Dual-Core or equivalent (minimum, 8-core or greater recommended)

NIST SP 1800-8C: Securing Wireless Infusion Pumps

49

SEP Manager includes an embedded database. You may instead choose to use a database from one of the following versions of Microsoft SQL Server: SQL Server 2008, SP4 up to SQL Server 2016.

2.4.2.1

Installing SEP Manager

1. Download the product, and extract the entire installation file to a physical disk, such as a hard disk. Run Setup.exe. The installation should start automatically. 2. Follow the screen instructions, and accept the license agreement. This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

3. Continue the installation until it is finished. After the initial installation completes, configure the server and database. 4. Click Next. The Management Server Configuration Wizard starts. 5. Select Default Configuration, and then click Next. 6. Enter company name, a password for the default administrator admin, and an email address. 7. If you run LiveUpdate as part of a new installation, content is more readily available for the clients that you deploy. 8. If you want Symantec to receive anonymous data, click Next to begin the database creation. 9. When the database creation completes, click Finish to complete the SEP Manager configuration.

2.4.2.2

Installing the Client

After installing SEP Manager, install the SEP client to the endpoint host with the Client Deployment Wizard. Of the several installation methods, we recommend using the Save package. This installation option creates an executable installation package that you save on the management server and then distribute to the client computers. To install the SEP client, follow these steps: 1. Make your configuration selections as you install SEP Manager, and then create the client installation packages. 2. Save the installation package to a folder on the computer that runs SEP Manager. 3. Copy this package to a client machine where you have an administrator privilege. 4. The installation package comprises one setup.exe file. Click the executable file to start the installation. Follow the wizards to complete the installation.

2.4.3 Symantec Advanced Threat Protection: Network With ATP:N installed on the network, it can provide network-based protection of medical device subnets via monitor internal inbound and outbound internet traffic. Integrating Symantec ATP:N with SEP will

NIST SP 1800-8C: Securing Wireless Infusion Pumps

50

allow ATP:N to monitor and manage all network traffic from the endpoints and to provide threat assessment for dangerous activity to secure the medical devices on an enterprise network. Minimum hardware requirements: ▪

32 GB RAM

▪

four CPUs

▪

500 GB hard drive (minimum)

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

Minimum software requirements: ESXi 5.5 and 6.0, ATP:N virtual appliance includes an Integrated Dell Remote Access Controller (iDRAC). The iDRAC console requires the latest version of the Java Runtime Environment (JRE) installed on the administrative client.

2.4.3.1

ATP:N Installation

The installation of the ATP:N involves the deployment of the OVA template on the VMware ESXi Server. Sample installation steps are listed below. 1. Deploy the OVA. During the deploying procedure, the Deploy OVA Template wizard prompts you to map the Source Network adapters, which are built into the ATP:N OVA with Destination Networks that you already configured on your network. 2. In VMware vSphere Client, start the newly created virtual appliance. 3. Open a console to the appliance, and log on with the username admin and the proper password to start the bootstrap. 4. From a computer that is on the same subnet as the appliance management port, use a browser to connect to the ATP:N Manager using the ATP:N IP address. The username is setup, and the password is Symantec.

2.4.3.2

Integrating ATP:N with SEP

Integrating Symantec ATP:N with SEP allows for the correlation of event data from SEP Manager to ATP:N. To do the integration, follow these steps: 1. On SEP Manager, prepare the database for log collection to allow ATP:N to access the database using DB administrator (sa) credentials. 2. Enable the Symantec Endpoint Protection Correlation option by selecting the checkbox the Settings > Global > Synapse area of ATP:N Manager. 3. In ATP:N Manager, configure the connection to SEP Manager instances. 4. In SEP Manager, configure host integrity and quarantine firewall policies, if not already enabled. 5. In SEP Manager, configure endpoints to send information to the ATP:N management node.

NIST SP 1800-8C: Securing Wireless Infusion Pumps

51

6. In ATP:N Manager, add SSL certificates for secure communication between endpoints and ATP:N, if needed. More detail about integrating Symantec ATP:N and SEP can be found from the following reference: http://help.symantec.com/cs/ATP_2.2/ATP/v102658999_v117970559/About-integrating-ATP-withSymantec-Endpoint-Protection?locale=EN_US.

2.5 Risk Assessment Tools This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

2.5.1 PFP Device Monitoring System: pMon 751 and P2Scan The NCCoE lab deployed a PFP Monitoring System consisting of a pMon 751 appliance and the P2Scan analytics tool. The PFP system provides integrity assessment and intrusion detection by utilizing an external out-of-band channel (i.e., electromagnetic radiation or instantaneous power consumption), which are unintended emissions also known as side-channels. PFP takes fine-grained measurements of the device’s side-channels to identify unique patterns created by the specific logic execution. The pMon 751 appliance captures the side-channel signals by using a physical sensor, and sends them to P2Scan to be processed. The P2Scan analysis tool collects data during controlled execution and uses it to build a baseline of authorized execution during a tool training phase. Once tool training is completed, P2Scan continuously monitors the device for deviations from the baseline to determine whether unauthorized execution, such as a malicious intrusion, has occurred. Hardware requirements: ▪

pMon 751 data acquisition module

▪

Electromagnetic (EM) probe (Aaronia Magnetic Direction Finder [MDF])

▪

12 Volts Direct Current (VDC) Power Supply

▪

SMA (SubMiniature version A) cables to connect probe

▪

Secure Digital (SD) card

Host computer requirements: ▪

Operating system: Windows 10 Professional x64

▪

RAM: 16 GB or higher strongly recommended

▪

Hard drive: 1 GB of free space

▪

Ethernet connection

▪

hardware setup

NIST SP 1800-8C: Securing Wireless Infusion Pumps

52

The EM loop probe is sensitive to changes in the magnetic fields produced by the pump or the device under test (DUT). The intensity and signal structure of radiated magnetic fields from a device are typically spatially dependent. The probes must also be stationary during all tests, as P2Scan is highly sensitive in detecting changes in the radiated fields emitted from a device, which could alter data capture and analysis during the Data Collection and Baseline Extraction phases. A consistent EM probe placement using a cradle or harness is critical for the correct operation of the system. The reference setup of the PFP Monitoring System is shown in Figure 2-3. Figure 2-3 PFP Monitoring System Reference Setup This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

The following connections on the pMon 751 are required: ▪

12 to 24 Volt DC on Terminal 1 of power block

▪

GND on Terminal 2 of power block

▪

EM probe on the Signal input SMA connector

▪

connection to Ethernet network to reach host computer running P2Scan (By default, pMon is set with the static IP address 172.16.1.93.)

▪

(optional) trigger signal on the trigger input

NIST SP 1800-8C: Securing Wireless Infusion Pumps

53

2.5.1.1

P2Scan Setup

The P2Scan installer will install P2Scan as well as the required dependencies. Launch the setup.exe file from the installation media (typically USB drive). P2Scan uses a single project file to control the operation of P2Scan. As the user makes changes to the configuration parameters they will have the options to save the changes to the project file. The project file is in the .ini (initialization) file format. This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

2.5.1.2

Operating P2Scan

1. Launch P2Scan. This will open the application home page, where it allows you to create a new monitoring project or to load an existing project (Figure 2-4). Figure 2-4 P2Scan Home Page

a. To create a new project, click the New Project button on the home page (Figure 2-4). This will open the Create New Project window (Figure 2-5). You can change the Project Name (alters .ini name), the Project Template (select an .ini template to use), and the Project Root (creates a new directory to store the project). Once you have completed these fields, click Create Project.

NIST SP 1800-8C: Securing Wireless Infusion Pumps

54

Figure 2-5 New Project Creation

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

2. Once a project (new or existing) has been created, click Load Project on the home page (Figure 2-4). Navigate to the directory specified in Project Root, and select the .ini file that you created, which holds default values for guiding P2Scan. 3. Once the configuration file is loaded, P2Scan shows the main screen (Figure 2-6). The user should see the path of their project file in the Active Project File dialogue box. To select a different file, click the Change button. Figure 2-6 P2Scan Main Screen

NIST SP 1800-8C: Securing Wireless Infusion Pumps

55

4. Once the .ini file is selected, click Config to open the Configure Project screen with default parameters provided by the .ini file (Figure 2-7). The user can proceed to test their setup through pMon or modify the settings before entering the main program. For a detailed description of the different analysis parameters and their impact on the final result, please refer to the P2Scan User Manual. Figure 2-7 P2Scan Configuration Parameters

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8. NIST SP 1800-8C: Securing Wireless Infusion Pumps

56

2.5.1.3

Collection Process

The initial step in the PFP analysis process is to repetitively sample waveforms for each of the execution paths that are of interest to the user. These waveforms will ultimately form a bank of trusted references from which all unknown traces will be compared against to determine their validity during runtime monitoring. P2Scan interfaces with the pMon digitizing hardware. P2Scan provides a Capture interface (under Settings in Figure 2-8), which allows the user to configure the sampling parameters used by P2Scan. This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

This graphical user interface provides the user with the sampling parameters that may be adjusted for the collection system being used. Once the settings have been entered, click the Acquire Trace button to collect a sample trace and to view the results. The current data buffer will be displayed as shown in Figure 2-8, but will not be saved for analysis. After the capture parameters have been configured, select the Start Capture button to begin the data capture process. As data collection executes, the raw waveforms will be displayed on the screen, along with the percentage-complete indicator, as shown in Figure 2-8. Figure 2-8 Data Collection Screen During Capture

NIST SP 1800-8C: Securing Wireless Infusion Pumps

57

Data collection will enable a supervised tool training approach and will pause between run states. Each run state becomes a label during the tool training process. An example run state could be a specific configuration on the infusion pump or a specific version of firmware. The number of pause(s) is dependent on the number of paths in the capture settings prior to collecting data. Change to the next state, and click OK to continue collecting data. Repeat the process until Data Collection is 100% complete.

2.5.1.4

Baseline Extraction (Tool Training)

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

Once the data for all of the states has been collected, the next step is to train the system, for baseline extraction. The user has control over several analysis parameters during the Baseline Extraction phase. Several operational characteristics of the device being monitored can affect how to adjust the analysis parameter in order to achieve the desired results. For a detailed description of the different analysis parameters and their impact on the final system, please refer to the P2Scan User Manual. The baseline analysis is launched by pressing the Start button. The status window will be updated with the current status. Depending on the complexity of the DUT, and the processing power of the host machine, the baseline extraction may take time to run. After the Baseline Extraction phase has been completed, P2Scan will display the Percentage of correct Detection (PD) (Figure 2-9), which is calculated by comparing the sets of evaluation data to their respective baseline. The closer that the value is to 1, the better the ability of the system to discriminate that set of data. The detection statistics will be shown in the status bar, and, once complete, the user can click Launch Monitoring to enable runtime monitoring. Figure 2-9 Completed Baseline Extraction Screen

NIST SP 1800-8C: Securing Wireless Infusion Pumps

58

2.5.1.5

Runtime Monitoring

Once the necessary baselines have been calculated during tool training, P2Scan is able perform runtime monitoring of devices that have been previously characterized. The runtime monitor compares the test signals captured by the appliance, and compares them against the baselines. If the test device is executing one of the states used during training, P2Scan will classify the signal and provide a visual indication, using distinct colors to signify different device execution paths, as shown in Figure 2-10. The straight, thick black line signifies the threshold created from the Baseline Extraction phase. Figure 2-10 Runtime Monitoring Showing the Execution of Four Different States This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

If the software on the DUT changes to an unrecognized state, P2Scan will not be able to classify the test trace with the required confidence level, and will determine that an anomaly has occurred. In this case, P2Scan will show test results above the threshold, in a separate color from the successful states, as shown in Figure 2-11.

NIST SP 1800-8C: Securing Wireless Infusion Pumps

59

Figure 2-11 Runtime Monitoring Showing an Anomalous State

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

If the Save Data checkbox is selected (under Runtime), then the monitoring outputs shall be saved in a file in the directory specified by “Monitoring Output.” This file displays the date/time of the monitoring, and the TestStat, which shows statistical error distances between analyzed data and the DUT. Sample file output is shown in Figure 2-12. If desired, the monitoring outputs can be sent to a Security Information and Events Management (a SIEM tool) via syslog.

NIST SP 1800-8C: Securing Wireless Infusion Pumps

60

Figure 2-12 Sample Contents Saved in the Runtime Results File

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

2.5.2 Clearwater IRM|Analysis™ Software We used the Clearwater IRM|Analysis™ Software-as-a-Service (SaaS) application, a control-based risk tool for conducting a risk assessment focused on the HDO enterprise. In our environment, we built the enterprise network to simulate a typical HDO environment. Clearwater Compliance created an account for NCCoE under their cloud-based tool IRM|Analysis. The software is based on the construct of an “Information Asset” that creates, maintains, receives, or transmits electronic Protected Health Information (ePHI.) This can be a software application, information system, medical device system, etc. This section does not show you how to conduct a risk assessment. Instead, we present some basic steps for using the IRM|Analysis tool to conduct the risk assessment: 1. Log into IRM|Analysis. 2. Import Inventory of Information Assets, or enter the data through the Asset Inventory Form. 3. Establish conformance with the NIST-based Security Controls. 4. Determine the Risk Rating of the likelihood and impact. 5. Identify those risks that exceed the established Risk Threshold.

NIST SP 1800-8C: Securing Wireless Infusion Pumps

61

6. Document the Risk Response and associated tasks necessary to mitigate, transfer, avoid, or accept the risk in the IRM|Analysis software. 7. Leverage Dashboard and Reporting functionality to provide documentation and evidence of a credible and bona fide risk analysis.

2.5.2.1

Login to IRM|Analysis

1. Open a browser, and navigate to https://software.clearwatercompliance.com/login. This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

2. On the login page (Figure 2-13), enter the appropriate Email Address and Password. 3. Click the Sign In button. Figure 2-13 IRM|Analysis Login Page

2.5.2.2

Enter Asset Inventory

We used the New Asset page to add the assets to the system, and the Edit Asset page to update the record. After all assets are entered, an analysis is conducted to determine if media (i.e., devices) associated with different assets can be grouped together based on a similar risk profile. For instance, all servers are VMs using the same Storage Area Network and identical operating systems. If 10 assets are similarly configured using the same server, then the 10 assets can be grouped and evaluated as one asset. The Media/Asset Group is the logic group for organizing media into classes to reduce the number of identical security control assessments. Follow these steps to add a new asset: 1. On the IRM|Analysis tool, expand Assets on the left menu bar. 2. Under Assets, click Asset Inventory List. 3. On the Asset Inventory List page (Figure 2-14), click the New button.

NIST SP 1800-8C: Securing Wireless Infusion Pumps

62

4. On the New Asset form (Figure 2-15), enter the required information, and then click Save. Figure 2-14 Asset Inventory List

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

Figure 2-15 New Asset

NIST SP 1800-8C: Securing Wireless Infusion Pumps

63

Follow these steps to update an asset: 1. On the IRM|Analysis tool, expand Assets on the left menu bar. 2. Under Assets, click Asset Inventory List. 3. On the Asset Inventory List page (Figure 2-14), select the asset that you want to edit by clicking the checkbox next to that asset, and then click Edit.

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

4. On the Edit Media/Asset Groups page (see Figure 2-17 below), enter the necessary information, and then click Save. Follow these steps to view and manage media/asset groups: 1. On the IRM|Analysis tool, expand Assets on the left menu bar. 2. Under Assets, click Media/Asset Groups. 3. On the Media/Asset Groups page (Figure 2-16), scroll up and down to view the groups, and edit a group by clicking the Edit button next to that group. 4. On the Edit Media/Asset Groups page (Figure 2-17), enter the necessary information, and then click Save. Figure 2-16 Media/Asset Groups

NIST SP 1800-8C: Securing Wireless Infusion Pumps

64

Figure 2-17 Edit Media/Asset Group

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

2.5.2.3

Risk Determination

The IRM|Analysis tool uses different methods to determine risk. In this section, we show two ways to use the tool: the Controls – Global/Media screen to document the status of a control; and the Risk Questionnaire List to select a given Media/Asset Group. Follow these steps to use the Risk Determination at the Global/Media level: 1. On the IRM|Analysis tool, expand Risk Determination on the left menu bar. 2. Under Risk Determination, click Controls – Global/Media. 3. On the Controls – Global/Media page (Figure 2-18), scroll up and down to view the controls. For each control, select one of the responses (i.e., Yes, In Progress, No, or N/A) to indicate the response status.

NIST SP 1800-8C: Securing Wireless Infusion Pumps

65

Figure 2-18 Controls – Global/Media

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

Follow these steps to use the Risk Determination at the Media/Asset Group level: 1. On the IRM|Analysis tool, expand Risk Determination on the left menu bar. 2. Under Risk Determination, click Risk Questionnaire List. 3. On the Risk Questionnaire List page (Figure 2-19), scroll up and down to view the media/asset groups. 4. For each relevant Media/Asset Group, select the Risk Analyst, fill in the Due Date, and then click the Continue button to access the Risk Questionnaire Form (Part 1: Figure 2-20, and Part 2: Figure 2-21). 5. For each control, select one of the responses (i.e., Yes, In Progress, No, or N/A) to indicate the response status (example shown in Part 1: Figure 2-20), if it was already noted on the Controls – Global/Media page. 6. Controls can be set globally or for individual Media/Asset Groups. The plus sign (+) will expand the control to reveal the Media/Asset Groups so that the control can be set individually. To illustrate, a global control can be set for Training for the Security Workforce, but an individual control would be set for each of the Media/Asset Groups associated with the User Activity Review, as only a subset of assets may undergo a user activity review. 7. Determine and select the Risk Likelihood and Risk Impact for the selected risk scenario (example shown in Part 2: Figure 2-21) to populate the Risk Rating.

NIST SP 1800-8C: Securing Wireless Infusion Pumps

66

8. You may select the question mark (?) for more information on the control, and the NIST button for a quick reference to NIST SP 800-53: Security and Privacy Controls for Federal Information Systems and Organizations. Figure 2-19 Risk Questionnaire List

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

Figure 2-20 Risk Questionnaire Form (Part 1)

NIST SP 1800-8C: Securing Wireless Infusion Pumps

67

Figure 2-21 Risk Questionnaire Form (Part 2)

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

2.5.2.4

Risk Response

The IRM|Analysis tool enables users to try different methods of reviewing risk scenarios, acquiring a risk rating, and seeing progress in a risk response workflow. This section provides the basics of using the tool. Consider following these risk response steps: 1. In the IRM|Analysis tool, expand Risk Response in the left menu bar. 2. Under Risk Response, click Risk Response List. 3. Only the risks that exceed the risk threshold established under Framing/Governance (in the left menu bar) will move to the Risk Response portion of the software. 4. On the Risk Response List – Risk Registry page (Figure 2-22), scroll up and down to view the Medial/Asset Groups, along with the associated Threat Source/Event, Vulnerability, and Risk Rating. 5. For each relevant risk response, click the associated button in the Treatment column to access the Risk Treat and Evaluate Form page of that risk (Figure 2-23). 6. On the Risk Treat and Evaluate Form page (Figure 2-23), perform the risk response analysis by selecting the Risk Treatment Type; evaluate the control or recommendation; Select a Risk Owner; enter Risk Notes; etc.

NIST SP 1800-8C: Securing Wireless Infusion Pumps

68

Figure 2-22 Risk Response List – Risk Registry

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

Figure 2-23 Risk Treat and Evaluate Form

NIST SP 1800-8C: Securing Wireless Infusion Pumps

69

2.5.2.5

Dashboard and Report

The IRM|Analysis tool enables users to review their risk analyses with a dashboard or report format. To access the dashboard views, follow these steps: 1. On the IRM|Analysis tool, expand Dashboard on the left menu bar. 2. Under Dashboard, click Rating Distribution By Asset. 3. See the example dashboard on the Rating Distribution By Asset page shown in Figure 2-24. This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

You can also view other types of dashboards, such as Risk Rating Trends and Risk Rating Averages. Figure 2-24 Dashboard Example

For report views, follow these steps: 1. On the IRM|Analysis tool, expand Reports on the left menu bar. 2. Under Reports, click Risk Rating Report. 3. See the example report on the Risk Rating Report page shown in Figure 2-25. You can also view other types of dashboards, such as Risk Rating Trends and Risk Rating Averages.

NIST SP 1800-8C: Securing Wireless Infusion Pumps

70

Figure 2-25 Report Example

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

2.5.3 MDISS MDRAP We used the Medical Device Innovation, Safety & Security Consortium’s (MDISS’s) cloud-based Medical Device Risk Assessment Platform (MDRAP), a questionnaire-based risk assessment tool, to conduct the assessment on the medical devices. In our environment, we set up and configured wireless infusion pump systems from five manufactures, and built the enterprise network to simulate a typical HDO environment. Please note that this section does not show you how to conduct a risk assessment. Instead, we show these basic steps for using the MDRAP tool: ▪

login to MDRAP

▪

conduct device inventory

▪

risk assessment

▪

dashboard and reports

2.5.3.1

Login to MDRAP

1. Within a browser, type https://mdrap.mdiss.org/,and then click Log In. 2. On the login page (Figure 2-26), enter the appropriate Email and Password. 3. Click Submit.

NIST SP 1800-8C: Securing Wireless Infusion Pumps

71

Figure 2-26 MDRAP Login Page

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

2.5.3.2

Conduct Device Inventory

We use the Device Inventory module of MDRAP to keep track of all of the infusion pumps and servers in our sample implementation. Add Device enables us to add individual devices, while Bulk Import enables us to add a group of devices. Steps for using both methods follow. 1. On the Welcome to MDRAP page (Figure 2-27), click Device Inventory on the menu bar, or click the View Device Inventory link on the page. 2. On the Device Inventory page (Figure 2-28), add an individual device, edit a device, or bulk import a group of devices.

NIST SP 1800-8C: Securing Wireless Infusion Pumps

72

Figure 2-27 MDRAP Welcome Page

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

Figure 2-28 Device Inventory List

To add a device: i. On the Device Inventory page (see Figure 2-28 above), click ADD DEVICE.

NIST SP 1800-8C: Securing Wireless Infusion Pumps

73

ii. On the Add Device page (Figure 2-29), locate the device from the category list, and then click ADD. Figure 2-29 Add Device

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

To edit a device: i. On the Device Inventory page (see Figure 2-28 above), locate the device from the list, and then click the product name link or the edit icon. ii. On the Edit Inventory page (Figure 2-30), update the data, and then click Save.

NIST SP 1800-8C: Securing Wireless Infusion Pumps

74

Figure 2-30 Edit Device

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

To bulk import a group of devices: i. On the Device Inventory page (Figure 2-28 above), click the BULK IMPORT button. ii. On the Inventory Bulk Import page (Figure 2-31), download the template, and then fill-in the data into the template. iii. Follow the instruction to upload and import the devices by using the template (Figure 2-32).

NIST SP 1800-8C: Securing Wireless Infusion Pumps

75

Figure 2-31 Inventory Bulk Import

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

Figure 2-32 Device Inventory Template Sample

2.5.3.3

Risk Assessment

We created a risk assessment for each device by responding to the MDRAP’s built-in questionnaire. The basic steps of creating a risk assessment for a given device are listed below. 1. On the Welcome to MDRAP page (Figure 2-27 above), click Assessments on the menu bar, or click the Go to Assessments link on the page. 2. On the Create Assessment page (Part 1: Figure 2-33), select a device. 3. On the Create Assessment page (Part 2: Figure 2-34), select the questionnaire type (i.e., MDISS Questionnaire).

NIST SP 1800-8C: Securing Wireless Infusion Pumps

76

4. Answer the questions, and then click Next (see example questionnaire pages in Figure 2-35 and Figure 2-36). Figure 2-33 Create Assessment (Part 1)

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8. NIST SP 1800-8C: Securing Wireless Infusion Pumps

77

Figure 2-34 Create Assessment (Part 2)

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

Figure 2-35 Assessment Step (Example 1)

NIST SP 1800-8C: Securing Wireless Infusion Pumps

78

Figure 2-36 Assessment Step (Example 2)

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

2.5.3.4

Dashboard and Reports

MDRAP computes assessment results based on the responses to the questionnaires. For a given assessment (complete or partially complete), the assessment result is available for view as a dashboard (Figure 2-37) or report (Figure 2-38). Figure 2-37 Assessment Result (Dashboard Example)

NIST SP 1800-8C: Securing Wireless Infusion Pumps

79

Figure 2-38 Assessment Result (Report Example)

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8. NIST SP 1800-8C: Securing Wireless Infusion Pumps

80

Appendix A

Baseline Configuration File

A.1 Baseline Configuration File ASA Version 9.6(1) ! interface Management0/0 ip address 192.168.29.149 255.255.255.0

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

! ! optional, SSH, version is important as v1 is insecure and on by default, also set your own password! username [********] password [******] aaa authentication ssh console LOCAL ! set to network and interface you want to manage from, can be WAN ssh 192.168.29.0 255.255.255.0 management ssh version 2 ! hostname internal-kmcfadde ! ! Configure network interfaces interface GigabitEthernet0/0 nameif WAN security-level 50 ip address 192.168.100.149 255.255.255.0 no shutdown ! optional, authenticated OSPF for excellence ospf authentication-key [L}N]@Uv ospf authentication message-digest ! interface GigabitEthernet0/1 nameif LAN security-level 100 ip address 192.168.150.1 255.255.255.0

NIST SP 1800-8C: Securing Wireless Infusion Pumps

81

no shutdown ! ! optional, DHCP Server dhcpd address 192.168.150.220-192.168.150.250 LAN dhcpd dns 8.8.8.8 8.8.4.4 dhcpd option 3 ip 192.168.150.1 dhcpd enable LAN

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

! ! optional, OSPFv2 router ospf 1 network 192.168.100.0 255.255.255.0 area 0 redistribute connected subnets redistribute static subnets ! ! Configure DNS resolution here, required for license activation dns domain-lookup WAN dns server-group DefaultDNS name-server 8.8.8.8 name-server 8.8.4.4 ! license smart feature tier standard throughput level 1G names ! ! optional, Configure time zone and NTP here clock timezone EST -5 clock summer-time EDT recurring ntp server 10.97.74.8 ! ! Allow ping through LAN to WAN policy-map global_policy

NIST SP 1800-8C: Securing Wireless Infusion Pumps

82

class inspection_default inspect icmp inspect icmp error ! ! Show up in traceroute policy-map global_policy class class-default

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

set connection decrement-ttl ! ! Make ICMP/UDP traceroute work from LAN to WAN object-group icmp-type PING-REPLIES icmp-object echo-reply object-group icmp-type TRACEROUTE-REPLIES icmp-object time-exceeded icmp-object unreachable group-object PING-REPLIES access-list 101 extended permit icmp any any object-group TRACEROUTE-REPLIES access-list 101 extended permit icmp any any object-group PING-REPLIES ! ! Allow ICMP ping/traceroute from WAN to LAN object-group icmp-type PING icmp-object echo access-list 101 extended permit icmp any any object-group PING ! ! Allow UDP traceroute from WAN to LAN object-group service TRACEROUTEUDP service-object udp destination gt 33434 access-list 101 extended permit object-group TRACEROUTEUDP any any ! ! example, allow a specific port on a host ! access-list 101 extended permit tcp any host 192.168.140.XXX eq www !

NIST SP 1800-8C: Securing Wireless Infusion Pumps

83

! Add firewall rules we created to WAN interface access-group 101 in interface WAN ! ! Example, set a static route ! route WAN 192.168.140.0 255.255.255.0 192.168.100.111 ! ! SNMP

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

object network SNMPHOSTS subnet 192.168.29.0 255.255.255.0 snmp-server enable snmp-server community public snmp-server host-group management SNMPHOSTS

A.2 External Firewall and Guest Network ASA Configuration File : Saved : : Serial Number: 9AK64JT2D2M : Hardware:

ASAv, 2048 MB RAM, CPU Xeon E5 series 2200 MHz

: ASA Version 9.6(1) ! hostname border-kmcfadde enable password [******] encrypted xlate per-session deny tcp any4 any4 xlate per-session deny tcp any4 any6 xlate per-session deny tcp any6 any4 xlate per-session deny tcp any6 any6 xlate per-session deny udp any4 any4 eq domain xlate per-session deny udp any4 any6 eq domain xlate per-session deny udp any6 any4 eq domain xlate per-session deny udp any6 any6 eq domain !

NIST SP 1800-8C: Securing Wireless Infusion Pumps

84

license smart feature tier standard throughput level 1G names

! interface GigabitEthernet0/0

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

nameif WAN security-level 0 ip address 10.32.3.10 255.255.255.0 ! interface GigabitEthernet0/1 nameif LAN security-level 100 ip address 192.168.100.101 255.255.255.0 ospf authentication-key ***** ospf authentication message-digest ! interface GigabitEthernet0/2 nameif GUEST security-level 100 ip address 192.168.170.1 255.255.255.0 ! interface GigabitEthernet0/3 shutdown no nameif no security-level no ip address ! interface GigabitEthernet0/4 shutdown no nameif

NIST SP 1800-8C: Securing Wireless Infusion Pumps

85

no security-level no ip address ! interface GigabitEthernet0/5 shutdown no nameif no security-level

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

no ip address ! interface GigabitEthernet0/6 shutdown no nameif no security-level no ip address ! interface GigabitEthernet0/7 shutdown no nameif no security-level no ip address ! interface GigabitEthernet0/8 shutdown no nameif no security-level no ip address ! interface Management0/0 management-only nameif management security-level 0 ip address 192.168.29.147 255.255.255.0

NIST SP 1800-8C: Securing Wireless Infusion Pumps

86

! ftp mode passive clock timezone EST -5 clock summer-time EDT recurring dns domain-lookup WAN dns server-group DefaultDNS name-server 8.8.8.8

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

name-server 8.8.4.4 object network LAN-SUBNETS subnet 192.168.0.0 255.255.0.0 object network SNMPHOSTS subnet 192.168.29.0 255.255.255.0 object-group icmp-type PING-REPLIES icmp-object echo-reply object-group icmp-type TRACEROUTE-REPLIES icmp-object time-exceeded icmp-object unreachable group-object PING-REPLIES object-group icmp-type PING icmp-object echo object-group service TRACEROUTEUDP service-object udp destination gt 33434 access-list 101 extended permit icmp any any object-group TRACEROUTE-REPLIES pager lines 23 mtu WAN 1500 mtu LAN 1500 mtu management 1500 mtu GUEST 1500 no failover no monitor-interface service-module icmp unreachable rate-limit 1 burst-size 1 no asdm history enable

NIST SP 1800-8C: Securing Wireless Infusion Pumps

87

arp timeout 14400 no arp permit-nonconnected ! object network LAN-SUBNETS nat (LAN,WAN) dynamic interface access-group 101 in interface WAN !

