ECMA-350 3rd Edition / December 2006
Data Interchange on 130 mm Rewritable and Write Once Read Many Ultra Density Optical (UDO) Disk Cartridges - Capacity: 30 Gbytes per Cartridge First Generation
Standard ECMA-350 3rd Edition / December 2006
Data Interchange on 130 mm Rewritable and Write Once Read Many Ultra Density Optical (UDO) Disk Cartridges - Capacity: 30 Gbytes per Cartridge First Generation
.
Ecma International
Rue du Rhône 114
CH-1204 Geneva
T/F: +41 22 849 6000/01
www.ecma-international.org
Brief history
Ecma Technical Committee TC31 was established in 1984 for the standardization of Optical Disks and Optical Disk Cartridges (ODC). Since its establishment, the Committee has made major contributions to ISO/IEC JTC1/SC23 toward the development of International Standards for optical disks with a diameter of 80 mm, 90 mm, 120 mm, 130 mm, 300 mm and 356 mm. Numerous standards have been developed by TC31 and published by Ecma, almost all of which have also been adopted by ISO/IEC under the fast-track procedure as International Standards. The following Ecma Standards for 130 mm disks have been published by Ecma and adopted by ISO/IEC JTC1. ECMA-153 (1991) (ISO/IEC 11560)
Information Interchange on 130 mm Optical Disk Cartridges of the Write Once, Read Multiple (WORM) Type, using the Magneto-Optical Effect
ECMA-183 (1992) (ISO/IEC 13481)
Data Interchange on 130 mm Optical Disk Cartridges - Capacity 1 Gbyte
ECMA-184 (1992) (ISO/IEC 13549)
Data Interchange on 130 mm Optical Disk Cartridges - Capacity 1,3 Gbytes
ECMA-195 (1995) (ISO/IEC 13842)
Data Interchange on 130 mm Optical Disk Cartridges - Capacity 2 Gbytes
ECMA-238 (1996) (ISO/IEC 15486)
Data Interchange on 130 mm Optical Disk Cartridges of Type WORM (Write Once Read Many) Using Irreversible Effects - Capacity: 2,6 Gbytes per Cartridge
ECMA-280 (1998) (ISO/IEC 18093)
Data Interchange on 130 mm Optical Disk Cartridges of Type WORM (Write Once Read Many) Using Irreversible Effects - Capacity: 5,2 Gbytes per Cartridge
ECMA-322 (2001) (ISO/IEC 22092)
Data Interchange on 130 mm Magneto-Optical Disk Cartridges - Capacity: 9,1 Gbytes per Cartridge
This present Ecma Standard specifies two types of double-sided ODCs; Rewritable (Type RW) and Write Once Read Many (Type WORM), both using thermo-optical Phase Change effects.
This Ecma Standard has been adopted by the General Assembly of December 2006.
Table of contents
Sect ion 1 - G eneral
1
1
Scope
1
2
Co n f o rman ce
1
2.1
O ptic al dis k
1
2.2
G ener ating s ys tem
1
2.3
Rec eiving s ys tem
2
2.4
Com patibility s tatem ent
2
3
Ref erence
2
4
Def in it ions
2
4.1
as ym m etr y
2
4.2
band
2
4.3
c as e
2
4.4
Cas e Ref er enc e Plane
2
4.5
Channel bit
2
4.6
Clam ping Zone
2
4.7
c over layer
2
4.8
Cyc lic Redundanc y Code ( CRC)
2
4.9
Data f ield
2
4.10
Def ec t Managem ent
3
4.11
Dis k Ref er enc e Plane
3
4.12
entranc e s ur f ac e
3
4.13
Er r or Cor r ec tion Code ( ECC)
3
4.14
f ield
3
4.15
f or m at
3
4.16
hub
3
4.17
inter leaving
3
4.18
land and gr oove
3
4.19
m ar k
3
4.20
Mir ror Ar ea
3
4.21
optic al dis k
3
4.22
optic al dis k c ar tr idge ( O DC)
3 -i-
4.23
Phas e Change
3
4.24
Phys ic al Bloc k Addr es s ( PBA)
4
4.25
Phys ic al T r ac k
4
4.26
r ead power
4
4.27
r ec or ding layer
4
4.28
Rec or ding T r ac k
4
4.29
Reed- Solom on c ode
4
4.30
s ec tor
4
4.31
s pac e
4
4.32
s pindle
4
4.33
s ubs trate
4
4.34
tr ac k
4
4.35
tr ac k pitc h
4
4.36
Us er Area
4
4.37
wobble
4
4.38
wr ite- inhibit hole
4
4.39
zone
5
5
Co n v en t io n s an d n o t at io n s
5
5.1
Repr es entation of num ber s
5
5.2
Nam es
5
6
Acronyms
5
7
G en eral d escript ion
6
8
G en eral requ iremen t
6
Envir onm ents 8.1 T es t envir onm ent 8.1.1 O perating envir onm ent 8.1.2 8.1.3 Stor age envir onm ent 8.1.4 T r ans por tation
6 6 7 7 7
8.2
T em peratur e s hoc k
7
8.3
Saf ety r equir em ents
7
8.4
F lam m ability
7
Ref eren ce Driv e
8
9.1
O ptic al s ys tem
8
9.2
O ptic al beam
9
9.3
Read Channel
9
9.4
T r ac k ing
9
9
- ii -
9.5
Rotation of the dis k
9
Sect io n 2 - M echanical and physical charact erist ics
10
10
10
Dimensional and physical charact erist ics of t he case
10.1
G ener al des c r iption of the c as e
10
10.2
Relations hip of Sides A and B
10
10.3
Ref er enc e ax es and c as e r ef er enc e planes
10
10.4
Cas e dr awings
10
10.5 Dim ens ions of the c as e 10.5.1 O ver all dim ens ions 10.5.2 Loc ation hole 10.5.3 Alignm ent hole 10.5.4 Sur f ac es on Cas e Ref er enc e Planes P 10.5.5 Ins er tion s lots and detent f eatur es 10.5.6 G ripper s lots 10.5.7 W r ite- inhibit holes 10.5.8 Media identif ic ation s ens or holes 10.5.9 Head and m otor window 10.5.10 Shutter s 10.5.11 Slots f or s hutter opener 10.5.12 Slots to pr event ins er tion into a MO - drive 10.5.13 Us er label ar eas
10 10 11 11 12 13 13 13 14 15 15 15 16 16
10.6 Mec hanic al c har ac ter is tic s 10.6.1 Mater ials 10.6.2 Mas s 10.6.3 Edge dis tor tion 10.6.4 Com plianc e 10.6.5 Shutter opening f or c e
16 16 16 16 16 17
10.7
Dr op tes t
17
10.8
Elec tr o- s tatic dis c har ge tes t
17
11
Dimensional, mechanical, and physical charact eristics of the disk
29
11.1
G ener al des c r iption of the dis k
29
11.2
Ref er enc e ax is and plane of the dis k
29
11.3 Dim ens ions of the dis k 11.3.1 Hub dim ens ions 11.3.2 Cover layer dim ens ions
29 29 30
11.4 Mec hanic al c har ac ter is tic s 11.4.1 Mater ial 11.4.2 Mas s 11.4.3 Mom ent of iner tia 11.4.4 Im balanc e 11.4.5 Ax ial def lec tion
32 32 32 32 32 32 - iii -
11.4.6 Ax ial ac c eler ation 11.4.7 Radial r unout 11.4.8 Radial ac c eler ation 11.4.9 T ilt 11.4.10 Ax ial dam ping
32 32 33 33 33
11.5 O ptic al c har ac ter is tic s 11.5.1 Index of r ef r ac tion 11.5.2 T hic k nes s 11.5.3 Bir ef r ingenc e 11.5.4 Ref lec tanc e
33 33 33 34 34
12
34
Int erface bet w een cart ridge and driv e
12.1
Clam ping m ethod
34
12.2
Clam ping f orc e
34
12.3
Capture c ylinder
35
12.4
Dis k pos ition in oper ating c ondition
35
Sect io n 3 - F o rmat o f in f ormat io n
37
13
T rack and Header geomet ry
37
13.1
T r ac k and Header s hape
37
13.2
W obble gr oove
38
13.3
Mir ror Ar ea
38
13.4
Direc tion of s pir al
38
13.5
T r ac k pitc h
38
13.6
Phys ic al T r ac k num ber
38
14
T rack f o rmat
40
14.1
Phys ic al T r ac k layout
40
14.2
Phys ic al Bloc k Addr es s ( PBA)
40
14.3
Sec tor s with Mir r or Ar ea
43
14.4
Radial alignm ent
43
15
Sect or f ormat
43
Sec tor layout
43
15.2 IDL, IDG 15.2.1 Addr es s Mar k ( AM) 15.2.2 ID
45 45 45
15.3
Blank f ields
46
15.4
Q uadr atur e W obble Mar k s ( Q W M)
46
15.5
G ap
46
15.6
G uard
47
15.1
- iv -
15.7
Verif y and Pr otec t ( VAP)
47
15.8
VFO 1, VFO 2
48
15.9
Sync
48
15.10 Data f ield 15.10.1 Us er data bytes 15.10.2 CRC and ECC bytes 15.10.3 Contr ol bytes 15.10.4 Res ync bytes 15.10.5 Ref er enc e byte
48 49 49 49 49 49
15.11
Pos tam ble ( PA)
49
15.12
Buf f er
49
15.13
T r ans ition Ar ea ( T A)
50
16
Reco rd ing co d es
50
16.1
Pr ef orm atted Header
50
16.2
Data f ield
50
17 17.1
F o rmat t ed Zo n e
52
G ener al des c r iption of the Form atted Zone
52
17.2 Divis ion of the For m atted Zone 17.2.1 Lead- in Zone 17.2.2 Read Foc us O f f s et ( RFO ) Zones 17.2.3 Read Ref er enc e Zones 17.2.4 Manuf ac tur er Zones 17.2.5 SDI Zones 17.2.6 DDS Zones 17.2.7 PDL3 Zone 17.2.8 W r ite Power Calibr ation Zone 17.2.9 Us er Zones 17.2.10 Lead- out Zone
52 56 56 56 56 57 57 57 57 58 58
17.3
58
Dr ive tes t data patter ns
17.4 SDI Zones us age 17.4.1 SDI am endm ent 17.4.2 LBA Contr ol Bytes in SDI s ec tors 17.4.3 Par am etr ic c onditions 17.4.4 Spec if ic Dis k Inf or m ation
59 59 60 60 60
17.5 DDS Z ones Us age 17.5.1 DDS Am endm ent 17.5.2 LBA Contr ol Bytes in DDS s ec tor s 17.5.3 DDS inf or m ation
60 60 61 61
18
61
18.1
L ayo u t o f t h e User Zo n es G ener al des c r iption of the Us er Zones -v-
61
18.2
Divis ions of the Us er Zones
61
18.3
Us er Area
61
18.4 Def ec t Managem ent Ar ea ( DMA) 18.4.1 Pr im ar y Def ec t Lis t ( PDL) Ar ea 18.4.2 Sec ondar y Def ec t Lis t ( SDL) Ar ea 18.4.3 SDL Duplic ate Pages ( SDLDP) Ar ea 18.4.4 Pr im ar y Spar es Ar ea ( PSA) 18.4.5 Sec ondar y Spar es Ar ea ( SSA)
64 64 64 64 64 65
18.5
65
19 19.1
Dis k Def inition Str uc tur e ( DDS) Def ect M anagement in t he Rew rit able ( RW ) and W rit e O nce Read M any ( W O RM ) Z on es
67
Initialization of the dis k
67
19.2 Cer tif ic ation 19.2.1 Slipping Algor ithm 19.2.2 Linear Replac em ent Algor ithm
67 67 68
19.3
Dis k not c er tif ied
68
19.4
W r ite proc edur e
69
19.5
Pr im ar y Def ec t Lis t ( PDL) f or m at and c ontent
69
19.6
Sec ondar y Def ec t Lis t ( SDL) f or m at and c ontent
70
Sect io n 4 - Charact erist ics of embossed inf ormat ion
72
20
72
20.1
Emb o ssed in f o rmat io n – M et h o d o f t est in g Envir onm ent
72
20.2 Us e of the Ref er enc e Dr ive 20.2.1 O ptic s and m ec hanic s 20.2.2 Read power 20.2.3 Read Channel 20.2.4 T r ac k ing 20.2.5 Ax ial f oc us of f s et optim ization
72 72 72 72 72 72
20.3
72
21
Def inition of s ignals Sign als f ro m g ro o v es an d lan d s
73
21.1
Ratio of gr oove to land s ignal
73
21.2
Ratio of gr oove/land to Mir r or Ar ea s ignal
74
21.3
Divided pus h- pull s ignal
74
21.4
W obble s ignal
74
21.5
Phas e depth
75
21.6
T r ac k loc ation
75
22
Signals f rom Headers
75 - vi -
22.1
Ref er enc e r ef lec tanc e I t o p
75
22.2
Addr es s Mar k and ID s ignals
76
22.3
Q W M s ignals
76
22.4
T im ing m ean and j itter
77
Sect ion 5 - Charact erist ics of t he recording layer
78
23
M et h o d o f t est in g
78
Envir onm ent
78
23.1
23.2 Ref er enc e Dr ive 23.2.1 O ptic s and m ec hanic s 23.2.2 Read power 23.2.3 Read Channel 23.2.4 T r ac k ing 23.2.5 Signal detec tion f or tes ting purpos es
78 78 78 78 78 78
23.3 W r ite c onditions 23.3.1 W r ite puls e and power wavef or m 23.3.2 W r ite puls e power 23.3.3 W r ite puls e tim ing 23.3.4 W r ite puls e power and puls e tim ing deter m ination
79 79 79 79 79
23.4
Er as e power f or T ype RW m edia
80
23.5
Read power dam age
80
24
Phase Change charact erist ics
80
24.1
Mar k polar ity
80
24.2
Rewr ite c yc les f or T ype RW m edia
80
25
W rite ch aract erist ics
81
25.1
Res olution
81
25.2
Nar row- Band Signal- to- Nois e Ratio (NBSNR)
81
25.3
Cr os s - talk r atio
82
25.4 T im ing m ean 25.4.1 T im ing m ean f or 2T m ar k s and s pac es 25.4.2 T im ing m ean f or n = 3T to 9T , m ar k s and s pac es
82 82 82
25.5 T im ing j itter 25.5.1 T im ing j itter f or 2T m ar k s and s pac es 25.5.2 T im ing j itter f or 3T to 9T m ark s and s pac es
83 83 83
25.6 As ym m etr y 25.6.1 As ym m etr y ( 3T - 2T ) 25.6.2 As ym m etr y ( 9T - 3T )
83 83 83
26
83
26.1
Erase p o w er det ermin at io n f o r T yp e RW med ia Cr os s - Er as e f or T ype RW Media
83 - vii -
Sect io n 6 - Charact erist ics of user dat a
85
27
85
27.1
User Dat a – M et hod of t est ing Envir onm ent
85
27.2 Ref er enc e Dr ive 27.2.1 O ptic s and m ec hanic s 27.2.2 Read power 27.2.3 Read Channel 27.2.4 Mar k quality 27.2.5 Channel bit c loc k 27.2.6 Binar y- to- digital c onver ter s 27.2.7 Er r or c or r ec tion 27.2.8 T r ac k ing
85 85 85 85 85 86 86 86 86
28
86
28.1
M inimum qu alit y of a sect or Headers ID
86
28.2 Us er - wr itten data 28.2.1 Rec or ding f ield 28.2.2 Byte er r ors 28.2.3 T im ing m ean 28.2.4 T im ing j itter 28.2.5 As ym m etr y
86 86 87 87 87 87
28.3
87
29
W obble s ignal Dat a in t erch ange requirement s
87
29.1
T r ac k ing
87
29.2
Us er - wr itten data
87
29.3
Q uality of dis k
87
Annex A ( no rmat iv e) Air cleanliness class 100 000
89
An n ex B ( n o rmat iv e) Ed g e d ist o rt io n t est
91
An n ex C ( n o rmat iv e) Co mp lian ce t est
93
Annex D ( n o rmat iv e) Cart ridge elect ro- st atic discharge t est
97
An n ex E ( n o rmat iv e)
99
T est met h od f or measurin g t h e ad so rb en t f o rce o f t h e h u b
An n ex F ( no rmat iv e) CRC f o r ID f ield s
101
An n ex G ( n o rmat iv e) Dat a f ield scramb ler implemen t at io n
103
- viii -
Ann ex H ( n o rmat iv e) Int erleav e, CRC, ECC, Resync, and Ref erence f or t he Dat a f ield
105
An n ex I ( n o rmat iv e) Driv e Inf o rmat io n Reco rd ( DIR) u sage
111
An n ex J ( n o rmat iv e) Det ermin at io n o f t h e Resyn c an d Ref eren ce p at t ern s
113
Ann ex K ( n o rmat iv e) Specif ic Disk Inf ormat ion
115
Ann ex L ( normat iv e) Read Channel f or measuring analog signals and jit t er
129
An n ex M ( no rmat iv e) T imin g mean an d t imin g jit t er measu ring p rocedu re
131
An n ex N ( n o rmat iv e) Imp lemen t at io n In d ep en d en t M ark Q u alit y Det ermin at io n ( IIM Q D) f o r t h e in t erch an g e o f reco rded med ia
133
An n ex O ( n o rmat iv e) Def in it io n o f t h e w rit e p u lse shap e
135
An n ex P ( n ormat iv e) Asymmet ry measu rin g d ef init io n
137
An n ex Q ( n o rmat iv e) En han ced Select iv e In t er- Symbo l In t erf eren ce Can cellat io n ( ESISIC) algo rithm 139 An n ex R ( n o rmat iv e) Req u irement s f o r in t erch an g e
141
An n ex S ( in f o rmat iv e) O f f ice en v iro n men t
143
An n ex T ( in f o rmat iv e) Deriv at io n o f t h e o p erat in g climat ic en v iro n men t
145
An n ex U ( inf o rmat iv e) T ran sp o rt at io n
151
Ann ex V ( inf ormat iv e) T rack dev iat ion measurement
153
Ann ex W ( inf ormat iv e) M easurement of t he v ert ical biref ringence of t he cov er layer
157
An n ex X ( in f o rmat iv e) Q u ad rat u re W ob b le of f set co n t ro l
159
An n ex Y ( in f o rmat iv e) St art Po sit io n Sh if t ( SPS) imp lemen t at io n
163
Ann ex Z ( in f ormat iv e) Sect or ret irement guidelines
165
An n ex AA ( inf o rmat iv e) G u id elin es f o r t h e u se o f T yp e W O RM O DCs
167
An n ex BB ( in f o rmat iv e) M ed ia t yp e id en t if icat ion in exist in g an d f u t u re st andards
169
- ix -
An n ex CC ( in f o rmat iv e) L aser p o w er calib rat io n f o r ev aluat io n o f med ia p o w er paramet ers
-x-
171
Section 1 - General 1
Scope This Ecma Standard specifies the mechanical, physical, and optical characteristics of a 130 mm optical disk cartridge (ODC) that employs thermo-optical Phase Change effects to enable data interchange between such disks. This Ecma Standard specifies two types, viz. -
Type RW (Rewritable) provides for data to be written read and erased many times over the recording surfaces of the disk.
-
Type WORM (Write Once Read Many) provides for data once written to be read a multiplicity of times. This type shall use a Write Once Read Many times recording material (written marks cannot be erased and attempted modifications of the written marks are detectable). Multisession (incremental write operations) recording may be performed on Type WORM disks.
The disk shall be two-sided with a nominal capacity of 15,0 Gbytes per side and the cartridge (two sides) shall provide a nominal capacity of 30,0 Gbytes. This Ecma Standard specifies -
the conditions for conformance testing and the Reference Drive;
-
the environments in which the cartridges are to be operated and stored;
-
the mechanical, physical and dimensional characteristics of the cartridge so as to provide mechanical interchangeability between data processing systems;
-
the format of the information on the disk, both embossed and user-written, including the physical disposition of the tracks and sectors, the error correction codes, the modulation methods used;
-
the characteristics of the embossed information on the disk;
-
the thermo-optical characteristics of the disk, enabling processing systems to write data onto the disk;
-
the minimum quality of user-written data on the disk, enabling data processing systems to read data from the disk.
This Ecma Standard provides for interchange between optical disk drives. Together with a standard for volume and file structure, it provides for full data interchange between data processing systems.
2 2.1
Conformance Optical disk An ODC shall be in conformance with this Ecma Standard if it meets all mandatory requirements specified therein. A claim of conformance with this Ecma Standard shall specify the Type, RW, WORM, implemented.
2.2
Generating system A claim of conformance with this Ecma Standard shall specify which Type(s) is (are) supported. A system generating an ODC for interchange shall be in conformance with this Ecma Standard if it meets the mandatory requirements of this Ecma Standard for the Type(s) supported.
-1-
2.3
Receiving system A claim of conformance with this Ecma Standard shall specify which Type(s) is (are) supported. A system receiving an ODC for interchange shall be in conformance with this Ecma Standard if it is able to process any recording made on the cartridge according to 2.1 on the Type(s) specified.
2.4
Compatibility statement A claim of conformance with this Ecma Standard shall include a statement listing any other Optical Disk Cartridge Standard supported by the system for which conformance is claimed. This statement shall specify the number of the Standard(s), including, where appropriate, the ODC Type(s), and whether support includes reading only or both reading and writing.
3
Reference The following Standard contains provisions, which through reference in this text, constitute provisions of this Ecma Standard. At the time of publication, the edition indicated was valid. All standards are subjected to revision, and parties to agreements based on this Ecma Standard are encouraged to investigate the possibility of applying the most recent edition of the following Standard. ECMA-287 (1999): Safety of electronic equipment
4
Definitions For the purpose of this Ecma Standard the following definitions apply.
4.1
asymmetry The deviation between the centre levels of signals generated by two distinct repeating mark and space length patterns.
4.2
band An annular area on the disk having a constant clock frequency.
4.3
case The housing for an optical disk that protects the disk and facilitates disk interchange.
4.4
Case Reference Plane A plane defined for each side of the case, to which the dimensions of the case are referred.
4.5
Channel bit The elements by which, after modulation, the binary values ZERO and ONE are represented by marks and spaces on the disk.
4.6
Clamping Zone The annular part of the disk within which the clamping force is applied by the clamping device.
4.7
cover layer A transparent layer of the disk through which the optical beam accesses the recording layer.
4.8
Cyclic Redundancy Code (CRC) A method for detecting errors in data.
4.9
Data field A subdivision of a sector intended for the recording of user data. -2-
4.10
Defect Management A method for handling the defective areas on the disk.
4.11
Disk Reference Plane A plane defined by the perfectly flat annular surface of an ideal spindle onto which the Clamping Zone of the disk is clamped, and which is normal to the axis of rotation.
4.12
entrance surface The surface of the disk onto which the optical beam first impinges.
4.13
Error Correction Code (ECC) An error-detecting code designed to correct certain kinds of errors in data.
4.14
field A subdivision of a sector.
4.15
format The arrangement or layout of information on the disk. The annular area on the disk bearing the format is the Formatted Zone.
4.16
hub The central feature on the disk, which interacts with the spindle of the disk drive to provide radial centring and the clamping force.
4.17
interleaving The process of allocating the physical sequence of units of data so as to render the data more immune to burst errors.
4.18
land and groove A trench-like feature of the disk, applied before the recording of any information, and used to define the track location. The land is located nearer to the entrance surface than the groove with which it is paired to form a Physical Track. Recording is performed on both the land and groove.
4.19
mark A feature of the recording layer which takes the form of a pit, change in the reflectivity, or any other type or form that can be sensed by the optical system. The pattern of marks represents the data on the disk.
4.20
Mirror Area An area in which there is no embossed information, neither preformatted headers or grooves.
4.21
optical disk A disk that will accept and retain information in the form of marks in a recording layer, that can be read with an optical beam.
4.22
optical disk cartridge (ODC) A device consisting of a case containing an optical disk.
4.23
Phase Change A physical effect by which the area of a recording layer irradiated by a laser beam is heated so as to change from an amorphous state to a crystalline state and vice versa.
-3-
4.24
Physical Block Address (PBA) A numbering system of the data sectors defined to constitute a uniquely addressable sector location to the recording system.
4.25
Physical Track One revolution (360°) of adjacent groove-land pair.
4.26
read pow er The optical power, incident at the entrance surface of the disk, used when reading.
4.27
recording layer A layer of the disk on, or in, which data is written during manufacture and/or use. The recording layer may actually consist of a multiple layer stack of different materials or composite materials.
4.28
Recording Track One revolution (360 °) of either a land feature or groove feature of the disk (Land Recording Track or Groove Recording Track) where recording may be performed.
4.29
Reed-Solomon code An error detection and/or correction code which is particularly suited to the correction of errors which occur in bursts or are strongly correlated.
4.30
sector The smallest addressable part of a track in the formatted area of the disk.
4.31
space The area between marks along the track.
4.32
spindle The part of the disk drive which contacts the disk and/or hub.
4.33
substrate A layer of the disk provided for mechanical support of the recording layer.
4.34
track A path which is followed by the focus of the optical beam during exactly one revolution of the disk.
4.35
track pitch The distance between Land Recording Track centrelines and adjacent Groove Recording Track centrelines, measured in the radial direction.
4.36
User Area The area of the disk intended for the recording of user data.
4.37
w obble A periodic radial deviation of the track (groove or land) from the average centreline that is used as a supplemental timing signal.
4.38
w rite-inhibit hole A hole in the case which, when detected by the drive to be open, inhibits write operations.
-4-
4.39
zone An annular area of the disk.
5 5.1
Conventions and notations Representation of numbers A measured value is rounded off to the least significant digit of the corresponding specified value. For instance, it implies that a specified value of 1,26 with a positive tolerance of + 0,01 and a negative tolerance of - 0,02 allows a range of measured values from 1,235 to 1,275. Numbers in decimal notations are represented by the digits 0 to 9. Numbers in hexadecimal notation are represented by the hexadecimal digits 0 to 9 and A to F in parentheses. The setting of bits is denoted by ZERO and ONE. Numbers in binary notations and bit patterns are represented by strings of digits 0 and 1, with the most significant bit shown to the left. Negative values of numbers in binary notation are given as Two’s complement. In each field the data is recorded so that the most significant byte (MSB), identified as Byte 0, is recorded first and the least significant byte (LSB) last. In a field of 8n bits, bit b (8n-1) shall be the most significant bit (msb) and bit b 0 the least significant bit (lsb). Bit b (8n-1) is recorded first. A binary digit which can be set indifferently to ZERO or to ONE is represented by “x”.
5.2
Names The names of entities, e.g. specific tracks, fields, areas, zones, etc. are given a capital initial.
6
Acronyms AM CRC DDS DIR DMA ECC ESISIC ID LBA LSB lsb MSB msb NA NBSNR NRZ ODC PA PBA PDL PLL PSA QWM QWMG QWML
Address Mark Cyclic Redundancy Code Disk Definition Structure Drive Information Record Defect Management Area Error Correction Code Enhanced Selective Inter-Symbol Interference Cancellation Identifier Logical Block Address Least Significant Byte least significant bit Most Significant Byte most significant bit Numerical Aperture Narrow-Band Signal-to-Noise Ratio Non Return to Zero Optical Disk Cartridge Postamble Physical Block Address Primary Defect List Phase Locked Loop Primary Spares Area Quadrature Wobble Marks Quadrature Wobble Marks on Groove Quadrature Wobble Marks on Land
-5-
RESYNC RFO RLL RW SCSI SDI SDL SPS SSA STOB SYNC TA TIA UDO VAP VFO WORM ZCAV
7
Re-Synchronization Read Focus Offset Run-Length Limited (code) Rewritable Small Computer System Interface Specific Disk Information Secondary Defect List Start Position Shift Secondary Spares Area Six Time Oversampled Bi-Phase Synchronization Transition Area Time Interval Analyzer Ultra Density Optical (disk) Verify and Protect Variable Frequency Oscillator Write Once Read Many Zoned Constant Angular Velocity
General description The optical disk cartridge, which is the subject of this Ecma Standard, consists of a case containing an optical disk. The case is a protective enclosure for the disk. It has access windows covered by two shutters. One of the windows is automatically uncovered by the drive when the cartridge is inserted into it. The optical disk is made from two sides that are assembled together. Each side consists of a Phase Change recording layer placed between the substrate and the cover layer. The substrates of each side are bonded together. The optical disk is recordable on both sides. Data can be written onto the disk as marks with Phase Change characteristics variations in the recording layer, using a focused optical beam. Data can be read by the optical beam using the change in reflectivity and diffraction between mark and space in the recording layer. The beam accesses the recording layer through the transparent cover layer of the disk. Part of the disk contains read-only data in the form of pre-embossed pits. This data can be read using the diffraction of the optical beam by the embossed pits.
8
General requirement
8.1 8.1.1
Environments T est env ironment The test environment is the environment where the air immediately surrounding the optical disk cartridge has the following properties: Temperature :
23 °C ± 2 °C
Relative humidity :
45 % to 55 %
Atmospheric pressure :
60 kPa to 106 kPa
Air cleanliness :
Class 100 000 (see Annex A)
No condensation on or in the optical disk cartridge shall occur. Before testing, the optical disk cartridge shall be conditioned to this environment for 48 hours minimum. It is recommended that, before testing, the entrance surface of the disk be cleaned according to the instructions of the manufacturer of the disk. Unless otherwise stated, all tests and measurements shall be made in this test environment. -6-
8.1.2
O p erat ing env ironment This Ecma Standard requires that an optical disk cartridge, which meets all requirements of this Standard in the specified test environment, provides interchange over the specified ranges of environmental parameters in the operating environment. The operating environment is the environment where air immediately surrounding the optical disk cartridge has the following properties: Temperature :
5 °C to 55 °C
Relative humidity :
3 % to 85 %
Absolute humidity :
1 g/m to 30 g/m
Atmospheric pressure :
60 kPa to 106 kPa
Temperature gradient :
10 °C/h max.
3
3
Relative humidity gradient : 10 %/h max. Air cleanliness :
Office environment (see Annex S)
No condensation on or in the optical disk cartridge shall occur. If an optical disk cartridge has been exposed to conditions outside those specified in this clause, it shall be acclimatized in an allowed operating environment for at least 2 hours before use (see also Annex T). 8.1.3
St o rage env ironment The optical disk cartridge without any protective enclosure shall not be stored in an environment outside the range allowed for storage. The storage environment is defined as an environment where the air immediately surrounding the optical disk cartridge has the following properties: Temperature :
-10 °C to 55 °C
Relative humidity :
3 % to 90 %
Absolute humidity :
1 g/m to 30 g/m
Atmospheric pressure :
60 kPa to 106 kPa
Temperature gradient :
15 °C/h max.
3
3
Relative humidity gradient : 10 %/h max. Air cleanliness :
Office environment (see Annex S)
No condensation on or in the optical disk cartridge shall occur. 8.1.4
8.2
T ransport at ion This Ecma Standard does not specify requirements for transportation. Guidance for transportation is given in Annex U.
Temperature shock The optical disk cartridge shall withstand a temperature shock of up to 20 °C when inserted into, or removed from, the drive.
8.3
Safety requirements The cartridge shall satisfy the safety requirements of Standard ECMA-287, when used in the intended manner or in any foreseeable use in an information processing system.
8.4
Flammability The cartridge and its components shall be made from materials that comply with the flammability class for HB materials, or better, as specified in Standard ECMA-287.
-7-
9
Reference Drive The Reference Drive is a drive several critical components of which have well defined properties and which is used to test the read, write, and erase parameters of the disk for conformance to this Ecma Standard. This section gives an outline of all components; components critical for tests in specific sections are specified in those sections.
9.1
Optical system The basic set-up of the optical system of the Reference Drive used for measuring the write, read and erase parameters is shown in figure 1. Different components and locations of components are permitted, provided that the performance remains the same as that of the set-up in figure 1. The optical system shall be such that the detected light reflected from the entrance surface of the disk is minimized so as not to influence the accuracy of the measurements.
A
Laser diode
F
Objective lens
B
Collimator lens
G
Optical disk
C
Optional shaping prism
H
Split photodetector
D
Polarizing beamsplitter
I1, I2
Outputs currents from the split photodetector
E
Quarter-wave plate
K1, K2
d.c.-coupled amplifiers
Figure 1 – Optical system of the Reference Drive
The combination of the polarizing beamsplitter D and quarter-wave plate E separates the incident optical beam and the beam reflected from the optical disk G. The polarizing beamsplitter D shall have a p-s intensity reflectance ratio of at least 90.