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

route-map DEFAULT permit 10 match interface WAN

! router ospf 1 network 192.168.100.0 255.255.255.0 area 0 log-adj-changes redistribute connected subnets redistribute static subnets default-information originate ! route WAN 0.0.0.0 0.0.0.0 10.32.3.1 1 timeout xlate 3:00:00 timeout pat-xlate 0:00:30 timeout conn 1:00:00 half-closed 0:10:00 udp 0:02:00 sctp 0:02:00 icmp 0:00:02 timeout sunrpc 0:10:00 h323 0:05:00 h225 1:00:00 mgcp 0:05:00 mgcp-pat 0:05:00 timeout sip 0:30:00 sip_media 0:02:00 sip-invite 0:03:00 sip-disconnect 0:02:00 timeout sip-provisional-media 0:02:00 uauth 0:05:00 absolute timeout tcp-proxy-reassembly 0:01:00 timeout floating-conn 0:00:00 user-identity default-domain LOCAL aaa authentication ssh console LOCAL snmp-server host-group management SNMPHOSTS poll community ***** no snmp-server location no snmp-server contact

NIST SP 1800-8C: Securing Wireless Infusion Pumps

88

snmp-server community ***** crypto ipsec security-association pmtu-aging infinite crypto ca trustpoint _SmartCallHome_ServerCA no validation-usage crl configure crypto ca trustpool policy auto-import

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

crypto ca certificate chain _SmartCallHome_ServerCA certificate ca 6ecc7aa5a7032009b8cebcf4e952d491 308205ec 308204d4 a0030201 0202106e cc7aa5a7 032009b8 cebcf4e9 52d49130 0d06092a 864886f7 0d010105 05003081 ca310b30 09060355 04061302 55533117 30150603 55040a13 0e566572 69536967 6e2c2049 6e632e31 1f301d06 0355040b 13165665 72695369 676e2054 72757374 204e6574 776f726b 313a3038 06035504 0b133128 63292032 30303620 56657269 5369676e 2c20496e 632e202d 20466f72 20617574 686f7269 7a656420 75736520 6f6e6c79 31453043 06035504 03133c56 65726953 69676e20 436c6173 73203320 5075626c 69632050 72696d61 72792043 65727469 66696361 74696f6e 20417574 686f7269 7479202d 20473530 1e170d31 30303230 38303030 3030305a 170d3230 30323037 32333539 35395a30 81b5310b 30090603 55040613 02555331 17301506 0355040a 130e5665 72695369 676e2c20 496e632e 311f301d 06035504 0b131656 65726953 69676e20 54727573 74204e65 74776f72 6b313b30 39060355 040b1332 5465726d 73206f66 20757365 20617420 68747470 733a2f2f 7777772e 76657269 7369676e 2e636f6d 2f727061 20286329 3130312f 302d0603 55040313 26566572 69536967 6e20436c 61737320 33205365 63757265 20536572 76657220 4341202d 20473330 82012230 0d06092a 864886f7 0d010101 05000382 010f0030 82010a02 82010100 b187841f c20c45f5 bcab2597 a7ada23e 9cbaf6c1 39b88bca c2ac56c6 e5bb658e 444f4dce 6fed094a d4af4e10 9c688b2e 957b899b 13cae234 34c1f35b f3497b62 83488174 d188786c 0253f9bc 7f432657 5833833b 330a17b0 d04e9124 ad867d64 12dc744a 34a11d0a ea961d0b 15fca34b 3bce6388 d0f82d0c 948610ca b69a3dca eb379c00 48358629 5078e845 63cd1941 4ff595ec 7b98d4c4 71b350be 28b38fa0 b9539cf5 ca2c23a9 fd1406e8 18b49ae8 3c6e81fd e4cd3536 b351d369 ec12ba56 6e6f9b57 c58b14e7 0ec79ced 4a546ac9 4dc5bf11 b1ae1c67 81cb4455 33997f24 9b3f5345 7f861af3 3cfa6d7f

NIST SP 1800-8C: Securing Wireless Infusion Pumps

89

81f5b84a d3f58537 1cb5a6d0 09e4187b 384efa0f 02030100 01a38201 df308201 db303406 082b0601 05050701 01042830 26302406 082b0601 05050730 01861868 7474703a 2f2f6f63 73702e76 65726973 69676e2e 636f6d30 12060355 1d130101 ff040830 060101ff 02010030 70060355 1d200469 30673065 060b6086 480186f8 45010717 03305630 2806082b 06010505 07020116 1c687474 70733a2f 2f777777 2e766572 69736967 6e2e636f 6d2f6370 73302a06 082b0601 05050702 02301e1a 1c687474 70733a2f 2f777777 2e766572 69736967 6e2e636f 6d2f7270 61303406

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

03551d1f 042d302b 3029a027 a0258623 68747470 3a2f2f63 726c2e76 65726973 69676e2e 636f6d2f 70636133 2d67352e 63726c30 0e060355 1d0f0101 ff040403 02010630 6d06082b 06010505 07010c04 61305fa1 5da05b30 59305730 55160969 6d616765 2f676966 3021301f 30070605 2b0e0302 1a04148f e5d31a86 ac8d8e6b c3cf806a d448182c 7b192e30 25162368 7474703a 2f2f6c6f 676f2e76 65726973 69676e2e 636f6d2f 76736c6f 676f2e67 69663028 0603551d 11042130 1fa41d30 1b311930 17060355 04031310 56657269 5369676e 4d504b49 2d322d36 301d0603 551d0e04 1604140d 445c1653 44c1827e 1d20ab25 f40163d8 be79a530 1f060355 1d230418 30168014 7fd365a7 c2ddecbb f03009f3 4339fa02 af333133 300d0609 2a864886 f70d0101 05050003 82010100 0c8324ef ddc30cd9 589cfe36 b6eb8a80 4bd1a3f7 9df3cc53 ef829ea3 a1e697c1 589d756c e01d1b4c fad1c12d 05c0ea6e b2227055 d9203340 3307c265 83fa8f43 379bea0e 9a6c70ee f69c803b d937f47a 6decd018 7d494aca 99c71928 a2bed877 24f78526 866d8705 404167d1 273aeddc 481d22cd 0b0b8bbc f4b17bfd b499a8e9 762ae11a 2d876e74 d388dd1e 22c6df16 b62b8214 0a945cf2 50ecafce ff62370d ad65d306 4153ed02 14c8b558 28a1ace0 5becb37f 954afb03 c8ad26db e6667812 4ad99f42 fbe198e6 42839b8f 8f6724e8 6119b5dd cdb50b26 058ec36e c4c875b8 46cfe218 065ea9ae a8819a47 16de0c28 6c2527b9 deb78458 c61f381e a4c4cb66 quit telnet timeout 5 ssh stricthostkeycheck ssh 192.168.29.0 255.255.255.0 management ssh timeout 5 ssh version 2 console timeout 0

NIST SP 1800-8C: Securing Wireless Infusion Pumps

90

dhcpd dns 8.8.8.8 8.8.4.4 dhcpd option 3 ip 192.168.170.1 ! dhcpd address 192.168.170.220-192.168.170.250 GUEST dhcpd enable GUEST ! dynamic-access-policy-record DfltAccessPolicy

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

username [******] password [******] encrypted ! class-map inspection_default match default-inspection-traffic ! ! policy-map type inspect dns migrated_dns_map_1 parameters message-length maximum client auto message-length maximum 512 policy-map global_policy class inspection_default inspect dns migrated_dns_map_1 inspect ftp inspect h323 h225 inspect h323 ras inspect ip-options inspect netbios inspect rsh inspect rtsp inspect skinny inspect esmtp inspect sqlnet inspect sunrpc inspect tftp

NIST SP 1800-8C: Securing Wireless Infusion Pumps

91

inspect sip inspect xdmcp inspect icmp inspect icmp error class class-default set connection decrement-ttl !

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

service-policy global_policy global prompt hostname context no call-home reporting anonymous call-home profile CiscoTAC-1 no active destination address http https://tools.cisco.com/its/service/oddce/services/DDCEService destination address email callhome@cisco.com destination transport-method http subscribe-to-alert-group diagnostic subscribe-to-alert-group environment subscribe-to-alert-group inventory periodic monthly subscribe-to-alert-group configuration periodic monthly subscribe-to-alert-group telemetry periodic daily profile License destination address http https://tools.cisco.com/its/service/oddce/services/DDCEService destination transport-method http Cryptochecksum:9ffa4947d875e0c501e036c54e80ee93 : end

NIST SP 1800-8C: Securing Wireless Infusion Pumps

92

A.3 Enterprise Services ASA Configuration File : Saved : : Serial Number: 9AEHKLC171M : Hardware:

ASAv, 2048 MB RAM, CPU Xeon E5 series 2200 MHz

: ASA Version 9.6(1)

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

! hostname enterprise-services-kmcfadde enable password [******] encrypted xlate per-session deny tcp any4 any4 xlate per-session deny tcp any4 any6 xlate per-session deny tcp any6 any4 xlate per-session deny tcp any6 any6 xlate per-session deny udp any4 any4 eq domain xlate per-session deny udp any4 any6 eq domain xlate per-session deny udp any6 any4 eq domain xlate per-session deny udp any6 any6 eq domain ! license smart feature tier standard throughput level 1G names ! interface GigabitEthernet0/0 nameif WAN security-level 50 ip address 192.168.100.154 255.255.255.0 ospf authentication-key ***** ospf authentication message-digest !

NIST SP 1800-8C: Securing Wireless Infusion Pumps

93

interface GigabitEthernet0/1 nameif LAN security-level 100 ip address 192.168.120.1 255.255.255.0 ! interface GigabitEthernet0/2 shutdown

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

no nameif no security-level no ip address ! interface GigabitEthernet0/3 shutdown no nameif no security-level no ip address ! interface GigabitEthernet0/4 shutdown no nameif no security-level no ip address ! interface GigabitEthernet0/5 shutdown no nameif no security-level no ip address ! interface GigabitEthernet0/6 shutdown no nameif

NIST SP 1800-8C: Securing Wireless Infusion Pumps

94

no security-level no ip address ! interface GigabitEthernet0/7 shutdown no nameif no security-level

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

no ip address ! interface GigabitEthernet0/8 shutdown no nameif no security-level no ip address ! interface Management0/0 management-only nameif management security-level 0 ip address 192.168.29.154 255.255.255.0 ! ftp mode passive clock timezone EST -5 clock summer-time EDT recurring dns domain-lookup WAN dns server-group DefaultDNS name-server 8.8.8.8 name-server 8.8.4.4 object network SNMPHOSTS subnet 192.168.29.0 255.255.255.0 object-group service DNS service-object tcp-udp destination eq domain

NIST SP 1800-8C: Securing Wireless Infusion Pumps

95

object-group service SYMANTEC-DCS service-object tcp destination eq 4443 service-object tcp destination eq https service-object tcp destination eq 8443 service-object tcp destination eq 2222 access-list 101 extended permit icmp any any time-exceeded access-list 101 extended permit icmp any any unreachable

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

access-list 101 extended permit icmp any any echo-reply access-list 101 extended permit icmp any any echo access-list 101 extended permit udp any any gt 33434 access-list 101 extended permit object-group DNS 192.168.140.0 255.255.255.0 host 192.168.120.162 access-list 101 extended permit object-group DNS 192.168.140.0 255.255.255.0 host 192.168.120.163 access-list 101 extended permit tcp any host 192.168.120.166 eq 8114 access-list 101 extended permit object-group SYMANTEC-DCS any host 192.168.120.167 pager lines 23 mtu management 1500 mtu WAN 1500 mtu LAN 1500 no failover icmp unreachable rate-limit 1 burst-size 1 no asdm history enable arp timeout 14400 no arp permit-nonconnected access-group 101 in interface WAN router ospf 1 network 192.168.100.0 255.255.255.0 area 0 log-adj-changes redistribute connected subnets redistribute static subnets !

NIST SP 1800-8C: Securing Wireless Infusion Pumps

96

timeout xlate 3:00:00 timeout pat-xlate 0:00:30 timeout conn 1:00:00 half-closed 0:10:00 udp 0:02:00 sctp 0:02:00 icmp 0:00:02 timeout sunrpc 0:10:00 h323 0:05:00 h225 1:00:00 mgcp 0:05:00 mgcp-pat 0:05:00 timeout sip 0:30:00 sip_media 0:02:00 sip-invite 0:03:00 sip-disconnect 0:02:00 timeout sip-provisional-media 0:02:00 uauth 0:05:00 absolute timeout tcp-proxy-reassembly 0:01:00

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

timeout floating-conn 0:00:00 user-identity default-domain LOCAL aaa authentication ssh console LOCAL snmp-server host-group management SNMPHOSTS poll community ***** no snmp-server location no snmp-server contact snmp-server community ***** crypto ipsec security-association pmtu-aging infinite crypto ca trustpoint _SmartCallHome_ServerCA no validation-usage crl configure crypto ca trustpool policy auto-import crypto ca certificate chain _SmartCallHome_ServerCA certificate ca 6ecc7aa5a7032009b8cebcf4e952d491 308205ec 308204d4 a0030201 0202106e cc7aa5a7 032009b8 cebcf4e9 52d49130 0d06092a 864886f7 0d010105 05003081 ca310b30 09060355 04061302 55533117 30150603 55040a13 0e566572 69536967 6e2c2049 6e632e31 1f301d06 0355040b 13165665 72695369 676e2054 72757374 204e6574 776f726b 313a3038 06035504 0b133128 63292032 30303620 56657269 5369676e 2c20496e 632e202d 20466f72 20617574 686f7269 7a656420 75736520 6f6e6c79 31453043 06035504 03133c56 65726953 69676e20 436c6173 73203320 5075626c 69632050 72696d61 72792043 65727469 66696361 74696f6e 20417574 686f7269 7479202d 20473530 1e170d31 30303230 38303030 3030305a 170d3230 30323037 32333539 35395a30 81b5310b 30090603 55040613 02555331 17301506 0355040a 130e5665 72695369 676e2c20

NIST SP 1800-8C: Securing Wireless Infusion Pumps

97

496e632e 311f301d 06035504 0b131656 65726953 69676e20 54727573 74204e65 74776f72 6b313b30 39060355 040b1332 5465726d 73206f66 20757365 20617420 68747470 733a2f2f 7777772e 76657269 7369676e 2e636f6d 2f727061 20286329 3130312f 302d0603 55040313 26566572 69536967 6e20436c 61737320 33205365 63757265 20536572 76657220 4341202d 20473330 82012230 0d06092a 864886f7 0d010101 05000382 010f0030 82010a02 82010100 b187841f c20c45f5 bcab2597 a7ada23e 9cbaf6c1 39b88bca c2ac56c6 e5bb658e 444f4dce 6fed094a d4af4e10

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

9c688b2e 957b899b 13cae234 34c1f35b f3497b62 83488174 d188786c 0253f9bc 7f432657 5833833b 330a17b0 d04e9124 ad867d64 12dc744a 34a11d0a ea961d0b 15fca34b 3bce6388 d0f82d0c 948610ca b69a3dca eb379c00 48358629 5078e845 63cd1941 4ff595ec 7b98d4c4 71b350be 28b38fa0 b9539cf5 ca2c23a9 fd1406e8 18b49ae8 3c6e81fd e4cd3536 b351d369 ec12ba56 6e6f9b57 c58b14e7 0ec79ced 4a546ac9 4dc5bf11 b1ae1c67 81cb4455 33997f24 9b3f5345 7f861af3 3cfa6d7f 81f5b84a d3f58537 1cb5a6d0 09e4187b 384efa0f 02030100 01a38201 df308201 db303406 082b0601 05050701 01042830 26302406 082b0601 05050730 01861868 7474703a 2f2f6f63 73702e76 65726973 69676e2e 636f6d30 12060355 1d130101 ff040830 060101ff 02010030 70060355 1d200469 30673065 060b6086 480186f8 45010717 03305630 2806082b 06010505 07020116 1c687474 70733a2f 2f777777 2e766572 69736967 6e2e636f 6d2f6370 73302a06 082b0601 05050702 02301e1a 1c687474 70733a2f 2f777777 2e766572 69736967 6e2e636f 6d2f7270 61303406 03551d1f 042d302b 3029a027 a0258623 68747470 3a2f2f63 726c2e76 65726973 69676e2e 636f6d2f 70636133 2d67352e 63726c30 0e060355 1d0f0101 ff040403 02010630 6d06082b 06010505 07010c04 61305fa1 5da05b30 59305730 55160969 6d616765 2f676966 3021301f 30070605 2b0e0302 1a04148f e5d31a86 ac8d8e6b c3cf806a d448182c 7b192e30 25162368 7474703a 2f2f6c6f 676f2e76 65726973 69676e2e 636f6d2f 76736c6f 676f2e67 69663028 0603551d 11042130 1fa41d30 1b311930 17060355 04031310 56657269 5369676e 4d504b49 2d322d36 301d0603 551d0e04 1604140d 445c1653 44c1827e 1d20ab25 f40163d8 be79a530 1f060355 1d230418 30168014 7fd365a7 c2ddecbb f03009f3 4339fa02 af333133 300d0609 2a864886 f70d0101 05050003 82010100 0c8324ef ddc30cd9 589cfe36 b6eb8a80 4bd1a3f7 9df3cc53 ef829ea3 a1e697c1 589d756c e01d1b4c fad1c12d 05c0ea6e b2227055 d9203340 3307c265 83fa8f43 379bea0e 9a6c70ee f69c803b d937f47a

NIST SP 1800-8C: Securing Wireless Infusion Pumps

98

6decd018 7d494aca 99c71928 a2bed877 24f78526 866d8705 404167d1 273aeddc 481d22cd 0b0b8bbc f4b17bfd b499a8e9 762ae11a 2d876e74 d388dd1e 22c6df16 b62b8214 0a945cf2 50ecafce ff62370d ad65d306 4153ed02 14c8b558 28a1ace0 5becb37f 954afb03 c8ad26db e6667812 4ad99f42 fbe198e6 42839b8f 8f6724e8 6119b5dd cdb50b26 058ec36e c4c875b8 46cfe218 065ea9ae a8819a47 16de0c28 6c2527b9 deb78458 c61f381e a4c4cb66 quit

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

telnet timeout 5 ssh stricthostkeycheck ssh 192.168.29.0 255.255.255.0 management ssh timeout 5 ssh version 2 console timeout 0 dynamic-access-policy-record DfltAccessPolicy username [******] password [******] encrypted ! class-map inspection_default match default-inspection-traffic ! ! policy-map type inspect dns migrated_dns_map_1 parameters message-length maximum client auto message-length maximum 512 policy-map global_policy class inspection_default inspect dns migrated_dns_map_1 inspect ftp inspect h323 h225 inspect h323 ras inspect ip-options inspect netbios

NIST SP 1800-8C: Securing Wireless Infusion Pumps

99

inspect rsh inspect rtsp inspect skinny inspect esmtp inspect sqlnet inspect sunrpc inspect tftp

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

inspect sip inspect xdmcp inspect icmp inspect icmp error class class-default set connection decrement-ttl ! service-policy global_policy global prompt hostname context no call-home reporting anonymous call-home profile License destination address http https://tools.cisco.com/its/service/oddce/services/DDCEService destination transport-method http profile CiscoTAC-1 no active destination address http https://tools.cisco.com/its/service/oddce/services/DDCEService destination address email callhome@cisco.com destination transport-method http subscribe-to-alert-group diagnostic subscribe-to-alert-group environment subscribe-to-alert-group inventory periodic monthly subscribe-to-alert-group configuration periodic monthly

NIST SP 1800-8C: Securing Wireless Infusion Pumps

100

subscribe-to-alert-group telemetry periodic daily Cryptochecksum:e57e00145eb4fd26d97b4b0109308140 : end

A.4 Biomedical Engineering : Saved :

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

: Serial Number: 9A3RHJVFPQS : Hardware:

ASAv, 2048 MB RAM, CPU Xeon E5 series 2200 MHz

: ASA Version 9.6(1) ! hostname biomedical-kmcfadde enable password [******] encrypted xlate per-session deny tcp any4 any4 xlate per-session deny tcp any4 any6 xlate per-session deny tcp any6 any4 xlate per-session deny tcp any6 any6 xlate per-session deny udp any4 any4 eq domain xlate per-session deny udp any4 any6 eq domain xlate per-session deny udp any6 any4 eq domain xlate per-session deny udp any6 any6 eq domain ! license smart feature tier standard throughput level 1G names ! interface GigabitEthernet0/0 nameif WAN security-level 50 ip address 192.168.100.152 255.255.255.0

NIST SP 1800-8C: Securing Wireless Infusion Pumps

101

ospf authentication-key ***** ospf authentication message-digest ! interface GigabitEthernet0/1 nameif LAN security-level 100 ip address 192.168.140.1 255.255.255.0

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

! interface GigabitEthernet0/2 shutdown no nameif no security-level no ip address ! interface GigabitEthernet0/3 shutdown no nameif no security-level no ip address ! interface GigabitEthernet0/4 shutdown no nameif no security-level no ip address ! interface GigabitEthernet0/5 shutdown no nameif no security-level no ip address !

NIST SP 1800-8C: Securing Wireless Infusion Pumps

102

interface GigabitEthernet0/6 shutdown no nameif no security-level no ip address ! interface GigabitEthernet0/7

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

shutdown no nameif no security-level no ip address ! interface GigabitEthernet0/8 shutdown no nameif no security-level no ip address ! interface Management0/0 management-only nameif management security-level 0 ip address 192.168.29.152 255.255.255.0 ! ftp mode passive clock timezone EST -5 clock summer-time EDT recurring dns domain-lookup WAN dns server-group DefaultDNS name-server 8.8.8.8 name-server 8.8.4.4 object network SNMPHOSTS

NIST SP 1800-8C: Securing Wireless Infusion Pumps

103

subnet 192.168.29.0 255.255.255.0 object network PUMPS subnet 192.168.150.0 255.255.255.0 object-group icmp-type PING-REPLIES icmp-object echo-reply object-group icmp-type TRACEROUTE-REPLIES icmp-object time-exceeded

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

icmp-object unreachable group-object PING-REPLIES object-group icmp-type PING icmp-object echo object-group service TRACEROUTEUDP service-object udp destination gt 33434 object-group service BAXTERPORTS service-object tcp-udp destination eq 51244 object-group service SMITHSPORTS service-object tcp destination eq 1588 object-group service CAREFUSIONPORTS service-object tcp destination eq 3613 object-group service PCAPORTS service-object tcp destination eq https service-object tcp destination eq 11443 service-object tcp destination eq 11444 object-group service PLUM360PORTS service-object tcp destination eq 8100 service-object tcp destination eq 9292 object-group service HOSPIRAPUMPSIMPORTS service-object tcp destination eq https service-object tcp destination eq 8443 object-group service BBRAUNPORTS service-object tcp destination eq www service-object tcp destination eq https

NIST SP 1800-8C: Securing Wireless Infusion Pumps

104

service-object tcp destination eq 8080 service-object tcp destination eq 1500 service-object tcp destination eq 4080 access-list 101 extended permit icmp any any object-group TRACEROUTE-REPLIES access-list 101 extended permit object-group TRACEROUTEUDP any any access-list 101 extended permit icmp any any object-group PING access-list 101 extended permit icmp any any object-group PING-REPLIES

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

access-list 101 extended permit object-group SMITHSPORTS object PUMPS host 192.168.140.150 access-list 101 extended permit object-group CAREFUSIONPORTS object PUMPS host 192.168.140.158 access-list 101 extended permit object-group PCAPORTS object PUMPS host 192.168.140.160 access-list 101 extended permit object-group PLUM360PORTS object PUMPS host 192.168.140.160 access-list 101 extended permit object-group HOSPIRAPUMPSIMPORTS object PUMPS host 192.168.140.160 access-list 101 extended permit object-group BAXTERPORTS object PUMPS host 192.168.140.165 access-list 101 extended permit object-group BBRAUNPORTS object PUMPS host 192.168.140.169 pager lines 23 mtu WAN 1500 mtu LAN 1500 mtu management 1500 no failover no monitor-interface service-module icmp unreachable rate-limit 1 burst-size 1 no asdm history enable arp timeout 14400 no arp permit-nonconnected access-group 101 in interface WAN router ospf 1 network 192.168.100.0 255.255.255.0 area 0 log-adj-changes

NIST SP 1800-8C: Securing Wireless Infusion Pumps

105

redistribute connected subnets redistribute static subnets ! timeout xlate 3:00:00 timeout pat-xlate 0:00:30 timeout conn 1:00:00 half-closed 0:10:00 udp 0:02:00 sctp 0:02:00 icmp 0:00:02 timeout sunrpc 0:10:00 h323 0:05:00 h225 1:00:00 mgcp 0:05:00 mgcp-pat 0:05:00

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

timeout sip 0:30:00 sip_media 0:02:00 sip-invite 0:03:00 sip-disconnect 0:02:00 timeout sip-provisional-media 0:02:00 uauth 0:05:00 absolute timeout tcp-proxy-reassembly 0:01:00 timeout floating-conn 0:00:00 user-identity default-domain LOCAL aaa authentication ssh console LOCAL snmp-server host-group management SNMPHOSTS poll community ***** no snmp-server location no snmp-server contact snmp-server community ***** crypto ipsec security-association pmtu-aging infinite crypto ca trustpoint _SmartCallHome_ServerCA no validation-usage crl configure crypto ca trustpool policy auto-import crypto ca certificate chain _SmartCallHome_ServerCA certificate ca 6ecc7aa5a7032009b8cebcf4e952d491 308205ec 308204d4 a0030201 0202106e cc7aa5a7 032009b8 cebcf4e9 52d49130 0d06092a 864886f7 0d010105 05003081 ca310b30 09060355 04061302 55533117 30150603 55040a13 0e566572 69536967 6e2c2049 6e632e31 1f301d06 0355040b 13165665 72695369 676e2054 72757374 204e6574 776f726b 313a3038 06035504 0b133128 63292032 30303620 56657269 5369676e 2c20496e 632e202d 20466f72 20617574 686f7269 7a656420 75736520 6f6e6c79 31453043 06035504 03133c56 65726953 69676e20 436c6173 73203320 5075626c 69632050 72696d61 72792043

NIST SP 1800-8C: Securing Wireless Infusion Pumps

106

65727469 66696361 74696f6e 20417574 686f7269 7479202d 20473530 1e170d31 30303230 38303030 3030305a 170d3230 30323037 32333539 35395a30 81b5310b 30090603 55040613 02555331 17301506 0355040a 130e5665 72695369 676e2c20 496e632e 311f301d 06035504 0b131656 65726953 69676e20 54727573 74204e65 74776f72 6b313b30 39060355 040b1332 5465726d 73206f66 20757365 20617420 68747470 733a2f2f 7777772e 76657269 7369676e 2e636f6d 2f727061 20286329 3130312f 302d0603 55040313 26566572 69536967 6e20436c 61737320 33205365

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

63757265 20536572 76657220 4341202d 20473330 82012230 0d06092a 864886f7 0d010101 05000382 010f0030 82010a02 82010100 b187841f c20c45f5 bcab2597 a7ada23e 9cbaf6c1 39b88bca c2ac56c6 e5bb658e 444f4dce 6fed094a d4af4e10 9c688b2e 957b899b 13cae234 34c1f35b f3497b62 83488174 d188786c 0253f9bc 7f432657 5833833b 330a17b0 d04e9124 ad867d64 12dc744a 34a11d0a ea961d0b 15fca34b 3bce6388 d0f82d0c 948610ca b69a3dca eb379c00 48358629 5078e845 63cd1941 4ff595ec 7b98d4c4 71b350be 28b38fa0 b9539cf5 ca2c23a9 fd1406e8 18b49ae8 3c6e81fd e4cd3536 b351d369 ec12ba56 6e6f9b57 c58b14e7 0ec79ced 4a546ac9 4dc5bf11 b1ae1c67 81cb4455 33997f24 9b3f5345 7f861af3 3cfa6d7f 81f5b84a d3f58537 1cb5a6d0 09e4187b 384efa0f 02030100 01a38201 df308201 db303406 082b0601 05050701 01042830 26302406 082b0601 05050730 01861868 7474703a 2f2f6f63 73702e76 65726973 69676e2e 636f6d30 12060355 1d130101 ff040830 060101ff 02010030 70060355 1d200469 30673065 060b6086 480186f8 45010717 03305630 2806082b 06010505 07020116 1c687474 70733a2f 2f777777 2e766572 69736967 6e2e636f 6d2f6370 73302a06 082b0601 05050702 02301e1a 1c687474 70733a2f 2f777777 2e766572 69736967 6e2e636f 6d2f7270 61303406 03551d1f 042d302b 3029a027 a0258623 68747470 3a2f2f63 726c2e76 65726973 69676e2e 636f6d2f 70636133 2d67352e 63726c30 0e060355 1d0f0101 ff040403 02010630 6d06082b 06010505 07010c04 61305fa1 5da05b30 59305730 55160969 6d616765 2f676966 3021301f 30070605 2b0e0302 1a04148f e5d31a86 ac8d8e6b c3cf806a d448182c 7b192e30 25162368 7474703a 2f2f6c6f 676f2e76 65726973 69676e2e 636f6d2f 76736c6f 676f2e67 69663028 0603551d 11042130 1fa41d30 1b311930 17060355 04031310 56657269 5369676e 4d504b49 2d322d36 301d0603 551d0e04 1604140d 445c1653 44c1827e 1d20ab25 f40163d8 be79a530 1f060355 1d230418 30168014 7fd365a7 c2ddecbb f03009f3 4339fa02 af333133 300d0609

NIST SP 1800-8C: Securing Wireless Infusion Pumps

107

2a864886 f70d0101 05050003 82010100 0c8324ef ddc30cd9 589cfe36 b6eb8a80 4bd1a3f7 9df3cc53 ef829ea3 a1e697c1 589d756c e01d1b4c fad1c12d 05c0ea6e b2227055 d9203340 3307c265 83fa8f43 379bea0e 9a6c70ee f69c803b d937f47a 6decd018 7d494aca 99c71928 a2bed877 24f78526 866d8705 404167d1 273aeddc 481d22cd 0b0b8bbc f4b17bfd b499a8e9 762ae11a 2d876e74 d388dd1e 22c6df16 b62b8214 0a945cf2 50ecafce ff62370d ad65d306 4153ed02 14c8b558 28a1ace0 5becb37f 954afb03 c8ad26db e6667812 4ad99f42 fbe198e6 42839b8f 8f6724e8

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

6119b5dd cdb50b26 058ec36e c4c875b8 46cfe218 065ea9ae a8819a47 16de0c28 6c2527b9 deb78458 c61f381e a4c4cb66 quit telnet timeout 5 ssh stricthostkeycheck ssh 192.168.29.0 255.255.255.0 management ssh timeout 5 ssh version 2 console timeout 0 dhcpd dns 192.168.120.163 192.168.120.162 dhcpd option 3 ip 192.168.140.1 ! dhcpd address 192.168.140.220-192.168.140.250 LAN dhcpd enable LAN ! dynamic-access-policy-record DfltAccessPolicy username [******] password [******] encrypted ! class-map inspection_default match default-inspection-traffic ! ! policy-map type inspect dns migrated_dns_map_1 parameters message-length maximum client auto

NIST SP 1800-8C: Securing Wireless Infusion Pumps

108

message-length maximum 512 policy-map global_policy class inspection_default inspect dns migrated_dns_map_1 inspect ftp inspect h323 h225 inspect h323 ras

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

inspect ip-options inspect netbios inspect rsh inspect rtsp inspect skinny inspect esmtp inspect sqlnet inspect sunrpc inspect tftp inspect sip inspect xdmcp inspect icmp inspect icmp error class class-default set connection decrement-ttl ! service-policy global_policy global prompt hostname context no call-home reporting anonymous call-home profile CiscoTAC-1 no active destination address http https://tools.cisco.com/its/service/oddce/services/DDCEService destination address email callhome@cisco.com

NIST SP 1800-8C: Securing Wireless Infusion Pumps

109

destination transport-method http subscribe-to-alert-group diagnostic subscribe-to-alert-group environment subscribe-to-alert-group inventory periodic monthly subscribe-to-alert-group configuration periodic monthly subscribe-to-alert-group telemetry periodic daily profile License

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

destination address http https://tools.cisco.com/its/service/oddce/services/DDCEService destination transport-method http Cryptochecksum:627e549de0a7dd97cd1379bbf37bc168 : end

A.5 Medical Devices Zone ASA Configuration File : Saved : : Serial Number: 9AEWS2E5JRA : Hardware: ASAv, 2048 MB RAM, CPU Xeon E5 series 2200 MHz : ASA Version 9.6(1) ! hostname medical-devices-kmcfadde enable password [******] encrypted xlate per-session deny tcp any4 any4 xlate per-session deny tcp any4 any6 xlate per-session deny tcp any6 any4 xlate per-session deny tcp any6 any6 xlate per-session deny udp any4 any4 eq domain xlate per-session deny udp any4 any6 eq domain xlate per-session deny udp any6 any4 eq domain xlate per-session deny udp any6 any6 eq domain ! license smart feature tier standard throughput level 1G names ! interface GigabitEthernet0/0 nameif WAN security-level 50 ip address 192.168.100.149 255.255.255.0 ospf authentication-key ***** ospf authentication message-digest ! interface GigabitEthernet0/1

NIST SP 1800-8C: Securing Wireless Infusion Pumps

110

nameif LAN security-level 100 ip address 192.168.150.1 255.255.255.0

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

! interface GigabitEthernet0/2 shutdown no nameif no security-level no ip address ! interface GigabitEthernet0/3 shutdown no nameif no security-level no ip address ! interface GigabitEthernet0/4 shutdown no nameif no security-level no ip address ! interface GigabitEthernet0/5 shutdown no nameif no security-level no ip address ! interface GigabitEthernet0/6 shutdown no nameif no security-level no ip address ! interface GigabitEthernet0/7 shutdown no nameif no security-level no ip address ! interface GigabitEthernet0/8 shutdown no nameif no security-level no ip address ! interface Management0/0 management-only nameif management security-level 0 ip address 192.168.29.149 255.255.255.0 ! ftp mode passive clock timezone EST -5 clock summer-time EDT recurring dns domain-lookup WAN

NIST SP 1800-8C: Securing Wireless Infusion Pumps

111

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

dns server-group DefaultDNS name-server 8.8.8.8 name-server 8.8.4.4 object network SNMPHOSTS subnet 192.168.29.0 255.255.255.0 object network PUMPSERVERS subnet 192.168.140.0 255.255.255.0 object network PUMPS subnet 192.168.150.0 255.255.255.0 object-group icmp-type PING-REPLIES icmp-object echo-reply object-group service PCAPORTS service-object tcp destination eq https service-object tcp destination eq 11444 service-object tcp destination eq 11443 service-object tcp destination eq 8443 object-group icmp-type TRACEROUTE-REPLIES icmp-object time-exceeded icmp-object unreachable group-object PING-REPLIES object-group icmp-type PING icmp-object echo object-group service TRACEROUTEUDP service-object udp destination gt 33434 object-group service PLUM360PORTS service-object tcp destination eq 8100 service-object tcp destination eq 9292 object-group service HOSPIRAPUMPSIMPORTS service-object tcp destination eq https service-object tcp destination eq 8443 object-group service BAXTERPUMPPORTS service-object tcp-udp destination eq 51243 object-group service BBRAUNPORTS service-object tcp destination eq www service-object tcp destination eq https service-object tcp destination eq 8080 service-object tcp destination eq 1500 access-list LAN2WAN extended permit ip object PUMPS object PUMPSERVERS access-list WAN2LAN extended permit object-group PCAPORTS host 192.168.140.160 o bject PUMPS access-list WAN2LAN extended permit icmp any any object-group PING access-list WAN2LAN extended permit object-group TRACEROUTEUDP any any access-list WAN2LAN extended permit icmp any any object-group TRACEROUTE-REPLIES access-list WAN2LAN extended permit icmp any any object-group PING-REPLIES access-list WAN2LAN extended permit object-group PLUM360PORTS host 192.168.140.1 60 object PUMPS access-list WAN2LAN extended permit object-group HOSPIRAPUMPSIMPORTS host 192.16 8.140.160 object PUMPS access-list WAN2LAN extended permit object-group BAXTERPUMPPORTS host 192.168.14 0.165 object PUMPS access-list WAN2LAN extended permit object-group BBRAUNPORTS host 192.168.140.16 9 object PUMPS pager lines 23 mtu WAN 1500 mtu LAN 1500 mtu management 1500

NIST SP 1800-8C: Securing Wireless Infusion Pumps

112

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

no failover no monitor-interface service-module icmp unreachable rate-limit 1 burst-size 1 no asdm history enable arp timeout 14400 no arp permit-nonconnected access-group WAN2LAN in interface WAN access-group LAN2WAN in interface LAN router ospf 1 network 192.168.100.0 255.255.255.0 area 0 log-adj-changes redistribute connected subnets redistribute static subnets ! timeout xlate 3:00:00 timeout pat-xlate 0:00:30 timeout conn 1:00:00 half-closed 0:10:00 udp 0:02:00 sctp 0:02:00 icmp 0:00:02 timeout sunrpc 0:10:00 h323 0:05:00 h225 1:00:00 mgcp 0:05:00 mgcp-pat 0:05:00 timeout sip 0:30:00 sip_media 0:02:00 sip-invite 0:03:00 sip-disconnect 0:02:00 timeout sip-provisional-media 0:02:00 uauth 0:05:00 absolute timeout tcp-proxy-reassembly 0:01:00 timeout floating-conn 0:00:00 user-identity default-domain LOCAL aaa authentication ssh console LOCAL snmp-server host-group management SNMPHOSTS poll community ***** no snmp-server location no snmp-server contact snmp-server community ***** crypto ipsec security-association pmtu-aging infinite crypto ca trustpoint _SmartCallHome_ServerCA no validation-usage crl configure crypto ca trustpool policy auto-import crypto ca certificate chain _SmartCallHome_ServerCA certificate ca 6ecc7aa5a7032009b8cebcf4e952d491 308205ec 308204d4 a0030201 0202106e cc7aa5a7 032009b8 cebcf4e9 52d49130 0d06092a 864886f7 0d010105 05003081 ca310b30 09060355 04061302 55533117 30150603 55040a13 0e566572 69536967 6e2c2049 6e632e31 1f301d06 0355040b 13165665 72695369 676e2054 72757374 204e6574 776f726b 313a3038 06035504 0b133128 63292032 30303620 56657269 5369676e 2c20496e 632e202d 20466f72 20617574 686f7269 7a656420 75736520 6f6e6c79 31453043 06035504 03133c56 65726953 69676e20 436c6173 73203320 5075626c 69632050 72696d61 72792043 65727469 66696361 74696f6e 20417574 686f7269 7479202d 20473530 1e170d31 30303230 38303030 3030305a 170d3230 30323037 32333539 35395a30 81b5310b 30090603 55040613 02555331 17301506 0355040a 130e5665 72695369 676e2c20 496e632e 311f301d 06035504 0b131656 65726953 69676e20 54727573 74204e65 74776f72 6b313b30 39060355 040b1332 5465726d 73206f66 20757365 20617420 68747470 733a2f2f 7777772e 76657269 7369676e 2e636f6d 2f727061 20286329 3130312f 302d0603 55040313 26566572 69536967 6e20436c 61737320 33205365 63757265 20536572 76657220 4341202d 20473330 82012230 0d06092a 864886f7 0d010101 05000382 010f0030 82010a02 82010100 b187841f c20c45f5 bcab2597 a7ada23e 9cbaf6c1 39b88bca c2ac56c6 e5bb658e 444f4dce 6fed094a d4af4e10 9c688b2e 957b899b 13cae234 34c1f35b f3497b62 83488174 d188786c 0253f9bc 7f432657 5833833b 330a17b0 d04e9124 ad867d64 12dc744a 34a11d0a ea961d0b 15fca34b 3bce6388 d0f82d0c 948610ca b69a3dca eb379c00 48358629 5078e845

NIST SP 1800-8C: Securing Wireless Infusion Pumps

113

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

63cd1941 4ff595ec 7b98d4c4 71b350be 28b38fa0 b9539cf5 ca2c23a9 fd1406e8 18b49ae8 3c6e81fd e4cd3536 b351d369 ec12ba56 6e6f9b57 c58b14e7 0ec79ced 4a546ac9 4dc5bf11 b1ae1c67 81cb4455 33997f24 9b3f5345 7f861af3 3cfa6d7f 81f5b84a d3f58537 1cb5a6d0 09e4187b 384efa0f 02030100 01a38201 df308201 db303406 082b0601 05050701 01042830 26302406 082b0601 05050730 01861868 7474703a 2f2f6f63 73702e76 65726973 69676e2e 636f6d30 12060355 1d130101 ff040830 060101ff 02010030 70060355 1d200469 30673065 060b6086 480186f8 45010717 03305630 2806082b 06010505 07020116 1c687474 70733a2f 2f777777 2e766572 69736967 6e2e636f 6d2f6370 73302a06 082b0601 05050702 02301e1a 1c687474 70733a2f 2f777777 2e766572 69736967 6e2e636f 6d2f7270 61303406 03551d1f 042d302b 3029a027 a0258623 68747470 3a2f2f63 726c2e76 65726973 69676e2e 636f6d2f 70636133 2d67352e 63726c30 0e060355 1d0f0101 ff040403 02010630 6d06082b 06010505 07010c04 61305fa1 5da05b30 59305730 55160969 6d616765 2f676966 3021301f 30070605 2b0e0302 1a04148f e5d31a86 ac8d8e6b c3cf806a d448182c 7b192e30 25162368 7474703a 2f2f6c6f 676f2e76 65726973 69676e2e 636f6d2f 76736c6f 676f2e67 69663028 0603551d 11042130 1fa41d30 1b311930 17060355 04031310 56657269 5369676e 4d504b49 2d322d36 301d0603 551d0e04 1604140d 445c1653 44c1827e 1d20ab25 f40163d8 be79a530 1f060355 1d230418 30168014 7fd365a7 c2ddecbb f03009f3 4339fa02 af333133 300d0609 2a864886 f70d0101 05050003 82010100 0c8324ef ddc30cd9 589cfe36 b6eb8a80 4bd1a3f7 9df3cc53 ef829ea3 a1e697c1 589d756c e01d1b4c fad1c12d 05c0ea6e b2227055 d9203340 3307c265 83fa8f43 379bea0e 9a6c70ee f69c803b d937f47a 6decd018 7d494aca 99c71928 a2bed877 24f78526 866d8705 404167d1 273aeddc 481d22cd 0b0b8bbc f4b17bfd b499a8e9 762ae11a 2d876e74 d388dd1e 22c6df16 b62b8214 0a945cf2 50ecafce ff62370d ad65d306 4153ed02 14c8b558 28a1ace0 5becb37f 954afb03 c8ad26db e6667812 4ad99f42 fbe198e6 42839b8f 8f6724e8 6119b5dd cdb50b26 058ec36e c4c875b8 46cfe218 065ea9ae a8819a47 16de0c28 6c2527b9 deb78458 c61f381e a4c4cb66 quit telnet timeout 5 ssh stricthostkeycheck ssh 192.168.29.0 255.255.255.0 management ssh timeout 5 ssh version 2 console timeout 0 dhcpd dns 192.168.150.1 dhcpd option 3 ip 192.168.150.1 ! dhcpd address 192.168.150.220-192.168.150.250 LAN dhcpd enable LAN ! dynamic-access-policy-record DfltAccessPolicy username [******]password [******] encrypted ! class-map inspection_default match default-inspection-traffic ! ! policy-map type inspect dns migrated_dns_map_1 parameters message-length maximum client auto message-length maximum 512 policy-map global_policy class inspection_default inspect dns migrated_dns_map_1 inspect ftp

NIST SP 1800-8C: Securing Wireless Infusion Pumps

114

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

inspect h323 h225 inspect h323 ras inspect ip-options inspect netbios inspect rsh inspect rtsp inspect skinny inspect esmtp inspect sqlnet inspect sunrpc inspect tftp inspect sip inspect xdmcp inspect icmp inspect icmp error class class-default set connection decrement-ttl ! service-policy global_policy global prompt hostname context no call-home reporting anonymous call-home profile CiscoTAC-1 no active destination address http https://tools.cisco.com/its/service/oddce/services/DD CEService destination address email callhome@cisco.com destination transport-method http subscribe-to-alert-group diagnostic subscribe-to-alert-group environment subscribe-to-alert-group inventory periodic monthly subscribe-to-alert-group configuration periodic monthly subscribe-to-alert-group telemetry periodic daily profile License destination address http https://tools.cisco.com/its/service/oddce/services/DD CEService destination transport-method http Cryptochecksum:b2e10eb9d982ddbe5330e964af80d2d3 : end

A.6 Switch Configuration File ! ! Last configuration change at 22:21:08 UTC Wed Feb 22 2017 by cisco ! NVRAM config last updated at 23:22:47 UTC Wed Feb 22 2017 by cisco ! version 15.0 no service pad service timestamps debug datetime msec service timestamps log datetime msec service password-encryption service compress-config ! hostname Cisco3650-01 !

NIST SP 1800-8C: Securing Wireless Infusion Pumps

115

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

boot-start-marker boot-end-marker ! ! vrf definition Mgmt-vrf ! address-family ipv4 exit-address-family ! address-family ipv6 exit-address-family ! logging console emergencies enable secret [******] enable password [******] ! username [******]privilege [**] password [******] user-name [******] creation-time 1469560730 privilege [**] password [******] type mgmt-user no aaa new-model switch 1 provision ws-c3650-48ps ! ip domain-name [******] ip device tracking ip dhcp excluded-address 192.168.250.1 192.168.250.9 ! ip dhcp pool WLAN network 192.168.250.0 255.255.255.0 default-router 192.168.250.1 option 43 hex c0a8.fa02 ! ! vtp mode transparent ! crypto pki trustpoint TP-self-signed-2035642131 enrollment selfsigned subject-name cn=IOS-Self-Signed-Certificate-2035642131 revocation-check none rsakeypair TP-self-signed-2035642131 ! ! crypto pki certificate chain TP-self-signed-2035642131 certificate self-signed 01 3082024D 308201B6 A0030201 02020101 300D0609 2A864886 F70D0101 04050030 31312F30 2D060355 04031326 494F532D 53656C66 2D536967 6E65642D 43657274 69666963 6174652D 32303335 36343231 3331301E 170D3136 30373236 32303436 32355A17 0D323030 31303130 30303030 305A3031 312F302D 06035504 03132649 4F532D53 656C662D 5369676E 65642D43 65727469 66696361 74652D32 30333536 34323133 3130819F 300D0609 2A864886 F70D0101 01050003 818D0030 81890281 8100F1C4 010AE138 9BD9BBCC 2E563180 698979B5 51F7B46B D122595E E7033DCA D80C9432 0728E47F 8CAC2629 40CEC617 5CDFFBD9 19744025 CB62CA75 8F6F0A9A 34F790DD 07DA9D60 737196C1 FDD9E764 6D22EDA3 8D9E7DF5 6CD934E3 D89FA9D5 C165F3EE E9E0EA9F 37742B00 2C4CFA0B C262E61B 95565B42 302B23E7 A1C85D9F

NIST SP 1800-8C: Securing Wireless Infusion Pumps

116

5FDB0203 010001A3 75307330 0F060355 1D130101 FF040530 030101FF 30200603 551D1104 19301782 15436973 636F3336 35302D30 312E6E69 73742E67 6F76301F 0603551D 23041830 1680148F 3A1CDEB7 502DACB7 DF4E96E4 EA1470F1 CFD1F730 1D060355 1D0E0416 04148F3A 1CDEB750 2DACB7DF 4E96E4EA 1470F1CF D1F7300D 06092A86 4886F70D 01010405 00038181 004FE025 9B72B4D2 5391B847 F443B481 4493F8BD 69D2FF3A 3C2E6D96 D7D83B92 91DBB84D DD47E242 9B2F45AC CA7C7CBC D7CB9660 2B07AE9B 0376D5A1 15CBA04B B326AADE AB213EB1 D625FBFF B2F54CCD 40B1EB91 C6DD5E33 DEA8EEB3 20ECDE96 F42527D6 AD1F6A5D A261D394 FE358B8F 317FAFD0 E853785D 777E1E1D 6F561A2A 07 quit

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

! ! ! ! ! diagnostic bootup level minimal spanning-tree mode pvst spanning-tree extend system-id ! redundancy mode sso ! ! vlan 20 ! vlan 1400 name IP_DEV_BIOMEDICAL ! vlan 1500 name IP_DEV ! vlan 1520 name WIFI_MGMT ! ip ssh version 2 ! class-map match-any non-client-nrt-class match non-client-nrt ! policy-map port_child_policy class non-client-nrt-class bandwidth remaining ratio 10 ! ! ! ! ! ! interface GigabitEthernet0/0 vrf forwarding Mgmt-vrf ip address 192.168.20.13 255.255.255.0 negotiation auto ! interface GigabitEthernet1/0/1 switchport access vlan 1520 switchport mode access

NIST SP 1800-8C: Securing Wireless Infusion Pumps

117

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

spanning-tree portfast ! interface GigabitEthernet1/0/2 switchport access vlan 1520 switchport mode access spanning-tree portfast ! interface GigabitEthernet1/0/3 switchport access vlan 1520 switchport mode access spanning-tree portfast ! interface GigabitEthernet1/0/4 switchport access vlan 1520 switchport mode access spanning-tree portfast ! interface GigabitEthernet1/0/5 spanning-tree portfast ! interface GigabitEthernet1/0/6 spanning-tree portfast ! interface GigabitEthernet1/0/7 spanning-tree portfast ! interface GigabitEthernet1/0/8 spanning-tree portfast ! interface GigabitEthernet1/0/9 spanning-tree portfast ! interface GigabitEthernet1/0/10 spanning-tree portfast ! interface GigabitEthernet1/0/11 spanning-tree portfast ! interface GigabitEthernet1/0/12 spanning-tree portfast ! interface GigabitEthernet1/0/13 spanning-tree portfast ! interface GigabitEthernet1/0/14 spanning-tree portfast ! interface GigabitEthernet1/0/15 spanning-tree portfast ! interface GigabitEthernet1/0/16 spanning-tree portfast ! interface GigabitEthernet1/0/17 spanning-tree portfast !

NIST SP 1800-8C: Securing Wireless Infusion Pumps

118

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

interface GigabitEthernet1/0/18 spanning-tree portfast ! interface GigabitEthernet1/0/19 spanning-tree portfast ! interface GigabitEthernet1/0/20 spanning-tree portfast ! interface GigabitEthernet1/0/21 spanning-tree portfast ! interface GigabitEthernet1/0/22 spanning-tree portfast ! interface GigabitEthernet1/0/23 spanning-tree portfast ! interface GigabitEthernet1/0/24 spanning-tree portfast ! interface GigabitEthernet1/0/25 spanning-tree portfast ! interface GigabitEthernet1/0/26 spanning-tree portfast ! interface GigabitEthernet1/0/27 spanning-tree portfast ! interface GigabitEthernet1/0/28 spanning-tree portfast ! interface GigabitEthernet1/0/29 spanning-tree portfast ! interface GigabitEthernet1/0/30 spanning-tree portfast ! interface GigabitEthernet1/0/31 spanning-tree portfast ! interface GigabitEthernet1/0/32 spanning-tree portfast ! interface GigabitEthernet1/0/33 spanning-tree portfast ! interface GigabitEthernet1/0/34 spanning-tree portfast ! interface GigabitEthernet1/0/35 spanning-tree portfast ! interface GigabitEthernet1/0/36 spanning-tree portfast

NIST SP 1800-8C: Securing Wireless Infusion Pumps

119

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

! interface GigabitEthernet1/0/37 spanning-tree portfast ! interface GigabitEthernet1/0/38 spanning-tree portfast ! interface GigabitEthernet1/0/39 spanning-tree portfast ! interface GigabitEthernet1/0/40 spanning-tree portfast ! interface GigabitEthernet1/0/41 switchport access vlan 1400 spanning-tree portfast ! interface GigabitEthernet1/0/42 switchport access vlan 1400 spanning-tree portfast ! interface GigabitEthernet1/0/43 switchport access vlan 1400 spanning-tree portfast ! interface GigabitEthernet1/0/44 switchport access vlan 1400 spanning-tree portfast ! interface GigabitEthernet1/0/45 description Set to 10/Half for Hospira switchport access vlan 1500 speed 10 duplex half spanning-tree portfast ! interface GigabitEthernet1/0/46 switchport access vlan 1500 spanning-tree portfast ! interface GigabitEthernet1/0/47 description VLAN trunk switchport trunk allowed vlan 1400,1500,1520 switchport mode trunk spanning-tree portfast ! interface GigabitEthernet1/0/48 description management connection on VL20 switchport access vlan 20 spanning-tree portfast ! interface GigabitEthernet1/1/1 ! interface GigabitEthernet1/1/2 ! interface GigabitEthernet1/1/3

NIST SP 1800-8C: Securing Wireless Infusion Pumps

120

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

! interface GigabitEthernet1/1/4 ! interface Vlan1 no ip address shutdown ! interface Vlan20 ip address 192.168.20.13 255.255.255.0 ! interface Vlan1520 description Wireless-MGMT ip address 192.168.250.1 255.255.255.0 ! no ip http server no ip http secure-server ip route 0.0.0.0 0.0.0.0 192.168.20.254 ! ip access-list extended SSH-Access permit tcp 192.168.20.0 0.0.0.255 any eq 22 deny ip any any log ! access-list 10 permit 192.168.20.0 0.0.0.255 ! snmp-server community public RO 10 snmp-server location NCCoE snmp-server contact <email-address> ! ! line con 0 exec-timeout 0 0 stopbits 1 line aux 0 stopbits 1 line vty 0 4 access-class SSH-Access in exec-timeout 300 0 password [******] login local transport input ssh line vty 5 15 access-class SSH-Access in exec-timeout 300 0 password [******] login local transport input ssh ! ntp server 10.97.74.8 wsma agent exec profile httplistener profile httpslistener wsma agent config profile httplistener profile httpslistener wsma agent filesys profile httplistener

NIST SP 1800-8C: Securing Wireless Infusion Pumps

121

profile httpslistener wsma agent notify profile httplistener profile httpslistener ! wsma profile listener httplistener transport http ! wsma profile listener httpslistener transport https ap group default-group end

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

A.7 Wireless Configuration System Inventory NAME: "Chassis"

, DESCR: "Cisco Wireless Controller"

PID: AIR-CTVM-K9,

VID: V01,

SN: 96NTPERK0A6

Burned-in MAC Address............................ 00:50:56:AC:6D:08 Maximum number of APs supported.................. 200

System Information Manufacturer's Name.............................. Cisco Systems Inc. Product Name..................................... Cisco Controller Product Version.................................. 8.2.111.0 RTOS Version..................................... 8.2.111.0 Bootloader Version............................... 8.2.111.0 Emergency Image Version.......................... 8.2.111.0

Build Type....................................... DATA + WPS

System Name...................................... wlc System Location.................................. System Contact................................... System ObjectID.................................. 1.3.6.1.4.1.9.1.1631 IP Address....................................... 192.168.250.2 IPv6 Address..................................... ::

NIST SP 1800-8C: Securing Wireless Infusion Pumps

122

System Up Time................................... 6 days 3 hrs 48 mins 20 secs System Timezone Location......................... System Stats Realtime Interval................... 5 System Stats Normal Interval..................... 180

Configured Country............................... US

- United States

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

State of 802.11b Network......................... Enabled State of 802.11a Network......................... Enabled Number of WLANs.................................. 2 Number of Active Clients......................... 2

Burned-in MAC Address............................ 00:50:56:AC:6D:08 Maximum number of APs supported.................. 200 System Nas-Id.................................... Licensing Type................................... RTU vWLC config...................................... Small

Backup Controller Configuration

AP primary Backup Controller .................... AP secondary Backup Controller ..................

System Time Information:

Time............................................. Thu Aug 18 20:05:16 2016

Timezone delta................................... 0:0 Timezone location................................

NTP Servers

NIST SP 1800-8C: Securing Wireless Infusion Pumps

123

NTP Polling Interval.........................

Index NTP Key Index NTP Msg Auth Status

3600

NTP Server

Status

------- --------------------------------------------------------------------------------------------1 AUTH DISABLED

0

192.168.250.1

Not Synched

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

Redundancy Information Redundancy Mode ................................. SSO DISABLED Local State...................................... ACTIVE Peer State....................................... N/A Unit............................................. Primary Unit ID.......................................... 00:50:56:AC:6D:08 Redunadancy State................................ N/A Mobility MAC..................................... 00:50:56:AC:6D:08 Redundancy Management IP Address................. 0.0.0.0 Peer Redundancy Management IP Address............ 0.0.0.0 Redundancy Port IP Address....................... 0.0.0.0 Peer Redundancy Port IP Address.................. 169.254.0.0

AP Bundle Information

Primary AP Image

Size

----------------

----

ap1g1

12660

ap1g2

11748

ap1g3

13672

ap1g4

19256

ap3g1

9736

ap3g2

13480

ap3g3

18696

NIST SP 1800-8C: Securing Wireless Infusion Pumps

124

ap801

8064

ap802

9536

c1140

8636

c1520

7344

c1550

10628

c1570

11536

c602i

3864

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

version.info

4

Secondary AP Image

Size

------------------

----

ap1g1

12660

ap1g2

11748

ap1g3

13672

ap1g4

19256

ap3g1

9736

ap3g2

13480

ap3g3

18696

ap801

8064

ap802

9536

c1140

8636

c1520

7344

c1550

10628

c1570

11536

c602i

3864

version.info

4

Switch Configuration 802.3x Flow Control Mode......................... Disable FIPS prerequisite features....................... Disabled WLANCC prerequisite features..................... Disabled UCAPL prerequisite features...................... Disabled

NIST SP 1800-8C: Securing Wireless Infusion Pumps

125

secret obfuscation............................... Enabled Strong Password Check Features case-check.................................... Enabled consecutive-check............................. Enabled default-check................................. Enabled username-check................................ Enabled position-check................................ Disabled

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

case-digit-check.............................. Disabled Min. Password length.......................... 3 Min. Upper case chars......................... 0 Min. Lower case chars......................... 0 Min. Digits chars............................. 0 Min. Special chars............................ 0 Mgmt User Password Lifetime [days]...................... 0 Password Lockout.............................. Disabled Lockout Attempts.............................. 3 Lockout Timeout [mins]........................ 5 SNMPv3 User Password Lifetime [days]...................... 0 Password Lockout.............................. Disabled Lockout Attempts.............................. 3 Lockout Timeout [mins]........................ 5

Network Information RF-Network Name............................. WLAN DNS Server IP............................... Web Mode.................................... Disable Secure Web Mode............................. Enable Secure Web Mode Cipher-Option High.......... Disable Secure Web Mode Cipher-Option SSLv2......... Disable Secure Web Mode RC4 Cipher Preference....... Disable

NIST SP 1800-8C: Securing Wireless Infusion Pumps

126

Secure Web Mode SSL Protocol................ Disable OCSP........................................ Disabled OCSP responder URL.......................... Secure Shell (ssh).......................... Enable Secure Shell (ssh) Cipher-Option High....... Disable Telnet...................................... Disable Ethernet Multicast Forwarding............... Disable

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

Ethernet Broadcast Forwarding............... Disable IPv4 AP Multicast/Broadcast Mode............ Unicast IPv6 AP Multicast/Broadcast Mode............ Unicast IGMP snooping............................... Disabled IGMP timeout................................ 60 seconds IGMP Query Interval......................... 20 seconds MLD snooping................................ Disabled MLD timeout................................. 60 seconds MLD query interval.......................... 20 seconds User Idle Timeout........................... 300 seconds ARP Idle Timeout............................ 300 seconds Cisco AP Default Master..................... Disable AP Join Priority............................ Disable Mgmt Via Wireless Interface................. Disable Mgmt Via Dynamic Interface.................. Disable Bridge MAC filter Config.................... Enable Bridge Security Mode........................ EAP Mesh Full Sector DFS........................ Enable Mesh Backhaul RRM........................... Disable AP Fallback ................................ Enable Web Auth CMCC Support ...................... Disabled Web Auth Redirect Ports .................... 80 Web Auth Proxy Redirect

................... Disable

Web Auth Captive-Bypass

.................. Disable

Web Auth Secure Web

....................... Enable

NIST SP 1800-8C: Securing Wireless Infusion Pumps

127

Web Auth Secure Redirection

............... Disable

Fast SSID Change ........................... Disabled AP Discovery - NAT IP Only ................. Enabled IP/MAC Addr Binding Check .................. Enabled Link Local Bridging Status ................. Disabled CCX-lite status ............................ Disable oeap-600 dual-rlan-ports ................... Disable

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

oeap-600 local-network ..................... Enable oeap-600 Split Tunneling (Printers)......... Disable WebPortal Online Client .................... 0 WebPortal NTF_LOGOUT Client ................ 0 mDNS snooping............................... Disabled mDNS Query Interval......................... 15 minutes Web Color Theme............................. Default Capwap Prefer Mode.......................... IPv4 Network Profile............................. Disabled Client ip conflict detection (DHCP) ........ Disabled Mesh BH RRM ................................ Disable Mesh Aggressive DCA......................... Disable Mesh Auto RF................................ Disable HTTP Profiling Port......................... 80

Port Summary

Pr

Type

STP

Admin

Physical

Physical

Link

Link

Stat

Mode

Mode

Status

Status

Trap

POE

-- ------- ---- ------- ---------- ---------- ------ ------- --------1

Normal

Forw Enable

Auto

1000 Full

Up

Enable

N/A

AP Summary Number of APs.................................... 2

Global AP User Name.............................. Not Configured Global AP Dot1x User Name........................ Not Configured

NIST SP 1800-8C: Securing Wireless Infusion Pumps

128

AP Name Country

Slots IP Address

AP Model Clients

Ethernet MAC DSE Location

Location

------------------ ----- -------------------- -------------------------- --------------- -------- --------------

----------------

AP78da.6ee0.08ec 2 AIR-CAP1602I-A-K9 78:da:6e:e0:08:ec US 192.168.250.10 0 [0 ,0 ,0 ]

default location

AP24e9.b34b.f1ed 2 AIR-CAP1602I-A-K9 24:e9:b3:4b:f1:ed US 192.168.250.11 1 [0 ,0 ,0 ]

default location

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

AP Tcp-Mss-Adjust Info AP Name

TCP State

MSS Size

------------------

--------

-------

AP78da.6ee0.08ec

disabled

-

AP24e9.b34b.f1ed

disabled

-

AP Location Total Number of AP Groups........................ 1

Site Name........................................ default-group Site Description................................. <none> NAS-identifier................................... none Client Traffic QinQ Enable....................... FALSE DHCPv4 QinQ Enable............................... FALSE AP Operating Class............................... Not-configured Capwap Prefer Mode............................... Not-configured

RF Profile ---------2.4 GHz band..................................... <none> 5 GHz band....................................... <none>

WLAN ID

Interface

NIST SP 1800-8C: Securing Wireless Infusion Pumps

Network Admission Control

Radio Policy

129

-------

-----------

--------------------------

------------

1

ip_dev

Disabled

None

2

ip_dev

Disabled

None

*AP3600 with 802.11ac Module will only advertise first 8 WLANs on 5GHz radios.