-8-
9.2
Optical beam The focused optical beam used for writing, reading and erasing data shall have the following properties: Wavelength (O)
405 nm to 410 nm
Polarization
Circular
Numerical aperture
0,70 ± 0,01
Light intensity at the rim of the pupil of the objective lens
50 % to 60 % of the maximum intensity level
Wave front aberration after passing through an ideal cover layer of the disk (Thickness: 0,1 mm and index of refraction: 1,55) Relative intensity noise (RIN) 10 log [(a.c. light power density/Hz)/d.c. light power]
9.3
0,033 O rms max. - 130 dB/Hz max.
Read Channel The Read Channel shall be used for reading embossed and written marks, using the changes in diffraction and reflectivity produced by the marks. The Read Channel shall detect the total amount of light in the exit pupil of the objective lens. The amplifier K 1 after the photodetector shall be d.c-coupled and have a flat response within 1 dB from d.c. to 60 MHz.
9.4
Tracking The method of generating the axial tracking error is not specified for the Reference Drive. The radial tracking error is generated in the Radial Tracking Channel from the output currents of a split photodiode detector, the division of which runs parallel to the image of the tracks on the diode (see figure 1). The radial tracking error signal relates to the difference in the amount of light in the two halves of the exit pupil of the objective lens. The amplifier K 2 after the photodetector shall be d.c.-coupled with the bandwidth characteristics specified in clause 21. The requirements for the accuracy with which the focus of the optical beam must follow the tracks is specified in 20.2.4.
9.5
Rotation of the disk The spindle shall position the disk as specified in 12.4. It shall rotate the disk at 32,5 Hz ± 0,25 % for Type RW and 35,0 Hz ± 0,25 % for Type WORM. The direction of rotation of the disk side being tested shall be counter-clockwise when viewed from the objective lens.
-9-
Section 2 - Mechanical and physical characteristics 10
Dimensional and physical characteristics of the case
10.1
General description of the case The case (see figure 2) is a rigid protective container of rectangular shape. It has windows on both side A and side B to allow the spindle of the drive to clamp the disk by its hub and to allow the head to access the disk. The A- or B-shutter uncovers the window upon insertion into the drive, and automatically covers it upon removal from the drive. The case has media identification, write-inhibit, mis-insertion features, detent for autoloading, gripper slots for an autochanger, label areas, and side identification inscriptions.
10.2
Relationship of Sides A and B The features essential for physical interchangeability are represented in figure 2. When Side A of the cartridge faces upwards, Side A of the disk faces downwards. Sides A and B of the case are identical as far as the features given here are concerned. The description is given for one side only. References to Sides A and B can be changed to B or A respectively.
10.3
Reference axes and case reference planes There is a Case Reference Plane P for each side of the case. Each Case Reference Plane P contains two orthogonal axes X and Y to which the dimensions of the case are referred. The intersection of the X and Y axes defines the centre of the location hole. The X axis extends through the centre of the alignment hole.
10.4
Case draw ings The case is represented schematically by the following drawings. Figure 2 shows a composite drawing of Side A of the case in isometric form, with the major features identified from Side A. Figure 3 shows the envelope of the case with respect to a location hole at the intersection of the X and Y axes of Case Reference Plane P. Figure 4 shows the surfaces S1, S2, S3 and S4 which establish the Case Reference Plane P. Figure 4a shows the details of surface S3. Figure 5 shows the details of the insertion slot and detent. Figure 6 shows the gripper slots, used for automatic handling. Figure 7 shows the write-inhibit holes. Figure 8 shows the media identification sensor holes. Figure 9 shows the head and motor window. Figure 10 shows the shutter opening features. Figures 11a and 11b show the user label areas.
10.5 10.5.1
Dimensions of the case O v erall dimensions The total length of the case (see figure 3) shall be L 1 = 153,0 mm ± 0,4 mm The distance from the top of the case to the reference axis X shall be L 2 = 127,0 mm ± 0,3 mm
- 10 -
The distance from the bottom of the case to the reference axis X shall be L 3 = 26,0 mm ± 0,3 mm The total width of the case shall be + 0,0 mm
L 4 = 135,0 mm
- 0,6 mm
The distance from the left-hand side of the cartridge to the reference axis Y shall be + 0,0 mm
L 5 = 128,5 mm
- 0,5 mm
The distance from the right-hand side of the cartridge to the reference axis Y shall be L 6 = 6,5 mm ± 0,2 mm The width shall be reduced on the top by the radius R1 = L4 originating from a point defined by L 5 and L 7 = 101,0 mm ± 0,3 mm The two corners of the top shall be rounded with a radius R 2 = 1,5 mm ± 0,5 mm and the two corners at the bottom with a radius R 3 = 3,0 mm ± 1,0 mm The thickness of the case shall be L 8 = 11,00 mm ± 0,30 mm The eight long edges of the case shall be rounded with a radius R 4 = 1,0 mm max. 10.5.2
Locat ion hole The centre of the location hole (see figure 3) shall coincide with the intersection of the reference axes X and Y. It shall have a square form with a side length of + 0,00 mm
L 9 = 4,10 mm
- 0,06 mm
held to a depth of L 10 = 2,35 mm (i.e. typical wall thickness) after which a cavity extends through to the alignment hole on the opposite side of the case. The lead-in edges shall be rounded with a radius R 5 = 0,5 mm max. 10.5.3
Alignment hole The centre of the alignment hole (see figure 3) shall lie on reference axis X at a distance of L 11 = 122,0 mm ± 0,2 mm from the reference axis Y.
- 11 -
The dimensions of the hole shall be + 0,00 mm
L 12 = 4,10 mm
- 0,06 mm
and + 0,2 mm
L 13 = 5,0 mm
- 0,0 mm
held to a depth of L 10 , after which a cavity extends through to the location hole on the opposite side of the case. The lead-in edges shall be rounded with radius R 5 . 10.5.4
Surf aces on Case Ref erence Planes P The Case Reference Plane P (see figures 4 and 4a) for a side of the case shall contain four surfaces (S1, S2, S3 and S4) on that side of the case, specified as follows: Two circular surfaces S1 and S2. Surface S1 shall be a circular area centred around the square location hole and have a diameter of D 1 = 9,0 mm min. Surface S2 shall be a circular area centred around the rectangular alignment hole and have a diameter of D 2 = 9,0 mm min. Two elongated surfaces S3 and S4, that follow the contour of the cartridge and shutter edges. Surfaces S3 and S4 are shaped symmetrically. Surface S3 shall be defined by two circular sections with radii R 6 = 1,5 mm ± 0,1 mm with an origin given by L 14 = 4,0 mm ± 0,1 mm L 15 = 86,0 mm ± 0,3 mm and R 7 = 1,5 mm ± 0,1 mm with an origin given by L 16 = 1,9 mm ± 0,1 mm L 17 = 124,5 mm ± 0,3 mm The arc with radius R 7 shall continue on the right hand side with radius + 0,2 mm
R 8 = 134,0 mm
- 0,7 mm
which is a dimension resulting from L 5 + L 14 + R 6 with an origin given by L 5 and L 7 . A straight, vertical line shall smoothly join the arc of R 6 to the arc of R 8 . The left-hand side of S3 shall be bounded by radius R 9 = 4,5 mm ± 0,3 mm which is a dimension resulting from L 18 + L 14 - R 6 with an origin given by L 18 = 2,0 mm ± 0,1 mm - 12 -
L 19 = 115,5 mm ± 0,3 mm The left-hand side of the boundary shall be closed by two straight lines. The first one shall smoothly join the arc of R 6 to the arc of R 9 . The second one shall run from the left-hand tangent of R 7 to its intersection with R 9 . 10.5.5
In sert io n slo t s an d det en t f eat u res The case shall have two symmetrical insertion slots with embedded detent features (see figure 5). The slots shall have a length of L 20 = 35,0 mm ± 0,3 mm a width of + 0,3 mm
L 21 = 6,0 mm
- 0,0 mm
and a depth of L 22 = 3,0 mm ± 0,1 mm located L 23 = 2,5 mm ± 0,2 mm from Case Reference Plane P. The slots shall have a lead-in chamfer given by L 24 = 0,5 mm max. L 25 = 5,0 mm max. The detent notch shall be a semi-circle of radius R 10 = 3,0 mm ± 0,2 mm with the origin given by L 26 = 13,0 mm ± 0,3 mm L 27 = 2,0 mm ± 0,1 mm L 28 = 114,0 mm ± 0,3 mm The dimensions L 2 , L 26 , and L 28 are interrelated, their values shall be such so that they are all three within specification. 10.5.6
G ripper slot s The case shall have two symmetrical gripper slots (see figure 6) with a depth of L 29 = 5,0 mm ± 0,3 mm from the edge of the case and a width of L 30 = 6,0 mm ± 0,3 mm The upper edge of a slot shall be L 31 = 12,0 mm ± 0,3 mm above the bottom of the case.
10.5.7
W rit e- inhibit holes Sides A and B shall each have a write-inhibit hole (see figure 7). The case shall include a device for opening and closing each hole. The hole at the left-hand side of Side A of the case, is the write-inhibit hole for Side A of the disk. The protected side of the disk shall be made clear by inscriptions on the case or by the fact that the device for Side A of the disk can only be operated from Side A of the case.
- 13 -
When writing and erasing on Side A of the disk is not allowed, the write-inhibit hole shall be open all through the case. It shall have a diameter D 3 = 4,0 mm min. Its centre shall be specified by L 32 = 8,0 mm ± 0,2 mm L 33 = 111,0 mm ± 0,3 mm on Side A of the case. When writing is allowed on Side A of the disk, the write-inhibit hole shall be closed on Side A of the case, at a depth of typically L 10 , i.e. the wall thickness of the case. In this state, the opposite side of the same hole, at Side B of the case, shall be closed and not recessed from the Case Reference Plane P of Side B of the case by more than L 34 = 0,3 mm max. The opposite side of the write-inhibit hole for protecting Side B of the disk shall have a diameter D 3 . Its centre shall be specified by L 32 and L 35 = 11,0 mm ± 0,2 mm on Side A of the case. 10.5.8
M edia ident if icat ion sensor ho les There shall be two sets of two media sensor holes (see figure 8). The holes shall extend through the case, and have a diameter of + 0,3 mm
D 4 = 4,0 mm
- 0,0 mm
the positions of their centres shall be specified by L 33 , L 35 and L 36 = 19,5 mm ± 0,2 mm L 37 = 17,0 mm ± 0,2 mm L 38 = 105,0 mm ± 0,3 mm A hole is deemed to be open when there is no obstruction in this hole over a diameter D 4 all through the case. A hole is deemed to be closed, when the hole is closed on both Side A and Side B of the case. The closure shall be recessed from Case Reference plane P by L 39 = 0,3 mm max. The holes closest to the long edges of the case are numbered 1. The other holes are numbered 2. The meaning of the status (closed, open) of each hole shall be as in table 1. T able 1 – Media identif ic ation s ens or holes Sensor Hole No.
Indication
Closed
Open
1
Media Type
WORM
RW
2
Future use*
Yes
No
* This hole shall be closed in cartridges conforming to this Ecma Standard.
- 14 -
10.5.9
Head and mo t o r w in do w The case shall have a window on each side to enable the optical head and the motor spindle to access the disk (see figure 9). The dimensions are referenced to a centreline, located at a distance of L 40 = 61,0 mm ± 0,2 mm to the left of reference axis Y. The width of the head access shall be defined by L 41 = 17,50 mm min. L 42 = 17,50 mm min. and its height shall extend to L 43 = 118,2 mm min. The two inside corners shall be rounded with a radius of R 11 = 3,0 mm max. The motor spindle access shall have a diameter of D 5 = 35,0 mm min. and its centre shall be defined by L 40 and L 44 = 43,0 mm ± 0,2 mm
10.5.10 Shu t t ers The case shall have two spring-loaded, unidirectional shutters (see figure 10), designed to completely cover the head and motor windows when closed. A shutter movement of 36,5 mm shall be sufficient to ensure that the head and motor window is opened to the minimum size specified in 10.5.9. The shutter shall be free to slide in a recessed area of the case in such a way as to ensure that the overall thickness of the case and shutter shall not exceed L 8 . The top surface of the shutters shall be at L 45 = 126,7 mm ± 0,3 mm 10.5.11 Slo t s f o r sh u t t er o p en er Both Side A and Side B shutter shall have only one slot (see figure 10) in which the shutter opener of the drive can engage to open the shutter. The slot shall be dimensioned as follows: When the shutter is closed, the centre of the slot used to push the shutter open shall be located at a distance of L 46 = 55,0 mm ± 0,5 mm from reference axis Y on either side the case. The length of the slot shall be L 47 = 7,0 mm ± 0,1 mm The depth of the slot shall be L 48 = 3,5 mm ± 0,5 mm The width of each slot from the Case Reference Plane P of Side A and B of the case shall be + 0,5 mm
L 49 = 4,5 mm
- 0,0 mm
- 15 -
10.5.12 Slo t s t o p rev en t in sert io n int o a M O - driv e The case shall have two non-moveable slots (see figure 10) designed to prevent from insertion into MO-drives using cartridges conforming to Standard ECMA-322 (or into drives using similar cartridge designs as specified in ECMA-280, ECMA-238, ECMA-195, ECMA-184, ECMA-183, and ECMA-153). These two non-moveable slots have no function when the case is inserted into a drive designed to receive cartridges conforming to this Ecma Standard. The edge designed to engage with the shutter opening arm of such MO-drives and so prevent further insertion, shall be located at a distance of L 50 = 36,5 mm ± 0,2 mm from reference axis Y on either side the case. The length of the slot shall be L 51 = 4,5 mm ± 0,5 mm and the angle of the lead-out ramp shall be A 1 = 60,0° ± 1,0° The depth of the slot shall be L 52 = 4,0 mm ± 0,5 mm With both side A and side B shutter closed the width of each slot shall be the full width of the case L 8 . 10.5.13 User label areas The case shall have the following minimum areas for user labels (see figure 11a): on Side A and Side B:
33,5 mm x 70,5 mm
on the bottom side:
7,0 mm x 115,0 mm
These areas shall be recessed by 0,2 mm min. Their positions are specified by the following dimensions and relations between dimensions. L 53 = 29,0 mm min. L 54 – L 53 = 70,5 mm min. L 56 – L 55 = 33,5 mm min. L 8 – L 59 – L 60 = 7,0 mm min. L 4 – L 57 – L 58 = 115,0 mm min.
10.6
Mechanical characteristics All requirements of this clause shall be met in the operating environment.
10.6.1
M aterials The case shall be constructed from any suitable materials such that it meets the requirements of this Ecma Standard.
10.6.2
M ass The mass of the case without the optical disk shall not exceed 150 g.
10.6.3
Ed g e d ist o rt io n The cartridge shall meet the requirement of the edge distortion test defined in Annex B.
10.6.4
Comp liance The cartridge shall meet the requirement of the compliance (flexibility) test defined in Annex C. The requirement guarantees that a cartridge can be constrained in the proper plane of operation within the drive.
- 16 -
10.6.5
10.7
Sh u t t er o p en in g f o rce The spring force on the shutter shall be such that the force required to open the shutter does not exceed 2 N. It shall be sufficiently strong to close a free-sliding shutter, irrespective of the orientation of the case.
Drop test The optical disk cartridge shall withstand dropping on each surface and on each corner from a height of 1,2 m onto a concrete floor covered with a vinyl layer 2 mm thick. The cartridge shall withstand all such impacts without any functional failure. The write-inhibit switches shall not move to change the state (open or closed) of the write-inhibit holes during the drop test.
10.8
Electro-static discharge test The optical disk cartridge shall meet the electro-static discharge requirements specified in Annex D.
- 17 -
Side B shutter (shown in open position)
Slot for the shutter opener (figure 10)
Surface S4 (figure 4)
Side A shutter (shown in closed position) Case Side A
Disk Side B
Insertion direction Insertion slot and detent (figure 5)
Hub (figure 12)
Aligment hole (figure 3) Surface S3 (figures 4, 4a)
Surface S2 (figure 4) Gripper slot (figure 6)
Head and motor window (figure 9)
Write-inhibit hole for side A (figure 7)
User label area (figure 11) Media sensor holes (figure 8)
Location hole (figure 3) Surface S1 (figure 4) Media sensor holes (figure 8)
Gripper slot (figure 6)
Write-inhibit hole for side B (figure 7)
03-0022-A
Figure 2 – Case
- 18 -
R2
R1
Section A - A ( 2 : 1)
L1 0 R5
L2
R5
L1 0
L7
L1
L9
X
L3
A
R3
L9
A
Location hole L6
L11 L5 L4
Y
L1 2
R4
P
L1 3
Alignment hole L8 03-0001-A
Figure 3 – Overall dimensions and reference axes
- 19 -
See figure 4a
R8
S3 S4
L 17
L7
L1 9 L 15
X
S2
S1
D2
D1 R3
L5
L14 L 18 Y
03-0002-A
Figure 4 – Surfaces S1, S2, S3 and S4 of the Case Reference Plane P
- 20 -
L1 6 R7
R8
R9
L1 7 S3
R6
L7 L5
L1 4
L18
Y
03-0003-A
Figure 4a – Details of surface S3
- 21 -
L1 9
L1 5
L2 4
L2 5
R1 0 L2 7
L2 2
Y
L8
L2 3
L2 1
L2 6
L2 0
L28
X
03-0004-A
Figure 5 – Insertion slots and detents
- 22 -
X
L 30
Y
L2 9
L3 1
03-0005-A
Figure 6 – Gripper slots
- 23 -
X
L3 2
B
B
D3
L3 5 L
L 10
03-0006-A
33
Section B-B
Write-inhibited
Write-enabled
L 10
L34
L3 4
Figure 7 – Write-inhibit holes
- 24 -
Y
X
L3 6
C
C
L3 5 L3 7
4 D4 L 38
Y
L33
Closed
Section C-C
L3 9
Closure plugs
03-0007-A
L3 9 Figure 8 – Media identification sensor holes
- 25 -
Opened Plugs punched-out
L4 1
L4 2
R
11
L4 3
L4 4
X
D5
L 40
Y
03-0008-A
Figure 9 – Head and motor window
- 26 -
Y
X
L4 5
A1
A1
L51 L5 0
L5 1 L5 2
L5 0
L4 8
L4 6
P
L4 7
L4 9
L4 9
L4 7
L
03-0009-A
46
Figure 10 – Shutter opening features
- 27 -
L
X
L 53
L5 5
Y
L5 6
03-0010-A
Figure 11a – User label area (Identical on Side A and Side B)
L4
L5 8
L5 7
User label area
L5 9 L6 0
03-0011-A
Figure 11b – User label area on bottom surface
- 28 -
L8
54
11
Dimensional, mechanical, and physical characteristics of the disk
11.1
General description of the disk The disk shall consist of two sides. Each disk side shall consist of a circular substrate with a hub on one face. The substrate is coated with a recording layer on the same disk face as the hub. The recording layer is protected from environmental influences by a protective 100 Vm thick cover layer. The cover layer shall be transparent to allow an optical beam to focus on the recording layer (see 11.5). The two disk sides shall be assembled with the cover layer facing outwards. The circular hubs are in the centre of the disk. They interact with the spindle of the drive, and provide the radial centring and the clamping force.
11.2
Reference axis and plane of the disk Some dimensions of the hub are referred to a Disk Reference Plane D (see figure 12). The Disk Reference Plane D is different from Case Reference Plane P that is described in 10.3. Plane D is defined by the perfectly flat annular surface of an ideal spindle onto which the Clamping Zone of the disk is clamped, and which is normal to the axis of rotation of this spindle. The reference axis A of the disk passes through the centre of the centre hole of the hub, and is normal to Disk Reference Plane D. The recording layer is nominally located on Disk Reference Plane D.
11.3
Dimensions of the disk The dimensions of the disk shall be measured in the test environment. The dimensions of the disk in an operating environment can be estimated from the dimensions specified in this clause. The outer diameter of the disk shall be 130,0 mm nominal. The tolerance is determined by the movement of the disk inside the case allowed by 12.3 and 12.4. The total thickness of the disk outside the hub area shall be 2,40 mm min. and 2,80 mm max. The Clamping Zone is the area on the disk where the clamping mechanism of the optical drive grips the disk and is defined by D 6 and D 7 . The clearance zone extending from the outer diameter of the Clamping Zone (D 6 ) to the inner diameter of the reflective zone (see clause 17) shall be excluded from the total thickness requirement; however there shall be no projection from the Disk Reference Plane D in the direction of the optical system of more than 0,2 mm in this zone.
11.3.1
Hu b dimensions The outer diameter of the hub (see figure 12) shall be + 0,0 mm
D 8 = 25,0 mm
- 0,2 mm
The height of the hub shall be + 0,0 mm
h 1 = 2,2 mm
- 0,2 mm
The diameter of the centre hole of the hub shall be + 0,012 mm
D 9 = 4,004 mm
- 0,000 mm
- 29 -
The height of the top of the centring hole at diameter D 9 , measured above the Disk Reference Plane D, shall be h 2 = 1,9 mm min. The centring length at diameter D 9 shall be h 3 = 0,5 mm min. The hole shall have a diameter larger than, or equal to, D 9 between the centring length and the Disk Reference Plane D. There shall be a radius at the rim of the hub at diameter D 9 with height h 4 = 0,2 mm ± 0,1 mm At the two surfaces which it intersects, the radius shall be blended to prevent offsets or sharp ridges. The height of the chamfer at the rim of the hub at diameter D 8 shall be + 0,2 mm
h 5 = 0,4 mm
- 0,2 mm
The angle of the chamfer shall be 45°, or a corresponding full radius shall be used. The outer diameter of the magnetizable ring shall be D 10 = 19,0 mm min. The inner diameter of the magnetizable ring shall be D 11 = 8,0 mm max. The thickness of the magnetizable material shall be h 6 = 0,5 mm min. The position of the top of the magnetizable ring relative to the Disk Reference Plane D shall be + 0,0 mm
h 7 = 2,2 mm
- 0,1 mm
The outer diameter of the Clamping Zone shall be D 6 = 35,0 mm min. The inner diameter of the zone shall be D 7 = 27,0 mm max. 11.3.2
Cov er layer dimensions The inner diameter of the cover layer (see figure 12) shall be D 12 = 36,0 ± 1,0 mm The outer diameter of the cover layer shall extend beyond the start of the Formatted Zone as described in clause 17.
- 30 -
D
12
D6
D7 D8 D 10
D11
h4
D9
D
h5
Substrate h3
h2
h7
Clamping Zone Cover layer
h6
h1
Clamping Zone
Cover layer
03-0012-A
Figure 12 – Hub Dimensions
- 31 -
11.4
Mechanical characteristics All requirements in this clause must be met in the operating environment.
11.4.1
M aterial The disk shall be made from any suitable materials such that it meets the requirements of this Ecma Standard. The only material properties specified by this Ecma Standard are the magnetic properties of the magnetizable ring in the hub (see 11.3.1) and the optical properties of the cover layer in the Formatted Zone (see 11.5).
11.4.2
M ass The mass of the disk shall not exceed 60 g.
11.4.3
M oment of inert ia 2
The moment of inertia of the disk relative to axis A shall not exceed 0,13 g m . 11.4.4
Imbalance The imbalance of the disk relative to axis A shall not exceed 0,01g m.
11.4.5
Axial def lect ion The axial deflection of the disk is measured as the axial deviation of the recording layer. Thus it comprises the tolerances on the thickness of the cover layer, on its index of refraction, and the deviation of the entrance surface from the Disk Reference Plane D. The deviation of any point of the recording layer from its nominal position, in a direction normal to the Disk Reference Plane D, shall not exceed 0,13 mm in the Formatted Zone for rotational frequencies of the disk as specified in 9.5. The deviation shall be measured by the optical system defined in 9.1.
11.4.6
Axial accelerat ion The maximum allowed axial error e max (see Annex V) shall not exceed 0,3 µm, measured using the Reference Servo for axial tracking of the recording layer. The rotational frequency of the disk shall be as specified in 9.5. The stationary part of the motor is assumed to be motionless (no external disturbances). The measurement shall be made using a servo with the transfer function
H s (i7 ) =
X0 1 × 3 i7
where 7 = 2Yf, X 0 /2Y = 1 700 Hz, i =
2
3i7 X0 × i7 1+ 3X 0 1+
-1
or any other servo with 1 + H within the 20 % of 1 + Hs in the bandwidth of 20 Hz to 2 150 kHz. Thus, the disk shall not require an acceleration of more than 11,4 m/s at low frequencies from the servo motor of the Reference Servo. 11.4.7
Radial runout The radial runout of the tracks in the recording layer in the Formatted Zone is measured as seen by the optical head of the Reference Drive. Thus it includes the distance between the axis of rotation of the spindle and reference axis A, the tolerances on the dimensions between axis A and the location of the track, and effects of non-uniformities in the index of refraction of the cover layer.
The radial runout is the difference between the maximum and the minimum distance of any track from the axis of rotation, measured along a fixed radial line over one physical track of the disk. The radial runout shall not exceed 50 µm as measured by the optical system under conditions of a hub mounted on a perfect sized test fixture shaft, for rotational frequencies of the disk as specified in 9.5.
- 32 -
11.4.8
Radial accelerat ion The maximum allowed radial error e max (see Annex V) shall not exceed 0,04 µm, measured using the Reference Servo for radial tracking of the tracks. The rotational frequency of the disk shall be as specified in 9.5. The stationary part of the motor is assumed to be motionless (no external disturbances). The measurement shall be made using a servo with the transfer function
H s (i7 ) =
where 7 = 2Yf, X 0 /2Y = 2 540 Hz, i =
X0 1 × 3 i7
2
3i7 X0 × i7 1+ 3X 0 1+
-1
or any other servo with 1 + H within the 20 % of 1 + Hs in the bandwidth of 20 Hz to 2 150 kHz. Thus, the disk shall not require an acceleration of more than 3,4 m/s at low frequencies from the servo motor of the Reference Servo. 11.4.9
T ilt The tilt angle, defined as the angle which the normal to the entrance surface, averaged over a circular area of 1 mm diameter, makes with the normal to the Disk Reference Plane D, shall not exceed 2,8 mrad in the Formatted Zone.
11.4.10 Axial damping
The vibration of the disk clamped to a spindle with a clamping force of 8 N ± 1 N shall have a first rotationally symmetric resonance frequency mode (umbrella mode) between 200 Hz and 250 Hz with a resonance peaking, measured at disk radius 61 mm ± 1 mm, smaller than 21 dB.
11.5 11.5.1
Optical characteristics In dex of ref ract ion
The index of refraction of the cover layer within the Formatted Zone shall be 1,55 ± 0,10. 11.5.2
T h ickness The thickness of the cover layer shall be determined by its index of refraction as specified in figure 13.
Figure 13 – Cover layer thickness as a function of the index of refraction - 33 -
11.5.3
Birefringence The birefringence value of the cover layer shall be contained as follows: N p – N z Z 500 x 10
-6
where N p is the index of refraction along any direction in the plane of the disk and N z is the index of refraction normal to the plane of the disk (see Annex W). 11.5.4 Ref lectance 11.5.4.1 G eneral The reflectance R is the value of the reflectance in a Recording Track of the User Zone, measured through the cover layer and does not include the reflectance of the entrance surface. The nominal value R, of the reflectance, shall be specified by the manufacturer in byte 39 of the SDI sectors (see 17.4.4). 11.5.4.2 M easured v alue The measured value R m of the reflectance shall be measured under the conditions of 9.2. Measurements shall be made in the User Zone in any Recording Track. 11.5.4.3 Requirement The value of reflectance prior to writing at the standard wavelength specified in 9.2 shall lie within the range 16,5% to 25,0 % for Type RW disks and within the range 15,5% to 20,5% for Type WORM disks. The value of reflectance following writing at the standard wavelength specified in 9.2 shall lie within the range 11,5 % to 19,5% for Type RW disks and within the range 7,5 % to 13,0 % for Type WORM disks. At any point in the User Zone, prior to writing or following writing on Type RW or Type WORM disks, the measured reflectance R m shall meet the following requirement: R (1 – 0,22)
(R m max + R m min ) / 2
R (1 + 0,22)
where R m max and R m min are the maximum and minimum values of the measured reflectance in the User Zone. This requirement specifies the acceptable range for R m , for all disks within the same value R. Additionally, the variation of R m within one revolution shall meet the requirement: (R m max – R m min ) / (R m max + R m min )
12 12.1
0,10
Interface between cartridge and drive Clamping method When the cartridge is inserted into the drive, the shutter of the case is opened and the drive spindle engages the disk. The disk is held against the spindle by an axial clamping force, provided by the magnetizable material in the hub and the magnets in the spindle. The radial positioning of the disk is provided by the centring of the axis of the spindle in the centre hole of the hub. A turntable of the spindle shall support the disk in its Clamping Zone, determining the axial position of the disk in the case.
12.2
Clamping force The clamping force exerted by the spindle shall be less than 14 N. The adsorbent force measured by the test device specified in Annex E shall be in the range of 8,0 N to 12,0 N.
- 34 -
12.3
Capture cylinder The capture cylinder (see figure 14) is defined as the volume in which the spindle can expect the centre of the hole of the hub to be at the maximum height of the hub, just prior to capture. The size of the cylinder limits the allowable play of the disk inside its cavity in the case. This cylinder is referred to perfectly located and perfectly sized alignment and location pins in the drive, and includes tolerances of dimensions of the case and the disk between the pins mentioned and the centre of the hub. The bottom of the cylinder is parallel to the Case Reference Plane P, and shall be located at a distance of L 61 = 0,5 mm min. above the Case Reference Plane P of Side B of the case when Side A of the disk is to be used. The top of the cylinder shall be located at a distance of L 62 = 4,3 mm max. above the same Case Reference Plane P, i.e. that of Side B. The diameter of the cylinder shall be D 13 = 3,0 mm max. Its centre shall be defined by the nominal values of L 40 and L 44 (see 10.5.9).
12.4
Disk position in operating condition When the disk is in the operating condition (see figure 14) within the drive, the position of the active recording layer shall be L 63 = 4,15 mm ± 0,15 mm above the Case Reference Plane P of that side of the case that faces the optical system. Moreover, the torque to be exerted on the disk in order to maintain a rotational frequency of 35 Hz shall not exceed 0,01 N . m, when the axis of rotation is within a circle of diameter D 14 = 0,2 mm max. and a centre given by the nominal values of L 40 and L 44 (see 10.5.9).
- 35 -
D1 3
D
14
X
L4 0
Y
L6 2
L6 1
L
P
03-0013-A
Figure 14 – Capture cylinder
- 36 -
63
L4 4
Section 3 - Format of information 13 13.1
Track and Header geometry Track and Header shape The Formatted Zone shall contain tracks consisting of grooves or land, intended for the continuous servo method (see figure 15). Both grooves and lands form continuous spirals except for Preformatted Header areas, where embossed marks are formed in non-grooved areas. A groove is a trench-like feature, the bottom of which is located farther from the entrance surface than the land. Within each 360° adjacent groove-land pair defined as a Physical Track, there are two Recording Tracks, one is located on the centreline of the groove (Groove Recording Track), and the other is located on the centreline of the land (Land Recording Track). The Headers IDL0, IDL1, and IDL2 are aligned with the centreline of the Land Recording Track, and Headers IDG0, IDG1, and IDG2 are aligned with the centreline of the Groove Recording Track. The QWM fields, QWML, QWMG, follow IDL0, aligned to the centreline of the Land Recording Track, and IDG0, aligned to the centreline of the Groove Recording Track. The shape of the groove and land shall be determined by the requirements in clause 21. DISK OUTER QWML Land
IDL0
Groove Land
IDL1 IDG0
IDL0
Groove
IDG1
B
A A
IDG2
IDG1
IDG2
DISK INNER Figure 15a – Track and Header geometry ID Fields DISK OUTER Zone A ZONE BOUNDARY Zone B DISK INNER
Figure 15b – Track details at zone boundary Figure 15 – Groove and Land Recording Track geometry
- 37 -
Groove Land
IDL2 IDG1
Groove Land
IDL2
IDL1 IDG0
Land
IDL2
IDL1 IDG0
IDL0
A
B
Groove Land
QWMG
A
IDG2
Groove
13.2
Wobble groove The groove shall be continuous between Preformatted Header regions, except for the Mirror Area defined in 13.3. The groove shall have a square wave shaped wobble with a period of 240 Channel bits. The frequency of the wobble shall be constant in each band. The wobble shall complete 502,117 cycles between Preformatted Headers for Type RW media. The wobble shall complete 499,117 cycles between Preformatted Headers for Type WORM media. The wobble groove square wave shall begin immediately following the end of the IDG2 field and shall repeat until the start of the next IDL0 field. The displacement of the first half period of the square wave (first 120 Channel bits after IDG2, see figure 16) shall be in the direction of the disc outer. The wobble characteristics shall comply with the specifications of 21.5. This will correspond to a peak-to-peak displacement of approximately 24 nm. The Groove Recording Track centreline shall be defined as the point in the radial direction at which the displacement of the wobble toward the inner diameter and outer diameter of the disk are equal. The Land Recording Track centreline shall be defined as the midpoint in the radial direction between the two adjacent Groove Recording Track centrelines. The relative radial position of grooves, lands and Preformatted Header elements is illustrated on figure 16.