Lan Port configs

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

----------------

LAN

Status

POE

RLAN

---

-------

----

-----

1

Disabled

Disabled

None

2

Disabled

None

3

Disabled

None

External 3G/4G module configs -----------------------------

LAN

Status

POE

RLAN

---

-------

----

-----

1

Disabled

AP Name Port Country

None

Slots Priority

AP Model

Ethernet MAC

Location

------------------ ------- ------- --------

-------------------

-----------------

----------------

-

AP78da.6ee0.08ec US 1

2

AIR-CAP1602I-A-K9

78:da:6e:e0:08:ec

default location

1

AP24e9.b34b.f1ed US 1

2

AIR-CAP1602I-A-K9

24:e9:b3:4b:f1:ed

default location

1

RF Profile

NIST SP 1800-8C: Securing Wireless Infusion Pumps

130

Number of RF Profiles............................ 6

Out Of Box State................................. Disabled

Out Of Box Persistence........................... Disabled

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

RF Profile Name client-only Applied

Band

Description

11n-

--------------------------------------------- ----------

-------

-----------------------------------

-----

High-Client-Density-802.11a disable No

5 GHz

<none>

High-Client-Density-802.11bg disable No

2.4 GHz

<none>

Low-Client-Density-802.11a disable No

5 GHz

<none>

Low-Client-Density-802.11bg disable No

2.4 GHz

<none>

Typical-Client-Density-802.11a disable No

5 GHz

<none>

Typical-Client-Density-802.11bg disable No

2.4 GHz

<none>

RF Profile name................................ High-Client-Density-802.11a Description...................................... <none> AP Group Name.................................... <none> Radio policy..................................... 5 GHz 11n-client-only.................................. disabled Transmit Power Threshold v1...................... -65 dBm Transmit Power Threshold v2...................... -67 dBm Min Transmit Power............................... 7 dBm Max Transmit Power............................... 30 dBm 802.11a Operational Rates 802.11a 6M Rate.............................. Disabled

NIST SP 1800-8C: Securing Wireless Infusion Pumps

131

802.11a 9M Rate.............................. Disabled 802.11a 12M Rate............................. Mandatory 802.11a 18M Rate............................. Supported 802.11a 24M Rate............................. Mandatory 802.11a 36M Rate............................. Supported 802.11a 48M Rate............................. Supported 802.11a 54M Rate............................. Supported

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

Max Clients...................................... 200

WLAN ID

Max Clients

-------

-------

1

600

2

600

Trap Threshold Clients...................................... 12 clients Interference................................. 10 % Noise........................................ -70 dBm Utilization.................................. 80 % Multicast Data Rate.............................. 0 Rx Sop Threshold................................. -78 dBm Cca Threshold.................................... 0 dBm Slot Admin State:................................ Enabled

Band Select Probe Response............................... Disabled Cycle Count.................................. 2 cycles Cycle Threshold.............................. 200 milliseconds Expire Suppression........................... 20 seconds Expire Dual Band............................. 60 seconds Client Rssi.................................. -80 dBm Client Mid Rssi.............................. -80 dBm

NIST SP 1800-8C: Securing Wireless Infusion Pumps

132

Load Balancing Denial....................................... 3 count Window....................................... 5 clients

Coverage Data Data......................................... -80 dBm

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

Voice........................................ -80 dBm Minimum Client Level......................... 3 clients Exception Level.............................. 25 % DCA Channel List................................. 36,40,44,48,52,56,60,64,100, 104,108,112,116,120,124,128, 132,136,140,144,149,153,157, 161 DCA Bandwidth.................................... 20 DCA Foreign AP Contribution...................... enabled

802.11n MCS Rates MCS-00 Rate.................................. enabled MCS-01 Rate.................................. enabled MCS-02 Rate.................................. enabled MCS-03 Rate.................................. enabled MCS-04 Rate.................................. enabled MCS-05 Rate.................................. enabled MCS-06 Rate.................................. enabled MCS-07 Rate.................................. enabled MCS-08 Rate.................................. enabled MCS-09 Rate.................................. enabled MCS-10 Rate.................................. enabled MCS-11 Rate.................................. enabled MCS-12 Rate.................................. enabled MCS-13 Rate.................................. enabled

NIST SP 1800-8C: Securing Wireless Infusion Pumps

133

MCS-14 Rate.................................. enabled MCS-15 Rate.................................. enabled MCS-16 Rate.................................. enabled MCS-17 Rate.................................. enabled MCS-18 Rate.................................. enabled MCS-19 Rate.................................. enabled MCS-20 Rate.................................. enabled

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

MCS-21 Rate.................................. enabled MCS-22 Rate.................................. enabled MCS-23 Rate.................................. enabled MCS-24 Rate.................................. enabled MCS-25 Rate.................................. enabled MCS-26 Rate.................................. enabled MCS-27 Rate.................................. enabled MCS-28 Rate.................................. enabled MCS-29 Rate.................................. enabled MCS-30 Rate.................................. enabled MCS-31 Rate.................................. enabled Client Network Preference....................... default

RF Profile name................................ High-Client-Density-802.11bg Description...................................... <none> AP Group Name.................................... <none> Radio policy..................................... 2.4 GHz 11n-client-only.................................. disabled Transmit Power Threshold v1...................... -70 dBm Transmit Power Threshold v2...................... -67 dBm Min Transmit Power............................... 7 dBm Max Transmit Power............................... 30 dBm 802.11b/g Operational Rates 802.11b/g 1M Rate............................ Disabled 802.11b/g 2M Rate............................ Disabled

NIST SP 1800-8C: Securing Wireless Infusion Pumps

134

802.11b/g 5.5M Rate.......................... Disabled 802.11b/g 11M Rate........................... Disabled 802.11g 6M Rate.............................. Disabled 802.11g 9M Rate.............................. Supported 802.11g 12M Rate............................. Mandatory 802.11g 18M Rate............................. Supported 802.11g 24M Rate............................. Supported

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

802.11g 36M Rate............................. Supported 802.11g 48M Rate............................. Supported 802.11g 54M Rate............................. Supported Max Clients...................................... 200

WLAN ID

Max Clients

-------

-------

1

600

2

600

Trap Threshold Clients...................................... 12 clients Interference................................. 10 % Noise........................................ -70 dBm Utilization.................................. 80 % Multicast Data Rate.............................. 0 Rx Sop Threshold................................. -82 dBm Cca Threshold.................................... 0 dBm Slot Admin State:................................ Enabled

Band Select Probe Response............................... Disabled Cycle Count.................................. 2 cycles Cycle Threshold.............................. 200 milliseconds Expire Suppression........................... 20 seconds

NIST SP 1800-8C: Securing Wireless Infusion Pumps

135

Expire Dual Band............................. 60 seconds Client Rssi.................................. -80 dBm Client Mid Rssi.............................. -80 dBm

Load Balancing Denial....................................... 3 count Window....................................... 5 clients

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

Coverage Data Data......................................... -80 dBm Voice........................................ -80 dBm Minimum Client Level......................... 3 clients Exception Level.............................. 25 % DCA Channel List................................. 1,6,11 DCA Bandwidth.................................... 20 DCA Foreign AP Contribution...................... enabled

802.11n MCS Rates MCS-00 Rate.................................. enabled MCS-01 Rate.................................. enabled MCS-02 Rate.................................. enabled MCS-03 Rate.................................. enabled MCS-04 Rate.................................. enabled MCS-05 Rate.................................. enabled MCS-06 Rate.................................. enabled MCS-07 Rate.................................. enabled MCS-08 Rate.................................. enabled MCS-09 Rate.................................. enabled MCS-10 Rate.................................. enabled MCS-11 Rate.................................. enabled MCS-12 Rate.................................. enabled MCS-13 Rate.................................. enabled

NIST SP 1800-8C: Securing Wireless Infusion Pumps

136

MCS-14 Rate.................................. enabled MCS-15 Rate.................................. enabled MCS-16 Rate.................................. enabled MCS-17 Rate.................................. enabled MCS-18 Rate.................................. enabled MCS-19 Rate.................................. enabled MCS-20 Rate.................................. enabled

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

MCS-21 Rate.................................. enabled MCS-22 Rate.................................. enabled MCS-23 Rate.................................. enabled MCS-24 Rate.................................. enabled MCS-25 Rate.................................. enabled MCS-26 Rate.................................. enabled MCS-27 Rate.................................. enabled MCS-28 Rate.................................. enabled MCS-29 Rate.................................. enabled MCS-30 Rate.................................. enabled MCS-31 Rate.................................. enabled Client Network Preference....................... default

RF Profile name................................ Low-Client-Density-802.11a Description...................................... <none> AP Group Name.................................... <none> Radio policy..................................... 5 GHz 11n-client-only.................................. disabled Transmit Power Threshold v1...................... -60 dBm Transmit Power Threshold v2...................... -67 dBm Min Transmit Power............................... -10 dBm Max Transmit Power............................... 30 dBm 802.11a Operational Rates 802.11a 6M Rate.............................. Mandatory 802.11a 9M Rate.............................. Supported

NIST SP 1800-8C: Securing Wireless Infusion Pumps

137

802.11a 12M Rate............................. Mandatory 802.11a 18M Rate............................. Supported 802.11a 24M Rate............................. Mandatory 802.11a 36M Rate............................. Supported 802.11a 48M Rate............................. Supported 802.11a 54M Rate............................. Supported Max Clients...................................... 200

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

WLAN ID

Max Clients

-------

-------

1

600

2

600

Trap Threshold Clients...................................... 12 clients Interference................................. 10 % Noise........................................ -70 dBm Utilization.................................. 80 % Multicast Data Rate.............................. 0 Rx Sop Threshold................................. -80 dBm Cca Threshold.................................... 0 dBm Slot Admin State................................ Enabled

Band Select Probe Response............................... Disabled Cycle Count.................................. 2 cycles Cycle Threshold.............................. 200 milliseconds Expire Suppression........................... 20 seconds Expire Dual Band............................. 60 seconds Client Rssi.................................. -80 dBm Client Mid Rssi.............................. -80 dBm

NIST SP 1800-8C: Securing Wireless Infusion Pumps

138

Load Balancing Denial....................................... 3 count Window....................................... 5 clients

Coverage Data Data......................................... -90 dBm Voice........................................ -90 dBm

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

Minimum Client Level......................... 2 clients Exception Level.............................. 25 % DCA Channel List................................. 36,40,44,48,52,56,60,64,100, 104,108,112,116,120,124,128, 132,136,140,144,149,153,157, 161 DCA Bandwidth.................................... 20 DCA Foreign AP Contribution...................... enabled

802.11n MCS Rates MCS-00 Rate.................................. enabled MCS-01 Rate.................................. enabled MCS-02 Rate.................................. enabled MCS-03 Rate.................................. enabled MCS-04 Rate.................................. enabled MCS-05 Rate.................................. enabled MCS-06 Rate.................................. enabled MCS-07 Rate.................................. enabled MCS-08 Rate.................................. enabled MCS-09 Rate.................................. enabled MCS-10 Rate.................................. enabled MCS-11 Rate.................................. enabled MCS-12 Rate.................................. enabled MCS-13 Rate.................................. enabled MCS-14 Rate.................................. enabled

NIST SP 1800-8C: Securing Wireless Infusion Pumps

139

MCS-15 Rate.................................. enabled MCS-16 Rate.................................. enabled MCS-17 Rate.................................. enabled MCS-18 Rate.................................. enabled MCS-19 Rate.................................. enabled MCS-20 Rate.................................. enabled MCS-21 Rate.................................. enabled

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

MCS-22 Rate.................................. enabled MCS-23 Rate.................................. enabled MCS-24 Rate.................................. enabled MCS-25 Rate.................................. enabled MCS-26 Rate.................................. enabled MCS-27 Rate.................................. enabled MCS-28 Rate.................................. enabled MCS-29 Rate.................................. enabled MCS-30 Rate.................................. enabled MCS-31 Rate.................................. enabled Client Network Preference....................... default

RF Profile name................................ Low-Client-Density-802.11bg Description...................................... <none> AP Group Name.................................... <none> Radio policy..................................... 2.4 GHz 11n-client-only.................................. disabled Transmit Power Threshold v1...................... -65 dBm Transmit Power Threshold v2...................... -67 dBm Min Transmit Power............................... -10 dBm Max Transmit Power............................... 30 dBm 802.11b/g Operational Rates 802.11b/g 1M Rate............................ Mandatory 802.11b/g 2M Rate............................ Mandatory 802.11b/g 5.5M Rate.......................... Mandatory

NIST SP 1800-8C: Securing Wireless Infusion Pumps

140

802.11b/g 11M Rate........................... Mandatory 802.11g 6M Rate.............................. Supported 802.11g 9M Rate.............................. Supported 802.11g 12M Rate............................. Supported 802.11g 18M Rate............................. Supported 802.11g 24M Rate............................. Supported 802.11g 36M Rate............................. Supported

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

802.11g 48M Rate............................. Supported 802.11g 54M Rate............................. Supported Max Clients...................................... 200

WLAN ID

Max Clients

-------

-------

1

600

2

600

Trap Threshold Clients...................................... 12 clients Interference................................. 10 % Noise........................................ -70 dBm Utilization.................................. 80 % Multicast Data Rate.............................. 0 Rx Sop Threshold................................. -85 dBm Cca Threshold.................................... 0 dBm Slot Admin State:................................ Enabled

Band Select Probe Response............................... Disabled Cycle Count.................................. 2 cycles Cycle Threshold.............................. 200 milliseconds Expire Suppression........................... 20 seconds Expire Dual Band............................. 60 seconds

NIST SP 1800-8C: Securing Wireless Infusion Pumps

141

Client Rssi.................................. -80 dBm Client Mid Rssi.............................. -80 dBm

Load Balancing Denial....................................... 3 count Window....................................... 5 clients

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

Coverage Data Data......................................... -90 dBm Voice........................................ -90 dBm Minimum Client Level......................... 2 clients Exception Level.............................. 25 % DCA Channel List................................. 1,6,11 DCA Bandwidth.................................... 20 DCA Foreign AP Contribution...................... enabled

802.11n MCS Rates MCS-00 Rate.................................. enabled MCS-01 Rate.................................. enabled MCS-02 Rate.................................. enabled MCS-03 Rate.................................. enabled MCS-04 Rate.................................. enabled MCS-05 Rate.................................. enabled MCS-06 Rate.................................. enabled MCS-07 Rate.................................. enabled MCS-08 Rate.................................. enabled MCS-09 Rate.................................. enabled MCS-10 Rate.................................. enabled MCS-11 Rate.................................. enabled MCS-12 Rate.................................. enabled MCS-13 Rate.................................. enabled MCS-14 Rate.................................. enabled

NIST SP 1800-8C: Securing Wireless Infusion Pumps

142

MCS-15 Rate.................................. enabled MCS-16 Rate.................................. enabled MCS-17 Rate.................................. enabled MCS-18 Rate.................................. enabled MCS-19 Rate.................................. enabled MCS-20 Rate.................................. enabled MCS-21 Rate.................................. enabled

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

MCS-22 Rate.................................. enabled MCS-23 Rate.................................. enabled MCS-24 Rate.................................. enabled MCS-25 Rate.................................. enabled MCS-26 Rate.................................. enabled MCS-27 Rate.................................. enabled MCS-28 Rate.................................. enabled MCS-29 Rate.................................. enabled MCS-30 Rate.................................. enabled MCS-31 Rate.................................. enabled Client Network Preference....................... default

RF Profile name................................ Typical-Client-Density-802.11a Description...................................... <none> AP Group Name.................................... <none> Radio policy..................................... 5 GHz 11n-client-only.................................. disabled Transmit Power Threshold v1...................... -70 dBm Transmit Power Threshold v2...................... -67 dBm Min Transmit Power............................... -10 dBm Max Transmit Power............................... 30 dBm 802.11a Operational Rates 802.11a 6M Rate.............................. Mandatory 802.11a 9M Rate.............................. Supported 802.11a 12M Rate............................. Mandatory

NIST SP 1800-8C: Securing Wireless Infusion Pumps

143

802.11a 18M Rate............................. Supported 802.11a 24M Rate............................. Mandatory 802.11a 36M Rate............................. Supported 802.11a 48M Rate............................. Supported 802.11a 54M Rate............................. Supported Max Clients...................................... 200

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

WLAN ID

Max Clients

-------

-------

1

600

2

600

Trap Threshold Clients...................................... 12 clients Interference................................. 10 % Noise........................................ -70 dBm Utilization.................................. 80 % Multicast Data Rate.............................. 0 Rx Sop Threshold................................. AUTO Cca Threshold.................................... 0 dBm Slot Admin State:................................ Enabled

Band Select Probe Response............................... Disabled Cycle Count.................................. 2 cycles Cycle Threshold.............................. 200 milliseconds Expire Suppression........................... 20 seconds Expire Dual Band............................. 60 seconds Client Rssi.................................. -80 dBm Client Mid Rssi.............................. -80 dBm

Load Balancing

NIST SP 1800-8C: Securing Wireless Infusion Pumps

144

Denial....................................... 3 count Window....................................... 5 clients

Coverage Data Data......................................... -80 dBm Voice........................................ -80 dBm Minimum Client Level......................... 3 clients

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

Exception Level.............................. 25 % DCA Channel List................................. 36,40,44,48,52,56,60,64,100, 104,108,112,116,120,124,128, 132,136,140,144,149,153,157, 161 DCA Bandwidth.................................... 20 DCA Foreign AP Contribution...................... enabled

802.11n MCS Rates MCS-00 Rate.................................. enabled MCS-01 Rate.................................. enabled MCS-02 Rate.................................. enabled MCS-03 Rate.................................. enabled MCS-04 Rate.................................. enabled MCS-05 Rate.................................. enabled MCS-06 Rate.................................. enabled MCS-07 Rate.................................. enabled MCS-08 Rate.................................. enabled MCS-09 Rate.................................. enabled MCS-10 Rate.................................. enabled MCS-11 Rate.................................. enabled MCS-12 Rate.................................. enabled MCS-13 Rate.................................. enabled MCS-14 Rate.................................. enabled MCS-15 Rate.................................. enabled

NIST SP 1800-8C: Securing Wireless Infusion Pumps

145

MCS-16 Rate.................................. enabled MCS-17 Rate.................................. enabled MCS-18 Rate.................................. enabled MCS-19 Rate.................................. enabled MCS-20 Rate.................................. enabled MCS-21 Rate.................................. enabled MCS-22 Rate.................................. enabled

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

MCS-23 Rate.................................. enabled MCS-24 Rate.................................. enabled MCS-25 Rate.................................. enabled MCS-26 Rate.................................. enabled MCS-27 Rate.................................. enabled MCS-28 Rate.................................. enabled MCS-29 Rate.................................. enabled MCS-30 Rate.................................. enabled MCS-31 Rate.................................. enabled Client Network Preference....................... default

RF Profile name................................ Typical-Client-Density-802.11bg Description...................................... <none> AP Group Name.................................... <none> Radio policy..................................... 2.4 GHz 11n-client-only.................................. disabled Transmit Power Threshold v1...................... -70 dBm Transmit Power Threshold v2...................... -67 dBm Min Transmit Power............................... -10 dBm Max Transmit Power............................... 30 dBm 802.11b/g Operational Rates 802.11b/g 1M Rate............................ Disabled 802.11b/g 2M Rate............................ Disabled 802.11b/g 5.5M Rate.......................... Disabled 802.11b/g 11M Rate........................... Disabled

NIST SP 1800-8C: Securing Wireless Infusion Pumps

146

802.11g 6M Rate.............................. Disabled 802.11g 9M Rate.............................. Supported 802.11g 12M Rate............................. Mandatory 802.11g 18M Rate............................. Supported 802.11g 24M Rate............................. Supported 802.11g 36M Rate............................. Supported 802.11g 48M Rate............................. Supported

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

802.11g 54M Rate............................. Supported Max Clients...................................... 200

WLAN ID

Max Clients

-------

-------

1

600

2

600

Trap Threshold Clients...................................... 12 clients Interference................................. 10 % Noise........................................ -70 dBm Utilization.................................. 80 % Multicast Data Rate.............................. 0 Rx Sop Threshold................................. AUTO Cca Threshold.................................... 0 dBm Slot Admin State:................................ Enabled

Band Select Probe Response............................... Disabled Cycle Count.................................. 2 cycles Cycle Threshold.............................. 200 milliseconds Expire Suppression........................... 20 seconds Expire Dual Band............................. 60 seconds Client Rssi.................................. -80 dBm

NIST SP 1800-8C: Securing Wireless Infusion Pumps

147

Client Mid Rssi.............................. -80 dBm

Load Balancing Denial....................................... 3 count Window....................................... 5 clients

Coverage Data

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

Data......................................... -80 dBm Voice........................................ -80 dBm Minimum Client Level......................... 3 clients Exception Level.............................. 25 % DCA Channel List................................. 1,6,11 DCA Bandwidth.................................... 20 DCA Foreign AP Contribution...................... enabled

802.11n MCS Rates MCS-00 Rate.................................. enabled MCS-01 Rate.................................. enabled MCS-02 Rate.................................. enabled MCS-03 Rate.................................. enabled MCS-04 Rate.................................. enabled MCS-05 Rate.................................. enabled MCS-06 Rate.................................. enabled MCS-07 Rate.................................. enabled MCS-08 Rate.................................. enabled MCS-09 Rate.................................. enabled MCS-10 Rate.................................. enabled MCS-11 Rate.................................. enabled MCS-12 Rate.................................. enabled MCS-13 Rate.................................. enabled MCS-14 Rate.................................. enabled MCS-15 Rate.................................. enabled

NIST SP 1800-8C: Securing Wireless Infusion Pumps

148

MCS-16 Rate.................................. enabled MCS-17 Rate.................................. enabled MCS-18 Rate.................................. enabled MCS-19 Rate.................................. enabled MCS-20 Rate.................................. enabled MCS-21 Rate.................................. enabled MCS-22 Rate.................................. enabled

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

MCS-23 Rate.................................. enabled MCS-24 Rate.................................. enabled MCS-25 Rate.................................. enabled MCS-26 Rate.................................. enabled MCS-27 Rate.................................. enabled MCS-28 Rate.................................. enabled MCS-29 Rate.................................. enabled MCS-30 Rate.................................. enabled MCS-31 Rate.................................. enabled Client Network Preference....................... default

AP Config Cisco AP Identifier.............................. 3 Cisco AP Name.................................... AP78da.6ee0.08ec Country code..................................... US

- United States

Regulatory Domain allowed by Country............. 802.11bg:-A AP Country code.................................. US

802.11a:-AB

- United States

AP Regulatory Domain............................. -A Switch Port Number .............................. 1 MAC Address...................................... 78:da:6e:e0:08:ec IP Address Configuration......................... DHCP IP Address....................................... 192.168.250.10 IP NetMask....................................... 255.255.255.0 Gateway IP Addr.................................. 192.168.250.1 NAT External IP Address.......................... None

NIST SP 1800-8C: Securing Wireless Infusion Pumps

149

CAPWAP Path MTU.................................. 1485 DHCP Release Override............................ Disabled Telnet State..................................... Globally Disabled Ssh State........................................ Globally Disabled Cisco AP Location................................ default location Cisco AP Floor Label............................. 0 Cisco AP Group Name.............................. default-group

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

Primary Cisco Switch Name........................ Primary Cisco Switch IP Address.................. Not Configured Secondary Cisco Switch Name...................... Secondary Cisco Switch IP Address................ Not Configured Tertiary Cisco Switch Name....................... Tertiary Cisco Switch IP Address................. Not Configured Administrative State ............................ ADMIN_ENABLED Operation State ................................. REGISTERED Mirroring Mode .................................. Disabled AP Mode ......................................... FlexConnect Public Safety ................................... Disabled ATF Mode: ....................................... Disable AP SubMode ...................................... Not Configured Rogue Detection ................................. Enabled AP Vlan Trunking ................................ Disabled Remote AP Debug ................................. Disabled Logging trap severity level ..................... informational Logging syslog facility ......................... kern S/W

Version .................................... 8.2.111.0

Boot

Version ................................... 15.2.2.0

Mini IOS Version ................................ 7.5.1.73 Stats Reporting Period .......................... 180 Stats Collection Mode ........................... normal LED State........................................ Enabled PoE Pre-Standard Switch.......................... Disabled

NIST SP 1800-8C: Securing Wireless Infusion Pumps

150

PoE Power Injector MAC Addr...................... Disabled Power Type/Mode.................................. PoE/Full Power Number Of Slots.................................. 2 AP Model......................................... AIR-CAP1602I-A-K9 AP Image......................................... C1600-K9W8-M IOS Version...................................... 15.3(3)JC2$ Reset Button..................................... Enabled

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

AP Serial Number................................. FGL1748W52Y AP Certificate Type.............................. Manufacture Installed AP Lag Status ................................... Disable Native Vlan Inheritance: ........................ AP FlexConnect Vlan mode :.......................... Disabled FlexConnect Group................................ Not a member of any group Group VLAN ACL Mappings

Group VLAN Name to Id Mappings Template in Modified State - apply it to see mappings

AP-Specific FlexConnect Policy ACLs : L2Acl Configuration ............................. Not Available FlexConnect Local-Split ACLs :

WLAN ID

PROFILE NAME

ACL

TYPE

-------

--------------------------------

---------------------------------

------

Flexconnect Central-Dhcp Values :

WLAN ID Nat-Pat

PROFILE NAME Type

------- ------------------------------------------

NIST SP 1800-8C: Securing Wireless Infusion Pumps

Central-Dhcp

DNS Override

--------------

--------------

----

151

1 False

IP_Dev No Encryption Wlan

False

False

Flex AVC visibility Configurations..............

WlanId PROFILE NAME profile

Inherit-level Visibility

Flex Avc-

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

------- -------------------------------- ------------- ---------- ------------------------------1

IP_Dev No Encryption

wlan-spec

disable

none

FlexConnect Backup Auth Radius Servers : Primary Radius Server........................... Disabled Secondary Radius Server......................... Disabled AP User Mode..................................... AUTOMATIC AP User Name..................................... Cisco AP Dot1x User Mode............................... Not Configured AP Dot1x User Name............................... Not Configured Cisco AP system logging host..................... 255.255.255.255 AP Core Dump Config.............................. Disabled AP Up Time....................................... 2 days, 22 h 22 m 20 s AP LWAPP Up Time................................. 2 days, 22 h 18 m 20 s Join Date and Time............................... Mon Aug 15 21:47:06 2016 Join Taken Time.................................. 0 days, 00 h 03 m 59 s

Attributes for Slot

0

Radio Type................................... RADIO_TYPE_80211n-2.4 Administrative State ........................ ADMIN_ENABLED Operation State ............................. UP Mesh Radio Role ............................. ACCESS Radio Role .................................. Client Serving (Remote) CellId ...................................... 0

NIST SP 1800-8C: Securing Wireless Infusion Pumps

152

Station Configuration Configuration ............................. AUTOMATIC Number Of WLANs ........................... 1 Medium Occupancy Limit .................... 100 CFP Period ................................ 4 CFP MaxDuration ........................... 60 BSSID ..................................... 5c:a4:8a:be:ca:90

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

Operation Rate Set 1000 Kilo Bits........................... MANDATORY 2000 Kilo Bits........................... MANDATORY 5500 Kilo Bits........................... MANDATORY 11000 Kilo Bits.......................... MANDATORY 6000 Kilo Bits........................... SUPPORTED 9000 Kilo Bits........................... SUPPORTED 12000 Kilo Bits.......................... SUPPORTED 18000 Kilo Bits.......................... SUPPORTED 24000 Kilo Bits.......................... SUPPORTED 36000 Kilo Bits.......................... SUPPORTED 48000 Kilo Bits.......................... SUPPORTED 54000 Kilo Bits.......................... SUPPORTED MCS Set MCS 0.................................... SUPPORTED MCS 1.................................... SUPPORTED MCS 2.................................... SUPPORTED MCS 3.................................... SUPPORTED MCS 4.................................... SUPPORTED MCS 5.................................... SUPPORTED MCS 6.................................... SUPPORTED MCS 7.................................... SUPPORTED MCS 8.................................... SUPPORTED MCS 9.................................... SUPPORTED MCS 10................................... SUPPORTED

NIST SP 1800-8C: Securing Wireless Infusion Pumps

153

MCS 11................................... SUPPORTED MCS 12................................... SUPPORTED MCS 13................................... SUPPORTED MCS 14................................... SUPPORTED MCS 15................................... SUPPORTED MCS 16................................... DISABLED MCS 17................................... DISABLED

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

MCS 18................................... DISABLED MCS 19................................... DISABLED MCS 20................................... DISABLED MCS 21................................... DISABLED MCS 22................................... DISABLED MCS 23................................... DISABLED MCS 24................................... DISABLED MCS 25................................... DISABLED MCS 26................................... DISABLED MCS 27................................... DISABLED MCS 28................................... DISABLED MCS 29................................... DISABLED MCS 30................................... DISABLED MCS 31................................... DISABLED Beacon Period ............................. 100 Fragmentation Threshold ................... 2346 Multi Domain Capability Implemented ....... TRUE Multi Domain Capability Enabled ........... TRUE Country String ............................ US

Multi Domain Capability Configuration ............................. AUTOMATIC First Chan Num ............................ 1 Number Of Channels ........................ 11

NIST SP 1800-8C: Securing Wireless Infusion Pumps

154

MAC Operation Parameters Configuration ............................. AUTOMATIC Fragmentation Threshold ................... 2346 Packet Retry Limit ........................ 64

Tx Power Num Of Supported Power Levels ............. 6

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

Tx Power Level 1 .......................... 22 dBm Tx Power Level 2 .......................... 19 dBm Tx Power Level 3 .......................... 16 dBm Tx Power Level 4 .......................... 13 dBm Tx Power Level 5 .......................... 10 dBm Tx Power Level 6 .......................... 7 dBm Tx Power Configuration .................... AUTOMATIC Current Tx Power Level .................... 1 Tx Power Assigned By ...................... DTPC

Phy OFDM parameters Configuration ............................. AUTOMATIC Current Channel ........................... 11 Channel Assigned By ....................... DCA Extension Channel ......................... NONE Channel Width.............................. 20 Mhz Allowed Channel List....................... 1,2,3,4,5,6,7,8,9,10,11 TI Threshold .............................. -50 DCA Channel List........................... Global Legacy Tx Beamforming Configuration ....... CUSTOMIZED Legacy Tx Beamforming ..................... ENABLED Antenna Type............................... INTERNAL_ANTENNA Internal Antenna Gain (in .5 dBi units).... 8 Diversity.................................. DIVERSITY_ENABLED 802.11n Antennas

NIST SP 1800-8C: Securing Wireless Infusion Pumps

155

A....................................... ENABLED B....................................... ENABLED C....................................... ENABLED

Performance Profile Parameters Configuration ............................. AUTOMATIC Interference threshold..................... 10 %

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

Noise threshold............................

-70 dBm

RF utilization threshold................... 80 % Data-rate threshold........................ 1000000 bps Client threshold........................... 12 clients Coverage SNR threshold..................... 12 dB Coverage exception level................... 25 % Client minimum exception level............. 3 clients Rogue Containment Information Containment Count............................ 0

CleanAir Management Information CleanAir Capable......................... Yes CleanAir Management Administration St.... Enabled CleanAir Management Operation State...... Down Rapid Update Mode........................ Off Spectrum Expert connection............... Enabled CleanAir NSI Key....................... C44B365F4CFF338BE94B85633D98944B Spectrum Expert Connections counter.... 0 CleanAir Sensor State.................... Configured

Radio Extended Configurations Beacon period.............................. 100 milliseconds Beacon range............................... AUTO Multicast buffer........................... AUTO Multicast data-rate........................ AUTO

NIST SP 1800-8C: Securing Wireless Infusion Pumps

156

RX SOP threshold........................... AUTO CCA threshold.............................. AUTO

Attributes for Slot

1

Radio Type................................... RADIO_TYPE_80211n-5 Radio Subband................................ RADIO_SUBBAND_ALL Administrative State ........................ ADMIN_ENABLED

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

Operation State ............................. UP Mesh Radio Role ............................. ACCESS Radio Role .................................. Client Serving (Remote) CellId ...................................... 0

Station Configuration Configuration ............................. AUTOMATIC Number Of WLANs ........................... 1 Medium Occupancy Limit .................... 100 CFP Period ................................ 4 CFP MaxDuration ........................... 60 BSSID ..................................... 5c:a4:8a:be:ca:90 Operation Rate Set 6000 Kilo Bits........................... MANDATORY 9000 Kilo Bits........................... SUPPORTED 12000 Kilo Bits.......................... MANDATORY 18000 Kilo Bits.......................... SUPPORTED 24000 Kilo Bits.......................... MANDATORY 36000 Kilo Bits.......................... SUPPORTED 48000 Kilo Bits.......................... SUPPORTED 54000 Kilo Bits.......................... SUPPORTED MCS Set MCS 0.................................... SUPPORTED MCS 1.................................... SUPPORTED MCS 2.................................... SUPPORTED

NIST SP 1800-8C: Securing Wireless Infusion Pumps

157

MCS 3.................................... SUPPORTED MCS 4.................................... SUPPORTED MCS 5.................................... SUPPORTED MCS 6.................................... SUPPORTED MCS 7.................................... SUPPORTED MCS 8.................................... SUPPORTED MCS 9.................................... SUPPORTED

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

MCS 10................................... SUPPORTED MCS 11................................... SUPPORTED MCS 12................................... SUPPORTED MCS 13................................... SUPPORTED MCS 14................................... SUPPORTED MCS 15................................... SUPPORTED MCS 16................................... DISABLED MCS 17................................... DISABLED MCS 18................................... DISABLED MCS 19................................... DISABLED MCS 20................................... DISABLED MCS 21................................... DISABLED MCS 22................................... DISABLED MCS 23................................... DISABLED MCS 24................................... DISABLED MCS 25................................... DISABLED MCS 26................................... DISABLED MCS 27................................... DISABLED MCS 28................................... DISABLED MCS 29................................... DISABLED MCS 30................................... DISABLED MCS 31................................... DISABLED Beacon Period ............................. 100 Fragmentation Threshold ................... 2346 Multi Domain Capability Implemented ....... TRUE

NIST SP 1800-8C: Securing Wireless Infusion Pumps

158

Multi Domain Capability Enabled ........... TRUE Country String ............................ US

Multi Domain Capability Configuration ............................. AUTOMATIC First Chan Num ............................ 36 Number Of Channels ........................ 21

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

MAC Operation Parameters Configuration ............................. AUTOMATIC Fragmentation Threshold ................... 2346 Packet Retry Limit ........................ 64 Tx Power Num Of Supported Power Levels ............. 6 Tx Power Level 1 .......................... 22 dBm Tx Power Level 2 .......................... 19 dBm Tx Power Level 3 .......................... 16 dBm Tx Power Level 4 .......................... 13 dBm Tx Power Level 5 .......................... 10 dBm Tx Power Level 6 .......................... 7 dBm Tx Power Configuration .................... AUTOMATIC Current Tx Power Level .................... 1 Tx Power Assigned By ...................... DTPC

Phy OFDM parameters Configuration ............................. AUTOMATIC Current Channel ........................... 149 Channel Assigned By ....................... DCA Extension Channel ......................... NONE Channel Width.............................. 20 Mhz Allowed Channel List....................... 36,40,44,48,52,56,60,64,100, ......................................... 104,108,112,116,132,136,140,

NIST SP 1800-8C: Securing Wireless Infusion Pumps

159

......................................... 149,153,157,161,165 TI Threshold .............................. -50 DCA Channel List........................... Global Legacy Tx Beamforming Configuration ....... CUSTOMIZED Legacy Tx Beamforming ..................... ENABLED Antenna Type............................... INTERNAL_ANTENNA Internal Antenna Gain (in .5 dBi units).... 8

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

Diversity.................................. DIVERSITY_ENABLED 802.11n Antennas A....................................... ENABLED B....................................... ENABLED C....................................... ENABLED

Performance Profile Parameters Configuration ............................. AUTOMATIC Interference threshold..................... 10 % Noise threshold............................

-70 dBm

RF utilization threshold................... 80 % Data-rate threshold........................ 1000000 bps Client threshold........................... 12 clients Coverage SNR threshold..................... 16 dB Coverage exception level................... 25 % Client minimum exception level............. 3 clients Rogue Containment Information Containment Count............................ 0

CleanAir Management Information CleanAir Capable......................... Yes CleanAir Management Administration St.... Enabled CleanAir Management Operation State...... Down Rapid Update Mode........................ Off Spectrum Expert connection............... Enabled

NIST SP 1800-8C: Securing Wireless Infusion Pumps

160

CleanAir NSI Key....................... C44B365F4CFF338BE94B85633D98944B Spectrum Expert Connections counter.... 0 CleanAir Sensor State.................... Configured

Radio Extended Configurations Beacon period.............................. 100 milliseconds Beacon range............................... AUTO

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

Multicast buffer........................... AUTO Multicast data-rate........................ AUTO RX SOP threshold........................... AUTO CCA threshold.............................. AUTO

Cisco AP Identifier.............................. 4 Cisco AP Name.................................... AP24e9.b34b.f1ed Country code..................................... US

- United States

Regulatory Domain allowed by Country............. 802.11bg:-A AP Country code.................................. US

802.11a:-AB

- United States

AP Regulatory Domain............................. -A Switch Port Number .............................. 1 MAC Address...................................... 24:e9:b3:4b:f1:ed IP Address Configuration......................... DHCP IP Address....................................... 192.168.250.11 IP NetMask....................................... 255.255.255.0 Gateway IP Addr.................................. 192.168.250.1 NAT External IP Address.......................... None CAPWAP Path MTU.................................. 1485 DHCP Release Override............................ Disabled Telnet State..................................... Globally Disabled Ssh State........................................ Globally Disabled Cisco AP Location................................ default location Cisco AP Floor Label............................. 0 Cisco AP Group Name.............................. default-group

NIST SP 1800-8C: Securing Wireless Infusion Pumps

161

Primary Cisco Switch Name........................ Primary Cisco Switch IP Address.................. Not Configured Secondary Cisco Switch Name...................... Secondary Cisco Switch IP Address................ Not Configured Tertiary Cisco Switch Name....................... Tertiary Cisco Switch IP Address................. Not Configured Administrative State ............................ ADMIN_ENABLED

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

Operation State ................................. REGISTERED Mirroring Mode .................................. Disabled AP Mode ......................................... FlexConnect Public Safety ................................... Disabled ATF Mode: ....................................... Disable AP SubMode ...................................... Not Configured Rogue Detection ................................. Enabled AP Vlan Trunking ................................ Disabled Remote AP Debug ................................. Disabled Logging trap severity level ..................... emergencies Logging syslog facility ......................... system S/W

Version .................................... 8.2.111.0

Boot

Version ................................... 15.2.2.0

Mini IOS Version ................................ 7.5.1.73 Stats Reporting Period .......................... 180 Stats Collection Mode ........................... normal LED State........................................ Enabled PoE Pre-Standard Switch.......................... Disabled PoE Power Injector MAC Addr...................... Disabled Power Type/Mode.................................. PoE/Full Power Number Of Slots.................................. 2 AP Model......................................... AIR-CAP1602I-A-K9 AP Image......................................... C1600-K9W8-M IOS Version...................................... 15.3(3)JC2$ Reset Button..................................... Enabled

NIST SP 1800-8C: Securing Wireless Infusion Pumps

162

AP Serial Number................................. FGL1748W52S AP Certificate Type.............................. Manufacture Installed AP Lag Status ................................... Disable Native Vlan Inheritance: ........................ Group FlexConnect Vlan mode :.......................... Disabled FlexConnect Group................................ Not a member of any group Group VLAN ACL Mappings

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

Group VLAN Name to Id Mappings Template in Modified State - apply it to see mappings

AP-Specific FlexConnect Policy ACLs : L2Acl Configuration ............................. Not Available FlexConnect Local-Split ACLs :

WLAN ID

PROFILE NAME

ACL

TYPE

-------

--------------------------------

---------------------------------

------

Flexconnect Central-Dhcp Values :

WLAN ID Nat-Pat

PROFILE NAME Type

------- -----------------------------------------1 False

Central-Dhcp

DNS Override

--------------

--------------

False

False

IP_Dev No Encryption Wlan

----

Flex AVC visibility Configurations..............

WlanId PROFILE NAME profile

Inherit-level Visibility

Flex Avc-

------- -------------------------------- ------------- ---------- -------------------------------

NIST SP 1800-8C: Securing Wireless Infusion Pumps

163

1

IP_Dev No Encryption

wlan-spec

disable

none

FlexConnect Backup Auth Radius Servers : Primary Radius Server........................... Disabled Secondary Radius Server......................... Disabled AP User Mode..................................... AUTOMATIC AP User Name..................................... Cisco

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

AP Dot1x User Mode............................... Not Configured AP Dot1x User Name............................... Not Configured Cisco AP system logging host..................... 255.255.255.255 AP Core Dump Config.............................. Disabled AP Up Time....................................... 2 days, 22 h 22 m 16 s AP LWAPP Up Time................................. 2 days, 22 h 18 m 14 s Join Date and Time............................... Mon Aug 15 21:47:12 2016 Join Taken Time.................................. 0 days, 00 h 04 m 01 s

Attributes for Slot

0

Radio Type................................... RADIO_TYPE_80211n-2.4 Administrative State ........................ ADMIN_ENABLED Operation State ............................. UP Mesh Radio Role ............................. ACCESS Radio Role .................................. Client Serving (Remote) CellId ...................................... 0

Station Configuration Configuration ............................. AUTOMATIC Number Of WLANs ........................... 1 Medium Occupancy Limit .................... 100 CFP Period ................................ 4 CFP MaxDuration ........................... 60 BSSID ..................................... 1c:1d:86:31:e5:50 Operation Rate Set

NIST SP 1800-8C: Securing Wireless Infusion Pumps

164

1000 Kilo Bits........................... MANDATORY 2000 Kilo Bits........................... MANDATORY 5500 Kilo Bits........................... MANDATORY 11000 Kilo Bits.......................... MANDATORY 6000 Kilo Bits........................... SUPPORTED 9000 Kilo Bits........................... SUPPORTED 12000 Kilo Bits.......................... SUPPORTED

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

18000 Kilo Bits.......................... SUPPORTED 24000 Kilo Bits.......................... SUPPORTED 36000 Kilo Bits.......................... SUPPORTED 48000 Kilo Bits.......................... SUPPORTED 54000 Kilo Bits.......................... SUPPORTED MCS Set MCS 0.................................... SUPPORTED MCS 1.................................... SUPPORTED MCS 2.................................... SUPPORTED MCS 3.................................... SUPPORTED MCS 4.................................... SUPPORTED MCS 5.................................... SUPPORTED MCS 6.................................... SUPPORTED MCS 7.................................... SUPPORTED MCS 8.................................... SUPPORTED MCS 9.................................... SUPPORTED MCS 10................................... SUPPORTED MCS 11................................... SUPPORTED MCS 12................................... SUPPORTED MCS 13................................... SUPPORTED MCS 14................................... SUPPORTED MCS 15................................... SUPPORTED MCS 16................................... DISABLED MCS 17................................... DISABLED MCS 18................................... DISABLED

NIST SP 1800-8C: Securing Wireless Infusion Pumps

165

MCS 19................................... DISABLED MCS 20................................... DISABLED MCS 21................................... DISABLED MCS 22................................... DISABLED MCS 23................................... DISABLED MCS 24................................... DISABLED MCS 25................................... DISABLED

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

MCS 26................................... DISABLED MCS 27................................... DISABLED MCS 28................................... DISABLED MCS 29................................... DISABLED MCS 30................................... DISABLED MCS 31................................... DISABLED Beacon Period ............................. 100 Fragmentation Threshold ................... 2346 Multi Domain Capability Implemented ....... TRUE Multi Domain Capability Enabled ........... TRUE Country String ............................ US

Multi Domain Capability Configuration ............................. AUTOMATIC First Chan Num ............................ 1 Number Of Channels ........................ 11

MAC Operation Parameters Configuration ............................. AUTOMATIC Fragmentation Threshold ................... 2346 Packet Retry Limit ........................ 64

Tx Power Num Of Supported Power Levels ............. 6 Tx Power Level 1 .......................... 22 dBm

NIST SP 1800-8C: Securing Wireless Infusion Pumps

166

Tx Power Level 2 .......................... 19 dBm Tx Power Level 3 .......................... 16 dBm Tx Power Level 4 .......................... 13 dBm Tx Power Level 5 .......................... 10 dBm Tx Power Level 6 .......................... 7 dBm Tx Power Configuration .................... AUTOMATIC Current Tx Power Level .................... 1

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

Tx Power Assigned By ...................... DTPC

Phy OFDM parameters Configuration ............................. AUTOMATIC Current Channel ........................... 11 Channel Assigned By ....................... DCA Extension Channel ......................... NONE Channel Width.............................. 20 Mhz Allowed Channel List....................... 1,2,3,4,5,6,7,8,9,10,11 TI Threshold .............................. -50 DCA Channel List........................... Global Legacy Tx Beamforming Configuration ....... CUSTOMIZED Legacy Tx Beamforming ..................... ENABLED Antenna Type............................... INTERNAL_ANTENNA Internal Antenna Gain (in .5 dBi units).... 8 Diversity.................................. DIVERSITY_ENABLED 802.11n Antennas A....................................... ENABLED B....................................... ENABLED C....................................... ENABLED

Performance Profile Parameters Configuration ............................. AUTOMATIC Interference threshold..................... 10 % Noise threshold............................

NIST SP 1800-8C: Securing Wireless Infusion Pumps

-70 dBm

167

RF utilization threshold................... 80 % Data-rate threshold........................ 1000000 bps Client threshold........................... 12 clients Coverage SNR threshold..................... 12 dB Coverage exception level................... 25 % Client minimum exception level............. 3 clients Rogue Containment Information

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

Containment Count............................ 0

CleanAir Management Information CleanAir Capable......................... Yes CleanAir Management Administration St.... Disabled CleanAir Management Operation State...... Down Rapid Update Mode........................ Off Spectrum Expert connection............... Enabled CleanAir NSI Key....................... 8994C2313910BF9588C6693603B8F970 Spectrum Expert Connections counter.... 0 CleanAir Sensor State.................... Configured

Radio Extended Configurations Beacon period.............................. 100 milliseconds Beacon range............................... AUTO Multicast buffer........................... AUTO Multicast data-rate........................ AUTO RX SOP threshold........................... AUTO CCA threshold.............................. AUTO

Attributes for Slot

1

Radio Type................................... RADIO_TYPE_80211n-5 Radio Subband................................ RADIO_SUBBAND_ALL Administrative State ........................ ADMIN_ENABLED Operation State ............................. UP

NIST SP 1800-8C: Securing Wireless Infusion Pumps

168

Mesh Radio Role ............................. ACCESS Radio Role .................................. Client Serving (Remote) CellId ...................................... 0

Station Configuration Configuration ............................. AUTOMATIC Number Of WLANs ........................... 1

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

Medium Occupancy Limit .................... 100 CFP Period ................................ 4 CFP MaxDuration ........................... 60 BSSID ..................................... 1c:1d:86:31:e5:50 Operation Rate Set 6000 Kilo Bits........................... MANDATORY 9000 Kilo Bits........................... SUPPORTED 12000 Kilo Bits.......................... MANDATORY 18000 Kilo Bits.......................... SUPPORTED 24000 Kilo Bits.......................... MANDATORY 36000 Kilo Bits.......................... SUPPORTED 48000 Kilo Bits.......................... SUPPORTED 54000 Kilo Bits.......................... SUPPORTED MCS Set MCS 0.................................... SUPPORTED MCS 1.................................... SUPPORTED MCS 2.................................... SUPPORTED MCS 3.................................... SUPPORTED MCS 4.................................... SUPPORTED MCS 5.................................... SUPPORTED MCS 6.................................... SUPPORTED MCS 7.................................... SUPPORTED MCS 8.................................... SUPPORTED MCS 9.................................... SUPPORTED MCS 10................................... SUPPORTED

NIST SP 1800-8C: Securing Wireless Infusion Pumps

169

MCS 11................................... SUPPORTED MCS 12................................... SUPPORTED MCS 13................................... SUPPORTED MCS 14................................... SUPPORTED MCS 15................................... SUPPORTED MCS 16................................... DISABLED MCS 17................................... DISABLED

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

MCS 18................................... DISABLED MCS 19................................... DISABLED MCS 20................................... DISABLED MCS 21................................... DISABLED MCS 22................................... DISABLED MCS 23................................... DISABLED MCS 24................................... DISABLED MCS 25................................... DISABLED MCS 26................................... DISABLED MCS 27................................... DISABLED MCS 28................................... DISABLED MCS 29................................... DISABLED MCS 30................................... DISABLED MCS 31................................... DISABLED Beacon Period ............................. 100 Fragmentation Threshold ................... 2346 Multi Domain Capability Implemented ....... TRUE Multi Domain Capability Enabled ........... TRUE Country String ............................ US

Multi Domain Capability Configuration ............................. AUTOMATIC First Chan Num ............................ 36 Number Of Channels ........................ 21

NIST SP 1800-8C: Securing Wireless Infusion Pumps

170

MAC Operation Parameters Configuration ............................. AUTOMATIC Fragmentation Threshold ................... 2346 Packet Retry Limit ........................ 64

Tx Power Num Of Supported Power Levels ............. 6

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

Tx Power Level 1 .......................... 22 dBm Tx Power Level 2 .......................... 19 dBm Tx Power Level 3 .......................... 16 dBm Tx Power Level 4 .......................... 13 dBm Tx Power Level 5 .......................... 10 dBm Tx Power Level 6 .......................... 7 dBm Tx Power Configuration .................... AUTOMATIC Current Tx Power Level .................... 1 Tx Power Assigned By ...................... DTPC

Phy OFDM parameters Configuration ............................. AUTOMATIC Current Channel ........................... 48 Channel Assigned By ....................... DCA Extension Channel ......................... NONE Channel Width.............................. 20 Mhz Allowed Channel List....................... 36,40,44,48,52,56,60,64,100, ......................................... 104,108,112,116,132,136,140, ......................................... 149,153,157,161,165 TI Threshold .............................. -50 DCA Channel List........................... Global Legacy Tx Beamforming Configuration ....... CUSTOMIZED Legacy Tx Beamforming ..................... ENABLED Antenna Type............................... INTERNAL_ANTENNA Internal Antenna Gain (in .5 dBi units).... 8

NIST SP 1800-8C: Securing Wireless Infusion Pumps

171

Diversity.................................. DIVERSITY_ENABLED 802.11n Antennas A....................................... ENABLED B....................................... ENABLED C....................................... ENABLED

Performance Profile Parameters

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

Configuration ............................. AUTOMATIC Interference threshold..................... 10 % Noise threshold............................

-70 dBm

RF utilization threshold................... 80 % Data-rate threshold........................ 1000000 bps Client threshold........................... 12 clients Coverage SNR threshold..................... 16 dB Coverage exception level................... 25 % Client minimum exception level............. 3 clients Rogue Containment Information Containment Count............................ 0

CleanAir Management Information CleanAir Capable......................... Yes CleanAir Management Administration St.... Disabled CleanAir Management Operation State...... Down Rapid Update Mode........................ Off Spectrum Expert connection............... Enabled CleanAir NSI Key....................... 8994C2313910BF9588C6693603B8F970 Spectrum Expert Connections counter.... 0 CleanAir Sensor State.................... Configured

Radio Extended Configurations Beacon period.............................. 100 milliseconds Beacon range............................... AUTO

NIST SP 1800-8C: Securing Wireless Infusion Pumps

172

Multicast buffer........................... AUTO Multicast data-rate........................ AUTO RX SOP threshold........................... AUTO CCA threshold.............................. AUTO

AP Airewave Director Configuration AP does not have the 802.11-abgn radio.

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

Number Of Slots.................................. 2 AP Name.......................................... AP78da.6ee0.08ec MAC Address...................................... 78:da:6e:e0:08:ec Slot ID........................................ 0 Radio Type..................................... RADIO_TYPE_80211b/g Sub-band Type.................................. All Noise Information Noise Profile................................ PASSED Interference Information Interference Profile......................... PASSED Rogue Histogram (20) ............................................. Load Information Load Profile................................. PASSED Receive Utilization.......................... 0 % Transmit Utilization......................... 0 % Channel Utilization.......................... 38 % Attached Clients............................. 0 clients Coverage Information Coverage Profile............................. PASSED Failed Clients............................... 0 clients Client Signal Strengths RSSI -100 dbm................................ 0 clients RSSI

-92 dbm................................ 0 clients

RSSI

-84 dbm................................ 0 clients

NIST SP 1800-8C: Securing Wireless Infusion Pumps

173

RSSI

-76 dbm................................ 0 clients

RSSI

-68 dbm................................ 0 clients

RSSI

-60 dbm................................ 0 clients

RSSI

-52 dbm................................ 0 clients

Client Signal To Noise Ratios

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

SNR

0 dB.................................. 0 clients

SNR

5 dB.................................. 0 clients

SNR

10 dB.................................. 0 clients

SNR

15 dB.................................. 0 clients

SNR

20 dB.................................. 0 clients

SNR

25 dB.................................. 0 clients

SNR

30 dB.................................. 0 clients

SNR

35 dB.................................. 0 clients

SNR

40 dB.................................. 0 clients

SNR

45 dB.................................. 0 clients

Nearby APs Radar Information Channel Assignment Information Current Channel Average Energy............... -127 dBm Previous Channel Average Energy.............. -127 dBm Channel Change Count......................... 415 Last Channel Change Time..................... Thu Aug 18 20:01:53 2016 Recommended Best Channel..................... 11 RF Parameter Recommendations Power Level.................................. 1 RTS/CTS Threshold............................ 2347 Fragmentation Threshold...................... 2346 Antenna Pattern.............................. 0

Persistent Interference Devices Class Type

Channel

DC (%%)

RSSI (dBm)

Last Update Time

-------------------------

-------

------

----------

------------------------

NIST SP 1800-8C: Securing Wireless Infusion Pumps

174

All third party trademarks are the property of their respective owners. Number Of Slots.................................. 2 AP Name.......................................... AP78da.6ee0.08ec MAC Address...................................... 78:da:6e:e0:08:ec Slot ID........................................ 1 Radio Type..................................... RADIO_TYPE_80211a Sub-band Type.................................. All

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

Noise Information Noise Profile................................ PASSED Interference Information Interference Profile......................... PASSED Rogue Histogram (20/40/80/160) ............................................. Load Information Load Profile................................. PASSED Receive Utilization.......................... 0 % Transmit Utilization......................... 0 % Channel Utilization.......................... 1 % Attached Clients............................. 0 clients Coverage Information Coverage Profile............................. PASSED Failed Clients............................... 0 clients Client Signal Strengths RSSI -100 dbm................................ 0 clients RSSI

-92 dbm................................ 0 clients

RSSI

-84 dbm................................ 0 clients

RSSI

-76 dbm................................ 0 clients

RSSI

-68 dbm................................ 0 clients

RSSI

-60 dbm................................ 0 clients

RSSI

-52 dbm................................ 0 clients

Client Signal To Noise Ratios SNR

0 dB.................................. 0 clients

NIST SP 1800-8C: Securing Wireless Infusion Pumps

175

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

SNR

5 dB.................................. 0 clients

SNR

10 dB.................................. 0 clients

SNR

15 dB.................................. 0 clients

SNR

20 dB.................................. 0 clients

SNR

25 dB.................................. 0 clients

SNR

30 dB.................................. 0 clients

SNR

35 dB.................................. 0 clients

SNR

40 dB.................................. 0 clients

SNR

45 dB.................................. 0 clients

Nearby APs Radar Information Channel Assignment Information Current Channel Average Energy............... -127 dBm Previous Channel Average Energy.............. -127 dBm Channel Change Count......................... 417 Last Channel Change Time..................... Thu Aug 18 20:05:14 2016 Recommended Best Channel..................... 149 RF Parameter Recommendations Power Level.................................. 1 RTS/CTS Threshold............................ 2347 Fragmentation Threshold...................... 2346 Antenna Pattern.............................. 0

Persistent Interference Devices Class Type

Channel

DC (%%)

RSSI (dBm)

Last Update Time

-------------------------

-------

------

----------

------------------------

All third party trademarks are the property of their respective owners.

AP does not have the 802.11-abgn radio. Number Of Slots.................................. 2 AP Name.......................................... AP24e9.b34b.f1ed MAC Address...................................... 24:e9:b3:4b:f1:ed

NIST SP 1800-8C: Securing Wireless Infusion Pumps

176

Slot ID........................................ 0 Radio Type..................................... RADIO_TYPE_80211b/g Sub-band Type.................................. All Noise Information Noise Profile................................ PASSED Interference Information Interference Profile......................... PASSED

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

Rogue Histogram (20) ............................................. Load Information Load Profile................................. PASSED Receive Utilization.......................... 0 % Transmit Utilization......................... 0 % Channel Utilization.......................... 34 % Attached Clients............................. 1 clients Coverage Information Coverage Profile............................. PASSED Failed Clients............................... 0 clients Client Signal Strengths RSSI -100 dbm................................ 0 clients RSSI

-92 dbm................................ 0 clients

RSSI

-84 dbm................................ 0 clients

RSSI

-76 dbm................................ 0 clients

RSSI

-68 dbm................................ 0 clients

RSSI

-60 dbm................................ 0 clients

RSSI

-52 dbm................................ 1 clients

Client Signal To Noise Ratios SNR

0 dB.................................. 0 clients

SNR

5 dB.................................. 0 clients

SNR

10 dB.................................. 0 clients

SNR

15 dB.................................. 0 clients

SNR

20 dB.................................. 0 clients

NIST SP 1800-8C: Securing Wireless Infusion Pumps

177

SNR

25 dB.................................. 0 clients

SNR

30 dB.................................. 0 clients

SNR

35 dB.................................. 0 clients

SNR

40 dB.................................. 0 clients

SNR

45 dB.................................. 1 clients

Nearby APs Radar Information

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

Channel Assignment Information Current Channel Average Energy............... -127 dBm Previous Channel Average Energy.............. -127 dBm Channel Change Count......................... 415 Last Channel Change Time..................... Thu Aug 18 20:01:53 2016 Recommended Best Channel..................... 11 RF Parameter Recommendations Power Level.................................. 1 RTS/CTS Threshold............................ 2347 Fragmentation Threshold...................... 2346 Antenna Pattern.............................. 0

Persistent Interference Devices Class Type

Channel

DC (%%)

RSSI (dBm)

Last Update Time

-------------------------

-------

------

----------

------------------------

All third party trademarks are the property of their respective owners. Number Of Slots.................................. 2 AP Name.......................................... AP24e9.b34b.f1ed MAC Address...................................... 24:e9:b3:4b:f1:ed Slot ID........................................ 1 Radio Type..................................... RADIO_TYPE_80211a Sub-band Type.................................. All Noise Information Noise Profile................................ PASSED Interference Information

NIST SP 1800-8C: Securing Wireless Infusion Pumps

178

Interference Profile......................... PASSED Rogue Histogram (20/40/80/160) ............................................. Load Information Load Profile................................. PASSED Receive Utilization.......................... 0 % Transmit Utilization......................... 0 %

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

Channel Utilization.......................... 0 % Attached Clients............................. 0 clients Coverage Information Coverage Profile............................. PASSED Failed Clients............................... 0 clients Client Signal Strengths RSSI -100 dbm................................ 0 clients RSSI

-92 dbm................................ 0 clients

RSSI

-84 dbm................................ 0 clients

RSSI

-76 dbm................................ 0 clients

RSSI

-68 dbm................................ 0 clients

RSSI

-60 dbm................................ 0 clients

RSSI

-52 dbm................................ 0 clients

Client Signal To Noise Ratios SNR

0 dB.................................. 0 clients

SNR

5 dB.................................. 0 clients

SNR

10 dB.................................. 0 clients

SNR

15 dB.................................. 0 clients

SNR

20 dB.................................. 0 clients

SNR

25 dB.................................. 0 clients

SNR

30 dB.................................. 0 clients

SNR

35 dB.................................. 0 clients

SNR

40 dB.................................. 0 clients

SNR

45 dB.................................. 0 clients

Nearby APs

NIST SP 1800-8C: Securing Wireless Infusion Pumps

179

Radar Information Channel Assignment Information Current Channel Average Energy............... -127 dBm Previous Channel Average Energy.............. -127 dBm Channel Change Count......................... 417 Last Channel Change Time..................... Thu Aug 18 20:05:14 2016 Recommended Best Channel..................... 48

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

RF Parameter Recommendations Power Level.................................. 1 RTS/CTS Threshold............................ 2347 Fragmentation Threshold...................... 2346 Antenna Pattern.............................. 0

Persistent Interference Devices Class Type

Channel

DC (%%)

RSSI (dBm)

Last Update Time

-------------------------

-------

------

----------

------------------------

All third party trademarks are the property of their respective owners.

802.11a Configuration 802.11a Network.................................. Enabled 11acSupport...................................... Enabled 11nSupport....................................... Enabled 802.11a Low Band........................... Enabled 802.11a Mid Band........................... Enabled 802.11a High Band.......................... Enabled 802.11a Operational Rates 802.11a 6M Rate.............................. Mandatory 802.11a 9M Rate.............................. Supported 802.11a 12M Rate............................. Mandatory 802.11a 18M Rate............................. Supported 802.11a 24M Rate............................. Mandatory 802.11a 36M Rate............................. Supported

NIST SP 1800-8C: Securing Wireless Infusion Pumps

180

802.11a 48M Rate............................. Supported 802.11a 54M Rate............................. Supported 802.11n MCS Settings: MCS 0........................................ Supported MCS 1........................................ Supported MCS 2........................................ Supported MCS 3........................................ Supported

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

MCS 4........................................ Supported MCS 5........................................ Supported MCS 6........................................ Supported MCS 7........................................ Supported MCS 8........................................ Supported MCS 9........................................ Supported MCS 10....................................... Supported MCS 11....................................... Supported MCS 12....................................... Supported MCS 13....................................... Supported MCS 14....................................... Supported MCS 15....................................... Supported MCS 16....................................... Supported MCS 17....................................... Supported MCS 18....................................... Supported MCS 19....................................... Supported MCS 20....................................... Supported MCS 21....................................... Supported MCS 22....................................... Supported MCS 23....................................... Supported MCS 24....................................... Supported MCS 25....................................... Supported MCS 26....................................... Supported MCS 27....................................... Supported MCS 28....................................... Supported

NIST SP 1800-8C: Securing Wireless Infusion Pumps

181

MCS 29....................................... Supported MCS 30....................................... Supported MCS 31....................................... Supported 802.11ac MCS Settings: Nss=1: MCS 0-9 .............................. Supported Nss=2: MCS 0-9 .............................. Supported Nss=3: MCS 0-9 .............................. Supported

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

Nss=4: MCS 0-7 .............................. Supported 802.11n Status: A-MPDU Tx: Priority 0............................... Enabled Priority 1............................... Enabled Priority 2............................... Enabled Priority 3............................... Enabled Priority 4............................... Enabled Priority 5............................... Enabled Priority 6............................... Disabled Priority 7............................... Disabled Aggregation scheduler.................... Enabled Frame Burst.............................. Automatic Realtime Timeout..................... 10 Non Realtime Timeout................. 200 A-MSDU Tx: Priority 0............................... Enabled Priority 1............................... Enabled Priority 2............................... Enabled Priority 3............................... Enabled Priority 4............................... Enabled Priority 5............................... Enabled Priority 6............................... Disabled Priority 7............................... Disabled A-MSDU Max Subframes ........................ 3

NIST SP 1800-8C: Securing Wireless Infusion Pumps

182

A-MSDU MAX Length ........................... 8k Rifs Rx ..................................... Enabled Guard Interval .............................. Any Beacon Interval.................................. 100 CF Pollable mandatory............................ Disabled CF Poll Request mandatory........................ Disabled CFP Period....................................... 4

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

CFP Maximum Duration............................. 60 Default Channel.................................. 36 Default Tx Power Level........................... 0 DTPC

Status..................................... Enabled

Fragmentation Threshold.......................... 2346 RSSI Low Check................................... Disabled RSSI Threshold................................... -80 TI Threshold..................................... -50 Legacy Tx Beamforming setting.................... Disabled Traffic Stream Metrics Status.................... Disabled Expedited BW Request Status...................... Disabled World Mode....................................... Enabled dfs-peakdetect................................... Enabled EDCA profile type................................ default-wmm Voice MAC optimization status.................... Disabled Call Admission Control (CAC) configuration Voice AC: Voice AC - Admission control (ACM)............ Disabled Voice Stream-Size............................. 84000 Voice Max-Streams............................. 2 Voice max RF bandwidth........................ 75 Voice reserved roaming bandwidth.............. 6 Voice CAC Method ............................. Load-Based Voice tspec inactivity timeout................ Disabled CAC SIP-Voice configuration

NIST SP 1800-8C: Securing Wireless Infusion Pumps

183

SIP based CAC ................................ Disabled SIP Codec Type ............................... CODEC_TYPE_G711 SIP call bandwidth ........................... 64 SIP call bandwith sample-size ................ 20 Video AC: Video AC - Admission control (ACM)............ Disabled Video max RF bandwidth........................ Infinite

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

Video reserved roaming bandwidth.............. 0 Video load-based CAC mode..................... Disabled Video CAC Method ............................. Static CAC SIP-Video Configuration SIP based CAC ................................ Disabled Best-effort AC - Admission control (ACM)...... Disabled Background AC - Admission control (ACM)....... Disabled Maximum Number of Clients per AP Radio........... 200

802.11a Advanced Configuration Member RRM Information AP Name TxPower

MAC Address

Slot Admin

Oper

Channel

-------------------------------- ----------------- ---- -------- ----------- ----------------- ------------AP78da.6ee0.08ec *1/6 (22 dBm)

5c:a4:8a:be:ca:90

1

ENABLED

UP

149*

AP24e9.b34b.f1ed *1/6 (22 dBm)

1c:1d:86:31:e5:50

1

ENABLED

UP

48*

802.11a Airewave Director Configuration RF Event and Performance Logging Channel Update Logging......................... Off Coverage Profile Logging....................... Off Foreign Profile Logging........................ Off Load Profile Logging........................... Off Noise Profile Logging.......................... Off

NIST SP 1800-8C: Securing Wireless Infusion Pumps

184

Performance Profile Logging.................... Off TxPower Update Logging......................... Off Default 802.11a AP performance profiles 802.11a Global Interference threshold.......... 10 % 802.11a Global noise threshold................. -70 dBm 802.11a Global RF utilization threshold........ 80 % 802.11a Global throughput threshold............ 1000000 bps

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

802.11a Global clients threshold............... 12 clients Default 802.11a AP monitoring 802.11a Monitor Mode........................... enable 802.11a Monitor Mode for Mesh AP Backhaul...... disable 802.11a Monitor Channels....................... Country channels 802.11a RRM Neighbor Discover Type............. Transparent 802.11a RRM Neighbor RSSI Normalization........ Enabled 802.11a AP Coverage Interval................... 90 seconds 802.11a AP Load Interval....................... 60 seconds 802.11a AP Monitor Measurement Interval........ 180 seconds 802.11a AP Neighbor Timeout Factor............. 5 802.11a AP Report Measurement Interval......... 180 seconds Leader Automatic Transmit Power Assignment Transmit Power Assignment Mode................. AUTO Transmit Power Update Interval................. 600 seconds Transmit Power Threshold....................... -70 dBm Transmit Power Neighbor Count.................. 3 APs Min Transmit Power............................. -10 dBm Max Transmit Power............................. 30 dBm Update Contribution Noise........................................ Enable Interference................................. Enable Load......................................... Disable Device Aware................................. Disable Transmit Power Assignment Leader............... wlc (192.168.250.2) (::)

NIST SP 1800-8C: Securing Wireless Infusion Pumps

185

Last Run....................................... 21 seconds ago Last Run Time.................................. 0 seconds TPC Mode....................................... Version 1 TPCv2 Target RSSI.............................. -67 dBm TPCv2 VoWLAN Guide RSSI........................ -67.0 dBm TPCv2 SOP...................................... -85.0 dBm

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

TPCv2 Default Client Ant Gain..................

0.0 dBi

TPCv2 Path Loss Decay Factor...................