13.3
Mirror Area The Mirror Area, included for media reflectivity test measurements, shall exist only in specific locations of the disk (see 14.3). The Mirror Area shall be an interruption in the groove immediately following the IDG2 field (see figure 17). The length of the Mirror Area shall be 240 Channel bits.
13.4
Direction of spiral The track shall spiral inward from the outer diameter to the inner diameter, clockwise as viewed from the entrance surface.
13.5
Track pitch The track pitch is the distance between adjacent Land Recording Track centrelines and Groove Recording Track centrelines, measured in a radial direction. The track pitch for Type RW media shall be 0,400 Vm ± 0,02 Vm. The width of a group of bands corresponding to 44 375 Physical Tracks (88 750 Recording Tracks) shall be 35,50 mm ± 0,10 mm. The track pitch for Type WORM media shall be 0,370 Vm ± 0,02 Vm. The width of a group of bands corresponding to 47 972 Physical Tracks (95 944 Recording Tracks) shall be 35,50 mm ± 0,10 mm.
13.6
Physical Track number Track numbers used in this Ecma Standard refer to Physical Tracks, i.e. to land and groove track recording pairs. Physical Track 0 shall begin on the land of the first Physical Track containing Preformatted Headers at the outer diameter of the disk. The track numbers of Physical Tracks located at radii smaller than Physical Track 0 shall be increased by 1 for each Physical Track.
- 38 -
DISK OUTER Land N
IDL0+ QWML
IDL1
IDL2
Centreline
IDG0+ QWMG
Groove N
IDG1
IDG2
Centreline
Land N+1
IDL0+ QWML
IDL1
IDL2
Centreline
IDG0+ QWMG
Groove N+1
IDG1
IDG2
Centreline DISK INNER Figure 16 – Preformatted Header and wobble groove displacements
Land
IDL0+ QWML
IDL1
IDL2
Centreline Mirror Area
Groove
IDG0+ QWMG
IDG1
IDG2
Centreline Figure 17 – Mirror Area groove interruption
- 39 -
14 14.1
Track format Physical Track layout For Type RW disks, on each track there shall be 14 to 30 sectors per revolution. Each sector shall comprise 122 400 Channel bits. Hence, the length of one Channel bit is determined by the requirement that there are (14 to 30) × 122 400 = 1 713 600 to 3 672 000 Channel bits on a track. The sectors shall be equally spaced over a track in such a way that the distance between the first Channel bit of a sector and the first Channel bit of the next sector shall be 122 400 Channel bits ± 3 Channel bits. At the rotational rate of 32,5 Hz, the period T of a Channel bit equals: 9
10 T =
32,5 × (1 713 600 to 3 672 000)
ns = 17,96 to 8,38 ns
For Type WORM disks, on each track there shall be 13 to 28 sectors per revolution. Each sector shall comprise 121 680 Channel bits. Hence, the length of one Channel bit is determined by the requirement that there are (13 to 28) × 121 680 = 1 581 840 to 3 407 040 Channel bits on a track. The sectors shall be equally spaced over a track in such a way that the distance between the first Channel bit of a sector and the first Channel bit of the next sector shall be 121 680 Channel bits ± 3 Channel bits. At the rotational rate of 35,0 Hz, the period T of a Channel bit equals: 9
T =
10
35,0 × (1 581 840 to 3 407 040)
ns = 18,06 to 8,39 ns
The period of the wobble groove shall be 240 times the Channel clock period for both Type RW and Type WORM media. Tables 2 and 3 list Channel clock and wobble groove timing information for Type RW and Type WORM media, respectively.
14.2
Physical Block Address (PBA) Each sector shall be identified using a unique Physical Block Address (PBA). PBA number 0 shall be located on the land of the first Physical Track that contains Preformatted Headers at a radius 62,50 mm ± 0,10 mm. Each PBA shall be represented by an unsigned 24-bit value. PBA numbers shall be consecutive within a band when read in the following manner: Starting with the first sector on the Land Recording Track in the band and continuing to follow the spiral on the Land Recording Track until the end of the band; Returning to the first sector on the Groove Recording Track within the same band and continuing to follow the spiral on the Groove Recording Track until the end of the band. PBA numbers shall be consecutive at each band boundary. The PBA numbers sharing the same Physical Track shall be related by the following equation: PBA-G = PBA-L + n / 2 where (see 15.2.2) PBA-L is the PBA value recorded in IDL0, IDL1, and IDL2 fields PBA-G is the PBA value recorded in IDG0, IDG1, and IDG2 fields n is the total number of PBAs (sectors) within a band. The PBA mapping for Type RW media shall be according to table 4. The PBA mapping for Type WORM media shall be according to table 5
- 40 -
T able 2 – Nom inal Channel c loc k and wobble gr oove tim ing f or T ype RW m edia at r otational f r equenc y of 32,5 Hz Band
Sectors per revolution
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14
Channel clock frequency (MHz) 119,34 115,36 111,38 107,41 103,43 99,45 95,47 91,49 87,52 83,54 79,56 75,58 71,60 67,63 63,65 59,67 55,69
Channel clock period T (ns) 8,38 8,67 8,98 9,31 9,67 10,06 10,47 10,93 11,43 11,97 12,57 13,23 13,97 14,79 15,71 16,76 17,96
Wobble frequency (kHz)
Wobble period (Fs)
497,25 480,68 464,10 447,53 430,95 414,38 397,80 381,23 364,65 348,08 331,50 314,93 298,35 281,78 265,20 248,63 232,05
2,011 2,080 2,155 2,235 2,320 2,413 2,514 2,623 2,742 2,873 3,017 3,175 3,352 3,549 3,771 4,022 4,309
T able 3 – Nom inal Channel c loc k and wobble gr oove tim ing f or T ype W O RM m edia at r otational f r equenc y of 35,0 Hz Band
Sectors per revolution
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13
Channel clock frequency (MHz) 119,25 114,99 110,73 106,47 102,21 97,95 93,69 89,43 85,18 80,92 76,66 72,40 68,14 63,88 59,62 55,36
Channel clock period T (ns) 8,39 8,70 9,03 9,39 9,78 10,21 10,67 11,18 11,74 12,36 13,04 13,81 14,68 15,65 16,77 18,06
- 41 -
Wobble frequency (kHz)
Wobble period (Fs)
496,86 479,12 461,37 443,63 425,88 408,14 390,39 372,65 354,90 337,16 319,41 301,67 283,92 266,18 248,43 230,69
2,013 2,087 2,167 2,254 2,348 2,450 2,562 2,684 2,818 2,966 3,131 3,315 3,522 3,757 4,025 4,335
T able 4 – Phys ic al Bloc k Addr es s layout of T ype RW Media
62,50 to 60,66
PBA numbers on Land Recording Track 0 to 68 879
PBA numbers on Groove Recording Track 68 880 to 137 759
158 862
60,66 to 58,47
137 760 to 217 190
217 191 to 296 621
5 448
152 544
58,47 to 56,29
296 622 to 372 893
372 894 to 449 165
3
5 420
146 340
56,29 to 54,12
449 166 to 522 335
522 336 to 595 505
4
5 390
140 140
54,12 to 51,97
595 506 to 665 575
665 576 to 735 645
5
5 362
134 050
51,97 to 49,82
735 646 to 802 670
802 671 to 869 695
6
5 332
127 968
49,82 to 47,69
869 696 to 933 679
933 680 to 997 663
7
5 302
121 946
47,69 to 45,57
997 664 to 1 058 636
1 058 637 to 1 119 609
8
5 274
116 028
45,57 to 43,46
1 119 610 to 1 177 623
1 177 624 to 1 235 637
9
5 244
110 124
43,46 to 41,36
1 235 638 to 1 290 699
1 290 700 to 1 345 761
10
5 214
104 280
41,36 to 39,28
1 345 762 to 1 397 901
1 397 902 to 1 450 041
11
5 186
98 534
39,28 to 37,20
1 450 042 to 1 499 308
1 499 309 to 1 548 575
12
5 156
92 808
37,20 to 35,14
1 548 576 to 1 594 979
1 594 980 to 1 641 383
13
5 128
87 176
35,14 to 33,09
1 641 384 to 1 684 971
1 684 972 to 1 728 559
14
5 098
81 568
33,09 to 31,05
1 728 560 to 1 769 343
1 769 344 to 1 810 127
15
5 068
76 020
31,05 to 29,02
1 810 128 to 1 848 137
1 848 138 to 1 886 147
16
5 058
70 812
29,02 to 27,00
1 886 148 to 1 921 553
1 921 554 to 1 956 959
Band
Recording Tracks per band 4 592
Number of PBAs per band 137 760
0 1
5 478
2
Radius (mm)
T able 5 – Phys ic al Bloc k Addr es s layout of T ype W O RM Media
62,50 to 59,92
PBA numbers on Land Recording Track 0 to 97 663
PBA numbers on Groove Recording Track 97 664 to 195 327
163 782
59,92 to 57,67
195 328 to 277 218
277 219 to 359 109
6 044
157 144
57,67 to 55,44
359 110 to 437 681
437 682 to 516 253
3
6 024
150 600
55,44 to 53,21
516 254 to 591 553
591 554 to 666 853
4
6 002
144 048
53,21 to 50,99
666 854 to 738 877
738 878 to 810 901
5
5 982
137 586
50,99 to 48,78
810 902 to 879 694
879 695 to 948 487
6
5 960
131 120
48,78 to 46,57
948 488 to 1 014 047
1 014 048 to 1 079 607
7
5 940
124 740
46,57 to 44,37
1 079 608 to 1 141 977
1 141 978 to 1 204 347
8
5 918
118 360
44,37 to 42,18
1 204 348 to 1 263 527
1 263 528 to 1 322 707
9
5 898
112 062
42,18 to 40,00
1 322 708 to 1 378 738
1 378 739 to 1 434 769
10
5 876
105 768
40,00 to 37,83
1 434 770 to 1 487 653
1 487 654 to 1 540 537
11
5 856
99 552
37,83 to 35 66
1 540 538 to 1 590 313
1 590 314 to 1 640 089
12
5 834
93 344
35 66 to 33,50
1 640 090 to 1 686 761
1 686 762 to 1 733 433
13
5 814
87 210
33,50 to 31,35
1 733 434 to 1 777 038
1 777 039 to 1 820 643
14
5 794
81 116
31,35 to 29,21
1 820 644 to 1 861 201
1 861 202 to 1 901 759
15
5 960
77 480
29,21 to 27,00
1 901 760 to 1 940 499
1 940 500 to 1 979 239
0
Recording Tracks per band 6 976
Number of PBAs per band 195 328
1
6 066
2
Band
Radius (mm)
- 42 -
14.3
Sectors w ith Mirror Area Sectors that include a Mirror Area shall be as specified in table 6 for Type RW media and in table 7 for Type WORM media. Sectors with a Mirror Area span 3 complete Physical Tracks in each of three different bands located near the outer, middle, and inner diameter of the disk. T able 6 – Loc ation of s ec tor s with Mir r or Ar ea f or T ype RW m edia Band
Physical Track numbers
PBA numbers on Groove Recording Track IDG
0
200 to 202
74 880 to 74 969
8
21 162 to 21 164
1 177 624 to 1 177 689
16
42 975 to 42 977
1 937 360 to 1 937 401
T able 7 – Loc ation of s ec tor s with Mir r or Ar ea f or T ype W O RM m edia
14.4
Band
Physical Track numbers
PBA numbers on Groove Recording Track IDG
0
200 to 202
103 264 to 103 347
8
24 497 to 24 499
1 263 528 to 1 263 587
15
46 572 to 46 574
1 961 040 to 1 961 078
Radial alignment The Headers of the sectors in each band shall be radially aligned in such a way that the distance between the first Channel bits of sectors in adjacent Physical Tracks shall be less than 3 Channel bits. The wobble groove in each band shall be radially aligned in such a way that the phase difference of the wobble displacement for adjacent grooves shall be less than 3 Channel bits. The Mirror Area, when present in a sector, shall be radially aligned in such a way that the distance between the first Channel bits of the Mirror Area in the adjacent Physical Tracks that also contain a Mirror Area shall be less than 3 Channel bits. The Headers of the first sector in all bands shall be radially aligned in such a way that the distance between the first Channel bits of the first sectors of each band shall be less than 120 Channel bits.
15 15.1
Sector format Sector layout The Preformatted Header area of each sector consists of 1 892 Channel bits (see figure 18). Sectors shall have one of the two layouts shown in figure 19 and figure 20 depending on the media Type, RW or WORM. The media Type is specified by the cartridge media identification sensor holes (see 10.5.8), and also indicated by byte 23 of the SDI sectors (see 17.4.4). In the Preformatted Header area, each data bit shall be represented by 6 Channel bits. In the Data field area, 8-bit bytes shall be represented by 12 Channel bits. (See clause 16).
- 43 -
Preformatted Header for Land Recording Track
Number of Channel bits
IDL0
QWML
Blank
IDL1
Blank
IDL2
Blank
294
64
358
294
294
294
294
Total Channel bits= 1892
Preformatted Header for Groove Recording Track
Number of Channel bits
Blank
IDG0 QWMG Blank
IDG1
Blank
IDG2
358
294
294
294
294
64
294
Total Channel bits = 1892
IDL, IDG
Number of Channel bits
AM
ID
36
258
Total Channel bits = 294 IDL, IDG = IDL0, IDL1, IDL2, IDG0, IDG1, IDG2 Figure 18 – Preformatted Header format for Type RW and Type WORM media
Pref o rmat t ed Head er
Gap
Guard1
VFO1
Sync
Data field
PA
Guard2
Buffer
TA
12
240 + N
504
12
Number of Channel bits per field 1 892
141
367 – N
960
48
118 224
+M+N
–M–N Total Channel bits = 122 400
M = 0 to 127, N = 0 to 127 (See 15.5, 15.6, and 15.12) Figure 19 – Sector format for Type RW media
Preformatted Header
Gap
VAP
VFO1
Sync
Data field
PA
Buffer
TA
12
256
12
Number of Channel bits per field 1 892
141
255
840
48
118 224
Total Channel bits = 121 680 Figure 20 – Sector format for Type WORM media
- 44 -
15.2
IDL, IDG There shall be six IDL, IDG fields in the Preformatted Header designated as IDL0, IDL1, IDL2, IDG0, IDG1, and IDG2. The position of the six fields shall be as follows: IDL0, IDL1, and IDL2
Located on the centreline of the Land Recording Track with a tolerance of ± 5 nm
IDG0, IDG1, and IDG2
Located on the centreline of the Groove Recording Track with a tolerance of ± 5 nm
The format of these six fields shall be identical and shall contain AM and ID sub-fields (see figure 18). 15.2.1
Address M ark (AM ) The Address Mark shall consist of an embossed pattern that does not occur elsewhere in the ID field. The field is intended to give the drive STOB bit synchronization (see 16.1) for the following ID field. It shall have length of 36 Channel bits with the following pattern: 12T
4T
4T
4T
4T
4T
4T
space mark Figure 21 – Address Mark field pattern
15.2.2
ID The six ID fields shall each contain the PBA number and CRC bytes. Each field shall consist of six bytes with the following contents: 1st byte: Bits 7 to 3
Shall all be assumed to be ZEROs for CRC calculation, but not recorded in the ID field.
Bit 2
Shall specify the groove or land type of ID field, IDG or IDL. When set to 0 it shall mean an IDG field (IDG0, IDG1, or IDG2). When set to 1 it shall mean an IDL field (IDL0, IDL1, or IDL2).
Bits 1 and 0
Shall specify the ID number. When set to 0 it shall mean the ID0 field (IDL0 or IDG0). When set to 1 it shall mean the ID1 field (IDL1 or IDG1). When set to 2 it shall mean the ID2 field (IDL2 or IDG2).
2
nd
byte: This byte shall be the 8 most significant bits of the PBA (PBA 23-16 ).
rd
3 byte: This byte shall be the next 8 most significant bits of the PBA (PBA 15-8 ). th
4 byte: This byte shall be the 8 least significant bits of the PBA (PBA 7-0 ). th
th
5 and 6 bytes: These two bytes shall specify a 16-bit CRC computed over the first four bytes of this field (see Annex F). The most significant bit of each byte shall be recorded first. The 43 ID data bits shall be encoded into 258 Channel bits as defined in 16.1.
- 45 -
15.3
Blank fields There shall be Blank fields, with no marks, in the Preformatted Header as shown in figure 18.
15.4
Quadrature Wobble Marks (QWM) This field of the Preformatted Header shall consist of 64 Channel bits following the ID0 field (IDL0 or IDG0). The QWM field shall consist of long marks with two different patterns as shown on figure 22: Pattern A: Pattern A shall be located on all even numbered Physical Tracks beginning Physical Track number 0. Pattern A shall start with PBA number 0. Pattern B: Pattern B shall be located on all odd numbered Physical Tracks beginning with Physical Track number 1. The QWML field following IDL0 shall be aligned with the centreline of the Land Recording Track with a tolerance of ± 5 nm. The QWMG field following IDG0 shall be aligned with the centreline of the Groove Recording Track with a tolerance of ± 5 nm. The QWM pattern could be used by the drive for control of radial tracking offset (based on the measurement of relative amplitudes of read signal of these patterns, see Annex X). Pattern A 16T
16T
16T
16T
space mark Pattern B 32T
32T
space mark Figure 22 – Quadrature Wobble Mark field patterns
15.5
Gap There shall be a Gap field in each sector. The length of the Gap field is variable for Type RW media, and fixed for Type WORM media. The Gap field is the first field after the Preformatted Header and gives the drive some time for processing after it has finished reading the Header. The length of the Gap field shall be equal to 141 + M + N Channel bits for each sector of Type RW media. The values of M and N are: M = 0 to 127 N = 0 to 127. M and N shall be determined by the Start Position Shift (SPS) random signal generator (see Annex Y). The purpose of changing the length of the gap field is to vary the physical location of the start of data written to the disk. Varying the start position extends the number of rewrite cycles for Type RW recording layer materials. The length of the Gap field shall be equal to 141 Channel bits for each sector of Type WORM media.
- 46 -
The content of the Gap field is not specified, and shall be ignored in interchange.
15.6
Guard There shall be Guard fields in each sector of Type RW media. These fields are not included for sectors of Type WORM media. The Guard1 and Guard2 fields shall be variable in length from 240 to 367 Channel bits: - The length of the Guard1 field shall be equal to 367 – N Channel bits. - The length of the Guard2 field shall be equal to 240 + N Channel bits. where N is a value from 0 to 127 determined by the SPS random signal generator (see Annex Y). The Guard fields shall be written with the following patterns Guard1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 ...
Total = 367 – N Channel bits Guard2 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 ...
Total = 240 + N Channel bits Figure 23 – Guard field patterns
The contents of the Guard fields shall be ignored in interchange.
15.7
Verify and Protect (VAP) There shall be a VAP field in each sector of Type WORM media. This field is not included for sectors of Type RW media. The VAP field shall be equal to 255 Channel bits in length. The VAP field is intended to detect a sector has been previously written and verified, and protect such sectors from accidentally being over-written. The VAP field, if written, shall contain 240 Channel bits of 4T marks and 4T spaces terminated in a 15 Channel bit space (see figure 25). The terminating space allows a buffer between the end of the 4T mark and 4T space pattern and the beginning of the VFO1 field. This buffer is necessary since VFO1 and VAP fields are written at different times. The terminating space also provides some processing time for the drive to check the VAP field prior to writing. 240T 0 0 0 1 0 0 0 1 0 0 0 1 0 0 0 1 0 0 0 1 space mark Figure 24 – VAP field pattern
- 47 -
15T ...
1 0 0 ... 0 0 0
The VAP field shall be read immediately prior to writing any data to a sector. If the VAP field is detected as being written, the write of the sector shall be terminated before the beginning of VFO1. The VAP field shall only be written during the first optional verify pass of the data. The VAP field shall not be written during any other condition or operation.
15.8
VFO1, VFO2 There shall be two fields (see figure 25) designated VFO1 (see 15.1) and VFO2 (see 15.10) to synchronize the VFO. These fields shall be written by the drive when data is recorded in the sector. VFO1 0 1 0 0 1 0 0 1 0 0 1 0 0 1
...
1 0 0 1 0 0 1 0
Total Channel bits: 960 for Type RW media; 840 for Type WORM media VFO2 0 1 0 0 1 0 0 1 0 0 1 0 0 1
...
1 0 0 1 0 0 1 0
Total Channel bits: 600 (for Type RW and Type WORM media) Figure 25 – VFO1, VFO2 field patterns
15.9
Sync The Sync field is intended to allow the drive to obtain byte synchronization for the following Data field. The Sync field content is unique and does not exist elsewhere in data. It shall have length of 48 Channel bits and be recorded with the bit pattern 010 000 001 000 000 010 000 000 010 000 000 010 000 000 100 000
15.10 Data field The Data field is intended for recording user data. It shall consist of 9 852 bytes comprising: 8 192 user bytes, 1 232 bytes for Control, CRC, ECC, 124 bytes for Resync, 249 bytes for Reference, 50 bytes for VFO2, 4 bytes for Extra Sync, and 1 byte for Extra Reference. All bytes in the Data field except Resync, Reference, VFO2, Extra Sync, and Extra Reference fields shall be scrambled in accordance with Annex G. The disposition of these bytes in the Data field shall be as specified in Annex H.
- 48 -
The Data field shall be encoded into Channel bits as defined in 16.2. 15.10.1 User dat a byt es These bytes are at the disposal of the user for recording information. There shall be 8 192 such bytes per sector. 15.10.2 CRC and ECC byt es The Cyclic Redundancy Code bytes and Error Correction Code bytes are used by the error detection and correction system to rectify erroneous data. The ECC shall be a Reed-Solomon code of degree 32. The computation of the check bytes of the CRC and ECC shall be as specified in Annex H. 15.10.3 Co n t rol byt es There shall be 12 Control bytes written after the user data bytes. The location of the Control bytes in the Data field shall be as specified in Annex H. The first 4 bytes (P1) shall be recorded with the 4 bytes Logical Block Address (LBA) of the sector. The second 4 bytes (P2) shall be recorded with the 4 bytes Physical Block Address (PBA) from the ID field of the sector. The remaining 4 bytes (P3) shall be recorded with the 4 bytes Drive Information Record (DIR). The Drive Information Record shall be used as specified in Annex I. 15.10.4 Resync byt es The Resync bytes enable a drive to regain byte synchronization after a large defect in the Data field. Annex J specifies the Resync bytes and the criteria for selection of which of the two patterns is to be used. The Resync fields shall be inserted among the rest of the bytes of the Data field as specified in Annex H. 15.10.5 Ref erence byt e The Reference byte provides 3T read signal amplitude information for the drive data decoder. The Reference bytes may also be used to detect data dropout conditions and identify the location for application of erasure ECC correction. Annex J specifies the Reference byte. The Reference fields shall be inserted among the rest of the Data field as specified in Annex H.
15.11 Postamble (PA) The PA field shall have a nominal length of 12 Channel bits which shall be used for RLL(1,7) closure. This field shall be encoded with the data byte (FF) and end in a space.
15.12 Buffer The Buffer field is used to accommodate the various system tolerances. Causes of variation are as follows: Header-to-Header spacing as specified in 14.1 and the actual length of the written data as determined by the runout of the track, speed variation of the disk, and wobble groove PLL timing error. The length of the Buffer field shall be variable and depends on the length of the SPS random signal generator values M and N for Type RW media, and shall equal 504 – M – N Channel bits. The length of the Buffer field shall be fixed for Type WORM media, and shall equal 256 Channel bits. The minimum Buffer field length is approximately 0,2 % of the total sector length.
- 49 -
15.13 Transition Area (TA) This area is used for transition from the grooved areas to embossed Headers and shall be equal in length to 12 Channel bits. This area shall not contain user information.
16 16.1
Recording codes Preformatted Header The 43 data bits in each of the six ID fields shall be encoded into Channel bits on the disk using the Six Times Oversampled Bi-Phase (STOB) as defined in figure 26. All other Preformatted Header fields in a sector have already been defined in terms of Channel bits. 3T
3T
Bit = ZERO space mark Bit = ONE space mark Figure 26 – STOB bit patterns
16.2
Data field The 8-bit bytes in the Data field shall be encoded into Channel bits on the disk according to table 8 and Annex H. Channel bits in the Data field shall be decoded into information bits according to table 9 and Annex H. All other fields in the Data field have already been defined in terms of Channel bits. Write pulses shall produce a mark in a manner such that the edge between a mark and a space or a space and a mark corresponds to a Channel bit that is a ONE. The recording code used to record all data in the Data fields of the disk shall be the run-length limited code known as RLL(1,7) as defined in tables 8 and 9.
- 50 -
T able 8 - Enc oding of input bits to Channel bits Preceding Channel bit
Current input bits
Group
01
Channel bits RLL(1,7) 100
0 1
01
000
A
x
10
010
A
0
11
101
A
1
11
001
A
0
00 01
100 001
B
1
00 01
000 001
B
0
00 10
100 000
B
1
00 10
000 000
B
x
00 11
010 001
B
x
00 00
010 000
B
A
The coding shall start at the first bit of the first byte of the field to be converted. The preceding Channel bit to the first byte is assumed to be ZERO. Basically two input bits translate into three Channel bits (group A). However, if the two input bits are ZERO ZERO, then the next two input bits are also evaluated, and the four input bits translate into six Channel bits (group B). Resync and Reference fields shall be ignored for encoding of the input data. Resync and Reference bytes must be inserted into the Channel bit data at the proper locations after encoding. The insertion of the Resync and Reference fields does not effect closure of the RLL(1,7) encoded data. Closure of the last data byte occurs in the PA field. T able 9 – Dec oding of Channel bits to inf orm ation bits Preceding Channel bits
Current Channel bits
Following Channel bits
Decoded information bits
xx
010
00
00
xx
010
01 or 10
10
01
000
00
00
01
000
01 or 10
01
10
000
xx
00
00
000
xx
10
xx
100
00
00
xx
100
01 or 10
01
00
001
xx
01
01 or 10
001
xx
11
xx
101
xx
11
- 51 -
Resync and Reference fields shall be ignored for decoding of channel data. Resync and Reference bytes must be removed from the Channel bit data at the proper locations prior to decoding.
17 17.1
Formatted Zone General description of the Formatted Zone The Formatted Zone contains all information on the disk relevant for data interchange. This information comprises embossed tracking provisions, embossed Headers, and possibly user written data. In this clause the term "data" is reserved for the content of the Data field of a sector, which, in general, is transferred to the host. Clause 17 defines the layout of the information. The characteristics of signals obtained from this information are specified in sections 4 and 6.
17.2
Division of the Formatted Zone The Formatted Zone shall be divided into zones at the radius values specified by table 10. These zones shall correspond to PBA numbers indicated in table 11 for Type RW media and table 12 for Type WORM media. The dimensions are given as reference only, and are nominal locations. The tolerance on the location of PBA number 0 is specified in 14.2. The tolerances on the other radii are determined by the tolerance on the track pitch as specified in 13.5. PBA numbers not listed in table 11 and 12 are used to provide boundary guard tracks between bands and buffer tracks between recording zones. These sectors shall not be recorded by the media manufacturer or the drive system. The entire Formatted Zone shall be reflective and have the same recording layer.
- 52 -
T able 10 – Layout of the For m atted Zone by radius Formatted Zone
Radius (mm) Type WORM media Band 62,50 to 62,18 0 62,50 to 62,20
Type RW media Lead-in
Band 0
User Zone 0
0
62,18 to 60,71
0
62,20 to 59,96
Outer Read Focus Offset
0
60,71 to 60,71
0
59,96 to 59,96
Outer Read Reference
0
60,71 to 60,71
0
59,96 to 59,96
Outer Manufacturer
0
60,71 to 60,67
0
59,96 to 59,92
User Zone 1
1
60,66 to 58,47
1
59,92 to 57,68
User Zone 2
2
58,47 to 56,30
2
57,67 to 55,44
User Zone 3
3
56,29 to 54,13
3
55,44 to 53,21
User Zone 4
4
54,12 to 51,97
4
53,21 to 50,99
User Zone 5
5
51,97 to 49,83
5
50,99 to 48,78
User Zone 6
6
49,82 to 47,69
6
48,77 to 46,57
Outer SDI
7
47,69 to 47,69
7
46,57 to 46,57
Outer DDS
7
47,69 to 47,69
7
46,57 to 46,57
User Zone 7 (including DMA)
7
47,69 to 45,58
7
46,57 to 44,38
Inner SDI
7
45,58 to 45,58
7
44,38 to 44,38
Inner DDS
7
45,58 to 45,58
7
44,38 to 44,38
PDL3
7
45,58 to 45,57
7
44,38 to 44,37
User Zone 8
8
45,57 to 43,57
8
44,37 to 42,81
Middle Read Focus Offset
8
43,57 to 43,56
8
42,81 to 42,81
Middle Read Reference
8
43,56 to 43,56
8
42,81 to 42,80
Write Power Calibration
8
43,56 to 43,52
8
42,80 to 42,24
Middle Manufacturer
8
43,52 to 43,46
8
42,24 to 42,18
User Zone 9
9
43,46 to 41,37
9
42,18 to 40,00
User Zone 10
10
41,36 to 39,28
10
40,00 to 37,83
User Zone 11
11
39,28 to 37,21
11
37,82 to 35,66
User Zone 12
12
37,20 to 35,14
12
35,66 to 33,50
User Zone 13
13
35,14 to 33,09
13
33,50 to 31,35
User Zone 14
14
33,09 to 31,05
14
31,35 to 29,21
User Zone 15
15
31,05 to 29,03
15
29,20 to 28,27
User Zone 16
16
29,02 to 28,37
Inner Read Focus Offset
16
28,37 to 28,37
15
28,27 to 28,27
Inner Read Reference
16
28,37 to 28,37
15
28,27 to 28,27
Inner Manufacturer
16
28,37 to 28,28
15
28,27 to 28,18
Lead-out
16
28,28 to 27,00
15
28,18 to 27,00
- 53 -
T able 11 – Layout of the For m atted Zone by Phys ic al Bloc k Addr es s f or T ype RW m edia Formatted Zone
Band
PBA numbers on
PBA numbers on
Land Recording Track
Groove Recording Track
Lead-in
0
0 to 11 999
68 880 to 80 879
User Zone 0
0
12 000 to 67 079
80 880 to 135 959
Outer Read Focus Offset
0
67 080 to 67 169
135 960 to 136 049
Outer Read Reference
0
67 170 to 67 259
136 050 to 136 139
Outer Manufacturer
0
67 290 to 68 789
136 170 to 137 669
User Zone 1
1
137 847 to 217 103
217 278 to 296 534
User Zone 2
2
296 706 to 372 809
372 978 to 449 081
User Zone 3
3
449 247 to 522 254
522 417 to 595 424
User Zone 4
4
595 584 to 665 497
665 654 to 735 567
User Zone 5
5
735 721 to 802 595
802 746 to 869 620
User Zone 6
6
869 768 to 933 607
933 752 to 997 591
Outer SDI
7
997 733 to 977 755
1 058 706 to 1 058 728
Outer DDS
7
997 756 to 997 778
1 058 729 to 1 058 751
User Zone 7 (including DMA)
7
997 779 to 1 058 383
1 058 752 to 1 119 356
Inner SDI
7
1 058 384 to 1 058 406
1 119 357 to 1 119 379
Inner DDS
7
1 058 407 to 1 058 429
1 119 380 to 1 119 402
PDL3 (Groove only)
7
User Zone 8
8
1 119 676 to 1 174 741
1 177 690 to 1 232 755
Middle Read Focus Offset
8
1 174 742 to 1 174 807
1 232 756 to 1 232 821
Middle Read Reference
8
1 174 808 to 1 174 873
1 232 822 to 1 232 887
Write Power Calibration
8
1 174 896 to 1 175 995
1 232 910 to 1 234 009
Middle Manufacturer
8
1 176 018 to 1 177 557
1 234 032 to 1 235 571
User Zone 9
9
1 235 701 to 1 290 636
1 290 763 to 1 345 698
User Zone 10
10
1 345 822 to 1 397 841
1 397 962 to 1 449 981
User Zone 11
11
1 450 099 to 1 499 251
1 499 366 to 1 548 518
User Zone 12
12
1 548 630 to 1 594 925
1 595 034 to 1 641 329
User Zone 13
13
1 641 435 to 1 684 920
1 685 023 to 1 728 508
User Zone 14
14
1 728 608 to 1 769 295
1 769 392 to 1 810 079
User Zone 15
15
1 810 173 to 1 848 092
1 848 183 to 1 886 102
User Zone 16
16
1 886 190 to 1 897 515
1 921 596 to 1 932 921
Inner Read Focus Offset
16
1 897 516 to 1 897 557
1 932 922 to 1 932 963
Inner Read Reference
16
1 897 558 to 1 897 559
1 932 964 to 1 933 005
Inner Manufacturer
16
1 897 614 to 1 899 153
1 933 020 to 1 934 559
Lead-out
16
1 899 154 to 1 921 553
1 934 560 to 1 956 959
1 119 403 to 1 119 540
- 54 -
T able 12 – Layout of the For m atted Zone by Phys ic al Bloc k Addr es s f or T ype W O RM m edia Formatted Zone
Band
PBA numbers on
PBA numbers on
Land Recording Track
Groove Recording Track
Lead-in
0
0 to 11 199
97 664 to 108 863
User Zone 0
0
11 200 to 95 983
108 864 to 193 647
Outer Read Focus Offset
0
95 984 to 96 067
193 648 to 193 731
Outer Read Reference
0
96 068 to 96 151
193 732 to 193 815
Outer Manufacturer
0
96 180 to 97 579
193 844 to 195 243
User Zone 1
1
195 409 to 277 137
277 300 to 359 028
User Zone 2
2
359 188 to 437 603
437 660 to 516 175
User Zone 3
3
516 329 to 591 478
591 629 to 666 778
User Zone 4
4
666 926 to 738 805
738 950 to 810 829
User Zone 5
5
810 971 to 879 625
879 764 to 948 418
User Zone 6
6
948 554 to 1 013 981
1 014 114 to 1 079 541
Outer SDI
7
1 079 671 to 1 079 691
1 142 041 to 1 142 061
Outer DDS
7
1 079 692 to 1 079 712
1 142 062 to 1 142 082
User Zone 7 (including DMA)
7
1 079 713 to 1 141 746
1 142 083 to 1 204 116
Inner SDI
7
1 141 747 to 1 141 767
1 204 117 to 1 204 137
Inner DDS
7
1 141 768 to 1 141 788
1 204 138 to 1 204 158
PDL3 (Groove only)
7
User Zone 8
8
1 204 408 to 1 246 607
1 263 588 to 1 305 787
Middle Read Focus Offset
8
1 246 608 to 1 246 667
1 305 788 to 1 305 847
Middle Read Reference
8
1 246 668 to 1 246 727
1 305848 to 1 305 907
Write Power Calibration
8
1 246 748 to 1 262 047
1 305 928 to 1 321 227
Middle Manufacturer
8
1 262 068 to 1 263 467
1 321 248 to 1 322 647
User Zone 9
9
1 322 765 to 1 378 681
1 378 796 to 1 434 712
User Zone 10
10
1 434 824 to 1 487 599
1 487 708 to 1 540 483
User Zone 11
11
1 540 589 to 1 590 262
1 590 365 to 1 640 038
User Zone 12
12
1 640 138 to 1 686 713
1 686 810 to 1 733 385
User Zone 13
13
1 733 479 to 1 776 993
1 777 084 to 1 820 598
User Zone 14
14
1 820 686 to 1 861 159
1 861 244 to 1 901 717
User Zone 15
15
1 901 799 to 1 918 178
1 940 539 to 1 956 918
Inner Read Focus Offset
15
1 918 179 to 1 918 217
1 956 919 to 1 956 957
Inner Read Reference
15
1 918 218 to 1 918 256
1 956 958 to 1 956 996
Inner Manufacturer
15
1 918 270 to 1 919 699
1 957 010 to 1 958 439
Lead-out
15
1 919 700 to 1 940 499
1 958 440 to 1 979 239
1 204 159 to 1 204 284
- 55 -
17.2.1
L ead - in Z on e The Lead-in Zone shall be used for positioning purposes only. The Lead-in Zone shall comprise 800 Recording Tracks.
17.2.2
Read F o cu s O f f set ( RF O ) Z o n es There shall be an Outer, Middle, and Inner Read Focus Offset Zone on each side of the disk. They are intended to allow drives to adjust the focus offset to the optimal read conditions for the disk. The Read Focus Offset Zones shall be recorded by the media manufacturer, and shall not be written or modified by the drive system. All three of the Read Focus Offset Zones shall contain identical test data patterns as specified in 17.3. The recorded data marks shall satisfy the requirements for signals specified in clause 25.
17.2.2.1 O ut er Read Focus O f f set Zone The Outer Read Focus Offset Zone shall be located in Band 0. The Outer Read Focus Offset Zone shall comprise 6 Recording Tracks. 17.2.2.2 M id dle Read Focus O f f set Zone The Middle Read Focus Offset Zone shall be located in Band 8. The Middle Read Focus Offset Zone shall comprise 6 Recording Tracks. 17.2.2.3 Inner Read Focus O f f set Zone The Inner Read Focus Offset Zone shall be located in Band 16 for Type RW media and in Band 15 for Type WORM media. The Inner Read Focus Offset Zone shall comprise 6 Recording Tracks. 17.2.3
Read Ref erence Zones There shall be an Outer, Middle, and Inner Read Reference Zone on each side of the disk. They are intended to allow drives to quantify the read performance (byte error rate) and PLL jitter. The Read Reference Zones shall be recorded by the media manufacturer, and shall not be written or modified by the drive system. All three of the Read Reference Zones shall contain identical test data patterns as specified in 17.3. The recorded data marks shall satisfy the requirements for signals specified in clause 25.
17.2.3.1 O ut er Read Ref erence Zone The Outer Read Reference Zone shall be located in Band 0. The Outer Read Reference Zone shall comprise 6 Recording Tracks. 17.2.3.2 M id dle Read Ref erence Zone The Middle Read Reference Zone shall be located in Band 8. The Middle Read Reference Zone shall comprise 6 Recording Tracks. 17.2.3.3 Inner Read Ref erence Zone The inner Read Reference Zone shall be located in Band 16 for Type RW media and in Band 15 for Type WORM media. The Inner Read Reference Zone shall comprise 6 Recording Tracks. 17.2.4
M anuf act urer Zones There shall be an Outer, Middle, and Inner Manufacturer Zone on each side of the disk. They are provided to allow the media manufacturers to perform tests on the disk, including read and write calibration operations, in areas located away from that intended for user recorded information. The sectors contained in the Manufacturer Zones may be used at the discretion of the media manufacturer. - 56 -
The Manufacturer Zones are intended for quality tests by the media manufacturer. They should not be used by drives and shall be ignored in interchange. 17.2.4.1 O u t er M an u f act u rer Z o n e The Outer Manufacturer Zone shall be located in Band 0. The Outer Manufacturer Zone shall comprise 100 Recording Tracks. 17.2.4.2 M iddle M anuf act urer Zone The Middle Manufacturer Zone shall be located in Band 8. The Middle Manufacturer Zone shall comprise 140 Recording Tracks. 17.2.4.3 In n er M an u f act u rer Z o n e The Inner Manufacturer Zone shall be located in Band 16 for Type RW media and in Band 15 for Type WORM media. The Inner Manufacturer Zone shall comprise 220 Recording Tracks. 17.2.5
SDI Zones The two, Outer and Inner, SDI Zones on each side of the disk shall be used for recording Specific Disk Information (see 17.4). The SDI Zones shall consist of sectors recorded by the same modulation method and format as is used in the User Zone (see clauses 15 and 16).
17.2.5.1 O ut er SDI Zone The Outer SDI Zone shall be located near the outer radius of Band 7. The Outer SDI Zone shall comprise 2 Recording Tracks. 17.2.5.2 Inner SDI Zone The Inner SDI Zone shall be located near the inner radius of Band 7. The Inner SDI Zone shall comprise 2 Recording Tracks. 17.2.6
DDS Zones The two, Outer and Inner, DDS Zones on each side of the disk shall be used for recording the Disk Definition Structure (see 18.5). The DDS Zones shall consist of sectors recorded by the same modulation method and format as is used in the User Zone (see clauses 15 and 16).
17.2.6.1 O ut er DDS Zone The Outer DDS Zone shall be located near the outer radius of Band 7. The Outer DDS Zone shall comprise 2 Recording Tracks. 17.2.6.2 Inner DDS Zone The Inner DDS Zone shall be located near the inner radius of Band 7. The Inner DDS Zone shall comprise 2 Recording Tracks. 17.2.7
PDL3 Zone The PDL3 Zone shall be located near the inner radius of Band 7. The PDL3 Zone shall be used to record a redundant version of the two Primary Defect Lists (PDL1 and PDL2) that are contained in the Defect Management Area (see 18.4). The PDL3 Zone shall comprise 6 Groove Recording Tracks. The 7 adjacent Land Recording Tracks shall not be recorded.
17.2.8
W rit e Pow er Calibrat ion Z one The Write Power Calibration Zone is intended for tests to enable a drive to optimize its write power and shall not be used by media manufacturers. - 57 -
The Write Power Calibration Zone shall be located in Band 8. The Write Power Calibration Zone shall comprise 100 Recording Tracks for Type RW media and 1 530 Recording Tracks for Type WORM media. For Type RW media, the tracks and sectors used for testing should be chosen from the Write Calibration Zone in a random way, so as to ensure a gradual degradation of the entire Write Calibration Zone due to use. Then each track in this zone will remain representative for the characteristics of the tracks in the User Zones of the disk. For Type WORM media, the sectors should be used sequentially by PBA for Land Recording Tracks until depleted, and then followed sequentially by PBA for Groove Recording Tracks within the Write Calibration Zone. The recommended write power calibration data test pattern is specified in 17.3. The Write Power Calibration Zone shall be ignored in interchange. 17.2.9
User Zo nes The Data fields in the User Zones shall contain user written data in the format of clause 15. The layout of the User Zones and their sub-divisions is specified in clause 18.
17.2.10 L ead - o u t Z on e The Lead-out Zone shall be used for positioning purposes only. The Lead-out Zone shall comprise 3 200 Recording Tracks.
17.3
Drive test data patterns The test patterns used to perform drive calibration for optimal read and write performance are listed in table 13. The purpose of the test patterns is to generate specific encoded channel patterns that can be used to evaluate read signal characteristics. The test data patterns used in the Read Focus and Read Reference zones shall be as specified in table 13. They shall be written under the following special conditions: -
Test sectors shall be written with data scrambler and ECC disabled/enabled as shown on table 13.
-
The Control bytes, CRC bytes, and ECC parity bytes of test sectors shall be written with the test pattern when ECC is disabled.
-
The test user data pattern shall be repeated to fill the entire Data field of test sectors.
The suggested write power calibration test pattern consists of a repeated 8T mark and 8T space without inserted synchronization fields (Sync and Resync). This is an illegal data pattern for the RLL(1,7) encoder / decoder. The test pattern is recorded with varying write power within a single sector to determine the optimal recording power. T able 13 – Dr ive T es t Zone data patterns Drive test zones
Write power
Data scrambler
ECC
User data pattern
Encoded channel pattern
Read Focus Offset zones
Nominal
Disabled
Disabled
(BB BB AA AA AA AA 00 00)
2T-3T-6T
Read Reference zones
Nominal
Enabled
Enabled
(00)
Pseudo-random
Write Power Calibration zone
Varying
8T- 8T (suggested)
- 58 -
17.4
SDI Zones usage The two SDI Zones shall be recorded using the thermo-optical Phase Change recording method in the sector format specified in clause 15. The recorded data marks shall satisfy the requirements for signals specified in clause 25. Both of the SDI Zones shall be recorded by the media manufacturer, and shall not be written or modified by the drive system. Both of the SDI Zones shall contain identical information.
17.4.1
SDI amendment The SDI Zones shall initially be recorded only in every fourth sector, as shown in tables 14 and 15. The media manufacturer may use the three unrecorded sectors between the recorded sectors to allow for amendment of the SDI data. Up to three amendments to the SDI can be made. The disk drive system shall use the latest amended SDI data, as determined by the sectors that have been written. Table 14 and 15 list the Physical Block Addresses of the SDI sectors for the initial and amended cases, for Types RW and WORM media. T able 14 – SDI Sec tor s by Phys ic al Bloc k Addres s f or T ype RW m edia Outer SDI Zone Initial
Amend 1
Amend 2
Inner SDI Zone Amend 3
Initial
Land PBA numbers
Amend 1
Amend 2
Amend 3
Land PBA numbers
997 733 997 737 997 741 997 745 997 749
997 734 997 735 997 738 997 739 997 742 997 743 997 746 997 747 997 750 997 751 Groove PBA numbers
997 736 997 740 997 744 997 748 997 752
1 058 384 1 058 388 1 058 392 1 058 396 1 058 400
1 058 385 1 058 386 1 058 389 1 058 390 1 058 393 1 058 394 1 058 397 1 058 398 1 058 401 1 058 402 Groove PBA numbers
1 058 387 1 058 391 1 058 395 1 058 399 1 058 403
1 058 706 1 058 710 1 058 714 1 058 718 1 058 722
1 058 707 1 058 711 1 058 715 1 058 719 1 058 723
1 058 709 1 058 713 1 058 717 1 058 721 1 058 725
1 119 357 1 119 361 1 119 365 1 119 369 1 119 373
1 119 358 1 119 362 1 119 366 1 119 370 1 119 374
1 119 360 1 119 364 1 119 368 1 119 372 1 119 376
1 058 708 1 058 712 1 058 716 1 058 720 1 058 724
1 119 359 1 119 363 1 119 367 1 119 371 1 119 375
T able 15 – SDI Sec tor s by Phys ic al Bloc k Addres s f or T ype W O RM m edia Outer SDI Zone Initial
Amend 1
Amend 2
Inner SDI Zone Amend 3
Initial
Land PBA numbers
Amend 1
Amend 2
Amend 3
Land PBA numbers
1 079 671 1 079 675 1 079 679 1 079 683 1 079 687
1 079 672 1 079 673 1 079 676 1 079 677 1 079 680 1 079 681 1 079 684 1 079 685 1 079 688 1 079 689 Groove PBA numbers
1 079 674 1 079 678 1 079 682 1 079 686 1 079 690
1 141 747 1 141 751 1 141 755 1 141 759 1 141 763
1 141 748 1 141 749 1 141 752 1 141 753 1 141 756 1 141 757 1 141 760 1 141 761 1 141 764 1 141 765 Groove PBA numbers
1 141 750 1 141 754 1 141 758 1 141 762 1 141 766
1 142 041 1 142 045 1 142 049 1 142 053 1 142 057
1 142 042 1 142 046 1 142 050 1 142 054 1 142 058
1 142 044 1 142 048 1 142 052 1 142 056 1 142 060
1 204 117 1 204 121 1 204 125 1 204 129 1 204 133
1 204 118 1 204 122 1 204 126 1 204 130 1 204 134
1 204 120 1 204 124 1 204 128 1 204 132 1 204 136
1 142 043 1 142 047 1 142 051 1 142 055 1 142 059
- 59 -
1 204 119 1 204 123 1 204 127 1 204 131 1 204 135
17.4.2
LBA Co nt rol Byt es in SDI sectors SDI sectors shall be recorded with the four LBA Control Bytes (P1) (see 15.10.3) set as follows: LBA = PBA + (80000000). SDI sectors are located at fixed PBAs, and shall not be remapped to alternate locations.
17.4.3
17.4.4
17.5
Paramet ric condit ions The media read, write, and erase parameters contained in the SDI Zones shall be determined under the following conditions: -
Environment: Test environment (see 8.1.1).
-
Optical beam: As defined in 9.2.
-
Disk rotation: As defined in 9.5.
Sp ecif ic Disk Inf ormat ion SDI sectors shall consist of 8 192 bytes that contain Specific Disk Information as defined in Annex K.
DDS Zones Usage The two DDS Zones shall be recorded using the thermo-optical Phase Change recording method in the sector format specified in clause 15. The recorded data marks shall satisfy the requirements for signals specified in clause 25. The media manufacturer shall record both of the DDS Zones during the disk certification process. Both of the DDS Zones shall contain identical information. For Type RW media, the DDS shall be rewritten by the drive system during a format process. For Type WORM media, the DDS shall not be written or modified by the drive system after disk format.
17.5.1
DDS Amendment The DDS Zones shall initially be recorded only in every fourth sector, as shown in table 16 and 17. The media manufacturer may use the three unrecorded sectors between the recorded sectors to allow for amendment of the DDS data. Up to three amendments to the DDS can be made. The disk drive system shall use the latest amended DDS data, as determined by the sectors that have been written. Table 16 and 17 list the PBAs of the DDS sectors for the initial and amended cases. T able 16 – DDS Sec tor s by Phys ic al Bloc k Addr es s f or T ype RW Media Initial
997 756 997 760 997 764 997 768 997 772 1 058 729 1 058 733 1 058 737 1 058 741 1 058 745
Outer DDS Zone Amend 1 Amend 2 Land PBA numbers 997 757 997 758 997 761 997 762 997 765 997 766 997 769 997 770 997 773 997 774 Groove PBA numbers 1 058 730 1 058 731 1 058 734 1 058 735 1 058 738 1 058 739 1 058 742 1 058 743 1 058 746 1 058 747
Amend 3
Initial
997 759 997 763 997 767 997 771 997 775
1 058 407 1 058 411 1 058 415 1 058 419 1 058 423
1 058 732 1 058 736 1 058 740 1 058 744 1 058 748
1 119 380 1 119 384 1 119 388 1 119 392 1 119 396
- 60 -
Inner DDS Zone Amend 1 Amend 2 Land PBA numbers 1 058 408 1 058 409 1 058 412 1 058 413 1 058 416 1 058 417 1 058 420 1 058 421 1 058 424 1 058 425 Groove PBA numbers 1 119 381 1 119 382 1 119 385 1 119 386 1 119 389 1 119 390 1 119 393 1 119 394 1 119 397 1 119 398
Amend 3 1 058 410 1 058 414 1 058 418 1 058 422 1 058 426 1 119 383 1 119 387 1 119 391 1 119 395 1 119 399
T able 17 – DDS Sec tor s by Phys ic al Bloc k Addr es s f or T ype W O RM Media Initial 1 079 692 1 079 696 1 079 700 1 079 704 1 079 708 1 142 062 1 142 066 1 142 070 1 142 074 1 142 078 17.5.2
Outer DDS Zone Amend 1 Amend 2 Land PBA numbers 1 079 693 1 079 694 1 079 697 1 079 698 1 079 701 1 079 702 1 079 705 1 079 706 1 079 709 1 079 710 Groove PBA numbers 1 142 063 1 142 064 1 142 067 1 142 068 1 142 071 1 142 072 1 142 075 1 142 076 1 142 079 1 142 080
Amend 3
Initial
1 079 695 1 079 699 1 079 703 1 079 707 1 079 711
1 141 768 1 141 772 1 141 776 1 141 780 1 141 784
1 142 065 1 142 069 1 142 073 1 142 077 1 142 081
1 204 138 1 204 142 1 204 146 1 204 150 1 204 154
Inner DDS Zone Amend 1 Amend 2 Land PBA numbers 1 141 769 1 141 770 1 141 773 1 141 774 1 141 777 1 141 778 1 141 781 1 141 782 1 141 785 1 141 786 Groove PBA numbers 1 204 139 1 204 140 1 204 143 1 204 144 1 204 147 1 204 148 1 204 151 1 204 152 1 204 155 1 204 156
Amend 3 1 141 771 1 141 775 1 141 779 1 141 783 1 141 787 1 204 141 1 204 145 1 204 149 1 204 153 1 204 157
LBA Cont rol Byt es in DDS sect ors DDS sectors shall be recorded with the four LBA Control Bytes (P1) (see 15.10.3) set as follows: LBA = PBA + (80000000). DDS sectors are located at fixed PBAs, and shall not be remapped to alternate locations.
17.5.3
18 18.1
DDS in f o rmat io n The DDS sector shall be recorded with data bytes as specified in 18.5.
Layout of the User Zones General description of the User Zones The total data capacity of the User Zones is 15,0 Gbytes per side for both Type RW and Type WORM disks. The location and size of the User Zones are specified in clause 17.
18.2
Divisions of the User Zones The User Zones shall be divided into bands as a result of the ZCAV organization of the disk. There shall be 17 bands numbered 0 to 16 for Type RW media There shall be 16 bands numbered 0 to 15 for Type WORM media. Each User Zone is further divided into two groups of contiguous PBA numbers, one group for groove tracks, and one group for land tracks (see tables 18 and 19).
18.3
User Area The Data fields in the User Area are intended for recording of the user data. The User Area shall be either: a Rewritable Zone (Type RW media) intended for writing and rewriting of user data or a Write Once Read Many Zone (Type WORM media) intended for write once recording of user data.
- 61 -
A contiguous block of Land Recording Track sectors of User Zone 7 shall be included in a Defect Management Area (DMA). The User Area and DMA shall include only the PBA numbers specified in tables 18 and 19. Sectors in the User Zones that are not specified as part of the User Area or DMA shall not be recorded by media manufacturers or the drive system. T able 18 – Us er Ar ea Data G r oups and DMA loc ation f or T ype RW m edia Data Group (Band – Land / Groove)
Sectors per Data Group
Start PBA
End PBA
0–L 55080 12 000 67 079 0–G 55080 80 880 135 959 1–L 79 257 137 847 217103 1–G 79 257 217 278 296 534 2–L 76 104 296 706 372 809 2–G 76 104 372 978 449 081 3–L 73 008 449 247 522 254 3 –G 73 008 522 417 595 424 4–L 69 914 595 584 665 497 4–G 69 914 665 654 735 567 5–L 66 875 735 721 802 595 5–G 66 875 802 746 869 620 6–L 63 840 869 768 933 607 6–G 63 840 933 752 997 591 DMA (L only) 36 800 997 779 1 034 578 7–L 23 805 1 034 579 1 058 383 7–G 60 605 1 058 752 1 119 356 8–L 55 066 1 119 676 1 174 741 8–G 55 066 1 177 690 1 232 755 9–L 54 936 1 235 701 1 290 636 9–G 54 936 1 290 763 1 345 698 10 – L 52 020 1 345 822 1 397 841 10 – G 52 020 1 397 962 1 449 981 11 – L 49 153 1 450 099 1 499 251 11 – G 49 153 1 499 366 1 548 518 12 – L 46 296 1 548 630 1 594 925 12 – G 46 296 1 595 034 1 641 329 13 – L 43 486 1 641 435 1 684 920 13 – G 43 486 1 685 023 1 728 508 14 – L 40 688 1 728 608 1 769 295 14 – G 40 688 1 769 392 1 810 079 15 – L 37 920 1 810 173 1 848 092 15 – G 37 920 1 848 183 1 886 102 16 – L 11 326 1 886 190 1 897 515 16 – G 11 326 1 921 596 1 932 921 Total Number of Sectors in the User Area Data Groups (Excluding DMA) = 1 834 348
- 62 -
T able 19 – Us er Ar ea Data G r oups and DMA loc ation f or T ype W O RM m edia Data Group (Band – Land / Groove)
Sectors per Data Group
Start PBA
End PBA
0–L 84 784 11200 95 983 0–G 84 784 108 864 193 647 1–L 81 729 195 409 277 137 1 –G 81 729 277 300 359 028 2–L 78 416 359 188 437 603 2–G 78 416 437 760 516 175 3–L 75 150 516 329 591 478 3–G 75 150 591 629 666 778 4–L 71 880 666 926 738 805 4–G 71 880 738 950 810 829 5–L 68 655 810 971 879 625 5–G 68 655 879 764 948 418 6–L 65 428 948 554 1 013 981 6–G 65 428 1 014 114 1 079 541 DMA (L only) 36 750 1 079 713 1 116 462 7–L 25 284 1 116 463 1 141 746 7–G 62 034 1 142 083 1 204 116 8–L 42 200 1 204 408 1 246 607 8–G 42 200 1 263 588 1 305 787 9–L 55 917 1 322 765 1 378 681 9–G 55 917 1 378 796 1 434 712 10 – L 52 776 1 434 824 1 487 599 10 – G 52 776 1 487 708 1 540 483 11 – L 49 674 1 540 589 1 590 262 11 – G 49 674 1 590 365 1 640 038 12 – L 46 576 1 640 138 1 686 713 12 – G 46 576 1 686 810 1 733 385 13 – L 43 515 1 733 479 1 776 993 13 – G 43 515 1 777 084 1 820 598 14 – L 40 474 1 820 686 1 861 159 14 – G 40 474 1 861 244 1 901 717 15 – L 16 380 1 901 799 1 918 178 15 – G 16 302 1 940 539 1 956 840 Total Number of Sectors in the User Area Data Groups (Excluding DMA) = 1 834 348
- 63 -
18.4
Defect Management Area (DMA) The Defect Management Area (DMA) is used to manage media defects found during media initialization as well as defects found dynamically during user writes. The DMA shall be divided in the following sub-areas: Primary Defect List 1 (PDL1) Area, Secondary Defect List (SDL) Area, Primary Spares Area (PSA), Secondary Spares Area (SSA), SDL Duplicate Pages (SDLDP) Area, and Primary Defect List 2 (PDL2) Area. The DMA layout shall be as shown in table 20. Each sub-area shall immediately follow the preceding one except for PSA, SSA and SDLDP Areas which shall be preceded by a 1-sector pad.
18.4.1
Primary Def ect List ( PDL) Area The PDL Area shall store in the PDL Pages two copies, PDL1, PDL2, of the list of defective sectors found during media certification (see 19.5). A third copy shall be written in PDL3 (see 17.2.7). The PDL3 Area, which is not part of the DMA, is recorded in a dedicated area located near the inner diameter of Band 7. The redundant copies shall be used for recovery should any PDL sector become damaged. The size of PDL1 Area shall be established when it is written and shall be the actual number of sectors used (both good and bad) in writing the PDL. At least 1 sector shall be used for PDL1. The size of PDL2 Area shall be: 2 · rounded-up (number of Primary Defects / number of entries per PDL Page) The size of the PDL2 Area accommodates twice the number of PDL Pages required for the Primary Defect List, in the event that some sectors in this area may be defective. If certification is not performed or no defective sectors are found during certification, 1 sector shall be used for PDL2.
18.4.2
Secondary Def ect List ( SDL) Area The SDL Area shall store in the SDL Pages the list of defective sectors found during user data writes (see 19.6). The size of the SDL Area shall be: 2 · rounded-up [(DMA size – PDL1 size – PDL2 size – estimated PSA size – Pad Sectors) / maximum entries per SDL Page)] The size of the SDL Area accommodates twice the number of SDL Pages required for the number of sectors remaining in the SSA, in the event that some sectors in this area may be defective. For Type WORM media, a new SDL Page shall be recorded after a group of sectors (by example 250) has been written into the SSA. The complete Secondary Defect List shall be determined by reading the SDL Area and also scanning the SSA for any sectors which have not yet been recorded into an SDL Page.
18.4.3
SDL Duplicat e Pages ( SDLDP) Area The SDL Duplicate Pages (SDLDP) Area shall store a copy of the content of the SDL for recovery in the case of damaged SDL sectors The SDLDP Area size shall be equal to the SDL Area size.
18.4.4
Primary Spares Area ( PSA) The Primary Spares Area (PSA) shall contain sectors that are slipped due to defects found during media certification. The PSA size shall be equal to the number of Primary Defects in the User Zones and the PSA. The estimated PSA size shall be defined as the number of sectors required to relocate the Primary Defects in the User Zones. - 64 -
The actual PSA size shall be increased by 1 sector for each Primary Defect in the PSA. In the event that there are no Primary Defects in the User Zones, 1 sector shall be used for the PSA. 18.4.5
Secondary Spares Area ( SSA) The Secondary Spares Area (SSA) shall contain sectors automatically relocated during writing. The SSA Area size shall be equal to the size of the DMA Areas minus the size of all other subareas and the pad sectors. T able 20 – Def ec t Managem ent Ar ea layout Location
Start PBA
Contents
(1)
PDL1 SDL
(2)
Pad sector
DMA (Defect Management Area)
(2)
2 · rounded-up [(DMA size – PDL1 size – PDL2 size – estimated PSA size – 3 Pad Sectors) / maximum entries per SDL Page] 1 PBA PSA = Number of defective sectors found in bands and PSA during initialization. At least 1 sector is used for the PSA Area.
Pad sector SSA
(2)
Pad sector SDLDP End PBA
Actual number of sectors used in writing PDL. At least 1 sector shall be used.
(2)
PSA
Reserved area size
PDL2
(2)
(2)
1 PBA DMA size – all other sub-areas and pad sectors size within DMA 1 PBA Same size as SDL 2 · rounded-up [(number of Primary Defects / Number of entries per PDL Page] At least 1 sector shall be used.
1. This area shall have the indicated dedicated PBA area on the disk. The actual start PBA of valid data for this area however, is indicated in the DDS. The start PBA in this table and the start PBA given in the DDS may be different as an error could occur in writing the first PBA(s) in this area, such that the first PBA(s) are not valid. The DDS structure points to the first valid (“good”) PBA in this area. 2. The actual Start and End PBAs for the sub-areas are recorded in DDS and may differ from the reserved spaces listed above.
18.5
Disk Definition Structure (DDS) The DDS shall consist of a table with a length of 1 sector. It specifies the location of the Defect Management entities, provides information about the drive that wrote it, and provides information concerning Secondary Defect List (SDL) Page handling. The DDS shall be recorded as specified in 17.5. Table 21 specifies the format of a DDS sector.
- 65 -
T able 21 – DDS Sec tor f or m at Byte
Contents
0-1
DDS Identifier ((A5A5))
2
DDS Format Revision
3 - 10
Vendor Identification (MSB – LSB) (ASCII)
11 - 26
Product Identification (MSB – LSB) (ASCII)
27 - 30
Product Revision Level (MSB – LSB) (ASCII)
31 - 34
Drive Serial Number (MSB – LSB)
35 - 38
Start of PDL1 (MSB - LSB) (PBA)
39 - 42
End of PDL1 (MSB - LSB) (PBA)
43
PDL1 Valid Flag
44 - 59
PDL1 Good Sector Bitmap
60 - 63
Start of SDL (MSB - LSB) (PBA)
64 - 67
End of SDL (MSB – LSB) (PBA)
68 - 69
Maximum entries per SDL Page (MSB - LSB)
70 - 73
Start of Primary Spares (MSB - LSB) (PBA)
74 - 77
End of Primary Spares (MSB – LSB) (PBA)
78 - 81
Start of Secondary Spares (MSB - LSB) (PBA)
82 - 85
End of Secondary Spares (MSB - LSB) (PBA)
86 - 89
Start of SDL Duplicated Pages (MSB - LSB) (PBA)
90 - 93
End of SDL Duplicated Pages (MSB - LSB) (PBA)
94 - 97
Start of PDL2 (MSB – LSB) (PBA)
98 - 101
End of PDL2 (MSB – LSB) (PBA)
102
PDL2 Valid Flag
103 - 118
PDL2 Good Sector Bitmap
119 - 122
Start of PDL3 (MSB - LSB) (PBA)
123 - 126
End of PDL3 (MSB - LSB) (PBA)
127
PDL3 Valid Flag
128 - 143
PDL3 Good Sector Bitmap
144 - 8189
Unspecified
8190 - 8191
DDS Identifier Complement ((5A5A))
The DDS Format Revision, Vendor Identification, Product Identification, Product Revision, and Drive Serial Number fields shall contain implementation specific information that shall be ignored for the purposes of interchange.
- 66 -
The Start of PDLn fields shall contain the PBA of the first good block in the corresponding PDL. In the event that the first page of a PDL set cannot be written, (7FFFFFFF) shall be used, as the starting PBA and the Valid Flag shall be set to ZERO. The End of PDLn fields shall contain the PBA of the last good block in the corresponding PDL. The PDLn Valid Flag fields shall contain a ONE when the corresponding PDL is valid and a ZERO when invalid. All other values for the Valid Flag field are forbidden. The purpose of the PDLn Good Sector Bitmap fields is to provide information useful in determining what sectors in the PDL must be read. The status of each sector in the PDL can be determined by examining the corresponding bit in the bitmap. Good sectors have the bit set, whereas bad sectors do not.
19
Defect Management in the Rewritable (RW) and Write Once Read Many (WORM) Zones Defective sectors on the disk shall be replaced by good sectors according to the Defect Management scheme described below. Each side of the disk shall be initialized before use. This Ecma standard allows media initialization with or without certification. A sector Slipping Algorithm handles defective sectors found during certification. A Linear Replacement Algorithm handles defective sectors found after initialization. The total number of sectors on a side of the disk replaced by the sector Slipping Algorithm shall not exceed half the number of DMA sectors. The total number of sectors on a side of the disk replaced by both algorithms shall not exceed the number of DMA sectors.