3.6

TPCv2 Search Intensity......................... 10 Iterations

AP Name

Channel

TxPower

Allowed Power Levels

-------------------------------- ---------- ------------- -----------------------AP78da.6ee0.08ec

149*

*1/6 (22 dBm) [22/19/16/13/10/7/7/7]

AP24e9.b34b.f1ed

48*

*1/6 (22 dBm) [22/19/16/13/10/7/7/7]

Coverage Hole Detection 802.11a Coverage Hole Detection Mode........... Enabled 802.11a Coverage Voice Packet Count............ 100 packets 802.11a Coverage Voice Packet Percentage....... 50% 802.11a Coverage Voice RSSI Threshold.......... -80 dBm 802.11a Coverage Data Packet Count............. 50 packets 802.11a Coverage Data Packet Percentage........ 50% 802.11a Coverage Data RSSI Threshold........... -80 dBm 802.11a Global coverage exception level........ 25 % 802.11a Global client minimum exception lev.... 3 clients OptimizedRoaming 802.11a OptimizedRoaming Mode.................. Disabled 802.11a OptimizedRoaming Reporting Interval.... 90 seconds 802.11a OptimizedRoaming Rate Threshold........ disabled 802.11a OptimizedRoaming Hysteresis............ 6 dB OptimizedRoaming Stats 802.11a OptimizedRoaming Disassociations....... 0 802.11a OptimizedRoaming Rejections............ 0

NIST SP 1800-8C: Securing Wireless Infusion Pumps

186

Leader Automatic Channel Assignment Channel Assignment Mode........................ AUTO Channel Update Interval........................ 600 seconds Anchor time (Hour of the day).................. 0 Update Contribution Noise........................................ Enable Interference................................. Enable

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

Load......................................... Disable Device Aware................................. Disable CleanAir Event-driven RRM option............... Disabled Channel Assignment Leader...................... wlc (192.168.250.2) (::) Last Run....................................... 21 seconds ago Last Run Time.................................. 0 seconds DCA Sensitivity Level.......................... MEDIUM (15 dB) DCA 802.11n/ac Channel Width................... 20 MHz DCA Minimum Energy Limit....................... -95 dBm Channel Energy Levels Minimum...................................... -127 dBm Average...................................... -127 dBm Maximum...................................... -127 dBm Channel Dwell Times Minimum...................................... 0 days, 00 h 00 m 19 s Average...................................... 0 days, 00 h 00 m 19 s Maximum...................................... 0 days, 00 h 00 m 19 s 802.11a 5 GHz Auto-RF Channel List Allowed Channel List......................... 36,40,44,48,52,56,60,64,100, 104,108,112,116,120,124,128, 132,136,140,144,149,153,157, 161 Unused Channel List.......................... 165 802.11a 4.9 GHz Auto-RF Channel List Allowed Channel List.........................

NIST SP 1800-8C: Securing Wireless Infusion Pumps

187

Unused Channel List.......................... 1,2,3,4,5,6,7,8,9,10,11,12, 13,14,15,16,17,18,19,20,21, 22,23,24,25,26 DCA Outdoor AP option.......................... Disabled 802.11a Radio RF Grouping RF Group Name.................................. WLAN RF Protocol Version(MIN)....................... 101(30)

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

RF Packet Header Version....................... 2 Group Role(Mode)............................... LEADER(AUTO) Group State.................................... Idle Group Update Interval.......................... 600 seconds Group Leader................................... wlc (192.168.250.2) (::) Group Member ................................. wlc (192.168.250.2) Maximum/Current number of Group Member......... 20/1 Maximum/Current number of AP................... 500/2 Last Run....................................... 21 seconds ago 802.11a CleanAir Configuration

Clean Air Solution............................... Disabled Air Quality Settings: Air Quality Reporting........................ Enabled Air Quality Reporting Period (min)........... 15 Air Quality Alarms........................... Enabled Air Quality Alarm Threshold................ 35 Unclassified Interference.................. Disabled Unclassified Severity Threshold............ 20 Interference Device Settings: Interference Device Reporting................ Enabled Interference Device Types: TDD Transmitter.......................... Enabled Jammer................................... Enabled

NIST SP 1800-8C: Securing Wireless Infusion Pumps

188

Continuous Transmitter................... Enabled DECT-like Phone.......................... Enabled Video Camera............................. Enabled WiFi Inverted............................ Enabled WiFi Invalid Channel..................... Enabled SuperAG.................................. Enabled Canopy................................... Enabled

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

WiMax Mobile............................. Enabled WiMax Fixed.............................. Enabled Interference Device Alarms................... Enabled Interference Device Types Triggering Alarms: TDD Transmitter.......................... Disabled Jammer................................... Enabled Continuous Transmitter................... Disabled DECT-like Phone.......................... Disabled Video Camera............................. Disabled WiFi Inverted............................ Enabled WiFi Invalid Channel..................... Enabled SuperAG.................................. Disabled Canopy................................... Disabled WiMax Mobile............................. Disabled WiMax Fixed.............................. Disabled Additional Clean Air Settings: CleanAir ED-RRM State........................ Disabled CleanAir ED-RRM Sensitivity.................. Medium CleanAir ED-RRM Custom Threshold............. 50 CleanAir Rogue Contribution.................. Disabled CleanAir Rogue Duty-Cycle Threshold.......... 80 CleanAir Persistent Devices state............ Disabled CleanAir Persistent Device Propagation....... Disabled

802.11a CleanAir AirQuality Summary

NIST SP 1800-8C: Securing Wireless Infusion Pumps

189

AQ = Air Quality DFS = Dynamic Frequency Selection

AP Name

Channel Avg AQ Min AQ Interferers DFS

------------------ ------- ------ ------ ----------- ---

802.11b Configuration

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

802.11b Network.................................. Enabled 11gSupport....................................... Enabled 11nSupport....................................... Enabled 802.11b/g Operational Rates 802.11b/g 1M Rate............................ Mandatory 802.11b/g 2M Rate............................ Mandatory 802.11b/g 5.5M Rate.......................... Mandatory 802.11b/g 11M Rate........................... Mandatory 802.11g 6M Rate.............................. Supported 802.11g 9M Rate.............................. Supported 802.11g 12M Rate............................. Supported 802.11g 18M Rate............................. Supported 802.11g 24M Rate............................. Supported 802.11g 36M Rate............................. Supported 802.11g 48M Rate............................. Supported 802.11g 54M Rate............................. Supported 802.11n MCS Settings: MCS 0........................................ Supported MCS 1........................................ Supported MCS 2........................................ Supported MCS 3........................................ Supported MCS 4........................................ Supported MCS 5........................................ Supported MCS 6........................................ Supported MCS 7........................................ Supported

NIST SP 1800-8C: Securing Wireless Infusion Pumps

190

MCS 8........................................ Supported MCS 9........................................ Supported MCS 10....................................... Supported MCS 11....................................... Supported MCS 12....................................... Supported MCS 13....................................... Supported MCS 14....................................... Supported

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

MCS 15....................................... Supported MCS 16....................................... Supported MCS 17....................................... Supported MCS 18....................................... Supported MCS 19....................................... Supported MCS 20....................................... Supported MCS 21....................................... Supported MCS 22....................................... Supported MCS 23....................................... Supported MCS 24....................................... Supported MCS 25....................................... Supported MCS 26....................................... Supported MCS 27....................................... Supported MCS 28....................................... Supported MCS 29....................................... Supported MCS 30....................................... Supported MCS 31....................................... Supported 802.11n Status: A-MPDU Tx: Priority 0............................... Enabled Priority 1............................... Enabled Priority 2............................... Enabled Priority 3............................... Enabled Priority 4............................... Enabled Priority 5............................... Enabled

NIST SP 1800-8C: Securing Wireless Infusion Pumps

191

Priority 6............................... Disabled Priority 7............................... Disabled Aggregation scheduler.................... Enabled Realtime Timeout..................... 10 Non Realtime Timeout................. 200 A-MSDU Tx: Priority 0............................... Enabled

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

Priority 1............................... Enabled Priority 2............................... Enabled Priority 3............................... Enabled Priority 4............................... Enabled Priority 5............................... Enabled Priority 6............................... Disabled Priority 7............................... Disabled A-MSDU Max Subframes ........................ 3 A-MSDU MAX Length ........................... 8k Rifs Rx ..................................... Enabled Guard Interval .............................. Any Beacon Interval.................................. 100 CF Pollable mode................................. Disabled CF Poll Request mandatory........................ Disabled CFP Period....................................... 4 CFP Maximum Duration............................. 60 Default Channel.................................. 1 Default Tx Power Level........................... 0 DTPC

Status..................................... Enabled

RSSI Low Check................................... Disabled RSSI Threshold................................... -80 Call Admission Limit

........................... 105

G711 CU Quantum ................................. 15 ED Threshold..................................... -50 Fragmentation Threshold.......................... 2346

NIST SP 1800-8C: Securing Wireless Infusion Pumps

192

PBCC mandatory................................... Disabled RTS Threshold.................................... 2347 Short Preamble mandatory......................... Enabled Short Retry Limit................................ 7 Legacy Tx Beamforming setting.................... Disabled Traffic Stream Metrics Status.................... Disabled Expedited BW Request Status...................... Disabled

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

World Mode....................................... Enabled Faster Carrier Tracking Loop..................... Disabled EDCA profile type................................ default-wmm Voice MAC optimization status.................... Disabled Call Admission Control (CAC) configuration Voice AC - Admission control (ACM)............ Disabled Voice Stream-Size............................. 84000 Voice Max-Streams............................. 2 Voice max RF bandwidth........................ 75 Voice reserved roaming bandwidth.............. 6 Voice CAC Method.............................. Load-Based Voice tspec inactivity timeout................ Disabled CAC SIP-Voice configuration SIP based CAC ................................ Disabled SIP Codec Type ............................... CODEC_TYPE_G711 SIP call bandwidth: .......................... 64 SIP call bandwidth sample-size ............... 20 Video AC - Admission control (ACM)............ Disabled Video max RF bandwidth........................ Infinite Video reserved roaming bandwidth.............. 0 Video load-based CAC mode..................... Disabled Video CAC Method ............................. Static CAC SIP-Video configuration SIP based CAC ................................ Disabled Best-effort AC - Admission control (ACM)...... Disabled

NIST SP 1800-8C: Securing Wireless Infusion Pumps

193

Background AC - Admission control (ACM)....... Disabled Maximum Number of Clients per AP................. 200

802.11b Advanced Configuration Member RRM Information

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

AP Name TxPower

MAC Address

Admin

Oper

Channel

-------------------------------- ----------------- -------- ----------- ---------- -----------AP78da.6ee0.08ec *1/6 (22 dBm)

5c:a4:8a:be:ca:90 ENABLED

UP

11*

AP24e9.b34b.f1ed *1/6 (22 dBm)

1c:1d:86:31:e5:50 ENABLED

UP

11*

802.11b Airewave Director Configuration RF Event and Performance Logging Channel Update Logging......................... Off Coverage Profile Logging....................... Off Foreign Profile Logging........................ Off Load Profile Logging........................... Off Noise Profile Logging.......................... Off Performance Profile Logging.................... Off Transmit Power Update Logging.................. Off Default 802.11b AP performance profiles 802.11b Global Interference threshold.......... 10 % 802.11b Global noise threshold................. -70 dBm 802.11b Global RF utilization threshold........ 80 % 802.11b Global throughput threshold............ 1000000 bps 802.11b Global clients threshold............... 12 clients

NIST SP 1800-8C: Securing Wireless Infusion Pumps

194

Default 802.11b AP monitoring 802.11b Monitor Mode........................... enable 802.11b Monitor Channels....................... Country channels 802.11b RRM Neighbor Discovery Type............ Transparent 802.11b RRM Neighbor RSSI Normalization........ Enabled 802.11b AP Coverage Interval................... 90 seconds 802.11b AP Load Interval....................... 60 seconds

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

802.11b AP Monitor Measurement Interval........ 180 seconds 802.11b AP Neighbor Timeout Factor............. 5 802.11b AP Report Measurement Interval......... 180 seconds Leader Automatic Transmit Power Assignment Transmit Power Assignment Mode................. AUTO Transmit Power Update Interval................. 600 seconds Transmit Power Threshold....................... -70 dBm Transmit Power Neighbor Count.................. 3 APs Min Transmit Power............................. -10 dBm Max Transmit Power............................. 30 dBm Update Contribution Noise........................................ Enable Interference................................. Enable Load......................................... Disable Device Aware................................. Disable Transmit Power Assignment Leader............... wlc (192.168.250.2) (::) Last Run....................................... 225 seconds ago Last Run Time.................................. 0 seconds TPC Mode....................................... Version 1 TPCv2 Target RSSI.............................. -67 dBm TPCv2 VoWLAN Guide RSSI........................ -67.0 dBm TPCv2 SOP...................................... -85.0 dBm TPCv2 Default Client Ant Gain..................

0.0 dBi

TPCv2 Path Loss Decay Factor...................

3.6

TPCv2 Search Intensity......................... 10 Iterations

NIST SP 1800-8C: Securing Wireless Infusion Pumps

195

AP Name

Channel

TxPower

Allowed Power Levels

-------------------------------- ---------- ------------- -----------------------AP78da.6ee0.08ec

*11

*1/6 (22 dBm) [22/19/16/13/10/7/7/7]

AP24e9.b34b.f1ed

*11

*1/6 (22 dBm) [22/19/16/13/10/7/7/7]

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

Coverage Hole Detection 802.11b Coverage Hole Detection Mode........... Enabled 802.11b Coverage Voice Packet Count............ 100 packets 802.11b Coverage Voice Packet Percentage....... 50% 802.11b Coverage Voice RSSI Threshold.......... -80 dBm 802.11b Coverage Data Packet Count............. 50 packets 802.11b Coverage Data Packet Percentage........ 50% 802.11b Coverage Data RSSI Threshold........... -80 dBm 802.11b Global coverage exception level........ 25 % 802.11b Global client minimum exception lev.... 3 clients OptimizedRoaming 802.11b OptimizedRoaming Mode.................. Disabled 802.11b OptimizedRoaming Reporting Interval.... 90 seconds 802.11b OptimizedRoaming Rate Threshold........ disabled 802.11b OptimizedRoaming Hysteresis............ 6 dB OptimizedRoaming Stats 802.11b OptimizedRoaming Disassociations....... 0 802.11b OptimizedRoaming Rejections............ 0 Leader Automatic Channel Assignment Channel Assignment Mode........................ AUTO Channel Update Interval........................ 600 seconds Anchor time (Hour of the day).................. 0 Update Contribution Noise........................................ Enable Interference................................. Enable

NIST SP 1800-8C: Securing Wireless Infusion Pumps

196

Load......................................... Disable Device Aware................................. Disable CleanAir Event-driven RRM option............... Disabled Channel Assignment Leader...................... wlc (192.168.250.2) (::) Last Run....................................... 225 seconds ago Last Run Time.................................. 0 seconds

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

DCA Sensitivity Level: ...................... MEDIUM (10 dB) DCA Minimum Energy Limit....................... -95 dBm Channel Energy Levels Minimum...................................... -127 dBm Average...................................... -127 dBm Maximum...................................... -127 dBm Channel Dwell Times Minimum...................................... 0 days, 00 h 03 m 43 s Average...................................... 0 days, 00 h 03 m 43 s Maximum...................................... 0 days, 00 h 03 m 43 s 802.11b Auto-RF Allowed Channel List........... 1,6,11 Auto-RF Unused Channel List.................... 2,3,4,5,7,8,9,10 802.11b Radio RF Grouping RF Group Name.................................. WLAN RF Protocol Version(MIN)....................... 101(30) RF Packet Header Version....................... 2 Group Role(Mode)............................... LEADER(AUTO) Group State.................................... Idle Group Update Interval.......................... 600 seconds Group Leader................................... wlc (192.168.250.2) (::) Group Member ................................. wlc (192.168.250.2) Maximum/Current number of Group Member......... 20/1 Maximum/Current number of AP................... 500/2 Last Run....................................... 225 seconds ago

NIST SP 1800-8C: Securing Wireless Infusion Pumps

197

802.11b CleanAir Configuration

Clean Air Solution............................... Disabled Air Quality Settings: Air Quality Reporting........................ Enabled Air Quality Reporting Period (min)........... 15 Air Quality Alarms........................... Enabled

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

Air Quality Alarm Threshold................ 35 Unclassified Interference.................. Disabled Unclassified Severity Threshold............ 20 Interference Device Settings: Interference Device Reporting................ Enabled Interference Device Types: Bluetooth Link........................... Enabled Microwave Oven........................... Enabled 802.11 FH................................ Enabled Bluetooth Discovery...................... Enabled TDD Transmitter.......................... Enabled Jammer................................... Enabled Continuous Transmitter................... Enabled DECT-like Phone.......................... Enabled Video Camera............................. Enabled 802.15.4................................. Enabled WiFi Inverted............................ Enabled WiFi Invalid Channel..................... Enabled SuperAG.................................. Enabled Canopy................................... Enabled Microsoft Device......................... Enabled WiMax Mobile............................. Enabled WiMax Fixed.............................. Enabled BLE Beacon............................... Enabled Interference Device Alarms................... Enabled

NIST SP 1800-8C: Securing Wireless Infusion Pumps

198

Interference Device Types Triggering Alarms: Bluetooth Link........................... Disabled Microwave Oven........................... Disabled 802.11 FH................................ Disabled Bluetooth Discovery...................... Disabled TDD Transmitter.......................... Disabled Jammer................................... Enabled

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

Continuous Transmitter................... Disabled DECT-like Phone.......................... Disabled Video Camera............................. Disabled 802.15.4................................. Disabled WiFi Inverted............................ Enabled WiFi Invalid Channel..................... Enabled SuperAG.................................. Disabled Canopy................................... Disabled Microsoft Device......................... Disabled WiMax Mobile............................. Disabled WiMax Fixed.............................. Disabled BLE Beacon............................... Disabled Additional Clean Air Settings: CleanAir ED-RRM State........................ Disabled CleanAir ED-RRM Sensitivity.................. Medium CleanAir ED-RRM Custom Threshold............. 50 CleanAir Rogue Contribution.................. Disabled CleanAir Rogue Duty-Cycle Threshold.......... 80 CleanAir Persistent Devices state............ Disabled CleanAir Persistent Device Propagation....... Disabled

802.11a CleanAir AirQuality Summary AQ = Air Quality DFS = Dynamic Frequency Selection

NIST SP 1800-8C: Securing Wireless Infusion Pumps

199

AP Name

Channel Avg AQ Min AQ Interferers DFS

------------------ ------- ------ ------ ----------- ---

RF Density Optimization Configurations

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

FRA State........................................ Disabled FRA Sensitivity.................................. low (100) FAR Interval..................................... 1 Hour(s) Last Run....................................... 2703 seconds ago Last Run Time.................................. 0 seconds

AP Name Suggested Mode

MAC Address

Slot Current Band

COF %

-------------------------------- ----------------- ---- -------------- ------------------- -------------------------

COF : Coverage Overlap Factor

RF Client Steering Configurations Client Steering Configuration Information

Macro to micro transition threshold............ -55 dBm micro to Macro transition threshold............ -65 dBm micro-Macro transition minimum client count.... 3 micro-Macro transition client balancing win.... 3 Probe suppression mode......................... disabled

NIST SP 1800-8C: Securing Wireless Infusion Pumps

200

Probe suppression validity window.............. 100 s Probe suppression aggregate window............. 200 ms Probe suppression transition aggressiveness.... 3 Probe suppression hysteresis................... -6 dBm

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

Mobility Configuration Mobility Protocol Port........................... 16666 Default Mobility Domain.......................... WLAN Multicast Mode .................................. Disabled Mobility Domain ID for 802.11r................... 0xf6a2 Mobility Keepalive Interval...................... 10 Mobility Keepalive Count......................... 3 Mobility Group Members Configured................ 1 Mobility Control Message DSCP Value.............. 0

Controllers configured in the Mobility Group MAC Address Multicast IP

IP Address

00:50:56:ac:6d:08 0.0.0.0

192.168.250.2

Group Name Status WLAN Up

Mobility Hash Configuration

Default Mobility Domain.......................... WLAN

IP Address

Hash Key

---------------------------------------------------------

NIST SP 1800-8C: Securing Wireless Infusion Pumps

201

192.168.250.2

7a9b864fa2922672949cf9a66fd012a0ce8cc7b0

Self Signed Certificate details

SSC Hash validation.............................. Enabled.

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

SSC Device Certificate details:

Subject Name : C=US, ST=California, L=San Jose, O=Cisco Virtual Wireless LAN Controller, CN=DEVICE-vWLC-AIR-CTVM-K9-005056AC6338, emailAddress=support@vwlc.com

Validity : Start : Jul 26 20:52:54 2016 GMT End

: Jun

4 20:52:54 2026 GMT

Hash key : 7a9b864fa2922672949cf9a66fd012a0ce8cc7b0

Mobility Foreign Map Configuration WLAN ID

Foreign Mac Address

Interface

-------

-------------------

---------

Advanced Configuration

NIST SP 1800-8C: Securing Wireless Infusion Pumps

202

Probe request filtering..........................

Enabled

Probes fwd to controller per client per radio....

2

Probe request rate-limiting interval.............

500 msec

Aggregate Probe request interval.................

500 msec

Increased backoff parameters for probe respon....

Disabled

EAP-Identity-Request Timeout (seconds)........... 30

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

EAP-Identity-Request Max Retries................. 2 EAP Key-Index for Dynamic WEP.................... 0 EAP Max-Login Ignore Identity Response........... enable EAP-Request Timeout (seconds).................... 30 EAP-Request Max Retries.......................... 2 EAPOL-Key Timeout (milliseconds)................. 1000 EAPOL-Key Max Retries............................ 2 EAP-Broadcast Key Interval....................... 3600

dot11-padding.................................... Disabled

padding-size..................................... 0 Advanced Hotspot Commands

ANQP 4-way state................................. Disabled GARP Broadcast state: ........................... Enabled GAS request rate limit .......................... Disabled ANQP comeback delay in TUs(TU=1024usec).......... 1 TUs (=1mSec)

Location Configuration RFID Tag data Collection......................... Enabled RFID

timeout.................................... 1200 seconds

NIST SP 1800-8C: Securing Wireless Infusion Pumps

203

RFID mobility....................................

Interface Configuration Interface Name................................... ip_dev MAC Address...................................... 00:50:56:ac:6d:08

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

IP Address....................................... 192.168.150.2 IP Netmask....................................... 255.255.255.0 IP Gateway....................................... 192.168.150.1 External NAT IP State............................ Disabled External NAT IP Address.......................... 0.0.0.0 VLAN............................................. 1500 Quarantine-vlan.................................. 0 NAS-Identifier................................... none Physical Port.................................... 1 DHCP Proxy Mode.................................. Global Primary DHCP Server.............................. Unconfigured Secondary DHCP Server............................ Unconfigured DHCP Option 82................................... Disabled DHCP Option 82 bridge mode insertion............. Disabled IPv4 ACL......................................... Unconfigured mDNS Profile Name................................ Unconfigured AP Manager....................................... No Guest Interface.................................. N/A 3G VLAN.......................................... Disabled L2 Multicast..................................... Enabled

Interface Name................................... management MAC Address...................................... 00:50:56:ac:6d:08 IP Address....................................... 192.168.250.2 IP Netmask....................................... 255.255.255.0

NIST SP 1800-8C: Securing Wireless Infusion Pumps

204

IP Gateway....................................... 192.168.250.1 External NAT IP State............................ Disabled External NAT IP Address.......................... 0.0.0.0 Link Local IPv6 Address.......................... fe80::250:56ff:feac:6d08/64 STATE ........................................... REACHABLE Primary IPv6 Address............................. ::/128 STATE ........................................... NONE

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

Primary IPv6 Gateway............................. :: Primary IPv6 Gateway Mac Address................. 00:00:00:00:00:00 STATE ........................................... INCOMPLETE VLAN............................................. 1520 Quarantine-vlan.................................. 0 Physical Port.................................... 1 DHCP Proxy Mode.................................. Global Primary DHCP Server.............................. 192.168.250.1 Secondary DHCP Server............................ Unconfigured DHCP Option 82................................... Disabled DHCP Option 82 bridge mode insertion............. Disabled IPv4 ACL......................................... Unconfigured IPv6 ACL......................................... Unconfigured mDNS Profile Name................................ Unconfigured AP Manager....................................... Yes Guest Interface.................................. N/A L2 Multicast..................................... Enabled

Interface Name................................... service-port MAC Address...................................... 00:50:56:ac:63:38 IP Address....................................... 192.168.29.146 IP Netmask....................................... 255.255.255.0 Link Local IPv6 Address.......................... fe80::250:56ff:feac:6338/64 STATE ........................................... NONE IPv6 Address..................................... ::/128

NIST SP 1800-8C: Securing Wireless Infusion Pumps

205

STATE ........................................... NONE SLAAC............................................ Disabled DHCP Protocol.................................... Disabled AP Manager....................................... No Guest Interface.................................. N/A Speed ........................................... 1Gbps Duplex .......................................... Full

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

Auto Negotiation ................................ Enabled Link Status...................................... Up Port specific Information: inet addr:192.168.29.146

Bcast:192.168.29.255

Mask:255.255.255.0 inet6 addr:

fe80::250:56ff:feac:6338/64 Scope:Link UP BROADCAST RUNNING MULTICAST

MTU:1430

Metric:1

RX packets:258830 errors:0 dropped:298 overruns:0 frame:0 TX packets:95115 errors:0 dropped:0 overruns:0 carrier:0 collisions:0 txqueuelen:1000 RX bytes:25069479 (23.9 MiB)

TX bytes:55852901 (53.2 MiB)

Interface Name................................... virtual MAC Address...................................... 00:50:56:ac:6d:08 IP Address....................................... 1.1.1.1 Virtual DNS Host Name............................ Disabled AP Manager....................................... No Guest Interface.................................. N/A

NIST SP 1800-8C: Securing Wireless Infusion Pumps

206

Interface Group Configuration

WLAN Configuration

WLAN Identifier.................................. 1

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

Profile Name..................................... IP_Dev No Encryption Network Name (SSID).............................. IP_Dev Status........................................... Disabled MAC Filtering.................................... Disabled Broadcast SSID................................... Enabled AAA Policy Override.............................. Disabled Network Admission Control Client Profiling Status Radius Profiling ............................ Disabled DHCP ....................................... Disabled HTTP ....................................... Disabled Local Profiling ............................. Disabled DHCP ....................................... Disabled HTTP ....................................... Disabled Radius-NAC State............................... Disabled SNMP-NAC State................................. Disabled Quarantine VLAN................................ 0 Maximum number of Associated Clients............. 0 Maximum number of Clients per AP Radio........... 200 ATF Policy....................................... 0 Number of Active Clients......................... 0 Exclusionlist Timeout............................ 60 seconds Session Timeout.................................. 86400 seconds User Idle Timeout................................ Disabled Sleep Client..................................... disable

NIST SP 1800-8C: Securing Wireless Infusion Pumps

207

Sleep Client Timeout............................. 720 minutes User Idle Threshold.............................. 0 Bytes NAS-identifier................................... none CHD per WLAN..................................... Enabled Webauth DHCP exclusion........................... Disabled Interface........................................ ip_dev Multicast Interface.............................. Not Configured

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

WLAN IPv4 ACL.................................... unconfigured WLAN IPv6 ACL.................................... unconfigured WLAN Layer2 ACL.................................. unconfigured mDNS Status...................................... Disabled mDNS Profile Name................................ unconfigured DHCP Server...................................... Default DHCP Address Assignment Required................. Disabled Static IP client tunneling....................... Disabled Tunnel Profile................................... Unconfigured Quality of Service............................... Silver Per-SSID Rate Limits............................. Upstream

Downstream

Average Data Rate................................

0

0

Average Realtime Data Rate.......................

0

0

Burst Data Rate..................................

0

0

Burst Realtime Data Rate.........................

0

0

Per-Client Rate Limits........................... Upstream

Downstream

Average Data Rate................................

0

0

Average Realtime Data Rate.......................

0

0

Burst Data Rate..................................

0

0

Burst Realtime Data Rate.........................

0

0

Scan Defer Priority.............................. 4,5,6 Scan Defer Time.................................. 100 milliseconds WMM.............................................. Allowed WMM UAPSD Compliant Client Support............... Disabled Media Stream Multicast-direct.................... Disabled

NIST SP 1800-8C: Securing Wireless Infusion Pumps

208

CCX - AironetIe Support.......................... Enabled CCX - Gratuitous ProbeResponse (GPR)............. Disabled CCX - Diagnostics Channel Capability............. Disabled Dot11-Phone Mode (7920).......................... Disabled Wired Protocol................................... 802.1P (Tag=0) Passive Client Feature........................... Disabled Peer-to-Peer Blocking Action..................... Disabled

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

Radio Policy..................................... All DTIM period for 802.11a radio.................... 1 DTIM period for 802.11b radio.................... 1 Radius Servers Authentication................................ Global Servers Accounting.................................... Global Servers Interim Update............................. Enabled Interim Update Interval.................... 0 Framed IPv6 Acct AVP ...................... Prefix Dynamic Interface............................. Disabled Dynamic Interface Priority.................... wlan Local EAP Authentication......................... Disabled Radius NAI-Realm................................. Disabled Mu-Mimo.......................................... Enabled Security

802.11 Authentication:........................ Open System FT Support.................................... Disabled Static WEP Keys............................... Disabled 802.1X........................................ Disabled Wi-Fi Protected Access (WPA/WPA2)............. Disabled Wi-Fi Direct policy configured................ Disabled EAP-Passthrough............................... Disabled CKIP ......................................... Disabled Web Based Authentication...................... Disabled

NIST SP 1800-8C: Securing Wireless Infusion Pumps

209

Web Authentication Timeout.................... 300 Web-Passthrough............................... Disabled Mac-auth-server............................... 0.0.0.0 Web-portal-server............................. 0.0.0.0 Conditional Web Redirect...................... Disabled Splash-Page Web Redirect...................... Disabled Auto Anchor................................... Disabled

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

FlexConnect Local Switching................... Enabled FlexConnect Central Association............... Disabled flexconnect Central Dhcp Flag................. Disabled flexconnect nat-pat Flag...................... Disabled flexconnect Dns Override Flag................. Disabled flexconnect PPPoE pass-through................ Disabled flexconnect local-switching IP-source-guar.... Disabled FlexConnect Vlan based Central Switching ..... Disabled FlexConnect Local Authentication.............. Disabled FlexConnect Learn IP Address.................. Enabled Client MFP.................................... Optional but inactive (WPA2 not configured) PMF........................................... Disabled PMF Association Comeback Time................. 1 PMF SA Query RetryTimeout..................... 200 Tkip MIC Countermeasure Hold-down Timer....... 60 Eap-params.................................... Not Applicable Flex Avc Profile Name............................ None Flow Monitor Name................................ None Split Tunnel Configuration Split Tunnel................................. Disabled Call Snooping.................................... Disabled Roamed Call Re-Anchor Policy..................... Disabled SIP CAC Fail Send-486-Busy Policy................ Enabled SIP CAC Fail Send Dis-Association Policy......... Disabled

NIST SP 1800-8C: Securing Wireless Infusion Pumps

210

KTS based CAC Policy............................. Disabled Assisted Roaming Prediction Optimization......... Disabled 802.11k Neighbor List............................ Disabled 802.11k Neighbor List Dual Band.................. Disabled 802.11v Directed Multicast Service............... Disabled 802.11v BSS Max Idle Service..................... Enabled 802.11v BSS Transition Service................... Disabled

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

802.11v BSS Transition Disassoc Imminent......... Disabled 802.11v BSS Transition Disassoc Timer............ 200 802.11v BSS Transition OpRoam Disassoc Timer..... 40 DMS DB is empty Band Select...................................... Disabled Load Balancing................................... Disabled Multicast Buffer................................. Disabled Universal Ap Admin............................... Disabled

Mobility Anchor List WLAN ID

IP Address

Status

Priority

-------

---------------

------

--------

802.11u........................................ Disabled

MSAP Services.................................. Disabled

Local Policy ---------------Priority

Policy Name

--------

---------------

WLAN Configuration

WLAN Identifier.................................. 2

NIST SP 1800-8C: Securing Wireless Infusion Pumps

211

Profile Name..................................... IP_Dev All WPA/WPA2 PSK Network Name (SSID).............................. IP_Dev Status........................................... Enabled MAC Filtering.................................... Disabled Broadcast SSID................................... Enabled AAA Policy Override.............................. Disabled Network Admission Control

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

Client Profiling Status Radius Profiling ............................ Disabled DHCP ....................................... Disabled HTTP ....................................... Disabled Local Profiling ............................. Disabled DHCP ....................................... Disabled HTTP ....................................... Disabled Radius-NAC State............................... Disabled SNMP-NAC State................................. Disabled Quarantine VLAN................................ 0 Maximum number of Associated Clients............. 0 Maximum number of Clients per AP Radio........... 200 ATF Policy....................................... 0 Number of Active Clients......................... 2 Exclusionlist Timeout............................ 60 seconds Session Timeout.................................. 1800 seconds User Idle Timeout................................ Disabled Sleep Client..................................... disable Sleep Client Timeout............................. 720 minutes User Idle Threshold.............................. 0 Bytes NAS-identifier................................... none CHD per WLAN..................................... Enabled Webauth DHCP exclusion........................... Disabled Interface........................................ ip_dev Multicast Interface.............................. Not Configured

NIST SP 1800-8C: Securing Wireless Infusion Pumps

212

WLAN IPv4 ACL.................................... unconfigured WLAN IPv6 ACL.................................... unconfigured WLAN Layer2 ACL.................................. unconfigured mDNS Status...................................... Disabled mDNS Profile Name................................ unconfigured DHCP Server...................................... Default DHCP Address Assignment Required................. Disabled

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

Static IP client tunneling....................... Disabled Tunnel Profile................................... Unconfigured Quality of Service............................... Silver Per-SSID Rate Limits............................. Upstream

Downstream

Average Data Rate................................