19.1
Initialization of the disk During initialization of the disk, the DMA is partitioned and the DDSs and PDLs are recorded prior to the first use of the disk. The User Area is divided into bands, each containing only data sectors. Media initialization can include a certification of the RW bands and the WORM bands, whereby defective sectors are identified and skipped. For Type WORM media only a single initialization is allowed. Once the DDSs and PDLs are recorded, it indicates that the disk is initialized and no further initialization is permitted. For Type WORM media, all sectors in the WORM bands, the PSA, the SSA, the SDL, and the SDLDP shall be in the blank state at the end of initialization. For Type RW media, all sectors in the SDL, the SDLDP, and the SSA shall be in the erased state at the end of initialization. All DDS parameters shall be recorded in all of the DDS sectors as specified in 17.5. The PDLs shall be recorded in the areas defined in 18.4. The contents of the PDLs and SDLs shall be as shown in tables 23 and 24 (see page 67 and 68).
19.2
Certification If the disk is certified, the certification shall at a minimum be applied to all sectors of the RW and WORM bands in the User Area. This Ecma Standard does not state the method of certification. It may involve, erasing, writing, and reading of sectors. The Slipping Algorithm (see 19.2.1) shall handle defective sectors found during certification. Defective sectors shall not be used for reading or writing in the User Area. Guidelines for replacing defective sectors are given in Annex Z.
19.2.1
Slip p in g Alg o rit h m The Slipping Algorithm shall be applied across each band of the disk if certification is performed. For PBAs less than the start PBA of the DMA, defective data sectors found during certification shall be replaced by the first good sector following the defective sector within the current band, thus causing a slip of one sector towards the DMA. In the case where a sector slips out of a band, with the exception of the last band before the DMA, the replacement sector shall be the - 67 -
first sector of the next band, and so causes a slip of one sector towards the DMA. Sectors slipping out of the band immediately before the DMA are slipped into the PSA. The slip count will increase as the PBA increases. For PBAs higher than the start PBA of the DMA, defective data sectors found during certification shall be replaced by the first good sector preceding the defective sector within the current band, thus causing a slip of one sector towards the DMA. In the case where a sector slips out of the beginning of a band, with the exception of the first band after the DMA, the replacement sector shall be the last sector of the preceding band, and so causes a slip of one sector towards the DMA. Sectors slipping out of the band immediately after the DMA are slipped into the PSA from the tail end. The slip count will increase as the PBA decreases. Table 22 shows a simplified example of the Slipping Algorithm for a greatly shortened PBA range over several bands including the DMA and PSA. T able 22 – Sec tor Slipping Algor ithm ex am ple Band 0 PBA
0
LBA
0
Bad
1
Band 1 2
10
11
1
2
3
X
DMA – PSA 12
Band 2
20
21
22
23
30
31
4
5
6
7
8
9
X
Band 3 32
40
41
10 X
42 11
X
The address of each defective sector shall be written in the PDLs. If no defective sectors are found during certification, an empty PDL shall be recorded. As the PSA grows, the SSA is diminished accordingly. All replacements performed using the Slipping Algorithm are done without regard for land or groove. 19.2.2
Linear Replacement Algorit hm The Linear Replacement Algorithm is used to handle defective sectors found after certification. The defective sector shall be replaced by the first available sector in the SSA. As with the Slipping Algorithm, replacement shall be done without regard for land or groove. If a replacement sector is found to be defective, it shall be replaced by the next available spare sector. The next available spare sector does not have to be the next PBA. The address of the defective sector shall be recorded in the SDL in the appropriate position so that the replacement sector PBA can be calculated from the entry position and the “First Spare in this Page” field in the SDL Page. The addresses of sectors already recorded in the PDL shall not be recorded in the SDL. If a replacement sector listed in the SDL is later found to be defective, it shall be dealt with by making a new entry in the SDL indicating a replacement sector for the defective replacement sector.
19.3
Disk not certified The Linear Replacement Algorithm is used to handle sectors found defective on disks, which have not been certified. The defective sector shall be replaced by the first available sector in the SSA. If a replacement sector is found to be defective, it shall be replaced by the next available spare sector. The next available spare sector does not have to be the next PBA. The address of the defective sector shall be recorded in the SDL in the appropriate position so that the replacement sector PBA can be calculated from the entry position and the “First Spare in this Page” field in the SDL Page. If a replacement sector listed in the SDL is later found to be defective, it shall be dealt with by making a new entry in the SDL indicating a replacement sector for the defective replacement sector. - 68 -
19.4
Write procedure When writing data in the sectors of a band, all defective sectors listed in the PDL shall be skipped and the data shall be recorded in the appropriate sector in accordance with the Slipping Algorithm. If a sector to be written is listed in the SDL, the data shall be written in the spare sector pointed to by the SDL, according to the Linear Replacement Algorithm. When writing in the PSA, all defective sectors listed in the PDL shall be skipped and the data shall be relocated using the Slipping Algorithm. When writing the DDS, PDL, SDL, and in the SSA, all defective sectors listed in the PDL shall be skipped and written in the next available sector in the affected area. For Type WORM after initialization, all sectors in the User Area shall be in the blank state. Erasing of sectors on Type WORM media is not permitted. If the sector has been written, a write operation is not permitted. During write operations, sectors shall always be recorded with CRC, ECC, and Control Record information as specified by this Ecma Standard. See Annex AA for guidelines for the use of Type WORM media.
19.5
Primary Defect List (PDL) format and content The PDL shall consist of bytes specifying -
the format revision of the PDL,
-
information about the drive type that wrote the PDL,
-
a PDL Page sequence number,
-
the number of entries in the entire PDL,
-
the PBAs of the defective sectors, identified at initialization, in ascending order,
-
a vendor unique defect code for each defective sector,
-
the drive serial number of the drive that found each defective sector.
Table 23 shows the PDL byte layout. All remaining defect entries in the last page of the PDL shall have the PBA set to (7FFFFFFF), the Defect Cause set to (FF), and the Drive Serial Number set to (FFFFFF). If no defective sectors are detected, the Number of Defective Sectors field shall be set to ZERO. During initialization, a PDL shall be recorded; this PDL may be empty.
- 69 -
T able 23 – Pr im ary Def ec t Lis t Page f or m at Byte
Contents
0-1 2 3 - 10 11 - 26 27 - 30 31 - 34 35 - 36 37 - 40 41 - 189 190 - 193 194 195 - 197 ..........
PDL Identifier ((0001)) PDL Page Format Revision Vendor Identification (MSB – LSB) (ASCII) Product Identification (MSB – LSB) (ASCII) Product Revision Level (MSB – LSB) (ASCII) Drive Serial Number (MSB – LSB) PDL Page Number (MSB – LSB) Number of Defective Sectors (MSB – LSB) Unspecified st 1 Defective Sector (MSB – LSB) (PBA) st 1 Defective Sector Defect Cause st 1 Defective Sector Drive Serial Number (MSB – LSB) ...........
8182 - 8185 8186 8187 - 8189 8190 - 8191
1000 Defective Sector (MSB - LSB) (PBA) th 1000 Defective Sector Defect Cause th 1000 Defective Sector Drive Serial Number (MSB – LSB) PDL Identifier Complement ((FFFE))
th
The PDL Format Revision, Vendor Identification, Product Identification, Product Revision, and Drive Serial Number fields shall contain implementation specific information that shall be ignored for the purposes of interchange. The PDL Format Revision is used to specify the format of the unspecified bytes in the PDL Page. When writing a PDL Page, the control record LBA shall be set to the PBA + (80000000).
19.6
Secondary Defect List (SDL) format and content The SDL is used to record the addresses of data and spare sectors, which have become defective after initialization and those of their respective replacements. The SDL shall consist of bytes specifying -
the format revision of the SDL Page,
-
information about the drive type that wrote the SDL Page,
-
a SDL Page sequence number,
-
the number of entries in the SDL Page,
-
the PBAs of the first sector in the SSA that is covered by the SDL Page,
-
the PBA of each defective sector,
-
a vendor unique defect code for each defective sector,
-
the drive serial number of the drive that found each defective sector,
-
the PBA of the first write attempt to the Page,
-
the count of the number of times the Page has been updated (set to ZERO for Type WORM media).
Table 24 shows the PDL byte layout. All unused defect entries in an SDL Page shall have the PBA set to (7FFFFFFF), the Defect Cause set to (FF), and the Drive Serial Number set to (FFFFFF). Defective SSA sectors shall be recorded in the SDL Page in the same manner as unused sectors.
- 70 -
T able 24 – Sec ondary Def ec t Lis t Page f or m at Byte
Contents
0-1 2 3 - 10 11 - 26 27 - 30 31 - 34 35 - 36 37 - 38 39 - 42 43 - 46 47 - 48 49 - 189 190 - 193 194 195 - 197 ..........
SDL Identifier ((0002)) SDL Page Format Revision Vendor Identification (MSB – LSB) (ASCII) Product Identification (MSB – LSB) (ASCII) Product Revision Level (MSB – LSB) (ASCII) Drive Serial Number (MSB – LSB) SDL Page Number (MSB – LSB) Number of PBAs in this Page (MSB – LSB) First Spare in this Page (MSB – LSB) (PBA) Page Origin PBA Page Update Count Unspecified 1st Defective Sector (MSB – LSB) (PBA) 1st Defective Sector Defect Cause 1st Defective Sector Drive Serial Number (MSB – LSB) ...........
8182 - 8185 8186 8187 - 8189 8190 - 8191
1000th Defective Sector (MSB - LSB) (PBA) 1000th Defective Sector Defect Cause 1000th Defective Sector Drive Serial Number (MSB – LSB) SDL Identifier Complement ((FFFD))
The SDL Format Revision, Vendor Identification, Product Identification, Product Revision, and Drive Serial Number fields shall contain implementation specific information that is ignored for the purposes of interchange. The SDL Format Revision is used to specify the format of the unspecified bytes in the SDL Page. SDL Pages shall be generated in ascending order by the contents of the First Spare in this Page field. Entries in a given SDL Page shall be in ascending order by replacement PBA. The replacement PBA for a given defective PBA is computed by determining which defect entry contains the defective PBA and taking the index, starting at zero, of that entry and adding it to the contents of the First Spare in this Page field. Each SDL Page shall contain space for 1 000 defect entries, however the Maximum Entries Per SDL Page field in the DDS dictates the maximum number that may be used. This number may be different for media Type WORM and Type RW. On Type WORM Media, an SDL Page shall only be written when the number of defect entries is equal to the maximum specified in the DDS. The SDLDP Area shall contain a copy of each completed SDL Page. When writing an SDL Page, the control record LBA shall be set to the PBA + (80000000).
- 71 -
Section 4 - Characteristics of embossed information 20
Embossed information – Method of testing The format of the embossed information on the disk is defined in clauses 13 to 17. Clauses 21 and 22 specify the requirements for the signals from the grooves and Preformatted Headers, as obtained when using the Reference Drive specified in clause 9.
20.1
Environment All signals specified in clauses 21 and 22 shall be within their specified ranges with the cartridge in any environment in the range of allowed operating environments defined in 8.1.2.
20.2
Use of the Reference Drive All signals specified in clauses 21 and 22 shall be measured in the indicated channels of the Reference Drive. The drive shall have the following characteristics for the purpose of these tests.
20.2.1
O ptics and mechanics The focused optical beam shall have the properties defined in 9.2. The disk shall rotate as specified in 9.5.
20.2.2
Read po w er The read power shall be 500 VW ± 25 VW.
20.2.3
Read Channel The drive shall have a Read Channel, with the implementation as given in 9.3.
20.2.4
T rackin g During the measurement of the signals, the focus of the optical beam shall have an axial deviation of not more than e max (axial) = 0,3 Vm from the recording layer, and it shall have a radial deviation of not more than e max (radial) = 0,04 Vm from the centre of a Groove or a Land Recording Track.
20.2.5
20.3
Axial f o cu s o f f set o p t imiz at ion The axial focus offset shall be adjusted to maximize the peak-to-peak amplitude of the 4T mark and 4T space pattern from the AM fields as measured in the Read Channel. This axial focus offset adjustment shall be used during the measurement of all embossed signals.
Definition of signals Figure 27 shows the signals specified in clauses 21 and 22. All signals are linearly related to currents through a split photodiode detector, and are therefore linearly related to the optical power falling on the detector. Two signals I 1 and I 2 are derived from the outputs of the split photodiode detector H of the Reference Drive (see 9.1). The read signal I provided by the Read Channel is the high bandwidth sum signal I = (I 1 + I 2 ) as processed by the low-pass filter described in Annex L.
- 72 -
Beam in groove or on land
Grooved areas without embossed Headers I1 + I2
(I 1 + I 2 ) max
(I 1 + I 2 ) min I1 – I2
0 Level
Figure 27a – Signals from grooves and lands in the Radial Tracking Channel
TA
AM, ID
QWML
QWMG
I q adj I q trk
… I IG or I OL
I p min
I p max
… I q dif
I top
0 Level Figure 27b – Signals from Headers in the Read Channel Figure 27 – Illustration of the various parameters for embossed signal characteristics
21
Signals from grooves and lands The sum signal (I 1 + I 2 ) and difference signal (I 1 – I 2 ) considered in this clause (see figure 27a) th shall be filtered using a 5 order Bessel filter with a cut-off frequency of 1,0 MHz such that frequencies above the cut-off are attenuated, thereby eliminating the effect of modulation due to embossed Headers.
21.1
Ratio of groove to land signal The on-track signal in groove I IG or on land I OL is the sum signal (I 1 + I 2 ) in the Read Channel when the light beam is following a groove or a land in the Formatted Zone. The on-track signals shall meet the following requirement:
- 73 -
In the case of type WORM Media I IG
1,0
1,25
I OL In the case of type RW media I IG
0,85
1,15
I OL when measured in unrecorded areas.
21.2
Ratio of groove/land to Mirror Area signal The on-track signals shall also meet the following requirements: In the case of type WORM Media
0, 60
I IG
0,90
I MA 0,60
I OL
0,90
I MA In the case of type RW media 0,70
I IG
1,0
I MA 0,70
I OL
1,0
I MA where I IG and I OL are measured in an unrecorded area, and I MA is the sum signal measured in a Mirror Area.
21.3
Divided push-pull signal The divided push-pull signal is the peak-to-peak amplitude derived from the instantaneous level of the differential output (I 1 - I 2 ) divided by the instantaneous level of the sum output (I 1 + I 2 ) when the focused light beam crosses unrecorded fields of grooved tracks. The radial tracking servo shall be operating in an open-loop mode during this measurement. The divided push-pull signal shall meet the following requirement: 0,70
(I 1 - I 2 )
1,40
(I 1 + I 2 ) PP
21.4
Wobble signal The wobble signal is the signal generated by the square wave shaped displacement of the groove as measured in the Tracking Channel when the focus of the beam is following a groove or a land in the unwritten recording fields of the Formatted Zone as specified in 20.2.4.
- 74 -
The wobble signal shall satisfy the three following requirements: 0,05
Wobble PP (I 1 - I 2 ) PP
0,10
where Wobble PP is the wobble signal peak-to-peak amplitude for both the groove and land tracks, and (I 1 - I 2 ) PP is the push pull signal peak-to-peak amplitude when the light beam crosses tracks in unwritten recording fields. In the case of type WORM media NBSNR
35 dB (in a 10 kHz bandwidth)
In the case of type RW media NBSNR
34 dB (in a 10 kHz bandwidth)
where NBSNR is the Narrow-Band Signal-to-Noise Ratio of the wobble signal for both groove and land unwritten and written tracks. A(2F0) - 30 dB A(F0) where A(2F 0 ) and A(F 0 ) are respectively the amplitudes of the second harmonic 2F 0 and the fundamental frequency F 0 of the wobble, measured in a resolution bandwidth of 10 KHz.
21.5
Phase depth The phase depth of the grooves equals n×d
× 360° O where n is the index of refraction of the cover layer, d is the groove depth, and O is the wavelength of the laser. The phase depth shall be less than 90°.
21.6
Track location The Recording Track centres shall be located using the Quadrature Wobble Marks for both groove and land tracks (see 15.4 and Annex X).
22
Signals from Headers The signal obtained from the embossed Headers (see figure 27b) shall be measured in the Read Channel of the Reference Drive and processed with the low-pass filter described in Annex L.
22.1
Reference reflectance I t o p The reference reflectance signal I top , corresponding to the peak level of the on-track Quadrature Wobble Mark, shall meet the following requirement: In the case of type WORM Media I top
0,70
I MA In the case of type RW Media
0,80
I top I MA
- 75 -
22.2
Address Mark and ID signals The signal I p from the marks in the Address Mark and ID fields shall meet the requirements: In the case of type WORM media I p max 0,30
0,60 I top I p min 0,40 I p max
In the case of type RW media I p max 0,20
0,60 I top I p min 0,30 I p max
where I p min and I p max are the signals with the minimum and maximum amplitude in the AM and ID fields. The second requirement shall apply over any Header.
22.3
QWM signals The signal I q trk is the read signal from the QWM field positioned in line with the Recording Track. I q trk is associated with the QWMG field when tracking in the groove or the QWML field when tracking on the land. The signal I q trk shall meet the following requirement: In the case of type WORM media I q trk 0,30
I top
0,70
In the case of type RW media I q trk 0,12
I top
0,30
The signal I q adj is from the QWM (A and B sub-fields) of the two adjacent Recording Tracks. I q adj is associated with the QWML field when tracking in the groove or the QWMG field when tracking on the land. The signal I q adj shall meet the following requirement: In the case of type WORM media I q adj I q trk
0,15
- 76 -
In the case of type RW media I q adj 0,10 I q trk The signal I q dif is the difference in amplitude from the QWM (A and B sub-fields) of the two adjacent Recording Tracks. I q dif is associated with the QWML field when tracking on the groove or the QWMG field when tracking on the land. The signal I q dif shall meet the following requirement: | I q dif | 0,10 I q adj This requirement applies to any Header under the condition that the tracking offset has been adjusted so that average value of I q dif is equal to zero for the Recording Track.
22.4
Timing mean and jitter The Header signal shall be read and detected using the Read Channel circuit defined in Annex L under the conditions specified in 20.2. The timing mean Mt(H) and timing jitter Jt(H) shall be measured according to the procedure in Annex M and shall meet the following requirement: | Mt(H) – nT | + 5 Jt(H)
1,0 T
where T is the Channel clock period, Mt(H) is the mean (average), and Jt(H) is the standard deviation (sigma) of the separately measured time intervals of leading-to-trailing and trailing-toleading edges of the read signal. The ideal time interval corresponds to nT. Mt(H) and Jt(H) are illustrated in figure M.1 of Annex M. All the time interval samples detected from the Header signals shall satisfy the condition of Mt(H) and Jt(H).
- 77 -
Section 5 - Characteristics of the recording layer 23
Method of testing Clauses 24 to 26 describe a series of tests to assess the thermal-optical properties of the recording layer, as used for writing, rewriting, and erasing data. The tests shall be performed only in the Data field of the sectors. The write, rewrite, read, and erase operations necessary for the tests shall be made on the same Reference Drive. Clauses 24 to 26 specify only the average quality of the recording layer. Local deviations from the specified values, called defects, can cause write or erase problems. These defects are covered in section 6.
23.1
Environment All signals in clauses 24 to 26 shall be within their specified ranges with the cartridge in any environment in the range of allowed operating environments defined in 8.1.2 except where otherwise noted.
23.2
Reference Drive The write, rewrite, and erase tests described in clauses 24 to 26 shall be measured in the Read Channel of the Reference Drive. The drive shall have the following characteristics for the purpose of these tests.
23.2.1
O ptics and mechanics The focused optical beam shall have the properties defined in 9.2. The disk shall rotate as specified in 9.5.
23.2.2
Read po w er The read power shall be 500 VW ± 25 VW.
23.2.3
Read Channel The Reference Drive shall have a Read Channel that can detect the Phase Change marks in the recording layer. This Channel shall have an implementation equivalent to that given in 9.3. The edge positions in time shall be measured for testing purposes by a threshold detection method. The threshold value is referenced to the centre of the peak-to-peak envelope of the read signal. The positive peak and negative peak signals of the envelope circuit (see Annex N) shall each contain a single pole filter with a –3 dB rolloff point at 50 kHz.
23.2.4
T rackin g During the measurement of the signals, the focus of the optical beam shall have an axial deviation of not more than e max (axial) = 0,3 Vm from the recording layer, and it shall have a radial deviation of not more than e max (radial) = 0,04 Vm from the centre of a Groove or a Land Recording Track.
23.2.5
Sig nal d et ect ion f or t est in g p u rp oses The signal from the Read Channel is not equalized before detection. The signal shall be rolled th off with a 5 order Bessel low-pass filter with a cut-off frequency of half the Channel clock frequency of the band being tested (see Annex L). Nominally, the threshold value will be constant if the laser power calibration is perfect and there are no parameter variations. However, in some measurements the threshold value may have to be adjusted to minimize the effects of mark size changes due to parameter variations during writing.
- 78 -
23.3 23.3.1
Write conditions W rit e pulse and pow er w av ef orm For Type RW and Type WORM media, marks are recorded on the disk by pulses of optical power (see Annex O) at the test rotational frequency. The pulse shape for the purpose of testing shall be nominally rectangular. The rise and fall times (10 % to 90 % or 90 % to 10 %) shall be less than 1,0 ns between any two sequential power levels. The measurement of laser power shall be done in pulsed operation by averaging. For example, use one pulse every 20 ns with a fixed duty cycle while measuring with a spherical radiometer. The averaging method of measuring the laser power will minimize the accumulation of pulse width and pulse amplitude tolerances. Pulsed operation also enables evaluation of higher laser powers than allowed by the continuous power rating of the laser (see also Annex CC). The values of P FW , P MP , P LW , P ER , P CL , and P B used in any media tests shall be the ones recorded in the SDI sectors for that particular piece of media (see 17.4.4). Values of laser power levels (or ratio of powers) required for groove or land recording in each band shall be recorded in the SDI sectors. The values of pulse timing parameters T SFP , T EFP , T X1 , T X3 , T SMP , T X2 , T EMP , T EMPP , T SLP , T ELP , T ECP , with the required adaptive timing adjustments corresponding to the previous mark or space lengths (see table K.2 of Annex K) shall also be recorded in the SDI sectors. The write pulse power and pulse widths are determined using the method in 23.3.4. Mark and space lengths of 2T to 9T shall be used in all media tests to evaluate the recording laser power levels and write pulse timing.
23.3.2
W rit e pulse pow er The media manufacturer shall determine the value of the pulse power levels P FW , P MP , P LW , P ER , P CL , and P B that are recorded in the SDI sectors. The nominal write first pulse power level P FW for groove or land recording in each band at the test rotational speed shall be recorded in the SDI sectors. The remaining power levels are specified as a ratio to the write first pulse level P FW for groove or land recording for each band. The average power during writing for any disk at any radius shall not exceed 3,75 mW as measured over a 10 Vs time interval. The maximum pulse power level used for recording on any disk at any radius shall not exceed 8,0 mW.
23.3.3
W rit e pulse timing The media manufacturer shall determine the value of the pulse timing parameters T SFP , T EFP , T X1 , T X3 , T SMP , T X2 , T EMP , T EMPP , T SLP , T ELP , T ECP , and the required adaptive timing adjustments corresponding to the previous mark or space lengths that are recorded in the SDI sectors. The write pulse timing parameters for each band at the test rotational speed shall be recorded in the SDI sectors.
23.3.4
W rit e p ulse po w er an d pu lse t imin g d et ermin at io n The media manufacturer shall determine the value of the write pulse power levels and pulse timing parameters using the following method: -
Write several Groove and Land Recording Tracks with the test patterns described in Annex N. The recordings shall be done at a media temperature of 25 °C ± 2 °C and at the test rotational frequency.
-
Read and detect the readback signal with the detection method given in Annex L. Adjust focus for maximum readback signal using the 3T mark and 3T space pattern of VFO1 and set the threshold at 50 % of the peak-to-peak signal amplitude for this test.
- 79 -
-
Measure the time intervals between edges using a TIA as described in Annex M. Adjust the write pulse power levels and pulse timing parameters to minimize the timing mean Mt and timing jitter Jt for each mark and space length from 2T to 9T. Adjusting the pulse power levels and pulse timing parameters is a multi-variable iterative process. The media manufacturer may use any optimization algorithm that minimizes both Mt and Jt, within the optical power constraints of 23.3.2 and 23.4.
-
The process shall be repeated for Groove and Land Recording Tracks in each band on the disk.
The write parameters recorded in the SDI sectors shall generate written data that complies with the requirements of clause 25 for Groove and Land Recording Tracks in all bands.
23.4
Erase pow er for Type RW media For Type RW media, marks can be erased from the disk by a constant optical power. The erase optical power P ER is also used between write pulses for direct overwriting of the recording field. The erase power is the optical power required for any given track at the entrance surface to erase or direct overwrite marks written according to 23.3. The ratio of erase power level P ER to the write first pulse level P FW for groove or land recording is recorded in the SDI sectors for each band at the test rotational speed (see 17.4.4). The erase power for any disk at any radius shall not exceed 3,75 mW.
23.5
Read pow er damage Recorded data shall not become damaged due to the repetitive reading of sectors. Media shall be tested against read power damage for Groove and Land Recording Tracks in the innermost band at the test rotational speed. Media shall be tested for read power damage as follows:
24 24.1
-
Several sectors shall be written on the Groove and Land Recording Tracks of the innermost band according to 23.3. Sectors shall be selected which are verified as correctable with less than 10 byte errors per sector using the ECC as defined in Annex H.
-
The read power shall then be increased to 600 VW ± 25 VW. The disk shall make 1 000 000 revolutions while remaining on a single Recording Track which contains the selected sectors.
-
After all test revolutions have completed, the read power shall be returned to the nominal power level. All selected sectors shall be verified as correctable with less than 100 byte errors per sector.
-
This test shall be preformed for both Groove and Land Recording Tracks.
Phase Change characteristics Mark polarity The Phase Change marks shall be either more or less reflective than spaces. The polarity of Phase Change marks shall be specified by the manufacturer in byte 40 of the SDI sectors (see 17.4.4).
24.2
Rew rite cycles for Type RW media The number of rewrite cycles for Type RW media is not specified by this Ecma Standard.
- 80 -
25 25.1
Write characteristics Resolution I L is the peak-to-peak value of the signal obtained in the Read Channel from 9T marks and 9T spaces (see figure 29) written under any of the conditions given in 23.3, and read under the conditions specified in 23.2. A 9T is the longest interval allowed in the recording field of a sector. I H is the peak-to-peak value of the signal obtained in the Read Channel from 2T marks and 2T spaces (see figure 28) written under any of the conditions given in 23.3, and read under the conditions specified in 23.2. A 2T is the shortest interval allowed by the RLL(1,7) code in the recording field of a sector. The resolution I H / I L shall not be less than 0,10 within any sector.
9T marks and spaces
2T marks and spaces
9T marks and spaces
IL
IH
Figure 28 – Definition of IL and IH for resolution measurement
25.2
Narrow -Band Signal-to-Noise Ratio (NBSNR) The Narrow-Band Signal-to-Noise Ratio NBSNR is the ratio of the signal level to the noise level of a specified pattern, measured in a 30 kHz bandwidth. It shall be determined as follows. -
Write a series of 2T marks followed by 2T spaces in the Data field of a series of sectors at a frequency f 0 of the highest frequency allowed by the RLL(1,7) code for each zone. The write conditions shall be as specified in 23.3.
-
Read the recording fields with the Read Channel under the conditions specified in 23.2 using a spectrum analyzer with bandwidth of 30 kHz. Measure the amplitudes of the signal and noise at frequency f 0 indicated in figure 30. The measurements shall be corrected for the effect of the Header fields and for any instrumentation error in order to obtain the Data field only.
The Narrow-Band Signal-to-Noise Ratio shall be NBSNR = 20 log 10
Signal level Noise level
The NBSNR shall be greater than 43 dB for all sectors in the RW or 40 dB for all sectors in the WORM zones using the optical system as defined in 9.1.
- 81 -
Amplitude Signal level
Noise level
Frequency f0 Figure 29 – Amplitude versus frequency for the Phase Change signal
25.3
Cross-talk ratio The cross-talk from nT marks and spaces shall be measured as follow: -
Write a series of nT marks followed by nT spaces in the Data field of the sectors on Recording Track n at the frequency specified for each band in the Formatted Zone. The write conditions shall be as specified in 23.3.
-
Read the recording fields of the sectors in Recording Track n-1, n, and n+1 under the conditions specified in 23.2.
The cross-talk from track n to n-1 and from track n to n+1 for 2T marks and 2T spaces and 9T marks and 9T spaces measured as the ratio in dB of the read signal of these tracks shall be lower than – 26 dB for type RW media and –23 dB for type WORM media.
25.4
Timing mean The timing mean Mt(nT) of nT marks and spaces is defined as the mean (average) of the separately measured time intervals of leading-to-trailing and trailing-to-leading edges of the read signal. The ideal time interval is nT where T is the Channel clock period. The data shall be written in accordance with 23.3 and the procedures described in Annex N. The signal shall be read and detected using the Read Channel circuit defined in Annex L under the conditions specified in 23.2. The timing mean Mt shall be measured according to the procedure in Annex M.
25.4.1
T iming mean for 2T marks and spaces The timing mean for 2T marks and spaces shall meet the following requirement in the Formatted Zone: – 0,20 T
25.4.2
Mt(2T) – 2T
+ 0,20 T
T imin g mean f o r n = 3T t o 9T , marks and spaces The timing mean for n = 3T to 9T, marks and spaces shall meet the following requirement in the Formatted Zone: – 0,15 T
Mt(nT) – nT
+ 0,15 T
- 82 -
25.5
Timing jitter The timing jitter Jt is defined as the standard deviation (sigma) of the separately measured time intervals of leading-to-trailing and trailing-to-leading edges of the read signal. The data shall be written in accordance with 23.3 and the procedures described in Annex N. The signal shall be read and detected using the Read Channel circuit defined in Annex L under the conditions specified in 23.2. The timing jitter Jt shall be measured according to the procedure in Annex M.
25.5.1
T iming jit t er for 2T marks and spaces The timing jitter for 2T marks and spaces shall meet the following requirement in the Formatted Zone: Jt (2T)
25.5.2
0,20 T
T iming jit t er for 3T to 9T marks and spaces The timing jitter for 3T to 9T marks and spaces shall meet the following requirement in the Formatted Zone: Jt (3T to 9T)
25.6
0,15 T
Asymmetry The asymmetry (see Annex P) of the user written marks relates to the deviation of the centre levels of the signals generated by two distinct repeating mark and space length patterns.
25.6.1
Asymmet ry ( 3T - 2T ) For type WORM media the asymmetry (3T-2T) in a sector shall be in the range – 0,25 to + 0,10. For type RW media the asymmetry (3T-2T) in a sector shall be in the range – 0,20 to + 0,20.
25.6.2
Asymmet ry ( 9T - 3T ) For type WORM media the asymmetry (9T-3T) in a sector shall be in the range – 0,0 to + 0,25. For type RW media the asymmetry (9T-3T) in a sector shall be in the range – 0,18 to + 0,15.
26
Erase power determination for Type RW media Erase power determination is critical for maximizing the rewrite cycle life of Type RW media. Excessive erase power levels can damage the recording layer, and thereby reduce the rewrite cycle life. The media manufacturer shall determine the erase to write power ratios that are recorded in the SDI sectors. The erase power is the optical power level for the given radius and rotational speed that is sufficient to erase or direct overwrite the current track, without damaging the recording layer or erasing data on the adjacent tracks. The media manufacturer shall perform direct overwrite cycle testing at varying erase powers to determine the power level that maximizes the number of rewrite cycles. The resulting optimal erase power level must comply with all requirements of clause 25, and also meet the requirement of 26.1 for cross-erase. This procedure shall be repeated to determine the erase to write power ratio for both Groove and Land Recording Tracks for each band of the disk.
26.1
Cross-Erase for Type RW Media The following procedure shall be used to determine the effect of erasing and direct overwriting Recording Tracks that are adjacent to previously recorded data on Type RW media:
- 83 -
A. Select any group of three adjacent tracks n-1, n, and n+1 in the Formatted Zone: -
Erase Recording Tracks n-1 and n+1 using the erase power determined in clause 26.
-
Write a series of 2T marks followed by 2T spaces in the Data field of the sectors on Recording Track n at the frequency specified for each band in the Formatted Zone. The write conditions shall be as specified in 23.3 (see also Annex CC).
-
Measure the initial NBSNR on track n as specified in 25.2.
B. Using a radial tracking offset equal to zero: -
Write the Data fields of track n-1 and track n+1 with a series of 2T marks followed by 2T spaces.
-
Write the Data fields of track n-1 and track n+1 with a series of 9T marks followed by 9T spaces.
-
Erase the Data fields of track n-1 and track n+1.