0

0

Average Realtime Data Rate.......................

0

0

Burst Data Rate..................................

0

0

Burst Realtime Data Rate.........................

0

0

Per-Client Rate Limits........................... Upstream

Downstream

Average Data Rate................................

0

0

Average Realtime Data Rate.......................

0

0

Burst Data Rate..................................

0

0

Burst Realtime Data Rate.........................

0

0

Scan Defer Priority.............................. 4,5,6 Scan Defer Time.................................. 100 milliseconds WMM.............................................. Allowed WMM UAPSD Compliant Client Support............... Disabled Media Stream Multicast-direct.................... Disabled CCX - AironetIe Support.......................... Enabled CCX - Gratuitous ProbeResponse (GPR)............. Disabled CCX - Diagnostics Channel Capability............. Disabled Dot11-Phone Mode (7920).......................... Disabled Wired Protocol................................... 802.1P (Tag=0) Passive Client Feature........................... Disabled Peer-to-Peer Blocking Action..................... Disabled

NIST SP 1800-8C: Securing Wireless Infusion Pumps

213

Radio Policy..................................... All DTIM period for 802.11a radio.................... 1 DTIM period for 802.11b radio.................... 1 Radius Servers Authentication................................ Global Servers Accounting.................................... Global Servers Interim Update............................. Enabled

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

Interim Update Interval.................... 0 Framed IPv6 Acct AVP ...................... Prefix Dynamic Interface............................. Disabled Dynamic Interface Priority.................... wlan Local EAP Authentication......................... Disabled Radius NAI-Realm................................. Disabled Mu-Mimo.......................................... Enabled Security

802.11 Authentication:........................ Open System FT Support.................................... Disabled Static WEP Keys............................... Disabled 802.1X........................................ Disabled Wi-Fi Protected Access (WPA/WPA2)............. Enabled WPA (SSN IE)............................... Enabled TKIP Cipher............................. Enabled AES Cipher.............................. Enabled WPA2 (RSN IE).............................. Enabled TKIP Cipher............................. Disabled AES Cipher.............................. Enabled OSEN IE.................................... Disabled Auth Key Management 802.1x.................................. Disabled PSK..................................... Enabled CCKM.................................... Disabled

NIST SP 1800-8C: Securing Wireless Infusion Pumps

214

FT-1X(802.11r).......................... Disabled FT-PSK(802.11r)......................... Disabled PMF-1X(802.11w)......................... Disabled PMF-PSK(802.11w)........................ Disabled OSEN-1X................................. Disabled FT Reassociation Timeout................... 20 FT Over-The-DS mode........................ Disabled

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

GTK Randomization.......................... Disabled SKC Cache Support.......................... Disabled CCKM TSF Tolerance......................... 1000 Wi-Fi Direct policy configured................ Disabled EAP-Passthrough............................... Disabled CKIP ......................................... Disabled Web Based Authentication...................... Disabled Web Authentication Timeout.................... 300 Web-Passthrough............................... Disabled Mac-auth-server............................... 0.0.0.0 Web-portal-server............................. 0.0.0.0 Conditional Web Redirect...................... Disabled Splash-Page Web Redirect...................... Disabled Auto Anchor................................... Disabled FlexConnect Local Switching................... Disabled FlexConnect Central Association............... Disabled flexconnect Central Dhcp Flag................. Disabled flexconnect nat-pat Flag...................... Disabled flexconnect Dns Override Flag................. Disabled flexconnect PPPoE pass-through................ Disabled flexconnect local-switching IP-source-guar.... Disabled FlexConnect Vlan based Central Switching ..... Disabled FlexConnect Local Authentication.............. Disabled FlexConnect Learn IP Address.................. Enabled Client MFP.................................... Optional

NIST SP 1800-8C: Securing Wireless Infusion Pumps

215

PMF........................................... Disabled PMF Association Comeback Time................. 1 PMF SA Query RetryTimeout..................... 200 Tkip MIC Countermeasure Hold-down Timer....... 60 Eap-params.................................... Disabled Flex Avc Profile Name............................ None Flow Monitor Name................................ None

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

Split Tunnel Configuration Split Tunnel................................. Disabled Call Snooping.................................... Disabled Roamed Call Re-Anchor Policy..................... Disabled SIP CAC Fail Send-486-Busy Policy................ Enabled SIP CAC Fail Send Dis-Association Policy......... Disabled KTS based CAC Policy............................. Disabled Assisted Roaming Prediction Optimization......... Disabled 802.11k Neighbor List............................ Disabled 802.11k Neighbor List Dual Band.................. Disabled 802.11v Directed Multicast Service............... Disabled 802.11v BSS Max Idle Service..................... Enabled 802.11v BSS Transition Service................... Disabled 802.11v BSS Transition Disassoc Imminent......... Disabled 802.11v BSS Transition Disassoc Timer............ 200 802.11v BSS Transition OpRoam Disassoc Timer..... 40 DMS DB is empty Band Select...................................... Disabled Load Balancing................................... Disabled Multicast Buffer................................. Disabled Universal Ap Admin............................... Disabled

Mobility Anchor List WLAN ID

IP Address

Status

Priority

-------

---------------

------

--------

NIST SP 1800-8C: Securing Wireless Infusion Pumps

216

802.11u........................................ Disabled

MSAP Services.................................. Disabled

Local Policy ----------------

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

Priority

Policy Name

--------

---------------

Policy Configuration

L2ACL Configuration

ACL Configuration

CPU ACL Configuration

CPU Acl Name................................ NOT CONFIGURED Wireless Traffic............................ Disabled Wired Traffic............................... Disabled

NIST SP 1800-8C: Securing Wireless Infusion Pumps

217

RADIUS Configuration Vendor Id Backward Compatibility................. Disabled Call Station Id Case............................. lower Accounting Call Station Id Type.................. Mac Address Auth Call Station Id Type........................ AP's Radio MAC Address:SSID

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

Extended Source Ports Support.................... Enabled Aggressive Failover.............................. Enabled Keywrap.......................................... Disabled Fallback Test: Test Mode.................................... Passive Probe User Name.............................. cisco-probe Interval (in seconds)........................ 300 MAC Delimiter for Authentication Messages........ hyphen MAC Delimiter for Accounting Messages............ hyphen RADIUS Authentication Framed-MTU................. 1300 Bytes

Authentication Servers

Idx Type Server Address Port State Tout AuthMode/Phase1/Group/Lifetime/Auth/Encr/Region

MgmtTout

RFC3576

IPSec -

--- ---- ---------------- ------ ------------------------------------------------

----

--------

-------

--------------

Idx Type Server Address Port State Tout AuthMode/Phase1/Group/Lifetime/Auth/Encr/Region

MgmtTout

RFC3576

IPSec -

--- ---- ---------------- ------ ------------------------------------------------

--------

-------

--------------

Accounting Servers

NIST SP 1800-8C: Securing Wireless Infusion Pumps

----

218

TACACS Configuration Fallback Test: Interval (in seconds)........................ 0 Authentication Servers

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

Idx

Server Address

Port

State

Tout

MgmtTout

---

----------------------

------

-------

-----

--------

Authorization Servers

Idx

Server Address

Port

State

Tout

MgmtTout

---

----------------------

------

-------

-----

--------

Accounting Servers

Idx

Server Address

Port

State

Tout

MgmtTout

---

----------------------

------

-------

-----

--------

LDAP Configuration

Local EAP Configuration User credentials database search order: Primary ..................................... Local DB

Timer: Active timeout .............................. 300

NIST SP 1800-8C: Securing Wireless Infusion Pumps

219

Configured EAP profiles:

EAP Method configuration: EAP-FAST: Server key ................................ <hidden> TTL for the PAC ........................... 10 Anonymous provision allowed ............... Yes

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

Authority ID .............................. 436973636f0000000000000000000000 Authority Information ..................... Cisco A-ID

Dns Configuration Radius port...................................... Radius secret.................................... Dns url.......................................... Dns timeout...................................... Dns Serverip..................................... Dns state........................................ Disable Dns Auth Retransmit Timeout...................... 2 Dns Acct Retransmit Timeout...................... 2 Dns Auth Mgmt-Retransmit Timeout................. 2 Dns Network Auth................................. Enable Dns Mgmt Auth.................................... Enable Dns Network Acct................................. Enable Dns RFC 3576 Auth................................ Disable

Tacacs port...................................... Tacacs secret.................................... 2 Dns url.......................................... Dns timeout...................................... Dns Serverip.....................................

NIST SP 1800-8C: Securing Wireless Infusion Pumps

220

Dns state........................................ Disable

Fallback Radio Shut configuration:

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

Fallback Radio Shut: Disabled Arp-caching: Disabled Subnet Broadcast Drop: Disabled

FlexConnect Group Summary

FlexConnect Group Summary: Count: 0 Group Name

# Aps

FlexConnect Group Detail

FlexConnect Vlan name Summary

Vlan-Name Id

Status

-------------------------------- -------

NIST SP 1800-8C: Securing Wireless Infusion Pumps

221

FlexConnect Vlan Name Detail

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

Route

Info

Number of Routes................................. 0

Destination Network

Netmask

Gateway

-------------------

-------------------

-------------------

Peer Route

Info

Number of Routes................................. 32555

Destination Network

Netmask

Gateway

-------------------

-------------------

-------------------

Qos Queue Length Info Platinum queue length............................ 100 Gold queue length................................

75

Silver queue length..............................

50

Bronze queue length..............................

25

NIST SP 1800-8C: Securing Wireless Infusion Pumps

222

Qos Profile Info Description...................................... For Voice Applications Maximum Priority................................. voice Unicast Default Priority......................... voice Multicast Default Priority....................... voice Per-SSID Rate Limits............................. Upstream

Downstream

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

Average Data Rate................................

0

0

Average Realtime Data Rate.......................

0

0

Burst Data Rate..................................

0

0

Burst Realtime Data Rate.........................

0

0

Per-Client Rate Limits........................... Upstream

Downstream

Average Data Rate................................

0

0

Average Realtime Data Rate.......................

0

0

Burst Data Rate..................................

0

0

Burst Realtime Data Rate.........................

0

0

protocol......................................... dot1p dot1p............................................ 5 Description...................................... For Video Applications Maximum Priority................................. video Unicast Default Priority......................... video Multicast Default Priority....................... video Per-SSID Rate Limits............................. Upstream

Downstream

Average Data Rate................................

0

0

Average Realtime Data Rate.......................

0

0

Burst Data Rate..................................

0

0

Burst Realtime Data Rate.........................

0

0

Per-Client Rate Limits........................... Upstream

Downstream

Average Data Rate................................

0

0

Average Realtime Data Rate.......................

0

0

Burst Data Rate..................................

0

0

Burst Realtime Data Rate.........................

0

0

NIST SP 1800-8C: Securing Wireless Infusion Pumps

223

protocol......................................... dot1p dot1p............................................ 4 Description...................................... For Best Effort Maximum Priority................................. besteffort Unicast Default Priority......................... besteffort Multicast Default Priority....................... besteffort Per-SSID Rate Limits............................. Upstream

Downstream

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

Average Data Rate................................

0

0

Average Realtime Data Rate.......................

0

0

Burst Data Rate..................................

0

0

Burst Realtime Data Rate.........................

0

0

Per-Client Rate Limits........................... Upstream

Downstream

Average Data Rate................................

0

0

Average Realtime Data Rate.......................

0

0

Burst Data Rate..................................

0

0

Burst Realtime Data Rate.........................

0

0

protocol......................................... dot1p dot1p............................................ 0 Description...................................... For Background Maximum Priority................................. background Unicast Default Priority......................... background Multicast Default Priority....................... background Per-SSID Rate Limits............................. Upstream

Downstream

Average Data Rate................................

0

0

Average Realtime Data Rate.......................

0

0

Burst Data Rate..................................

0

0

Burst Realtime Data Rate.........................

0

0

Per-Client Rate Limits........................... Upstream

Downstream

Average Data Rate................................

0

0

Average Realtime Data Rate.......................

0

0

Burst Data Rate..................................

0

0

Burst Realtime Data Rate.........................

0

0

NIST SP 1800-8C: Securing Wireless Infusion Pumps

224

protocol......................................... dot1p dot1p............................................ 1

Mac Filter Info

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

Authorization List

Authorize MIC APs against Auth-list or AAA ...... disabled Authorize LSC APs against Auth-List ............. disabled APs Allowed to Join AP with Manufacturing Installed Certificate.... yes AP with Self-Signed Certificate................ no AP with Locally Significant Certificate........ no

Load Balancing Info Aggressive Load Balancing........................ per WLAN enabling Aggressive Load Balancing Window................. 5 clients Aggressive Load Balancing Denial Count........... 3 Aggressive Load Balancing Uplink Threshold....... 50

Statistics (client-count based) Total Denied Count............................... 0 clients Total Denial Sent................................ 0 messages Exceeded Denial Max Limit Count.................. 0 times

NIST SP 1800-8C: Securing Wireless Infusion Pumps

225

None 5G Candidate Count.......................... 0 times None 2.4G Candidate Count........................ 0 times

Statistics (uplink-usage based) Total Denied Count............................... 0 clients Total Denial Sent................................ 0 messages

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

Exceeded Denial Max Limit Count.................. 0 times None 5G Candidate Count.......................... 0 times None 2.4G Candidate Count........................ 0 times

DHCP Info

DHCP Opt-82 RID Format: <AP radio MAC address> DHCP Opt-82 Format: binary

DHCP Proxy Behaviour:

disabled

Exclusion List ConfigurationUnable to retrieve exclusion-list entry

NIST SP 1800-8C: Securing Wireless Infusion Pumps

226

CDP Configuration cdp version v2

Country Channels Configuration

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

Configured Country............................. US

- United States

KEY: * = Channel is legal in this country and may be configured manually. A = Channel is the Auto-RF default in this country. . = Channel is not legal in this country. C = Channel has been configured for use by Auto-RF. x = Channel is available to be configured for use by Auto-RF. (-,-) = (indoor, outdoor) regulatory domain allowed by this country. -----------------:+-+-+-+-+-+-+-+-+-+-+-+-+-+802.11bg

:

Channels

:

1 1 1 1 1

: 1 2 3 4 5 6 7 8 9 0 1 2 3 4 -----------------:+-+-+-+-+-+-+-+-+-+-+-+-+-+US (-A

,-AB

): A * * * * A * * * * A . . .

-----------------:+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+802.11a

:

1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1

Channels

: 3 3 3 4 4 4 4 4 5 5 6 6 0 0 0 1 1 2 2 2 3 3 4 4 4 5 5 6 6 6 7 : 4 6 8 0 2 4 6 8 2 6 0 4 0 4 8 2 6 0 4 8 2 6 0 4 9 3 7 1 5 9 3

-----------------:+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+US (-AB

,-AB

): . A . A . A . A A A A A A A A A A A A A A A A A A A A A * . .

-----------------:+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+4.9GHz 802.11a

:

Channels

:

1 1 1 1 1 1 1 1 1 1 2 2 2 2 2 2 2

: 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 -----------------:+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+US (-AB

,-AB

): * * * * * * * * * * * * * * * * * * * A * * * * * A

NIST SP 1800-8C: Securing Wireless Infusion Pumps

227

-----------------:+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-

WPS Configuration Summary

Auto-Immune

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

Auto-Immune.................................... Disabled Auto-Immune by aWIPS Prevention................ Disabled

Client Exclusion Policy Excessive 802.11-association failures.......... Enabled Excessive 802.11-authentication failures....... Enabled Excessive 802.1x-authentication................ Enabled IP-theft....................................... Enabled Excessive Web authentication failure........... Enabled Maximum 802.1x-AAA failure attempts............ 3

Signature Policy Signature Processing........................... Enabled

Management Frame Protection Global Infrastructure MFP state................ DISABLED (*all infrastructure settings are overridden) AP Impersonation detection..................... Disabled Controller Time Source Valid................... False

WLAN

Client

WLAN ID

WLAN Name

Status

Protection

-------

-------------------------

---------

----------

NIST SP 1800-8C: Securing Wireless Infusion Pumps

228

1 IP_Dev No Encryption configured)

Disabled

Optional but inactive (WPA2 not

2

Enabled

Optional

IP_Dev All WPA/WPA2 PSK

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

Custom Web Configuration

Radius Authentication Method..................... PAP Cisco Logo....................................... Enabled CustomLogo....................................... None Custom Title..................................... None Custom Message................................... None Custom Redirect URL.............................. None Web Authentication Type.......................... Internal Default Logout-popup..................................... Enabled External Web Authentication URL.................. None

Configuration Per Profile:

Core dump Configuration

Core Dump upload is disabled

NIST SP 1800-8C: Securing Wireless Infusion Pumps

229

Rogue AP Configuration

Rogue Detection Security Level................... custom Rogue Pending Time............................... 180 secs Rogue on wire Auto-Contain....................... Disabled Rogue using our SSID Auto-Contain................ Disabled Valid client on rogue AP Auto-Contain............ Disabled

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

Rogue AP timeout................................. 1200 Rogue Detection Report Interval.................. 10 Rogue Detection Min Rssi......................... -90 Rogue Detection Transient Interval............... 0 Rogue Detection Client Num Thershold............. 0 Validate rogue AP against AAA.................... Disabled Rogue AP AAA validation interval................. 0 secs Total Rogues(AP+Ad-hoc) supported................ 800 Total Rogues classified.......................... 41

MAC Address

Classification

-----------------

------------------ ----- --------- -----------------------

04:bd:88:b5:2f:40

Friendly

2

0

Thu Aug 18 20:06:04 2016

04:bd:88:b5:2f:45

Friendly

2

0

Thu Aug 18 20:06:04 2016

04:bd:88:b5:2f:50

Friendly

0

0

Not Heard

04:bd:88:b5:2f:55

Friendly

0

0

Not Heard

04:bd:88:b5:4e:e0

Friendly

0

0

Not Heard

04:bd:88:b5:4e:f0

Friendly

0

0

Not Heard

04:bd:88:b5:5a:20

Unclassified

2

0

Thu Aug 18 20:06:04 2016

04:bd:88:b5:5a:21

Unclassified

2

0

Thu Aug 18 20:06:04 2016

04:bd:88:b6:0d:60

Friendly

0

0

Not Heard

04:bd:88:b6:0d:70

Friendly

0

0

Not Heard

04:bd:88:b6:0d:75

Friendly

0

0

Not Heard

04:bd:88:b6:0e:e0

Friendly

0

0

Not Heard

04:bd:88:b6:0e:f0

Friendly

0

0

Not Heard

NIST SP 1800-8C: Securing Wireless Infusion Pumps

# APs # Clients Last Heard

230

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

04:bd:88:b6:0e:f5

Friendly

0

0

Not Heard

04:bd:88:b6:10:00

Friendly

0

0

Not Heard

04:bd:88:b6:10:10

Friendly

0

0

Not Heard

04:bd:88:b6:10:15

Friendly

0

0

Not Heard

04:bd:88:b6:10:60

Friendly

2

0

Thu Aug 18 20:06:04 2016

04:bd:88:b6:10:65

Unclassified

2

0

Thu Aug 18 20:06:04 2016

04:bd:88:b6:10:70

Friendly

0

0

Not Heard

04:bd:88:b6:10:75

Friendly

0

0

Not Heard

04:bd:88:b6:10:b5

Friendly

0

0

Not Heard

62:6d:c7:27:a6:98

Unclassified

2

0

Thu Aug 18 20:06:04 2016

6c:72:20:3e:af:26

Friendly

0

0

Not Heard

6c:72:20:3e:af:28

Friendly

0

0

Not Heard

6c:72:20:3e:af:2a

Friendly

0

0

Not Heard

88:dc:96:30:d9:1b

Friendly

0

0

Not Heard

8a:dc:96:30:d9:1b

Friendly

0

0

Not Heard

9a:dc:96:30:d9:1b

Friendly

0

0

Not Heard

e0:d1:73:02:b7:ab

Friendly

0

0

Not Heard

e0:d1:73:02:b7:af

Friendly

0

0

Not Heard

e0:d1:73:02:bc:2b

Friendly

0

0

Not Heard

e0:d1:73:02:bc:2f

Friendly

0

0

Not Heard

e0:d1:73:02:f6:6b

Friendly

0

0

Not Heard

e0:d1:73:02:f6:6f

Friendly

0

0

Not Heard

e0:d1:73:02:f9:4b

Friendly

0

0

Not Heard

e0:d1:73:02:f9:4f

Friendly

0

0

Not Heard

e0:d1:73:02:fa:4b

Friendly

0

0

Not Heard

e0:d1:73:02:fa:4f

Friendly

0

0

Not Heard

e0:d1:73:02:ff:1b

Friendly

0

0

Not Heard

e0:d1:73:02:ff:1f

Friendly

0

0

Not Heard

Rogue AP RLDP Configuration

Rogue Location Discovery Protocol................ Disabled

NIST SP 1800-8C: Securing Wireless Infusion Pumps

231

RLDP Schedule Config............................. Disabled RLDP Scheduling Operation........................ Disabled RLDP Retry....................................... 1

RLDP Start Time

RLDP End Time

Day

---------------

-------------

---

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

Rogue Auto Contain Configuration

Containment Level................................ 1 monitor_ap_only.................................. false

Adhoc Rogue Configuration

Detect and report Ad-Hoc Networks................ Enabled Auto-Contain Ad-Hoc Networks..................... Disabled Total Rogues(Ad-Hoc+AP) supported ............... 800 Total Ad-Hoc entries ............................ 0

Client MAC Address

Adhoc BSSID

State

# APs

Last Heard

---------------------

------------------

-----------------

------

-------------------

Rogue Client Configuration

Validate rogue clients against AAA............... Disabled Validate rogue clients against MSE............... Disabled Total Rogue Clients supported.................... 3000 Total Rogue Clients present...................... 0

MAC Address

State

-----------------

------------------ ----- -----------------------

NIST SP 1800-8C: Securing Wireless Infusion Pumps

# APs Last Heard

232

Ignore List Configuration

MAC Address -----------------

Rogue Rule Configuration

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

Priority Match Hit Count

Rule Name

Rule state Class Type

Notify

State

-------- -------------------------------- ----------- ----------- -------- -------- ----- ---------

Media-Stream Configuration

Multicast-direct State........................... disable Allowed WLANs....................................

Stream Name Start IP Operation Status

End IP

------------- --------------------------------------- -------------------------------------- ----------------

URL.............................................. E-mail........................................... Phone............................................ Note.............................................

NIST SP 1800-8C: Securing Wireless Infusion Pumps

233

State............................................ disable

2.4G Band Media-Stream Configuration

Multicast-direct................................. Enabled Best Effort...................................... Disabled

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

Video Re-Direct.................................. Enabled Max Allowed Streams Per Radio.................... Auto Max Allowed Streams Per Client................... Auto Max Video Bandwidth.............................. 0 Max Voice Bandwidth.............................. 75 Max Media Bandwidth.............................. 85 Min PHY Rate..................................... 6000 Max Retry Percentage............................. 80

5G Band Media-Stream Configuration

Multicast-direct................................. Enabled Best Effort...................................... Disabled Video Re-Direct.................................. Enabled Max Allowed Streams Per Radio.................... Auto Max Allowed Streams Per Client................... Auto Max Video Bandwidth.............................. 0 Max Voice Bandwidth.............................. 75 Max Media Bandwidth.............................. 85 Min PHY Rate..................................... 6000 Max Retry Percentage............................. 80

Number of Clients................................ 0

NIST SP 1800-8C: Securing Wireless Infusion Pumps

234

Client Mac

Stream Name

Stream Type

Radio WLAN

QoS

-----------------

-----------

-----------

----

------ -------

----

Status

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

WLC Voice Call Statistics WLC Voice Call Statistics for 802.11b Radio

WMM TSPEC CAC Call Stats Total num of Calls in progress................. 0 Num of Roam Calls in progress.................. 0 Total Num of Calls Admitted.................... 0 Total Num of Roam Calls Admitted............... 0 Total Num of exp bw requests received.......... 0 Total Num of exp bw requests Admitted.......... 0 Total Num of Calls Rejected.................... 0 Total Num of Roam Calls Rejected............... 0 Num of Calls Rejected due to insufficent bw.... 0 Num of Calls Rejected due to invalid params.... 0 Num of Calls Rejected due to PHY rate.......... 0 Num of Calls Rejected due to QoS policy........ 0 SIP CAC Call Stats Total Num of Calls in progress................. 0 Num of Roam Calls in progress.................. 0 Total Num of Calls Admitted.................... 0 Total Num of Roam Calls Admitted............... 0 Total Num of Preferred Calls Received.......... 0 Total Num of Preferred Calls Admitted.......... 0 Total Num of Ongoing Preferred Calls........... 0 Total Num of Calls Rejected(Insuff BW)......... 0

NIST SP 1800-8C: Securing Wireless Infusion Pumps

235

Total Num of Roam Calls Rejected(Insuff BW).... 0 KTS based CAC Call Stats Total Num of Calls in progress................. 0 Num of Roam Calls in progress.................. 0 Total Num of Calls Admitted.................... 0 Total Num of Roam Calls Admitted............... 0 Total Num of Calls Rejected(Insuff BW)......... 0

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

Total Num of Roam Calls Rejected(Insuff BW).... 0

WLC Voice Call Statistics for 802.11a Radio

WMM TSPEC CAC Call Stats Total num of Calls in progress................. 0 Num of Roam Calls in progress.................. 0 Total Num of Calls Admitted.................... 0 Total Num of Roam Calls Admitted............... 0 Total Num of exp bw requests received.......... 0 Total Num of exp bw requests Admitted.......... 0 Total Num of Calls Rejected.................... 0 Total Num of Roam Calls Rejected............... 0 Num of Calls Rejected due to insufficent bw.... 0 Num of Calls Rejected due to invalid params.... 0 Num of Calls Rejected due to PHY rate.......... 0 Num of Calls Rejected due to QoS policy........ 0 SIP CAC Call Stats Total Num of Calls in progress................. 0 Num of Roam Calls in progress.................. 0 Total Num of Calls Admitted.................... 0 Total Num of Roam Calls Admitted............... 0 Total Num of Preferred Calls Received.......... 0 Total Num of Preferred Calls Admitted.......... 0 Total Num of Ongoing Preferred Calls........... 0

NIST SP 1800-8C: Securing Wireless Infusion Pumps

236

Total Num of Calls Rejected(Insuff BW)......... 0 Total Num of Roam Calls Rejected(Insuff BW).... 0 KTS based CAC Call Stats Total Num of Calls in progress................. 0 Num of Roam Calls in progress.................. 0 Total Num of Calls Admitted.................... 0 Total Num of Roam Calls Admitted............... 0

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

Total Num of Calls Rejected(Insuff BW)......... 0 Total Num of Roam Calls Rejected(Insuff BW).... 0

WLC IPv6 Summary

Global Config............................... Enabled Reachable-lifetime value.................... 300 Stale-lifetime value........................ 86400 Down-lifetime value......................... 30 RA Throttling............................... Disabled RA Throttling allow at-least................ 1 RA Throttling allow at-most................. 1 RA Throttling max-through................... 10 RA Throttling throttle-period............... 600 RA Throttling interval-option............... passthrough NS Mulitcast CacheMiss Forwarding........... Disabled NA Mulitcast Forwarding..................... Enabled IPv6 Capwap UDP Lite........................ Enabled Operating System IPv6 state................. Enabled

NIST SP 1800-8C: Securing Wireless Infusion Pumps

237

mDNS Service Summary

Number of Services.............................. 10 Mobility learning status ........................ Enabled Service-Name

LSS

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

Origin

No SP

Service-string

-------------------------------- ----

----------

-----

---------------

AirTunes

No

All

0

_raop._tcp.local.

Airplay

No

All

0

_airplay._tcp.local.

Googlecast

No

All

0

_googlecast._tcp.local.

HP_Photosmart_Printer_1 No _universal._sub._ipp._tcp.local.

All

0

HP_Photosmart_Printer_2

No

All

0

_cups._sub._ipp._tcp.local.

HomeSharing

No

All

0

_home-sharing._tcp.local.

Printer-IPP

No

All

0

_ipp._tcp.local.

Printer-IPPS

No

All

0

_ipps._tcp.local.

Printer-LPD

No

All

0

_printer._tcp.local.

Printer-SOCKET

No

All

0

_pdl-datastream._tcp.local.

* -> If access policy is enabled LSS will be ignored.

mDNS service-group Summary

Access Policy Status............................ Disabled Total number of mDNS Policies.................... 1

Number of Admin configured Policies.............. 1

Sl No Origin

Service Group Name

NIST SP 1800-8C: Securing Wireless Infusion Pumps

Description

238

--------------------------------------------

-------------------------------------

1 WLC

Default Access Policy created by WLC

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

mDNS

default-mdns-policy

profile detailed

Profile Name..................................... default-mdns-profile Profile Id....................................... 1 No of Services................................... 10 Services......................................... AirTunes Airplay Googlecast HP_Photosmart_Printer_1 HP_Photosmart_Printer_2 HomeSharing Printer-IPP Printer-IPPS Printer-LPD Printer-SOCKET

No. Interfaces Attached.......................... 0 No. Interface Groups Attached.................... 0 No. Wlans........................................ 0 No. Local Policies Attached...................... 0

mDNS AP Summary

NIST SP 1800-8C: Securing Wireless Infusion Pumps

239

Number of mDNS APs............................. 0

PMIPv6 Global Configuration

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

PMIPv6 Profile Summary

No Profile Created.

PMIPv6 MAG Statistics

PMIPv6 domain has to be configured first

EoGRE Global Configuration

Heartbeat Interval...............60 Max Heartbeat Skip Count.........3 Interface........................management

EoGRE Gateway Configuration

EoGRE Domain Configuration

Domain Name --------------

Gateways -----------------

NIST SP 1800-8C: Securing Wireless Infusion Pumps

Active Gateway --------------------

240

EoGRE Profile Configuration

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

WLAN Express Setup Information.

WLAN Express Setup - ............................ False

Flex Avc Profile summary.

Profile-Name

Number of Rules

status

============

===============

========

Flex Avc Profile Detailed Configuration.

Certificate Summary. Web Administration Certificate................... 3rd Party Web Authentication Certificate................... Locally Generated Certificate compatibility mode:.................. off Lifetime Check Ignore for MIC ................... Disable

NIST SP 1800-8C: Securing Wireless Infusion Pumps

241

Lifetime Check Ignore for SSC ................... Disable

Smart-licensing status Summary.

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

Call-home Summary.

Hotspot Icon Summary.

Unable to find Icon directory in flash.