C. Adjust the radial tracking offset by 40 nm toward the outer diameter of the disk: -
Write the Data fields of track n-1 and track n+1 with a series of 2T marks followed by 2T spaces.
-
Write the Data fields of track n-1 and track n+1 with a series of 9T marks followed by 9T spaces.
-
Erase the Data fields of track n-1 and track n+1.
D. Adjust the radial tracking offset by 40 nm toward the inner diameter of the disk: -
Write the Data fields of track n-1 and track n+1 with a series of 2T marks followed by 2T spaces.
-
Write the Data fields of track n-1 and track n+1 with a series of 9T marks followed by 9T spaces.
-
Erase the Data fields of track n-1 and track n+1.
E. Repeat steps B, C, and D on track n-1 and track n+1 for 10 complete cycles. F. Using a radial tracking offset equal to zero, measure the final NBSNR on track n. For the specified cross-erase test conditions, the change in NBSNR of track n shall be NBSNR inital – NBSNR final < 1,0 dB
- 84 -
Section 6 - Characteristics of user data 27
User Data – Method of testing Clauses 28 and 29 describe a series of measurements to test conformance of the user data on the disk with this Ecma Standard. It checks the legibility of both Preformatted Header and user written data. The user written data is assumed to be arbitrary. The user written data may have been written by any drive in any environment. The read tests shall be performed on the Reference Drive. Whereas defects are disregarded in clauses 20 to 26, they are included in clauses 28 and 29 as unavoidable deterioration of the read signal. The severity of a defect is determined by the correctability of the ensuing errors by the error detection and correction circuits in the Read Channel defined below. The requirements in clauses 28 and 29 define a minimum quality of the data, necessary for data interchange.
27.1
Environment All signals specified in clauses 28 and 29 shall be within their specified ranges with the cartridge in any environment in the range of allowed operating environments defined in 8.1.2. It is recommended that before testing, the entrance surface of the optical disk shall be cleaned according to the instructions of the manufacturer of the disk.
27.2
Reference Drive All signals specified in clauses 28 and 29 shall be measured in the Reference Drive. The drive shall have the following characteristics for the purpose of these tests:
27.2.1
O ptics and mechanics The focused optical beam shall have the properties specified in 9.2. The disk shall rotate as specified in 9.5.
27.2.2
Read pow er The read power shall be 500 VW ± 25 VW.
27.2.3
Read Channel The Read Channel shall be as specified in 9.3 and Annex L.
27.2.4
M ark qualit y The signal in the Read Channel shall be processed (see Annex L) with the specified low-pass filter and equalization, and compared with the threshold follower level. The threshold level shall be adjusted to minimize the bias of the mark and space intervals from their desired (or ideal) values of 2T, 3T, … 9T. The output signals from the comparator are converted to binary signals with the edge detector (see also Annex N). The timing jitter in this section is defined as the standard deviation (sigma) of the separately measured time intervals of leading-to-trailing and trailing-to-leading edges excluding outlying observations caused by defects. The measurement is made using a TIA with the output signals from the edge detectors of the marks and spaces in a sector. Therefore, the number of marks and spaces in a sector limits the independent interval samples for this measurement. The timing jitter values shall be expressed as a percentage of the Channel bit time T. The converter shall operate correctly for analog signals from embossed marks with signal characteristics as determined by clause 22. The converter shall operate correctly for analog signals from user written marks with signal characteristics as determined by clause 25.
- 85 -
27.2.5
Channel bit clock The Channel bit clock shall be virtually locked to the signals from the analog-to-binary converters during reading to provide a time base for the leading and/or the trailing edges of the binary signals. During reading, the Channel bit clock shall be adjusted in order to minimize the accumulated value of timing errors of the leading-to-trailing and trailing-to-leading edges from the Channel bit clock. The Channel bit clock shall be virtually locked to the wobble groove signal during writing, rewriting, and erasing to provide a time base for the write pulse generator. During writing, rewriting, or erasing, the Channel bit clock shall be adjusted in order to minimize the accumulated value of timing error from the groove wobble period and 240 Channel bit clock periods (240 T).
27.2.6
Binary- t o- digit al conv ert ers The binary signals shall be correctly converted to the data bytes with the binary-to-digital converters based on the sector format and recording code defined in clauses 15 and 16. The 2T marks and 2T spaces in the recording area shall be detected using the ESISIC algorithm described in Annex Q.
27.2.7
Erro r co rrect ion Correction of errors in the data bytes shall be carried out by an error detection and correction system based on the definition in H.2 and H.3 of Annex H.
27.2.8
T rackin g During the measurement of the signals, the focus of the optical beam shall have an axial deviation of not more than e max (axial) = 0,3 Vm from the recording layer, and it shall have a radial deviation of not more than e max (radial) = 0,04 Vm from the centre of a Groove or a Land Recording Track.
28
Minimum quality of a sector This clause specifies the minimum quality of the Header and Data fields of a sector as required for interchange of the data contained in that sector. The quality shall be measured on the Reference Drive specified in 27.2. A byte error occurs when one or more bits in a byte have a wrong setting, as detected by ECC and/or CRC circuits.
28.1
Headers ID At least one of the three ID fields contained in the Preformatted Headers shall not have any byte errors as checked by the CRC in the field. Sectors shall only be recorded with user data under this condition. Sectors shall be readable under the condition that all three of the ID fields have byte errors as checked by CRC.
28.2 28.2.1
User-w ritten data Reco rding f ield When the VFO1 field is recorded, it shall start at 508 Channel bits – 6/+ 133 Channel bits from the end of the Preformatted Header for Type RW media. When the VFO1 field is recorded, it shall start at 396 Channel bits ± 6 Channel bits from the end of the Preformatted Header for Type WORM media.
- 86 -
28.2.2
Byt e errors The user written data in a sector shall not contain any byte errors that cannot be corrected by the error correction defined in 27.2.7.
28.2.3
T iming mean The timing mean of the user written marks shall comply with the requirements of 25.4.
28.2.4
T iming jit t er The timing jitter of the user written marks shall comply with the requirements of 25.5.
28.2.5
Asymmet ry The asymmetry of the user written marks shall comply with the requirements of 25.6.
28.3
Wobble signal The wobble signal shall comply with the requirements of 21.5.
29
Data interchange requirements A disk offered for interchange of data shall comply with the following requirements (see also Annex R).
29.1
Tracking The focus of the optical beam shall not jump tracks unintentionally.
29.2
User-w ritten data Any sector written in the User Zone that does not comply with 28.2 shall have been replaced according to the rules of the Defect Management as defined in clause 19.
29.3
Quality of disk The quality of the disk is reflected in the number of replaced sectors in the User Zone. This Ecma Standard allows a maximum number of replaced sectors per side (see clause 19).
- 87 -
- 88 -
Annex A (normative) Air cleanliness class 100 000 The classification of air cleanliness is based on a particle count with a maximum allowable number of specified minimum sized particles per unit volume, and on a statistical average particle size distribution.
A.1 Definition The particle count shall not exceed a total of 3 500 000 particles per cubic metre of a size 0,5 Vm and larger. The statistical average particle size distribution is given in figure A.1. Class 100 000 means that 3 500 000 particles per cubic metre of a size of 0,5 Vm and larger are allowed, but only 25 000 particles per cubic metre of a size of 5,0 Vm and larger. It shall be recognized that single sample distribution may deviate from this curve because of local or temporary conditions. Counts below 350 000 particles per cubic metre are unreliable except when a large number of samplings is taken.
A.2 Test method For particles of size in the range of 0,5 Vm to 5,0 Vm, equipment employing light-scattering principles shall be used. The air in the controlled environment is sampled at a known flow rate. Particles contained in the sampled air are passed through an illuminated sensing zone in the optical chamber of the instrument. Light scattered by individual particles is received by a photo detector which converts the light pulses into electrical current pulses. An electronic system relates the pulse height to particle size and counts the pulses such that the number of particles in relation to particle size is registered or displayed.
- 89 -
Number of particles per m greater than or equal to the stated particle size
3
100 000 000 10 000 000 1 000 000 100 000
10 000
1 000 100 0,1
0,5 1
5 10 100 Particle size (Vm)
Figure A.1 - Particle size distribution curve
- 90 -
1 000
Annex B (normative) Edge distortion test
B.1 Purpose The distortion test checks if the case is free from unacceptable distortion and protrusions along its edges. The test is made by causing the cartridge to pass through the vertical slot of a gauge while applying a specified force in addition to the gravitational pull.
B.2 Distortion gauge construction The gauge shall be made of a suitable material, e.g. of chrome-plated carbon steel. The inner surfaces shall be polished to a surface finish of 5 Vm peak-to-peak.
B.3 Distortion gauge dimensions The dimensions shall be as follows (see figure B.1): A = 155,0 mm B = 136,0 mm ± 0,1 mm C = 10,0 mm ± 0,1 mm D = 11,40 mm ± 0,01 mm E = 11,60 mm min.
B.4 Requirement When the cartridge is inserted vertically into the gauge, a vertical downward force F of 2,7 N maximum, applied to the centre of the top edge of the cartridge, shall cause the cartridge to pass through the gauge.
- 91 -
F
D
A C B
C
D E
03-0019-A
Figure B.1 – Distortion gauge
- 92 -
Annex C (normative) Compliance test
C.1 Purpose The compliance test checks the flatness and flexibility of the case by forcing the four reference surfaces of the cartridge into a plane.
C.2 Reference surfaces The location of the four reference surfaces S1, S2, S3, and S4 is defined in 10.5.4 and figure 4.
C.3 Compliance gauge The test gauge consists of a base plate on which four posts P1, P2, P3, and P4 are fixed so as to correspond to the surfaces S1, S2, S3, and S4 respectively (see figure C.1). The dimensions are as follows (see figures C.2 and C.3): L a = 122,0 mm ± 0,2 mm L b = 4,0 mm ± 0,5 mm L c = 130,0 mm ± 0,5 mm L d = 101,0 mm ± 0,5 mm D a = 6,50 mm ± 0,01 mm + 0,00 mm
D b = 4,00 mm
- 0,02 mm
D c = 5,50 mm ± 0,01 mm H a = 1,0 mm ± 0,1 mm H b = 2,0 mm max. After assembly, the upper annular surfaces of the four posts shall lie between two horizontal planes spaced 0,01 mm apart.
C.4 Test conditions The cartridge shall be placed with its reference surfaces onto the posts of the horizontal gauge. A vertical down force F of 0,4 N shall be exerted on the cartridge opposite each of the four posts.
C.5 Requirement Under the conditions of C.4, any three of the four surfaces S1 to S4 shall be in contact with the annular surface of respective posts. Any gap between the remaining surface S and the annular surface of its post shall not exceed 0,1 mm.
- 93 -
F
F F
F
P2
P4 P1
P3
03-0021-A
Figure C.1 – Compliance gauge
- 94 -
La
Lb
P2
P1
Ld
P4
P3
Lc
03-0023-A
Figure C.2 – Location of the posts
Db
Ha
Z
Dc
Da
P3, P4
P1, P2
03-0024-A
Figure C.3 – Detail of the posts
- 95 -
Hb
- 96 -
Annex D (normative) Cartridge electro-static discharge test
D.1 Test procedure The test procedure shall use the following steps: 1
Acclimate test cartridges at 10 % relative humidity for at least 12 hours before testing.
2
Remove all charge from the test cartridge using ionized air.
3
Mount the cartridge in the fixture shown in figure D.1.
4
Apply 1,00 kV to the charge plate.
5
10 seconds ± 1 second after applying 1,00 kV, remove the voltage source (charge plate is floating).
6
Measure the decay time defined as the time required for the charged plate voltage to decay 5 % to 950 V.
Prior to testing a cartridge, ensure there is a non-ionizing environment by performing steps 4 – 6 above with no cartridge present. Decay time with no cartridge shall be larger than 100 seconds.
D.2 Specification The decay time shall be smaller than 30 seconds at 10 % relative humidity and 25 °C.
Figure D.1 – Cartridge electro-static discharge test fixture
- 97 -
- 98 -
Annex E (normative) Test method for measuring the adsorbent force of the hub
E.1 Purpose The purpose of this test is to determine the magnetic characteristic of the magnetizable material of the hub.
E.2 Dimensions The test device (see figure E.1) consists of a spacer, a magnet, a back yoke, and a centre shaft. The dimensions of the test device are as follows: D d = 8,0 mm ± 0,1 mm D e = 20,0 mm ± 0,1 mm D f = 19,0 mm max. + 0,0 mm
D g = 3,9 mm
- 0,1 mm
H c = 0,40 mm ± 0,01 mm H d = 1,2 mm (typical, to be adjusted to meet the force requirement of E.4)
E.3 Material The material of the test device shall be: Magnet
: Any magnetizable material, typically Sm-Co
Back yoke
: Any suitable magnetizable material
Spacer
: Non-magnetizable material or air gap
Centre shaft
: Non-magnetizable material
E.4 Characteristics of the magnet with back yoke Number of poles
: 4 (typical)
Maximum energy product (BH max )
:175 kJ/m ± 16 kJ/m
3
3
The characteristics of the magnet with back yoke shall be adjusted so that with a pure nickel plate of the following dimensions (see figure E.2), and the adsorbent force of this plate at the point H c = 0,4 mm when spaced from the magnet surface shall be 9,5 N ± 0,6 N. D h = 7,0 mm ± 0,1 mm D j = 22,0 mm ± 0,1 mm H e = 2,0 mm ± 0,05 mm
- 99 -
E.5 Test condition for temperature This condition shall be as specified in 8.1.1.
Df Dg
Hub
Hc
Magnet Hd
Back yoke
Spacer Dd De
Centre shaft
03-0017-A
Figure E.1 – Test device for the clamping characteristic of the hub
Dh Dj 03-0014-A
Figure E.2 – Calibration plate of the test device
- 100 -
He
Annex F (normative) CRC for ID fields The sixteen bits of the CRC shall be computed over the first four bytes of the ID field. The generator polynomial shall be
G(x) = x 16 + x 12 + x 5 + 1 The residual polynomial shall be i = 31
R(x) =
(
i = 15 i
ai x + i = 16
ai x
i
)
x
16
mod G(x)
i=0
where a i denotes a bit of the first four bytes and a i an inverted bit. The highest order bit of the first byte is a 31. The sixteen bits c k of the CRC are defined by k = 15
R(x) =
ck x
k
k=0
where c 15 is recorded as the highest order bit of the fifth byte in the ID field and c 0 is the lowest order bit of the sixth byte in the ID field.
- 101 -
- 102 -
Annex G (normative) Data field scrambler implementation
G.1 Data field scrambler purpose The purpose of Data field scrambling is to randomize user data to generate various mark and space lengths in the encoded data. The data scrambler tends to reduce the d.c. content of the encoded data waveform. This is of primary importance for sectors with block of fixed data bytes. In these cases, without scrambling, the encoded data could consist of the same repeated patterns, which can generate a large d.c. content.
G.2 Data field scrambler order of processing The Data field shall be as detailed in Annex H. The entire Data field except for Resync, Reference, and VFO2 bytes shall be scrambled. The order of processing for encoding shall be 1 Interleave user data and Control bytes 2 Generate CRC and ECC bytes 3 Scramble bytes of the Data field 4 Insert Resync, Reference, and VFO2 bytes (not scrambled) The order of processing for decoding shall be the reverse of the encoding process 1 Remove Resync, Reference, and VFO2 bytes 2 Unscramble bytes of Data field 3 Perform ECC and check CRC 4 De-interleave user data and Control bytes
G.3 Data field scrambler circuit and preset values The scrambling byte generation circuit shall be as shown in figure G.1. The circuit consists of a feedback bit shift register in which bits r 7 (msb) to r 0 (lsb) are used as a scrambling byte at each 8-bit shift. The initial preset number, shown in table G.1 is equivalent to least significant 4 bits of the 31-bit PBA value, b3 to b0, in which b3 is the msb and b0 is the lsb. At the beginning of each Data field, the initial value of r14 to r0 shall be preset corresponding to the PBA of the sector as shown in table G.1 (the msb of the pre-set value shall be discarded). The initial value shall be changed every sector, and after 16 sectors, the sequence shall be repeated. The lower 8 bits of the initial values of r 7 to r 0 shall be taken out as scrambling byte S 1 . After that, the 8-bit shift shall be repeated for each scrambled byte of the Data field. As a result, scrambling bytes S 2 to S n shall be taken from the shift register at each 8-bit shift.
- 103 -
T able G .1 – Initial value of s hif t r egis ter
r14
r13
r12
Initial preset number
Initial register value
(0)
(0001)
(1)
(5500)
(2)
(0002)
(3)
(2A00)
(4)
(0004)
(5)
(5400)
(6)
(0008)
(7)
(2800)
(8)
(0010)
(9)
(5000)
(A)
(0020)
(B)
(2001)
(C)
(0040)
(D)
(4002)
(E)
(0080)
(F)
(0005)
r 11
r10
r9
r8
r7
r6
r5
r4
r3
Figure G.1 – Feedback shift register for generating the scrambling byte
Scrambling for data byte D k in figure G.1 is defined as follows: D’ k = D k
Sk
(k = 1 to n)
where D’ k is the scrambled data byte D k is an unscrambled data byte S k is the scrambling byte from the feedback shift register n is the number of data bytes to be scrambled in the Data field and
means Exclusive-OR logical operation.
- 104 -
r2
r1
r0
Annex H (normative) Interleave, CRC, ECC, Resync, and Reference for the Data field
H.1 Interleave The different bytes recorded on the disk for each sector with 8192 data-user bytes shall be designated as follows Dn
are user data bytes
P q,r are Control bytes (see 15.10.3) Ck
are CRC check bytes
E s,t are ECC check bytes These bytes shall be ordered in a sequence A n in the order in which they shall be recorded on the disk. The order of n of D n is the same as that in which they are input from the interface. Depending on the value of n, these elements are 8 192
: An = Dn
for 8 193
n
8 204
: A n = P q,r
for 8 205
n
8 208
: An = Ck
for 8 209
n
9 424
: A n = E s,t
for 1
n
where: q = int [(n – 8 193) / 4] + 1 r = [(n – 8 193) mod 4] + 1 k = n – 8 204 s = [(n – 8 209) mod 38] + 1 t = int [(n – 8 209) / 38] + 1 The notation int [x] denotes the largest integer not greater than x. The first four parts of A n are 38-way interleaved by mapping them onto a two-dimensional matrix B ij with 216 rows and 38 columns. Thus for 1
n
8 208
: B i,j = A n
where: i = 215 – int [(n – 1) / 38] j = (n – 1) mod 38
- 105 -
H.2 CRC The CRC and the ECC shall be computed over the Galois field based on the primitive polynomial 8
4
3
2
G P (x) = x + x + x + x + 1 The generator polynomial for the CRC bytes shall be i = 35
( x + ` i ) = x 4 + (68) x 3 + (69) x 2 + (F1) x + (DA)
G C (x) = i = 32
where the element ` = 0000 0010. The contents of the four check bytes are defined by the residual polynomial 4
RC (x) = I C (x) x mod G C (x) k= 4
RC (x) =
Ck x
4-k
k=1
The last equation specifies the storage locations for the coefficients of the polynomial.
H.2.1 Check byte calculation The four check bytes of CRC shall be computed over the user data and the control bytes as specified in H.2. The information polynomial shall be
I C (x) =
i = 215
[
(
i=1
j = 37
(Bi,j ) x i j=0
)] +
j = 33
(B0,j ) j=0
H.3 ECC The primitive polynomial G P (x) and the element polynomial for the check bytes of the ECC shall be
i
shall be as specified in H.2. The generator
i = 31
( x + `i )
G E (x) = i=0
where the element
= 0000 0010.
The 1216 check bytes of the ECC shall be computed over the user bytes, the control bytes, and the CRC bytes. The corresponding 38 information polynomials shall be i = 215
I Ej (x) =
(Bi,j ) x
i
i=0
where 0
j
37.
- 106 -
The contents of the 32 check bytes E s,t for each polynomial I Ej (x) are defined by the residual polynomial
REj (x) = I Ej (x) x
32
mod G E (x)
t = 32
REj (x) =
Ej+1,t x
32-t
t=1
The last equation specifies the storage locations for the coefficients of the polynomial.
H.4 Resync The Resync fields (see Annex J) shall be inserted in the Data field to prevent loss of synchronization and limit the propagation of errors in the user data. They are numbered consecutively and shall contain one of the two following patterns of Channel bits. 010 000 000 010 000 000 010 010
for RS1, RS3, RS5, …
010 000 000 010 000 000 010 000
for RS2, RS4, RS6, …
A field RSn shall be inserted between bytes A 152n and A 152n+1 , where 1
n
62.
RS62 shall be inserted immediately after byte A 9424 .
H.5 Reference The Reference fields (see Annex J) shall be inserted in the Data field to provide read signal reference levels. They are numbered consecutively and shall contain the following pattern of Channel bits. 010 010 010 010 A field RFn shall be inserted between bytes A 38n and A 38n+1 , where 0
n
248.
RF0 shall be inserted between the Sync field and byte A 1 . RF248 shall be inserted between RS62 and the PA field. The Reference byte shall be inserted after the Resync bytes whenever both are inserted between the same Data field bytes.
H.6 VFO2, Extra Sync (SBX), and Extra Reference (RFX) fields The VFO2, SBX, and RFX fields shall be inserted in the Data field to provide redundant fields in the event that the primary fields (VFO1, Sync, and RF0) are obscured or damaged. These three fields shall be inserted in the following order between bytes RF8 and A 305 : 1)
VFO2
2)
SBX
3)
RFX.
H.6.1 VFO2 The VFO2 field shall be inserted in the Data field to provide a redundant field for locking the VFO in the event that VFO1 is obscured or damaged. The VFO2 pattern shall be as defined in 15.8.
- 107 -
H.6.2 Extra Sync (SBX) The Extra Sync field shall be inserted in the Data field after VFO2 to provide a redundant field for synchronization in the event that the Sync field is obscured or damaged. The Extra Sync pattern shall be the same as the Sync field defined in 15.9.
H.6.3 Extra Reference (RFX) The Extra Reference field shall be inserted in the Data field after SBX to provide a redundant field for reference amplitude. The Extra Reference pattern shall be the same as the Reference field defined in H.5.
H.7 Recording sequence for Data field The elements of the Data field shall be recorded on the disk according to sequence A n immediately following the Sync bytes, with Resync bytes inserted as specified in H.4, Reference bytes inserted as specified in H.5, and VFO2, SBX, RFX bytes inserted as specified in H.6. Figure H.1 shows in matrix form the arrangement of these elements. The sequence of recording is from top-to-bottom and from left-to-right. SB designates a Sync byte D
designates a user byte
RS designates a Resync byte RF designates a Reference byte VF designates a VFO2 byte P
designates a Control byte
C
designates a check byte for CRC
E
designates a check byte for ECC
PA designates the PA byte Figure H.1 shows that the first 216 rows contain in columns 0 to 37, the user bytes, the Control bytes, and the CRC check bytes. The next 32 rows contain only ECC check bytes.
- 108 -
Row No. i Column No. j SB1
SB2
0 SB3
RS1,1
216 rows SBX1
SBX2
RS1,2
36
37
RF0
D1
...
...
D22
21
D23
22
D24
23
D25
24
D26
25
D27
26
D28
27
D29
28
D30
29
D31
30
D32
31
D33
32
D34
33
D35
34
D36
35
D37
D38
RF1
D39
...
D60
D61
D62
D63
D64
D65
D66
D67
D68
D69
D70
D71
D72
D73
D74
D75
D76
RF2
D77
...
D98
D99
D100
D101
D102
D103
D104
D105
D106
D107
D108
D109
D110
D111
D112
D113
D114
RF3
D115
...
D136
D137
D138
D139
D140
D141
D142
D143
D144
D145
D146
D147
D148
D149
D150
D151
D152
RF4
D153
...
D174
D175
D176
D177
D178
D179
D180
D181
D182
D183
D184
D185
D186
D187
D188
D189
D190
RF5
D191
...
D212
D213
D214
D215
D216
D217
D218
D219
D220
D221
D222
D223
D224
D225
D226
D227
D228
RF6
D229
...
D250
D251
D252
D253
D254
D255
D256
D257
D258
D259
D260
D261
D262
D263
D264
D265
D266
RF7
D267
...
D288
D289
D290
D291
D292
D293
D294
D295
D296
D297
D298
D299
D300
D301
D302
D303
D304
RS2,1
RS2,2
RF8
SBX3
SBX4
RFX
D305
...
D326
D327
D328
D329
D330
D331
D332
D333
D334
D335
D336
D337
D338
D339
D340
D341
D342
RF9
D343
...
D364
D365
D366
D367
D368
D369
D370
D371
D372
D373
D374
D375
D376
D377
D378
D379
D380
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
RS53,1
RS53,2
RF212
D8057
...
D8078
D8079
D8080
D8081
D8082
D8083
D8084
D8085
D8086
D8087
D8088
D8089
D8090
D8091
D8092
D8093
D8094
RF213
D8095
...
D8116
D8117
D8118
D8119
D8120
D8121
D8122
D8123
D8124
D8125
D8126
D8127
D8128
D8129
D8130
D8131
D8132
RF214
D8133
...
D8154
D8155
D8156
D8157
D8158
D8159
D8160
D8161
D8162
D8163
D8164
D8165
D8166
D8167
D8168
D8169
D8170
RF215
D8171
...
D8192
P1,1
P1,2
P1,3
P1,4
P2,1
P2,2
P2,3
P2,4
P3,1
P3,2
P3,3
P3,4
C1
C2
C3
C4
RF216
E1,1
...
E22,1
E23,1
E24,1
E25,1
E26,1
E27,1
E28,1
E29,1
E30,1
E31,1
E32,1
E33,1
E34,1
E35,1
E36,1
E37,1
E38,1
RF217
E1,2
...
E22,2
E23,2
E24,2
E25,2
E26,2
E27,2
E28,2
E29,2
E30,2
E31,2
E32,2
E33,2
E34,2
E35,2
E36,2
E37,2
E38,2
RS54,1
32 rows
SB4
RS54,2
VF1 through VF50
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
RS61,1
RS61,2
RF244
E1,29
...
E22,29
E23,29
E24,29
E25,29
E26,29
E27,29
E28,29
E29,29
E30,29
E31,29
E32,29
E33,29
E34,29
E35,29
E36,29
E37,29
E38,29
RF245
E1,30
...
E22,30
E23,30
E24,30
E25,30
E26,30
E27,30
E28,30
E29,30
E30,30
E31,30
E32,30
E33,30
E34,30
E35,30
E36,30
E37,30
E38,30
RF246
E1,31
...
E22,31
E23,31
E24,31
E25,31
E26,31
E27,31
E28,31
E29,31
E30,31
E31,31
E32,31
E33,31
E34,31
E35,31
E36,31
E37,31
E38,31
RF247
E1,32
...
E22,32
E23,32
E24,32
E25,32
E26,32
E27,32
E28,32
E29,32
E30,32
E31,32
E32,32
E33,32
E34,32
E35,32
E36,32
E37,32
E38,32
RF248
PA
RS62,1
RS62,2
** NOTE VFO2 bytes are not counted as a row of the data interleave Figure H.1 – Data configuration and ECC with interleave
- 109 -
215 214 213 212 211 210 209 208 ** 207 206 ... 3 2 1 0 -1 -2 ... -29 -30 -31 -32
- 110 -
Annex I (normative) Drive Information Record (DIR) usage The 4-byte Drive Information Record (P3) of the Control bytes shall be used to save drive related information into each sector as it is written or rewritten. For normally written sectors, the DIR shall contain the following information in the specified location: Byte 1 Bit position
7
6
5
4
Unspecified
Verify enabled
Verify Pass Relocation
7
6
5
3
2
1
0
1
0
Relocation cause
Byte 2 Bit position
Unspecified
4
3
Relocation Attempt
2
Drive Serial Number bits (19 – 16)
Byte 3 Bit position
7
6
5
4
3
2
1
0
2
1
0
Drive Serial Number bits (15 – 8)
Byte 4 Bit position
7
6
5
4
3
Drive Serial Number bits (7 – 0)
Unspecified bits shall be set to ZERO and shall be ignored in interchange. The Verify Enabled bit shall indicate whether the sector was written with Verify after Write enabled, as follows: Verify after Write disabled = ZERO Verify after Write enabled = ONE.
- 111 -
The Verify Pass Relocation bit shall be set to ZERO for all sectors that have not been relocated. The Verify Pass Relocation bit shall indicate whether a relocated sector was spared due to a Verify error, as follows: Write Error Relocation = ZERO Verify Error Relocation = ONE. The Relocation Cause field is vendor unique, and may be used to identify the reason for relocating the sector. The Relocation Cause field shall be ignored in interchange. The Relocation Attempt field shall be set to ZERO for all sectors that have not been relocated. The Relocation Attempt field shall contain the number of the relocation attempt for all relocated sectors as follows: Attempt 1 = 0 Attempt 2 = 1 ….................. Attempt 8 = 7 The Drive Serial Number is vendor unique and shall be ignored in interchange. For SDI, DDS, PDL, and SDL sectors, the Verify Pass Relocation, Relocation Cause, and Relocation Attempt fields shall be set to ZERO.
- 112 -
Annex J (normative) Determination of the Resync and Reference patterns
J.1 Conditions of Resync pattern The Resync pattern shall have the following characteristics to satisfy its required function: 1. The Resync patterns consist of irregular Channel bit patterns that do not occur in RLL(1,7) modulation code. 2. The irregularity of the Resync patterns is easily detectable. 3. There are two unique patterns, one for odd numbered Resync fields, and another for even numbered Resync fields. 4. The length of the Resync pattern shall be 24 Channel bits.
J.2 Resync pattern Selection of one of the two Resync patterns shown below shall be made in order to provide additional Data field synchronization information. The criteria for selecting either Resync Pattern 1 or Resync Pattern 2 is based on the position of the Resync fields within the data area.
Data
Resync pattern
Resync Pattern 1 (odd)
010 000 000 010 000 000 010 010
Resync Pattern 2 (even)
010 000 000 010 000 000 010 000
Reference byte
Resync Pattern 1 shall be used for all odd numbered Resync fields (RS1, RS3, RS5, …). Resync Pattern 2 shall be used for all even numbered Resync fields (RS2, RS4, RS6, …).
J.3 Conditions of Reference pattern The Reference pattern shall have the following characteristics to satisfy its required function: 1.
The Reference pattern is a Channel bit pattern consisting of either a 3T mark, 3Tspace, 3T mark or a 3T space, 3T mark, 3T space. The triple 3T patterns can be used for determining the read signal amplitude of 3T marks and spaces as a reference level for decoding of RLL(1,7) information.
2.
The read signal amplitude and shape of the reference pattern can be checked and used to locate possible data error positions for erasure ECC processing.
3.
The length of the Reference pattern shall be 12 Channel bits.
- 113 -
J.4 Reference pattern The Reference pattern shall be as follows. Sync, Resync, or Data 1
Reference pattern 010 010 010 010
- 114 -
Data 2
Annex K (normative) Specific Disk Information SDI sectors shall consist of 8 192 bytes that contain Specific Disk Information. These bytes shall specify the following. Bytes 0 and 1 These bytes shall be recorded with the SDI Identifier. Both bytes shall be recorded with (D1) to indicate that this is a SDI sector. Bytes 2 to 6 These five bytes shall contain the Disk Serial Number and Disk Side (A or B) (see table K.1). The Disk Serial Number shall be the same for both the A and B sides of the disk. The serial number and side of the disk shall be represented in hexadecimal notation. T able K.1 - Dis k Ser ial Num ber and Dis k Side bytes Byte
Description
Allowed values
7–4
st
1 digit of Disk Serial Number
(0) – (F)
2
3–0
nd
2 digit of Disk Serial Number
(0) – (F)
3
7–4
3 digit of Disk Serial Number
rd
(0) – (F)
3
3–0
4 digit of Disk Serial Number
th
(0) – (F)
4
7–4
5 digit of Disk Serial Number
th
(0) – (F)
4
3–0
6 digit of Disk Serial Number
th
(0) – (F)
th
(0) – (F)
th
(0) – (F)
th
2
5
Bits
7–4
7 digit of Disk Serial Number
5
3–0
8 digit of Disk Serial Number
6
7–4
9 digit of Disk Serial Number
(0) – (F)
6
3–0
Disk Side
(A) or (B)
Byte 7 This byte shall specify the SDI Revision number. The SDI Revision number may be used by the disk manufacturer to denote the use of the Unspecified SDI bytes. Bytes 8 to 15 These eight bytes shall contain the disk manufacturer code in ASCII representation. Byte 16 This byte shall specify the year of disk manufacture. It shall be specified as a number n such that n = year – 2000. Byte 17 This byte shall specify the month of disk manufacture. This byte shall be recorded with a value in the range from 1 (January) to 12 (December).