Coredump Summary

Core Dump upload is disabled

Memory Summary -------------------------- System Memory Summary -------------------------

NIST SP 1800-8C: Securing Wireless Infusion Pumps

242

System Name:wlc Primary SW Ver:8.2.111.0 Current Time:Thu Aug 18 20:06:33 2016 System UP Time:6 days 3 hrs 49 mins 39 secs NAME: "Chassis"

, DESCR: "Cisco Wireless Controller"

PID: AIR-CTVM-K9,

VID: V01,

SN: 96NTPERK0A6

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

Total System Memory.............................. (2057560

KB) 2009 MB

Total System Free Memory......................... (909360

KB) 888 MB (44 %)

Total Memory in Buffers.......................... (1104

KB)

Total Memory in Cache............................ (266564

KB) 260 MB

Total Active Memory.............................. (511540

KB) 499 MB

Total InActive Memory............................ (238112

KB) 232 MB

Total Memory in Anon Pages....................... (481984

KB) 470 MB

Total Memory in Slab............................. (11004

KB) 10 MB

Total Memory in Page Tables...................... (2748

KB) 2 MB

WLC Peak Memory.................................. (1402280

KB) 1369 MB

WLC Virtual Memory Size.......................... (1383912

KB) 1351 MB

WLC Resident Memory.............................. (506340

KB) 494 MB

WLC Data Segment Memory.......................... (1318240

KB) 1287 MB

Total Heap Including Mapped Pages................ (399115

KB) 389 MB

Total Memory in Pmalloc Pools.................... (350174

KB) 341 MB

Total Used Memory in Pmalloc Pools............... (324913

KB) 317 MB

Total Free Memory in Pmalloc Pools............... (16706

KB) 16 MB

------------------------- Pmalloc Pools Information -------------------Index Pool-Size Chunks-In-Pool Chunks-In-Use Memory(Size/Used/Free)KB 0

16

50000

5351

5468

/4771

/697

1

64

40000

16626

6250

/4789

/1460

2

128

52800

52677

11550

/11534

/15

3

256

9400

9377

3231

/3225

/5

4

384

6000

287

2812

/670

/2142

5

512

16000

15

9500

/1507

/7992

6

1024

13100

12985

14328

/14213

/115

7

2048

1000

712

2093

/1517

/576

8

4096

1000

74

4093

/389

/3704

NIST SP 1800-8C: Securing Wireless Infusion Pumps

243

9

Raw-Pool

0

-------------------------

524

290800

/290800

/0

MBUF Information ----------------------------

Maximum number of Mbufs.......................... 24576 Number of Mbufs Free............................. 24560 Number of Mbufs In Use........................... 16

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

Mesh Configuration

Mesh Range....................................... 12000 Mesh Statistics update period.................... 3 minutes Backhaul with client access status............... disabled Backhaul with extended client access status...... disabled Background Scanning State........................ disabled Subset Channel Sync State........................ disabled Backhaul Amsdu State............................. enabled Backhaul RRM..................................... disabled Mesh Auto RF..................................... disabled

Mesh Security Security Mode................................. EAP External-Auth................................. disabled Use MAC Filter in External AAA server......... disabled Force External Authentication................. disabled LSC Only MAP Authentication................... disabled

Mesh Alarm Criteria Max Hop Count................................. 4 Recommended Max Children for MAP.............. 10 Recommended Max Children for RAP.............. 20

NIST SP 1800-8C: Securing Wireless Infusion Pumps

244

Low Link SNR.................................. 12 High Link SNR................................. 60 Max Association Number........................ 10 Association Interval.......................... 60 minutes Parent Change Numbers......................... 3 Parent Change Interval........................ 60 minutes

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

Mesh Multicast Mode.............................. In-Out Mesh CAC Mode.................................... enabled Mesh Full Sector DFS............................. enabled

Mesh Ethernet Bridging VLAN Transparent Mode..... enabled

Mesh DCA channels for serial backhaul APs........ disabled

Outdoor Ext. UNII B Domain channels(for BH)...... disabled Mesh Advanced LSC................................ disabled Advanced LSC AP Provisioning .................... disabled Open Window.................................... disabled Provision Controller........................... disabled

Mesh Slot Bias................................... enabled Mesh Convergence Method.......................... standard Mesh Channel Change Notification................. disabled Mesh Ethernet Bridging STP BPDU Allowed.......... disabled Mesh RAP downlink backhaul....................... 802.11Radio-A (Slot 1)

NIST SP 1800-8C: Securing Wireless Infusion Pumps

245

Appendix B

Sample Pump Configuration Parameters

SN=2011304 # Pump serial number - must match SN of receiving pump # SIGMA Spectrum Settings [NETWORK CONFIGURATION] # DHCP=0 DHCP disabled - IP, GATEWAY, NETMASK, and DNS must be valid

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

# DHCP=1 DHCP enabled - IP, GATEWAY, NETMASK, and DNS must be blank DHCP=1 IP= GATEWAY= NETMASK= DNS= # Leave either SIGMAGW or MULTICAST blank # SIGMAGW set to DNS name or IP address of SIGMA gateway server SIGMAGW=192.168.140.165 # MULTICAST group default is 239.237.12.87 MULTICAST= # DEVICEID set to device alias # Limited to 20 alpha-numeric characters (0-1,A-Z,a-z), blank is acceptable DEVICEID=000345 [WIFI CONFIGURATION] # BSS=0 Infrastructure mode (Access point) # BSS=1 Join or Create Ad-Hoc (peer-to-peer) # BSS=2 Join only Ad-Hoc (peer-to-peer) # BSS=3 Join any BSS=0 # SSID= set to wireless network name SSID=IP_Dev_Cert # 802.11 Mode - 'b', 'g', and/or 'a' 802.11b=1 802.11g=1

NIST SP 1800-8C: Securing Wireless Infusion Pumps

246

802.11a=1 # CHANNEL=0 search channels CHANNEL=0 # SECURITY=0 Any available security method # SECURITY=1 Open system (no-encryption) # SECURITY=2 WEP shared key # SECURITY=3 WPA pre-shared key

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

# SECURITY=4 WPA with 802.1x authentication # SECURITY=5 WEP with 802.1x authentication # SECURITY=6 LEAP # SECURITY=7 EAP-FAST SECURITY=4 # WEPKEYINDEX=0-3 WEPKEYINDEX=0 # WEPKEY may be blank or 10 (64-bit) or 26 (128-bit) hex (0-1 and a-f) characters long WEPKEY= # WPAENCRYPTION=0 Any # WPAENCRYPTION=1 WEP # WPAENCRYPTION=2 TKIP # WPAENCRYPTION=3 CCMP (AES) # WPAENCRYPTION=4 Open (no encryption) WPAENCRYPTION=3 # WPAPSK must be blank if WPA PSK is not used # WPAPSK may 64 hex (0-1 and a-f) characters long to specify a PSK # WPAPSK may be 8-63 ascii characters long to specify a passphrase WPAPSK= # 802.1X/EAP Authentication method # Set one, or more, authentication methods to 1 to enable them, all others should be 0 LEAP=0 PEAP/MSCHAPv2=0

NIST SP 1800-8C: Securing Wireless Infusion Pumps

247

EAP-TLS=1 EAP-FAST=0 # IDENTITY= 802.1X Identity (username) IDENTITY=BaxterCert # PASSWORD= 802.1X Password PASSWORD= # Certificate information follows, required for authentication modes that use a

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

certificate. # All certificates and private keys must be PEM format (base64 encoded). # Client certificate, both cert and private key are required. # Certificate and key information is not output for security reasons. # Certificate information is radio specific, so the MAC address of the Wireless Battery Module # of the attached, or soon to be attached module must match. # If the certs or keys required a password, it should be specified in the 802.1x PASSWORD field above. # The MAC address specified below must match the module connected to the pump. MAC=00:40:9d:66:db:45 CLIENTCERT=

-----BEGIN RSA PRIVATE KEY----MIIEowIBAAKCAQEAuhKvGS9womnF7tmM1IOWuzbvMct7u+TDYtoQSNEitAYe5Bjr XR+tQOT/2b08nJUjVNl91/+3t2i9qUDDU58DTKKir9dmR5ridHlaIyhts8fB7h2a rZ74YK+4/A1C2mNpmwqwDQlwWhJzJgSe5XeZF0ALTdS3LEggwpuPb6Eo2Wbnqwr0 /tbsRvaeEjwcIGOwmuy1v8TkrbSKeFt9I4B54Pcl3KsxbnnUjH7JIV9h/0nyrOKi z2P+3maogCnOwxRQp79j/IgCS3JbUBMG14gKnxorJgLuBovqpsWIYO6k/qohIpyg Vevc0UUj8XiyEun1ldT1SCXYke/I9jauLBB6OQIDAQABAoIBAHjnmw7qXG2r/Qju IywTNOYBE/tvFL9KLgsVVm96NOp0762W45hm9NSt9/ErnS7BWWvQxoyLhHyQemx3 wHOdZy9snflUJQlyAqNcFs2xf1bJ/aETa2ZVXV61z6U3mLD+16f+kdZmw7JDOr8B UZ4Y0EjjPHUeOsdzNpY9Lj6CoWBg+V3+TEo3WCqHsqHN8yoVKP30Xnfb1JMgRLf/ infhI6Qg6QKBM++vWQjlUYuM4hbQtQ6HmwWv2epu8YHFdmm3jTSrv+W8lBbY2N5D N9tZsdUJ54NHiVZTjVmAXCxSpBp3+yTOMRpnzgW0v8MLMhFanjIC5QypG712HIQx

NIST SP 1800-8C: Securing Wireless Infusion Pumps

248

gk7LZGECgYEA4vB26UpZNxsOlgzcEQP8fQ82Dk5xNjb9e7qDSD85LUppR6F4xwNs QPyFVYRemb+pQyIwn1X2SNAdRvsDwSsFVTV9ENi1PzlHbOfaBWE9/VNMaz8vCjfr teC3So6bIWllHNeoOl8d1wrTOtGZFENH/H4DoOBC7U0aoYjvtnYBplMCgYEA0eaJ mITPESmZRZI8kaCb/TrWLTZmH2SOCPgC/qVmJ2FiQ8iT3KJXJ5d8ophY84Kay4le axVUUgIdKNyvNrf038Rx0DirN+qznSKPJuMdY+tnCxaXBjTj/tSwkeiNamZOXHeH boVlReX6ONDvT+u9MkvMxDmhwBb9G4izw26a88MCgYAhqyFJLTGdPlNkqZXApIHC IA6aAsNDEtd6kspFXrPh50dFTEx54iUeYxh4/oF2d/vprNnf2cYHOXEOhdEhyHsr

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

EBt082G4dowFOUScRbgHrGMLCj21W2SKAEPROOUFCPjqVYhs2I25yK5b7Jq0aeL1 L9Dj/kGPqT/JNWKzBEDsZwKBgQDFNt5BN0d20Kb5/xR5n3Xwz788a8g35rqtIplt uOnqRk2Vcne67a0FvgeUnZ+17BiU9FSKOFgpVWMgaXkW6HBjbqehBB2bRCHOmhH2 b53Fq//9IxRy+G7fl+busJluRwGJT6Un6p3kttgLWgQAC3aQMzgJhjy7xt25aQ+9 p8ZfEQKBgB6jQAT31FxvPFHyjU4NdFeogJd2c2nFbkC7aqOEPKNG9Nbzn/VVWh7x Rx7Axua3D2OYrCH7V1NcR9X1dInpyj/hYXc5/VdtLZ2yhEc2GiG/jfgNWk2W2BZd 2NLf54bgV67lkC2yKMK/5wBru+V73WmqvWfQ4KsMesLLBBzMRvJa -----END RSA PRIVATE KEY-----

-----BEGIN CERTIFICATE----MIIFWzCCBEOgAwIBAgIQAr0FxoUrLR0mLxVp3m/RJzANBgkqhkiG9w0BAQsFADBx MQswCQYDVQQGEwJVUzEVMBMGA1UEChMMRGlnaUNlcnQgSW5jMRkwFwYDVQQLExB3 d3cuZGlnaWNlcnQuY29tMTAwLgYDVQQDEydEaWdpQ2VydCBUZXN0IEludGVybWVk aWF0ZSBSb290IENBIFNIQTIwHhcNMTcwMzE1MDAwMDAwWhcNMTgwMzE1MTIwMDAw WjCBiDELMAkGA1UEBhMCVVMxCzAJBgNVBAgTAk1EMRIwEAYDVQQHEwlSb2Nrdmls bGUxNzA1BgNVBAoTLk5hdGlvbmFsIEluc3RpdHV0ZSBvZiBTdGFuZGFyZHMgYW5k IFRlY2hub2xvZ3kxDjAMBgNVBAsTBU5DQ29FMQ8wDQYDVQQDEwZCYXh0ZXIwggEi MA0GCSqGSIb3DQEBAQUAA4IBDwAwggEKAoIBAQC6Eq8ZL3CiacXu2YzUg5a7Nu8x y3u75MNi2hBI0SK0Bh7kGOtdH61A5P/ZvTyclSNU2X3X/7e3aL2pQMNTnwNMoqKv 12ZHmuJ0eVojKG2zx8HuHZqtnvhgr7j8DULaY2mbCrANCXBaEnMmBJ7ld5kXQAtN 1LcsSCDCm49voSjZZuerCvT+1uxG9p4SPBwgY7Ca7LW/xOSttIp4W30jgHng9yXc qzFuedSMfskhX2H/SfKs4qLPY/7eZqiAKc7DFFCnv2P8iAJLcltQEwbXiAqfGism Au4Gi+qmxYhg7qT+qiEinKBV69zRRSPxeLIS6fWV1PVIJdiR78j2Nq4sEHo5AgMB AAGjggHVMIIB0TAfBgNVHSMEGDAWgBSJVf2JvOIQPPttTh8w+fmCi1xh4jAdBgNV HQ4EFgQU3PsIuQqjWZ2eFYrcKNhdYi7Rf1owEQYDVR0RBAowCIIGQmF4dGVyMA4G

NIST SP 1800-8C: Securing Wireless Infusion Pumps

249

A1UdDwEB/wQEAwIFoDAdBgNVHSUEFjAUBggrBgEFBQcDAQYIKwYBBQUHAwIwgZUG A1UdHwSBjTCBijBDoEGgP4Y9aHR0cDovL2NybDN0ZXN0LmRpZ2ljZXJ0LmNvbS9E aWdpQ2VydFRlc3RJbnRlcm1lZGlhdGVTSEEyLmNybDBDoEGgP4Y9aHR0cDovL2Ny bDN0ZXN0LmRpZ2ljZXJ0LmNvbS9EaWdpQ2VydFRlc3RJbnRlcm1lZGlhdGVTSEEy LmNybDAhBgNVHSAEGjAYMAwGCmCGSAGG/WxjAQEwCAYGZ4EMAQICMIGDBggrBgEF BQcBAQR3MHUwKAYIKwYBBQUHMAGGHGh0dHA6Ly9vY3NwdGVzdC5kaWdpY2VydC5j b20wSQYIKwYBBQUHMAKGPWh0dHA6Ly9jYWNlcnRzLmRpZ2ljZXJ0LmNvbS9EaWdp

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

Q2VydFRlc3RJbnRlcm1lZGlhdGUtU0hBMi5jcnQwDAYDVR0TAQH/BAIwADANBgkq hkiG9w0BAQsFAAOCAQEAe7Rc6PbIfEjSQpCZ3UpZ7zqWruov44nmSKvR/X4MJITM z9k3S+TzGOGYnq7bHBF1mjLt0l5K/BDWSG6LY5clSYJuGCbC/dSNFk9G+lzBKs5S 5xJxk8HeAt4OHOWmtEhZ7S4np7zUBcRu1koHbw4vW/lYJBvxRF1Sdd0ypyBP4X81 D2mX+LmFo2rlLSExurr5rd1s6Pna2FRBEjoyM78ID9AmKENqeioDi+hxGLlQROOt y7aZU8yWcec7nad9iUGO/pMDdhbWexpvp4CBihxYkUMQcf8RaqTkJM8fLAdvPq9P oQuBuMi+qPtI3WkTgfwr49usBzgbrdNPc/5MRQEz8Q== -----END CERTIFICATE-----

# Client certificate expiration date, GMT in the format: MM/DD/YYYY HH:MM:SS. CLIENTCERTEXPIRE= # Trusted certificates, maximum of 5. TRUSTEDCERTS=

-----BEGIN CERTIFICATE----MIIGSTCCBTGgAwIBAgIEM6qqqjANBgkqhkiG9w0BAQsFADBkMQswCQYDVQQGEwJV UzEVMBMGA1UEChMMRGlnaUNlcnQgSW5jMRkwFwYDVQQLExB3d3cuZGlnaWNlcnQu Y29tMSMwIQYDVQQDExpEaWdpQ2VydCBUZXN0IFJvb3QgQ0EgU0hBMjAeFw0wNjEx MTAwMDAwMDBaFw0zMTExMTAwMDAwMDBaMHExCzAJBgNVBAYTAlVTMRUwEwYDVQQK EwxEaWdpQ2VydCBJbmMxGTAXBgNVBAsTEHd3dy5kaWdpY2VydC5jb20xMDAuBgNV BAMTJ0RpZ2lDZXJ0IFRlc3QgSW50ZXJtZWRpYXRlIFJvb3QgQ0EgU0hBMjCCASIw DQYJKoZIhvcNAQEBBQADggEPADCCAQoCggEBAJiahU+gQ8Brmcov1LwvynLKgxMc buqjeyYeiDEUXtTEJKoPm1Pc5YE39fBY1ydwaBJ6k3LbLZM+zqw2pCXwaf4LBhLv t4ppHMfXlgI2IVpWibSYVcvJ4waD09AQ47u/SQhDHSVf17HRUIs1tIw+MMpMyGH0 9YzgI/ZI5KTWBY+nlnz9t1/RpPdcJfAWin3T/s7xNu364OFDURX+3Rxb7bVnV1xI

NIST SP 1800-8C: Securing Wireless Infusion Pumps

250

GZUwQx23GGcSnypsflr1rBc2yvXaUnwl4DbQMUo10tdZtd1wZNQE3C1L3MXndvn0 WdFB4cM6kQlSky0RFW+TJqQIMmb29n09P/ez7Ipo0cpV3vlBAC0DWm2z/FMCAwEA AaOCAvQwggLwMA4GA1UdDwEB/wQEAwIBhjCCAcYGA1UdIASCAb0wggG5MIIBtQYL YIZIAYb9bAEDAAIwggGkMDoGCCsGAQUFBwIBFi5odHRwOi8vd3d3LmRpZ2ljZXJ0 LmNvbS9zc2wtY3BzLXJlcG9zaXRvcnkuaHRtMIIBZAYIKwYBBQUHAgIwggFWHoIB UgBBAG4AeQAgAHUAcwBlACAAbwBmACAAdABoAGkAcwAgAEMAZQByAHQAaQBmAGkA YwBhAHQAZQAgAGMAbwBuAHMAdABpAHQAdQB0AGUAcwAgAGEAYwBjAGUAcAB0AGEA

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

bgBjAGUAIABvAGYAIAB0AGgAZQAgAEQAaQBnAGkAQwBlAHIAdAAgAEMAUAAvAEMA UABTACAAYQBuAGQAIAB0AGgAZQAgAFIAZQBsAHkAaQBuAGcAIABQAGEAcgB0AHkA IABBAGcAcgBlAGUAbQBlAG4AdAAgAHcAaABpAGMAaAAgAGwAaQBtAGkAdAAgAGwA aQBhAGIAaQBsAGkAdAB5ACAAYQBuAGQAIABhAHIAZQAgAGkAbgBjAG8AcgBwAG8A cgBhAHQAZQBkACAAaABlAHIAZQBpAG4AIABiAHkAIAByAGUAZgBlAHIAZQBuAGMA ZQAuMA8GA1UdEwEB/wQFMAMBAf8wOAYIKwYBBQUHAQEELDAqMCgGCCsGAQUFBzAB hhxodHRwOi8vb2NzcHRlc3QuZGlnaWNlcnQuY29tMIGIBgNVHR8EgYAwfjA9oDug OYY3aHR0cDovL2NybDN0ZXN0LmRpZ2ljZXJ0LmNvbS9EaWdpQ2VydFRlc3RSb290 Q0FTSEEyLmNybDA9oDugOYY3aHR0cDovL2NybDR0ZXN0LmRpZ2ljZXJ0LmNvbS9E aWdpQ2VydFRlc3RSb290Q0FTSEEyLmNybDAdBgNVHQ4EFgQUiVX9ibziEDz7bU4f MPn5gotcYeIwHwYDVR0jBBgwFoAU9kZ+Gxa7N5lj9z/YhSzkyepYDx4wDQYJKoZI hvcNAQELBQADggEBALFxPxkcHgaXBuoZ10FGWsq3bybGnxC6llfDETcWVrPajudx asm8EXOTSVnqKNIXZTlm1BY0chhnVGA3YyNN7XF7XrT1HtRH5NDhWO2lzFEGSFLw hlCiGQBuzKOelbBWDhpN7icm+Y/u+DPaK6oFu0tX/u9kPzoc8OYSBe412sHAD1/l kUDPAEO4yHSXDnoe0fhk24/yCuO6Wc+mMe7YXzEkq8pOEWjNw/9E1dsP20L7jD3F 97q5uVNe1wEaeE3U5Eq1xKUBdyQqitinpTv/yo/UPTDLpfjBmK2nh2HK6r0RH+YC OicqQ99N+q6YeAlhejLa7+7FkKYKK1YEAbE1Icc= -----END CERTIFICATE-----

-----BEGIN CERTIFICATE----MIIDpjCCAo6gAwIBAgIBMzANBgkqhkiG9w0BAQsFADBkMQswCQYDVQQGEwJVUzEV MBMGA1UEChMMRGlnaUNlcnQgSW5jMRkwFwYDVQQLExB3d3cuZGlnaWNlcnQuY29t MSMwIQYDVQQDExpEaWdpQ2VydCBUZXN0IFJvb3QgQ0EgU0hBMjAeFw0wNjExMTAw MDAwMDBaFw0zMTExMTAwMDAwMDBaMGQxCzAJBgNVBAYTAlVTMRUwEwYDVQQKEwxE aWdpQ2VydCBJbmMxGTAXBgNVBAsTEHd3dy5kaWdpY2VydC5jb20xIzAhBgNVBAMT

NIST SP 1800-8C: Securing Wireless Infusion Pumps

251

GkRpZ2lDZXJ0IFRlc3QgUm9vdCBDQSBTSEEyMIIBIjANBgkqhkiG9w0BAQEFAAOC AQ8AMIIBCgKCAQEA0DLGgpMXqI2YZ15ULS61yqyqiBMpmRtM9/w/1pqoA/GEri19 VMFuvtPTWgu9IQf0dQsRMy2d8V4INSj43YyQeXnxPzanTSqza95yoH/h4xUM/pNq AlXlO8c+cYMyCDzTQ0vrEWcvPZOtXYABac9E9ceT015RdD5pORjMwTcb6NxydZr8 nRd9/J66L4R17IKvTU74IwA6fwNd0UnXbhVhGdeEAe+eIEvJ5WlWxDeS6ZdZuSZv h24QxhxpucTzSq81HHCHw4a1kOel2oqlDlUY698atS0nxfw3IR30heQ/g793Mce9 SX9u2dPPAZtSaW8/38TwKbNOa9zkRFn7oF+cZQIDAQABo2MwYTAOBgNVHQ8BAf8E

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

BAMCAYYwDwYDVR0TAQH/BAUwAwEB/zAdBgNVHQ4EFgQU9kZ+Gxa7N5lj9z/YhSzk yepYDx4wHwYDVR0jBBgwFoAU9kZ+Gxa7N5lj9z/YhSzkyepYDx4wDQYJKoZIhvcN AQELBQADggEBAAeQacFm1sFPOIEvXDVi3IH2RKF7he0p/M0bK2Soj137LMf+ctpM 3bFKJPY97YIE0g7T1qgR8TN2sK0moumMTPjWCdFWJyN4yakS6tPIWEG2XobJ9H1r iuVXLKd2M/1yhqUyt1o5KtbOGQXLFd3qdp4A1tcXuK2wyMTiSCYS3Uow61JdEw6M eyrMIpZl9GtvaXTz6LdnozAbhKC7bVUy7ob0T4E03fQ8hIQCNPupvY7Db1/XmIw8 QWVd6AOH7EE3P8xbWOvcTWZ5XbstWY014GeJFXZ7YreaAg8sYa6CzasuHkr/rxeZ 8yzOmCTTTSPk5Ju5bTfAyEpgkl5fDvntJQg= -----END CERTIFICATE-----

NIST SP 1800-8C: Securing Wireless Infusion Pumps

252

Appendix C

Acronyms

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

AAMI

Advancement of Medical Instrumentation

AES

Advanced Encryption Standard

ANSI

American National Standards Institute

AP

Access Point

APT

Advanced Persistent Threat

ASA

Adaptive Security Appliance

ASM

Alaris System Maintenance

ATP:N

Advanced Threat Protection: Network

BD

Becton, Dickinson and Company

CAPWAP

Control and Provisioning of Wireless Access Points

CFC

Cybersecurity Framework Core

CFR

Code of Federal Regulations

CIO

Chief Information Officer

CISO

Chief Information Security Officer

COI

Community of Interest

CRADA

Cooperative Research and Development Agreement

DCS:SA

Data Center Security: Server Advanced

DDoS

Distributed Denial of Service

DHCP

Dynamic Host Configuration Protocol

DNS

Domain Name System

DoS

Denial of Service

EAP

Extensible Authentication Protocol

EHR

Electronic Health Record

FDA

Food and Drug Administration

FIPS

Federal Information Processing Standards

FTP

File Transfer Protocol

HDO

Healthcare Delivery Organization

HIDS

Host Intrusion Detection System

HIPAA

Health Insurance Portability and Accountability Act

HIPS

Host Intrusion Prevention System

HTTPS

Hypertext Transfer Protocol Secure

NIST SP 1800-8C: Securing Wireless Infusion Pumps

253

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

ICS-CERT

Industrial Control Systems Cyber Emergency Response Team

IDS

Intrusion Detection System

IEC

International Electrotechnical Commission

IEEE

Institute of Electrical and Electronics Engineers

IoC

Indicator of Compromise

IP

Internet Protocol

IPS

Intrusion Prevention System

ISE

Identity Services Engine

ISO

International Standards Organization

IT

Information Technology

ITAM

Information Technology Asset Management

KRACK

Key Reinstallation Attack

LAN

Local Area Network

LDAP

Lightweight Directory Access Protocol

LVP

Large Volume Pump

MAC

Media Access Control

MAUDE

Manufacturer and User Facility Device Experience

MDISS

Medical Device Innovation, Safety & Security Consortium

MDRAP

Medical Device Risk Assessment Platform

MSSP

Managed Security Service Provider

NAT

Network Address Translation

NCCoE

National Cybersecurity Center of Excellence

NIST

National Institute of Standards and Technology

NVD

National Vulnerability Database

OSPF

Open Shortest Path First

PAC

Process Access Control

PCU

Patient Care Unit

PHI

Protected Health Information

PKI

Public Key Infrastructure

PSK

Pre-Shared Key

RADIUS

Remote Authentication Dial-In User Service

RDP

Remote Desktop Protocol

NIST SP 1800-8C: Securing Wireless Infusion Pumps

254

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

RFID

Radio-Frequency Identification

RMF

Risk Management Framework

RTLS

Real-Time Locating Systems

SD

Secure Digital

SEP

Symantec Endpoint Protection

SIEM

Security Information and Events Management

SOC

Security Operations Center

SP

Special Publication

SSID

Service Set Identifier

SSO

Single Sign-On

TCP

Transmission Control Protocol

TIR

Technical Information Report

TLS

Transport Layer Security

U.S.

United States

URL

Uniform Resource Locator

USB

Universal Serial Bus

VLAN

Virtual Local Area Network

WEP

Wired Equivalent Privacy

WLC

Wireless LAN Controller

WPA

Wi-Fi Protected Access

WPA2

Wi-Fi Protected Access II

NIST SP 1800-8C: Securing Wireless Infusion Pumps

255

Appendix D

References

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

[1]

J. Moy, OSPF Version 2, Internet Engineering Task Force (IETF) Network Working Group Request for Comments (RFC) 2328, April 1998. https://www.ietf.org/rfc/rfc2328.txt [accessed 2/7/18].

[2]

Cisco Adaptive Security Virtual Appliance (ASAv) Quick Start Guide, 9.6, Cisco [Web site], http://www.cisco.com/c/en/us/td/docs/security/asa/asa96/asav/quick-start/asav-quick/introasav.html [accessed 2/7/18].

[3]

D. Bider and M. Baushke, SHA-2 Data Integrity Verification for the Secure Shell (SSH) Transport Layer Protocol, Internet Engineering Task Force (IETF) Request for Comments (RFC) 6668, July 2012. https://tools.ietf.org/html/rfc6668 [accessed 2/7/18].

[4]

J. Postel, Internet Control Message Protocol: DARPA Internet Program Protocol Specification, Internet Engineering Task Force (IETF) Network Working Group Request for Comments (RFC) 792, September 1981. https://tools.ietf.org/html/rfc792 [accessed 2/7/18].

[5]

J. Case, M. Fedor, M. Schoffstall, and J. Davin, A Simple Network Management Protocol (SNMP), Internet Engineering Task Force (IETF) Network Working Group Request for Comments (RFC) 1157, May 1990. https://tools.ietf.org/html/rfc1157 [accessed 2/7/18].

[6]

R. Droms, Dynamic Host Configuration Protocol, Internet Engineering Task Force (IETF) Network Working Group Request for Comments (RFC) 2131, March 1997. https://www.ietf.org/rfc/rfc2131.txt [accessed 2/7/18].

[7]

Institute of Electrical and Electronics Engineers (IEEE), Bridges and Bridged Networks, IEEE 802.1Q, 2014. http://www.ieee802.org/1/pages/802.1Q-2014.html [accessed 2/7/18].

[8]

Catalyst 3650 Switch Getting Started Guide, Cisco [Web site], http://www.cisco.com/c/en/us/td/docs/switches/lan/catalyst3650/hardware/quick/guide/cat3 650_gsg.html [accessed 2/7/18].

[9]

Institute of Electrical and Electronics Engineers (IEEE), Part 11: Wireless LAN Medium Access Control (MAC) and Physical Layer (PHY) specifications: Amendment 6: Medium Access Control (MAC) Security Enhancements, 802.11i, 2004. http://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=1318903 [accessed 2/7/18].

NIST SP 1800-8C: Securing Wireless Infusion Pumps

256

This publication is available free of charge from: https://doi.org/10.6028/NIST.SP.1800-8.

[10]

Virtual Wireless LAN Controller Deployment Guide 8.2, Cisco [Web site], http://www.cisco.com/c/en/us/td/docs/wireless/technology/mesh/82/b_Virtual_Wireless_LAN_Controller_Deployment_Guide_8-2.html [accessed 2/7/18].

[11]

D. Mills, J. Martin, Ed., J. Burbank, and W. Kasch, Network Time Protocol Version 4: Protocol and Algorithms Specification, Internet Engineering Task Force (IETF) Request for Comments (RFC) 5905, June 2010. https://www.ietf.org/rfc/rfc5905.txt [accessed 2/7/18].

[12]

U.S. Department of Commerce. Announcing the Advanced Encryption Standard (AES), Federal Information Processing Standards (FIPS) Publication 197, November 2001. http://nvlpubs.nist.gov/nistpubs/FIPS/NIST.FIPS.197.pdf [accessed 2/7/18].

[13]

Cisco Wireless Controller Configuration Guide, Release 8.0, Cisco [Web site], http://www.cisco.com/c/en/us/td/docs/wireless/controller/8-0/configurationguide/b_cg80.html [accessed 2/7/18].

[14]

D. Simon, B. Aboba, and R. Hurst, The EAP-TLS Authentication Protocol, Internet Engineering Task Force (IETF) Network Working Group Request for Comments (RFC) 5216, March 2008. https://www.ietf.org/rfc/rfc5216.txt [accessed 2/7/18].

[15]

C. Rigney, S. Willens, A. Rubens, and W. Simpson, Remote Authentication Dial In User Service (RADIUS), Internet Engineering Task Force (IETF) Network Working Group Request for Comments (RFC) 2865, June 2000. https://tools.ietf.org/html/rfc2865 [accessed 2/7/18].

[16]

S. Santesson, M. Myers, R. Ankney, A. Malpani, S. Galperin, and C. Adams, X.509 Internet Public Key Infrastructure Online Certificate Status Protocol – OCSP, Internet Engineering Task Force (IETF) Request for Comments (RFC) 6960, June 2013. https://tools.ietf.org/html/rfc6960 [accessed 2/7/18].

[17]

Symantec™ Data Center Security: Server, Monitoring Edition, and Server Advanced 6.7 MP1 Planning and Deployment Guide, Symantec [Web site], http://help.symantec.com/cs/DCS6.7/DCS6_7/v118490468_v110163010/Installing-DataCenter-Security:-Server-Advanced-6.7-or-6.7-MP1/?locale=EN_US [accessed 2/7/18].

NIST SP 1800-8C: Securing Wireless Infusion Pumps

257

Related documents

Record · ID 2854 · SHA-256 b7be06a7383dd439
Retrieved via Conceptio: every document is proof-bundled with source, license, and retrieval metadata.
Bring this data into your agent: Connect via MCP or API · 20 free credits to start · no card required