- 115 -
Byte 18 This byte shall specify the day of disk manufacture. This byte shall be recorded with a value in the range from 1 to 31. Bytes 19 to 22 These four bytes shall contain the Drive Serial Number (DSN) of the unit that recorded the SDI sectors. The serial number of the drive shall be represented in binary notation. Byte 19 shall contain the MSB and Byte 22 shall contain the LSB. Byte 23 This byte shall specify the Media Type. This byte shall be recorded with 0 for Type RW, 1 for Type WORM. Bytes 24 and 25 These bytes shall specify the user data capacity of the ODC in Gbytes. The capacity of the ODC shall be represented in binary notation. Byte 24 shall contain the MSB and Byte 25 shall contain the LSB. These bytes shall be set to (001E) indicating a user data capacity of 30 Gbytes per cartridge. Byte 26 This byte shall specify the sector size in user data bytes. This byte shall be recorded with a number n such that n = sector size / 1024. It shall be set to 8 indicating a sector size of 8 192 user data bytes per sector. Byte 27 This byte shall specify the Recording Track pitch in nm. This byte shall be recorded with a number n such that n = track pitch / 5. It shall be set to 80 for Type RW media indicating a Recording Track pitch of 400 nm. It shall be set to 74 for Type WORM media indicating a Recording Track pitch of 370 nm. Byte 28 This byte shall specify the nominal wavelength O of the laser in nm. This byte shall be recorded with a number n such that n = C / 5. It shall be set to 81 indicating a laser wavelength of O = 405 nm. Byte 29 This byte shall specify the nominal Numerical Aperture NA of the objective lens. This byte shall be recorded with a number n such that n = NA × 100. It shall be set to 70 indicating an objective lens with NA = 0,70. Bytes 30 and 31 These bytes shall specify the nominal cover layer index of refraction. These bytes shall be recorded with a number n such that n = index of refraction × 10 000. Byte 30 shall contain the MSB and Byte 31 shall contain the LSB of the number n. - 116 -
Byte 32 This byte shall indicate the nominal cover layer thickness in nm. Byte 33 This byte shall indicate the average cover layer thickness in nm at disk radius r = 62 mm. Byte 34 This byte shall indicate the average cover layer thickness in nm at disk radius r = 45 mm. Byte 35 This byte shall indicate the average cover layer thickness in nm at disk radius r = 28 mm. Byte 36 This byte shall specify the nominal disk rotational frequency in Hz. This byte shall be recorded with a number n such that n = rotational frequency × 4. It shall be set to 130 for Type RW media indicating a disk rotational frequency of 32,5 Hz. It shall be set to 140 for Type WORM media indicating a disk rotational frequency of 35,0 Hz. Byte 37 This byte shall specify the nominal laser read power in µW. This byte shall be recorded with a number n such that n = read power / 5. It shall be set to 100 indicating a laser read power of 500 VW. Byte 38 This byte shall specify the maximum laser read power in VW. This byte shall be recorded with a number n such that n = maximum read power / 5. This value shall be the recommendation of the media manufacturer for maximum laser read power at any radius of the disk. Byte 39 This byte shall specify the baseline reflectance R of the disk in its unrecorded initialized state as measured in a Mirror Area. This byte shall be recorded with a number n such that n = R × 100. Byte 40 This byte shall specify the change in reflectance R for user written marks. This byte shall be recorded with (00) for R mark > R space (FF) for R mark < R space Byte 41 This byte shall specify the maximum linear velocity for writing in m/s. This byte shall be recorded with a number n such that n = maximum linear velocity × 10.
- 117 -
Bytes 42 to 44 These bytes shall specify which bands of the disk can be recorded with a single pass write. This information shall be contained in a bit map where 0 1
Indicates band may be recorded in a single pass write. Indicates band requires an erase pass prior to writing.
Byte 42 Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0
ZERO ZERO ZERO ZERO ZERO ZERO ZERO Band 16
Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0
Band 15 Band 14 Band 13 Band 12 Band 11 Band 10 Band 9 Band 8
Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0
Band 7 Band 6 Band 5 Band 4 Band 3 Band 2 Band 1 Band 0
Byte 43
Byte 44
For Type WORM media, bytes 42 to 44 shall be recorded with (00). Byte 45 This byte shall specify the QWML position offset in nm. This byte shall be a signed value (- 128 to 127) denoting the physical offset of the QWML fields with respect to the midpoint of the groove centrelines in the radial direction. A positive value indicates that the QWML fields are positioned too close to the outer diameter of the disk. Bytes 46 This byte shall specify the Write Power Calibration Optimal Power Factor b, defined as the ratio: b=
Optimal Write Power Threshold Write Power
This byte shall be recorded with a number n such that n = D × 100. The Write Power Calibration Optimal Power Factor could be measured in the Write Power Calibration Zone using the 8T – 8T test pattern (see 17.3). Bytes 47 to 127 These bytes are Reserved and shall be recorded with (00).
- 118 -
Bytes 128 to 2 647 - Parameter Pages Bytes 128 to 2 647 are specifying Parameter Pages. A Parameter Page shall be 24 bytes in length and shall specify a single Write Strategy parameter (see 23.3) for 24 bands. For Type RW media, the first 17 bytes of the Parameter Page shall specify the parameter value for Band 0 through 16. The last 7 bytes shall be reserved and recorded with (00). For Type WORM media, the first 16 bytes of the Parameter Page shall specify the parameter value for Band 0 through 15. The last 8 bytes shall be reserved and recorded with (00). Page Offset 0 Page Offset 1 Page Offset 2 Page Offset 3 Page Offset 4 Page Offset 5 Page Offset 6 Page Offset 7 Page Offset 8 Page Offset 9 Page Offset 10 Page Offset 11 Page Offset 12 Page Offset 13 Page Offset 14 Page Offset 15 Page Offset 16 Page Offset 17 to 23
Parameter byte value for Band 0 Parameter byte value for Band 1 Parameter byte value for Band 2 Parameter byte value for Band 3 Parameter byte value for Band 4 Parameter byte value for Band 5 Parameter byte value for Band 6 Parameter byte value for Band 7 Parameter byte value for Band 8 Parameter byte value for Band 9 Parameter byte value for Band 10 Parameter byte value for Band 11 Parameter byte value for Band 12 Parameter byte value for Band 13 Parameter byte value for Band 14 Parameter byte value for Band 15 Parameter byte value for Band 16 for RW / Reserved = (00) for WORM Reserved = (00)
Bytes 128 to 151 This Parameter Page shall specify the nominal first pulse write power on Groove Recording Tracks P FW-G in mW. Each byte shall be recorded with a number n such that n = P FW-G × 10. Bytes 152 to 175 This Parameter Page shall specify the nominal first pulse write power on Land Recording Tracks P FW-L in mW. Each byte shall be recorded with a number n such that n = P FW-L × 10. Bytes 176 to 199 This Parameter Page shall specify the multi-pulse to first pulse write power ratio on Groove Recording Tracks P MW-G / P FW-G . Each byte shall be recorded with a number n such that n = (P MW-G / P FW-G ) × 100. Bytes 200 to 223 This Parameter Page shall specify the multi-pulse to first pulse write power ratio on Land Recording Tracks (P MW-L / P FW-L ). Each byte shall be recorded with a number n such that n = (P MW-L / P FW-L ) × 100. Bytes 224 to 247 This Parameter Page shall specify the last pulse to first pulse write power ratio on Groove Recording Tracks (P LW-G / P FW-G ). Each byte shall be recorded with a number n such that n = (P LW-G / P FW-G ) × 100.
- 119 -
Bytes 248 to 271 This Parameter Page shall specify the last pulse to first pulse write power ratio on Land Recording Tracks (P LW-L / P FW-L ). Each byte shall be recorded with a number n such that n = (P LW-L / P FW-L ) × 100. Bytes 272 to 295 This Parameter Page shall specify the erase to first pulse write power ratio on Groove Recording Tracks (P ER-G / P FW-G ). Each byte shall be recorded with a number n such that n = (P ER-G / P FW-G ) × 100. For Type WORM media, each byte is typically set to (P B-G / P FW-G ) × 100 to apply the bias power during the recording of spaces. Bytes 296 to 319 This Parameter Page shall specify the erase to first pulse write power ratio on Land Recording Tracks (P ER-L / P FW-L ). Each byte shall be recorded with a number n such that n = (P ER-L / P FW-L ) × 100. For Type WORM media, each byte is typically set to (P B-L / P FW-L ) × 100 to apply the bias power during the recording of spaces. Bytes 320 to 343 This Parameter Page shall specify the cooling pulse to first pulse write power ratio on Groove Recording Tracks (P CL-G / P FW-G ). Each byte shall be recorded with a number n such that n = (P CL-G / P FW-G ) × 100. Bytes 344 to 367 This Parameter Page shall specify the cooling pulse to first pulse write power ratio on Land Recording Tracks (P CL-L / P FW-L ). Each byte shall be recorded with a number n such that n = (P CL-L / P FW-L ) × 100. Bytes 368 to 391 This Parameter Page shall specify the bias pulse to first pulse write power ratio on Groove Recording Tracks (P B-G / P FW-G ). Each byte shall be recorded with a number n such that n = (P B-G / P FW-G ) × 100. Bytes 392 to 415 This Parameter Page shall specify the bias pulse to first pulse write power ratio on Land Recording Tracks (P B-L / P FW-L ). Each byte shall be recorded with a number n such that n = (P B-L / P FW-L ) × 100. Bytes 416 to 2 647 shall specify the write pulse timing strategy. The contents of the different time delay parameters specified by these bytes are given in table K.2 (see also Annex O). The value contained in each of these bytes shall represent a time delay ET expressed as a sum of an integer numbers m of Channel Clock period T and an integer number n of units of 1/40 of the Channel Clock period T: ET = mT + n(T/40).
- 120 -
The value of m and n shall be assigned to each byte using the following bit fields: Bit 7-6
shall represent the value m (0 to 3).
Bit 5-0
shall represent the value n (0 to 39).
Bit 7 shall be the most significant bit of value m. Bit 5 shall be the most significant bit of value n. T able K.2 – Contents of the tim e delay par am eter s us ed in the wr ite puls e s trategy Parameter
Content
TSFP
Time delay of Start First Pulse: This time defines the start location of the first write pulse of a mark. It starts 1T before the space-mark transition of the NRZ signal. It is depending on the space-mark lengths. The power level selected at the end of this time is PFW .
TEFP
Time delay of End First Pulse: This time defines the end location of the first write pulse of a mark. It starts 1T before the space-mark transition of the NRZ signal. It is depending on the space-mark lengths. The power level selected at the end of this time is PCL for 2T marks and PB for marks longer than 2T.
TX1
Time delay of Extra One: This time defines the start location of the second pulse of a write sequence (for mark at least 4T long). It starts 1T after the space-mark transition of the NRZ signal. The power level selected at the end of this time is PMP.
TX3
Time delay of Extra Three: This time defines the end location of the second pulse of a write sequence (for mark at least 4T long). It starts 1T after the space-mark transition of the NRZ signal. The power level selected at the end of this time is PB.
TSMP
Time delay of Start Multi-Pulse: This time defines the start location of the third or more inner write pulse of a mark (for mark at least 5T long). It starts at every middle T of a long mark (at 2T, 3T, 4T, . . . after the space-mark transition). The power level selected at the end of this time is PMP.
TX2
Time delay of Extra Two: This time defines the end location of the third write pulse of a mark (for mark at least 5T long). It starts 2T after the space-mark transition of the NRZ signal. The power level selected at the end of this time is PB.
TEMP
Time delay of End Multi Pulse. This time defines the end location of the third or more inner write pulse started by TSMP (for mark at least 6T long). It starts at every middle T of a long mark (at 3T, 4T, 5T, . . . after the space-mark transition). The power level selected at the end of this time is Pb.
TEMPP
Time delay of End Multi Pulse Programmable. This time defines the end location of the last inner write pulse started by TSMP (for mark at least 4T long). It starts 3T before the mark-space transition of the NRZ signal. It is depending on the mark-space lengths. The power level selected at the end of this time is PB.
TSLP
Time delay of Start Last Pulse. This time defines the start location of the last write pulse of a mark (for mark at least 3T long). It starts 2T before the mark-space transition of the NRZ signal. The power level selected at the end of this time is PLW .
TELP
Time delay of End Last Pulse: This time defines the end location of the last write pulse of a mark (for mark at least 3T long). It starts 2T before the mark-space transition of the NRZ signal. It is depending on the mark-space lengths. The power level selected at the end of this time is the final cooling power following a mark, PCL.
TECP
Time delay of End Cooling Pulse. This time defines the end location of the final cooling pulse, and starts the erase power of the space region. It starts 1T before the mark-space transition. It is depending on the mark-space lengths. The power level selected at the end of this time is PER.
- 121 -
Bytes 416 to 439 This Parameter Page shall specify the start multi-pulse delay T SMP . Bytes 440 to 463 This Parameter Page shall specify the end multi-pulse delay T EMP . Bytes 464 to 487 This Parameter Page shall specify the start extra 1 pulse delay T X1 . Bytes 488 to 511 This Parameter Page shall specify the end extra 2 pulse delay T X2 . Bytes 512 to 535 This Parameter Page shall specify the end extra 3 pulse delay T X3 . Bytes 536 to 559 This Parameter Page shall specify the end multi-pulse programmable delay of a 4T mark followed by a 2T space T EMPP (4M-2S). Bytes 560 to 583 This Parameter Page shall specify the end multi-pulse programmable delay of a 4T mark followed by a 3T space T EMPP (4M-3S). Bytes 584 to 607 This Parameter Page shall specify the end multi-pulse programmable delay of a 4T mark followed by a 4T space T EMPP (4M-4S). Bytes 608 to 631 This Parameter Page shall specify the end multi-pulse programmable delay of a 4T mark followed by a 5T or longer space T EMPP (4M-5S). Bytes 632 to 655 This Parameter Page shall specify the end multi-pulse programmable delay of a 5T or longer mark followed by a 2T space T EMPP (5M-2S). Bytes 656 to 679 This Parameter Page shall specify the end multi-pulse programmable delay of a 5T or longer mark followed by a 3T space T EMPP (5M-3S). Bytes 680 to 703 This Parameter Page shall specify the end multi-pulse programmable delay of a 5T or longer mark followed by a 4T space T EMPP (5M-4S). Bytes 704 to 727 This Parameter Page shall specify the end multi-pulse programmable delay of a 5T or longer mark followed by a 5T or longer space T EMPP (5M-5S). Bytes 728 to 751 This Parameter Page shall specify the end cooling pulse delay of a 2T mark followed by a 2T space T ECP (2M-2S). Bytes 752 to 775 This Parameter Page shall specify the end cooling pulse delay of a 2T mark followed by a 3T space T ECP (2M-3S).
- 122 -
Bytes 776 to 799 This Parameter Page shall specify the end cooling pulse delay of a 2T mark followed by a 4T space T ECP (2M-4S). Bytes 800 to 823 This Parameter Page shall specify the end cooling pulse delay of a 2T mark followed by a 5T or longer space T ECP (2M-5S). Bytes 824 to 847 This Parameter Page shall specify the end cooling pulse delay of a 3T mark followed by a 2T space T ECP (3M-2S). Bytes 848 to 871 This Parameter Page shall specify the end cooling pulse delay of a 3T mark followed by a 3T space T ECP (3M-3S). Bytes 872 to 895 This Parameter Page shall specify the end cooling pulse delay of a 3T mark followed by a 4T space T ECP (3M-4S). Bytes 896 to 919 This Parameter Page shall specify the end cooling pulse delay of a 3T mark followed by a 5T or longer space T ECP (3M-5S). Bytes 920 to 943 This Parameter Page shall specify the end cooling pulse delay of a 4T mark followed by a 2T space T ECP (4M-2S). Bytes 944 to 967 This Parameter Page shall specify the end cooling pulse delay of a 4T mark followed by a 3T space T ECP (4M-3S). Bytes 968 to 991 This Parameter Page shall specify the end cooling pulse delay of a 4T mark followed by a 4T space T ECP (4M-4S). Bytes 992 to 1 015 This Parameter Page shall specify the end cooling pulse delay of a 4T mark followed by a 5T or longer space T ECP (4M-5S). Bytes 1 016 to 1 039 This Parameter Page shall specify the end cooling pulse delay of a 5T or longer mark followed by a 2T space T ECP (5M-2S). Bytes 1 040 to 1 063 This Parameter Page shall specify the end cooling pulse delay of a 5T or longer mark followed by a 3T space T ECP (5M-3S). Bytes 1 064 to 1 087 This Parameter Page shall specify the end cooling pulse delay of a 5T or longer mark followed by a 4T space T ECP (5M-4S). Bytes 1 088 to 1 111 This Parameter Page shall specify the end cooling pulse delay of a 5T or longer mark followed by a 5T or longer space T ECP (5M-5S).
- 123 -
Bytes 1 112 to 1 135 This Parameter Page shall specify the end last pulse delay of a 2T mark followed by a 2T space T ELP (2M-2S). Bytes 1 136 to 1 159 This Parameter Page shall specify the end last pulse delay of a 2T mark followed by a 3T space T ELP (2M-3S). Bytes 1 160 to 1 183 This Parameter Page shall specify the end last pulse delay of a 2T mark followed by a 4T space T ELP (2M-4S). Bytes 1 184 to 1 207 This Parameter Page shall specify the end last pulse delay of a 2T mark followed by a 5T or longer space T ELP (2M-5S). Bytes 1 208 to 1 231 This Parameter Page shall specify the end last pulse delay of a 3T mark followed by a 2T space T ELP (3M-2S). Bytes 1 232 to 1 255 This Parameter Page shall specify the end last pulse delay of a 3T mark followed by a 3T space T ELP (3M-3S). Bytes 1 256 to 1 279 This Parameter Page shall specify the end last pulse delay of a 3T mark followed by a 4T space T ELP (3M-4S). Bytes 1 280 to 1 303 This Parameter Page shall specify the end last pulse delay of a 3T mark followed by a 5T or longer space T ELP (3M-5S). Bytes 1 304 to 1 327 This Parameter Page shall specify the end last pulse delay of a 4T mark followed by a 2T space T ELP (4M-2S). Bytes 1 328 to 1 351 This Parameter Page shall specify the end last pulse delay of a 4T mark followed by a 3T space T ELP (4M-3S). Bytes 1 352 to 1 375 This Parameter Page shall specify the end last pulse delay of a 4T mark followed by a 4T space T ELP (4M-4S). Bytes 1 376 to 1 399 This Parameter Page shall specify the end last pulse delay of a 4T mark followed by a 5T or longer space T ELP (4M-5S). Bytes 1 400 to 1 423 This Parameter Page shall specify the end last pulse delay of a 5T or longer mark followed by a 2T space T ELP (5M-2S). Bytes 1 424 to 1 447 This Parameter Page shall specify the end last pulse delay of a 5T or longer mark followed by a 3T space T ELP (5M-3S).
- 124 -
Bytes 1 448 to 1 471 This Parameter Page shall specify the end last pulse delay of a 5T or longer mark followed by a 4T space T ELP (5M-4S). Bytes 1 472 to 1 495 This Parameter Page shall specify the end last pulse delay of a 5T or longer mark followed by a 5T or longer space T ELP (5M-5S). Bytes 1 496 to 1 519 This Parameter Page shall specify the start last pulse delay of a 2T mark followed by a 2T space T SLP (2M-2S). Bytes 1 520 to 1 543 This Parameter Page shall specify the start last pulse delay of a 2T mark followed by a 3T space T SLP (2M-3S). Bytes 1 544 to 1 567 This Parameter Page shall specify the start last pulse delay of a 2T mark followed by a 4T space T SLP (2M-4S). Bytes 1 568 to 1 591 This Parameter Page shall specify the start last pulse delay of a 2T mark followed by a 5T or longer space T SLP (2M-5S). Bytes 1 592 to 1 615 This Parameter Page shall specify the start last pulse delay of a 3T mark followed by a 2T space T SLP (3M-2S). Bytes 1 616 to 1 639 This Parameter Page shall specify the start last pulse delay of a 3T mark followed by a 3T space T SLP (3M-3S). Bytes 1 640 to 1 663 This Parameter Page shall specify the start last pulse delay of a 3T mark followed by a 4T space T SLP (3M-4S). Bytes 1 664 to 1 687 This Parameter Page shall specify the start last pulse delay of a 3T mark followed by a 5T or longer space T SLP (3M-5S). Bytes 1 688 to 1 711 This Parameter Page shall specify the start last pulse delay of a 4T mark followed by a 2T space T SLP (4M-2S). Bytes 1 712 to 1 735 This Parameter Page shall specify the start last pulse delay of a 4T mark followed by a 3T space T SLP (4M-3S). Bytes 1 736 to 1 759 This Parameter Page shall specify the start last pulse delay of a 4T mark followed by a 4T space T SLP (4M-4S). Bytes 1 760 to 1 783 This Parameter Page shall specify the start last pulse delay of a 4T mark followed by a 5T or longer space T SLP (4M-5S).
- 125 -
Bytes 1 784 to 1 807 This Parameter Page shall specify the start last pulse delay of a 5T or longer mark followed by a 2T space T SLP (5M-2S). Bytes 1 808 to 1 831 This Parameter Page shall specify the start last pulse delay of a 5T or longer mark followed by a 3T space T SLP (5M-3S). Bytes 1 832 to 1 855 This Parameter Page shall specify the start last pulse delay of a 5T or longer mark followed by a 4T space T SLP (5M-4S). Bytes 1 856 to 1 879 This Parameter Page shall specify the start last pulse delay of a 5T or longer mark followed by a 5T or longer space T SLP (5M-5S). Bytes 1 880 to 1 903 This Parameter Page shall specify the end first pulse delay of a 2T mark following a 2T space T EFP (2S-2M). Bytes 1 904 to 1 927 This Parameter Page shall specify the end first pulse delay of a 3T mark following a 2T space T EFP (2S-3M). Bytes 1 928 to 1 951 This Parameter Page shall specify the end first pulse delay of a 4T mark following a 2T space T EFP (2S-4M). Bytes 1 952 to 1 975 This Parameter Page shall specify the end first pulse delay of a 5T or longer mark following a 2T space T EFP (2S-5M). Bytes 1 976 to 1999 This Parameter Page shall specify the end first pulse delay of a 2T mark following a 3T space T EFP (3S-2M). Bytes 2 000 to 2 023 This Parameter Page shall specify the end first pulse delay of a 3T mark following a 3T space T EFP (3S-3M). Bytes 2 024 to 2 047 This Parameter Page shall specify the end first pulse delay of a 4T mark following a 3T space T EFP (3S-4M). Bytes 2 048 to 2 071 This Parameter Page shall specify the end first pulse delay of a 5T or longer mark following a 3T space T EFP (3S-5M). Byte 2 072 to 2 095 This Parameter Page shall specify the end first pulse delay of a 2T mark following a 4T space T EFP (4S-2M). Bytes 2 096 to 2 119 This Parameter Page shall specify the end first pulse delay of a 3T mark following a 4T space T EFP (4S-3M).
- 126 -
Bytes 2 120 to 2 143 This Parameter Page shall specify the end first pulse delay of a 4T mark following a 4T space T EFP (4S-4M). Bytes 2 144 to 2 167 This Parameter Page shall specify the end first pulse delay of a 5T or longer mark following a 4T space T EFP (4S-5M). Bytes 2 168 to 2 191 This Parameter Page shall specify the end first pulse delay of a 2T mark following a 5T or longer space T EFP (5S-2M). Bytes 2 192 to 2 215 This Parameter Page shall specify the end first pulse delay of a 3T mark following a 5T or longer space T EFP (5S-3M). Bytes 2 216 to 2 239 This Parameter Page shall specify the end first pulse delay of a 4T mark following a 5T or longer space T EFP (5S-4M). Bytes 2 240 to 2 263 This Parameter Page shall specify the end first pulse delay of a 5T or longer mark following a 5T or longer space T EFP (5S-5M). Bytes 2 264 to 2 287 This Parameter Page shall specify the start first pulse delay of a 2T mark following a 2T space T SFP (2S-2M). Bytes 2 288 to 2 311 This Parameter Page shall specify the start first pulse delay of a 3T mark following a 2T space T SFP (2S-3M). Bytes 2 312 to 2 335 This Parameter Page shall specify the start first pulse delay of a 4T mark following a 2T space T SFP (2S-4M). Bytes 2 336 to 2 359 This Parameter Page shall specify the start first pulse delay of a 5T or longer mark following a 2T space T SFP (2S-5M). Bytes 2 360 to 2 383 This Parameter Page shall specify the start first pulse delay of a 2T mark following a 3T space T SFP (3S-2M). Bytes 2 384 to 2 407 This Parameter Page shall specify the start first pulse delay of a 3T mark following a 3T space T SFP (3S-3M). Bytes 2 408 to 2 431 This Parameter Page shall specify the start first pulse delay of a 4T mark following a 3T space T SFP (3S-4M). Bytes 2 432 to 2 455 This Parameter Page shall specify the start first pulse delay of a 5T or longer mark following a 3T space T SFP (3S-5M).
- 127 -
Bytes 2 456 to 2479 This Parameter Page shall specify the start first pulse delay of a 2T mark following a 4T space T SFP (4S-2M). Bytes 2 480 to 2503 This Parameter Page shall specify the start first pulse delay of a 3T mark following a 4T space T SFP (4S-3M). Bytes 2 504 to 2527 This Parameter Page shall specify the start first pulse delay of a 4T mark following a 4T space T SFP (4S-4M). Bytes 2 528 to 2551 This Parameter Page shall specify the start first pulse delay of a 5T or longer mark following a 4T space T SFP (4S-5M). Bytes 2 552 to 2575 This Parameter Page shall specify the start first pulse delay of a 2T mark following a 5T or longer space T SFP (5S-2M). Bytes 2 576 to 2599 This Parameter Page shall specify the start first pulse delay of a 3T mark following a 5T or longer space T SFP (5S-3M). Bytes 2 600 to 2623 This Parameter Page shall specify the start first pulse delay of a 4T mark following a 5T or longer space T SFP (5S-4M). Bytes 2 624 to 2647 This Parameter Page shall specify the start first pulse delay of a 5T or longer mark following a 5T or longer space T SFP (5S-5M). Bytes 2 648 to 8189 These bytes are Unspecified and shall be ignored in interchange. Media manufacturers may use these bytes at their discretion to record additional disk information. Bytes 8190 and 8191 These bytes shall be recorded with the SDI Identifier Complement. Both bytes shall be recorded with (2E) to indicate that this is a SDI sector.
- 128 -
Annex L (normative) Read Channel for measuring analog signals and jitter Analog signals and jitter shall be measured using the following circuit: Analog test point From read amplifier K1
Low-pass filter
Jitter test points
Equalizer
Threshold
Edge
follower
detector
Leading edge Trailing edge
Figure L.1 – Read Channel block diagram
The amplifier K 1 (see figure L.1) shall be as specified in 9.3. th
The low-pass filter shall be of the 5 Order Bessel type with a cut-off frequency equal to half the Channel clock frequency of the band being tested. The Equalizer and Threshold Follower shall be as specified in Annex N.
- 129 -
- 130 -
Annex M (normative) Timing mean and timing jitter measuring procedure The timing mean and timing jitter of leading-to-trailing or trailing-to-leading edges shall be measured using the following procedures. 1.
Set the threshold level of the detector circuit such that the 3T mark and 3T space of VFO1 are exactly 3T long.
2.
Hold the threshold level, and detect the signal edges.
3.
Measure the time intervals of the leading-to-trailing and trailing-to-leading edges using a Time Interval Analyzer.
4.
Acquire 10 independent time interval samples excluding data from defective areas.
5.
Calculate the mean value of the timing distribution of corresponding mark or space length L n . This value is the timing mean Mt.
6.
Calculate the standard deviation of the timing distribution of corresponding mark or space length L n . This value is the timing jitter Jt.
5
Mt and Jt are shown in figure M.1. The time intervals of leading-to-trailing or trailing-to-leading edges shall be separately examined, and the specifications shall be satisfied even in the worst case. In the case of Header signal evaluation of Mt(H) and Jt(H), the threshold shall be set using the 4T marks and 4T spaces in the AM and the time interval samples shall be measured using the embossed ID fields. Mean value Mt of the distribution of each nT (leading-to-trailing or trailing-to-leading edges)
Standard deviation = Jt
Time interval Ideal time interval (nT) T (Channel clock period)
Figure M.1 – Measured distribution of timing mean and timing jitter
- 131 -
- 132 -
Annex N (normative) Implementation Independent Mark Quality Determination (IIMQD) for the interchange of recorded media
N.1 Test pattern The IIMQD test uses sectors recorded with random user data patterns to test the drive’s ability to form marks of the proper length for the purposes of media interchange. Random user data patterns will include all mark and space lengths from 2T to 9T in various combinations. The following procedure shall be used to determine IIMQD for interchange of recorded media. Write several sectors on both Groove and Land Recording Tracks with random user data in each band using the laser power write method of the drive under test.
N.2 Detection method Read and detect the data signal with the following equalization coupled with detection method of detection given in 23.2.3. The threshold value may be varied in this test to compensate for the edge motion of the marks due to parameter variations. The equalizer shall be a five-tap delay line filter with tap weights values p and q: -1
-2
-3
Eq(z) = q + p z + z + p z + q z
-4
where p = + 0,1875 q = - 0,2500 -1
z = delay of T, and T is the Channel clock period for the zone being read. Measure the detected signal from the written tracks in two ways using a Time Interval Analyzer: 1.
the mean leading-to-trailing edge (mark) time intervals, and
2.
the mean trailing-to-leading edge (space) time intervals.
N.3 Measurement process 5
The measurements shall be made using 10 independent time interval samples on several tracks at each radial location. The offset for any desired run of length n is the absolute difference of the detected signal length L n minus n times T. Adjust the threshold level once for both measurements to minimize the worst case mark and space offset for this radial position and express it as a percentage of the channel bit time T.
- 133 -
N.4 Threshold follower The tracking threshold follower of figure N.1 (or equivalent) shall be used during certain signal measurements as defined in the specific test procedures. A tracking threshold filter is required to establish and maintain the signal base line for the data detection process. Its purpose is to compensate for local media variances in reflectivity, recording sensitivity, and for changes in signal d.c. level observed during the measurement process.
Positive envelope follower
Negative envelope follower
50 kHz Low-pass filter
Output
Input Comparator
Figure N.1 – Tracking threshold filter block diagram
- 134 -
Annex O (normative) Definition of the write pulse shape The waveforms of the NRZ signal and the shape of the light pulse for both Type RW and Type WORM media shall be as shown in figure O.1 (see also table K.2 of Annex K). NRZ Signal 7T
4T
2T
Shape of the Light Pulse TECP
TECP TEFP
TEMP
TELP
TEFP
TSLP
TSFP
TSFP
TELP
TECP TEFP
TSLP
TSFP PFW PMP PLW
PER
PCL PB
First Pulse
Last Pulse
Multi-Pulses Write Pulse
First
Cooling
Last
Multi-Pulse
Cooling
Write Pulse
First Cooling Write Pulse
Figure O.1 – Write pulse shape definitions
The laser power levels shown are for reference and do not imply a specific ordering of pulse power. For example, P LW may be higher than P FW , P MP may be higher than P FW , P CL may be lower than P B , etc. For Type WORM media, the erase power level P ER may be set to a lower power (i.e. same as P B ). The rise and fall times specified in 23.3.1 shall be measured as the time required to transition from the 10 % to 90 % or 90 % to 10 % points between any of the sequential optical power levels shown in figure O.1.
- 135 -
- 136 -
Annex P (normative) Asymmetry measuring definition The asymmetry of signal from user written data with mT and nT marks and spaces shall be measured based on the following definitions. See figure P.1.
mT marks and spaces
nT marks and spaces
mT marks and spaces
IH
IL
I L bot
I L top
I H bot
I H top
0 Level
Figure P.1 – Signal from user-written data with mT and nT marks and spaces
Asymmetry (mT-nT) =
1/2 [(I L top + I L bot ) – (I H top + I H bot )] I L top – I L bot
where I L and I H are the peak-to-peak values of the Read Channel signals for mT and nT marks and spaces, written under any of the conditions given in 23.3, and read under the conditions specified in 23.2. I L top , I H top , I L bot , I H bot are the top and bottom levels of I L and I H .
- 137 -
- 138 -
Annex Q (normative) Enhanced Selective Inter-Symbol Interference Cancellation (ESISIC) algorithm Data detection in the User Area shall be performed for testing purposes by the combination of the threshold detection method and so-called ESISIC (Enhanced Selective Inter Symbol Interference Cancellation) method described in this Annex. The threshold detection method is used to make a preliminary data detection decision on all data samples, but the ESISIC data detection scheme may overrule this decision. ESISIC searches for the 2T marks and spaces in the digitized readout signal from encoded data. Those samples identified as 2T marks or spaces are then considered respectively clear logical ONE's or logical ZERO's by comparing the values of digitized sample S n with adjacent data samples, as specified hereafter. Each data sample S n (see figure Q.1a) with an amplitude within the amplitude window defined by the tops and bottoms of the 3T marks and spaces in the preamble of the data sector and updated throughout the sector by the 3T tops and 3T bottoms of the Reference bytes, shall be evaluated to search for "ESISIC ONE" and "ESISIC ZERO" samples: -
Sample S n is said an ESISIC ONE if the following conditions are met: (S n > S n-2 AND S n
-
S n+2 ) OR (S n
S n-2 AND S n > S n+2 )
Sample S n is said an ESISIC ZERO if the following conditions are met: (S n < S n-2 AND S n
S n+2 ) OR (S n
S n-2 AND S n < S n+2 )
The amplitude window's condition avoids false ESISIC detection in the noisy flat parts of long marks and spaces. 1. If 2 consecutive ESISIC ONE'S are detected then those 2 Channel-bits shall be set to ONE denoting a 2T mark. Likewise, if 2 consecutive ESISIC ZERO’s are detected then those 2 Channel-bits shall be set to ZERO denoting a 2T space. This case is illustrated on the waveform of figure Q.1b which shows a possible worst-case situation, where the 2T space (samples C and D) is preceded by a long mark and the 2T mark (E and F) is followed by a long space, and which shows also a threshold level which in this (realistic) case is not controlled at the optimal level for the 2T waveforms. So in figure Q.1b, even though samples C and D are above the threshold level, they are turned into logical ZERO's by the ESISIC detection scheme. These “ESISIC ZERO's” are shown as triangles, while the “ESISIC ONE's" are shown as squares. All other samples are shown as dots. 2. If isolated ESISIC ZERO or ESISIC ONE are detected, the adjacent samples shall be further evaluated, because single 1T mark and space are illegal in the RLL(1,7) code This shall be accomplished by means of relative amplitude comparisons, independent of the slice level and independent of the absolute signal amplitude (i.e. by means of “Maximum Likelihood Detection”). This case is illustrated on the waveform of figure Q.1c where sample D is a single ESISIC ZERO (shown as a triangle) and sample F is a single ESISIC ONE (shown as a square). This means that one of the samples C, E or G should be part of a 2T mark and one of them should be part of a 2T space. The most likely resolution is determined by the amplitude differences of (C-E) and (E-G). In this case (E-G) is much larger, which makes sample G the most likely to be correct. As it is more negative it shall be considered a logical ZERO. Note that it is also clearly below the slice level, but that information is not used here. Since G is now chosen to be a ZERO, E and F shall be set to ONE and C and D shall be cleared to ZERO. - 139 -
So samples C through F shall be corrected (overruled).
Sn-3 Sn-2
Amplitude window
Sn+1 Sn+2
Sn-1
Sn Sn+3
03-0026-A
Figure Q.1a
A B C D E
F Threshold level
G H 03-0027-A
Figure Q.1b
A B C D
E
F Threshold level
G H 03-0028-A
Figure Q.1c Figure Q.1 – Example of readout waveforms and ESISIC detection
- 140 -
Annex R (normative) Requirements for interchange
R.1 Equipment for writing The disk under test shall have been written with arbitrary data by a disk drive for data interchange used in the operating environment.
R.2 Test equipment for reading R.2.1 General The read test shall be performed on a test drive in the test environment. The rotational direction and frequency of the disk when reading shall be as defined in 9.5.
R.2.2 Read Channel R.2.2.1 Charact erist ics of t he opt ical beam The optical beam used for reading shall comply with the requirements of 9.2. R.2.2.2 Read pow er The read power shall be 500 VW ± 25 VW. R.2.2.3 Read amplif ier The read amplifier after the photo detectors shall have a flat response from d.c. to 60 MHz within 1 dB. R.2.2.4 An alo g t o bin ary co n v ersio n The signals from the read amplifier shall be converted from analog to binary. The converter for the Read Channel shall work properly for signals from preformatted marks with properties as defined in clause 22. The converter for the Read Channel shall work properly for signals from user written marks with properties as defined in clause 25. R.2.2.5 Bin ary t o d ig it al co n v ersio n The binary signal shall be converted to a digital signal according to the rules of the recording codes of clause 16. The 2T marks and 2T spaces in the recording area shall be detected using the ESISIC algorithm described in Annex Q.
R.2.3 Tracking The open-loop transfer function for the axial and radial tracking servo shall be
H s (i7 ) =
1 X0 × c i7
2
i 7c X0 × i7 1+ cX 0 1+
where 7 = 2Y f , X 0 = 2Yf 0 , i=
-1
with an accuracy such that 1 + H shall not deviate more than ± 20 % from its nominal value in the bandwidth from 20 Hz to 20 kHz.
- 141 -
The constant c shall be 3. The open-loop 0 dB frequency f 0 shall be 1 700 Hz for the axial servo and 2 540 Hz for the radial servo. The open-loop d.c. gain of the axial servo shall be at least 80 dB.
R.3 Requirements for the digital read signals A byte error is defined by a byte in which one or more bits have a wrong setting, as detected by the error detection and correction circuit.
R.3.1 Sector acceptance Any sector accepted as valid during the writing process shall not contain byte errors after the error correction circuit.
R.3.2 Sector Defect Management Any sector not accepted as valid during the writing process shall have been rewritten according to the rules for Defect Management.
R.4 Requirements for the digital servo signals The focus of the optical beam shall not jump tracks unintentionally.
R.5 Requirement for interchange An interchanged optical disk cartridge meets the requirements for interchangeability if it meets the requirements of R.3 and R.4 when it is written on an interchange drive according to R.1 and read on a test drive according to R.2. Data for interchange shall be written and read anywhere within the User Area.
- 142 -
Annex S (informative) Office environment
S.1 Air cleanliness Due to their construction and mode of operation, optical disk cartridges have considerable resistance to the effects of dust particles around and inside the disk drive. Consequently, it is not generally necessary to take special precautions to maintain a sufficiently low concentration of dust particles. Operation in heavy concentrations of dust should be avoided, e.g. in a machine shop or on a building site. Office environment implies an environment in which personnel may spend a full working day without protection and without suffering temporary or permanent discomfort.
S.2 Effects of operation In the office environment (as well as other environments) it is possible for an optical disk drive to degrade the quality of the written marks if the read power is applied to a single track for a long period of time. This would happen if a media in a drive remains loaded, the drive remains in the ready status, and is in jump-back mode on one particular track. The media manufacturer’s selection of the value for the maximum read power allowed in the User Zones, as well as the optical drive manufacturer’s read power management method, should reflect this possibility and be designed to minimize any risk to data integrity.
- 143 -
- 144 -
Annex T (informative) Derivation of the operating climatic environment This Annex gives some background on how some of the conditions of the operating environment in 8.1.2 have been derived.
T.1 Standard climatic environment classes The conditions of the ODC operating environment are, with a few exceptions mentioned below, based on parameter values of the IEC standard climatic environment class 3K3 described in IEC publication 721-3-3. This publication defines environmental classes for stationary use of equipment at weather-protected locations. The IEC class 3K3 refers to climatic conditions which ". . . may be found in normal living or working areas, e.g. living rooms, rooms for general use (theatres restaurants etc.), offices, shops, workshops for electronic assemblies and other electrotechnical products, telecommunication centres, storage rooms for valuable and sensitive products."
T.2 Overtemperature considerations While IEC class 3K3 defines the limits for the room climate only, the ODC operating environment specification in this Ecma Standard takes into consideration also system and drive overtemperature. This means that when inserted in a drive, the ODC will sense a temperature which is above the ambient room temperature. The figures in the operating environment specification have been calculated from the assumption that overtemperature may be up to 20°C.
T.3 Absolute humidity The introduction of the parameter "absolute humidity (unit: g water / m 3 of air)" is very useful when studying overtemperature. When the temperature rises inside a drive, the relative humidity goes down but the absolute humidity remains substantially constant. So, making room for overtemperature in the operating environment specification affects not only the upper temperature limit but also the lower relative humidity limit. The relationship between these parameters is shown in the climatogram (the relative humidity vs. temperature map) of the ODC operating environment, figure T.1. The absolute humidity restrictions influence the operating environment in the following two ways: i. Combination of high temperatures and high relative humidities are excluded. Such combinations could have negative influence on the performance and the life of ODCs. ii. Combinations of low temperatures and low relative humidities are excluded. Such combinations are very unlikely to occur in worldwide normal office environments.
- 145 -
T.4 Deviations from the IEC standard environment class Apart from the change introduced by the overtemperature considerations above, there are a few more parameter values which are not based on IEC class 3K3. These are: -
Atmospheric pressure The IEC 3K3 lower limit of 70 kPa has been extended to 60 kPa. ODCs according to this Ecma Standard show no intrinsic pressure sensitivity and 70 kPa excludes some possible markets for ODCs.
-
Absolute humidity The IEC 3K3 value for the upper limit of 25 g/m 3 has been raised to 30 g/m 3 in view of some expected operation in portable devices outside the controlled office environment.
-
Temperature The maximum temperature around the ODC, i.e. room temperature plus overtemperature, has been limited to 55 °C (while IEC 3K3 + 20 °C would have become 60 °C). For ODCs according to this Ecma Standard, however, the 55 °C limit is considered to be a physical limit above which operation (as well as storage) is not safe. This means that equipment designers may want to ensure adequate cooling inside the drive especially when the room temperature approaches the upper IEC 3K3 limit of 40 °C.
-
Further The rates of change (the gradients) of temperature and relative humidity are not according to IEC 3K3.
T.5 Wet bulb temperature specifications Instead of specifying limits for the absolute humidity, some of the earlier standards for ODCs as well as those for other digital data storage media often use restrictions of the parameter "wet bulb temperature (unit: °C)" in order to avoid too severe combinations of high temperatures and high relative humidities. In order to facilitate comparisons between different specifications, figure T.2 and table T.1 show wet bulb temperatures of interest for the ODC operating environment, as well as for the test and storage environments. Since wet bulb temperatures vary slightly with the atmospheric pressure, the diagram is valid for the normal pressure of 101,3 kPa only.
- 146 -
Absolute air humidity (g/m 3 )
Figure T.1 - Climatogram of IEC Class 3K3 and the ODC operating environment
- 147 -
Wet Bulb temperature (°C) -20
-10
0
10
20
30
40
50
60
70
100
A B
G
90
H
Relative humidity (%)
80
70
30 g/m3 60
50
T T
I
40
30
C
20
1g/m3
F
10
D
E
0 -20
-10
0
10
20
30
40
50
60
Air temperature (°C) 95-0186-A-Revised
Figure T.2 - Wet bulb temperatures of the operating and storage environments
The points A to I and area T are defined in table T.1.
- 148 -
70
T able T .1 - Pos ition of the m ain points of Figur e T .2 Air temperature
Relative humidity
Wet bulb temperature
°C
%
°C
A
31,7
90,0
30,3
B
32,8
85,0
30,6
C
55,0
28,8
35,5
D
55,0
3,0
22,2
E
31,7
3,0
12,1
F
5,0
14,7
-1,4
G
-10,0
90,0
-10,3
H
5,0
85,0
3,9
I
10,0
46,8
-11,6
Test environment (T)
23,0 ± 2,0
50,0 ± 5,0
---
Storage environment
Region determined by A-B-C-D-E-F-G
Operating environment
Region determined by B-C-D-E-F-H
- 149 -
- 150 -
Annex U (informative) Transportation
U.1 General As transportation occurs under a wide range of temperature and humidity variations, for different periods, by many methods of transport and in all parts of the world it is not possible to specify conditions for transportation or for packaging.
U.2 Packaging The form of packaging should be agreed between sender and recipient or, in the absence of such agreement, is the responsibility of the sender. It should take account of the following hazards.
U.2.1 Temperature and humidity Insulation and wrapping should be designed to maintain the conditions for storage over the estimated period of transportation.
U.2.2 Impact loads and vibration Avoid mechanical loads that would distort the shape of the cartridge. Avoid dropping the cartridge. Cartridges should be packed in a rigid box containing adequate shock absorbent material. The final box should have a clean interior and a construction that provides sealing to prevent the ingress of dirt and moisture.
- 151 -
- 152 -
Annex V (informative) Track deviation measurement The deviation of a track from its nominal location is measured in the same way as a drive sees a track, i.e. through a tracking servo. The strength of the Reference Servo used for the test is in general less that the strength of the same servo in a normal drive. The difference in strength is intended for margins in the drive. The deviation of the track is related to the tracking error between the track and the focus of the optical beam, remaining after the Reference Servo. The tracking error directly influences the performance of the drive, and is the best criterion for testing track deviations. The specification of the axial and radial deviations can be described in the same terms. Therefore, this Annex applies to both axial and radial track deviations.
V.1 Relation between requirements The acceleration required by the motor of the tracking servo to make the focus of the optical beam follow the tracks on the disk (see 11.4.6 and 11.4.8) is a measure for the allowed deviations of the tracks. An additional measure is the allowed tracking error between the focus and the track (see 20.2.4). The relation between both is given in figure V.1 where the maximum allowed amplitude of a sinusoidal track deviation is given as a function of the frequency of the deviation. It is assumed in the figure that there is only one sinusoidal deviation present at a time.
log (x
max )
e
max
log(f )
94-0145-A
Figure V.1 - Maximum allowed amplitude of a single, sinusoidal track deviation
At low frequencies the maximum allowed amplitude x max is given by 2
x max = a max / (2Yf) ,
(1)
where a max is the maximum acceleration of the servo motor.
- 153 -
At high frequencies the maximum allowed amplitude x max is given by x max = e max
(2)
where e max is the maximum allowed tracking error. The connection between both frequency regions is given in V.3.
V.2 Reference Servo The above restrictions of the track deviations are equal to the restriction of the track deviations for a Reference Servo. A Reference Servo has a well-defined transfer function, and reduces a single, sinusoidal track deviation with amplitude x max to a tracking error e max as in figure V.1. The open-loop transfer function of the Reference Servo shall be
X0 1 H s (i7 ) = × c i7
2
i7c X0 × i7 1+ cX 0 1+
(3)
where i= -1 , 7 = 2Yf and X 0 = 2Yf 0 , with f 0 the 0 dB frequency of the open-loop transfer function. The constant c gives the cross-over frequencies of the lead-lag network of the servo: the lead break f0 and the lag break frequency f2 = f0 × c . The reduction of a track deviation x to a frequency f1 = c tracking error e by the Reference Servo is given by 1 e = x 1+ H s
(4)
If the 0 dB frequency is specified as X0 =
amax c emax
(5)
then a low-frequency track deviation with an acceleration a max will be reduced to a tracking error e max, and a high frequency track deviation will not be reduced. The curve in figure V.1 is given by
x max = e max 1 + H s
(6)
The maximum acceleration required from the motor of this Reference Servo is 2
a max (motor) = e max 7 1 + H s
(7)
At low frequencies f > f 0 / c applies
a max (motor) = a max (track) =
X 0 2emax
(8)
c
Hence, it is permitted to use a max(motor) as specified for low frequencies in 11.4.6 and 11.4.8 for the calculation of X 0 of a Reference Servo.
- 154 -
V.3 Requirement for track deviations The track deviations shall be such that, when tracking with a Reference Servo on a disk rotating at the specified frequency, the tracking error shall not be larger than e max during more than 10 Vs. The open-loop transfer function of the Reference Servo for axial and radial tracking shall be given by equation (3) within an accuracy such that |1 + H| does not differ by more than ± 20% from its nominal value in a bandwidth from 20 Hz to 150 kHz. The constant c shall be 3. The 0 dB frequency X0 shall be given by equation (5), where a max and e max for axial and radial tracking are specified 2Y in 11.4.6, 11.4.8 and 20.2.4.
V.4 Measurement implementation Three possible implementations for axial or radial measurement systems have been given below. H a is the open-loop transfer function of the actual tracking servo of the drive. H s is the transfer function for the Reference Servo as given in equation (3). x and y are the position of the track and the focus of the optical beam. e s is the tracking error after a Reference Servo, the signal of which has to be checked according to the previous paragraph.
Position sensor + y
Servo
+
x
Filter 1 1 + HS
es
ea
94-0081-B
Figure V.2 - Implementation of a Reference Servo by filtering the track position signal with the reduction characteristics of the Reference Servo
Figure V.3 - Implementation of a Reference Servo by changing the transfer function of the actual servo
- 155 -
ea
x
+
1+ Ha 1+ Hs Ha
es
y
-
94-0083-B
Figure V.4 - Implementation of a Reference Servo by changing the tracking error of the actual servo
The optimum implementation depends on the characteristics H a and H s . Good results for motors in leaf springs are often obtained by using separate circuits in a low and high frequency channel. The implementation of figure V.2 is used in the low-frequency channel, while that of figures V.3 or V.4 is used in the high-frequency channel. The signals from both channels are added with a reversed cross-over filter to get the required tracking error. In the low-frequency channel one can also use the current through the motor as a measure of the acceleration of the motor, provided the latter is free from hysteresis. The current must be corrected for the transfer function of the motor and then e e = derived from be converted to a tracking error with a filter with a transfer function a x7 2 equation (4).
- 156 -
Annex W (informative) Measurement of the vertical birefringence of the cover layer This Annex describes a non-contact measurement method for optical disk cover layer birefringence. This technique will yield average or bulk values of both in-plane birefringence (IPB) and vertical birefringence (VB) with one procedure. The method uses a slightly modified variable angle spectroscopic ellipsometer (VASE), although the variable wavelength capability is unnecessary for a simple characterization at the operating point of this Ecma Standard. The method assumes the principal optical axes of the cover layer align with the polar r, d, z directions of the disk, which is valid for the type of cover layer considered. Finally, the method described also assumes that the contribution of the ellipticity of the coated Phase Change film(s) to the measured optical retardation is negligible compared to the contribution of cover layer material. An ellipsometric measurement of the phase retardation between orthogonal polarization states for a range of incident angles is made to uniquely determine the cover layer refractive indexes for the three principal directions (N r , N d , N z ). This range of incident angles should be restricted only to limitations of the o apparatus on the low angle side, and beam walk off on the high angle side. Angles ranging from -70 to o +70 are recommended. Three angles would generally be the minimum necessary to establish VB. For a disk where the principal optical axes are aligned with the cylindrical coordinates of the disk (which is almost universally the case), the following equation expresses the retardation as a function of angle of incidence to the indexes of the disk: N r , N d , N z . The retardation data are regression fit to the non-linear analytical expression given below, and the indexes are determined as free parameters.
e = d×
Nr - sin (H ) 2
2
Nd Nz
Nz - sin (H ) 2
2
where is the retardation and d is the thickness of the cover layer. The birefringence results from the differences between the indexes In-plane:
N in = N r - N d
Vertical:
N vert = 0,5 (N r + N d ) - N z
The dimensionless birefringence can be expressed in length units by multiplying Nin or Nvert by the cover layer thickness. In this case, the birefringence is expressed as nm of retardation.
- 157 -
- 158 -
Annex X (informative) Quadrature Wobble offset control The drive system shall use the Push-Pull (PP) signal generated from the land-groove structure of the disk as the primary method of following the land and groove tracks. This Annex is describing an example of a possible use of the Quadrature Wobble marks (QWM) for controlling the eventual offset of the push-pull tracking.
X.1 Quadrature Wobble tracking offset description The QWM are incorporated into the Preformatted Headers, and are contained in the QWM field (see figure X.1). The QWM are generated by the use of Pattern A and Pattern B defined in 15.4. The 64T QWM field is divided into four 16T sub-fields denoted as S, A, B, M. These sub-fields have the following physical relationships: S Both adjacent Recording Tracks contain spaces A Only one adjacent Recording Track contains a mark B Only one adjacent Recording Track contains a mark M Both adjacent Recording Tracks contains a mark The Quadrature Wobble method uses the read signal to generate a tracking offset (TRK-OFF) signal. The relative amplitudes of marks from the two adjacent Recording Tracks are used to measure the offset from the track centreline. This method generates a tracking offset update once per sector. Eight read signal levels are sampled during each Preformatted Header. These signal levels are identified as S L , A L , B L , ML , S G , A G , B G , and MG in figure X.2. When using PP to follow a groove track, the QWM from the two adjacent land tracks (A L and B L ) are used to determine the tracking offset. The groove track centreline shall be defined as the point at which the read signal levels A L and B L are equal. Likewise, when using PP to follow a land track, the QWM from the two adjacent groove tracks (A G and B G ) are used to determine the tracking offset. The land track centreline shall be defined as the point at which the read signal levels A G and B G are equal. Signal levels S L and ML can be used to qualify the signal levels A L and B L against defects when tracking on a groove track. Likewise, signal levels S G and MG can be used to qualify the signal levels A G and B G against defects when tracking on a land track. Sampling of the eight levels can be synchronized by the detection of the AM and ID patterns of the Preformatted Header. The eight levels should be sampled near the centre of each 16T interval. The long mark and space interval of 16T is needed to allow for track-to-track misalignment of the QWM due to mastering and variations in spindle speed or eccentricity of the Recording Tracks on the disk. The read signal shown on figure X.2 is for the readout spot path shown in the figure X.1. This path is indicated by the name G even (in). This name indicates that the readout spot is following a path on groove track with an even Physical Track number. The (in) indicates that the path is not on the centreline of the groove track, but rather is too close to the inner diameter of the disk. The dashed lines of the read signal indicate data areas of the preformatted header, while solid lines indicate the read signal levels of the QWM. The relative amplitudes of the eight QWM samples and the TRK-OFF signal polarity are listed in table X.1.
- 159 -
IDL0
QWML
IDG0
QWMG
SL
AL
BL
ML
SG
AG
BG
MG
16T
16T
16T
16T
16T
16T
16T
16T
DISK OUTER L odd G odd L even G even L odd G odd L even G even
marks
DISK INNER
readout spot path
Figure X.1 - Land and Groove Quadrature Wobble Marks
space
SG
SL
AL
BL
mark
AG
BG
ML
MG
Figure X.2 – Example of read waveform (For the read out spot path "G even (in)" shown on figure X.1)
T able X .1 – Q uadr atur e W obble Rec or ding T r ac k of f s et r elations hips Recording Track (Offset)
Relationship of
Relationship of
TRK-OFF
AL and BL
AG and BG
Signal
G even (in)
AL > BL
AG < BG
–
G even (0)
AL = BL
AG < BG
0
G even (out)
AL < BL
AG < BG
+
G odd (in)
AL < BL
AG > BG
–
G odd (0)
AL = BL
AG > BG
0
G odd (out)
AL > BL
AG > BG
+
L even (in)
AL < BL
AG < BG
–
L even (0)
AL < BL
AG = BG
0
L even (out)
AL < BL
AG > BG
+
L odd (in)
AL > BL
AG > BG
–
L odd (0)
AL > BL
AG = BG
0
L odd (out)
AL > BL
AG < BG
+
Note: Assumes that the mark signal is smaller than the space signal. - 160 -
X.2 Tracking Offset Signal Calculation The tracking offset signal (TRK-OFF) can be calculated using the following method: When using PP to track on the groove: If (A G > B G )
then TRK-OFF = A L – B L else TRK-OFF = B L – A L
where the read signal level from a mark is less than the read signal from a space. When using PP to track on the land: If (A L < B L )
then TRK-OFF = A G – B G else TRK-OFF = B G – A G
where the read signal level from a mark is less than the read signal from a space. The polarity of the TRK-OFF signal has the following meaning: Negative (–)
Readout spot is too close to the inner diameter of the disk
Zero (0)
Readout spot centred on the recording track
Positive (+)
Readout spot is too close to the outer diameter of the disk
X.3 QWM Defect Qualification The S and M sub-fields of the QWM provide read signal reference levels that can be optionally used to qualify the QWM fields adjacent to the Recording Track being followed. Both the A and B read signal levels should be between the S and M reference levels. In addition, the read signal level from S should always be larger than M. A threshold value X can be applied to quantify a minimum difference between S and M, such that QWM fields that are obscured by dust or contain a defect are disqualified. The following is a suggested QWM qualification method: When using PP to track on the groove: If {(SL – ML) > X and (SL > AL > ML) and (SL > BL > ML)} then AL and BL are considered valid. When using PP to track on the land: If {(SG – MG) > X and (SG > AG > MG) and (SG > BG > MG)} then AG and BG are considered valid. It is assumed that the read signal level from a mark is less than the read signal from a space.
X.4 QWM Tracking Offset at Zone Boundaries Quadrature wobble tracking offset control cannot be used at zone boundaries due to the purposeful misalignment of the Preformatted headers. The TRK-OFF signal shall not be used to adjust offsets on groove tracks or land tracks that are adjacent to any zone boundary.
- 161 -
- 162 -
Annex Y (informative) Start Position Shift (SPS) implementation
Y.1 Start Position Shift purpose The purpose of SPS is to change the physical position of the start of recorded data to extend the cycle life of Type RW media. The rewrite cycle life of Type RW media is increased using two mechanisms. The first mechanism is to distribute the thermal shock to the recording layer near the beginning and end of the written data area. The second mechanism is to shift the position and polarity of the recorded data to minimize the effect of writing identical data patterns in the same location every time. The SPS algorithm uses two random shift values M and N and a random polarity bit P. The value of M shifts the data start position. The value of N shifts the start and end positions of the written data. The polarity of the data to be written is controlled by the value of P.
Y.2 Start Position Shift random signal generation The SPS random signal generator circuit is shown in figure Y.1. The circuit consists of a feedback shift register in which bits r 0 to r 6 are used as the value of M, r 7 to r 13 are used as the value of N, and r 14 is used as P. The shift register can be continuously clocked using the channel clock source, and the values of M, N, and P are sampled (latched) prior to writing each sector. The feedback shift register shall be initialized with all bits set to ONE. If the register is initialized with all bits set to ZERO, the register value will remain unchanged (all bits equal ZERO).
r14
r13
r12
P
r11
r10
r9
r8
r7
r6
N
r5
r4
r3
M Figure Y.1 – SPS random signal generator circuit
M = 0 to 127
Data position shift
N = 0 to127
Start position shift
P = 0 or 1
Positive / negative write polarity
+
means Exclusive-OR logical operation.
- 163 -
r2
r1
r0
- 164 -
Annex Z (informative) Sector retirement guidelines This Ecma Standard assumes approximately 36 000 sectors may be replaced in any of the following cases: -
A sector does not have at least one reliable ID field as determined by CRC.
-
A sector has a PBA that is contradictory to the one anticipated by the preceding PBAs.
-
The total number of defective bytes exceeds 228 bytes in a sector.
-
The number of defective bytes exceeds 6 bytes in any ECC interleave (codeword).
-
The number of defective Reference fields exceeds 25 in a sector.
-
For Type WORM media, the number of data transitions in the VAP field exceeds 20 in an unrecorded sector.
-
The axial tracking error exceeds acceptable limits during writing.
-
The radial tracking error exceeds acceptable limits during writing.
-
The wobble groove PLL timing error exceeds acceptable limits during writing.
- 165 -
- 166 -
Annex AA (informative) Guidelines for the use of Type WORM ODCs This Annex lists some important points to be observed when using Type WORM media specified by this Ecma Standard. a.
Read the status of the Media Sensor holes and the SDI sectors when the ODC is inserted to ascertain the media type**, so as to enable and/or disable the appropriate host commands.
b.
Read the DDS sectors to determine if the disk has been initialized. If it has been initialized, do not allow modification or amendment of the DDS. If it has not been initialized, do not allow logical block access to the WORM Zone.
c.
Before writing a sector, it must be determined whether or not the sector has already been written. This can be done by checking the VAP field for data transitions prior to writing each sector. If sufficient transitions in the VAP field are detected, the sector shall not be written.
d.
Disallow commands that can directly or indirectly alter written data such as SCSI Erase.
e.
It is recommended that SCSI Write Long and SCSI Write PBA commands be disallowed.
** NOTE Features relating to media type determination are listed in Annex BB.
- 167 -
- 168 -
Annex BB (informative) Media type identification in existing and future standards This Ecma Standard specifies cartridge features and information recorded on the disk which can be used to identify the specific types of optical disk cartridges which conform to this Ecma Standard. It is expected that other media recording layers, sector sizes, and user data capacities will be developed in the future. It is therefore recommended that the following conventions be used for these future cartridges.
BB.1 Media sensor holes Media sensor hole number 1 shall be closed for all types of Write Once Read Many recording layers. Media sensor hole number 1 shall be open for all types of Rewritable recording layers.
BB.2 PBA format and values in the Lead-out Zone Media types can be determined by parking the actuator at the inner diameter of the disk and attempting to read PBA values of sectors in the Lead-out Zone. Media type identification can be accomplished by assuming and testing each of the existing sector formats. Three pieces of format information can assist with media type identification: 1. PBA's can be properly decoded with the sector format of the assumed media type. 2. Range of PBA values at the inner diameter of the disk are consistent with the assumed media type. 3. Relationship of groove and land PBA values is consistent for adjacent Recording Tracks of the assumed media type.
BB.3 Bytes of SDI sectors Bytes 0 through 26 of the SDI sectors shall be written with values that are consistent with the definitions of this Ecma Standard. The ability to read SDI sectors without errors at the expected PBA's for such sectors is final verification of the media type.
- 169 -
- 170 -
Annex CC (informative) Laser power calibration for evaluation of media power parameters
CC.1 Variance of testing condition The laser power of the media tester should be calibrated carefully since the values of the media power parameters, defined in 23.3.1, are easily affected by the variation allowed for in the Reference Drive. The laser spot profile on the recording layer varies with the optical characteristics allowed by the Reference Drive as specified in 9.2. Table CC.1 shows the best and worst conditions allowed by the Reference Drive from the point of view of the write power sensitivity. T able CC.1 – T he bes t and wor s t c onditions allowed f or the Ref erenc e Dr ive Parameter
Best condition
Worst condition
O
405 nm
410 nm
O /NA
579 nm
586 nm
Wave front aberration
0
0,033 O rms
Disk tilt
0
2,8 mrad
Variation of the cover layer thickness
0
3 Vm
CC.2 Power calibration Laser power calibration of the tester should be done in the following manner. Use of a high-speed front power monitor is recommended for precise calibration. Step 1 Calibrate the high-speed front monitor by using a power meter (figure CC.1). -
The calibration can be done in a d.c. laser operation with a d.c. power meter.
-
For the purpose of observing the write pulse shape during writing, a high speed (>500 MHz) front power monitor is recommended.
- 171 -
Optical power meter
High-speed front power monitor ( > 500 MHz)
_._ mW
Data and servo detectors
Laser diode Oscilloscope
Figure CC.1 - Calibration of the front power monitor
Step 2 Directly observe the write pulse shape during writing (figure CC.2). -
Pulse power in focused condition is different from that in the not-focused condition because of the self coupled effect of the laser diode.
-
Pulse power levels and pulse widths should be carefully observed in real testing condition.
-
Check the power levels and timing of the pulses. Verify that the pulses correspond with the data recorded in the SDI sectors of the disk.
Disk
High-speed front power monitor ( > 500 MHz)
Data and servo detectors
Laser diode
Oscilloscope
Figure CC.2 - Measurement of pulse power and pulse width
- 172 -
Step 3 Measure the write pulse power levels and pulse widths (figure CC.3). -
Ringing can be removed by using a low-pass filter.
-
For precise pulse energy measurement, average power level measurement using a fixed pulse duty cycle is recommended.
Notes for measurement: – Disk temperature Disk temperature should be kept at the test temperature of 23 °C ± 2 °C. Internal temperature may rise for an enclosed tester. – Stray light The stray light within the optical head may enter the objective lens and form a stray beam spot. Even if the temperature increase in the optical beam is small, the measurement for the light power through the objective lens may be affected. – Contamination of optical components (especially the objective lens) If the light is absorbed by dust or other debris, the light power through the objective lens decreases. This can be measured by the power meter and does not, therefore, result in any complications. If the light is diverted instead of being absorbed, not all of the light power through the objective lens contributes to increasing the temperature at the recording layer of the media. Frequent cleaning is required for accurate results. – Beam spot size and tilt Before the measurement of media power parameters, the beam profile of the tester should be checked by optical knife edge profiler. The measured spot diameter should be near the diffraction-limited size defined by the optimum value O/NA: 579 nm of the Reference Drive. The disk tilt should also be carefully adjusted to be near zero.
- 173 -
Low-pass filter
Figure CC.3a – Elimination of ringing using a low-pass filter
Tp
T
P w = (P a vg – P b ).T /T p + P b
L o w - p a s s filte r (~ 1 0 0 k H z )
Pw
P avg
Pb
Figure CC.3b - Determination of pulse power level from average power level
Figure CC.3 - Determination of pulse power levels
- 174 -